HomeMy WebLinkAboutSTRUCTURAL DESIGN MANUAL ALTERNATE' NL;A 1 WW SU00',fi" merican Buildings Company 7 8.1.11 Standing Seam 360 Panel Properties and Section Properties PANEL PROFILE 24" 2 29132� 2• I � 3' 491W 51/16' 51116' 49116' /4' 2 3/8' is 1/4' 2 51e• CROSS SECTION Engineering Properties of American Buildings Company Standing Seam 360 Panel (ASD) Designated Steel Base Total Panel Base Top In Bottom In Gage Yield Metal Thick. Metal Weight Compression Compression Fb Of KSI Thick. (In.) (lbs. / ft.z) KSI Ix Sx Me & Sx Me Steel (In.) (In.4 / ft.) (In.3 / ft.) K4N. / ft. (In.4./ ft.) (In.3 / ft.) K4N. / ft. 24 Ga. 50 0.0225 0.0241 1.13 0.278 0.116 3.48 0.126 0.080 2.41 30 22 Ga. 50 0.0300 0.0316 1.50 0.372 0.159 4.76 0.177 0.111 3.32 30 Gage Of Panel No. of Spans Load Type Mabmum Total Uniform Load in PSF Span Lengths, Ft. 1.50 2. 1 250 3.00 3,50 4.00 4.50 5.00 1 POS 1032 B 5811 B 1 372 B 258 B 190 B 145 B 115 B 93 B 24 Ga. 2 POS 548 B+s 340 B+5 230 B+s 165 B+s 123 B+s 96 B+S 76 B+s 62 B+s 3 POS 631 B+s 402 B+s 275 B+s 199 B+S 151 B+5 117 B+S 94 B+s 71 a+5 4 POS 606 B+s 382 B+s 261 B+s 188 B+S 142 B+S 110 B+S B8 B+s 7 0 B+s 1 POS 1409 B 793 B 507 B 352 B 259 B 198 B 157 B 127 B 22 Ga. 2 POS 798 B+s 487 B+s 325 B+s 231 B+s 173 B+5 133 B+s 106 B+s 86 B+s 3 POS 930 B+5 580 B+s 393 s+s 282 BLS212 B+S 164 B+s 131 B+s 107 B+s 4 POS 889 a+S 551 B+s 371 s+s 266 B+s 199 B+S 1 154 B+s 123 a+s 100 B+s 1. The panels are checked for bending (B), shear (S), combined bending and shear (B+S) and deflection (D). The controlling check is noted in the table. Deflection is limited to span/60. 2. Section Properties are calculated in accordance with the 2012 North American Specification for the Design of Cold -Formed Steel Structural &bmbe/s. 3. Minimum yield strength of 24 and 22 gage steel is 50.000 psi. 4. Steel panels are either aluminum -zinc alloy or G-90 coaled. The base metal thickness is used in determining section properties. 5. Positive load (POS) is applied inward toward the panel supports, and is applied to the outer surface of the full panel cross-section. Revised 08-28-2015 (EB.04.2015) Section 8.1.11 Page 1 American Buildings Company Index• Tables la, lb, lc & ld: DESIGN UPLIFT for wind speeds <_ 110 mph (IBC and Legacy Codes older than 2006). The values in these tables are the maximum allowable loads from either UL 580 or E 1592 tests. The values from E 1592 tests include a Dynamic Conversion Factor. Unless noted otherwise, the values were checked for screw pullout in 16 gauge (0.060") material using two screws per panel clip. . Tables 2a, 2b, 2c & 2d: DESIGN UPLIFT for wind speeds > 110 mph (IBC and Legacy Codes older than 2006). The values in this table are the maximum allowable loads from either UL 580 or E 1592 tests. Unless noted otherwise, the values were checked for screw pullout in 16 gauge (0.060") material using two screws per panel clip. Example 1 Tables 3a, 3b & 3c: DESIGN UPLIFT for Standing Seam lI for all wind speeds (2006 and newer versions of IBC). Some tables include a 50% increase in the allowable uplift values in the corner and perimeter zones. The values in these tables are the maximum allowable loads fiom E 1592 tests. Unless