HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM ,R405-201.7
FLORIDA ENERGY EFFICIE CIA/FOR BI
Florida Department of Business and Professional Reaulation -
Project Name: SEDONA DEVELOPMENT 3170-3180
Street: 3170-3180 MORNINGDEW LANE
`City; State, Zip: FT. PIERCE, FL,
Owner.
Design Location: FL, Fort Pierce
1. New construction or existing
2. Single family or multiple family
P
3. Number of units, if multiple family
4. Number of Bedrooms
5. is this'a worst casd?
6. Conditioned •floor•.area above grade (ftz)
Conditioned floor. -area below grade (ftz)
7. Windows(390.0 sgft.) Description
a. U-Factor. Dbl, U=0.65
SHGC: SHGC=0.25
b. U-Factor. Dbl, U=0.60
SHGC SHGC=0.25
c. U-Factor: WA
SHGC:I
d. U-Factor N/A
SHGC:: I
Area Weighted Average Overhang Depth:
.Area
Weighted Average SHGC:
S. Floor Types' (4044.0 sgft.)
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
Multi -family
6
12
No
4044
0
Area
240.00 ftz
150.00 ftz
ftz
ftz
1.000 ft.
0.250
Insulation Area
R=0.0 4044.00 ftz
R= ftz
R= ftz
Builder Name:
Permit Office:
Permit Number:
Jurisdiction:
County::
ILDING CONSTRU
'. LUCIE COON APR 12 2018
ST. Lucie County, Permitting
Lucie (Florida Climate Zone 2 )
9. Wall Types (6420.0 sgft.)
a. Concrete Block - Int Insul, Exterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types ( 04E
a. Under Attic (Vents
b. N/A
c. N/A
11. Ducts
3 additional duct sysi
b. Sup: Attic, Ret: Al
c. Sup: Attic, Ret: Atl
12. Cooling systems I
a. Central Unit
b. Central Unit
3 additional cooling s
13. Heating systems
a. Electric Strip Heat
b. Electric Strip Heat
3 additional heating E
14. Hot water systems
a. Electric
b. Conservation
None
15. Credits
sgft.)
AH: UNIT 1
AH: UNIT 1
Insulation Area
R=4.1 6420.00 ftz
R= ft'
R= ftz
R= ftz
Insulation Area
R=30.0 4046.00 ftz
R= ftz
R= ftz
R ftz
6 135
6 135
(see detail
kBtu/hr Efficiency
18.8 SEER:16.00
18.8 SEER:16.00
(see details)
kBtu/hr Efficiency
17.0 COPA.00
17.0 COPA.00
(see details)
Cap: 40 gallons
EF: 0.950
CF, Pstat
I Glass/Floor Area: 0.096 Total Proposed Modified Loads: 149.46 I PASS
Total Baseline Loads: 157.42
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliai
with the Florida Energy Code
PREP vY:. Before construction is comple
DATE: this building will be inspected
compliance with Section 663.
I hereby certify that is ilding, as designed, is in compliance Florida Statutes.
with the Florida E rg o
OWNER BUILDING OFFICIAL: -
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler encl
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4C
enveldpe 1eekags test report with envelope leakage no greater than . 00 1450
qualifies as
I.I. and this project requires an
4111/2b1812:24 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software I Page 1 of 6
FORM R405-2017
PROJECT
Title: SEDONA DEVELOPMENT
3 Bedrooms: 12
Address Type:
Street Address
Building Type: User
Conditioned Area: 4044
Lot #
C,emer Name:
Total Stories: 1
Block/Subdivision:
# of Units: 6
Builder Name:
Worst Case: No
PlatBook:
'Permit Office: ST. LUCIE COUNTY
Rotate Angle: 0
Cross Ventilation: No
Street:
3170-3180 MORNINGD
Jurisdiction:
Family Type: Multi -family
Whole House Fan: No
County:
City, State, Zip:
St. Lucie
FT. PIERCE,
New/Existing: New (From Plans)
FL ,
Comment:
I
CLIMATE
;
Design Location
Design Temp
TMY Site
Int Design Temp Heating
Design Daily Temp
97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO BEACH_MUNI 39 90
70�;
75 299
62
Low
BLOCKS
'I
Number Name
Area Volume
1 I Blockl
688 6880
2 1 Block2
667 6670
- 3 Block3
667 6670
4 Block4
1334 13340
-5 Blocks
688 6880
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 UNIT 1
688 6880 Yes 2
2
1 Yes
Yes
Yes
2 UNIT2
667 6670 No 2
2
1 Yes
Yes
Yes
3 UNIT 3
667 6670 No 2
2
1 Yes
Yes
Yes
4 UNIT 4 AND 5
1334 13340 No 2
4
1 Yes
Yes
Yes
5 UNIT 6
688 6880 No 2
2
1 Yes
Yes
Yes
FLOORS
'
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist'R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
UNIT 1 125 ft 0
688 ft2
1 0
0
2 Slab -On -Grade Edge Insulatio
UNIT 2 125 ft 0
667 fta
0 0
1
3 Slab -On -Grade Edge Insulatio
UNIT 3 125 ft 0
667 ftz
1 0
0
4 Slab -On -Grade Edge Insulatio
UNIT 4 AND 5 250 ft 0
1334 ft'
_
1 0
0
5 Slab -On -Grade Edge Insulatio
UNIT 6 125 ft 0
688 fta
0
0
4/11/2018 12:24 PM • EnergyGauge® USA - F1aRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017.
