Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2Q178tLucie6690t1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business•and,Professional Regulation - Residential Performance Method Project Name. DEDRICK"RESIDENCE Builder Name: BROOKVILLE HOMES, INC. Street: 2314 ATLANTIC BEACH BLVD. Permit Office: ST LUCIE COUNTY City, State, Zip: FORT`PIERCE , FL, 34949 Permit Number: Owner Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate -Zone 2 ) III1. New. construction or existing New,(From Plans) 9. Wall Types(2629.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a: Concrete Block,- Exf Insul, Exterior R=4.1 .2310.70 ft? 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 319.00 ft' c. N/A R= fit' 4. Number of Bedrooms, g d.'N/A R= 5. Is this a worst -case? No 10. Ceiling Types (2329.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 .2329:00 ft' 6. Conditioned Floor,area above•grade (W) 2329 b. N/A R= fit' Conditioned floor area below grade (ft') 0 c. N/A R= fitI 7. Windows(314:0 sgft.) - ', Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft' 6 200 a. U-Factor: Sgl; U=0:65 246.00 ft- SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.70 68.00 ft' 12. Cooling, systems kBtu/h'r Efficiency SHGC: SHGC=0.30 a. Central. Unit 47.0 SEER:16.00 c. U-Factor: N/A ft' SHGC: i 13. Heating systems kBtu/hr Efficiency ' d. U-Factor: N/A ft' a. Electric Strip Heat -X'0, COP:1.00 SHGC- Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0:261 14. Hot water systems 8. Floor Types (2329.0 sgftInsulation Area a. Electric Cap: 40, gallonsJ 'EF: a. Slab -On -Grade Edge'Insulation R=0.0 2329.00 f4' b. Conservation features 0.980 b. N/A R= ft' None ci N/A R= ft' 15. Credits None Giass/Floorkea: 0.135 Total Proposed Modified Loads: 81.79 PASS Total Baseline Loads: 82.08 I hereby,certify that the,plans and specifications covered by Review of the plans and ��-vUE STATE this calculation'are•incompliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPA D B • Before construction is completed o DATE:, - this building will be inspected for compliance with Section 553.908 *� herebycertify that'this building, as designed, is in'com liance fY 9� 9 � pCOb:WE Florida Statutes. - with the Florida'Energy � O.WNER/AGiENT BUILDINGOFFICIAL: DATE: DATE: . - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifles�as certifledfactory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1..1-arid t itl is projectirequire an envelope leak'age%teM report with envelope leakage no. greater than 7.00 ACH50 (R402.4:1:2) 7/18/201610:09 AM EnergyGauge® USA Section R405.4.1 Compliant Software F11 r�trt. en$ i i ; i,'a, ^_ Page 1-0 1 " ." . Z! co � � � CD 19 0- CD CD cil 0.1 Ki co cn co co CA PC C. cr co cc CD ccl ID Ao CD 0 Ago AD FL FORM'R405-2017 INPUT RUMMARY r.I4Fr.K1_IRT RF_Pf)RT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade. Edge Insulatio MASTER BEDRO 33 ft 0- 292 ft2 — .0 1 0 2 Slab -Oh -Grade _Edge Insulatio M W IC ,1 '5 ft 0 35 ft= — 0 1 0 3.SIab=On-Grade .Edge, Insulatio M WIC 2 1 it 0 35.ft2 — 0 1 0 4 Slab -On -Grade. Edge Insulatio TOILET 4 ft 0 24 ft= _ .0 1 0 5SIab-On-Grade Edge Insulatio MASTER.BATH 40_ft 0 177 ft2 - 0 1 0 Ii II '6 Slab -Oh -Grade Edge- Insulatio FOYER .9 ft 0 69 ft2 — 0 1 0 `I 7 Slab On -'Grade Edge Insulatio, DEN 12 ft 0 1241ft2 _ 0 1 0 8Slab-On=Grade Edge Insulatio .PANTRY f ft 0 14AF — 0 1 0 9 Slab -On -Grade Edge Insulatio DINING ROOM 13.9 ft 0 208 ft2' — .0 1 0 10SIab-On-Grade Edge Insulatio KITCHEN 6 ft 0. 242 ft2 — 0 1 0 11Slab-On-Grade Edge Insulatio FAMILY ROOM 231t 0 302 ft2, — 0 1 0 12SIab-On=Grade Edge, Insulatio LAUNDRY 1 8 0 61 ft2, — 0 1 0 13SIab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 156 ft2 • — 0 1 0 14SIab-On-Grade Edge Insulatio CLST2 2 ft 0 18 ft2 — 0 1 0 15SIab-On-Grade Edge. Insulatio BATH,2 8-ft 0 72 ft2 — 0 1 0 16SIab-On-Gr6de Edge Insulatio BEDROOM 3, 11 ft 0 1,43'ft2 — .0 1 0 178Iab-On-Grade Edge, Insulatio HALL 1 ft 0 32 ft2 — 0 11 0 18SIab-On-Gra6e; Edge Insulatio CLST 3• 2'ft 0. 14 ft2 — 0 1 0 II `I li 19SIab-On-Grade, Edge Insulatio CLST 4: 1 ft 0 12..ft2 — 0 '1 0 20SIab-On-Grade Edge Insulatio BEDROOM'4 26 ft 0. 169.ft2 — 0 1 0 21SIab-On-Grade. Edge Insulatio BATH 3 19 ft 0 90 ft2' — 0 1 0 22SIab-0n-Grade; Ed9e Insulatio HALLWAY 4 ft 0 40 ft2• — 0 1 0 ROOF Roof Gable Roof Solar SA, Emitt Emitt Deck, Pitch V # Type Materials Area. Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 266511:2 .0 ft2 Medium 0.5 No 0:9. No . 0 26.6 ATTIC V # Type Ventilation. Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 360 2329 ft2 N N ;I 7/1812018,10:09 AM EnergyG'auge® USA Section 'R405:4.1 Compliant Software. Page 3 of 7 o o CD C, Q• 0 0 Q m pp pp pp Dp pp pp Dp pp pp 9p pp a In to Lq IQ IQ IR Lq Ui Iq UO U) U) a; 10 cs to c; to: 'd W) 6' u-i c; Aq 0 cc 0 CS Q, p 0 d c) 0 3' 3: B: O-P 0 o 0 a ,o 0 c? 40 CD, 'o 0 LL LL co C5 6 6 cs CS o o o C. a 0. o C3, CD. CD CD 'd 'CS CS CS MI 19 Q 0 0-0 0 0 a 0 0 0 CD a IL U) Cl> r'. 11 co cl Q 'CR 0 "R: co M (I O. i-- cl, C-4 co CM 'CO C3. 