FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
Florida Department of Business and Professional Regulation - Residential
CONSTRUCTION
Performance Method
Project Name: WYNNE THE GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
Street: �jNCT\
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL ,
ANN ©
Permit Number:
Owner: WYNNE BUILDING CROP
BY
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
Z^
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single famlily or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1260.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of, Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1446.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft 2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0.36 101.25 ft2
SHGC:' SHGC=0.25
b. U-Factor: Sgl, U=0.65 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC!, SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC'
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC.'
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1445.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.17
PASS
Total Baseline Loads: 48.08
I hereby certify that the plans and specifications covered by
Review of the plans and
Z$E STq?,
this calculation are in compliance with the Florida Energy
specifications covered by this
1►�� _0�,
Code.
calculation indicates compliance
2;�```,..
with the Florida Energy Code.
ti m,,,; f �� O
PREPA D Y:
DATE: "� `k
Before construction is completed
this building will be inspected for
compliance with Section 553.908
r ' M
O �i at7
* -"
I hereby certify that this building, as designed, is in compliance
Florida Energy Code.
Florida Statutes.
COD
with the
1;11E
OWNER/,�IT:
BUILDING OFFICIAL:
DATE: ��`
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope; leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V/ Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1446 11568
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
301 2408 No
0
1
1 Yes
Yes
Yes
2 WIC
63 504 No
0
1 No
Yes
Yes
3 M.BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
__--
0 1
0
2SIab-On-Grade Edge Insulatio
WIC 1 ft 0
63 ft2
___-
0 1
0
31Slab-On-Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
_---
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
____
0 1
0
51SIab-On-Grade Edge Insulatio
BATH 5 ft 0
45 ft2
____
0 1
0
6'Slab-On-Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
____
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
___-
0 1
0
4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
i�
rnonn on1)ti_')n17
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
-_-_
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
-__-
0
1
0
ROOF
/ Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
#
V Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
14 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
,7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
,9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent In
10 -vP1Space CavityR_Vatje Width
Et
Height
Et In
Area
Sheathing Framing
RA(allie Er -action
Solar
Ahsnr
Below
rrarip%
1 NE=>SW Exterior Concrete Block - Ext InsiHEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext InsfHEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsfilEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
i
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE_>SW Exterior Concrete Block - Ext InfiffDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext IndIffDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 SI=>N Exterior Concrete Block - Ext In9EDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InBIffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SEi >NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InSUTAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11
11 24
8
192.0 ft2
0.23
0.6
0
4/17/2018 3:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
1
I
rr)PR4 RdnF_7n17
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ftz
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.36 0.25 N 32.9 ftZ 1 ft 0 in 1 ft 4 in
0.36 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in
0.36 0.25 N 24.0 ftz 6 ft 0 in 1 ft 4 in
0.36 0.25 N 37.5 ftZ 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ftz 8 ft 0 in 1 ft4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholeh'ouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
HEATING SYSTEM
System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
ftZ
4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
j
DUCTS
---- Supply
—
— Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
250 ft2
Attic
65 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programatle Thermostat: Y
Ceiling Fans:
Coolin [ ]Jan
Heating �X] Jan
Feb
f X� Feb
Mar
Mar
A r I
Apr
jMa
May
Jun Jul
rj Jun rj Jul
Au
AuSep
ri
IXI Se
Oct
Oct
Nov
Nov
H
Dec
Dec
Ventin [ ] Jan
[ Feb
X Mar
[X]
A r
May
Jun Jul
Aug
Se
Oct
Nov
Dec
Thermostat ,Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
4/17/201813:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
i
2017 - Al, IR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street:j Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
1
,I
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extepds from the
bottom to the top of all perimeter floor framing
i
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbingand wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind popong and wiring-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectricaVphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrankler cover plates and w@lls or ceilings,
a. in aaaiuon, inspection or log wars snaii be in accordance with the provisions of ICU-400.
4/17/2018,3:41 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I
I
FORM R405-2017
ji
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditiorjed floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.36
SHGC:'; SHGC=0.25
b. U-Factor: Sgl, U=0.65
SHGC:; SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ftz
Single-family
b. Frame - Wood, Adjacent
R=11.0
192.00 ft
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ft2
1446
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
11. Ducts
R ft2
101.25 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
ft2
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
3.832 ft.
