® SCANNED `h BY St. Lucie County MiTek < Lumber designv"s are in accordance with ANSI/TPI 1 section 6.3 These truss de,signs rely on lumber values established by others. RE: M11392 - THE WINDSOR MiTek USA Inc. Site Information: 6904 Parke East Blvd. Tama L 33 0 4115 Customer Info: Wynne Dev Corp Project Name: M1'1392 Model: 71 Carlton 3 Bedroor>�i ear orch Lot/Blobk: Subdivision: Address: unknown City: St.l Lucie County State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: I. License #: Address: City: , State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. I Seal# I Truss Name I Date 1 1 T113569660 1 A 3/22/18 1 2 1 T13569661 I Al 1 3/22/18 13 1 T13569662 1 A2 1 3/22/18 14 1 T13569663 1 A3 1 3/22/18 J 15 I T13569664 I A4 1 3/22/18 16 ( T13569665 1 A5 3/22/18 17 1 T13569666 1 ATA 3/22/18 1 18 1 T13569667 1 B 1 3/22/18 1 19 1 T13569668 1 BHA 1 3/22/18 1 110 1 T13569669 1 GRA 1 3/22/18 1 Ill I T13569670 I J1 1 3/22/18 1 12 I T13569671 I J3 1 3/22/18 1 13 I T13569672 I J5 1 3/22/18 L14 _ I T13569673 I J7 1 3/22/18 115_ _f T13569674 1 KJ7 1 3/22/18 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Finn, Walter My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs cpmply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. %011111111NI.. �P�'� ER P e`e C EIV S�•�� o 22839 • STATE OF .•�U� . i';ss0N A1r,EC? �e 1111111 Walter P. Finn PE No22839 MITek,USA, Inc. FL Cert 6634 69D4 Parke EaSCBlvd. Tampa FL 33610 Date: March 22,2018 Finn, Walter 1 of 1 Job Truss Truss Type city Ply THE WINDSOR T13569660 M11392 II A HIP I , 1 1 Job Reference (optional) n nn.a nn10 o—A cnamoers i russ, inc., ruu nei UU, r� T1-0-q it 6-10-14 9.0-0 , 10-0 jl 6-10-14 2-1-2 IIIII I I 4x8 = 4.00 12 4 6 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-jR3gUsZbktWXUduXL4V56b8 13 26.0-0 28-1-2 354 13 5-9-3 2-1-2 6-10 Scale=1:60.5 2x3 11 3x6 = 4x4 = 4x8 = 2x3 26 5 6 7 27 8 9 1b I 3x4 _ 3x4 = 3x6 _ 6x8 = 3x4 = 3x6 _ 3x4 = 3x5 LOADING (psf)' SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.01 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.42 12-23 >572 240 MT20 244/190 TCDL 7.0' Lumber DOL 1.25 BC 0.47 Vert(CT) 0.37 12-23 >659 180 BCLL 0.01 ' Rep Stress Incr YES WB 0.94 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight:161 lb FT=20% LUMBER- BRACING - TOP CHORD 12x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-5-1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=433/0-8-0, 15=1596/0-8-0, 10=669/0-8-0 ,Max Horz 2= 97(LC 10) Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10= 799(LC 12) Max Grav 2=467(LC 17), 15=1596(LC 1), 10=685(LC 22) FORCES. (lb),- Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-639/108, 3-4= 396/0, 4-5=-967/776, 5-7= 967/776, 7-8=-454/938, 8-9=-1009/1884, 9-10= 1265/2154 BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-1586/938, 10-12=-1971/1174 WEBS 3-17= 372/461, 4-17=-272/451, 4-15=-1087/1002, 5-15=-336/386, 7-14=-766/399, 8-14=-580/997, 8-12=-958/447, 9-12= 358/600, 7-15=-1329/2190 NOTES- 1) Unbalancedl roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. 11; Exp C; Eiicl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss figs been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=235, 15=1439, 10=799. Walter P. Finn PE No.22839 MiTek USA, Inc. Fl. Cart 6634 6904 Parke East Blvd. Tampa Fl. 33610 Date: March 22,2018 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll•7473 rev, 10/0312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual Truss web and/or chord members only. Additional temporary and permanent bracing : p� W prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the YYH� iy fabrication, storage, delivery, erection and bracing of trusses and Truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply T13569661 M11392 Al SPECIAL , 1 1 �THEWINDSOR Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:13.06 2018 Page 1 I D:_kfiGCA6bx7j2Sy 1 HDXFw7ye3KX-BdcDiCaDVBeO6nTjvol KfpgX? NVK4xW ep?Q56?zYQiB 1-0• 8-6-0 11.0-0 14-9-0 19-8-14 24.0-0 27-4-7 35-0-0 6-0- 0- 8-6-0 2-6-0 3-9-0 4-11-14 4-3-2 3-4-7 7-7-9 0-0 Scale = 1:61.3 5x6 = 2x3 11 5x6 = 3x4 = 4.00 FIT 4 21 5 6 22 7 13 12 3x6 = 3x5 = 5x8 MTi 8HS = 2.00 12 3x12 = Plate Offsets (X'Y)-- f2:0-0-2 Edgel f9:0-1-15 Edgel LOADING (psf)' SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) 