noted otherwise, the values were checked for screw pullout•in 16 gauge (0.060") material using two screws per panel clip. Tables 4a thru 4e: DESIGN UPLIFT for Standing Seam 360 for all wind speeds (2006 and newer versions of 113C). Some tables include a 50% increase in the allowable uplift values in the corner and perimeter zones. The values in these tables are the maximum allowable loads from E 1592 tests. Unless noted otherwise, the values were checked for screw pullout in 16 gauge (0.060") material using two screws per panel clip. Tables 5a & 5b: DESIGN UPLIFT for Loc Seam for all wind speeds (2006 and newer versions of IBC). Some tables include a 50% increase in the allowable uplift values in the corner and perimeter zones. The values in these tables are the maximum allowable loads from E 1592 tests. Unless noted otherwise, the values were checked for screw pullout in 16 gauge (0.060") material using two screws per panel clip. Tables 6a & 6b: DESIGN UPLIFT for Loc Seam 360 for all wind speeds (2006 and newer versions of IBC). Some tables include a 50% increase in the allowable uplift values in the corner and perimeter zones. The values in these tables are the maximum allowable loads from E 1592 tests. Unless noted otherwise, the values were checked for screw pullout in 16 gauge (0.060") material using two screws per panel clip. Table 7a: DESIGN UPLIFT for Seam Loc for all wind speeds (2006 and newer versions of 1BC). The values in these tables are the maximum allowable loads from E 1592 tests. Unless noted otherwise, the values were checked for screw pullout in 16 gauge (0.060") material using two screws per panel clip. Example 2 IBC Version NASPEC Version Adopted by IBC 2000 1996 2003 2001 2006 2001 with 2004 Supplement 2009 2007 2012 2007 with 2010 Supplement Revised 5-14-2012 (EB.08.2012) Section 8.2, Page 2 American Buildings Company • Joo �oaJu. Table 4e: Applicable to roofs designed to the 2009 and newer versions of IBC. 24 GA. STANDING SEAM 360 See Table 4e for.uptift values with Reinforced Clips and Seam Clamps DESIGN UPLIFT (PSI) Applicable to roofs designed to the 2009 and newer versions of IBC* Purlin Spacing Ft. Mid -Field Edge Strip & Corner Zones* Purlin Thicknesses Purlin Thicknesses 16 Ga. > 15 Ga. 16 Ga. > 15 Ga. 1.00 149.1 149.1 149.1 149.1 1.50 129.9 129.9 136.4 136.4 2.00 110.6 110.6 136.4 136.4 2.50 91.4 91.4 136.4 136.4 3.00 83.0 83.0 123.8 123.8 3.50 73.4 74.5 109.6 111.3 4.00 64.3 66.1 95.9 98.7 4.50 57.1 57.7 85.2 86.1 5.00 49.3 49.3 73.5 73.5 5.27 44.7 44.7 66.7 66.7 *These tables include a 50% increase in the allowable uplift values in the corner and perimeter zones as allowed for by the 2012 NASPEC Section D6.2.1a with the added stipulation that the purlin spacing in the corner and perimeter zones cannot be greater than the purlin spacing in the mid -field of the roof. This increase is applicable to purlin spacings between 5.27' and 2.5'. The values for spacings less than 2.5' use the higher of the E1592 results without the increase and the value at 2.5'. The increase is only allowed when anchor failure is the controlling failure mode. Therefore, no increase is included for spans less than 2.5' because