0 -i td 6, Z6 qD F% CD 5: it co'OD- co co cq -z v a 't r. co m -Im C Ea- m in- rxi W m m Hi 0 in-, W M Hi rxi m co ca m C3, 0 (a 0 0 0 'a. 0, J 3: Lo v CD '(w cm, !t co co m 64 'C4. co, z .0 ILI 0 g 0 c) m C.) m co cn C.? 6 m g -V) 6 g C!) C) 6 C.? 0 m g 4�3r 0, Co T- -- — — — — — — — O Z., M -Nr0, co m co ca 0 z 0 .0 Z. C, C.4 0. I W 7- C4 co LU z 0 W. 0 0 0 N. i� C� X 0 L) w a: 0� z w w 0 M 0 ,LJ W. z M. C-) ? Z '0' w 1. o -J. CO 0). 0, �1- �-j m LLI w -i w w LLI w z j o CL Ul uj < z X 0 0 co) m co eL m w in. 93 w LU LL < cl L 5 L co in w 'o w c a a r a U3 C. 'A :r_ lu W LU �d. B. sA, B -se 3 be be 3 -m N �:ig 8 .3, 3 3. 3. B Y B -k' 3 m" m m In m mm Ea m, m co m m M In m ED In `3 - 1-3 3 38 :a S 0 '6- CD mm a), �D 4) W D 4) 0 IV 'a) 4) 4) 41 5 9 ED (D i t 0 E (D 0 ro-, Q Q S. C) �L) S Cj 0 r- - OL •'r ,NO a c . 5 a C3 0, 0 C3 "o- L) 0 0 r- or- C.) C.), -Co. 0 0 0 Ll 0 0 0 : 8 0 C.) .0 Q 96 0: C3 C.) .0 ;o 43 .2 .2 0 m .2 0 L) 1 'a) 4) 'o .0 o -- .5. CC) - Z5 t ts ti ti -Z5 C r- a c r- c c c c r_ r_ C. c C C c C C 13 r- v r_ 10 C C = CD - - a). a) 'Io- W ID 4) 0) L 0 D n. D D D o. :D w Uj Uj W. w C14 CD 'r Lf) W r- OD 0 E-W Co '(0 Z' W �2: U) 0) Lu p Z, z z N. Cl)- It LO W. � 6D 6 — — — C4 co Im .0 "r. to tp Is CO C5 LLI I r- ;z n c Lr -C a LL O O O .O O O O OO C tD O O lD O to O O O O O O O C O C O C O C O C O t •O C O C O C O O CC O O O O 133 ` 00 Z Z Z Z Z Z N O 10 t0 O In l0 LO t0 tq c co ' c mm 9 o m m N ai -a) 0 N 2 �O 0 m 4) S co c M. C O C CC OO O O OO C .T C O c O - t0 N to N Z- ZZ Z Z 'ZLO Z Z LL t c. C C C 'c C C C C C C C c c C LL tD c C c c c 'C :C C c c c c C ,C •C =. " (? �.. a a a v � a' st d' It m r` M Cd 51 M. m. O v M r` O of Cl) n m p . Z:- C• Z: C __ W �. > co O 07 �. .a_ d. Co. , pp- ap O O O O O C, 0'0 6 O6 O O -O O O O-• �� .M (D: N M 'CS co — N Q x _ O) O) O) 'O 0) T. W N O € 8 ,E z' Z z Z; Z Z Z Z Z Z Z z Z Z m. . O O O O" O O O — O _ Z - •N .a... ? N m O O ..� N. C �" d Ci N N N N, N N 'ci N• N N N. N G O C- O , co M: ' 17 Q N to 10 t0 t0- (O to- t0 i0 .t0. t0 t0 r 'U) t0 t0- t0 to t0 _N W .b to b (0 'd C:;o C:;, o C) o o 'o o_ o o v v D W O M Ch } .Q N } p Z F-. O O=_ F, m U m rn `� m `�' 4 `�' m WO C .^y Lo, O O O —CD O O O d O O O O, O, O- O O 0)C) o) O)': D o CD O) cm (� Y Y - d CCNO) C (n C V) C co C' (I) f "0) ( ) tl C N C co) C (n(0) C ' mm m m d W W W; W W W W W W W W W W W 40 #. 0, # O. } - -LLLL A A (D lJ� � J J LL O . " COl O A N t0 'Co O 41 t0 �N N N O LL Q C7 C9: C9, W W W 'u) ' OE •W N u) 3 W (q' Z Z •Z• LL! A W z z w w "vz ui (n � " z .- . 4t N N N 'N. N- N co N-- LLI- r. O _ to Of.. a. _ Q - c N' col r Gnvnn QAnr;_')n17 IIUDI IT _CI:IMMADV 1-_141=rW1 ICT R.FPL'lRT INFILTRATION # Scope Method SLA CFM 50 ELA -,EgLA ACH ACH 50 1 'Whoiehouse Proposed ACH(50) .000449 27442 150.65 283.3.2 .349 7 HEATING SYSTEM # System' Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None: COP:1 34 kBtu/hr 1 sys#1 I, COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 47 kBtu/hr 1410 cfm 0'.8 1 sys#1 HOT'WATER-SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40, gal '80.9 gal 120 deg None 'SOLAR HOTWATER SYSTEM FSEC Cert # Company Name Collector Storage System, Model # Collector Model # Area Volume; FEF None None ft' DUCTS —Supply — V # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 200 ft? Attic 20 ft' Default Leakage Garage (Default) (Default). 1 1 TEMPERATURES, Progiamable Thermostat: N Coolirig Jan Feb Mar Heatin an Feb Mar Venting Jan .Feb N Mar Ceiling Fans: pr May Jun Jul Aug Sep Oct Nov 'Apr May Jun Jul Aug Sep Oct Nov WprIIMay n Jun n Jul Aug 11 Sep Oct N Nov Dec Dec Dec �i I 7110/2018110:09 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 :of 7 N Oc.' Oc coo 00 Co .- co mr� mm mm om 006 mm com oorn wr, tom mm ,O H W _m } 00 0 W O N .0. CV. N eo sf g -M Q O OCD Wt- OOD.. cm c00 �cpm m` m a U Z S � 0 F- S 0 0. .S Wr- wp g J of Q' oo ui z m v m W :W g 0 0 o= .v o 4� 0 LL m m m O1 0� co oo 'Imcm 0000 WW COr.t. CO cc raM cc ,mm " C000 mm C O U LL co Co m m q vh .M to cq t0 co q co q ch q 00 M c; Ci Cal co m C C "C C C 0 0 'C C C C 'C C, C .0 O O O O .01 C f` caC' r•� 0000 r•� Inm, cowmm mC6 .0 , N C m Coco ter. 'Coco rnr- tnco- mm; inco tom c cc fir` 'CO f`�. Inc tDcO Inco mm H . G H WO, ACo - c0. f-OO tnc WCR Inc wp - .M .c0 nm c0 nm to CO mm to mm :Q :O: ,•'�- �. . � w- �' �' .� r= � i' �'. yam+ � _ �" ,� .� � S-' � CL' N' _c0 t`m cC, nao Inc w<o mm com N • r COO -coo tnm La CO r-co' rnoo tom (DW 0 o lu 47 v. o ¢ c Q: c IT . Cr c c `c Q Ci, ' Q c o• of cr -Ol N (0, W,. fq to N W H) O! co ur 'N c0. rn U) (o ca 'A N .. H _ COL Wr av OD- av' 00 Ova. m. EO maw a� m' c0 ay. co Ov 00 U0l .m �+ _ O' w _ W �T to to m m m to m m to to . m w to _ R _ 3 to �' �: m. �. d .m C. 0 0 0..0 0 0 0'0 o p 0 0 0 0 0 0 :0_0_-0-0 -. C C C C C S. C Q: U 0 w m N 2017 - AIR BARRIER AND INSULATIOWINSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR. BARRIER.AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DEDRICK RESIDENCE Builder Name., BROOKVILLE HOMES, INC. Street: 23,14 ATLANTIC BEACH BLVD. Permit Office: . ST LUCIE COUNTY City, State; Zip: FORT PIERCE, FL, 34949 Permit Number: U Owner. Jurisdiction: ST LUCIE COUNTY W. Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER -CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed lin the building envelope. Air-perrrieabie insulation shall requirements The exterior thermal envelope' contains a continuous air barrier. Breaks not be used as a sealing material. or joints in the air barrier shall'be sealed, Ceilinglattic The -air barrier in any dropped, ceiling/soffit_shall be aligned with the The insulation in an dr ed /soffit y dropped ceilin g insulation and any gaps, in ths,air. barrier.shall,be sealed. shall be aligned with the'air barrier. Access;openings, drop downstairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities -within comers and headers of 1rame walls The junction of the top plate and'the 'top of exterior walls' shall be sealed. shall be insulated by completely filling.the cavity with a Knee walls shall be sealed. material having a thermal resistance,of R-3 per Inch •minimum. Exteriorthermal envelope insulatiomfor framed walls shall'be'installed in sub'stantiai'contact and continuous alignment with the air barrier. Windows, skylights The space. between window/door.jambs'and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include.the air barrier. Rim joists shaltbe insulated. Floors' The, air barrier shall be installed at any exposed edge of, insulation. Floor framing cavity insulation shall be installed to (including, maintain permanent gontact with the underside of -above-garage subfloor decking, or floor framing cavity insulation shell and cantilevered floors) be Permitted to be In contact with the,top side of sheathing, or continuous insulation• installed on the underside of•floor framing and extends from1he bottorr to the top of,all•perimeter floor framing members: Crawl space walls Exposed earth in unvented crawl.spaces shall be covered with a Where.provided instead of floor insulation, insulation Class [vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility+penetrations, and -flue shafts opening to exterior or unconditioned's ace shail,be sealed. Batts in narrow cavities shall be cut to fit; ornarrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms, to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned. spaces. Recessed lighting Recessed.light fixtures installed in the building thermal. envelope shall Recessed light fixtures installed -in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt'Insulation shall be cut neatly to fit around wiring a plumbing inexterior walls, or insulation that on installation readily conforms to available.space shall extend behind plblnq and wiring. Shower/tub The air barrier installed at exterior walls adjacentto showers and Exterior walls adjacent to showers and tubs -shall be on exterior wall tubs shall separate'them from the showers and tubs. insulated, Electrical/phonebox on The air.barder shall be installed behind electrical or communication :exterior walls boxes or -'air -sealed boxes shall be installed. HVAC register boots HVAC,register boots that penetrate building thermal envelope shall be. sealed`to the sub -floor or drywall. .Concealed When required'to be sealed; concealed fire sprinklers shall only be sealed sprinklers I in a,manner that is recommended by the manufacturer. Caulking or other adhesivesealants shall not be used to fill voids between fire sprinkler i cover' 16tes.a d walls or, ceili s a: in aouiuun; mspecuon or log walls snau•oe in accoraance Ham ine provisions or ict;-4uu. 7118/201810:10 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 I 2017 EPL DISPLAY -CARD ENERGY PERFORMANCE LEVEL (EPL):DISPLAY CARD ESTIMATED ENERGY'PERFORMANCE INDEX* ='100 The lower the Energy .Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12.. Ducts, location & insulation level. a) Supply ducts R 6.0 2. Single-family or multiple -family 2.. ;Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3: No..of, units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity '47.0 a) Sol Usystem SEER 16.0 5.,Is this.a worst case? (yes/no) 5; No b) Single package. SEER' c) Ground/water source SEER/COP 6. Conditioned,floor.:a(ea'(sq. ft.). 6: 2329 d) Room unit/PTAC EER e) Other 7. Windows,-tyowand'area a) U-factori(welghted average) 7a.. 0:661 b) Solar Heat Gain Coefficieni:(SHGC) . 7b. 0.261 14. Heating system: Capacity 34:0 c)-Area 7c: 314.0 a), Split. system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:{weighted average) i8a. NA. d) Gas furnace, natural gas AFUE b) Solar'Heat Gain Coefficient (SHGC) 8b. NA e), Gas•furnace, LPG AF.UE f) Other' 9: Floor type, insulation level: a).Sleb-on-grade (R-value) 9a. 0.0 b) Wood; raised (R-value) 9b. 15. Water heating system c) Concrete, ,raised (R-value) 9c. a) Electric resistance 'EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas flred, LPG EF A. Exterior-: d)=Solar system with tank EF 1. Wood frame (Insulation R-value) 1OA1: e) Dedicated heat pump with tank EF 2., Masonry (Insulation R-value) 1OA2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood'frame (Insulation R-value) 10RI.