HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING Florida Department of Business and Professional Regulation - Residential CONSTRUCTION Performance Method Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: �jNCT\ Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL , ANN © Permit Number: Owner: WYNNE BUILDING CROP BY Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) Z^ 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single famlily or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1260.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of, Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft 2 6. Conditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.36 101.25 ft2 SHGC:' SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC!, SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC' 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC.' Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1445.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.17 PASS Total Baseline Loads: 48.08 I hereby certify that the plans and specifications covered by Review of the plans and Z$E STq?, this calculation are in compliance with the Florida Energy specifications covered by this 1►�� _0�, Code. calculation indicates compliance 2;�```,.. with the Florida Energy Code. ti m,,,; f �� O PREPA D Y: DATE: "� `k Before construction is completed this building will be inspected for compliance with Section 553.908 r ' M O �i at7 * -" I hereby certify that this building, as designed, is in compliance Florida Energy Code. Florida Statutes. COD with the 1;11E OWNER/,�IT: BUILDING OFFICIAL: DATE: ��` DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope; leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 __-- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___- 0 1 0 31Slab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 _--- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ____ 0 1 0 51SIab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 ____ 0 1 0 6'Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ___- 0 1 0 4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 i� rnonn on1)ti_')n17 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 -_-_ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 -__- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC # V Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 14 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood ,7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood ,9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent In 10 -vP1Space CavityR_Vatje Width Et Height Et In Area Sheathing Framing RA(allie Er -action Solar Ahsnr Below rrarip% 1 NE=>SW Exterior Concrete Block - Ext InsiHEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InsfHEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsfilEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 i 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE_>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext IndIffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 SI=>N Exterior Concrete Block - Ext In9EDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InBIffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SEi >NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InSUTAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 3:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 1 I rr)PR4 RdnF_7n17 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ftz WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.36 0.25 N 32.9 ftZ 1 ft 0 in 1 ft 4 in 0.36 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.36 0.25 N 24.0 ftz 6 ft 0 in 1 ft 4 in 0.36 0.25 N 37.5 ftZ 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ftz 8 ft 0 in 1 ft4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholeh'ouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ftZ 4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 j DUCTS ---- Supply — — Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programatle Thermostat: Y Ceiling Fans: Coolin [ ]Jan Heating �X] Jan Feb f X� Feb Mar Mar A r I Apr jMa May Jun Jul rj Jun rj Jul Au AuSep ri IXI Se Oct Oct Nov Nov H Dec Dec Ventin [ ] Jan [ Feb X Mar [X] A r May Jun Jul Aug Se Oct Nov Dec Thermostat ,Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/201813:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 i 2017 - Al, IR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street:j Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce 1 ,I COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extepds from the bottom to the top of all perimeter floor framing i members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbingand wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind popong and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. ElectricaVphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrankler cover plates and w@lls or ceilings, a. in aaaiuon, inspection or log wars snaii be in accordance with the provisions of ICU-400. 