HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGr
V.
av s �., .rfd a v�mc t ��J""
��(7s f�bC�'
�' sf �,, ✓ i
fN
,gY pig prBy
8t Lucie COWIV
F7 h
BCIS Home Log In User Registration ;Hot Topics
Submit Surcharge Stats & Facts 1 Publications ` FBC Staff BCIS Site Map Links j Search !'
axs fat
ne�1 Product Approval
R: Publi
�e
USEc User
Product Approval Menu > Product or Apolication Search > A_oolication List > Application Detail ((��
FL # FL20484-114`�
Application Type Revision JJJ!!!
Code Version 2017 ST. LUCIE COUNTY BUILDING DI SION
Application Status Approv&EVIEWED FOR COMPLIANCE
REVIEWE B
DATE
"'
Comments PLANS A D PERMIT MUST BE KEPT JOB
Archived 1;:-1 SITE OR, N0 INSPECTIQN(S) WILL BE MADE
Product Manufacturer
Address/Phone/Email
FILE COPY
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
CONCEALED FAST EVERS OR AI I ACiHIllIEN T S
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
UNION CORRUGATING COMPANY
701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 483-0479 Ext256
jstieby@unioncorrugating.com
John Stieby
jstleby@unioncorrugating.com
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Bala Sockalingam
PE-62240
Keystone Certifications, Inc.
09/07/2027
Yoosef Lavi, P.E.
i) Validation Checklist - Hardcopy Received
FL20484 RS COI CertificateIndependence. Ddf
Referenced Standard and Year (of Standard) Standard
FM 4470
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2012
2003
2012
2006
Product Approval Method Method 1 Option D
Date Submitted 08/23/2017
Date Validated 08/28/2017
Date Pending FBC Approval 09/01/2017
Date Approved 2017
summa f Products
L #
Model, Number or Name
Descri tion
20484.1
5V
Min ga., 24" wide through fastened panel over 15/32" thick
PI y ood
11 Limits ofiUse i ,' : ; :'..F
`,
Installation Instructions
FL20484 R1 II EvaluationReoortC2175 1.Ddf
Approved formse in HVHZ:,No ,' i
Approved'for use outside HVHZ:%Yes.,•
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-169
Other: Uplift load `of 71.0 astener'spacing of 24" o.c. &
Evaluation Reports
FL20484 R1 AE EvaluatlonReoortC2175 i.odf
•169:0 psf @ fasten cingiof 6", o:c.
Created by Independent Third Parry: Yes
20484.2
Advantage-Lok II
Min 26 ga., 16" wide concealed fastened panel over 7/16" thick
OSB & 15/32" & thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL20484 RS II Evaluation Reonrtc21 7 2.odf
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116
Other: Maximum uplift load of 116.0 psf @ seam fastener
Evaluation Reports
FL20484 RI AE Eva lUationReDortC2175 2.Ddf
spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA
Created by Independent Third Party: Yes
rated plywood with retainer strap.
20484.3
Aluminum Advantage-Lok II
Max 16.375" wide, nom 0.032" thick (min.) aluminum
concealed fastener roof panel over min 15/32" thick plywood
deck or 7/16" thick OSB.
= `
Limits of Use, . .. .- •.
`'„' �'`
Installation Instructions
FL20484 RI II EvaluationReoortC2175 3.Ddf
Approved for use'in,HVHZ:,-No
Approved'for`use outside=HVHZ'6 Yest "
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c.
Evaluation Reports
FL20484 R1 AE EvaluationReoortC2175 3 Ddf
and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32"
Created by Independent Third Party: Yes
plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener
spacing of 4.63" o.c. with structural sealant in 15/32" plywood.
20484.4
Aluminum SL150
Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock
standing seam metal panel over min 15/32" thick plywood
deck or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R3 II EvaluationReDortC2175 4.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86
Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and
Evaluation Reports
FL20484 Rl AE Evaluation ReDortC2175 4.Ddf
78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16"
Created by Independent Third Party: Yes
OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with
structural sealant in 15/32" plywood.
20484.5
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 Rl II EvaluationReoortC2175 5.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. &
FL20464 R1 AE Evaluation ReoortC2175 5.Ddf
124.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.6
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 113 II EvaluationReoortC2175 6.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-88.5 ( Evaluation Reports
Other: Uplift load of 56 psf for Fastening System 1. Uplift load FL20484 R1 AE EvaluationReDortC2175 6.Ddf
of 88.5 psf for Fastening System 2. Created by Independent Third Party : Yes
20484.7
ML150
Max 16.5" wide, min 24 ga. steel standing seam panel over
15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReoortC2175 7.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Maximum uplift load of 124 psf @ clip spacing of 6"
FL20484 R1 AE Eva luationReportC2175 7.Ddf .
o.c. with 180 seam, self -adhering membrane and fixed clip.
