HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIE O ILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RODOLFO VEGA GUEST HOUSE Builder Name: RODOLFO VEGA Street:! 1 5704 CITRUS AVENUE SCANNED Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, N� W�� Permit Number: Owner: RODOLFO VEGA BY Jurisdiction: Design! Location: FL, Fort Pierce ��� County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1206.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1206.00 ft2 b. N/A R= ft2 3. Numb'er of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this'a worst case? No 10. Ceiling Types (961.0 sqft.) Insulation Area 11 a. Under Attic (Vented) R=30.0 961.00 ft2 6. Conditioned floor area above grade (ft2) 961 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(95.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C 6 105 a. U-Factor: Sgl, U=0.65 95.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: il a. Central Unit 22.0 SEER:14.00 C. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems l; a. Electric Cap: 50 gallons 8. Floor Types (961.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 961.00 ft2 b. Conservation features b. N/A'. R= ft2 None c. N/A' R= ft2 15. Credits CF, Pstat Glass/FI'oor Area: 0.099 Total Proposed Modified Loads: 39.83 PASS Total Baseline Loads: 40.72 l I hereby certify that the plans and specifications covered by Review of the plans and Se-tgE S7,q?, this calculation are in compliance with the Florida Energy specifications covered by this �y__ 0�, Code. calculation indicates compliance with the Florida Energy Code. mrr,., ,�•, ;f•••a ,� O PREPA ED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 r ` * �' I hereby 'certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. COD WE OWNE14%AGENT:20a01 EQ ug_sq . BUILDING OFFICIAL: DATE: !2- 25_ /Q DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/21/2019 12:13 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 5 'I .FYlRl1/I RdnF_7nl7 IMP[ IT Al IMMARY ICI4FCKLIST PFPC)RT PROJECT Title: i RODOLFO VEGA GUEST H Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 961 Lot # Owner'Name: RODOLFO VEGA Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: RODOLFO VEGA Rotate Angle: 0 Street: 5704 CITRUS AVENUE Permit I Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family;Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low I; BLOCKS Number Name Area Volume 1 Entire House 961 8649 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 2 171 1539 No 1 1 1 Yes Yes Yes 2 BATH 40 360 No 0 1 Yes Yes Yes 3 BEDROOM 190 1710 No 1 1 1 Yes Yes Yes 4 1 A/C 9 81 No 0 1 No Yes Yes 5 BATH 2 40 360 No 0 1 No Yes Yes 6 LIVING 261 2349 No 2 1 Yes Yes Yes 7 KITCHEN 100 900 No 0 1 Yes Yes Yes 8 OFFICE 100 900 No 0 1 Yes Yes Yes 9 UTILITY 50 450 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 2 27 ft 0 171 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio BATH 5 ft 0 40 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio BEDROOM 29 ft 0 190 ft2 ____ 0 1 0 4SIab-On-Grade Edge Insulatio A/C 1 ft 0 9 ft2 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 2 1 ft 0 40 ft2 ____ 0 1 0 6Slab-On-Grade Edge Insulatio LIVING 25 ft 0 261 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio I I KITCHEN loft 0 100 ft2 ____ 0 1 0 2/21/2019 12:13 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 .FORM RAn5-9nl7 INPUT SLIMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio OFFICE 20 ft 0 100 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio UTILITY 18 ft 0 50 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch �/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) i 1 Hip Metal 1013 ft2 0 ft2 Light 0.5 No 0.9 No 0 18.4 ! ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 961 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 2 30 Blown 171 ft2 0.1 Wood ! 2 Under Attic (Vented) BATH 30 Blown 40 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 30 Blown 190 ft2 0.1 Wood 4 Under Attic (Vented) A/C 30 Blown 9 ft2 0.1 Wood 5 Under Attic (Vented) BATH 2 30 Blown 40 ft2 0.1 Wood 6 Under Attic (Vented) LIVING 30 Blown 261 ft2 0.1 Wood 7 Under Attic (Vented) KITCHEN 30 Blown 100 ft2 0.1 Wood 8 Under Attic (Vented) OFFICE 30 Blown 100 ft2 0.1 Wood 9 Under Attic (Vented) UTILITY 30 Blown 50 ft2 0.1 Wood WALLS ft, Ornt Adjacent Space 10 Wall lype1 Cavity Width Height Sheathing Framing Solar Below N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 12 0 9 0 108.0 ft2 0 0 0.4 0 _ 2 S Exterior Concrete Block - Ext IndMDROOM 2 4.1 2 0 9 0 18.0 ft2 0 0 0.4 0 3 W Exterior Concrete Block - Ext IndIffDROOM 2 4.1 13 0 9 0 117.0 ft2 0 0 0.4 0 4 N Exterior Concrete Block - Ext Insul BATH 4.1 5 0 9 0 45.0 ft2 0 0 0.4 0 5 N Exterior Concrete Block - Ext Insfi]EDROOM 4.1 12 0 9 0 108.0 ft2 0 0 0.4 0 6 E Exterior Concrete Block - Ext InsfdEDROOM 4.1 15 0 9 0 135.0 ft2 0 0 0.4 0 7 S Exterior Concrete Block - Ext InsiHEDROOM 4.1 2 0 9 0 18.0 ft2 0 0 0.4 0 8 S Exterior Concrete Block - Ext Insul LIVING 4.1 5 0 9 0 45.0 ft2 0 0 0.4 0 9 W Exterior Concrete Block - Ext Insul LIVING 4.1 20 0 9 0 180.0 ft2 0 0 0.4 0 _ 10 � E Exterior Concrete Block - Ext InsuKITCHEN 4.1 10 0 9 0 90.0 ft2 0 0 0.4 0 11 i E Exterior Concrete Block - Ext InsulOFFICE 4.1 10 0 9 0 90.0 ft2 0 0 0.4 0 12 i S Exterior Concrete Block - Ext InsulOFFICE 4.1 10 0 9 0 90.0 ft2 0 0 0.4 0 13. E Exterior Concrete Block - Ext InsulUTILITY 4.1 3 0 9 0 27.0 ft2 0 0 0.4 0 141 S Exterior Concrete Block - Ext InsuIUTILITY 4.1 10 0 9 0 90.0 ft2 0 0 0.4 0 15 ! W Exterior Concrete Block - Ext InsulUTILITY 4.1 5 0 9 0 45.0 ft2 0 0 0.4 0 2/21/2019 12:13 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 .FnRnn RAnr,_gn17 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 S Insulated LIVING None .32 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 4 5 6 W 3 Metal Low-E Single N 4 Metal Low-E Single E 6 Metal Low-E Single W 9 Metal Low-E Single E 10 Metal Low-E Single E 11 Metal Low-E Single Yes Yes Yes Yes Yes Yes 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in 0.65 0.25 N 40.0 ft2 2 ft 0 in 1 ft 4 in 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1009 55.4 104.18 .3005 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14 22 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / V # -- Supply - Location R-Value Area -- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 105 ft2 Attic 40 ft2 Default Leakage A/C (Default) (Default) 1 1 2/21/2019 12:13 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R4105-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Prograrnable Thermostat: Y Ceiling Fans: Heatingl X Jan f X Feb Mar Apr f j Maay �X� Jun [ l [X] Jul Aug rj Sep �Xj Oct Nov Oct Xj Nov Dec DecVenting [ Jan [ Feb X Mar X [X] [ Jun [ ] Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 I ' PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftZ 0 