HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED FORM R405-2017 BY FLORIDA ENERGY EFFIb CY CODE FOR BUILDING CONSTRUCTION Florida. Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: " THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State,iZip: FT. PIERCE, F ,. Permit Number: Owner: \'--kcek \ \, "� Lei C� Jurisdiction: Design Location: FL, Fort Pierce I! County:: St. Lucie (Florida Climate Zone 2 ) I 1. New cons it I ruction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ftZ 1! b. Frame - Wood, Adjacent R=11.0 208.00 ftZ 3. Number of units, if multiple family 1 11 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftZ 10. Ceiling Types (1753.0 sqft.) Insulation Area 5. Is this a w, rt case? Yes a. Under Attic (Vented) R=30.0 1753.00 ftz 6. Conditionid floor area above grade (ftZ) 1753 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. R= ftZ 11. Ducts R ftZ 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor: Sgl, U=0.63 111.36 ftZ SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftZ SHGC; 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ftZ b. Conservation features b. N/A �' R= ftZ None c. N/A R= ftZ 15. Credits Pstat u Total Proposed Modified Loads: 53.83 Glass/Floor Area: 0.086 PASS Total Baseline Loads: 53.85 I hereby certify that the plans and specifications covered by Review of the plans and ST'q?� this calculation are in compliance with the Florida Energy specifications covered by this 0jq%E y _ 0,4, Code. calculation indicates compliance with the Florida Energy Code.buib PREPAR •D BY: DATE: -� Before construction is completed this building will be inspected for ii compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. �''0 WS OWNER/AG OE- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelopes leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11 4/16/2018 8:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 I i I -FORM R405 ,2017 PROJECT Title: II WYNNE THE WINDSOR IM Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: I, 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Numberli Name Area Volume ;I 1 Entire House 1753 14024 I; SPACES Number,, Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 !, MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 II WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS i # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet II 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 -___ 0 1 0 I' 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 _--_ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 0 1 0 II 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ____ 0 1 0 4/16/2018 8:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R40572017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6SIab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 _-__ 0 1 0 li 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 _--- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 _--_ 0 1 0 9-Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 _-__ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ___- 0 1 0 i 1,1Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0 I Slab -On -Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ____ 0 1 0 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1, Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC �1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood ,3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 14 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 15 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 118 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 19 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood ,10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood '11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) I BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Cavity Width Space Height Sheathing Framing Solar Below 0 1 NE=>W Exterior Concrete Block - Ext InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 2 S,W=>E Exterior Concrete Block - Ext IndMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 _ 3 NVV=>S Exterior Concrete Block - Ext InsMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 4/16/2018 8:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 .:nann Rd0r,L7n97 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w