6 ''
ROOF
/
Roof
Gable
Roof Solar SA
Emitt
Emitt
Deck
V
#
Type Materials Area
Area
Color Absor. Tested
Tested
Insul.
1
Gable or shed Composition shingles 4380 ft2
842 ftz
Light 0.6
No
0.9
No
0
21
`
ATTIC
1
- V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
300
4044 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) UNIT 1
30
Blown
688 ft2
0.11
Wood
2
Under Attic (Vented) UNIT 1
30
Blown
668 ft2
0.11
Wood
3
'Under Attic (Vented) UNIT 1
30
Blown
668 ft2
0.11
Wood
4
Under Attic (Vented) UNIT 1
30
Blown
1334 ft2
0.11
Wood
5
Under Attic (Vented) UNIT 1
30
Blown
688 ft2
0.11
Wood
WALLS
_
1
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar
Below
0
- 1
N
Exterior Concrete Block - Int Insul UNIT 1
4.1 16
10
160.0 ft2
0
0
0.5
0
--2
E
Exterior Concrete Block - Int Insul UNIT 1
4.1 45
10
450.0 ft2
0
0
0.5
0
3
S
Exterior Concrete Block - Int Insul UNIT 1
4.1 16
10
160.0 W
0
0
0.5
0
-4
W
Exterior Concrete Block - Int Insul UNIT 1
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 5
N
Exterior Concrete Block - Int Insul UNIT 2
4.1 16
10
160.0 ft2
0
0
0.5
0
- 6
E
Exterior Concrete Block - Int Insul UNIT 2
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 7
N
Exterior Concrete Block - Int Insul UNIT 2
4.1 16
10
160.0 ft2
0
0
0.5
0
_ 8
W
Exterior Concrete Block - Int Insul UNIT 2
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 9
N
Exterior Concrete Block - Int Insul UNIT 3
4.1 16
10
160.0 ft2
0
0
0.5
0
10
E
Exteror Concrete Block - Int Insul UNIT 3
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 11
S
Exterior Concrete Block - Int Insul UNIT 3
4.1 16
10
160.0 ft2
0
0
0.5
0
__ 12
W
Exterior Concrete Block - Int Insul UNIT 3
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 13
N
Exterior Concrete Block - Int InstdNIT 4 AND
4.1 32
10
320.0 ft2
0
0
0.5
0
_ 14
E
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 45
10
450.0 ft2
0
0
0.6
0
_ 15
S
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 32
10
320.0 ft2
0
0
0.5
0
16
W
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 17
N
Exterior Concrete Block - Int Insul UNIT 6
4.1 16
10
160.0 ft2
0
0.6
0
_ 18
E
Exterior Concrete Block - Int Insul UNIT 6
4.1 45
10
450.0 ft2
0
0.5
0
_ 19
'S
Exterior Concrete Block - Int Insul UNIT 6
4.1 16
10
160.0 fix
0
0.5
0
20
W
Exterior, Concrete Block - Int Insul UNIT 6
4.1 45
10
450.0 ft2
0
0.6
0
4/11/201812:24 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R4Ub-ZU1 I
`
DOORS
1
#
Ornt Door Type
Space
Storms
U Value
Area
Ft
In
In
FHeightln
9
N Insulated
UNIT 1
None
.37 3
6 8
20 ft2'
2
N Insulated
UNIT 2
None
.37 3
6 8
20 ft2
3
S Insulated
UNIT 3
None
.37 3
6 8
20 ft2
4
W Insulated
UNIT 4 AND
None
.37 3
6 8
20 ft2
5
W Insulated
UNIT 4 AND
None
.37 3
6 8
20 ft2
6
S Insulated
UNIT 6
None
.37 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
'Wall
Overhang
# Ornt ID Frame Panes
NFRC
U-Factor SHGC
Imp
Area Depth
Separation
Int Shade
Screening
1
N 1 Metal Low-E Double
Yes
0.65 0.25
N
40.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
2
S 3 Metal Low-E Double
Yes
0.6 0.25
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapesiblinds
- None
3'.
W 4 Metal Low-E Double
Yes
0.6 0.25
N
15.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
4 '
N 5 Metal Low-E Double
Yes
0.65 0.25
N
40.0 ft2 1 It 0 in
1 ft 4 in
Drapes/blinds
None
5
N •7 Metal Low-E Double
Yes
0.6 0.25
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
6•
N 9 Metal Low-E Double
Yes
0.65 0.25
N
40.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
7 '
S 11 Metal Low-E Double
Yes
0.6 0.25
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
8 I
N 13 Metal Low-E Double
Yes
0.65 0.25
N
80.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
9
S 15 Metal Low-E Double
Yes
0.6 0.25
N
40.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
10
N 17 Metal Low-E Double
Yes
0.65 0.25
N
40.0 ft2 1 It 0 in
1 ft 4 in
Drapes/blinds
None
11
E 18 Metal Low-E Double
Yes
0.6 0.25
N
15.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
12
S 19 Metal Low-E Double
Yes
0.6 0.25
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000445
4718 259.01
487.11 .3247
7
HEATING SYSTEM
1 #
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
17 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COPA
17 kBtu/hr
2
sys#2
- 3
Electric Strip Heat/
None
COP:1
17 kBtu/hr
3
sys#3
5
Electric Strip Heat/
None
COP:1
17 kBtu/hr
5
sys#5
4 A
Electric Strip Heat/
None
COP:1
17 kBtu/hr
4
sys#4
4 B
Electric Strip Heat/
None
COP:1
17 kBtu/hr
4
sys#4
4/11/201812:24 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Du,
1
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm
0.8
1
sysi
2
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm
0.8
2
Sys#,
3
Central Unit/
None
SEER: 16 18.8. kBtu/hr
564 cfm
0.8
3
sys#3
5
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm
0.8
5
sys#5
4 A
Central Unit/
None
SEER: 16 18.8 kBtu/hr
564 cfm
0.8
4
sys#4
" n o
/n.....—I 1 LJLJ
AI......
