Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE MAJESTIC Builder Name: Street: THE MAJESTIC U� G Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, �- `O Permit Number: Owner: WYNNE DEV. Jurisdiction: Design Location: FL, Fort Pierce �a� �G County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1512.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1128.00 ftZ b. Frame - Wood, Exterior R=11.0 384.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1608.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1608.00 ftZ 6. Conditioned floor area above grade (ftZ) 1608 b. N/A R= ftz Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 11. Ducts R ftZ 7. Windows(141.9 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=0.54 101.94 ftZ SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.254 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1608.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1608.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 15. Credits Pstat Glass/Floor Area: 0.088 Total Proposed Modified Loads: 50.22 PASS Total Baseline Loads: 50.28 I hereby certify that the plans and specifications covered by Review of the plans and t%E SrATF this calculation are in compliance with the Florida Energy specifications covered by this D� Code. calculation indicates compliance �� �i„��'' "'°.•`` awn with the Florida Energy Code. PREPARE Y. DATE-1MA4EM Before construction is completed this building will be inspected for compliance with Section 553.908 * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. WE OWNER/A BUILDING OFFICIAL: DATE: n.DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/27/2018 1:24 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT 5UMMARY CHF-GKLI51 RtPUK PROJECT Title: WYNNE THE MAJESTIC Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1608 Lot # Owner Name: WYNNE DEV. Total Stories: 1 Block/Subd!vision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 225 Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1608 12864 SPACES Number Name 'Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 238 1904 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 589 4712 No 0 1 Yes Yes Yes 8 KITCHEN 228 1824 Yes 0 1 Yes Yes Yes 9 BATH 2 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 82 656 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 38 ft 0 238 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 6/27/2018 1:24 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT 5UMMAKY GHF-UKLlb I KtPUK I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 589 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 12 ft 0 228 ft2 -_-- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 2 5 ft 0 50 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 82 ft2 ---_ 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1695 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1608 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 238 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 589 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 228 ft2 0.1 Wood 9 Under Attic (Vented) BATH 2 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 82 ft2 0.1 Wood WALLS ()rot Adjacent Space Cavity Width To AAWI T44peR_VaI11P In Ft Height Et In Area Sheathing Framing RA/al-le Fraction Solar Ahqnr Below Grade% 1 NE=>W Exterior Concrete Block - Ext.IndMASTER BE 4.1 17 0 8 0 136.0 ft2 0 0 0.5 0 2 SW=>E Exterior Concrete Block - Ext IndMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 3 NW=>S Exterior Concrete Block - Ext IndMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 4 NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 _ 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block - Ext InMNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block - Ext IndANING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 6/27/2018 1:24 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM RAnr,_9nl7 INPUT SI IMMARY CHF(-KLIST RFP()RT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt In Wall lype Space ile Et n Et rea9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.5 0 13 N=>SW Exterior Frame - Wood MASTER BE 11 26 8 208.0 ft2 0.23 0.5 0 14 E=>NW Exterior Frame - Wood MASTER BE 11 11 8 88.0 ft2 0.23 0.5 0 15 W=>SE Exterior Frame - Wood MASTER BE 11 11 8 88.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .28 3 3. 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V . # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 N 16.4 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 20.6 ft2 1 ft 0 in 1 ft 4 in None None 5 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 25.1 ft2 1 ft 0 in 1 ft 4 in None None 6 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft2 9 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1040 ft2 1040 ft2 48 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1500.8 82.39 154.95 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 6/27/2018 1:24 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply --- V -- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ft2 Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinHJan HFeb Mar Mar Apr Apr May May Jul [ ] Jun Jul [X] Jun rl X Aug AuSep Se Oct Nov Oct Nov ki Dec Dec H Ventin Jan Feb X Mar A r Ma [ ] Jun Jul [ Aug L Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING/GREAT R Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft.- ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/s .ft. ft2 ft 0.3 FOYER Name: Test Rater Rating Compant: Test Rater Date: LQ 4-)AZ 6/27/2018 1:24 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MAJESTIC Builder Name: Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE DEV. Jurisdiction: W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind popong and wirmna.. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire spripkl�r cover plates and walls or ceilings a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/27/2018 1:24 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1608 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.9 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: ��- Date: \'-k ---\o �,- Address of New Home: THE MAJESTIC City/FL Zip: FT. PIERCE, FL S 6/27/2018 1:24:20 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Job: pro ect Summary Date: wrightsoft� Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AQL.COM For. THE MA DES. FILE THE MAJESTIC F .PIERCE, FL COPY ��� Notes: Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Fort Pierce, FL, US Summer Design Conditions Outside db .90 75 °F Inside db Design TD 15 'F Daily range Relative humidity 50 61 r/Ib Moisture difference g Sensible Cooling Equipment Load Sizing Structure 17339 Btuh Structure 17020 Btuh Ducts 5899 Btuh Ducts 8920 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23239 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 24643 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3339 Btuh Ducts 2433 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 1608 1608 Equipment latent load 5772 Btuh Volume (ft3) 13924 13924 Air changes/hour 0.38 0.20 Equipment total load 30415 Btuh Equiv. AVF (cfm) 88 46 Req. total capacity at 0.70 S H R 2.9 ton Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 Btuh @ 470F 27 OF 1160 cfm 0.050 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Both Actual air flow 1160 cfm Air flow factor 0.045 cftiVBtuh Static pressure Load sensible heat ratio 0.50 0.82 in H2O Calculations approved byACCA to meet all requirements of Manual J 8th Ed_ . + wrilghtsoft` Right -Suite® Universal 2017 17.0.14 RSU08101 ACCA ...k CalcsMocuments\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N - - wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Ecposed wall 141.0 ft 46.