Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EVALUATION REPORT CONCRETE ROOF TILE
F)o \i TRINIIYIERD EVALUATION REPORT MN I fi GRA R 0 C), F T I L E: Entegra Roof Tile, LLC 1289 NE 9th Avenue Okeechobee, FL 34972 (602)515-6933 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report E39310.11.11-1-R4 FL7804-R10 Date of Issuance: 11/02/2011 Revision 4: 10/17/2017 SCOPE: , This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for fuse of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products; described herein have been evaluated for compliance with the®(E ition 2017� F on a Bui -ne Co e HVHZ sections noted herein. DESCRIPTION: Ente ra Concrete -Roof Tiles IHVH2 urisdict-ons LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. 11 INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: I i' Robert J.M. Nieminen, P.E. Florida Reglstratlon No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 10/17/2017. This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the prolduct. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. i TRINITY ( ERD ROOFING SYSTEM EVALUATION: 1. SICOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3. REFERENCES: Enti Examination Reference Date ERD (TST6049) TAS 101 P39740.02.12 02/21/2012 ATL (TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL (TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL (TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.05-15 11/07/2015 Miami -Dade (CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami -Dade (CER1592) HVHZ Compliance 15-0721.04 11/05/2015 Miami -Dade (CER1592) HVHZ Compliance 16-0112.06 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.07 02/25/2016 (Miami -Dade (CER1592) HVHZ Compliance 16-0112.08 02/25/2016 Tile Roof Institute TAS 100, TAS 101, 102, 102(A) Membership Confirmation Current iPRI (QUA9110) Quality Assurance Service Confirmation Exp. 11/02/2018 Exterior Research and Design, I.L.C. Evaluation Report E39330.11.11-1-R4 Certifi"a o/AuthorizaUon #9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 �.3 TAS 112, Type, Nail Holes I 17" Bella High "S" ng, IOW-p�Ofile), " { ESTATE"S" 811d HACIENDA Estate Hacienda ;.TAS 112, Type 2a (non-interlocking,_ high profile) Gi►LeNa SPANISH "S" arid REGAI Galena Spanish "S" I I Exterior Relisearch and Design, I.I.C. Certificate of Authorization 09503 I I I I I 10" 6T" EDITION (2017) FBC HVHZ EVALUATION Entegra Roof Tiles Regal Evaluation Report E39310.11.11-1-114 FL7804-R10 Revision 4:10/17/2017 Page 4 of 8 I �TRINI-rYJERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for i fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed the roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in I' accordance with TAS 112, Appendix W. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements, 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. I 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. i•' TABLE'1: AERODYNAMIC<MULTIPLIERS 0T3) Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Horizon, Fiat 0.305 0.330 Bella High "S" 0.349 0.378 Estate 0.267 0. 89 Hacienda 0.267 0.289 Galena Spanish "S" N/A 0.235 Regal 0.287 0.311 TABLE 2: RESTORING MOMENT DUE TO GRAVITY- Ma (FT-LBF), Tile Roof Slope (A 2:12<9<3:12 3:12<0<4:12 4:12<0<5:12 5:12<6<6:12 6:12<0<7:12 9>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Horizon 1 7.60 8.32 7.52 8.24 1 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High "S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.ao 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61 Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 Certificate iif Autharizatian #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 5 of 8 TTRINITYIERD TABLED: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF) MECHANICALLYATTACHED SYSTEMS Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Size Shank Clip Nail One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7A Nail One (1) 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 I Nail' Two (2)' 10d' Ring N/A 50.31 65.51 48.3' Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) #ii N/A N/A 51.7 51.7 24.4 'Installation with a 4-inch tile headlap and fasteners located min. 2Y2-inch from head oftile. Nail One (1)2 10d Smooth or Screw N/A 8.82 11.82 4.12 Nail Two (2) 10d Smooth or Screw N/A 16A 21.9 7.1 Nail One (1)2 10d Smooth or Screw Eave 19.01 19.02 22.12 Nail One(1)2 10d Smooth or Screw Field 24.32 24.3' 24.22 I. Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Estate "S"'or Hacienda Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Nail Two (2) 10d Ring N/A 27.8 37.4 28.8 Nail' Two (2)' 10d' Ring' N/A 43.0' 67.5' 50.91 Screw One (1) #8 N/A N/A 25.82 25.82 22.92 Screw wo 2 ® N A N A 47.1 47.1 49.1 'Installation with a 4-inch the headlap and fasteners located min. 2Y.