0.75 11-12 >563 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -1.21 11-12 >348 180 MT18HS 244/190 BCLL 0.0, ` Rep Stress Incr YES WB 0.77 Horz(CT) 0.35 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 155 lb FT = 20% LUMBER- BRACING - TOP CHORD 12x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS �2x4 SP No.3 REACTIONS. (Ib/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Horz 2=-117(LC 10) Max Uplift 2= 825(LC 12), 9=-825(LC 12) FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1 2-3— 3209/2102, 3-4=-3006/2024, 4-5=-3022/2080, 5-6=-3022/2080, 6-7=-4643/2994, 7-8=-5324/3364,8-9=-5751/3700 BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478 WEBS 3-13=-425/410, 4-13=-354/571, 4-12=-362/617, 5-12= 269/279, 6-12— 1034/712, 6-11=-373/892, 7-11=-897/1523, 8-11= 404/435 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511t; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss 'has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSIfFPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=825, 9=825. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 Q WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �' a truss system. Before use, the building designer must vedty the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing : p,�A ��° Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 9tl�T i fabricatiort storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply THE WINDSOR T13569662 M1{392 A2 SPECIAL 1 1 Job Reference (optional) Lnamoers Truss, nnc., r-ort tierce, r-L 6 8-6-0 Sx6 = 3x4 = 4.00 12 4 21 5 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-fpAbvYbrGUmFjx2vTVYZBODhBnrxpNMn2f9ef 22.0-0 , 27-4-7 1 35.0.0 $6-0 7-3-0 Sx8 = 22 6 7-7-9 Scale = 1:61.3 " 12 3x4 = 5x8 = 3x12 = 3x6 = 2.00 F12 10-0-0 14-9-0 22-0-0 24-6-8 35-0-0 10-0-0 4-,-0 7-3-0 2-6-8 10-5-8 Plate Offsets (XY)-- f2:0-0-6 Edgel (6:0-4-0 0-2-31 (8:0-1-15,Edge1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) 0.72 10 >585 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.94 10-19 >447 180 MT18HS 244/190 BCLL 0.0. ' Rep Stress Incr YES WB 0.86 Horz(CT) 0.34 8 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 160lb FT=20% LUMBER- BRACING - TOP CHORD l2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS l?x4 SP No.3 REACTIONS. 11(lb/size) 2=1349/0-8-0, 8=1349/0-8-0 Max Horz 2=136(LC 11) Max Uplift 2= 825(LC 12), 8=-825(LC 12) FORCES. (lb)'- Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3211/2064, 3-4= 3017/1998, 4-5=-2580/1800, 5-6=-3379/2225, 6-7=-5242/3250, 7-8= 5759/3665 BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11= 1990/3441, 8-10=-3410/5485 WEBS 3-13= 420/418, 4-13=-427/688, 4-12= 337/551, 5-12=-777/605, 5-11=-465/925, 6-11= 391/277, 6-10— 1318/2268, 7-10=-503/530 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=7011; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Qt=lb) 2=825, 8=825. Walter P. Finn PE No.22639 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 i ® WARNING- verity design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII.7473 rev. 10/0312015 BEFORE USE Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �' a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing i'd'��° Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabricatlon, storage- delivery- erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type city Ply THE WINDSOR T13569663 M11392 A3 SPECIAL 1 1 Job Reference (optional) Chambers Truss, lnc., Fort Pierce, FL a.1 ju s iviar 11 zui o Nil i LK muusuleb, Nuu. l flu Ivldl LG — lo.vo — 16 ray6 , I ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-70kz6ucT1 ou6L5d61 D3okEmtrABCYrBwGJvBAtzYai9 1-0- 8-6.0 15-0-0 20.0-0 24-6-8 27-4-7 35.0.0 6-0- 0- 8-6-0 6.6-0 5-0-0 4-6-8 2-9-15 7-7-9 0- 3x5 14 2x3 I 4.00 12 5x6 = 4x5 = 5 R 2.00 12 Scale = 1:62.3 3A 2 : o 0 Ir� 8-6-0 14-9-0 , 20-0-0 , 24-6.8 35-0-0 8-6-0 6-3-0 5-3 0 4-6-8 10-5-8 Plate Offsets (X,Y)-- [2:0-1-6,Edge], f3:03-0,Edgel, r8:0-3-0,03-01, f9:0-1-15,Edgel LOADING (psf), SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(L-) 0.73 11 >572 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.97 11-20 >432 180 MT18HS 244/190 BCLL 0.0, ' Rep Stress Incr YES WB 0.83 Horz(CT) 0.36 9 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD !2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc puffins. BOT CHORD i2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS .2x4 SP No.3 WEBS 1 Row at midpt 7-12 REACTIONS. i'(lb/size) 2=1349/0-8-0, 9=1349/0-8-0 'Max Horz 2=-155(LC 10) Max Uplift 2=-825(LC 12), 9= 825(LC 12) FORCES. (lb),- Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4= 3256/2031, 4-5= 2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=-5320/3257, 8-9=-5720/3554 BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13= 1258/2274, 11-12=-2935/5103, 9-11= 3302/5445 WEBS 4-14=0/329, 4-13_ 897/636, 5-12= 316/661, 6-12— 317/616, 7-12=-2727/1643, 7-11 =-1 072/1939, 8-11=-390/391 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=351t; eave=sit; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members afid forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=82519=825. Walter P. Finn PE No.22639 Mi rek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111I1-7473 rev. 101012015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing n�I� : M! ek' Is always requlrod for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iT fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Infofmatton available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply THE WINDSOR T13569664 M11392 A4 SPECIAL 1 1 Job Reference o tional Industries, � Chambers Truss, Inc., Fort Pierce, FL a.las s Ivml 1 1 c� 1A 1- 1 en c. I uu a. y ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-bCILKEc6o61 zzFClawai HR12naXQHF54VyeliJzYQi8 1-0- i1 8-6-0 14-9-0 17-0-0 8-0-0 24-6-8 27-4-7 35-0-0 6-0- 0- 8-6-0 6-3-0 2-3-0 0- 6-6-8 2-9-15 7-7-9 0- Scale = 1:62.3 6 3x5 4.00 FIT 5x6 = 4x6 = �Ya I I 6 7 16 15 3x12 2x3 11 5x8 = 1:0-1-1 2.00 r12 6-6-8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.80 13 >528 240 TCDL 7.00 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.05 13 >400 180 BCLL 0.' Rep Stress Incr YES WB 0.98 Horz(CT) 0.39 11 n/a n/a BCDL 10.0 Code FBC2017/rPI2014 Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 WEBS REACTIONS. (lb/size) 2=1349/0-8-0, 11=1349/0-8-0 Max Harz 2=-175(LC 10) Max Uplift 2=-825(LC 12), 11=-825(LC 12) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD . 2-3= 3253/1989, 3-5= 2435/1560, 5-6_ 2399/1639, 6-7=-2217/1501, 7-8=-2380/1519, 8- 1 0=-5361/3228, 10-11= 5716/3480 BOT CHORD 2-1 6=- 1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154, 11-13=-3232/5441 WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-163/427, 6-14=-309/604, 6-15= 315/409, 8-14=-3146/1901, 8-13=-1 034/1946,10-13=-343/333 3x12 = PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 172 lb FT = 20% Structural wood sheathing directly applied or 2-6-14 oc puffins. Rigid ceiling directly applied or 2-2-0 oc bracing. 1 Row at midpt 8-14 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at Joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of (rearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=825, 11=825. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cori 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 10/012015 BEFORE USE. Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrlcatlom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East BNd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T13569666 M11392 A5 SPECIAL 16 1 �THEWINDSOR Job Reference o ti.o o i Chambers Truss, Inc., FortPierce, FL a.l3usrwarI12018,va,ertmuusu,ea,me. Ihurv,a,c 09.,o.,vav,vrage ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-30sjXZdkZP9gaOnU8d5GpfrA3_tBOm_DkcOIFmzYQi7 • 1 0 Q 8-6-0 14-9-0 17-6-0 24-6-8 27-4-7 35-0-0 6 V 1-0-0 8-6-0 6-3.0 2-9-0 7-0-8 2-9-15 7-7-9 0-0 dI 6 Scale = 1:60.3 4.00 12 6x8 II 6 14 13 3x5 = 2X3 5x10 = 14-9-0 2.00 F12 3x12 = I1 � n 0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) 0.80 12-13 >526 240 MT20 244/190 TCDL 7.0, Lumber DOL 1.25 BC 0.92 Vert(CT) -1.28 12-13 >329 180 MT18HS 244/190 BCLL 0:0 ' Rep Stress Incr YES WB 0.74 Horz(CT) 0.36 10 rVa n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD i2x4 SP M 31 "Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. 1-4,8-11: 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP M 30 WEBS 1 Row at midpt 6-12 WEBS 12x4 SP No.3 "Except' 6-12: 2x4 SP M 30 OTHERS 12x4 SP No.3 REACTIONS. 