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH Default(8 Ibs/sq.ft. ftZ ft 0.3 BEDROOM Default(8 Ibs/sq.ft. ftZ ft 0.3 A/C Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftZ ft 0.3 OFFICE Default(8 Ibs/s .ft. ftZ ft 0.3 UTILITY ?A2n&Name: Signature: cok Rating Compant: Date: r-�—�-�— 2/21/ I019 12:13 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 5 of 5 201t- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RODOLFO VEGA GUEST HOUSE Builder Name: RODOLFO VEGA Street: 5704 CITRUS AVENUE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: RODOLFO VEGA Jurisdiction: w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed �• walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation I a Class I vapor retarder with overlapping joints taped. shall be' permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. 1 Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. i Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building I shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed. fire sprinklers shall only be s rinklers p sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire spr D nkler cover plates and walls or ceilings - a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/21/2019 12:13 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 9 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1,. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 22.0 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 961 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 17.0 c) Area 7c. 95.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT 11 certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: � � '� Ize_!g,11 i� Date: 2 Jr / °I Address of New Home: 5704 CITRUS AVENUE City/FL Zip: FT. PIERCE, FL 2/21/2019 12:13:20 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 i wrightsoft® Project Su Job: ECOPY Date: En tire Hous L By: FQUICK CALCS, IN T I 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@,40L.COM Pr6ect Information I' For. RODOLFO VEGAGUEST HOUSE 5704 CITRUSAVENUE, FT. PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary �I Structure 12886 Btuh Ducts 2429 Btuh Central vent (0 chn) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 15315 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Hea961 Cool961 Area ffz Molume)(fN) 8649 8649 Air than esthour 0.45 0.23 Equiv.AVF (cfm) 65 33 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor j Static pressure Space thermostat 100 EFF 6.4 kW 219503 Btuh O 400 cfm 0.026 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 grAb Sensible Cooling Equipment Load Sizing Structure 12576 Btuh Ducts 3390 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin multipplier 0.95 Equipmensensible load 15167 Btuh Latent Cooling Equipment Load Sizing Structure 2185 Btuh Ducts 956 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3141 Btuh Equipment Total Load (Sen+Lat) 18308 Btuh Req. total capacity at 0.70 SHR 1.8 ton Cooling Equipment Summary Make Goodman Mfgg. Trade GOODMAN; JANITROL; Cond GSX140241L AMANA DISTI... Coil AWUF25XX16A AHRI ref 8631966 Efficiency 11.5 EER, 14 SEER Sensible cooling 15400 Btuh Latent cooling 6600 Btuh Total cooling 22000 Btuh Actual airflow 733 cfirl Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. .M,*• • wr7ghtsoft- 2019-Feb-21 11:52:19 .