-inch from head of tile. 2 For one (1) fastener installations, utilize hole that is approximately 4'/<-inch from the interlocking edge. Nail One (1) 10d Smooth or Screw N/A 5.1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One (1) 10d Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) lod Smooth or Screw Eave 29.3 29.3 24.0 Nail Two (2) 10d Smooth or Screw Field 27.6 27.6 38.6 Bella HighGalena r Spanish "S" oor Regal Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Nall Two (2) 10d Ring N/A 28.6 41.2 19.4 Nail' Two (2)1 10d' Ring' N/A 33.1' 48.11 50.9, Screw One (1) #8 N/A N/A 20.7 20.7 18.1 Screw Two (2) #8 N/A N/A 43.2 43.2 29.8 ' Installation with a 4-inch the headlap and fasteners located min. 2Y:-inch from head of tile. Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Certificate ojAuthorhadon #9503 6T" EDITION (2017) FBC HVH2 EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 6 of 8 i TRINITY I ERD TABLE 4: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF(FT-LBF) . MORTAR AND ADHESIV&SET SYSTEMS Note' from Entegra Roof Tile, `LLC: The performance data listed in'Table 4 are. based on the respective adhesive manufacturers"test reports and Miami=Dade: NOAs. Entegra Roof Tile,'LLC. relies upon the adhesive manufacturers to provide these values for our'inclusion in this FBC HVHZ' Evaluation, Report. Please: consult the individual 'adhesive manufacturer for information 'on product approvals, limitations, revisions or other information.for;determining wind load and overturning moment.performance. -. 11 Tile Adhesive Tile i Product Product Approval Placement Mf (ft-lbf) "TILE BONDTM" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat, "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Plantation Flat or Horizon "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 43 Independent medium paddy, 30 p ( p y g) 51 independent (large paddy, —45 g) 92 "TILE BOND" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 42 "S"'or "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate Hacienda "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 interdependent(2-paddy) 50 Independent (medium paddy, —30 g) 37 Independent (large paddy, —54 g) 61 Mortar Various Per RAS 120 21 "TILE BOND TM" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 48 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 52 Bella High "S", "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 Galena Spanish "S" or Regal "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent(2-paddy) 30 Independent (medium paddy, —30 g) 49 Independent (large paddy, —63 g) 94 Mortar Various Per RAS 120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or NTE RR Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S Galena Spanish "S" Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R4 Certificate ofAuthorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 7 of 8 QOTRINITYIERD H n rson Labeling: Horizon Flat, Hacienda, Regal 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Plant Profiles Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, I.I.C. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Cereificate ofAuthorizotion n9503 6'" EDITION (2017) FBC HVHz EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4:10/17/2017 Page 8 of 8 I I Southeast Building Engineers, 5911 Pescara Drive Pace, FL 32571 ' 772-774-9086 Ssa dens @m 7 lamas- buRdingeningeers.c-Qm FZECEIVED LL JUN 2 2 2M ST. Lucie County, Permitting Contractor: FCXARP kJAM'ROar�n/l, 'Ve. Date: 6r /SI/S Owner: S�tc K�z,va,enc Tile NOA: FL 760y.�-��o Job Address: �ju 9y C»ae.,00n Cr. PRr Si- Loci< Tile Roof B6RAc Esr.¢rE "S General Notes: New Roof _ Re -Roof X Recovering_ Repair Area 1. Entire roof deck to be renailed w/ 8dx2'/2' Ring§hank nails @ 6" o.c. through out TILE ROOF PLAN MM■M■M■■■■■■■■■ MM■M■N■M MM■MM■M MMM■M■MN M■M■M■M ■NR■■■■■ © �,MMMMMMM ° is ° ■aidN■MM■ MMMM■MM ■M■MMM■N MEMO■■■■ EMEMiii ° MEMMENEM ■■■■■■■ ■■■■■■■■ ■MOM■■■ °� ■■■■■■■ ■■■■■■■■ ° °° �■■■■■■■ M■M■ ■■■■ ° °°°° €� ° ° ° ° ® ■■MM■■■ ■■M■MM■M ■■■■■■■ ■■■■■■■■ ■■■■■■■■ N■■MMMM MMM■MM■M ■■MEMO■ ■M■MN ■■■■OMEN ■■■■■ --------••-•---.. -..,.may. .. .,.,ern �u�wucu uwy vNci Part2 Low Rise C&C Simplified Risk Cat 2/V = /do / Exposure B /A = /Kzt = 1.0/ Roof/Pitch= l /12 ht.= 41r' o " Zone 1 (Table R3Q1.2(2)) -2S 0 X Coefficient (Table R301.2(3)) 0 Zone 2 (Table R301.2(2)) -1lN, e X Coefficient (Table R301.2(3)) �. _ . yy, 0 Zone 3 (Table R301.2(2)) - LS, o X Coefficient (Table R301.2(3)) - c-6 , o Deck Type Thickness 's/sz'(M�cvl Other Tile Attachment: ; Mp = (P A)-M9= 0 x A 0.284 - M9 6 ,-5- = MP /2, 3 ¢Mr = y% Foam - NOA (Foam) Mortar -- Nail — Screw x _ Paddy Size Weight - Nail/Screw Size- ht8 # per the .(2 ) Ridge Vent DCSM Fastening Nail Ridge Tile Fastening: Mortar _ J Foam Underlav_ment attachment: a= 3(0`� a = 3-0�'-x Y=o'" Base Sheet 10tg.5ZIek _ U 13A t No. of Plies 1 Type of Fasteners/Bonding SrzF-,�j��di9Ri1Ki Ply Sheet - No. of•Plies - Type of Fasteners/Bonding - Fasteners/Bonding:, Nails ;0 �iae,rrh�.vK Self Adhering Roofing Nails & Tin Caps ue Fastener Spacing for Anchor/Base Sheet Attachment: &k JVAUd 3 cs ,d C. /N "SELYRCe FILE COPY Page 1 I 1 '// f