11(lb/size) 2=1349/0-8-0, 10=1349/0-8-0 ,Max Harz 2=-179(LC 10) Max Uplift 2=-825(LC 12), 10=-825(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=-2397/1763, 6-7=-5452/3624, 7-9=-5398/3482, 9-10=-5732/3689 BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, 12-13= 1223/2137, 10-12= 3431/5459 WEBS 3-14=0/303, 3-13=-861/619, 5-13=-216/264, 6-13= 300/527, 6-12=-2247/3526, 7-12=-323/388, 9-12=-321/306 NOTES- , 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0 zone C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates afe MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at Joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of (bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Qt=lb) 2=825, 10-825. Walter P. Finn PE No.22639 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a Inrss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing W iTeW Is always required for stability and to prevent collapse with possible personal Injury and property damage, for general guidance regarding the fabrlcatlorl, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSO.89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply i T13569666 M11392 ATA COMMON 5 1 �TIIEWINDSOR j Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8A30 s Niar 11 2018 Mi i eK inuusrnes, Inc. 1 Hu Iviar cc 09:13.1 1 20I IS Faye ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-XbQ61veMKjHhCYMgiLcVMsOOlOH61FeNyG7rnCzYQi6 'HOG Q 8-4-0 12-11-0 17-6-0 22-1-0 26-8-0 35-0-0 36-0-Q 1-0-0 8-4-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 1-0-0 Scale = 1:59.5 m rI 6 4.00 12 4x4 = 17 •- 15 -- -" 14 - 12 3x6 = 2x3 II 4x6 = 3x8 = 2x3 11 3x6 = 3x8 = 4x6 = 12-11-0 LOADING (psf), TCLL 20.0 TCDL 7.6 BCLL 0.0 BCDL 10.0' SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20171TP12014 CSI. TC 0.59 BC 0.68 WB 0.59 Matrix -MS DEFL. in (loc) I/dell Ud Vert(LL) 0.33 14-15 >999 240 Vert(CT) -0.64 14-15 >652 180 Horz(CT) 0.13 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 166 lb FT = 0% LUMBER- BRACING - TOP CHORD '2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins. BOT CHORD 2x4 SP M 30 j2x4 BOT CHORD Rigid ceiling directly applied or 5-2-15 oc bracing. WEBS SP No.3 REACTIONS. I, (Ib/size) 2=1399/0-8-0, 10=1399/0-8-0 Max Harz 2=-179(LC 10) Max Uplift 2= 775(LC 12), 10=-775(LC 12) FORCES. (lb) -Max. Comp./Max Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 56=-2801/1739, 6-7=-2801/1739, 7-9=-2807/1637, 9-10=-3404/1963 BOT CHORD 2-17=-1724/3188, 15-17— 1724/3188, 14-15=-966/2053, 12-14=-1739/3188, 10-12=-1739/318B WEBS 6-14=-560/968, 9-14= 681/524, 6-15=-560/968, 3-15= 681/524 NOTES- 1) Unbalanced, roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft L=35ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 100.01b AC'unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss Fjas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=775, 10=775. 1 'a I6 6 Welter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE w' Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not L a truss system. Before use, the building designer must verify the appllcability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing rt�1� Tek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 9N fabrlcatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/711 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply T13569667 M11392 IB COMMON 2 1 �THEWINDSOR Job Reference (optional) 00 nn•l• 10 0MA Danc 1 Chambers Truss, Inc., Fort Pierce, I-L o.1ou„v'a' , 1 av,�a^"' US "" •" "" _" 11 ID:_kfiGCA6bx7j2Sy1 HDXFw7yeZ-?n_UyFf_41 PYgixtG28ku4wc?ohOUiFW BwtPJezYai5 •F1 0 q 8-3-5 14-0-0 17-6-0 21-0-0 26-8-11 35-0-0 Q6.0-Q 1-0.0 8-3-5 5-8-11 3-6-0 3-6-0 5.8-11 8-3-5 1 0 0 c) 6 Scale=1:59.3 4.00 F12 3x6 = 1 12 I6 6 3x4 =,- 2x3 11 3x6 = 3x4 = 3x4 = 3x6 = 2x3 11 3x4 = Plate Offsets X Y -- 2:0-2-6,Ede 6:03-0 Ede 10:0-2-6 Edgel LOADING (psf), SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.11 14-15 >766 240 MT20 244/190 TCDL 7.0, Lumber DOL 1.25 BC 0.38 Vert(CT) -0.24 17-20 >715 180 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.03 10 n/a n/a BCDL 10.0: Code FBC2017/TP12014 Matrix -MS Weight: 149 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. , All bearings 0-8-0. (lb) -I Max Horz 2=-179(LC 10) !, Max Uplift All