Loading...
HomeMy WebLinkAboutCONSTRUCTION PLANS PAGE 76-9018" WP DINING ROOM U y PROVIDE CAT�6 CAB�E' ROVEWIFI CEIL NG 4 A-30 1" CONDUIT IN MENU BOARD WALL TO TERMINATE ABOVE CEILING. (TYPICAL) n/ --- ----------- -- - P-RING (TYPICAL) DUPLEX RECEPTACLE (TYPICAL) ', 0 L MENU BOARD SOFFIT - \- DIGITAL MENU BOARD DISPLAY REFER TO ARCHITECTURAL (BY OTHERS, TYPICAL) ELEVATIONS SHEET. i i DIGITAL MENU BOARD INSTALLATION SCALE: N.T.S. i NOTES: 1. (1) DUPLEX RECEPTACLE PER SCREEN 2. (1) P-RING PER SCREEN WITH 1„ CONDUIT TO ABOVE CEILING. DATA CABLE TO RUN TO MEDIA PLAYER(S) IN OFFICE 3. VERIFY NUMBER OF SCREENS USED (3 OR 4) PRIOR TO INSTALLATION OF RECEPTACLES AND P-RINGS. 4. DETERMINE SCREEN AND MOUNTING BRACKET MODELS PRIOR TO INSTALLATION OF RECEPTACLES AND P-RINGS. 5. REFER TO ELECTRICAL POWER PLAN SHEET FOR CIRCUITING REQUIREMENTS. ---------------- r STUB -UP ABOVE , CEILING (TYP FOR 3) �--► SOUND, POWER & i��_ ►- 18 DATA CABLE FOR DRIVE-THRU LOOP 90A lit T. 7 I i IV p wl A-35 - -----r I II, i I I I I I I I _ ------------- - RAP- DETECTOR LOOPS ARE REQUIRED ATITHE ORDER CONFIRMATION UNIT AND AT EACH OF THE DRIVE -THROUGH WINDOWS 92" 32 10 25.11 40.89 36J1" 1 i i A 1'24 -qD - B-1i4 y B6172 B-10 Bt6 q u r _24 24 = 111 6 - IL 33: 6 2 .7 7 , I. I 21.79 B 4rl . I 10� . 90" 31 B PNL-D 1©"" 94A r - - - - REFER TO ELECTRICAL 4A - �© ,� T PNL-B PNL-M 5511 9591.5� B-25 50A 84' B PNL-A /� TECHNOLOGY PLAN U Il V MAINREAKER SHEET FOR POS. SYSTEM I 20.57 51.20 37.01. A-16 'I � 2 I ,, I I 1 BUG SHUN I TRIP ELECTRICAL INFORMATION l 50.02 PNL_ A-34 10 5 1mNL-D2 B-gJA' 23B (VERIFY) (T EAP-CT CABINET )OA 55r�1 -�a © CUSTOMER )(4)'\ W/METER ABOVE PICK-UP SERVING 1 U U I 1 I 90 1 90A 1 1 1 1 © 90 \� ` 90A \ A-33 � II CORRIDO A 10 A-20 ` '-: � C OFFICE A-32 A-34 W'r 'V`N MEN U ELECTRICAL POWER PLAN SCALE: 1 /4" = 1'-0" I I ®-KEYED NOTES - ELECTRICAL POWER PLAN: 1. FRYER HOOD: PRE -WIRED (WITH RECEPTACLES BY HOOD MANUFACTURER. ELECTRICAL CONTRACTOR TO MAKE CONNECTION AT JUNCTION BOX AT THE TOP OF THE HOOD. BROILER HOOD: PRE -WIRED (WITH DUPLEX RECEPTACLES) BY HOOD MANUFACTURER. ELECTRICAL CONTRACTOR TO MAKE CONNECTION AT JUNCTION BOX AT THE TOP OF THE HOOD. ELECTRICAL CONTRACTOR TO PROVIDE RECEPTACLE AND COVER PLATE FOR THE OVEN AND BROILER BASED ON EQUIPMENT SELECTED. 