nrnt To Space Wall T�gpe5 NE=1>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE,,,>W Exterior Concrete Block - Ext IndRffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 _ 7 SW >E Exterior Concrete Block - Ext InQJNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block - Ext InEENNING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 _ 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE;>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 13 NE=>W Exterior Concrete Block - Ext InQEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 _ 14 SW=>E Exterior Concrete Block - Ext InQffDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 _ 15 N=I>SW �I Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 11 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 21i NE=>W i 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 : SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5;, NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None 611 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 1 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ;11 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholel ouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 4/16/2018 8:46 PM EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 HEATING SYSTEM #' System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM #' System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None i� ftZ DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 225 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Heatin Feb Mar Jan Feb EX� Mar A r E Apr f Jul May 4 Jun Jul Ma X Jun ri AuSep ri Aug Se rl Oct Oct Nov Nov HX Dec Dec H Venting Jan Feb [X Mar [x] A r [ Ma [ Jun Jul Aug Se [x] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/16/2018 8:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 I, 1. 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce I, COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General II A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. !i Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls I' The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. I� Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and ii continuous alignment with the air barrier. Windows; skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation I; a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on li installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building I' shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipmng and w6ring. Shower/fub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall I, be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cemlongs- a. ui auwuun, uisNCcuon of iog walls span oe in accoraance with the provisions or IGG-4uu. 4/16/2018 8:46 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I Ij FORM R405-2017 I! ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. I! 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.63 SHGC SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.21 c. U-Factor: N/A SHGC d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: THE WINDSOR, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1753.00 ft2 1753 b. N/A R= ft2 Area c. N/A R= ft2 111.36 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 225 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 2.850 ft. 0.239 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 . 1753.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Hot water systems Cap: 40 gallons a. Electric EF: 0.97 b. Conservation features None 15. Credits Pstat I certify than this home has complied with the Florida Energy Efficiency Code for Building ot ZgE Sx Construction through the above energy saving features which will be installed (or exceeded) A24P in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. rn1,- i ;;:•. �o Builder Signature: Date: Address of INew Home: -\ �1 City/FL Zi * �* WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsu'pport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1, 4/16/2018 8:46 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 i Project Summary Job: -- wrightsoft Date: Entire House By: QUICK CALLS, INC. �i • 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466.6799 Fax 772-466-6796. Email: QUICKCALCS@A0L.CW Project Information