HomeMy WebLinkAboutSEWAGE1
#:/�P1342272
Permitting pepaMnentAPPLICATION
STATE OF FLORIDA Lucie Count% PERMIT #: 56-SF-1843809
F ~'y DEPARTMENT OF HEALTH
St,
#:F11271869
ONSITE SEWAGE TREATMENT AND DISPOSAL
DOCUMENT
SYSTEM 08/03/2018
DATE PAID:
' CONSTRUCTION INSPECTIOE- APPROVAL
•��
MlayAW
FEE PAID:25.00
II
II
RECEIPT #:56-PID-3635269
APPLICANT:II Brookville Homes of PBC INC
Mauricio Salas
AGENT:
PROPERTY ADDRESS: 2314 Atlantic Beach Blvd Fort Pierce, FL 34949
LOT: 18 BLOCK: 30
SUBDIVISION: ID#: 1436-603-0029-000-2
I. CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
�I
TANK INSTALLATION
SETBACKS
[ ] [01]I TANK SIZE [1] 1090.00 [2) [
) [271 SURFACE WATER FT
[ ] [02]I TANK MATERIAL Polypropylene [
) [28] DITCHES FT
[ ] [03]' OUTLET DEVICE [
] [291 PRIVATE WELLS FT
[ ] [04]I1 MULTI —CHAMBERED [ L.!j N ] [
] [30] PUBLIC WELLS FT
[ ] [05]I' OUTLET FILTER Polylok PL-68 [
) [311 IRRIGATION WELLS FT
[ ] [06]I1 LEGEND 1. 70-143-11DC3 2, [
] [32] POTABLE WATER 38 FT
[ ] [07]., WATERTIGHT [
] [331 BUILDING FOUNDATIONS 6 FT
[ ] [08111 LEVEL [ •]
[34] PROPERTY LINES 13 FT
[ ] [09]I' DEPTH TO LID [
] [35] OTHER FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
I
[ ] [10]iAREA [1] 679.2 [21 SOFT [
] [361 DRAINFIELD COVER
[ ] [11] DISTRIBUTION BOX HEADER X [
) [37] SHOULDERS
[ ) [121INUMBER OF DRAINLINES 1. 8.00 2. [
) [381 SLOPES
[ ] [13]:', DRAINLINE SEPARATION [
) [39] STABILIZATION O$/12i2019
( ] [14]II DRAINLINE SLOPE
[ ] 1151 I DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [161 ELEVATION [ ABOVE / SELOW ]BM 7.00 [
] [401 UNOBSTRUCTED AREA
[ ] 1171 IISYSTEM LOCATION [
] [411 STORMWATER RUNOFF
I ] 11811,DOSING PUMPS [
] [421 ALARMS
[ ] 1191 jIAGGREGATE SIZE [
] [431 MAINTENANCE AGREEMENT
( ) [201 I�AGGREGATE EXCESSIVE FINES [
] [441 BUILDING AREA
[ ] [211 ;AGGREGATE DEPTH [
] [451 LOCATION CONFORMS WITH SITE PLAN
[
] [461 FINAL SITE GRADING
FILL I% EXCAVATION MATERIAL
[
] [47] CONTRACTOR MICHAEL W STUHR (ASHTO
[ ) [221 II FILL AMOUNT
[ ) 1231 li FILL TEXTURE [
] [48) OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [241 1IEXCAVATION DEPTH
ABANDONMENT
[ ] [251 IIAREA REPLACED [
] [491 TANK PUMPED
[ ] [261 1IREPLACEMENT MATERIAL [
] [501 TANK CRUSHED & FILLED
Comments: Comments are on page 2.
I I
I I
/ —��
Il
St. Lucie CHD DATE: 02/11/2019
CONSTRUCTION [ APPROVED
DISAPPROVED ) ° En ron ntal Speciaiist II Bri
I�
gram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED /
St. Lucie CHD DATE: 03/12/2019
DISAPPROVED ]:
gram (ENVIRONMENTAL HEALTH)
Environmental Specialist II dar'."used)
(Explanation of Violations on following page)
I
DH 4016, 08/09 (Obsoletes all previous editions which may not
Incorporated:I164E-6.003, FAC
Page 2 of 3
11 EH Database v 1.0.1 AP1342272
EID1843809
.I
I
I
STATE OF FLORIDA
c �y DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
WS
I,
Violation Number Comment
APPLICATION #:AP1342272
PERMIT #: 56-SF-1 843809
DOCUMENT #: FI1271869
DATE PAID:08/03/2018
FEE PAID:25.00 .
RECEIPT #:56-PID-3635269
The system is'I sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd. it
New ST, outlkfilter, and 4x7+4x8 long DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final
Inspection for mound system and final site grading.
Final system approved. Contractor and building department emailed final approval.
'i
I
I .
,
III
I
I
I'
III
'I
I
II
I
II
�I
III
I'
I'
I
DH 4016, 08109 (Obsoletes all previous editions which may not be used)
Incorporated: 64"E-6.003, FAC
EN Database v 1.0.1 AP1342272 EID1843809
Page 2 of 3
I�
'I
INSULATION CERTIFICATE
I�
PERMI I#
CONTRIPCTORS NAME
PROPERTY ADDRESS
CEILING INSULATION
MANUFACTURES NAME
INSULATION TYPE
R-VALUE INSULATION
INSULATION THICKNESS
LOCATION INSTALLED
DATE OF INSULATION
I
WALL INSULATION
I'
MANUFACTURES NAME
INSULATION TYPE
R-VALUE INSULATION
INSULATION THICKNESS
LOCATION INSTALLED
DATE OF INSULATION
SLC 1806-0597
BROOKVILLE HOMES OF PBC, INC
2314 ATLANTIC BEACH BLVD FT PIERCE FL
KRAFT KNAUF
BATT
R-30
9 1/2"
CEILINGS
11/22/2018
KRAFT
FI-FOIL
BAT
REFLECTIVE
R-13
4.1
3 1/2"
GARAGE
EXTERIOR WALLS
11/22/2018
11/22/2018
ATTIC INSULATION INSTALLED WITH VENTILATION PER FLORIDA RESIDENTIAL CODE 2017
i
INSULATION CONTRACTOR SIGNATURE
CGC 1509510