CCCD• 4R 40 Q
ARA nfm
n A
A
eue4FA
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF Cap
Use
SetPnt Conservation
1 Electric
None
UNIT 1
0.95 40 gal
130 gal
120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert #
Company Name
System Model # Collector Model
# Area Volume
FEF
None
None
ft2
DUCTS
- /
— Supply —
---- Return —
Air
CFM 25 CFM25
HVAC #
V
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT QN RLF
Heat
Cool
1
Attic
6 135 ft2
Attic
35 ft2 Default Leakage
UNIT 1
(Default) (Default)
1
1
2
Attic
6 135 ft2
Attic
35 ft2 Default Leakage
UNIT 1
(Default) (Default)
2
2
3
Attic
6 135 ft2
Attic
35 ft2 Default Leakage
UNIT 1
(Default) (Default)
3
3
4
Attic
6 260 ft2
Attic
65 ft2 Default Leakage
UNIT 1
(Default) (Default)
4
4
5,
Attic
6 135 ft2
Attic
35 ft2 Default Leakage
UNIT 1
(Default) (Default)
5
5
TEMPERATURES
Programeble Thermostat: Y
Ceiling Fans:
Heating
EX Jan
Feb
pC] Mar
E Apr
f May Jun Jul
Aug
rl
�X]Sep Oct Nov
OctX Nov
Dec
Dec
Venting
[[ Jan
Feb
[X Mar
(Xj
[ Jun Jul
Aug
Sep
4/11/2618 12:24 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 6 of 6
i
FORM R405-2017
Thermostat Schedule:
HERS 2006
Reference
Hours
\
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
86
PM
80
80
78
78
78
78
78
78
78
78
78
78'
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WO)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
4/11/2018 12:24 PM • EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
2617 - AIR BARRIER AND INSULATION INSPECTION COMPONENTCRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SEDONA DEVELOPMENT 3170-3180 Builder Name:
Street: 3170-3180 MORNINGDEW LANE Permit Office: ST. LUCIE COUNTY
- City, State, Zip::. FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: ' FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
insulation and any gaps in the air barrier shall be sealed.
The insulation in any dropped ceiling/soffitthe
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
Knee walls shall be sealed.
a material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows; skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists'
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
(including
The air barrier shall be installed at any exposed edge of
insulation.
Floor framing cavity insulation shall be installed to
above -garage
maintain permanent contact with the underside of
and cantilevered
subfloor decking, or floor framing cavity insulation
'
floors)
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations,
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind and
Shower/tub
on exterior wall
The air barrier installed at exterior walls adjacent to showers and
tubs shall separate them from the
pinong woring
Exterior walls adjacent to showers and tubs shall
showers and tubs.
be insulated.
Electrical/phone bbx.or
'exterior
The air barrier shall be installed behind electrical or communication
walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed! When required to be sealed, concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I between
fire spreink a. In addition, inspection of log walls shall be inwalls or wilonrin
accoCoverrdance with the provisions of ICC-400.
4/11/2018 1'2.2d PM C-..-_..__..___ .
Uy%7"Hw v uQt%- riarceszUl i HA; 6th Edition (2017) Compliant Software Page 1 of 1
. . I
FORM R405-2017 .
P.NERGY PERFORMANCE 'LEVEL (EPL)
DISPLAY CAR
ESTIMATED ENERGY PERFORMANq.E INDEX* = 95
The lower the EnergyPerformance Index, the more ,efficient the home.
3170-3180 MORNINGDEW LANE, FT. PIERCE, FL,
1. New construotion 'or existing
2. Single family or multiple family
3. Number ofunits, if multiple family
4. Numberof Bi edrooms
S. Is this a worst case?
Ei. Conditioned floor:area (W)
7. Windows"' Description
a. U-Factor: Dbl, U=0.65
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.60
SHGC: SHGC=0.25
c. U-Factor. NIA
SHGC:
d. U-Factor. N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. WA
New (From Plans)
9. Wall Types ,
Insulation Area
Multi -family
a. Concrete Block - Int Insul, Exterior
R=4.1 6420.00 ft2
6
b. N/A
R= ft2
.
c. N/A
R= ft2
12
d. N/A
R= ft2
No
10. Ceiling Types;:
Insulation Area
a. Under Attic (Vented)
R=30.0 4046.00 ft2
4044
b. N/A
R= ft2
Area
c. N/A
R= ft2
ft2
11. Ducts
3 additional duct system(s)
R ft2240.00
6 135
b. Sup: Attic, het: Attic, AH: UNIT 1
6 135
150.00 fie
c. Sup: Attic, Rek Attic, AH: UNIT 1
(see detail
12. Cooling systems
kBtu/hr Efficiency
ft2
a. Central Unit'i
18.8 SEER:16.00
b. Central Unit !