0.239
Insulation
Area
14. Hot water systems
Cap:
40 gallons
R=0.0
1445.50 ft2EF:
a. Electric
0.97
R=
ft2
b. Conservation features
R=
ft2
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction', through the above energy saving features which will be installed (or exceeded)
in this home;ibefore final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL
3�-14 5 �
F
k
a
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge -tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified! Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 3:41 PM EnergyGaugeO USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
� Job:
-- vnrrightsoft Project Summary Date:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@/\OL.COM
i
Project Information
For: THE GRAND CARLTON
WYNNE DEVELOPMEN =FTPIERCE, FL
Notes:
Design Information
Weather. Fort Pierce, FL, .US
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Structure
17848
Btuh
Ducts
5654
Btuh
.Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
23503
Btuh
Infiltration
Method
Construction quality
Fireplaces
He
Area ft
1446
Volume (ft3)
12511
Air changes/hour
0.45
Equiv. AVF (cfm)
94
Summer Design Conditions
Outside db
90 , OF
Inside db
75 OF
Design TD
15 OF
Daily range
L
Relative humidity
150 %
Moisture difference
61 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
17520
Btuh
Ducts
8536
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 24753 Btuh
Simplified
Latent Cooling Equipment Load Sizing
Average
0
Structure
3203
Btuh .
Ducts
2318
Btuh
Central vent (0 cfm)
0
Btuh
Cool'
(none)
1446
Equipment latent load
5521
Btuh
12511
0.23
Equipment total load
30274
Btuh
48
Req. total capacity at 0.70 SHR
2.9
ton
Heating Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Model 25HBC536A*030
AHRI ref 7914585
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 32 OF
8.5 HSPF
34600 Btuh @ 47°F
27 °F
1160 cfm
0.049 cfm/Btuh
0.50 in H2O
Backup:
Input = 7 kW, Output = 23009 Btuh, 100 AFUE
Cooling :Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Cond 25HBC536A*030
Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 12.0 EER,
15 SEER
Sensible cooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800
Btuh
Actual air flow
1160
cfm
Air flow factor
0.045
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.83
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
wrightsoftu Right -Suite® Page Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:age 1
1
,..uick Calcs\Documents\THE GRAND CARLTON-1446.Np Calc = MJB Front Door faces: N
f
'I
- - wrightsoft° • RighW@ Worksheet. Job:
Entire House °ate'
By.
QUICK CALCS, INC.
317 ST. L'UCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
Entire House
BEDROOM
2
Eiq�osed wall
156.2 ft
49.0 ft
3
R'oom height
8.7 ft d
8.0 ft heat/cool
4
Room dimensions
1.0 x 297.0 ft
5
Room area
1445.5 ft'
297.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ftz)
Load
Area (ftz)
Load
I
number
(Btuh/ftk-OF)
(BtuWftz)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
1 A-4acis
0143
.n
4.W
.: .'.2,55
503
- - 465
,.` : 1862
.' 1184
°, - '72
72
288
183
,'4A5.2om ` :
0.770
:n
2156
-19:31,
38
, . 0
730
' 0
0
:0
0
,,
13A4.s
0.143
a
4.00
2.55
128
83
333
212
0
0
0
0
1A-c1om
1.270
a
35.56
87.29
24
2
848
2082
0
0
0
0
'
11
11DO
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
^
.W `.
13A-0oc"s,
°" 0143
"se
•. 4.60
- :2 55
34
.34
136
.. ' -
:. 0
�0
0
0
12/
13A-0acs
0143
s
4.00
2.55
360
353
1414
.- .86
899
216
216
865
550
1Ac1om
1270
s
35.56,
34.77
7
7-
247
241
0
0
0
0
13A4ocs
0143
w,
400
2:55
310
237
949
603
104:
72
288
-'183
1A c1om'
1270
w:
35.'56
55.21
: 32
2
1140
17,70
' 32
2
1140
1TL0
0.
w
5
19:3
7
.
788'
0
6
077645mi
0.
P
1213-0sw
6.091
-
2.55
1.28
192
192
489
246
0
0
0
,
0
C
46A30md
0.032
-
0:g0
2.32
1446
1446
1295
3354
297
297
266
689
F i
i
i
i
22A tPl
0.989
27.69
0.00
1446
156
4325
0
297
49
1357
0
6
c)AED oxursion
918
627
Errvelope loss/gain
14961
13349
4204
4003
12
a):I Infiltration
2887
791
848
232
b), j Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
6
1380
3
690
!I Appliances/other
20DO
0
Subtotal (lines 6 to 13)
17848
17520
5053
4925
Less edemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17848
17520
5053
4925
15
DUCt loads
32%
49%
5654
8536
32%
49%
1601
2400
Toial room load
23503.