4/17/2018,3:41 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I I FORM R405-2017 ji ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditiorjed floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.36 SHGC:'; SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC:; SHGC=0.21 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A , FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz Single-family b. Frame - Wood, Adjacent R=11.0 192.00 ft 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 1446 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 101.25 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 250 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 3.832 ft. 0.239 Insulation Area 14. Hot water systems Cap: 40 gallons R=0.0 1445.50 ft2EF: a. Electric 0.97 R= ft2 b. Conservation features R= ft2 None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction', through the above energy saving features which will be installed (or exceeded) in this home;ibefore final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL 3�-14 5 � F k a *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge -tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified! Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 3:41 PM EnergyGaugeO USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 � Job: -- vnrrightsoft Project Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@/\OL.COM i Project Information For: THE GRAND CARLTON WYNNE DEVELOPMEN =FTPIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, .US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh .Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Construction quality Fireplaces He Area ft 1446 Volume (ft3) 12511 Air changes/hour 0.45 Equiv. AVF (cfm) 94 Summer Design Conditions Outside db 90 , OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 150 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24753 Btuh Simplified Latent Cooling Equipment Load Sizing Average 0 Structure 3203 Btuh . Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Cool' (none) 1446 Equipment latent load 5521 Btuh 12511 0.23 Equipment total load 30274 Btuh 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF 8.5 HSPF 34600 Btuh @ 47°F 27 °F 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Cooling :Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsoftu Right -Suite® Page Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:age 1 1 ,..uick Calcs\Documents\THE GRAND CARLTON-1446.Np Calc = MJB Front Door faces: N f 'I - - wrightsoft° • RighW@ Worksheet. Job: Entire House °ate' By. QUICK CALCS, INC. 317 ST. L'UCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 Eiq�osed wall 156.2 ft 49.0 ft 3 R'oom height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft' 297.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load I number (Btuh/ftk-OF) (BtuWftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 1 A-4acis 0143 .n 4.W .: .'.2,55 503 - - 465 ,.` : 1862 .' 1184 °, - '72 72 288 183 ,'4A5.2om ` : 0.770 :n 2156 -19:31, 38 , . 0 730 ' 0 0 :0 0 ,, 13A4.s 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 ' 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 ^ .W `. 13A-0oc"s, °" 0143 "se •. 4.60 - :2 55 34 .34 136 .. ' - :. 0 �0 0 0 12/ 13A-0acs 0143 s 4.00 2.55 360 353 1414 .- .86 899 216 216 865 550 1Ac1om 1270 s 35.56, 34.77 7 7- 247 241 0 0 0 0 13A4ocs 0143 w, 400 2:55 310 237 949 603 104: 72 288 -'183 1A c1om' 1270 w: 35.'56 55.21 : 32 2 1140 17,70 ' 32 2 1140 1TL0 0. w 5 19:3 7 . 788' 0 6 077645mi 0. P 1213-0sw 6.091 - 2.55 1.28 192 192 489 246 0 0 0 , 0 C 46A30md 0.032 - 0:g0 2.32 1446 1446 1295 3354 297 297 266 689 F i i i i 22A tPl 0.989 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED oxursion 918 627 Errvelope loss/gain 14961 13349 4204 4003 12 a):I Infiltration 2887 791 848 232 b), j Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 !I Appliances/other 20DO 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 DUCt loads 32% 49% 5654 8536 32% 49% 1601 2400 Toial room load 23503. 26056 6653 7325 Air;;required (cfm) 1 1160 1160 1 1 328 326 to meet all j wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSU08101, Ae7dR.. uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 1 i I - wrightsoft I. Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. I 317 ST.LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 .Email: QUICKCALCS ,AOL.COM 1 Room name WIC KITCHEN. 2 Exposed wall O ft 01ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 54.0 ft2 1.0 x 172.0 ft 172.0 ft2 Ty, Construction U-value Or HTM Area. (ft2) Load Area number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat . Cool 6 C 13A-4ocs 4A5 tom= : 0143 .0 770 n :_ ri"' 4:00 " 21.56 2.55 ' -. 19.31 0 .. ' _ .0 0 ' 0 0: .. '0 0 :0 '0 0 0 . ' 0 •0 :0 -A 0 il's 13AAocs 0.143 a 4.00 2.55 0 0 0 .0 0 0 0 0 11 1A-c1om 11DO 13A-flocs i .. 13A-4ocs 1A-c1om 13Alocs Ave 1.270 0 390 0143 0.143 1.270 0143 1 270 a a -,, se . s s w w' 35.56 10.92 ; 4.00 4.00 35.56 4 00 35;56 87.29 11.31 . ' 2 55 2.55 34.77 2.55 5521 0 0 .. ; .. ' p 0 0 0 - 0 0 0 p 0 0 0 0 .0 0 .. p 0 0 0 0: 0 0 - p 0 0 0- 0 0 0 ,. p 0 0 U., 0 0 0 0 0 0 0 0 0 0 : .0 0 0 .0 0 0 0 0 0 0 0 W 1 : W L=�' 9 4A5-2om:. :6.77.0 w- 21.56 19.31 0 0 0 0 0 0 -0. 0 P •'4 C 'i 12C-Osw 16A-30md 0.091 0.032, - - 2.55 0.90 1.28 2.32 0 54 0 54 0 - 48 0 125 64 172 64 172 163 154 82 . 399 F I I I 22A tpl 0.989 - 27.69 0.00 64 0 0 0 172 0 0 0 l 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) '', Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Inteinal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 14 Less extemal load Less transfer Redistribution Subtotal 0 0 0 48 0 0 0 117 0 0 0 317 0 0 .0 2311 15 Duct loads 32% 49% 151 571 32% 49%1 100 1126 Total room load Air required (cfm) 64 3 174 8 1 418 21 3437 153 Of A&- „ W wrightsoft- 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 :1_uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N -�+ r �rightsoft° Right-M Worksheet °b Entire By: House ate` I QUICK CALCS, INC. B 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246676799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM.2 2 iq�osed wall 5.0 ft 34.2 ft 3 it Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions . 9.0 x 5.0 ft 1.0 x 203.5. ft 5 Doom area 45.0 ft2 203.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load j number. (Btuh/ft2L-°F). (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat. Cool 6 ( 4:00 2.55 40 40 160:-: 102 128 12t3 513 326 4A5 Zom ' ; 0 770 : n. 2156 19.31 . : 0 : ° ' . 0 p 0 i 1 13A-4ocs 0.143 a 4.00 2.55 0 , 0 0 0 80 56 225 143 1A-clom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11D0 0.390 a 10.92 11:31 0 0 0 0 0 0 0 0 W 13A40cs; .... 0143 ae. 4.00 2.55 : 0 . 0 . 0 :` r0 `34 ' :34 `136 86 yJ L- (' 13A-0oos 0.143 s 4.00 2.55 0 0 0. 0 32 ,. 32 128 81 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A�ocs ` 0143 w° 4i00 2.55 0 0 0 0 0` :0 0 A 1Ao1cm 1 270 w: 35 66 55 2t 0 0 , 0 . 0 0 0' :0 770 . w` 21,56 1931 0 0 U :. 0 '.'. p p 0 0 P II 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C' 4 " ..16A=30md " 0.032 - 0.90 2.32 45 45 40 , . 104 204 204 182 •472 F 22A-tpl 0.989 - 27.69 0.00 45 5 138 0 204 34 946 " 0 lit `.il... 1 .. .. . .. . .. 6 c)IAED wcursion -16 -85 Fsvelope loss/gain 339 190 2978 3106 12 a), Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 1 230 l i Appliances/other 0 0 Subtotal pines 6 to 13) 425 214 3571 3498 Leis. extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 490/0 1131 1104 E Tb� room load 560 3181 4702 5203 Air required (cfm) 28 14 232 232 wrigl7tsoTt''' Right -Suite® Universal 2017 17.0.14 RSU08101 A I i...ulck CalcslDocuments\THE GRAND CARLTON-1446.rup" Calc = MJB Front. Door faces: N { 1 2017-Apr-11 09:29:38 Page 3 -- wrightsoft Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 FVosed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty Construction number U-value (Btuh/ft22F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh), Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V►/ 1G 13AAocs 4A5-2om 0.143 0.770 .. n. , n 4.00 21:56 2.55 . 19.31 0 On 0 0 0.: 0 0 0 255 . 38 -217 0 869 : ' 815 552 - 730 = 13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1 1Aclom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 'I 13AAocs 0.143 se' �4.00 2.55 0 .0 0 0 0 p ' 0 '0 t-G 13AAccs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 v 1�4ocs: ' . ' 1Ac1om 0143 1.270 w� w 4.00 35.56 2.55 55c21 0 0 .0 0 0 0 0 0 206 0- 165: 0 ' 661 -0 420 0 ��-'-G3A O:TfO w 21.56 19.31. 0. 0 0 0 41 . 41 880 -'.788 P -:4A5-tom 12C-0sw 0.091 - 2.55 1.28 56 56 143 72 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 42 42 38 97 526 526 471 1220 F 22A-tpl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED excursion 1 -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 1643 298 5994 5112 Less witemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total room load 846 443 1 1 7892 7602 AirFequired (cfm) 42 20 3901. 338 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. Amk = - wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - - wrightsoftRight-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ai OL.COM 1 Room name FOYER M. BATH 2 3 Eigwsed wall Room height 7.0 ft 8.0 ft heat/cool 8.0 ft 8.0 ft heat/c6ol 4 5 Room dimensions Room area 1.0 x 50.0 ft 50.0 ft2 7.0 x 8.0 ft 56.0 ft2. Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/W-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WKS Heat Cool Gross WP/S Heat Cool 6 V1/ 13AAocs. ;4A5-2om :", 13A-4ocs 0.143 0.770 0.143 n n a 4.00 21.56 4.00 2*55 19:31 2.55 8 '. 0 48 - 8 0 27 32 0 108 20 0 69 0 p+ 0 0 p 0 ' 0. p 0 .' • 0 p 0 11 IA-c1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 W Val �---G 13A-4ocs 13A4ocs 0:143 0.143 se s :4.00 4.00 2155 2.55 0 0 6 0 .0 0 . 0 0 0 64 0 57 0 228 " 0 145 IA-c1om 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 U13A46cs -:• 1A-clom ': 0:143 1.270 w •. w �4:00 35.56 "2.55 55:21 .. 0 0,. 0 0 0 .. 0 0 0 0 0, 0- A "0 0 0 0 AA5-26m ; , .0.770 ;. w 21.56 %9 .j 0 0 ' 0 ' 0 0 0 . � 0 : ' :' 0 P 12C-Osw 0.091 - 2.55 1.28 72 72 183 92 0 0 0 0 C .16A-36md 0.032 - 0.90 2.32 50 50 45 . 116 56 56 50 130 F ,r 22A tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 W5 516 Less extemal load 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load Air required (cfm) 1202 59 787 35 1166 58 768 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� -- wrightsoft- 2017-Apr-11 09:29:38 A k Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 ...ulck CalcsIDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N ervri htsoft° Duct System Summary Jo 9 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM r-'roject intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressulrelosses Available static pressure Supply,/ return available pressure Lowest friction rate ActuaV,air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER, h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/,DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT%DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 ox0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx wri htsoft` 2017-Apr-1109:29:38 Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Mat[ Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx Wrl htsofta 2017-Apr-11 09:29:38 9 Right -Suite® Universal 2017 17.0.14. RSU08101 Page 2 +�?i ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N