uplift 100 lb or less at joint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10� 371(LC 12) Max Grav All reactions 250 lb or less at joint(s) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3= 945/572, 5-6=-181/256, 6-7=-181/258, 9-10=-945/574 BOT CHORD 2-17=-407/878, 15-17= 407/878, 12-14=-393/858, 10-12=-393/858 WEBS 3-17=-5/301, 3-15=-819/591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592, 9-12=-5/301 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek9 connectors. This design is based only upon parameters shown, and Is for an Individual building component, not �' a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing �,/� •� .'F�9� eW Is always r§quired for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T13569668 M1 T 392 BHA BOSTON HIP 1 1 �THEWINDSOR Job Reference (optional) .. T .. � �..• n 7 llll.i�]. �r11G Dann i Chambers Truss, Inc., Fort Pierce, FL 8.130 s rviar i i cv to rvu wv i wK ri ou es, 4.00 FIT 4x4 = 57 15 58 17 56 12 59 3x6 55 9 20 60 22 3x6 ZZZ 54 8 Sx12 ; 6 x6 = 3x4 2,P1 5x12 53 4 26 3 11 16 19 1 2 6$7 63 14 ur 52 n N 1 2 28 29 ,n N O 35 42 43 34 44 45 46 47 48 32 49 31 50 51 30 3x6 = 6x8 = 6x8 = 3x6 = 3x4 = 3x4 = i 7.2-0 14-0-0 21-0-0 28-0-0 35-0-0 7-0-0 7-0-0 7-0-0 7-0-0 7-0-0 Plate Offsets (X Y)-- (32:0-3-8 0-3-01 LOADING (psi)' SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 208 lb FT = O% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32 JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23 REACTIONS. All bearings 0-8-0. (lb) ! Max Harz 2=179(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8), 28=-434(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1), 28=626(LC 1) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1692/1103, 3-4=-1051259, 27-28=-1129l710, 3-5=-441/520, 5-7=-436/514, 7-10=-436/514, 10-11= 436/514, 11-13= 436/514, 13-16=-436/514, 16-18=-436/514, 18-19=-436/514, 19-21=-382/412, 21-23=-382/412, 23-25=382/412, 25-27=-387/418 BOT CHORD' 2-35= 939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039 WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=-810/782, 19-32=-772/745, 27-32=-1484/1044, 9-10= 463/453, 20-21= 462/454 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 Ib uplift at joint 2, 1269 lb uplift at joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28. 8) Graphical purlin representation does not depict the size or the orientation of the puffin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at 7-0-0, 1584b down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206 lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at 25-11-4, and 158 lb down and 206 lb up at 27-11-4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69 lb down at: 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at 19-11-4, 69 lb down at 21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 69 lb down at 27-11-4 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 Continued on ® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addillonal temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabricallom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Solely Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job ' Truss Truss Type Qty Ply THE WINDSOR T13569668 M1 f392 BHA BOSTON HIP 1 1 �i Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.130s Mar 1 i 2018 MI I etc inausrnes, inc. Thu mar 22 ua:ra: 4 zu 1a Paye z ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-y95ENxgEcefG304FNTAC_VOwpbKzybOpfEMWOXzYQi3 LOAD CASE(S) IStandard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 36-39= 20, 1-3=-54, 3-15=-54, 15-27=-54, 27-29=-54 Concentrated Loads (lb) Vert: 35=-373(F) 30= 23(F) 42=-23(F) 43=23(F) 44=-23(F) 45=-23(F) 46=-23(F) 47= 23(F) 48=-23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53— 118(F) 54=-11 B(F) 55= 118(F) 56_ 118(F) 57= 118(F) 58=-118(F) 59=-118(F) 60= 118(F) 61— 11 B(F) 62=-118(F) 63=-118(F) © WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 101012015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verity The applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing —Tek` Is always requlred for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the .:8 fabrication, storage, delivery, erection and bracing of trusses and muss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Into imatlon available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T13569669 M11392 GRA HIP 1 1 �THEWINDSOR � Job Reference o tional cnamoers I Fuss, mc., ran rierca, rL ..... .. ...