Created by Independent Third Party: Yes
20484.8
PBR or R Panel
Min 26 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RI II EvaluationReDortC2175 8.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c.
FL20484 R3 AE Eva IuationReoortC2175 8.pdf
and 161.5 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.9
SL175
Max 18" wide, min 24 ga., snap -lock standing seam metal
panel over 15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReDOrtC2175 9.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and
FL20484 RS AE EvaluationReoortC2175 9.Ddf
78.6 psf @ clip spacing of 8" o.c with felt. Uplift load of 93.5
Created by Independent Third Party: Yes
psf @ clip spacing of 12" o.c. with self -adhering membrane.
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S.,
please dick here .
Product Approval Accepts:
Credit•
Safe
security INI ETRICS
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
"26 GA. 5V PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 20484.1-R1
ROOFING
METAL ROOFING
Prepared For:
Union .Corrugating Company
701 S. King St.
Fayetteville, NC 28301
Telephone: (910)483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D.,'P.E.
Florida Professional Engineer #62240
1216 N Lansing.Ave.; Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Load Span Table.(1 Page)
Repo-allo, C2175-1
Date: 8.212017
i
I I
I
1
FL 20484.1-R1
C2175-1
8.23.2017
li Page 2 of 3
Manufacturer: Union Corrugating Company
g g p Y
i, Product Name: 5V Panel
i
Panel Description: 24" wide coverage with (5) 1/2" high ribs
li
�! Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
I I
li Deck Description: Min. 15/32" thick APA rated plywood or min. 3/a" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
II others and installed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) 169.0 psf @ fastener spacing of 6" o.c.
I!
Panel Attachment: #10-15 x 2" long wood screw with washer
At interior @ max 12" o.c. across panel width through panel rib
At panel ends @ max 6" o.c. across panel width through panel flat and rib
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
I! of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
i with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing -nay be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
I
I
i
FL 20484.1-R1
C2175-1
8.23.2017
Page 3 of 3
not applicable in High Velocity Hurricane Zone. Refer to current NOA
for use of this product in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
directory or ASTM E108/UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents: UL580 & UL1897 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T197-16, Reporting Date 5/12/16
II PANEL OVERLAP
NEW UNDERLAYMENT PANEL FASTENER
ROOF PANEL ii SEE DETAIL 2 SEE DETAIL 1 SPACING PER ALLOWABLE
UPLIFT LOAD TABLE
7MIN.
IXISfING UNDERLAYMENf"77 EXISTING SHINGLES DECK ATTACHMENT AND
(OPTIONAL) (OPTIONAL) SUPPORTS MUST BE
DESIGNED AND INSTALLED
BY OTHERS
2X_ WOOD RAFTER/JOIST/
TRUSS AT MAX. 24 O.C.
TYPICAL PANEL INSTALLATION X-SECTION
it #10-15 X 2' LONG WOOD
SCREW WITH WASHER
fl
NEW UNDERLAYMENT
II
I�
EXISTING UNDERLAYMENT
(OPTION&)I i
DETAIL 1
SCREWSWITFi WASHER X 2- LONG WOOD
I
NEW UNDI IERLAYMENT
�I
EXISTING UNDERLAYMENT
(OPTIONAL) DETAIL 2
I
26 GA PANEL
EXISTING SHINGLES
(OPTIONAL)
PLYWOOD
15/32' THICK (MIN.)
26 GA PANEL
EXISTING SHINGLES
(OPTIONAL)
PLYWOOD
15/32' THICK. (MIN.)
PLYWOOD
15/32' THICK (MIN.)
Z -Lm
z nY
d
pp
a
GENERAL NOTES:
qq
1.. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
g5
FLORIDA BUILDING CODE (FBC).
b'
e
2. ROOF PANELS SHALL BE MINIMUM 26 GA EFFECTNE COVERING WIDTH OF�n
„ -
PANEL = 24'.
-
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE. THE CODE SHALL CONTROL
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
UNION CORRUGATING COMPANY
5V Panel Uplift Loads
(Min 26 ga.)
Description
Fastener Spacing
Allowable Uplift
along Panel Length
Load
(in)
(pso
Coverage width: 24"
6
169.0
8
158.1
147.2 _
Panel Fasteners
#10-15 hex head screws with
_10 _
12
_
136.3
sealed washer
121.7
14
1
__ .-........--- -- —
Panel fasteners spaced at 12"
.... -- _-
18
- - ... _ _
94.7
o.c. across panel width
20
-------------
85.2
through ribs.
- ---.-....--.-.......--
------...—.....-...__._ ._- ..... - ..... ---
24
71.0
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure.
♦o®.attta�roetia
G�pLIN' Pi p
sy° C� E N S E '' ••,• ��ir
a7 : lJp ..
W=
Lt1
s S Q ' �? a
�• O
1216 N Lansing Ave., Suite C S1.
Tulsa, Ok.74106
918,492 5,992
Bala Sockalingam,'Ph.D., P.E.
FL 62240