•�,�-«�-�, Right SUte®Uriversal201818.0.16 RSU08101 Page 1 ACCA...s\WrigttsoftHVAC\VEGA,RODOLFO-GUESTHOUSE.rup Calc=MJ8 Front Door faces: NE wrightsoft° Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@AOL.COM 1 2 3'' 4 5 ; Room name I E)posed wall Room height . Room dimensions Room area Entire House 134.0 ft 9.0 It 961.0 ft 171.0 BEDROOM 2 27.0 It 9.0 ft heaVocol 1.0 x 171.0 It iF Ty Construclion number U-value (Btuhf P-'o Or HTM (Btuh/M Area (it) or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Grass N/P/S Heat Cool Gross N/P/S Heat I Cool 6 11 --0 117 10 18 0 72 _0. 428 182 432 0_ 39 _--0 234 _ 705. 236 0_ V�I __D. 13A-4ocs 11DO-____ O ,_._+Y 13AAo s 1 D-c2ob _ 13A-4ocs 1DQob _ 13AAocs 1 D-c2ob 1 D-c2ob 4A5-2ob 22A_tpl 0.143 __0.390 0.143 0.650 n -n- a e �4.00 10.92 4.00 18.20 4.00 1820 4.00 18.20 18.20 15.68 0.90 2.19 10.3.4_ 2.19 70.51 261 237 _ 24. 292 7 949 _ 262 1169 910 519�18 -_248 639 3525 649 238 672 705 1058 420 0 --24. 342 50 107 1 0.143 _-0.650 0.143 0.650 0.650 0.560 _ s -s_ w w w w 2.19 _-23.80_ 2.19 70.51 70.51 41.95 '_ 1.601538 _ 261 10 342 10 15 10 961 251 2Q 307 1 2 1 _ _ 134 1005 182 1229 182 273 157 ___ 3711 108 _ 0 0 0 0 0 108 0 V�J 0 0 0 0 0 0 0 0 0 0 0 0 2a _-.`_0 �--G F , 171. 171 171. --15a 748 __27 6 0) AED exarsion 0 -140 Envelope lose/gain 10890 10109 2016 1349 12 a) Infiltration b) Room ventilation 1996 0 547 0 402 0 110 0 13 Internal gains: Occupants@ 230 Appliancestother . 4 920 1000 1 230 0 Subtotal (lines6to 12886 12576 2418 1689 14 15 Less odemalload Lesstransfer Redistribution Subtotal Duct loads 19% 27% 0 0 0 12886 2429 0 0 0 12576 3390 19% 27% 0 0 1 2419 456 0 0 1 1690 456 Total room load Air required (dm) 15315 400 15966 733 2875 75 2145 99 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �'}�- wrightsot't� 2019-Feb-21 11:52:19 Right SUte®Universal201818.0.16 RSU08101 Page 1 '� `...s\WrightsoftHVAC\VEGA,RODOLFO-GUESTHOUSE.rup Calc=MJ8 Front Door faces: NE *wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALLS, INC. 317 SIT LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height 1 Room dimensions Room'area BATH 5.0 ft 9.0 ft heaV000l 8.0 x 5.0 ft 40.0 ft2 BEDROOM 29.0 It 9.0 ft heat/000l 1.0 x 190.0 ft 190.0 ft2 Ty Construction number U-value (BtuhHt2-°F) Or HTM (Btuh/M Area (ft-) or perimeter (ft) Load (Btuh) Area (82) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 11 V�J 13A4ocs 11 D_0_, - 13A-4ocs 1 D- lob 13Aocs _1D c2ob 13A-4ocs 1 D-c2ob 1D-c2ob 4A5-2ob 166a30ad 0.143 0.390 0.143 0.650 W D.143 -,...,_. 0.650 0.143 0.650 0.650 0.560 0.032 n - n- a a s vs._ w w w .-,w , 4.00 10,92 4.00 ._ 18.20 4.00 18.20 4.00 18.20 18.20 _ 15.68 0 0,90 27.69 2;19 10.34. 2.19 _ 70.51 2.19 ,_._23.80. 2.19 70.51 70.51 41.95 160 _ _ 0.00 0 0 0 0. 0 LL 0 35 10 0 0, 0 0 140 � 182. 0 0 0 0 _36 - 138• 0 --0 0 0 77 23.8 0 0 0 0 64 18 __0 0 0 108 0 18 -0-0 0 0 1 108 0 72 39 . 0. 0 0 236 _ - 0 263 0 1058 0 __,._- 304 --_- 0 0 O 45 _� 10, 0 0 0 0 _� 40 40 0 0 432 0 _ - yJ C 0 0 0 0 _ 4-6 5 135 0 15 0 ...=_ 190 190 120 0 1 0 190 480 0 273 0 . _ 170 l�GG .0 0 29 -AR I I I 61 c)AEDexcursion -47 277 Envelope loss(gain 496 331 2231 2177 12 a) Infiltration b) Room ventilation 74 0 20 0 432 0 118 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 1 230 0 Subtotal (lines 6to 13) 571 352 2663 2525 14 15 Less extemal load Lesstransfer Redistribution Subtotal Ductloads 19% 27% 0 0 0 571 108 0 0 0 352 95 19% 27% 0 0 3 2666 502 0 0 4 2530 682 Total room load 1 Airrequired(dm) 679 18 446 20 3168 83 3211 147 to meet al I wriigMtsoft- Rigtt