APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
6110 Deborah Way, Fort Pierce FL
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Flat Section of roof change from Metal to Modified Bitumen
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1327208
BUSINESS NAME: Sunrise City CHDO Inc.
QUALIFIERS NAME: Roderick Waller
ADDRESS: 130 S Indian River Drive
CITY: Fort Pierce STATE: FL
PHONE (DAYTIME): 772-201-2850
OWNER/BUILDER INFORMATION:
ST. LUCIE CO CERT. #:
ZIP: 34950
FAX: 772-907-0420
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE: - ZIP:
FAX:
APPROVE[
2/23/2018
Florida Building Code Online
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge 1 Stats & Fac
S
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL1654-R22
Application Type
Revision
Code Version
2017
Application Status
Approved
Product Manufacturer
POLYGLASS USA
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1378 Ext242
alender@polyglass.com
Authorized Signature
Ariel Lender
alender@polyglass.com
Technical Representative
Maury Alpert
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912)429-8610
MAIpert@polyglass.com
Quality Assurance Representative
Ariel Lender
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1230
ALender@polyglass.com
Roofing
Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W. Knezevich, PE
2 Validation Checklist - Hardcopy Received
Certificate of Independence
FL1654 R22 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D6162
2008
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
ling.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhdKjvCZfSdkp/o2fxn%2fYWFx5rxA%3dp/o3d
Florida Building Code Online
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
2012
Date Submitted
09/14/2017
Date Validated
09/15/2017
Date Pending FBC Approval
09/22/2017
Date Approved
12/12/2017
FL #
Model,'Number or Name
Description
1654.1
Polyglass SBS and APP Modified
SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
R22.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular assembly over concrete deck.
FL1654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL1654-
R22.Ddf
Refer to the ER Appendix for other systems and deck
types. 2.) Refer to ER, Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
Bac rNext�
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
I�
I
I
I
l
11
II
II
https,://www.floridabu ild ing. org/pr/pr_app_dtl. aspx? param=wGEVXQwtDgvgqu2w%2bn Fg U Pv2pw6pKxAhdKjvCZfSdk%2fxn %2fYW Fx5rxA%3d %3d
f.
2/2
��TRINITY
Table II
Deck
Application
Type
Description
Page
IA
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
--,-Wood
18-1 I
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
16-2
Wood
New, Reroof (Tear -oft) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
30.11
IC
Wood
New, Reroof (Tear -Oft) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
11
1D I.
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14.15
1F-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
Af-Z I
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
29-21
%-;a' '!
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
2931
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
513 I
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
48
SC
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
5D j
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
49
SE
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
49
6A I.
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
50-52
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
52
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
6D
Gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
54-58
Base Sheet, Bonded Roof Cover
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Ijnsulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-Inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
> Structural concrete: Minimum 1-inch embedment Into pilot hole in accordance with fastener manufacturers published Installation instructions.
i
3. Unless otherwise noted, insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
Exterior Research and Design, U.C. d/b/a TrinityI ERD Evaluation Report P9290.02.08-R20 for FL1654.R22
Certificate of Authorization 09503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
PrepaW by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384.1230 Appendix 1, Page 1 of 58
TRINITY I ERD
4. Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
S. Preliminary liminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-Inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive (M-PGi): Continuous 0.25 to 0.5-Inch wide ribbons,12-Inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where Olyflond 500 is referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
�➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,12-Inch o.c.
➢ Note: When multiple layers(s) of insulation and/or coverboard are Installed in ribbon -applied adhesive, board Joints shall be staggered.
,➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to'Increase'the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in forthe equivalent thicker material listed In the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (013500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+GL)
➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min.0.5-inch thickACFoam 11)
➢ ICP Adhesives & Sealants CR-20: MDP -117.5 psf (Min. 1.0-Inch thick)
8. Bonded polyisocyanurate Insulation boards shall be maximum 4 x4 ft.
11
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance wlth FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
ievention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10for fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. F, I r mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates In a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
foof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing In accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. for Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC Is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-Inches.
IFor LWC over structural concrete, reference Is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, LLC. d/b/a Trinity] ERD Evaluation Report P9290.02.08-R20 for FL1554-RZZ
Certififate of Authorization k9503 6'" EDITION (2017) FBC NON•HVHZ EVALUATION Revision 20: 09/12/2017
Prepafed by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1Z30 Appendix 1, Page 2 ofSB
�I
l
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications
C
�lTRiNIrrJER�
- .... _ . -.. „TABLE k POLYGLAss ROOF COVERS-
Reference
Layer
Material
Application
PP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
(Base and Ply sheets, Asphalt-
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM 02178, Type IV or VI
Hot Asphalt at 20-40
Ibs/square
applied)
Note:
Asphaltwpplied sheets or insulation shall not be applied to poly film surfaced membranes.
