Loading...
HomeMy WebLinkAboutPROPOSED WORKi CONTRACTOR: GULFSTREAM ALUMINUM DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 2010 Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2005 Edition 3. ASCE 7-10. Wind Loads 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Table 1609 State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: 150 MPH 3. Exposure Category, Paragraph 1609.4.3: Exposure B 4. Building Category for Aluminum Structures, Paragraph 2002.6: Building Category 1. Foundation Design Footing Size and Reinforcing: Existing concrete. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" Metals USA Composite Panel Elite 2000, 1.6 density foam, Florida Product Approval Number FL 2291-R6. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the Florida Building Code, 2010 Edition, with Supplements, and any other applicable local codes and regulations. 2. The minimum wall thickness of aluminum extrusions shall be in accordance with the Florida Building Code, 2010 Edition with Supplements and the 2005 Edition of the Aluminum Association Manual, but not less than 0.040 inches. 3. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization'of Suncoast Architecture & Engineering, LLC. 4. Fasteners are required to be SAE Grade 5 or better zinc plated. 5. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1% - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute - -- Manual-ofStandard-Practice, Parts 1 2 and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. 6. The minimum nominal thickness of protector panels (kickplates) shall be an industry standard of 0.024 inches. to 0 o_ 0 M V J I � BY s4 Luelp county f— 95" 3 X3 XO.090 POST (TYP) 88" +/— C.9 � za M: 0 Of X w o 0 ao o CO 7" BACK WALL OF EXISTING 16" ROOF OVERH 4'-O" - POLY A-2 PANELS f 3"X3"XO.090" POST I(TYP) 2X6SMB A-z THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORr,,: ;TIONS REQUIRED Ff FIELD; INSPEM>JR5 THAT MAY BE NECESSARYIN ORDF_ R TO COMPLY VVIT14 ALL APPUCASI .. CODES. �95"� POLY PANEL RECEIVER '--+1EADER TO EXISTING ROOF FASCIA 3" POLY PANEL -RECEIVER FASCIA (BOTH ENDS OF ROOF) —15' existing slab POLY PANEL RECEIVER UTTER W/ (2) 2X3 16' ROOF DOWNSPOUTS 16'-0' ROOF poly 3"X3"XO.090" POST (TYP) 3" 3" 3" 2" 15'-0" 2" EXISTING CONCRETE SLAB 3" POLY PANEL RECEIVER FASCIA (BOTH ENDS OF ROOF) 3"X3"X0.090" POST (TYP) 88" +/— ,,,,,fff *f/,/Iff,•• Q •I • - Off: . O . z •ul (0itQ O W O 2 • (� o A�A , ROES�IUNAL 1`.�� W W w _z w C7 � z Q W C7 c a a� z p u; o 2z N UJ w w ¢ LL i O F- cc W U W V U W z Q o' to LJU tomScs Q L l l V' CP O z t.; zLU 0W V) 03�d� 7" a� a] W + N 0 00 W w o Q U U o U o z A- 2)// l ���a) ST. LU&E Cab'`" fY BUILDING DWISIO\ Q N O J 2 "o a " REVIEWED FOR NEI&IAN DRAWN BY REVIEWED B11`-- TP DATE -3- ^ ?/ DATE DRAWN 0_8/07/12 AINUPERMIT MUST BEKERT_ON,JOB OR NO LNSP) &ION WILL BE ;LADE. REVISION /A - SHEET NO: A-1 ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.044" 2 x 3: 2" x 3" x 0.050" 2 x 4: 2" x 4" x 0.050" 2 x 5: 2" x 5" x 0.050" OPEN BACK SECTIONS I x 2: P x 2" x 0.040" 1 x 3: P x 2" x 0.045" SNAP SECTIONS. 2 x 2 Snap: 2" x 2" x 0.045" 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" x 4" x 0.045" SELF MATING (SM13) 2x4SMB: 2" x 4" x 0.044" x 0. 100" 2x5SMB: 2" x 5" x 0.050" x 0. 100" 2x6SNM: 2" x 6" x 0.050" x 0. 120" 2 x 7 SI%M: 2" x T'x 0.057" x 0. 120" 2x8SMB: 2" x 8" x 0.072" x 0. 124" 2x9SMB: 2" x 9" x 0.072" x 0. 124" 2 x 10 SNM: 2" x 10" x 0.092" x 0.398" (2) 318" LOT S' MI EMBE DED RECEIVING W/ (2) 318!' 1 BOLTS rBT' x 3" POST TO DECK CONNECTION DETAILS �-2 SCALE: NTS PUNS AND AI L"PROPOSED WORK ARE SUBJECT TO ANY CORT, "ITIONS REQUIRED. BY FIELD 1N,(:3PECljRS THAT. - MAYBE NECESSARY IN ORDER TO COMPLY WITH ALL AfbP "CAB'_ COD tt's a a a 9 11 is*'?, f#004 #*J. 1* m :) LL -0: C/ 0 Z w cr- Lo I.- (5) #14 X 4" SMS W/ NEOPRENE FACED WASHER EA. PANEL z dp dp NE OPRENE E WA SHER S P 9 H R A E E R E E 0' F A ,♦� % PR Ailk6iWll L cc c 3" x 48" x 0.024 LLI '0 POSIT P UJI COMPOSITE PANEL z LJ 3" RECEIVING CHANNEL (3) 3/8" DIA. (D 13- L W1#140/4"TOP AND THRU BOLTS z 1 2 BOTTOM AS END CAP If: Lu < la, LL < < ID LP 2" X 6" SMB z 0 ai LL 0 2, Q z LL Lu z uj Lu C 3" x 3" x 0.090 U. O LL POST 0 uj L Ln LL U. c z LLI if-. COMPOSITE ROOF TO POST CONNECTION Cc LL SCALE: N.T.S. c 2 b LLI u NN IL U LL < so 3 0. LL Lf) Lu t� m 0 52 0 co < Z . = z I - c 0 t;wg- z .mm u o1ptg z < FLASHING Lu tA co (2) Y4" x 1 12" LAG SCREWS 2 1" APART AT EA RAFTER c TAIL LL .040" 5032-H32 PAN TO FASCIA CONNECTOR Lu 0 LL #10 X Y4" SMS PER PAN AT :� V) TOP LLI 13- c w LU LL #10 X X4" SMS 12" C/C z a< LU LL L_j (.) Z-) z LU c PANEL DEPTH u 0 < N LLI 8F 5ML-M. CONTRACTOR TO VERIFY 0 (9 - h: ", 2"x4"MINIMUM FASCIA -IF cc < CON o _,01 Vx_ .'FASCIA OVER Z'x C. 2 co IL LL #10 X YZ SMS 12" C]C — " SUB FASCIA, LENGTHEN LAG SCREWS DRAWN BY TO FULLY PENETRATE SUB TP FASCIA. IF OTHER FASCIA, ADD 2" x 4" PT FASCIA WI DATE DRAWN -LAG BOLTS-I-Yi'INTO -08/07/12 TRUSS TAILS. WHEN INSTALLING Y? LAG SCREWS, PRE-DRILLW/ )F REVISION DRILL TO PREVENT SPLITTING. A rs__TSTANDARD ROOF PANEL CONNECTION TO FASCIA � �-2 SCALE: NTS SHEET NO: A-2