26056
6653
7325
Air;;required (cfm)
1
1160
1160
1
1
328
326
to meet all
j wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSU08101,
Ae7dR.. uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
2017-Apr-11 09:29:38
Page 1
i
I
- wrightsoft
I.
Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
I
317 ST.LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 .Email: QUICKCALCS ,AOL.COM
1
Room name
WIC
KITCHEN.
2
Exposed wall
O ft
01ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
5
Room dimensions
Room area
6.0 x 9.0 ft
54.0 ft2
1.0 x 172.0 ft
172.0 ft2
Ty,
Construction
U-value
Or
HTM
Area. (ft2)
Load
Area
number
(Btuh/ft2-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
N/P/S
Heat .
Cool
6
C
13A-4ocs
4A5 tom= :
0143
.0 770
n
:_ ri"'
4:00
" 21.56
2.55
' -. 19.31
0
.. ' _ .0
0
' 0
0:
.. '0
0
:0
'0
0
0
. ' 0
•0
:0
-A
0
il's
13AAocs
0.143
a
4.00
2.55
0
0
0
.0
0
0
0
0
11
1A-c1om
11DO
13A-flocs i ..
13A-4ocs
1A-c1om
13Alocs
Ave
1.270
0 390
0143
0.143
1.270
0143
1 270
a
a
-,, se .
s
s
w
w'
35.56
10.92
; 4.00
4.00
35.56
4 00
35;56
87.29
11.31
. ' 2 55
2.55
34.77
2.55
5521
0
0
.. ; .. ' p
0
0
0
- 0
0
0
p
0
0
0
0
.0
0
.. p
0
0
0
0:
0
0
- p
0
0
0-
0
0
0
,. p
0
0
U.,
0
0
0
0
0
0
0
0
0
0
: .0
0
0
.0
0
0
0
0
0
0
0
W 1 :
W
L=�'
9
4A5-2om:.
:6.77.0
w-
21.56
19.31
0
0
0
0
0
0
-0.
0
P •'4
C 'i
12C-Osw
16A-30md
0.091
0.032,
-
-
2.55
0.90
1.28
2.32
0
54
0
54
0
- 48
0
125
64
172
64
172
163
154
82
. 399
F
I
I I
22A tpl
0.989
-
27.69
0.00
64
0
0
0
172
0
0
0
l
6
c)AED excursion
-9
-170
Envelope loss/gain
48
117
317
311
12
a) '', Infiltration
0
0
0
0
b) Room ventilation
0
0
0
0
13
Inteinal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
2000
Subtotal (lines 6 to 13)
48
117
317
2311
14
Less extemal load
Less transfer
Redistribution
Subtotal
0
0
0
48
0
0
0
117
0
0
0
317
0
0
.0
2311
15
Duct loads
32%
49%
151
571
32%
49%1
100
1126
Total room load
Air required (cfm)
64
3
174
8
1
418
21
3437
153
Of
A&- „ W wrightsoft- 2017-Apr-11 09:29:38
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2
:1_uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N
-�+ r �rightsoft° Right-M Worksheet °b
Entire By:
House ate` I QUICK CALCS, INC.
B
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246676799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM
1
Room name
BATH
BEDROOM.2
2
iq�osed wall
5.0 ft
34.2 ft
3
it
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
Room dimensions
. 9.0 x 5.0 ft
1.0 x 203.5. ft
5
Doom area
45.0 ft2
203.5 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
j
number.
(Btuh/ft2L-°F).
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat.
Cool
6
(
4:00
2.55
40
40
160:-:
102
128
12t3
513
326
4A5 Zom '
; 0 770
: n.
2156
19.31
. : 0
: ° ' . 0
p
0
i 1
13A-4ocs
0.143
a
4.00
2.55
0
,
0
0
0
80
56
225
143
1A-clom
1.270
a
35.56
87.29
0
0
0
0
24
2
848
2082
11
11D0
0.390
a
10.92
11:31
0
0
0
0
0
0
0
0
W
13A40cs; ....
0143
ae.
4.00
2.55
: 0
. 0
. 0
:` r0
`34
' :34
`136
86
yJ
L-
('
13A-0oos
0.143
s
4.00
2.55
0
0
0.