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 Type 11, Polyglass HT Base 650
PG350 1.5-2.0
BS-CAI
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
•
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II
Polyplus 35 1.5-2.0
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshleld
at
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
•
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
S6 Type II, Polyglass HT Base 650
SBS-AA
j565, Asphalt -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type il, ElastoRex 56 G, Elastoflex S6 G FR, Elastoshield TS-G,
Hot Asphalt at 20-00
IbsJsquare
Elastoshleld TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or Insulation shall not be applied to poly film surfaced membranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type 11, Polyglass HT Base
�$B$-TA
50
(SBS, Torch -Applied)
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-G,
Torch -Applied
Cap Ply
Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
Self
(SBS, Self -Adhering)
Nate:
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply optionsherein,
-Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
I� P -CAS
Cap Ply
Polyflex G FR
PG350 at 1.5.2.0
gal/square
I'APP-Ul N
(BaSFAV.or Ply'j
�oneo—�—mpmplre—sP6lyglis APP'Bas—e,Polyflez;Polybond)
f[h-ilppli
1(APP,`TprcF APP ied)i
(Cap PR,
IPolyflei� Polyflex G Pofyflez G FR; P,iilybond Polybond-G, Polyfresko G, Polyfresko G'FR)
Tot
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
IAPP-SA
'(APP,Self-Adhering)
Note:
Unless otherwise noted, permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
D PG200 Non Fibered Roof Coating;
> PG300 Fibered Roof Coating;
D PG600 Non-Fibered Aluminum Roof Ccatng;
D PG650 Fibered Aluminum Roof Coating;
> PG700 High Quality Elastomedc Roof Coating or KM Acryl 25;
`> PG700Q5 (Quick Set) High Quality Elastomedc Roof Coating or KM Acryl 25-QS (forgranule-surfaced APP orSBS only);
D PG800 Asphalt Emulsion Roof Coating; ,
> Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
Polyplus 6S Premium Fibered Aluminum Roof Coating;
> Polybdte 70 Premium Grade Elastomedc Roof Coating orKM Acryl 15;
Polybdte 700S (Quick set) Premium Grade Elastomedc Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or Sas only);
1> Polybrte 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FU654-M
Cerdfifate of Authorization p9503 67H
EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 3 of 58
TRINITY I ERD
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. VI por barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
nMtoc.
VAPOR BARRIER OPTIONS; STRUc uRAL`CONCRETE DECK; ADHERED INSULATION PER TABLE3A
-: _ _ _.. _ -
1
'Option #
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
T e
yP
Attach
�VB-1.
PG100
Elastoflex SA V Plus
Self -Adhering
Inta-Stik or CR-20, 12-Inch o.c.
-60.0
VB-2.
PG100
Polyglass APP Base
Torch -applied
Inta-Stik or CR-20, 12-Inch o.c.
-75.0
j VB-3.
PG100
Elastoflex SA P
Self -Adhering
Insta-Stik, 12-Inch o.c.
-75.0
�VB-4.
PG100
Elastoflex SAP
Self -Adhering
Millennium One Step Foamable Adhesive, 12-Inch o.c.
.157.5
VB-S.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-6.
PG100
Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-Inch o.c.
-290.0
19. "(NDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
�i
Exterior Research and Design, U.C. d/b/a Trinity( ERD
CertifiF to of Authorization 09503
Prepared by: Robert Nleminen, PE-59166
i
I
Evaluation Report P9290.02.08-R20 for FL3654-R22
EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 4 of 58
TRINITY I ERD
TABLE IF-2: WOO D'DECKS=NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE E NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (sc m & PLATes), BONDED- ROOF COVER
Syste
Base Sheet
Roof Cover (Note 15)
MOP
Deck (Note 1)
Type
Fasten
Attach
Base Ply
Cap
(Psf)
SELF -ADHERING BASE PLY:
6
Min, 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2.7/8) with Dekfast #14
12-inch o.c. in 4-inch lap and 12-inch o.c in two
SBS-SA
SBS-SA, APP-SA, SBS-
-52.5•
Inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
TA APP TA
W-13711
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-inch o.c, in 4-inch lap and 12-inch o.c in two
Polyflex SA Base
APP-TA
-52.5•
Inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
W-1381
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. in 4-Inch lap and 12-Inch o.c in two
SBS-SA
SBS-SA, APP-SA, SBS-
_60.0•
inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
TA, APP-TA
W-139I
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c, in 4-inch lap and 12-Inch o.c in two
Polyflex SA Base
APP-TA
-60.0•
inch plywood
(poly -film top)1
1 (2), equally spaced, staggered center rows
TABLEG: WOOD DECKS— NEW CONSTRUCTION ORREROOF(TEAR-OFF)
_ SYSTEM TYPE 'F: NON -INSULATED, BONDED ROOF COVER _
System
I
co to 1)
Primer
Roof Cover (Note 15j
MOP (psfj
Joint Treatment
Base Ply
Ply
Cap Ply
W-140
L--r?
Q a 15/3Z'
None
(---�
None
�—�
!SBSSA�
(2— "analjS ESSA—SBS7
SBS-SA�APP=SX,'I 5-
'90:0
�i—J
TA;APPTAI
�TA;APPTA
(inc_;Plywood
W-141
15
(Optional) PG100
None
Polyflex SA Base
(Optional)APP-TA
APP-TA
-90.0
I I
oo d
Inch plywood
Inch
W-142
Min. 15/32-
PG100
None
SBS-SA
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA,SBS-
97.5
inch plywood
TA, APP-TA
TA,APP-TA
II
W.143
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional)SBS-SA, SBS-
SBS-SA,APP-SA,SBS-
-97.5
inch plywood
place to create continuous bond.
Elastaflex SA V FR Base
TA, APP-TA
TA, APP-TA
1
W-144WB-3000
Min. 15/32-
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
-105.0
I
inch plywood
TA, APP-TA
Min. 15/32-
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
W-145
inch plywood
(Optional) PG100
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
-135.0
W-1416
Min. 15/32-
(Optional) PG100
Plywoodjoints are covered with 4-inch wide strips of Elastoflex SAV Plus, rolled into
polyflex SA Base
(Optional)APP-TA
APP TA
-135.0
11
inch plywood
.place to create continuous bond.
I
Exterior Research and Design, U.C. d/b/a Trinity(ERD
Certificate of Authorization #9503
PrepaIred by: Robert Nleminen, PE-59166
�I
6' EDITION (2017) FBC NON-HVH2 EVALUATION
Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Evaluation Report P9290.02.08-R20 for FL1654.R22
Revision 20: 09/12/2017