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 294.0 ft 5 Room area 1608.0 ft2 294.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4bcs 0.143 ne 4.00 2.55 454 408 1634 1039 56 56 224 - 143 Z. 4A5-2om 0.770 'ne 21.56 36.90 21 0 446 764 0 0. .0 0 4A5-2om 0.770 1 ne- 21:56 36.90 25 0 543 930 0 0 0 . 0 13A-4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11 11D0 0.390 se 10.92 11.31 23 23 248 257 0 0 0 0 y/ ��--G 13A�4ocs.• 0.143 sw: 4.00 2.55 392 369 1476 939 .200 200 801 509 . 9A-c1om` •. 1270 -"sw .35.56 42:91 7 5 _ ,247 298 .0 :0, ...0 0 r �,1Ac1om 1.210 sw 35.56. 54.02' 16 8 581 883 .0 • 0 0 - • 0 �1 {--G 13A4ocs 0.143 nw 4.00 2.55 308 235 939 597 112 79 318 202 1A-c1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 • P, ' 12C-09w 0.091 - 2.55, 1:28 376 376 958 482 - 0 0 :; 0 0 C 16A 30md 0.032 - 0.90 2.32 1608 1608 1441 3731 294 294 263 682 F ; : ": 22A tpI 0.989 - 27.69 . 0.00 1608 141 3905 0 .294' 46 1274 _ 0 6 c)AED exursion 1638 729 Envelope loss/gain 14626 14645 4042 3743 12 a) Infiltration 2714 765 820 231 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 7 1610 1 230 Appliancestother 0 0 Subtotal Vines 6 to 13) 17339 17020 4862 4205 Less eidemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17339 17020 4862 4205 15 Duct loads 34% 52% 5899 8920 34% 52% 1654 2204 FTTotal room load I 23239 25941 6516 6408 Air required (cfm) 1160 1160 325 287 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 1 ... k Calcs\Documents\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N +� wrightsoft Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST..LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 E)(posed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft2 61.0 ft2 Ty . Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh1ft2-°F) (Btuh/ft1) 1 or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13A4ogs 0 143 ne 4.00 255 . 0 0 0 0 0 0 0 A 4 tom 0 770 ' ne 21.56 : 36.90 : U > 0 . 0 , '0 0 ' : 0 4A5-tom 0.77,0 : ne. 21.56 36.90 0 0 0. 0 0 0. 0:. 0 V!/ 13A-1ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 t-D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A flocs 0143 sw 4:00 2.55 °. 0 0 . 0 ;- 0 56 49 196 , 125: 1Ac1om 1 270 `sw 35:56 42.91 0 � . 0 0 : 0 : 7 5 247 : `298: 1Ac1om. 1 270 sw 3556 . 54.02 • . 0 A . 0 0 0 0. 0 -0 yJ 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 Welom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 L�_GG 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 0.091 ' = 2.55 .1.28 0 0 0 0 0 .0 "' 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 F '"'= 22Atpl •:. 0.980 : -' 27.69 ': 0.00 63 0 0 : 0 " " 61' 7• . `194 6 c)AED excursion 0 Envelope loss/gain 56 146 1 692 798 12 a) Infiltration b) Room ventilation ' 0 6 125 35 0 0 13 Internal gains: Occupants @ 230 p 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 56 146 ale 833 Less edemal load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 34% 52% 79 1 34� 52% 216 433 Total room load 1094 Air required (cfm) 76 223 1269 4 10 55 57' Calculations a roved b ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Apr-11 09:28:74 �A Right -Suite® Universal 2017 17.0.14 RSU08101 ...k CalcsIDOCUments%WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N Page 2 -- wrightsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: By: 1 Room name LAUDRY BEDROOM 2 2 F)osed wall 0 ft' 12.0 ft 3 Room height 8.0 ft healfcool 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0 ft 5 Room area 36.0 ft2 180.0 ft2 Ty Construction number U-value (Btuh/f?2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -W 13AAocs 0.143 ne 4.00.. 