0
32
,.
32
128
81
1Aclom
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A�ocs `
0143
w°
4i00
2.55
0
0
0
0
0`
:0
0
A
1Ao1cm
1 270
w:
35 66
55 2t
0
0
, 0
. 0
0
0'
:0 770
. w`
21,56
1931
0
0
U
:. 0
'.'. p
p
0
0
P II
12C-0sw
0.091
-
2.55
1.28
0
0
0
0
0
0
0
0
C' 4 " ..16A=30md
"
0.032
-
0.90
2.32
45
45
40
, . 104
204
204
182
•472
F
22A-tpl
0.989
-
27.69
0.00
45
5
138
0
204
34
946
" 0
lit
`.il...
1
..
..
.
..
.
..
6
c)IAED wcursion
-16
-85
Fsvelope loss/gain
339
190
2978
3106
12
a),
Infiltration
87
24
593
162
b)
Room ventilation
0
0
0
0
13
Intemal
gains: Occupants @ 230
0
0
1
230
l i
Appliances/other
0
0
Subtotal
pines 6 to 13)
425
214
3571
3498
Leis.
extemal load
0
0
0
0
Less
transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
425
214
3571
3498
15
Duct
loads
32%
49%
135
104
32%
490/0
1131
1104
E
Tb� room load
560
3181
4702
5203
Air required (cfm)
28
14
232
232
wrigl7tsoTt''' Right -Suite® Universal 2017 17.0.14 RSU08101
A
I i...ulck CalcslDocuments\THE GRAND CARLTON-1446.rup" Calc = MJB Front. Door faces: N
{
1
2017-Apr-11 09:29:38
Page 3
-- wrightsoft
Right-M Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM
1
Room name
LAUNDRY
GREAT/DINING
2
FVosed wall
6.0 ft
47.0 ft
3
Room height
8.0 ft heat/cool
9.8 ft heat/cool
4
5
Room dimensions
Room area
7.0 x 6.0 ft
42.0 ft2
1.0 x 526.0 ft
526.0 ft2
Ty
Construction
number
U-value
(Btuh/ft22F)
Or
HTM
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh),
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
V►/
1G
13AAocs
4A5-2om
0.143
0.770
.. n.
, n
4.00
21:56
2.55
. 19.31
0
On
0
0
0.:
0
0
0
255
. 38
-217
0
869
: ' 815
552
- 730
=
13AAocs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
1
1Aclom
11DO
1.270
0.390
a
a
35.56
10.92
87.29
11.31
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W 'I
13AAocs
0.143
se'
�4.00
2.55
0
.0
0
0
0
p
' 0
'0
t-G
13AAccs
0.143
s
4.00
2.55
48
48
192
122
0
0
0
0
1A-clom
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
v
1�4ocs: ' . '
1Ac1om
0143
1.270
w�
w
4.00
35.56
2.55
55c21
0
0
.0
0
0
0
0
0
206
0-
165:
0
' 661
-0
420
0
��-'-G3A
O:TfO
w
21.56
19.31.
0.
0
0
0
41
. 41
880
-'.788
P
-:4A5-tom
12C-0sw
0.091
-
2.55
1.28
56
56
143
72
0
0
0
0
C
16A30md
0.032
-
0.90
2.32
42
42
38
97
526
526
471
1220
F
22A-tpl
0.989
-
27.69
0.00
42
6
166
0
526
47
1302
0
6
c)AED excursion
1
-22
668
Envelope loss/gain
539
270
4997
4379
12
a) Infiltration
104
28
997
273
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
2
460
Appliances/other
0
0
Subtotal (lines 6 to 13)
1643
298
5994
5112
Less witemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
643
298
5994
5112
15
Duct loads
32%
49%
204
145
32%
49%
1899
2490
Total room load
846
443
1
1
7892
7602
AirFequired (cfm)
42
20
3901.
338
Calculations approved byACCA to meet all requirements of Manual .J 8th Ed.
Amk = - wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
- - wrightsoftRight-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ai OL.COM
1
Room name
FOYER
M. BATH
2
3
Eigwsed wall
Room height
7.0 ft
8.0 ft heat/cool
8.0 ft
8.0 ft heat/c6ol
4
5
Room dimensions
Room area
1.0 x 50.0 ft
50.0 ft2
7.0 x 8.0 ft
56.0 ft2.