Sute®Uriversal 2018 18.0.16 RSU08101 slWrightsoftHVAC\VEGA,RODOLFO-GUESTHOUSE.rup Calc=MJ8 FrortDoor foes:NE 2019-Feb-21 11:52:19 Page 2 -;'wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email:OUICKCALCS@,AOL.COM 1 2 3 4 5 Room name E)posed wall Room height Room dimensions Room area A/C O ft 9.0 ft heall000l 3.0 x 3.0 ft 9.0 ftz BATH 2 O ft 9.0 ft heat/000l 5.0 x 8.0 ft 40.0 T Ty Construction number U-value (BtuhAF--°F) Or HTM (Btuh/M Area (ft2) or perimeter (ft) Load (Bluh) Area (T) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 11 13A-4005 11DO 13AAocs 1 D-c2ob 13AAocs 1D-c2ob _ 13A-4ob 1 Dt2ob 1 Dr1ob 4A5-2ob 0.143 0.390 0.143 0.650 n __n_ a a 4.00 —_10.92 4.00 1820 4.00 —_ 1820 8.20 18.20 18.20 15.68 i2.19 10.34. 2.19 70.51 — 2:19 _ 0 _ 0. 0 0_ 0 0 0 0 0 0. T O 0 0 _— 0 0 0 0 0 0 0. 0 __0' 0 0 0 0 0 0 0 0 0 0 VV��JJ —G. 0.143 0.650, 0.650 0.650 0.650 0560 s —s_ w w w w 0 0 0 0 0 0 0 0 0 0_ 0 —____ 0. 0 0 0 0 —.23.80 2.51 70.51 70.51 41.95 _0. 0 0 0 0 0 0 0 - 0 0 0 0 —.___0 0 0 0 00-0— __0 0 0 0 ._-0 0 0 0 — 0 0 0 b �— _ __ C [F _— 0 032 _ 0 90 1.60_ µ �0 ---A _,. 9 ----8, 1-4 40 40 0 36 0 — — — 64- 0 0 0 40 LIF ,----- I 6 C) AED emersion -2 -8 Ernelope losstgain 8 13 36 56 12 a) Infiltration b) Room %entilation 0 0 0 0 0 0 0 0 13 Internal gains Occupants@ 230 it Applianoes/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 8 13 36 56 14 15 Less exhemalload Lesstansfer Redistribution Subtotal Ductloads 19% 27% 0 0 -8 0 0 0 0 -13 0 0 19% 27% 0 0 2 38 7 0 0 3 60 16 Total room load Air required (dm) 0 0 0 01 1 1 45 11 76 3 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightMC 1t: 2019-Feb-21 11:52:19 .ft P. RighFSuteQtlUrdversa12D18 18.0.16 RSU08101 Page3 s\WrigtboftHVAC\VEGA,RODOLFO-GUESTHOUSE.rup Calc=MJB Front Door faces: NE i +wrightsoft° Right -A) Worksheet Date: Entire House Date: I' By: QUICK CALCS, INC. I I 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area LIVING 25.0 It 9.0 ft heat/ocol 1.0 x 261.0 It 261.0 T KITCHEN 10.0 ft 9.0 ft heat/000l 10.0 x 10.0 It 100.0 ff2 Ty I Construction number U-value (BtuhW--F) Or HTM (Btuh/R2) Area (W) or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 yJ V�J �--G I-- G rv13A-4as -11 W- 13A-40 s 1 D-c2ob 13A-4&s -1D-c2ob..:- 13A-4ocs 1 D- lob 1 D- lob 0.143 0.390 0.143 0.650 0143 .u-0650 0.143 0.650 0.650 0.560 n _n- a a , s -s_ w w w w 4.00 -1.0.92 4.00 18.20 4.00 - 18.20 4.00 18.20 18.20 15.68 2:19 - •10.34. 2.19 70.51 . 2.19 ._-23,80 2.19 70.51 70.51 41.95 AS -24 180 40 , ` 0 ___, M__,_0 0 0 0 0 21 24 84 .__ _ 262 561 728 0 �.---Q 0 0 0 0 46 248 306 28.20 0 ____,--!--0. 0 0 0 0 0 0 0 0 - 0 __ 0. 90 0 0 10 0 0 0 0..__. 0 _. -._0 0 0 140 3 m- 0 0 0 0 0 0 0 0 0 _0 0 0 0 0 0 w_-_0 175 0 0 420 80 0 0 1 320 0 0 157 _4A5-2ob 0.989 - 27.ti9 0.00 261_ _ _ 25 _ 692 _ 0 n 100 -----90; 277 160 0 100 10 i` I 6 c) AED excursion -214 -13 Envelope losstgain 2561 3625 844 741 12 a) Infiltration b) Room ventilation 372 0 102 0 149 0 41 0 13 I! Internal gains: Occupants@ 230 Applianoes(other 2 460 0 0 0 1000 I Subtotal (lines 6 to 13) 2933 4187 993 1782 14 15 Less odemal load Less transfer Redistribution Subtotal Duct loads 19% 27% 0 0 1462 4395 828 0 0 451 4638 1250 19% 27% 0 0 1 993 187 0 0 1 1783 481 i Total room load Air required (clm) 5224 1361 5887 270 1180 31 2264 104 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - wrlin tsoft- 2019-Feb-2111:52:19 RigttSUte4DUriversa1201818.0.16RSU08101 Page ''gy p`...s\WrightsoftHVAC\VEGA,RODOLFO-GUESTHOUSE.n¢� Calc=MJ8 Frord Door faces: NE I - wrightsoft° Right-JO Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 S,T. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 I Room name Exposed wall Room height Room dimensions Room area OFFICE 20.0 ft 9.0 ft heaHcool 10.0 x 10.0 It 100.0 ftZ UTILMY 18.0 it 9.0 It heat1cool 5.0 x 10.0 ft 50.0 ft2 Ty Construction number U-value (BlvhAl-°F) Or HTM (Btuh/M Area or perimeter (ft) Load (Btuh) Area (fF) or perimeter (ft) Load (Blvh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 VV��JJ =D_ 13A-4ots 11130 13A-4ocs 1D_c2ob 13A-40is ,Qt2ob 13A-4ocs 1 D[2ob 1 D-c2ob 4A5_2ob 1013&30ad-._._-_ 2A-h?1_ 0.143 0.390 0.143 ` 0.650, 0.143 _0.650 0.143 0.650 0.650 0.560 _.._. 0.032 0.989 - 197 98 ^___ 0 0 _- 0 59 0 0 0 -n - _n_ a e _ s _s- w w w _-w _ _ �_ ^ 4.00 10.92 4.00 ` 1820 4.00 _ 1820 4.00 18.20 18.20 ,_-15.68 0.90 27.69 2.19 _ 10.34. 2.19 70.51 2.19 23.80 2.19 70.51 70.51 - 41.95 ._-1.60• 0.00 90 0_ 0 -_ 0 - 0 ___0 90 10 0 0 10.0 - 100- J - 90 0_ 0 ___ 0 0 ---Q 80 1 0 0 T_ 100 - 20 360 0. _ 197 0 90 -----0 45 ----0. 0 --"D 27 0 0 0 90 -_-0 45 __. 0 0 360 0. 180 0 0 -__0 0 0 0 0, _t-G yJ - 0 -�0 320 182 0 0 _- 0 __0 175 705 0 0 _ --0_ 27 0 0 0 108 0 0 0- „ C _ F _ ----90 554 160 - „0 p --__50 _ _ , 50 50 18 _- __45 _ 498 _,_-80. _ 0 lam`, -m---_---•T �.- s _.....` - _-_- ..._.__. _ _. __._- __ _ _ -_ 6 c) AED excursion 206 -60 Eneelope lossigain 1506 1443 11921 374 12 a) Infiltration b) Room ventilation 298 0 82 0 268 0 73 0 1311 Internal gains Ooarpants@ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 1804 1525 1460 448 14 15 Less ekemalload Lesstransfer Redistribution Subtotal I Ductloads 19% 27% 0 0 0 1804 340 0 0 0 1525 411 19% 27% 0 0 -1460 0 0 0 0 448 0 0 FTTotal room load Airrequired(clm) 2144 56 1936 89 0 0 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ -Ord-- wr1gatvtso_ft- 2019-Feb-21 11:52:19 Right Sute® Universal 2018 18.0.16 RSU08101 Page 5 '��`...s\WrigksoftHVAC\VEGA,RODOLFO-GUESTHOUSE.rup CaIc=MJB Front Door faces: NE r v wrightsofto Duct System Summary o te: Entire House By. QUICK CALCS, INC. 317 St. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM For. RODOLFO VEGAGUEST HOUSE 5704 CITRUSAVENUE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowestfriction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.080 in/100ft 400 cfm 106 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.080 i n/100ft 733 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (dm) Design FR Diam (in) H x W (in) Duct Mati Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 446 18 20 0.080 4.0 Ox 0 VIFx 10.0 70.0 BATH 2 c 76 1 3 0.080 4.0 Ox 0 VIFx 2.2 70.0 BEDROOM c 3211 83 147 0.080 7.0 Ox 0 VIFx 7.8 70.0 BEDROOM 2 c 2145 75 99 0.080 7.0 Ox 0 VIFx 9.2 70.0 KITCHEN c 2264 31 104 0.080 6.0 Ox 0 VIFx 9.2 70.0 LIVING -A c 5887 136 270 0.080 7.0 Ox 0 VIFx 16.2 90.0 st1 OFFICE c 1936 56 89 0.080 7.0 Ox 0 VIFx 14.9 90.0 st1 Name Trunk Type Htg Mm) Clg (cfm) Design FR Meloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 192 359 0.080 457 12.0 0 x 0 VinIFIX Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1' I Ox0 400 733 0 0 0 0 Ox 0 VIFx Boldritalic values have been manually overridden i Ak wrightsoft® 2019-Feb-2111:52:20 IS— Right-SLite@Urtversa12Ol8 l8.0.16 RSU08101 Page 1 /CCK ...s\WrightsoftWAC\VEGA,RODOLFO-GUESTHOUSE.np Calc=MJ8 Front Door faces: NE