- 2. Masonry (Insulation R-value) 10132. 16.,HVAC credits'claimed (Performance Method).. 11-Ceiling type and insulation level a)•Ceiling fans a) Under. attic 11 a. 30.0 b) Cross ventilation 'No b) Single,assembly 11b: c) Whole house fan No c) Knee�walls/skylight walls 11c. d)'Multizone cooling credit d)' Radiant barrier installed 11 d. No e)'Multizone heating .credit f) Programmable thermostat No "Label required by',.Section'R3011.3 of'the Fiorida;BuildingCode, Energy Conservation, if not DEFAULT. I certifythat thl&home:has complied with'the,Florida, Building, Code, Energy Conservation; through the -above energy saving features which will be installed (or'exceeded) in this home before final inspection. Otherwise, a new EPL display card will 'be completed based on installed code eom liant features. Builder Signature:, Date: Address of- New. 'Home: 2314 ATLANTIC BEACH BLVD: it I1 ` City(FL Zip: FORT PIERCE., FL 34949 7/18/201810:10:21 AM EnergyGauge®;USA 6:0:02-;FlaRes2017 FBC 6th' Edition (2017) ConipliantSoftware Page 1 of 1 r ++-F- wrightsoft, Project Summary Entire House QUICK CALCS, INC. ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: OUICKCALCS@AOL.COM • For: Notes: DEDRICK RESIDENCE, BKV HOMES 2314ATLANTIC BEACH BLVD., FORT PIERCE, FL Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 31354 Btuh Ducts , 8422 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping , 0 Btuh Equipment load 39776 Btuh Infiltration Fort Pierce, FL, US Method Simplified Construction quality Average • Fireplaces . 0 Heating Cooling Area (ft2) 2329 2329 Volume (ft3) 23506 23506 Air changes(hour 0.32 0.16 Equiv. AVF (cfm) 125 63 Heating Equipment Summary Make 'Trade ,Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat I 100 EFF 10.4 kW 35383 Btuh 21 OF 1567 cfm 0.039 cfm/Btuh 1.00 in H2O Job: Date: MARCH 22, 2018 By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative_ humidity . 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure`" 34905 Btuh Ducts 733 Btuh Central vent (0 cfm) 0 Btuh Blower I I 0 Btuh Use manufacturer's data Rate/swing multiplier n 0.95 Equipment sensible load 33857 Btuh Latent Cooling Equipment Load Sizing Structure I 4018 Btuh Ducts 3336 Btuh Central vent 0 cfm) 0 Btuh Equipment latent load 7355 Btuh Equipment total load 41211 Btuh Req. total capacity at 0.70 SHR 4.0 ton Cooling Equipment Summary Make Carrier Trade Cond CA16NA0480000A Coil FX4DNF061 AH R I ref 7893753 Efficiency 13.5. EER, 16 SEER Sensible cooling 32900 Btuh Latent cooling 14100 Btuh Total cooling 47000 Btuh Actual air flow 1567 cfm Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of _ i4 + Wrl9h'tsoft� Right -Suite® Universal 2017 17.0.08 RSU08101 ...rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Calc = MJ8 Front Door faces: W opx 2018-Mar-22 10:13:49 Page 1 + wrightsoft, Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: OUICKCALCS@AOL.COM Job: Date: MARCH 22, 2018 By: 1 Room name Entire House MASTER BEDROOM 2 F)posed wall 231.0 It 33.0 it 3 Room height 10.1 ft d 10.4 ft heat/cool 4 Room dimensions 1.0 x 292.0 It 5 Room area 2329.0 ft2 292.0 ftz Ty Construction number U-value (BtutVftz°F) Or HTM (Btuh/ft2) Area (ftq or perimeter (it) Load (Btuh) Area (ftq I or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 0.143 n 4.00 255 583 547 2189 1392 j 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 n n 18.20 18.20 14.99 14.99 6 30 0 0 109 546 90 450 0 0 0 0 0 0 0 0 VVV[ 13A-4ocs 0.143 a 4.00 2.55 590 492 1968 1251 I 166 130 522 332 11, 2 glazing, clr low-e 0.650 a 18.20 33.77 45 0 819 1520 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 36 0 655 1216 36 0 655 1216 2 alezina. clr low-e 0.650 a 18.20 33.77 18 0 320 593 0 0 0 0 13A-4ocs 0.143 s 4.00 255 721 601 2406 1529 177 147 588 374 2 glazing, clr low-e 0.650 s 18.20 14.99 12 12 218 180 I 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 60 60 1092 899 30 30 546 450 2 glazing, clr low-e 0.650 s 18.20 14.99 48 48 874 720 f 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 396 300 1201 764 I 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 12 0 218 405 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 36 0 655 1216 0 0 0 0 11D0 0.390 w 10.92 11.31 48 48 524 543 0 0 0 0 C 16B-7ad 0.112 3.14 5.88 2329 2329 7304 13695 292 292 916 1717 F 22A-tpl 0.989 27.69 OAO 2329 231 6397 0 1I 292 I I I I 1 i I 33 914 0 6 c) AED excursion 0 -115 Ernielope loss/gain 27496 26462 I 4141 3973 12 a) Infiltration 3858 1033 578 155 b) Room ventilation 0 0 i 0 0 13 Intemal gains: Occupants @ 230 2 460 1 2 460 Appliances/other 16950 1500 Subtotal (lines 6 to 13) 31354 34905 I 4719 5088 Less mdemal load 0 0 �I Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 31354 34905 I 4719 5088 15 Duct. loads 27% 2% 8422 733 271% 29/6 126E 107 Totallroom load 39776 35639 5986 5195 Air required (cfm) 1567 1567 I 236 228 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. r _ wrightsoft- Right -Suited Universal 2017 17.0.08 RSU08101 Il 2018-Mar-22 1 :1139 ...rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Calc = MJ8 Front Door faces: W Page CD N N N 2 U 2 Q 2 O U O 0 m U J U Y U 7 O LU 0 N s 11 N00000000000000t80 42 N <tO 00 OOOnN p cV a g L � N n fD O O O O Nv O O y T N N O = �4 x �� rn00000000000000�� 0 d �m o "E rn0000000000000022 o R `o U -- — _ _—_--- 0000000�0000000c80 T 02 NO 00 O� 000m1, 2 T N Cl) C f 8 y'� �� 0000000�00000000� V WO f0 to 000f0o) N cr7 �N{N (O o ui U= = " �0 � 0o00000goo000008LO O d ri O 'N� 000-000,;0000000�M o u'1W W �n Ic��Icc����W W �n fc•��(h WO 8 N�r-Nm mC�N�r��c9mr�G �� p pp pp pp pp p pp oo pp pp pp pp�� SNNONNNSNNNONN�rfD _� ppM N CCCVVVV R OD w s{ w c6 w a w a6 w g w w C C7N 2 �s � cQQctcc�� dQQdQQdQQdrnQQNQQN rQQn3QQ3Q53yy�3 � Q� �'�. 000000cc000000000 U � 66 O)N N N N NN N N N O UU U UU U U U U � � w F5 U U yg_'g_w_�'mgwm9)gwgm_E' o C �,Lo •� O CD � �E �- E 3�°'`0 C Uc �o�o��oirnoa o�wo�i�, rno�0� NN NNN+-NNN NNr ' � � E � �L'O E E EE � "Q� " C¢ Q ¢ ¢ Q H 1�C�II1�CII�CII� U - ro a v�i °� ¢ !° d N m_-It LO o - `° �r O N M N co 0 N .7 n 0- 0 W a w N 0 y 2m �n W 'w ¢w k Q }� Y W L ° Q Sow w O + wrightsoft° Right-JO Worksheet Entire House QUICK CALCS, INC. 317.ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: OUICKCALCS@AOL.COM Job: Date:' MARCH 22, 2018 By: ti Room name TOILET MASTER BATH 2 31 Exposed wall Room height 4.0 ft 9.4 It heat/cool 40.0 It 9.4 ft heaUcool 4 5 Room dimensions Room area 6.0 x 4.0 1t 24.0 1? 1.0 x 177.0 it 177.0 ftz Ty Construction number U-value (BtuWftz°F) Or HTM (Btuh/W) Area (ftq or perimeter (ft) Load (Btuh) I Area (ftq or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool I Gross N/P/S Heat Cool 6� 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 n n n 4.06 18.20 18.20 2.55 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 122 0 0 122 0 0 489 0 0 .311 0 0 11 13 ,flocs 2 glazing, cir low-e 0.150 0.650 a a 4.20 18.20 255 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 , 2 glazing, cir low-e 2 alazma, clr low-e 13AAocs 0.650 0.650 0.143 a a s 18.20 18.20 4.00 33.77 33.77 255 0 0 38 0 0 32 0 0. 127 0 0 80 0 0 85 0 0 85 0 0 339 0 0 215 2 glazing, clr low-e 2 glazing, cir low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 6 0 6 0 109 0 90 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 13A flocs 2 glazing, cir low-e 0.650 0.143 0.650 s w w 18.20 4.00 18.20 14.99 2.55 33.77 . 0 0 0 0 0 0 0 0 0 0 0 0 0 169 12 0 157 _ 0 0 629 218 0 400 405 2 glazing, cir low-e 11DO 0.650 0.390 w w 18.20 10.92 33.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G 166.7ad 0.112 3.14. 5.88 24 24 75 141 177 177 555 1041 F 22A-tol 0.989 27.69 0.00 24 4 111 0 177 40 1108 0 �I I i i I it it 6 c) AED excursion -7 I 101 Errvelope loss/gain 422 304 I 3339 2474 12 a),; Infiltration 63 17 I 633 170 b) ; Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 I 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 485 321 I 3972 2644 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 27°/ 2% 485 130 321 7 2T/o 2% 3972 1067 2644 56 Total room load Air required (cfm) 615 24 328 14 I 5039 199 2699 119 +V- wrlghtsoftm Right -Suite® Universal 2017 17.0.08 RSU08101 ,45tN ..;rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Calc = MJ8 Front Door faces: W 2018-Mar-22 10:13:49 Page 3 +I+ wrightsoftRight-JO Worksheet I Job: Entire House Date: MARCH 22, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: OUICKCALCS®AOL.COM 1 Room name FOYER I DEN 2 3 Eqx sed wall Room height 9.0 ft 10.8 ft heat/cool I 12.0 ft I 10.8 It heat/cool 4 5 Room dimensions Room area 1.0 x 69.0 ft 69.0 ft2 1.0 x 124.0 ft 124.0 ftz Ty Construction number U-value (BtufditZ°F) Or HTM (Btuh/ftq Area (ftq or perimeter (ft) Load (Btuh) Area (ftq I or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-4acs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 n n n 4.00 18.20 18:20 255 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 I 0 I 0 0 0 0 0 0 0 0 0 0 0 11 13A-4ocs 2 glazing, clr low-e 0.143 0.650 a a 4.00 18.20 2.55 33.77 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 clazino. clr low-e 0.650 0.650 0.143 a a s 18.20 18.20 4.00 33.77 33.77 255 0 0 0 0 0 0 0 0 0 0 0 0 0 I 0 I 0 0 0 0 0 0 0 0 0 0 N13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 0.650 0.650 0.650 0.143 0.650 s s s w w 18.20 18.20 18.20 4.00 18.20 14.99 14.99 14.99 255 33.77 0 0 0 97 0 0 0 0 49 0 0 0 0 197 0 0 0 0 125 0 0 0 0 130 0 0 0 0 94 0 0 0 0 375 0 0 0 0 238 0 2 glazing, clr low-e 11DO 0.650 0.390 w w 18.20 10.92 33.77 11.31 0 48 0 48 0 524 0 543 36 0 0 0 655 0 1216 0 C 1613-7ad 0.112 3.14 5.88 69 69 216 406 1 124 124 389 726 f 22A-tol 0.989 27.69 0.00 69 9 249 0 I 124 I 1 i I 12 332 0 6 c) AED excursion -47 423 Envelope loss/gain 1187 1027 1751 2606 12 a) Infiltration 164 44 218 58 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 I 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 1351 2071 I 1969 2665 Less external load 0 0 I 0 0 Less transfer 0 0 0 0 Redistribution 0 0 14 26 14 Subtotal 1351 2071 1984 2691 15 Duct loads 279% 20/6 363 43 27 0 20/6 533 57 Total room load 1713 2114 2516 1 2747 Air;required (cfm) 67 93 I 99 121 �' Wrighl:soft- Right -Suite® Universal 2017 17.0.08 RSU08101 AGCA rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Cale = MJ8 Front Door faces: W 2018-Mar-22 10:13:49 Page 4 • 9 wrightsoft° Right-JO Worksheet Entire House QUICK CALCS, INC. 317,ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS®AOL.COM Job: Date: MARCH 22, 2018 By: 1 Room name PANTRY DINING ROOM 21 Exposed wall 0 ft 14.0 it 31 Room height 10.4 it heat/cool 10.8 it heat/cool 4 51 Room dimensions Room area 6.0 x 2.0 ft 12.0 ft2 1.0 x 198.0 ft 198.