failure occurred in these tests away from the anchors. This increase is not allowed in Canada. Table 4d: Applicable to roofs designed to the 2009 and newer versions of IBC. 22 GA. STANDING SEAM 360 See Table 4e for uplift values with Reinforced Clip and Seam Clamps DESIGN UPLIFT (PSF) Applicable to roofs designed to the 2009 and newer versions of IBC* Purlin Spacing Ft. Mid -Field Edge Strip & Corner Zones* Purlin Thicknesses Purlin Thicknesses 16 Ga. 15 Ga. 14 Ga. > 13 Ga. 16 Ga. 15 Ga. 14 Ga. >_ 13 Ga. 1.00 148.8 148.8 148.8 148.8 190.3 190.3 190.3 190.3 1.50 141.7 141.7 141.7 141.7 171.3 190.3 190.3 190.3 2.00 128.5 134.6 134.6 134.6 153.4 171.3 190.3 190.3 2.50 102.8 114.8 127.5 127.5 153.4 171.3 190.3 190.3 3.00 85.7 95.7 107.0 114.7 127.9 142.8 159.7 171.1 3.50 73.4 82.0 91.7 101.8 109.6 122.4 136.9 151.9 4.00 64.3 71.8 80.3 89.0 95.9 107.1 119.8 132.8 4.50 57.1 63.8 71.3 76.1 85.2 95.2 106.5 113.6 5.00 51.4 57.4 63.3 63.3 76.7 85.7 94.4 94.4 5.27 48.8 1 54.5 56.3 56.3 72.8 81.3 84.0 84.0 Notes: a) All values are from ASTM E 1592 tests with a check of the clip-to-purlin connection using 2 screws unless noted otherwise, and a minimum 16 gauge (0.060") purlin. b) Interpolation between spans is acceptable, but extrapolation for spans less than P-0" and greater than 5'-3'/" is not allowed. Revised 08-28-2015 (EB.04.2015) Section 8.2, Pagel 1 M ye 0 American Buildings Company Table 4e: Applicable to roofs designed to the 2009 and newer versions of IBC. DESIGN UPLIFT (PSF) Applicable to roofs designed to the 2009 and newer versions of IBC* Purlin Spacing t, Reinforced Clips SSH: SSPC_ with SSCH SS360: S3PC- R Seam Clamps, RSC '. Mid -Field Edge Strip & Corner Zones* Mid- Field Edge Strip & Corner Zones* . Purlin Thicknesses Purlin Thicknesses Purlin Thicknesses, 16 Ga. 15 Ga. >_ 14 Ga. 16 Ga. 15 Ga. > 14 Ga. > 16 Ga, 1.00 101.0 101.0 101.0 150.7 150.7 150.7 119.3 178.1 1.50 101.0 101.0 101.0 150.7 150.7 150.7 109.3 163.2 2.00 101.0 101.0 101.0 150:7 150.7 150.7 ' 99.4 148.3. 2.50 101.0 101.0 101.0 150.7 150.7 150.7 .89.4 133.4 3.00 85.7 92.6 92.6 127.9 138.1 138.1 79.6 118.9 3.50 73.4 82.0 84.1 109.6 122.4 125.5 69.9 104:3 4.00 64.3 71.8 75.7 95.9 107.1 112.9 60.1 89.7 4.50 57.1 63.8 67.2 85.2 95.2 100.3 50.3. , 75.1 5.00 51.4 57.4 58.8 76.7 85.7 1 87.7 40.6 60.5 5.27 48.8 54.2 54.2 72.8 80.9 80.9 35.3^ 52.6^ A: 45.6 psf in the mid -field and 68.1 psf in the perimeter when seam clamps are located at the roof clips and midspan between the roof clips. *This table includes a 50% increase in the allowable uplift values in the corner and perimeter zones as allowed for by the 2012 NASPEC Section D6.2.1a with the added stipulation that the purlin spacing in the corner and perimeter zones cannot be greater than the purlin spacing in the mid -field of the roof. This increase is not allowed in Canada. Notes: a) All values are from ASTM E 1592 tests with a check of the clip-to-purlin connection using 2 screws unless noted otherwise, and a minimum 16 gauge (0.060") purlin. b) Interpolation between spans is acceptable, but extrapolation for spans less than 1'-0" and greater than 5'-3Y4" is not allowed. Revised 08-28-2015 (EB.04.2015) Section 8.2, Page 12