18.8 SEER:16.00
ft2
3 additional cooling systems
(see details)
13. Heating systems
kBtu/hr Efficiency
1.000 ft.
a. Electric Strip; Heat
17.0 COP:1.00
0.250
b. Electric Stripj Heat
17.0 COP:1.00
3 additional heating systems
(see details)
Insulation
Area
14. Hot water systems
R=0.0
4044.00 W
a. Electric
Cap: 40 gallons
R=
ft2
EF: 0.95
R=
ft2
b. Conservation features
None
16. Credits
CF, Pstat
I 'certify that this home has c plied with the Florida Energy Efficiency Code for B;uildir
Construction through t b e energy saving features which will be installed (or excel
in this home°before fi I ction. Otherwise, a new EPL Display Card ill be ompli
based on installed C de c pliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energypauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
- **Label.required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I
4/11 /201812.14 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
a '
rrd s+r� Right -Suite® Universal 2017 Short Form
AHU #6
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
For: SEDONA DEVELOPMENT
3170-3180 MORNINGDEW LANE, FT. PIERCE, FL
Job:
Date: FEBRUARY 16, 2018
By:
Htg Clg
Htg Clg
Outside db
(°F) 42 90
Inside db
(°F) 70 75
Outside RH
(%) - 60
Inside RH
(%) - 50
Outside wb
(°F) - 78
Inside wb
(°F) - 63
Daily range
(°F) - 15
Design TD
(°F) 28 15
Moisture dill.
(gr/lb) - 61
Heating Equipment
Cooling Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
143.2 °F
212 cfm
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static Pressure Across Fan
Make
Trane
Model
4TTR6018J/TEM4AOB 18
Type
Split AC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
Leaving Air Temp
55.0
°F
Actual Cooling Fan
627
cfm
AHU #6
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
I Area
ftz
I Heat
Loss
I Sensible
Gain
I Latent
Gain
I Htg
cfm
Clg
i cfm
I Time
BED #1
188
5262
6226
628
79
285
Jul 1700 LDT
BTH #1
40
713
396
134
10
17
Jul 1700 LDT
KIT/LIV.
274
3531
2284
916
48
97
Jul 1700 LDT
ENTRY 1
69
2216
854
591
29
36
Jul 1700 LDT
BED #2.
111
2934
4266
278
45
192
Jul 1700 LDT
AHU #6
682
14656 1
14027 1
2547
1 212
627
Jul 1700 LDT
wrightSOft' Right -Suite® 2018-Feb-16 10:40:28 Universal 2017 17.0.14 RSU08101 Page 1
VACISEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Cale = CLTD Front Door faces: N
Htg Clg
Outside db
(°F)
42 90
Outside RH
N
- 60
Outside wb
(°F)
- 78
Daily range
(°F)
- 15
Moisture dill.
(gr/lb)
- 61
Heating Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
137.2 °F
231 cfm
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static Pressure Across Fan
Htg Cig
Inside db
(°F)
70 75
Inside RH
N
- 50
Inside wb
(°F)
- 63
Design TD
(°F)
28 15
Cooling Equipment
Make
Trane
Model
4TTR6018J/TEM4AOB 18S
Type
Split AC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
Leaving Air Temp
55.0
°F
Actual Cooling Fan
627
cfm
UNIT #1
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
I Area
ft2
I Heat
Loss
I Sensible
Gain
I Latent
Gain
I Htg
cfm
I Clg
cfm
I Time
BEDROOM 1
188
5270
6401
818
87
282
Jul 1700 LDT
BATH
40
714
267
0
11
11
Jul 1700 LDT
KITCHEN LIVING
278
3390
2929
0
50
116
Jul 1700 LDT
BEDROOM 2
107
3059
4744
817
51
196
Jul 1700 LDT
ENTRY
69
2219
565
0
32
23
Jul 1700 LDT
UNIT #1
682
14652
14906
1635
1 231
627
1 Jul 1700 LDT
I" ' rightsoftl Right-SuiteO Universal2017 17.0.14 RSU08101
VAC\SEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
2018-Feb-16 10:40:28
Page 2
-- wigph softy Right-S uite® Universal 2017 Short Form
UNI T #2
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Date:
By:
FEBRUARY 16, 2018
For: SEDONA DEVELOPMENT
_
3170-3180 MORNINGDEW LANE, FT. PIERCE, FL
Htg Clg
Htg
Clg
Outside db (°F)
42 90
Inside db (°F) 70
75
Outside RH (%)
- 60
Inside RH (%) -
50
Outside wb (°F)
- 78
Inside wb (°F) -
63
Daily range (°F)
- 15
Design TD (°F) 28
15
Moisture dill. (gr/lb)
- 61
Heating Equipment
Cooling Equipment
Make
Make
Trane
Model
Model 4TTR6018J/TEM4AOB18
Type
Elec strip
Type
Split AC
Efficiency
100 EFF
COP / EER / SEER
16.0
Heating Input
5.0 kW
Sensible Cooling
13.2
MBtuh
• Heating Output
17.1 MBtuh
Latent Cooling
5.6
MBtuh
Humidifier
2.5 gpd
Total Cooling
18.8
MBtuh
_ Leaving Air Temp
173.5 °F
Leaving Air Temp
55.0
°F
Actual Heating Fan
150 cfm
Actual Cooling Fan
627
cfm
Equipment Location
UNIT #2
"
System Type
PEAKCV
Fan Motor Heat Type
PACKAGE
Fan & Motor Combined Efficiency
0 %
Static Pressure Across Fan
0 in H2O
NAME
I Area
ftz
I Heat
Loss
I Sensible
Gain
I Latent
Gain
I Htg
cfm
I Cig
cfm
I Time
BEDROOM #1
188
4785
6383
818
62
318
Jul 1700 LDT
KITCHEN/LIVING.
