Loading...
HomeMy WebLinkAboutPRODUCT APPROVALj Product Approval dbon'ar XK USER; Public User � Product Approval Menu > Product or ADolication Search > Aoolication List > Application Detail FL # FL4525-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Metal Building Supplies, LLC Address/Phone/Email 800 E. Donegan Ave Kissimmee, FL 34744 (407) 935-9714 Flvalidation@yahoo.com Authorized Signature Scott Prossen Flvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Locke Bowden the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 05/01/2024 Validated By Zachary R. Priest, P.E. O Validation Checklist - Hardcopy Received Certificate of Independence FL4525 R4 COI FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.odf Referenced Standard and Year (of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvj CiiNa3lFkM... 6/25/2018 ,Florida, Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 09/19/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/18/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 4525.1 24 Ga. 1.0 Nail Strip 1.0 Nail Strip 24 Ga. 16" Wide Roof Panel over 15/32" APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-153.5psf Created by Independent Third Party: Yes Other: -59.75 psf. @ 16" o.c. fastener spacing. -101.0 psf @ Evaluation Reports 6 3/4" o.c. fastener spacing. -153.5 psf @ 6 3/4" o.c. FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.Pdf fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 4525.2 24 Ga. 1.5 Snap Lock 1.5 Snap Lock 24 Ga. Roof Panel over APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4525 R4 II FL 4525 Metal Building Suoolies 20f7 Metal Roofina FINAL-crss.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-116.Opsf Created by Independent Third Party: Yes Other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf Evaluation Reports @ 6" o.c. Install per manufacturer's details. For use in HVHZ FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.rdf Zones. Created by Independent Third Party: Yes 4525.3 26 Ga. 3/4" Ultra Rib 26 Ga. 3/4" Ultra Rib over APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes Other: -71.75 psf @ 24" o.c. fastener pattern.-159.25 psf Evaluation Reports @ 12" o.c. fastener pattern. Install per manufacturers FL4525 R4 AE FL 4525 Metal Building Suoolies 2017 Metal Roofing FINAL-crss.pdf installation details. For use in HVHZ Zones. Created by Independent Third Party: Yes 4525.4 26 Ga. 3/4" Ultra Rib 26 Ga. 3/4" Rib Roof Panel over 1x4 SYP Wood Purlins over APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-164.2psf Created by Independent Third Party: Yes Other:-106.75 psf @ 24" o.c.-164.25 psf @ 12" o.c. Install Evaluation Reports per manufacturers details. For use in HVHZ Zones. FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Created by Independent Third Party: Yes 4525.5 26 Ga. PBR 26 Ga. PBR Roof Panel over 1x4 SYP Wood Purlins over APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -100.5 psf @ 24" o.c.-151.75 psf @ 12" o.c. Install Evaluation Reports per manufacturers installation details. For use in HVHZ FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss,gdf Zones. Created by Independent Third Party: Yes 14525.6 126 Ga. PBR 126 Ga. PBR 36" Wide over APA Rated Plywood I Approved for use in HVHZ: Yes \ Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -60.5 psf @ 24" o.c.-154.75 psf @ 12" o.c. Install Installation Instructions FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525 R4 AE FL 4525 Metal Building Suoolies 2017 Metal https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvj CiiNa3lFkM... 6/25/2018 „Florida Building Code Online Page 3 of 3 per manufacturers installation details. For use in HVHZ Roofing FINAL-crss.pdf Zones. Created by Independent Third Party: Yes 4525.7 Min. 29 Ga. 3/4” Ultra Rib Min. 29 Ga. 3/4" Rib over 15/32" APA Plywood and 29 Ga. over 1x4 SYP wood purlins Limits of Use Installation Instructions Approved for use In HVHZ: No FL4525 R4 II FL 4525 Metal Buildinci Su lies 2017 Metal Roofing FINAL-crss.Dclf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-146.Opsf Created by Independent Third Party: Yes Other: Over Plywood-84.25 psf. @ 24" D.C. -146.0 psf @ 12" Evaluation Reports o.c. Over 1x4's-45psf@24"o.c,-175.5psf@12"o.c.-Install per FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes Contact Us :: 2601 Blair, Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M 10 :Check M Credit securitymirrRics' https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvj CliNa3lFkM... 6/25/2018 ,r Florida Building Code Online Page 1 of 3 , „rf YYl I a o,p�A9TNJtM pf� Business & � e`ssionaulat�on h n9 ���t� ;. ,.��"a`.`°���.k<. � � .