---...__ ..._. ..._'-- -- - ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-QMfcaHhsNyn7hAfSxBhRWiY_m?eChzGytu53wzzYQi2 •r10-Q 7-0-0 14-11-0 21-5-2 28.0-0 35-0-0 ? q6i 1-0-0 7-0-0 7-11-0 6-6.2 6-6-14 7-0-0 0-0 �1 6 5x8 MT18HS = 4.00 12 ' 3 22 23 3x5 I 3x6 = 4x8 = 4x8 = 24 25 4 26 27 5 28 629 30 31 32 7 Scale = 1:60.3 15 33 34 14 35 73 36 37 38 1239 11 40 41 1a 3x4 = 2x3 11 3x6 = 5x12 = 3x4 = 4x6 = 2x3 I 3x5 = 14-11-0 6-6-14 LOADING (psf)' SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.30 10-21 >792 240 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.30 10-12 >812 180 BCLL 0.0 ' Rep Stress Incr NO WB 1.00 Horz(CT) 0.09 8 rt/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 12x4 SP No.3 *Except' i 4-13: 2x6 SP No.2 REACTIONS.,' (lb/size) 2=750/0-8-0, 13=3223/0-8-0, 8=1225/0-8-0 Max Horz 2=-78(LC 6) Max Uplift 2=-448(LC 8), 13=-2442(LC 8), 8=-1159(LC 8) Max Grav 2=755(LC 17), 13=3223(LC 1), 8=1225(LC 18) 35-0-0 PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: ;Y53 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-5 oc puffins. BOT CHORD Rigid ceiling directly applied or 4-6-8 oc bracing. WEBS 1 Row at midpt 6-13 2 Rows at 1/3 pts 3-13 FORCES. (Id) -Max. Comp./Max Ten. -All forces 250 (lb) or less except when shown. TOP CHORD - 2-3=-15341729, 3-4=-1052/1347, 4-6=-1052/1347, 6-7=-1946/1834, 7-8=-2978/2565 BOT CHORD 2-15— 586/1423, 13-15=-596/1464, 12-13=-1710/1946, 10-12=-2359/2830, 8-10=-2329/2789 WEBS 3-15= 159/733, 3-13— 2917/1869, 4-13= 848/801, 6-13=-3504/3050, 6-12=-430/666, 7-12=-940/731, 7-10=-489/690 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15f; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at joint 13 and 1159 lb uplift at joint 8. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at 7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down and 155 Iblup at 15-0-12, 90 fb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-11-4, 90 lb down and 155 lb up at 19-11-4, 90 lb down and 155 lb up at 21-11-4, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-11-4, and 203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 631b down and 3 lb up at 9-0-12, 63 lb down and 3 lb up at 11-0-12, 63 lb down and 3 Ito up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at 17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-11-4, 63 lb down and 3 lb up at 21-11-4, 63 lb down and 3lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard r N N 6 Walter P. Finn PE No.22839 MTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 tinupd on pang 9 ® WARNING • Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 111II.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual bullding component not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing -MITek' is always r6qulred for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrlcafton, storage, dellvery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quallty Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply THE WINDSOR T13569669 Mt T392 GRA HIP 1 1 Job Reference (optional) (,namoers i russ, inc., rorr r-ietce, rL- ID:-kfiGCA6bx7j2Syl HDXFw7ye3KX-QMfcaHhsNyn7hAfSxBhRWiY_m?eChzGytu53wzzYQi2 LOAD CASE(S) iStandard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=-54, 3-7= 54, 7-9=-54, 16-19= 20 ConcentratediLoads (lb) Vert:3=-147(B) 7=-147(B) 15=-452(B) 13=-40(B) 4=-90(B) 10=-452(B) 22=-90(B)23=-90(B)24=-90(B) 26=-90(B)27= 90(B) 28=-90(B) 30=-90(B) 31=-90(B) 32— 90(B) 33=-40(B) 34=-40(B) 35_ 40(B) 36=-40(B) 37=-40(B) 38= 40(B) 39= 40(B)40— 40(B) 41=-40(B) ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/012015 BEFORE USE. Design valid for use only with MITek® connectors, This design Is based only upon parameters shown, and is for an Individual building component, not � a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing ' T- W Is always tequired for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply T13569670 M1 Y392 J1 MONO TRUSS 8 1 �THEWINDSOR Job Reference (optional) cnamDers