274
2160
1403
916
23
63
Jul 1700 LDT
BATH #1
40
315
190
134
3
9
Jul 1700 LDT
BEDROOM #2
111
2665
4563
468
35
205
Jul 1700 LDT
ENTRY,
54
2268
796
553
26
33
Jul 1700 LDT
UNIT #2
667
12193
13336
2889 1
150
627
1 Jul 1700 LDT
wri htSoft^ 2018-Feb-1610:40:28
" Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3
...VAC\SEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
Htg Clg
Htg Clg
Outside db
(OF)
42 90
Inside db (OF)
70 75
Outside RH
N
- 60
Inside RH N
- 50
Outside wb
(OF)
- 78
Inside wb (OF)
- 63
Daily range
(OF)
- 15
Design TD (OF)
28 15
Moisture dill.
(gr/lb)
- 61
Heating Equipment
Cooling Equipment
Make
Make
Trane
Model
Model
4TTR6018J/TEM4AOB18
Type
Elec strip
Type
Split AC
Efficiency
100 EFF
COP / EER / SEER
16.0
Heating Input
5.0 kW
Sensible Cooling
13.2
MBtuh
Heating Output
17.1 MBtuh
Latent Cooling
5.6
MBtuh
Humidifier
2.5 gpd
Total Cooling
18.8
MBtuh
Leaving Air Temp
173.5 OF
Leaving Air Temp
55.0
OF
. Actual Heating Fan
150 cfm
Actual Cooling Fan
627
cfm
Equipment Location
UNIT #3
System Type
PEAKCV
Fan Motor Heat Type
PACKAGE
-
Fan & Motor Combined Efficiency
0
%
Static Pressure Across Fan
0
in H2O
NAME
I Area
ftz
I Heat
Loss
I Sensible
Gain
I Latent
Gain
I Htg
cfm
I Clg
cfm
I Time
BEDROOM 1.
188
4720
6349
818
62
316
Jul 1700 LDT
BATH 1
40
312
189
134
3
9
Jul 1700 LDT
KITHCEN/LIVING.
278
2167
1415
929
24
63
Jul 1700 LDT
BEDROOM 2.
107
2607
4568
458
34
205
Jul 1700 LDT
ENT.
54
2240
801
553
26
34
Jul 1700 LDT
UNIT #3
667
12046
13321
2892
150
627
1 Jul 1700 LDT
ri htSOftg 2018-Feb-1610:40:28
Right-SuiteC�Universal 201717.0.14RSU08101 Page
... VAC\SEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
wri h o .
Right -Suite@ Universal 2017 Shari Form Date: FEBRUARY 16, zo,3
UNIT #4 By:
QUICK CALCS, INC.
•
For: D• DEVELOPMENT
1 :1 MORNINGDEW
Htg Clg
Htg Clg
Outside db
(°F) 42 90
Inside db
(°F) 70 75
Outside RH
(%) - 60
Inside RH
(%) - 50
Outside wb
(°F) - 78
Inside wb
(°F) - 63
Daily range
(°F) - 15
Design TD
(°F) 28 15
Moisture diff.
(gr/lb) - 61
Heating Equipment
Cooling Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
Leaving Air Temp
Actual Heating Fan
Elec strip
100 EFF
5.0 kW
17.1 MBtuh
2.5 gpd
173.5 °F
150 cfm
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static Pressure Across Fan
Make
Trane
Model
4TTR6018J/TEM4AOB18
Type
Split AC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
Leaving Air Temp
55.0
°F
Actual Cooling Fan
627
cfm
UNIT #4
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
I Area
ft2
I Heat
Loss
I Sensible
Gain
I Latent
Gain
I Htg
cfm
I Clg
cfm
I Time
BEDROOM #1.
188
4275
5712
818
62
293
Jul 1700 LDT
KIT./ LIV
274
1968
2390
916
23
107
Jul 1700 LDT
BATH #1.
40
287
170
134
3
8
Jul 1700 LDT
ENTRY..
54
2053
713
553
26
31
Jul 1700 LDT
BED. 2
ill
2380
4083
468
35
189
Jul 1700 LDT
UNIT #4
667
10963
13068
2889
1 150
627
1 Jul 1700 LDT
2018-Feb-16 10:40:28
wrighftSOft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5
...VACISEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
Htg Clg
Htg Cig
Outside db
(°F) 42 90
Inside db
(°F) 70 75
Outside RH
N - 60
Inside RH
N - 50
Outside wb
(°F) - 78
Inside wb
(°F) - 63
Daily range
(°F) - 15
Design TD
(°F) 28 15
Moisture diff.
