HomeMy WebLinkAboutCERTIFICATE OF TERMITE TREATMENTPERMIT #: /90�
Planning & Development Services SCANNED
Building & Code Regulation Division BY
2300 Virginia Ave St. Lucie County
Fort Pierce, FL 34982 tY
772-462-2172 Fax 772-462-6443
RTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
JOB ADDRESS: l�la'f�l 'unarm 47�+��l�i�vc-e
BUILDER/CONTRACTOR: K a
PEST 'CONTROL CONTRACTOR:
-A-BUG TERMITE & PEST CONTROL INC.
PEST�ICONTROL LICENSE #: JB175775
I
We, thle undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
I
Square feet if area treated: Chemicals used: DOMINION 2L
�I
Percentage of solution: .05% Total gallons used: . ' SCE
Date of Treatment: 9,hoks Time of Treatment: 1 .,G
11
Foo�tin�
V 1s� Treatment
Re -Treat
Driveway
f Treatment
Re -Treat
Other
r� Slab
1st Treatment
Re -Treat
Pools
1st Treatment
Re -Treat
Perimeter for Final Inspection
1st Treatment
Re -Treat
ignatur f Exterminator Date
Note; There must be acomp/eted form for each require treatment or re -treatment and this form must be on the job
site to!be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re inspection
fee charged.
FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment
Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval,
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014
SCANNED
BY
St. Lucie County
COLLNTY..
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave
Fort Pierce, FL 34982
772-462-2172 Fax 772-462-6443
RECEIVED
APR'. 0` S .7019
permitting DePartment
St,1_uae COUM
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
11
PERMIT #: 1806-0601 JOB ADDRESS: 14881 TUCAN FORT PIERCE, FL34951-4443
BUILDER/CONTRACTOR: WYNNE DEVELOPMENT
PEST CONTROL CONTRACTOR:
EVICT -A -BUG TERMITE & PEST CONTROL INC.
PEST CONTROL LICENSE #: JB175775
We, !the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: 210 LF
Percentage of solution:.05%
Date of Treatment:
03-16-2018
I; Footing
1st Treatment
Re -Treat
Driveway
1st Treatment
!! Re -Treat
Other
1st Treatment
Re -Treat
Chemicals used:. DOMINION 2L
Total gallons used: 125
Time of Treatment: 11:00
Slab
1st Treatment
Re -Treat
Pools
1st Treatment
Re -Treat
xxxxx Perimeter for Final Inspection
JR
PAUL C LUGARA JR Da'te: 018.1101141606-0400' A 04-05-19
Signature of Exterminator Date
Note: There must be a completed form for each required treatment or re -treatment and this form must be on the job
site l to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re -inspection
feeicharged.
FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistantjobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
proKiding a copy for the person the permit is issued to and another copy for the building permit files The Treatment
Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of
Protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval.
St Jl_ucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
7/24/2014
RECEIVED Professional Insulators of South Florida
APR 0 5 2019
FTC Insulation Installation Certificate
rmittin De 8 I To: St Lucie CountyDate: March 7, 2019
St. Lucie coq@"ate: Lot/Block:
Address: 14881 Tucan Project:
hoe harm inetallad in the, ahnva dacrrihM nrnnerty ac fnllnws:
1. Exterior CBS walls have been insulated with:
Spray -on Cellulose
Thickness in inches:
Fiberglass Blankets
Manufacturer:
Fi Foil
Rock Wool Blankets
Density:
X
Aluminum Foil
R-Value:
R 4.1
Rigid Board
H
Polystyrene
I
Other
2. Ceilings (level) have been insulated with:
Spray -on Cellulose
Thickness in inches:
11.1"
X
Fiberglass Blown
Manufacturer:
Climatepro
Rock Wool Blankets
Density:
Aluminum Foil
R Value:
R-30
Polyurethane
Open Cell SPF
Ceilings (Inaccessible) insulated with:
Spray -on Cellulose
Thickness in inches:
9.5"
X
Fiberglass Blankets
Manufacturer:
Johns Manville
Ignition Barrier
Density:
Fiberglass Blown
R-Value:
R-30
Cellulose Loose Fill
Open Cell SPF
3. Interior kneewalls have been insulated with:
Fiberglass Blankets
Thickness in inches:
Fiberglass Loose kill
Manufacturer:
Rock Wool
Density:
Fiberglass Blown
R Value:
Cellulose Loose Fill
Open Cell SPF
4. Garage partition walls of A/C living area have
X
Fiberglass Blankets
been insulated with:
Rock Wool
Thickness in inches:
3.59'
Polyurethane
Manufacturer:
Johns Manville
Spray -on Cellulose
Density:
Open Cell SPF
R-Value:
R-11
5. The following have been insulated:
••tea •••• '- ®�. -_
+•Z:ZpOB/lrF p® Z
=� SEAL =:_
2003
�.•; ; �:
�'�•�.+is;0;.� ��
WYNNIE BUILDING CORP.
General Contract/Builder
CBC1254041-p.
Competency #
Professional Insulators of South Florida, Inc.
Insulation Contractor
By: A�AW By:
1,