Iruss,Inc., rorrrierce,rL- I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-QMfcaHhsNyn7hAfSxBhRW iYAk?oOhCgytu53wzzYOi2 -1-0.0 1-0-0 1-0-0 1.0-0 Scale = 1:6.1 ' 3x4 = LOADING (psf) I SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 5 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 180 BCLL 0.0. ` Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017ITPI2014 Matrix -MP Weight: 5lb FT=O% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD '2x4 SP No.3 REACTIONS. (lb/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical ,,Max Horz 2=48(LC 12) Max Uplift 3= 4(LC 9), 2= 140(LC 12) -Max Grav 3=11(LC 17), 2=11B(LC 1), 4=17(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vuit=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss,has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERANCE PAGE M/I-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �" a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing . MiTeW Is always r6' ulred for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the fabrication, storage- delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply WINDSOR T13569671 M1 i392 J3 MONO TRUSS 8 1 �THE Job Reference (optional) l.narnoers l Iu5s, Inc., rVII rleIGe, rL �.,a..,i.,.., ��-..�...,,...,.............. .... .,... ...... ��__.._..---•_ _�_. ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-uYD?odiV8FvzJJEeVuCg3w5LNP6_Qf466YrcSPzYQi 1 • I. -I-0-0 3-0-0 1-0-0 3-0-0 Scale = 1:9.4 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Lid PLATES GRIP TCLL 20.0' Plate Grip DOL 1.25 TIC 0.18 Vert(LL) 0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 11 lb FT = 0 LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD BOT CHORD '2x4 SP No.3 BOT CHORD REACTIONS. �,(Ib/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12) '-Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3) FORCES. (Ib� - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 3-0-0 oc puffins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for members and forces $ MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint 2 and 4 lb uplift at joint 4. Walter P. Finn PE No.22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 111II.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �' a truss system. Before use, the building designer must verify the applicability of design parametersand properly incorporate thts design Info the overall building design. Bracing Indicated Is to prevent buckling of Individual Truss web and/or chord members only. Additional temporary and permanent bracing : MiTeW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street- Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply THE WINDSOR T13569672 M1'1392 J5 MONO TRUSS 8 1 I, Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 = 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:13:17 2018 Pagel ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-MknN?zj7vZ1 gwTpg2cjvb7dNcpKF96KFLCaA_szYQiO 5-0-0 Scale = 1:12.7 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.07 4-7 >863 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.06 4-7 >964 180 BCLL 0.0 ,` Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 171b FT=0% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical Max Horz 2=123(LC 12) Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12) ;Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 13=7011t L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0�O to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girders) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9,Ib uplift at joint 4. Walter P. Finn PE No,22839 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design validfor use only wilh MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing p��T�'i �•6Y@W Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type city Ply THE WINDSOR i T13569673 M11'392 J7 MONO TRUSS 24 1 I, Job Reference (optional) GnamDers i rus6, inc., I-ori Pierce, rL 0.1 Ja 5 "di r i eV 10 rvu r en uwumi iao, It— i nu 1w 1 — —, i i c rayv i ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-MknN?zj7vZ1 gwTpg2cjvb7dRbpO696KFLCaA_szYQiO -1-0-0 7-0-0 1-0-0 7-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 20.0 i Plate Grip DOL 1.25 TC 0.47 Vert(LL) 0.17 4-7 >494 240 TCDL 7.