� � nePR,Ifnva; PaoaroaPn oepteo�rlatoers colvr,,croepR Ora Product Approval USER: Public User Product Approval Menu > Product or Application Search > AoolicaUon Llst > Application Detail FL # FL4525-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived 171 Product Manufacturer Metal Building Supplies, LLC Address/Phone/Email 800 E. Donegan Ave Kissimmee, FL 34744 (407) 935-9714 Flvalidation@yahoo.com Authorized Signature Scott Prossen flvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Locke Bowden the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 05/01/2024 Validated By Zachary R. Priest, P.E. 95 Validation Checklist - Hardcopy Received Certificate of Independence FL4525 R4 COI FL 4525 Metal Building Supplies 2017 Metal Roofina FINAL-crss. odf Referenced Standard and Year (of Standard) Standard FM 4471 TAS 100 TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code FILE COPY Year 1992 1995 2003 2012 2006 https://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvj CiiNa3lFkM... 6/25/2018 Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 09/19/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/18/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 4525.1 24 Ga. 1.0 Nail Strip 1.0 Nail Strip 24 Ga. 16" Wide Roof Panel over 15/32" APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-153.Spsf Created by Independent Third Party: Yes Other: -59.75 psf. @ 16" o.c. fastener spacing. -101.0 psf @ Evaluation Reports 6 3/4" o.c. fastener spacing. -153.5 psf @ 6 3/4" o.c. FL4525 R4 AE FL 4525 Metal Building Suoolies 2017 Metal Roofing FINAL-crss.pdf fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 4525.2 24 Ga. 1.5 Snap Lock 1.5 Snap Lock 24 Ga. Roof Panel over APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4525 R4 II FL 4525 Metal Building Suoolies 2017 Metal Roofina FINAL-crss.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-116.Opsf Created by Independent Third Party: Yes Other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf Evaluation Reports @ 6" o.c. Install per manufacturer's details. For use in HVHZ FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.ndf Zones. Created by Independent Third Party: Yes 4525.3 26 Ga. 3/4" Ultra Rib 26 Ga. 3/4" Ultra Rib over APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes Other: -71.75 psf @ 24" o.c. fastener pattern.-159.25 psf Evaluation Reports @ 12" o.c. fastener pattern. Install per manufacturers FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf installation details. For use in HVHZ Zones. Created by Independent Third Parry: Yes 4525.4 26 Ga. 3/4" Ultra Rib 26 Ga. 3/4" Rib Roof Panel over Ix4 SYP Wood Purlins over APA Rated Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4525 R4 II FL 4525 Metal Building Supplles 2017 Metal Roofing FINAL-crss.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-164.2psf Created by Independent Third Party: Yes Other:-106.75 psf @ 24" o.c.-164.25 psf @ 12" o.c. Install Evaluation Reports per manufacturers details. For use in HVHZ Zones. FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Created by Independent Third Party: Yes 4525.5 126 Ga. PBR Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -100.5 psf @ 24" o.c.-151.75 psf @ 12" o.c. Install per manufacturers installation details. For use in HVHZ Zones. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -60.5 psf @ 24" o.c.-154.75 psf @ 12" o.c. Install 26 Ga. PBR Roof Panel over 1x4 SYP Wood Purlins over APA Rated Plywood Installation Instructions FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525 R4 AE FL 4525 Metal Building Suoolies 2017 Metal Roofing FINAL-crss.pdf Created by Independent Third Party: Yes 26 Ga. PBR 36" Wide over APA Rated Plywood Installation Instructions Verifed By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525 R4 AE FL 4525 Metal Building Suoolies 2017 Metal https://www. floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvj CiiNa3lFkM... 6/25/2018 Florida Building Code Online Page 3 of 3 per manufacturers installation details. For use in HVHZ Roofing FINAL-crss,Ddf Zones. Created by Independent Third Party: Yes 4525.7 Min. 29 Ga. 3/4" Ultra Rib Min. 29 Ga. 3/4" Rib over 15/32" APA Plywood and 29 Ga. over 1x4 SYP wood pVrlins Limits of Use Installation Instructions Approved for use in HVHZ: No FL4525 R4 II FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crsS.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-146.Opsf Created by Independent Third Party: Yes Other: Over Plywood-84.25 psf. @ 24" o.c. -146.0 psf @ 12" Evaluation Reports o.c. Over 1x4's-45psf@24"o.c,- 175. Spsf@ 12"o.c. -Install per FL4525 R4 AE FL 4525 Metal Building Supplies 2017 Metal Roofing FINAL-crss.pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.139S. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, Ilcensees.licensed under Chapter 4S5, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here_. Product Approval Accepts: eCz M Cr6dit Card Safe securltyll ETRICs- https: //www. floridabuilding. org/prlpr_app_dtl. aspx?param=wGEVXQwtDgvj CiiNa3lFkM... 6/25/2018 d� �irCiiF ��ant� - 0 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 June 28, 2018 RICHARD B CARTWRIGHT 736 NETTLES BLVD JENSEN BEACH, FL 34957 REVIEW COMMENTS FOR OWNER Page 1 of 1 RE: Building Permit Number 1806-0648 As of today's date your Contractor is being notified along?with yourself that the referenced buiding permit has some issues listed in the comments below. We have asked that these issues be dealt with as quickly as possible so that we are able to continue to process this permit in a timely manner. This information is being shared with you so you are aware of the status of your permit. PROPERTY INFORMATION 566 NETTLES BLVD JENSEN BEACH, FL 34957 APPLICATION INFORMATION Permit Number: 1806-0648 Permit Type: ROOF - METAL REVIEWS AND COMMENTS Review Tvpe Status PLANNING REVIEW PENDING CONTRACTOR INFORMATION Stories: 1 Reviewed Bx Date Started Date Completed JOSEPH FERSCH 6/28/2018 Date Released 6/28/2018 10:39:39 AM Comment: FOR ROOF OVER INSTALLATION. THE INSTALLATION MUST BE IN COMPLIANCE WITH 15C-2.0072 # (6) MOBILE/MANUFACTURED HOME INSTALLATION STANDARDS Thursday, June 28, 2018 10:45 AM