For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Weather: Fort Pierce, FL, US i Winter Design Conditions Outside db Inside db. Design TD Heating Summary Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area (ft2) Heating 1753 Cooling 1753 Volume (ft3) 14741 14741 AlP changeslhour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25H SC536A*030 AHRI ref 7914585 11 Efficiency 8.5 HSPF Heating.input Heating output 34600 Btuh @ 47°F Temperature rise 27 OF Actual air flow 1160 cfm . Air flow factor 0.047 -cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point = 34 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling Equipment. -Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swing multiplier Equipment sensible load 0.95 25645 Btuh Latent Cooling Equipment=Load Sizing Structure 2453 Btuh Ducts 2554. Btuh Central vent (0 cfm) 0 Btuh . (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800. Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure '0.50 in H2O Load sensible heat ratio 0.84 li Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c wrightsoft" 2017-Apr-1017:19:28 it Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 :.k Calcs(Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrightsoft- Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 F)gxised wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Rodm dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ftz 280.0 ftz Ty Construction U-value Or HTM Area (ft-) Loa d Area (ftz) Load number (Btuh/ftk-°F) (Btuh/ftz or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 i 13A4ocs 0143 ne -4.00 2-55 488 448 1795. 1141 192 192 769 489 1A-clom . 1 270 .ne 35:56 70:43 7 0 247 . 488 0 '" 0 , ;0 ' 0' INclom..: 1 270 :ne 35.56 70.0 16 :. 0 '. 581 .: •1151 0 '. 0 0 0 1Ao1om 1.270 • .ne. 35.56 45:24 16 0 ; 58t 739 .: 0: 0 " 0 0 11 D 13A-4ocs 0.143 se 4.00 2.55 , 64 41 165 105 0 0 : 0 .. 0 11D0 0.390 se 10.92 11.31 23 23 248 257 0 0 0 0 13A;4ocs 0143 sw-. 4:00 2;55 , ; - 437 396 1584 1007 56 :.56 ; 224 143. AA5.20m • 0.770 ' sw 21:56 . 27:53 41 45 893 1140 _. 0 0'. . `'. 0.. • - 0 13A-4ocs 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 202 1Aclom 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P y ; :=12C-0sw 0:091 . = . 2 55 1 28 308, - 808 = 784_ . : 395 - -0 ':. "'0 : .. 0 ' •:,0 C 16A-30md 0.032 - _ 0.90 52 1753 1753 1571 4067 280 280 251 650 22A,tpl" : :.. .: -' • 0.989 ' _ . 27.69 " 0.00 " 1753 '. . 153 4237 : " ' • 0 280 :. .. 45 1246 `.• 0 6 c)AED excursion 1360 .600 Envelope loss/gain 15594 15385 39701 3561 12 'i a) Infiltration 2873 810 809 228 b) , Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 p Subtotal (lines 6 to 13) 18467 17655 4779 3789 Less a denial load 0 0 0 0 Les's transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 18467 17655 4779 3789 34% 53% 6190 9340 340/6 53% 1602 2005 Total room load 24657 26995 1 1 6380 5794 Air required (cfm) 1160 1160 .3001 249 Of wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 A :..k CaIcslDocume iilWYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: 2017-Apr-10 17:19:28 Page 1 -- wr ightsoft° Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST..LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM Job: Date: By: 1 2 3 4 5 Room name • Rted wall Room height Room dimensions Room area WIC 0 ft 8.0 ft heaticool 7.0 x 9.0 ft 63.0 ft2 M. BATH 7.0 ft 8.0 ft heat/cool 1.0 x 61.0 It 61.0 ft2 Ty I, Construction U-value Or HTM Area (ft) Load Area t2) Load number (Btuh/ftZ-°F) (Btuh/112) or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 ; .13A4ocs 0.143 -.no -4.00 2.55 0 0 0 0 49 :196 125 1A-clom 1Ac1om ; 1.270 .:1.270 no, ne; 35.56 3556 70:43 70A3 0 : ' 0 W 0 0 ... 0 0 0 .56 7 ,. 0 0. 247, 488 11 1A�1om .`. 13AAocs -1.270 0.143 - na se 35.56 4.00 4524 2.55 0 0 :. 0 0 :" 0 0 0 0 0' 0 0.. 0 `U, 0 0 0 W ' 1100 13A-4ocs - 13A-4ocs 1Ac1om 0.390 0;143 0.143 1.270 se sw' sw: nw nw 10,92. 4.00 21:56 4.00 35.56 11.31 2 56 27.53 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 :` . , 0 0 0 0 0 0 0 0 0 0 ".0 . ::0 0 0 0 , ` 0 0 0 0 0 : : 6 Q 0 0 0 0 , 0 0 0 D y/ }r �1 I-G L-G P C I F . I�. 4A5-2omd ucC oiw 16A 30md 22/ktpl: 0.770 0.061 0.032 0989 - nw . <- ' _ 21.66 2;55. 0.90 "27c69 36.90 _: 1:28 2.32 0:00 0 : 0 63 63 0 0 63 . 0 0 ' ' 0.. 56 "' 0 0 0 146 : 0 0 ,0 61 ; : '`:61 0 ., 0 •61 . 