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.19 4-7 >447 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER 11 - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=165/Mechanical, 2=315/0-8-0, 4=88/Mechanical i Max Harz 2=161(LC 12) Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC 12) Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3) FORCES. (lb)!. Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale: 3/4"=1' PLATES GRIP MT20 244/190 Weight: 23 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE'7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft L=35ft; eave=6ft; Cat. ll; Exp C; Egcl., GCpi=0.18; MW FRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 Ib uplift at joint 3, 211 lb uplift at joint 2 and 1'2 lb uplift at joint 4. Walter P. Finn PE No.22639 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only wlth MITek® connectors. This design is based only upon parameters shown, and Is form Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building dersign. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing W9TeW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrlcaflon. storage, delivery. erection and bracing of trusses and truss systems, seeANSVTPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T13569674 M11392 KJ7 MONO TRUSS 4 1 �THEWINDSOR Job Reference o floral Chambers Truss, Inc., Fort Pierce, FL B.l au s Mar i i zui a alu i ek muusines, mc. i nu mar cc vv. i o. i o 2v r o rage 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-gxLlDijlgt9hYdO1cJE88LAgbCnNuWgPZsKjXIzYQi? 1-5-0 6-8-12 9.10-1 1-5-0 6-8-12 3-1-5 3x4 = 5 3x4 = Scale=1:20.6 6-8-12 3-1-5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0' Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.04 7-10 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.08 7-10 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.24 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 38 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 20 SP M 30 WEBS 2x4 SP No.3 REACTIONS. n (lb/size) 4=127/Mechanical, 2=37910-11-5, 5=461/Mechanical Max Horz 2=192(LC 8) Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=-238(LC 8) Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD j, 2-3=-838/366 BOT CHORD 2-7= 487i798, 6-7=-487/798 WEBS 3-7=0/307, 3-6=-920/561 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss lias been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girders) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at joint 2 and'238 lb uplift at joint 5., 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-2— 54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-t0-4= 133(F= 39, 8=-39), 8=0(F=10, B=10)-to-5= 49(F= 15, B=-15) Walter P. Finn PE No,22639 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 22,2018 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 114II.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �° a truss sysiem. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addilional temporary and permanent bracing WiTe W B always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrlcall6h, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TP1I Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandra, VA 22314. Tampa, FL 33610 Symbols Numbering System � A General Safety Notes PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0 -1/1 1r For 4 x 2 orientation, locate plates 0-'lid' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. ` Plate location details available in MTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPII : National Design Specification for Metal - - Plate Connected-W6od Truss -Construction.- DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS r) C O U n. O JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSAETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek@ All Rights Reserved MiTek Engineering Reference Sheet: Mil-7473 rev. 10/03/2015 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, Individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other Interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. 13, Top chords must be sheathed or purlins provided at spacing Indicated on design. 14, Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone -Is not-sufflcient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.