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) I Load number (Btuh/ft2-0F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool I Gross N/P/S Heat Cool 61 11 yJ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 1- flocs 2 glazing, clr low-e 6.143 0.650 0.650 0.143 0.650 n n n a a 4.00 18.20 18.20 4.00 18.20 . 2.55 14.99 14.99 255 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 151 30 0 0 0 121 0 0 0 0 485 546 0 0 0 309 1013 I 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 olazm0. clr low-e Blazons 0.650 0. a s 18.20 4. 33.77 255 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650650 s 18.2020 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 13A-4ocs 2 glazing, clr low-e 0.650 0.150 0.650 s w w 18.20 4.20 18.20 14.99 255 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 . 0 0 0 11130 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 C 1613-7ad 0.112 3.14 5.88 12 12 38 71 198 - 198 621 1164 F 22A-tpl 0.989 27.69 0.00 12 0 0 0. 198 14 388 0 6 c) AED excursion -2 I -2 Envelope loss/gain 38 69 I 2040 2484 12 a) Infiltration 0 0 I 255 68 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 10 0 Appliances/other 0 600 Subtotal (lines 6 to 13) 38 69 I 2295 3153 14 Less extemal load Less transfer Redistribution Subtotal 0 0 -38 0 0 0 -69 0 0 0 0 2295 0 0 0 3153 15 Duct loads 27% 2% 0 0 27% 2%1 616 66 Total room load Air required (cfm) 0 0 0 0 I 2911 115 3219 142 f' WrigF7tsoft' Right -Suite® Universal 2017 17.0.08 RSU08101 .9CCA ,I rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Cato = MJ8 Front Door faces: W J 2018-Mar-22 10:13:49 Page 5 a' +1+ wrightsoft` Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: OUICKCALCS@AOL.COM Job: Date: MARCH 22, 2018 By: I Room name KITCHEN FAMILY ROOM 2 Exposed wall 8.0 ft 18.0 ft 3 Room height 10.8 ft heat/cool 10.8 it heat/cool 4 5 Room dimensions Room area 1.0 x 256.0 ft 256.0 it2 16.0 x 18:0 it 288.0 R2 Ty Construction number U-value (BtuMft2-°F) Or HTM (Btuh/ft2) Area (ft2 or perimeter (ft) Load (Btuh) Area I or (ft2) perimeter (it) Load (Btuh) Heat Cool Gross N/P/S Heat Cool I Gross N/P/S Heat Cool 6' VL1 13AAocs 0.143 n 4.00 255 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0. 0 0 0 0 0 I�-GG 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 V 2 glazing, clr low-e 2 glazing, 0.650 0.650 a a 4.00 18.20 255 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 Olazina, cir low-e... . 0.650 a 18.20, 33.77 0 0 0 0 0 0 0 0 V 13AAocs 0.143 s 4.00 2.55 86 38 154 98 194 164 658 418 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 30 30 546 450 2 glazing, clr low-e 0.650 s 18.20 14.99 48 48 874 720 0 0 0 0 Vh13AAocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 C 16e-7ad 0.112 3.14 5.88 256 256 803 1505 288 288 903 1693 F n i i 'I ii i 22A-tpl 0.989 27.69 0.00 256 8 222 0 288 18 498 0 6 c) AED excursion -104 I -59 Envelope loss/gain 2052 2218 I 2606 2503 12 a) Infiltration 146 39 328 88 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 I 0 Appliances/other 2350 0 Subtotal (lines 6 to 13) 2197 4607 I 2933 2591 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 15 Redistribution Subtotal Duct loads I27% 12%l 41 2239 601 76 4683 98 27% 2% 163 3097 832 221 2812 59 Total mom load Air required (cfm) 2840 112 4782 210 I 3929 155 2871 126 �i Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" Right -Suite® Universal 2017 17.0.08 RSUD8101 I 2018-Mar-22 1 Pag AAfte 6 ...rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Cale = MJ8 Front Door faces: W 9 I . -i i wrightsoft° Right-JO Worksheet Entire House '' QUICK CALCS, INC. 317'I ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS@AOL.COM Job: Date: MARCH 22, 2018 By: 1' Room name LAUNDRY BEDROOM 2 2 Exposed wall 0 it 12.0 it 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 51 Room dimensions Room area 7.0 x 8.0 ft 56.0 ft2 13.0 x 120 it 156.0 ftz Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btutt/ft2) Area (ft� or perimeter (it) Load (Btuh) Area (119 or perimeter (ft) Load (Btuh) 11 Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6, 13AAocs 2 glazing, cir low-e 2 glazing, clr low-e 0.143 0.650 0.650 n n n 4.00 18.20 18.20 255 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 113 0 15 98 0 0 392 0 273 249 0 225 11 13A flocs 2 glazing, clr low-e 0.650 0.650 a a 4.20 18.20 255 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 