255 0 0 0 0 0 0 0 0 4A5 tom 4A5-2om 0.770 0.770 ne -ne 21.56 21.56 36.90 36.90 0 : 0 0 0 0 0 01 0 0 0 0. 0 0 0' 0 0 11 V�/ LD 11D0 0.143 0.390 se se 4.00 10.92 2.55 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 --13A-4ocs 13AAocs 1A-c1om ' liNc1om 0:143 1.270 1.270 sw sw 'sw: 4.00 35.56 35.56 2:55. 42.-91' , '54.02 0 ' 0 0 0 .. 0 0 to .0,-. - 0 0 0, ' 0 96.--, ` 0 . 16 .80 0 - 8 319 0. 158.1 203 0. .883 13Ar4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56. 45.24 0 0 0 0 0 0 0 0 4A5-2omd '12C-0sw ` 0.770 0:091 . nw 21.56 2:55 36.90 .1.28 0 0 0 0 0 0 0 0 0 104 0 :. ' 104 0 ` 265 0 133 P. C 16A-30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 418 F- '- `22A-tpl :. 0.989 21.69 0:00 36 0 0 . 0 : 180 12. 332 0 6 c)AED excursion 0 507 Envelope loss/gain 32 84 1659 2143 12 a) Infiltration 0 0 214 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 132 84 1873 2204 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 15 6 15 14 Subtotal 38 98 1878 2218 15 Ductloads 34% 52% 13 51 340/6 52% 639 1162 Total room load 51 149 1 2517 3381 Air required (cfm) 1 13 7 1126 151 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 :28:14 3 k CalcslDocumentslWYNNE-MAJESTIC MOD EL-1 608. rup Calc = MJ8 Front Door faces: N 9 - - wrightsoftRight-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a,10L.COM 1 Room name DINING/GREAT ROOM KrrCHEN. 2 EVosed wall 50.0 ft 12.0 ft 3 Room height 9.8 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 589.0 ft 589.0 ft' 19.0 x 12.0 ft 228.0 ftz Ty Construction U-value Or HTM Area (ft-) Load Area (ft') Load number (13tuh/ftZ- °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat 7CO01 Gross N/P/S Heat Cool Gross NIP(S Heat Cool 6 1 13A4ocs 0.143 ne 4.00. 2.55 294. 248 993 632 96 96 384 244 4A5-2om ... AA5.2om 0.770 . 0.770 ne ne 21.56 21.56.- 36M 36.90 21 25 0 0 446 543 764 . .930 0 0 0. 0 :0 0 _. 0 D VI✓ 11 13A-4ocs 11D0 0.143 0.390 _ se se 4.00 10.92 2.55 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -D 13A11ocs 1A clom ' 1Ac1om, : 0.143 1.270 1 270.:sw' sw . sw, .4.00. 35.56 35.58 2.55 42.91 . 54.02 0. 0 0 0 0 0 0 0 0. 0 .. 0 0 0 0 0 0 ' :: 0 0 "0 . -',0 0. 0 0- 0 V♦!! 13A-4ocs 0.143 nw 4.00 2.55 196 155 621 395 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 IF--�G; Ti 4A5-2omd `:12C Osw, _` 0.770 0.091 nw .- 21.56 2.55 36.90 -1.28 41 0 0 . 0 880 0:- 1505 0- 0 104 0 '" 104 0 . 265, 0 . - . 133 C 16A-30md 0.032 - 0.90 2.32 589 589 528 1366 228 2A8 204 529 22A tpI . 0.989 :: - 27.69 0.00 589 . .50 1385 '. ' --0 228 12 `332 .:. "0 6 c)AED excursion 168 0 Envelope loss/gain 5396 5760 1186 907 12 a) Infiltration 1092 308 214 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 6488 6988 1400 1427 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 6 6494 15 7002 0 1400 0 1427 15 Duct loads 34% 52% 2209 3670 34% 52% 476 748 Total room load 177 8703 10672 1876 2175 Air required (cfm) 434 477 94 97 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 15P. - wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4 ...k Calcs\Documents\WYNNE-MAJESTIC MODEL-1608.rup Cale =MJ8 Front Door faces: N 9 Orr x m_ ee 0 O J rt N N < 0 <, z m D� m» •O_I c O OC O= m ry rn m WN O 0 0 (D N Z V 0 V a n 0) C �1 7 in L pl A W N p� CA CAA to" DUFF Oti,yN 3 SS8 8 O �7 0 N m as8 rnn�DDwyy'>w�wpADw (� 80 3 a w om _� 3 n �S 3 Lf �3 o� � n ��' m S➢ 7 Y'h➢h';h'DCo➢Y'V'➢ G7�N> NN 7 8?m m a o rA 8 O CDC c �' �? toCD 0000>o�- o0000o (ON �'OOWO O.W.000W c CDCD CD77 V.CO(ppN�Wppp,CT OlA OA N ca O pp - COD O(OJI m WOS):0)S N 00 M cr2 - NN,»OA�ON �CINR $ pO8�8O,N co (M PR ccil N'� CDOSao o000800000 O O .D 0 G1 OOO OO OO.O OO Ooo W x O 1 2 CDO O N (OV (D CA00 OD W (OD C�.a� Gj ( �7ap OO C1f00000'0000000 S ca OON WO(7100 A 00 OCNII OD O O(A O.O OO OON00000 A N ry 61 o .. ^N'cN»OOQOOOo.oOOOo 3'� N 0 0 Z M m x o N - OCn000000000000 x 2 S x CA o oo. oo�oo .