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/W-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WKS
Heat
Cool
Gross
WP/S
Heat
Cool
6
V1/
13AAocs.
;4A5-2om :",
13A-4ocs
0.143
0.770
0.143
n
n
a
4.00
21.56
4.00
2*55
19:31
2.55
8
'. 0
48
- 8
0
27
32
0
108
20
0
69
0
p+
0
0
p
0
' 0.
p
0
.' • 0
p
0
11
IA-c1om
11DO
1.270
0.390
a
a
35.56
10.92
87.29
11.31
0
21
0
21
0
229
0
238
0
0
0
0
0
0
0
0
W
Val
�---G
13A-4ocs
13A4ocs
0:143
0.143
se
s
:4.00
4.00
2155
2.55
0
0
6
0
.0
0
. 0
0
0
64
0
57
0
228
" 0
145
IA-c1om
1.270
s
35.56
34.77
0
0
0
0
7
7
247
241
U13A46cs
-:•
1A-clom ':
0:143
1.270
w
•. w
�4:00
35.56
"2.55
55:21
.. 0
0,.
0
0
0
.. 0
0
0
0
0,
0-
A
"0
0
0
0
AA5-26m ; ,
.0.770
;. w
21.56
%9 .j
0
0
' 0
' 0
0
0
. � 0
: ' :' 0
P
12C-Osw
0.091
-
2.55
1.28
72
72
183
92
0
0
0
0
C
.16A-36md
0.032
-
0.90
2.32
50
50
45
. 116
56
56
50
130
F
,r
22A tpl
0.989
-
27.69
0.00
50
7
194
0
56
8
222
0
6
c)AED excursion
-39
-38
Envelope loss/gain
792
496
747
478
12
a) Infiltration
121
33
138
38
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
913
529
W5
516
Less extemal load
0
0
0
0
Less transfer
Redistribution
0
0
0
0
0
0
0
0
14
Subtotal
913
529
885
516
15
Duct loads
32%
49%
289
258
32%
49%
280
251
Total room load
Air required (cfm)
1202
59
787
35
1166
58
768
34
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
.� -- wrightsoft- 2017-Apr-11 09:29:38
A k Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5
...ulck CalcsIDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
ervri htsoft° Duct System Summary Jo
9 Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM
r-'roject intormation
For. THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
Extemal static pressure
Pressulrelosses
Available static pressure
Supply,/ return available pressure
Lowest friction rate
ActuaV,air flow
Total effective length (TEL)
Heating
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.285 in/100ft
1160 cfm
Cooling
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.285 in/100ft
1160 cfm
176 ft
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat[
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 560
28
14
0.364
4.0
Ox0
VIFx
22.4
115.0
st1
BEDROOM 2
h 4702
232
232
0.360
7.0
Ox0
VIFx
23.9
115.0
st1
BEDROOM -A
h 3327
164
163
0.300
6.0
Ox0
VIFx
31.8
135.0
st2
BEDROOM-B
h 3327
164
163
0.285
6.0
Ox0
VIFx
40.6
135.0
st2
FOYER,
h 1202
59
35
0.505
4.0
OxO
VIFx
4.0
95.0
GREAT/,DINING
h 3946
195
169
0.300
7.0
Ox0
VIFx
31.8
135.0
st2
GREAT%DINING-A
h 3946
195
169
0.300
7.0
Ox0
VIFx
31.8
135.0
st2
KITCHEN
c 3437
21
153
0.379
6.0
ox0
VIFx
17.0
115.0
st1
LAUNDRY
h 846
42
20
0.361
4.0
Ox0
VIFx
23.3
115.0
st1
M. BATH -A
h 768
58
34
0
0
Ox 0
VIFx
0
0
WIC
c 174
3
8
0.309
4.0
ox0
VIFx
27.0
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
Peak AVF
721
672
0.285
918
12.0
0 x 0
VinlFlx
st1
st1
Peak AVF
1043
1091
0.285
1020
14.0
0 x 0
VinlFlx
wri htsoft` 2017-Apr-1109:29:38
Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 1
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
Grille
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FIR
(fpm)
(in)
(in)
Opening (in)
Mat[
Trunk
rb1
Ox 0
1160
1160
0
0
0
0
Ox 0
VIFx
Wrl htsofta 2017-Apr-11 09:29:38
9 Right -Suite® Universal 2017 17.0.14. RSU08101 Page 2
+�?i ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N