oiazma, clr low-e 13AAocs 0.650 0.650 0.143 a e. s 18.20 18.20 4.00 33.77 33.77 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 1 '� 2 glazing, clr low-e -0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 13AAocs 0.143 w 4.00 255 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 jj� 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0- 0 0 IC 166-7ad 0.112 '3.14 5.88 56 56 176 .329 156 156 489 917 F l I' 22A-tpl 0.989 27.69 0.00 56 0 0 0 156 12 332 0 6 11c) AED excursion -18 -54 (Envelope loss/gain 176 311 I 1486 1337 12 a) Infiltration 0 0 190 51 I b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 1' Appliances/other 500 1000 Subtotal (lines 6 to 13) 176 811 1 1676 2388 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 9 234 186 14 ISubtotal 180 820 1910 2674 15 Duct loads 2i/o 2% 48 17 27% 2% 513 54 Total room load 229 837 2423 2628 Air required (cfm) 9 37 95 116 III -Fk wrightsoft" Right -Suite® Universal 2017 17.0.08 RSU08101 AGCA .rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Calc = MJ8 Front Door faces: W 2018-Mar-22 10:13:49 Page 7 O NN N x U Q 2 Aa) W Y Z 0 N � J p= a U � 0 Y t V rr W 0 FA OI N S O O O O O O O O O O O O O a0 0 N N O 0 0 O O O S N Cl)sn N $ U L�� NO gi00000000000005(8 SO NV OONg� (OCpp a 9 O N .-- r r t� f� N N to x x` H 0 X �cd E000000000000001W RI o c) a of � v, o � 'E w 00000000000000 0000000000000 � oLO y� S N N `o ' C7 W 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (8 0 v S m 0 00 CD o o m 0 0 O O 8 N w ry D B� 7 n O O O O O O O O O O O O O O�� � M O W O O W O O 00 0 N N CV N x = J X UCV CAOOOOOOOOOOOOOOCO N r o Cn n. m y v o E m00000000000000Com o cn m N ln�S �fc*��Ic.��cl+���SS OI �I�nMmS p CC�� SNNSNONS NNNSN N(A;ip- x� pp CO V W pD �aCl CO CDC O2 CD OW IT GO 00C CAN r r cV x • ®,� 0 O ccc may a�mw yN y33 33 � � �'�. 0000c000000000000 � � 7 U NN N O7N Nd CV CU N ygNN'9N�9N9N9U,9N9�9'�_9�_9 2 `a m B CEWV9N(0i(C(0f0990f�n �_ \q � p� y 9C �E �v E3L'E U'c rnrn aooTrna�oi�rna0��Q7 Si c Of c .N O 9 C �jL v N NN N NN CM CM N N NrrN p) r 000 N L" E 9EEE ¢ ¢ ¢a: E o to (a FT �C7IICI17CI17 �CI17CII�4II UU- o W m a 's CM � ¢vl0 Ida —NCO aLO m mm a rm to oa N ca 3 a 2 N w .O S Y �m w s2 w rn° W Q Y lL s° m 1 a -1= L v , co N N U a t0 t0 AW W L N Sit Z O y LL rn N U 1 1.0 ++ O Y c a GG W o LL lL U w O a - ir LL ch w _In m O O O O 00200 00 000000000000000n0 n 00 n 00n00 00 O id = 0 x O O O O O O O O O O O O O O O N O a R O C OOOOOOOOOOOOOOONN ` O 010 n000000000000 r'0 V �O O� OOu)T cV f0 C9 N 'C (rrff N C9 O �q N cD O f T 0o 0� x �OOOOOOOOOOOOOOt�T - - - m 0 v cA a ri v fo�pp D7 ..y voT000000000000c8$ o • T ,- ,, N 4 0 U � R 'N�rNc�+c�c�NvvTNv�'c�'Tvio �� CS pppN N p N pppp O a pppppppbVi 3,8 C0000•t CD OD OD st OD O7 OD t{OD 006Mcn�' . «CVVV l�L O ccc and mmrn NN w3333 " �'�. o0000000000000000 �� j U — �o Zoo o b= O to Bap E y — L E3rnEy E � Uc fO N N l9 N' f0 10 10 ag-55-agwirngrnmo i*C.4clj ..+ C NNN NNN NN- 8 ors Q E y y �~ O LU �s U) Imo �a 3 W 0 0 O LL co 7 m N co II 00 o m �U n 2 N w "o �x a +I+ wrightsoftx Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: OUICKCALCS@AOL.COM Job: Date: MARCH 22, 2018 By: 1 i Room name CLST 3 CLST 4 Exposed osed wall 2.0 ft 0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 7.0 x 2.0 ft 6.0 x 2.0 ft 5 Room area 14.0 ft2 12.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 VL213A-4ocs 0.143 n 4.00 2.55 19 19 75 48 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00 2.65 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 alazina. clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 255 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 1 2 glazing, clr low-e 0.650 s 118.20 14.99 0 0 0 0 0 0 0 0 4ocs 0.13 w .0 2.55 0 0 0 0 0 0 0 0 2 2 glazing, clr low-e glazing, 0.6550 w 188.220 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 11 D0 0.390. w 10.92 11.31 0 0 0 0 0 0 0 0 C- 11613-7ad 0.112 3.14 5.88 14 - 14 44 82 12 12 38 71 i i i I, i F 22A-tpl I 0.989 27.69 0.00 14 2 55 0 12 0 0 0 6 c) AEDexcursion -3 -2 Envelope loss/gain 175 127 38 69 12 a) Infiltration 32 8 I 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 206 136 3B 69 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -206 -136 -38 -69 14 Subtotal 0 0 0 0 15 Duct loads 1, 27% 21% 0 0 27% 2°/ 0 0 Total room load 0 0 1 0 0 Air required (cfm) 0 0 0 0 wrightsoft' A137KRight-Suite@ Universal 2017 17.0.08 RSU08101 ...rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Cato = MJ8 Front Door faces: W 2018-Mar-22 10:13:49 Page 10 +I+ wrightsoft, Right-JO Worksheet Entire House QUICK CALLS, INC. 317',ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: OUICKCALCS®AOL.COM Job: Date: MARCH 22, 2018 By: 1 Room name BEDROOM 4 BATH 3 2 Exposed wall 29.0 ft 20.