7 0 0' 55 194 0 •,0 142 , 0 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) ''Infiltration b) ',Room ventilation I 0 0 0 0 126 0 35 0 13 Internal gains: Occupants @ 230 j Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 56 141 817 764 14 151 Loss) external load Less transfer Redistribution Subtotal Duct loads 34% 53% 0 0 0 56 19 0 0 0 141 75 34% 530/c U 0 0 817 274 0 0 0 764 404 I I' Total room load Air required (cfm) 75 4 216 9 1091 511 1168 50 - Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .A -I� wrightsofft' 2017-Apr-10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..i k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJB Front Door faces: N wroghtsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUDRY BEDROOM 2 2 - Bq)6sed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0' ft 5 Room area 36.0 ft2 180.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area t2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WKS Heat Cool 6 13AAocs 0.143 ne 4.00 2.55 0 0 0 0 •. 96 80 .'319 203 1Arc1om ;" . ` 1.270 ne. 35:56 ' . 70:43 '- 0 0 0 0 ' 0 : : 0 :: ' 0 0 1Ac1om 1.270 rie' 35.56 .70.43 .0 0 .0 0 16 0 5Blq 1151 AAc1om _ .1:270 ne -35.56 . 45.24 0 , 0 0. 0 0 0.. 0 0 V)1 ,. 11 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 D 11D0 „ 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A17ocs .. 0.143 <sw -4.00 2.55 0 0 0 0 0. W. 0 0 0.770 ••sw 21.56 .27.53 0 ' 0 0 0 0 .0 0 0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd- 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P ;12C-0sw 0.091 .- 2.55 1:28 ': 0 .0 0 0 0 ' ` 0 . 0 : :0 C 16A-30md 0.032 0.90 2.32 36 36 32 84 180 180 161 418 rF IM'tpl :. 0:989 = : 27.69 ' 0,00 36 0. 0' •'0 • .... 180. :: - 12 -: 332 ` ' .. .:.0 6 c)AED excursion -3 -60 Envelope loss/gain 32 811 1394 1711 12 a) Infiltration 0 0 216 61 b) i Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Lessextemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct; loads 34% 53% 13 50 34% 53% 541 945 ITTotal room load 51 145 2156 2730 Air required (cfm) 21 6 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .4 C- wrightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 k ...k CaIcslDacumentslWYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N Page 3 - - wrightsoft, Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Roam name DINING/GREAT ROOM KITCHEN 2 E-posed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 0.143 ne 4t00 2.55 0 0 0 0 0 0 0 0' 1Ac1om ' 1:270 ne 35i56 Z0.43 0, 0 0 0 0 0, 0 0 1Aclom 1.270 ,ne 35.56 70.43: 0 .0 0. .'0 0- 0 0 A 1A-c1om< 1:270 . ne,. 35.56 49.24 0 0 0- 0 0 0 '0 p 11 VP 13A4ocs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 L-D 11DO . 0.390 . se 10.92 11.31 0 0 0 0 0 0 0 0 4:00 2:55 267 .. ; ..226 .. : 903 : - :574 98 08.. -392 -249 -' 0:770 - sw 21.56 . '27.53 41 . 22 893 , 1140 - . 0 , 0 0 : ' 0. 13A-4ocs ' 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 G 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 :12C-0sw 0.091 ..- 2.55 T28 0 0 " 0 0 = • 116. ' -.116 296 W C 16A 30md 0.032 - 0.90 2.32 588 588 527 1364 209 209 187 485 F h 0:989 - 27.69 0.00 588 50 1385 : 0 209 11 305'---0 r 6 c)AED ecursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 220 62 b) ;I Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 .' Appliances/other 0 1000 Subtotal pines 6 to 13) 6136 6679 1399 . 1880 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 340/6 53%1 4691 995 Total room load 8200 10234 1867 2875 Air required (cfm) 3861 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ...k CaIcslDocuments\WYNNE-THE WINDSOR-REVISED.rup .Galt =MJB Front Door faces: N Page 4 wrphtsof#°. Right-JO Worksheet Date: �� Entire House ate: By. QUICK CALCS, INC. I' 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL,COM 1 Room name BATH HALL 2 Rted wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ftz 25.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft2L°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 1 6 13AAocs- 0.143 -ne ..4.00'. 2.55 40 40 160 102 0 0 0 .. 0 9A-c1om - 1.270 ne 35.56 70.43 0 0. 0 0 0- 0 0 0 1A-c1om . 1.270 nea- 35 56 70.43, • . ' .0 0 0 . ; : 0 0 %0 . 0 1Ac1om • 1k270 ne: . 35 56 4524 0 0 0 0 .: 0 0 11 V�1 ; 13A-4ocs 0.143 se. 4.00 2.55 0 0 0 0 0 0 0 0 I-D 11DO 0,390 se 10.92 11.31 0 0 0 0 0 0. 