(gr/lb) - 61
Heating Equipment
Cooling Equipment
Make
Model
Type
Elec strip
Efficiency
100 EFF
Heating Input
5.0 kW
Heating Output
17.1 MBtuh
Humidifier
2.5 gpd
_ Leaving Air Temp
94.8 °F
Actual Heating Fan
627 cfm
_
Equipment Location
-
System Type
Fan Motor Heat Type
-
Fan & Motor Combined Efficiency
Static Pressure Across Fan
Make
Trane
Model
4TTR6018J/TEM4AOB 18
Type
Split AC
COP / EER / SEER
16.0
Sensible Cooling
13.2
MBtuh
Latent Cooling
5.6
MBtuh
Total Cooling
18.8
MBtuh
Leaving Air Temp
55.0
°F
Actual Cooling Fan
627
cfm
UNIT #5
PEAKCV
PACKAGE
0
%
0
in H2O
NAME
I Area
ft2
I Heat
Loss
I Sensible
Gain
I Latent
Gain
I Htg
cfm
I Clg
cfm
Time
KIT/LIV
278
1996
2425
929
100
108
Jul 1700 LDT
BED. 1
188
4275
5712
818
259
291
Jul 1700 LDT
BTH 1
40
287
170
134
14
8
Jul 1700 LDT
BED. #2
107
2360
4109
458
144
189
Jul 1700 LDT
ENT..
54
2053
721
553
109
31
Jul 1700 LDT
UNIT #5
667
10972 1
13137
1 2892
1 627
627
1 Jul 1700 LDT
1 ri htSOf ' 2018-Feb-1610:40:28
Right-Suite®Universal 201717.0.14RSU08101 Page
VACISEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc= CLTD Front Door faces: N
- Right -Suite® Universal 2017 Load Summary
- vmr 1ght oft6
Job:
Date:
FEBRUARY 16, 2018
-
AHU #6
By:
QUICK CALCS, INC.
- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM
For: SEDONA DEVELOPMENT
3170-3180 MORNINGDEW LANE, FT. PIERCE, FL
Zone: . AH
7,_p COOLING:'LOADry
I.
DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT
Inside: 75 °F Outside: 90 °F TD:
15 °F
RH: 60 % MoistDiff. 61.5 gr/lb Mult:
1.0 Ins.wb
63 °F
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
4121
-
3.
TRANSMISSION GAINS Sensible
4954
-
Walls: 2262
-
-
Glass: 1285
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1306
4.
INTERNAL HEAT GAIN Sensible Latent
0
0
Occupants: 0 0
-
-
Lights: 0 -
-
-
Motors: 0 -
-
-
Appliances: 0 0
-
5.
INFILTRATION: Outside air cfm: 61
975
2547
- 6.
SUBTOTAL: Space load Sensible Latent
10049
2547
Envelope 10049 2547
-
-
Less external 0 -
-
-
Redistribution 0 0
-
-
7.
SUPPLY DUCT
2364
-
8.
SUBTOTAL: Space load + supply duct
12413
-
Actual cfm: 627 at supply TD: 20
9.
VENTILATION: Make-up air cfm: 0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (net)
0
-
11.
RETURN DUCT
1614
-
12.
TOTAL LOADS ON EQUIPMENT
14027
2547
13. DESIGN CONDITIONS
Inside: 70 °F
Outside: 42 °F
14.
TRANSMISSION LOSSES
Walls:
3470
Glass:
2481
Doors:
194
Partitions:
0
Floors:
1378
Ceilings:
511
15.
INFILTRATION:
Outside air cfm:
16.
SUBTOTAL: Space load
Envelope
11002
Less external
0
Less transfer
0
Redistribution
0
17.
SUPPLY DUCT:
18.
VENTILATION:
Make-up air cfm:
19.
HUMIDIFICATION
Piping
" 20.
RETURN DUCT
21.
TOTAL HEATING LOAD
ON EQUIPMENT
Mult: 1.0
TD: 28 °F
99
8035
2968
11002
2134
0
950
0
570
14656
wri ht-SO t' 2018-Feb-1610:40:28
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
VACISEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
- i pF� oft Right -Suite® Universal 2017 Load Summary
UNIT #1
Job:
Date: FEBRUARY 16, 2018
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772A66-6796 Email: QUICKCALCS@AOL.COM
For: SEDONA DEVELOPMENT
3170-3180 MORNINGDEW LANE, FT. PIERCE,
FL
one' - 3 U,NIt #1 _ _k ,_ . CQQLING LOAD,:'s _
_• _-.".
1.
DESIGN CONDITIONS at Jul 1700 LDT
Peak load at Jul 1700 LDT
Inside: 75 °F Outside: 90 °F
TD:
15 °F
RH: 60 % MoistDiff. 61.5 gr/lb
Mult:
1.0 Ins.wb
63 °F
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
4154
-
3.
TRANSMISSION GAINS Sensible
4648
-
Walls: 1957
-
-
Glass: 1285
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1306
4.
INTERNAL HEAT GAIN Sensible
Latent
1391
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 931
0
-
-
5.
INFILTRATION: Outside air cfm:
30
480
1255
6.
SUBTOTAL: Space load Sensible
Latent
10673
1635
Envelope 10673
1635
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
7.