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cod 4 Room dimensions 1.0 x 177.0 ft 10.0 x 10.0 ft 5 Room area 177.0 ftz 100.0 ftz Ty Construction U-value Or HTM Area (ftj Load Area (ftq Load number (BtUWftMF) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross WP/S Heat Cod 6 V►/ 13A-4ocs 0.143 n ' 4.00 2:55 132 132 527 335 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 vh 13A-4ocs 0.143 a 4.00 255 141 126 505 321 94 94 376 239 11 2 glazing, clr low-e 0.650 a 18.20 33.77 15 0 273 507 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 oiazmc. clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 vh13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 94 88 352 224 1 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 6 6 109 90 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 VVVVjjjj///l 13A-4ocs 0.143* 4.00 255 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 I, 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 11 DO 0.390 w- 10.92 11.31 0 0 - 0 0 0 0 0 0 C 16B-7ad 0.112 3.14 5.88 - 177 177 555 1041 100 100 314 588 i j� i r I F 22A-tol 0.989 27.69 0.00 177 29 803 0 100 20 554 0 6 c) AED excursion -17 1 -27 Envelope loss/gain 2663 21861 1705 1114 12 a) Infiltration 459 123 317 85 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 3122 2309 2022 1199 Less external load 0 01 0 0 Less transfer 0 01 0 0 Redistribution 435 520 263 352 14 Subtotal 3557 2828 2285 1551 15 Duct loads 271/. 21% 955 59 27/6 20/6 614 33 Total room load 4512 28MI 2899 1583 Air required (cfm) 178 1271 114 70 . A - wrightsofta Right -Suite® Universal 2017 17.0.08 ASU08101 ...rightsoft HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Calc = MJ8 Front Door faces: W 2018-Mar-22 10:13:49 Page 11 +I+ wrightsoftb Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: OUICKCALCS®AOL.COM Job: Date: MARCH 22, 2018 By: 1 Room name HALLWAY 2 Exposed wall 4.0 ft 3 Room height 9.4 ft heat/cool 4 5 Room dimensions Room area 1.0 x 52.0 it 52.0 ftz Ty Construction U-value Or HTM Area (ftq Load Area Load number (BtuWftz°F) (BtulVftz) or perimeter (11) (Btuh) or perimeter Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 Vu 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 1 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0.650 a 38 20 80 51 11 2 glazing, clr low-e 2 glazing, 0.650 a 8.20 18.20 3.55 33.77 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 2 clazin0. clr low-e 0.650 a 18.20 33.77 18 0 320 593 0.143 s 4.00 2.55 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 N13AAocs 2 glazing, clr low-e 0.650 s 18.20 - 14.99 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0.650 w 4.20 2.77 0 0 0 0 2 glazing, clr low-e 2 glazing, 0.650 w 18.20 33.77 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 11D0 0.390 w 10.92 11.31 0 0 0 0 C 1613-7ad 0.112 3.14 5.88 52 52 163 306 F 22A4pl 0.989 27.69 0.00 52 4 111 0 i I I ' I I 6 c) AED excursion 1911 Envelope loss/gain 674 .969 12 a) Infiltration 63 17 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Applianceslother 0 Subtotal (lines 6 to 13) 737 986 Less external load 0 0 Less transfer 0 0 Redistribution -737 .986 14 Subtotal 0 0 15 Duct loads 27% 2% 0 0 Total room load 0 0 Air required (cfm) 0 0 J 8th Ed. I wrightsoitw A & Right -Suite® Universal 2017 17.0.08 RSU08101 ...rightsolt HVAC\DEDRICK RESIDENCE- BKV HOMES.rup Calc = MJ8 Front Door faces: W 2018-Mar-22 10:13:49 Page 12 i +I+ wrightsoW Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: QUICKCALCS®AOL.COM For: DEDRICK RESIDENCE, BKV HOMES 2314ATLANTIC BEACH BLVD., FORT PIERCE, FL34949 Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1567 cfm Job: Date: MARCH 22, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 200 ft 11567 cfm Name Design (Btuh) Htg .(cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct _ Actual Matli Ln (ft) Ftg.Egv Ln (ft) Trunk 417H 2 h 969 38 26 1.000 5.0 Ox 0 VIFx 31.2 135.0 st3 BATH 3 h 2899 114 - 70 1.000 6.0 Ox 0 VIFx 45.2 155.0 st4 BEDROOM 2 c 2628 95 116 1.000 7.0 Ox0 VIFx 9.9 115.0 sti BEDROOM 3 C 2566 90 113 1.000 7.0 Ox0 VIFx 25.9 135.0 st3 ETD ROOM 4 h 4512 178 127 1.060 7.0 Ox0 VIFx' 39.2 155.0 st4 DEN C 2747 99 121 1.000 7.0 Ox0 VIFx 19.7 115.0 sti DINING ROOM c 3219 115 142 1.000 8.0 0x0 VIFx 35.6 115.0 st2 FAMILY ROOM h 3929 155 126 1.000 7.0 Ox0 VIFx 27.8 135.0 st3 FOYER c 2114 67 93 1.000 7.0 Ox0 VIFx 32.2 115.0 st2 KITCHEN C 2391 56 105 1.000 7.0 0x0 VIFx 31.7 135.0 st3 KITCHEN -A C 2391 56 105 1.000 7.0 Ox0 VIFx 11.0 115.0 sti LAUNDRY C 837 9 37 1.000 5.0 Ox0 VIFx 12.1 115.0 sti M WIC 1 h 654 26 15 1.000 4.0 0x0 VIFx 44.0 135.0 st5 M wIC 2 C 234 10 10 1.000 4.0 Ox 0 VIFx 44.0 135.0 st5 MASTER BATH h 5039 199 119 1.000 7.0 Ox0 VIFx 45.8 135.0 st5 MASTER BEDROOM h 2993 118 114 1.000 7.0 Ox 0 VIFx 33.1 115.0 st2 MASTER BEDROOM -A h 2993 118 114 1.000 7.0 Ox 0 'VIFx 37.4 115.0 st2 TOILET h 615 24 14 1:000 4.0 Ox0 VIFx 46.5 135.0 st5 Trunk Htg Clg Design Veloc Diam H x i W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk sty Peak AVF 258 159 1.000 739 8.0 0 x 0 VinlFix st2 st2 Peak AVF 676 621 1.000 861 12.0 0 x 0 VinlFlx st4 Peak AVF 292 197 1.000 836 8.0 0 x 0 VinlFlx st3 st3 Peak AVF 631 567 1.000 804 12.0 0 x 0 VinlFlx sti st1 Peak AVF 891 946 1.000 770 15.0 0 x 0 VinlFlx Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rtii Ox0 1567 1567 0 0 0 0 Ox 0 VIFx