0 0 1/�l 13A0.143 �O.TJo sw. 4 00 255 0 p 0 . p p ' ' p ; 0 0 L ;^ '4A5.2om . : sw 21t56 2Z.53 p 0 0 0 0 0 0 13AAocs 0.143 nw 4.00 2.55 0 _ 0 0 .: 0 0 : 0 0 0 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd ,. 0.770 nw 21.56. 36.90 0 0, 0 0 0 0. 0, 0 . 12C-0sw. • .6091 .' = 2:55 '. 1:28 .' 0 p 0 0 . p . , 0 .. p .... 0. C 16A30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 F + 22A tpl.. 0.'989 • - 27 69 : 0.00 ' 50 5 138 ': ' 0 25- ' 0W. Tt { r ... 6 c)AED emursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other p 0 Subtotal (lines 6 to 13) 433 235 22 56 Less witemal load 0 ' 0 0 0 Lessl transfer 0 0 0 0 14 Redistribution Subtotal 6 14 -22 -56 439 249 0 0 15 Duct loads 1 34% 53% 1471. 132 34% 53% 0 0 Totalsroom load 586 381 0 0 Air required (cfm) 28 16 ol 0 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. C wrightsoft- 2017-Apr-10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N I I li wrightsoft RightJ® Worksheet°b Entire House Date: i� QUICK CALCS, INC. By. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-166-6796 Email: QUICKCALCS@,\OL.COM 1 Room name FOYER BEDROOM 3 2 Exposed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heaUcool 8.0 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 13.0 x 13.0 ft 5 Room area 92.0 ft2 169.0 ft2 Ty Construction U-value 'Or HTM Area (ft2) Load Area (ft2) Load h number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool l 6 ; ,13A4,- 0.143 ` ne A.00 . 2.55 0 0 0 0 104 88 351 223 1Ac1om 1:270 ne 35c5ti 70.43 0". 0 D 0 0" 0. 0 0 1Ac16m ;. 1e270 ne. 35:56 70.43 • 0 0 0 0 0 ; 0 ; 0 1Ac1om : ' 1.270 ne'. 35:5ti 4524 `. 0 0 0 0 16 0; 581, , 739 V�! li ' 11 13A-4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11DO 0.390..se 10.92 11.31 23 23 248 257 0 0 0 0 „D vu r ' C� 13A4ocs ; 0,148 sw- 4.00 2-55 • 8 8 ,' '. = 32.. "'... 20 8 8 - - `32 .20: .4Ar2om - A770 .aw.' 21:56 . 27:53 0 . . " .0 0 0 -. • ' 0. •- 0 0: 0 l i 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56. 36.90 0 0 0 0 0 0 0 0 P I} .' =:12C-0sw: 0091 .":-'.. '2.55 . 1023 88 t)8 : 224 113 `. 104 104 ':" '.;' . 265 . =:.133 C 16A-30md 0.032 0.90 Z32 92 92 82 213 169 169 151 392 0:989 .. _-: •; .:. 27.69 >. .'`0:00 r - 92 9 : 249 ".: '0 :..' . ,; 169 ' 14 '388 :: 0. 6 c)HED excursion -25 -52 E41ope loss/gain 1002 684 . 1768 1456 12 a)II Infiltration 162 46 252 71 b)j; Room ventilation 0 0 0 0 13 Intel mal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 . 1527 i� Less extemal"load 0 0 0 Less transfer 0 0 .0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 DuCtloads 34% 53% 390 3860 34% 53% 677 808 Total room load 1553 1116 2697 2335 Aih'required (ofm) 73 46 127 100 ACCA to tj�- wcigt�t§oft' Right -Suite® Universal 2017 17.0.14 RSU08101 �?I ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8. Front Door faces: N J 8th Ed. 2017-Apr-10 17:19:28 Page 6 -1- wlirightsofta Duct System Summary Da Job: House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Project• • For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External, static pressure Pressurelosses Available static pressure Supply %,I return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) . Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx .19.5 115.6 st1 BEDROOM C 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM h 2697 127 100 0.353 6.0 Ox0 VIFx 26.8 115.0 SO DINING/GREAT ROOM c 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/.GREATROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DINING/.GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox 0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 Ox0 VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 Ox0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox 0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 Ox 0 VIFx 36.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 ,i Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx �Wrl htsoft° 9 Right -Suite® 2017-Apr-1017:19:29 Universal 2017 17.0.14 RSU08101 Page 1 ... k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N Name Grille Size (in) Htg (cfm) Clg (cfm) . TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl* Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1017:19:29 ��. 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 2 .k CalcsWocuments%WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N �I