SUPPLY DUCT
2515
-
S.
SUBTOTAL: Space load + supply duct
13189
-
Actual cfm: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up air cfm:
0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (net)
0
-
11.
RETURN DUCT
1717
-
12.
TOTAL LOADS ON EQUIPMENT
14906
1635
v
13.
DESIGN CONDITIONS
Mult:
1.0
Inside: 70 °F Outside: 42 °F ,
TD:
28 °F
14.
TRANSMISSION LOSSES
8008
-
Walls: 3444
-
Glass: 2481
-
Doors: 194
-
Partitions: 0
-
Floors: 1378
-
Ceilings: 511
-
15.
INFILTRATION: Outside air cfm:
97
2971
16.
SUBTOTAL: Space load
10980
Envelope 10980
-
Less external 0
-
Less transfer 0
-
Redistribution 0
-
- 17.
SUPPLY DUCT:
2145
18.
VENTILATION: Make-up air cfm:
0
0
19.
HUMIDIFICATION
954
Piping
0
20.
RETURN DUCT
574
21.
TOTAL HEATING LOAD ON EQUIPMENT
14652
2018-Feb-1610:40:28
ivVt'1 htSOftt Right-Suite®Universal 2017 17.0.14 RSU08101
Page 2
VACISEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
.COOLINGLOAD..'.
1.
DESIGN CONDITIONS at Jul 1700 LDT
Peak load at Jul 1700 LDT
Inside: 75 °F Outside: 90 °F
TD:
15 °F
RH: 60 % MoistDiff: 61.5 gr/lb
Mult:
1.0 Ins.wb
63 °F
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3513
-
Walls: 1016
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
-
-
4.
INTERNAL HEAT GAIN Sensible
Latent
527
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 67
0
-
-
5.
INFILTRATION: Outside air cfm:
60
960
2509
- 6.
SUBTOTAL: Space load Sensible
Latent
8954
2889
Envelope 8954
2889
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
7.
SUPPLY DUCT
2605
-
8.
SUBTOTAL: Space load + supply duct
11560
-
Actual cfm: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up air cfm:
0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (net)
0
-
11.
RETURN DUCT
1776
-
12.
TOTAL LOADS ON EQUIPMENT
13336
2889
13.
DESIGN CONDITIONS
Mult:
1.0
Inside: 70 °F Outside: 42 °F
TD:
28 °F
14.
TRANSMISSION LOSSES
4852
Walls: 1357
-
Glass: 2162
-
Doors: 194
-
Partitions: 0
-
Floors: 638
-
Ceilings: 500
-
15.
INFILTRATION: Outside air cfm:
95
2926
16.
SUBTOTAL: Space load
7778
Envelope 7778
-
Less external 0
-
Less transfer 0
-
Redistribution 0
-
17.
SUPPLY DUCT:
2751
18.
VENTILATION: Make-up air cfm:
0
0
19.
HUMIDIFICATION
933
Piping
0
20.
RETURN DUCT
731
21.
TOTAL HEATING LOAD ON EQUIPMENT
12193
�� 2018-Feb-16 10:40:28
Right -Suite® Universal 2017 17.0.14 RSU08101 Page
VAMSEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
Right -Suite® Universal 2017 Load Summary
. wEightsG' ° UNIT #3
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Job:
Date:
FEBRUARY 16, 2018
For: SEDONA DEVELOPMENT
3170-3180 MORNINGDEW LANE, FT. PIERCE,
FL
:. COO:LING: L'OAD.. U.NIT..#3 .. .. _ . ._..:�. �. ...
-
1.
DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT
Inside: 75 °F Outside: 90 °F TD:
15 °F
RH: 60 % MoistDiff: 61.5 gr/lb Mult:
1.0 Ins.wb
63 °F
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3551
-
Walls: 1053
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
-
-
4.
INTERNAL HEAT GAIN Sensible Latent
527
380
Occupants: 460 380
-
-
Lights: 0 -
-
-
Motors: 0 -
-
-
Appliances: 67 0
-
-
5.
INFILTRATION: Outside air cfm: 60
962
2512
6.
SUBTOTAL: Space load Sensible Latent
8993
2892
Envelope 8993 2892
-
-
Less external 0 -
-
-
Redistribution 0 0
-
-
7.
SUPPLY DUCT
2574
-
8.
SUBTOTAL: Space load + supply duct
11567
-
Actual cfm: 627 at supply TD: 20
-
-
_ 9.
VENTILATION: Make-up air cfm: 0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (net)
0
-
11.
RETURN DUCT
1755
-
12.
TOTAL LOADS ON EQUIPMENT
13321
2892
nx x
HEATING'LO�iP.__
13.
DESIGN CONDITIONS Mult:
1.0
Inside: 70 °F Outside: 42 °F TD:
28 °F
14.
TRANSMISSION LOSSES
4852
Walls: 1357
-
Glass: 2162
-
Doors: 194
-
Partitions: 0
-
Floors: 638
-
Ceilings: 500
-
15.
INFILTRATION: Outside air cfm: 95
2930
16.
SUBTOTAL: Space load
7782
Envelope 7782
-
Less external 0
-
Less transfer 0
-
Redistribution 0
-
17.
SUPPLY DUCT:
2629
18.
VENTILATION: Make-up air cfm: 0
0
19.
HUMIDIFICATION
937
Piping
0
20.