�i Ooi�i N :, ON0000'0,0;00000.0. _ �� �R 0o OONOO W o0 00 to O _, � „ ONOO oo 00000000 m D _C 0 0 C) (A 0 0 H O z d C m.. + wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946.Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a,10L.COM 1 Room name FOYER 2 E)posed well 9.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 1.0 x 82.0 ft 5 Room area 82.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 N 13A4ocs '. 0.143 -.ne 4.00 2.55 8 8 32 20 4A5.2om 0.770 --ne :21.56 36.90 0 0 0 ,0 4A529m. 0.770 ne 21.56 36:90: .0 0 0 ..0 .. V►/ 13A-4ocs 0.143 se 4.06 2.55 64 41 165 105 11 t-D 11DO 0.390 se 10.92 11.31 23 23 248 257 V�l�--G 13AAocs . 0.143 sw : 4.00 - . 2.55 0 ,.0 . 0 .. 01. 1Ac1om : 1.270 sw:_; 35.56 42:91' - 0 0 0 0 ' G '9Aclom : 1.276 sw>, 35M. _ 54M 0 ' 0 0 > 0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 1A-clom 1.270 nw 35.56 45.24 0 0 0 0 4A5.2omd :12C-Osiii: 0.770 0:091 nw .- 21.56 2.56 36.90 1.28 0 168 0 168 0 428 0 216 P_ C 16A30md 0.032 - 0.90 2.32 82 82 73 190 F ' -22A-tpl''; 0.989 - - - 27.69 - MO 82 9 249 •. 0 6 c)AED moursion 0 Envelope loss/gain 11% 788 12 a) Infiltration 160 45 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 1357 834 Less e)demal.load 0' 0 14 Less transfer Redistribution Subtotal 0 0 1357 0 0 834 15 Duct loads 34% 52% 462 437 Total room load 1818 1271 ir required (cfm) 1 191 57 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. A&A `FP- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr 11 0 :28: ... k Calcs\Documents\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N' Page 6 G Duct S stem Summary Job: -- wrightsoft, y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466-6796 Email:_ QUICKCALCS@AOL.COM Ploject Intormation For: WYNNE DEV. THE MAJESTIC, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (fEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.266 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250-/ 0.250 in H2O 0.266 in/100ft 1160 cfm 188 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (In) H x W (in) Duct Matl Actual Lin (ft) Ftg.Egv . Ln (ft) Trunk BATH h 587 29 18 0.359 4.0 Ox0 VIFx 24.3 115.0 st1 BEDROOM 2 c 3381 126 151 0.372 7.0 Ox 0 VIFx 19.4 115.0 st1 DINING/GREAT ROOM C 3558 145 159 .0.351 7.0 OxO VIFx 27.5 115.0 SO DINING/GREAT ROOM -A C 3557 145 159 0.287 7.0 OxO VIFx 39.4 135.0 st1 DINING/GREATROOM-B C 3557 145 159 0.277 7.0 Ox0 VIFx 45.2 135.0 st1 FOYER h 1818 91 57 0.515 4.0 Ox 0 VIFx I 2.0 95.0 KITCHEN C ,2175 94 97 0.377 6.0 Ox0 VIFx 17.6 115.0 st1 LAUDRY C 149 3 7 . 0.359 4.0 OxO VIFx 24.3 115.0 st1 M. BATH C 1269 55 57 0.274 4.0 Ox0 VIFx 47.4 135.0 st1 MASTER BEDROOM h 3258 163 143 0.266 7.0 Ox 0 VIFx 52.9 135.0 st1 MASTER BEDROOM -A h 3258 163 143 0.276 7.0 OxO VIFx 46.1 135.0 st1 wlc c 223 4 10 0.287 4.0 Ox0 VIFx 39.0 135.0 st1 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 Peak AVF 1069 -1103 0.266 1032 14.0 0 x 0 VinlFlx 1 wri htsoft° 2017-Apr-1109:28:15 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 1 k CalcslDocuments\WYNNE-MAJESTIC MOD EL-1 608. nip Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in). Duct Matl Trunk rb1 OxO. 1160 1160 0 0 0 0 Ox 0 VIFx " wrightsoft° Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:28:15 Page 2 ... k CaIcslDocumentslWYNNE-MAJESTIC MODEL-1608.rup Calc = MJB Front Docr faces: N