RETURN DUCT
698
21.
TOTAL HEATING LOAD ON EQUIPMENT
12046
.}
' 1 h Oft'
2018-Feb-16 10:40:28
f
Right -Suite® Universal 2017 17.0.14 RSU08101
Page 4
VAC\SEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
w ,Zontti. t7Nl #4 , ° ... _ ,�. C.00'CiING TOAD_
1.
DESIGN CONDITIONS at Jul 1700 LDT
Peak load at Jul 1700 LDT
Inside: 75 OF Outside: 90 OF
TD:
15 OF
RK 60 % MoistDiff: 61.5 gr/lb
Mult:
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3513
-
Walls: 1016
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
-
-
4.
INTERNAL HEAT GAIN Sensible
Latent
1378
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
-
Appliances: 918
0
-
-
5.
INFILTRATION: Outside air cfm:
60
960
2509
6.
SUBTOTAL: Space load Sensible
Latent
9805
2889
Envelope 9805
2889
-
-
Less external 0
-
-
-
Redistribution 0
0
-
-
- 7.
SUPPLY DUCT
1947
-
8.
SUBTOTAL: Space load + supply duct
11752
-
_
Actual cfm: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up air cfm:
0
0
0
10.
RETURN AIR LOAD: Lighting + plenum (net)
0
-
11.
RETURN DUCT
1316
-
12.
TOTAL LOADS ON EQUIPMENT
13068
2889
13.
DESIGN CONDITIONS
Mult:
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF
14.
TRANSMISSION LOSSES
4852
Walls: 1357
-
Glass: 2162
-
Doors: 194
-
Partitions: 0
-
Floors: 638
-
Ceilings: 500
-
15.
INFILTRATION: Outside air cfm:
95
2926
16.
SUBTOTAL: Space load
7778
Envelope 7778
-
Less external 0
-
Less transfer 0
-
Redistribution 0
-
17.
SUPPLY DUCT:
1786
18.
VENTILATION: Make-up air cfm:
0
0
19.
HUMIDIFICATION
933
Piping
0
20.
RETURN DUCT
466
21.
TOTAL HEATING LOAD ON EQUIPMENT
10963
' toillght ift
2018-Feb-1610:40:28
Right-Suite® Universal 2017 17.0.14 RSU08101
Page 5
VAMSEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
�� 0 Right -Suite® Universal 2017 Load Summary Job:
UNIT �#5 DDate: FEBRUARY 16, 2018
QUICK CALCS, INC.
Zone; NI.T G.L
-#5_ _ .._..a __ CO.OLINOAD
1.
DESIGN CONDITIONS at Jul 1700 LDT
Peak load
at Jul 1700 LDT
Inside: 75 °F Outside: 90 °F
TD:
15 °F
RH: 60 % MoistDiff: 61.5 gr/lb
Mult:
1.0 Ins.wb
63 °F
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
3954
-
3.
TRANSMISSION GAINS Sensible
3551
-
Walls: 1053
-
-
Glass: 1120
-
-
Doors: 101
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings: 1277
4.
INTERNAL HEAT GAIN Sensible
Latent
1391
380
Occupants: 460
380
-
-
Lights: 0
-
-
-
Motors: 0
-
-
-
Appliances: 931
0
-
-
5.
INFILTRATION: Outside air cfm:
60
962
2512
• 6.
SUBTOTAL: Space load Sensible
Latent
9857
2892
Envelope 9857
2892
-
-
Less external 0
-
-
-
_
Redistribution 0
0
-
-
• 7.
SUPPLY DUCT
1957
-
8.
SUBTOTAL: Space load + supply duct
11814
-
.
Actual cfm: 627 at supply TD:
20
-
-
9.
VENTILATION: Make-up air cfm:
0
0
0
10
RETURN AIR LOAD L' ht' + I t
0
-
Ig Ing p enum (ne )
11. RETURN DUCT 1323 -
12. TOTAL LOADS ON EQUIPMENT 13137 2892
HEATING, LOAD
13.
DESIGN CONDITIONS
Inside: 70 °F Outside:
42 °F
14.
TRANSMISSION LOSSES
-
Walls:
1357
Glass:
2162
Doors:
194
Partitions:
0
-
Floors:
638
Ceilings:
500
15.
INFILTRATION: Outside air cfm:
16.
SUBTOTAL: Space load
Envelope
7782
Less external
0
Less transfer
0
Redistribution
0
17.
SUPPLY DUCT:
18.
VENTILATION: Make-up air cfm:
19.
HUMIDIFICATION
Piping
" 20.
RETURN DUCT
21.
TOTAL HEATING LOAD ON EQUIPMENT
Mult: 1.0
TD: 28 °F
95
Al
4852
2930
7782
1787
0
937
0
466
10972
wri htsoft, 2018-Feb-1610:40:28
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6
VAMSEDONA DEVELOPMENT-3170-3180 MORNINGDEW.rup Calc = CLTD Front Door faces: N
Im
'00
R
----------- -----
C)
...............
...... ......
.
OU
>
...................................................
. ................. ..........
; .......................
............... . ...........................
I
Ob
2-4-1
45-4-
21
Mean Dld'o. Ht. 14' 0'":
Townhouse 5U11,41MO John M. Foster - Architect
Jd St. Lucie Country. FI&HA.
. . . ......... . .. ......