2. ELECTRICAL CONTRACTOR TO RUN CONDUITS AND WIRE THROUGH THE EQUIPMENT CHASE AND CONNECT TO CIRCUITS PROVIDED IN THE JUNCTION BOX BY EQUIPMENT MANUFACTURER. 3, SWITCH GEAR OPTION #1: RECESS ELECTRICAL CONTACTOR PANEL & PANELS 'A', 'B', & 'M' IN FURRED OUT WALL ADJACENT TO EXTERIOR FRAMING. G.C. TO VERIFY PANEL SIZES PRIOR TO FURR-OUT TO INSURE ADEQUATE SPACE. SWITCH GEAR OPTION #2: HILL PHOENIX INTEGRATED WALL UNIT INCLUDES PANELS 'A', 'B', 'M' AND MASTER CONTACTOR PANEL IN ONE CABINET. UNIT TO BE SURFACE MOUNTED ON 4" HIGH CONCRETE CURB. REFERENCE TO MASTER CONTACTOR PANEL SHEET AND ELECTRICAL RISER AND PANEL SCHEDULES SHEET FOR ADDITIONAL INFORMATION. 4. REAR DOOR ALARM: "MONITOR 4000" BY SECURITY PRODUCTS, INC. OR APPROVED EQUAL. MOUNT SIMPLEX RECEPTACLE FOR POWER SUPPLY 6" ABOVE CEILING. 5. PERMANENTLY CONNECTED KITCHEN EQUIPMENT NOT SUPPLIED WITH ON/OFF UNIT SWITCH (WHICH IS PART OF THE APPLIANCE) TO SERVE AS. A DISCONNECTING MEANS. UNIT SHALL BE SUPPLIED WITH A DISCONNECT AS PER N.E.C., FURNISHED BY THE ELECTRICAL CONTRACTOR. 6. G.C. TO VERIFY ELECTRICAL REQUIREMENTS FOR FIRE SUPPRESSION SYSTEM AND AUTO-SELENOID GAS SHUT-OFF VALVE. 7. RUN 2" CONDUIT TO MANAGERS OFFICE FOR CABLE TV. 8. HEAT TAPE IS PROVIDED BY THE WALK-IN BOX MANUFACTURER AND INSTALLED BY THE ELECTRICAL CONTRACTOR. CONTRACTOR SHALL COORDINATE INSTALLATION AND SUPPLY 120V CIRCUIT AND RECEPTACLE AS DIRECTED BY BOX MANUFACTURER. 9. DIGITAL MENU BOARDS (VERIFY 3 OR 4 BOARD INSTALLATION): PROVIDE (1) DUPLEX RECEPTACLE FOR 120V CIRCUIT AND (1) P-RING FOR DATA CABLE AT EACH MENU BOARD SCREEN. REFER TO DETAIL, THIS SHEET. 10. STAINLESS STEEL SERVICE CHASE TO CEILING FURNISHED BY THE EQUIPMENT MANUFACTURER. 11. CONTRACTOR SHALL OBTAIN WIRING DIAGRAM FROM THE WALK-IN BOX MANUFACTURER AND INSTALL AS DIRECTED. 12. CONTRACTOR SHALL COORDINATED EQUIPMENT INSTALLATION WITH THE EQUIPMENT MANUFACTURER'S INSTALLATION PERSONNEL. 13. PRE -WIRED TABLES AND BRANCH CIRCUITS DISCONNECTED FOR SHIPMENT TO BE RE -CONNECTED BY ELECTRICAL CONTRACTOR. 14. ELECTRICAL CONTRACTOR TO PROVIDE CORD AND PLUG AND WIRE TO BROILER BASED ON EQUIPMENT SELECTED. 15. CONTRACTOR SHALL COORDINATE CONDUIT RUN BETWEEN FREEZER/COOLER EVAPORATORS AND ROOF -TOP REFRIGERATION UNIT WITH THE MANUFACTURER'S FURNISHED WIRING HARNESS. 16. TELEPHONE CABINET AND (2) 2" SERVICE CONDUIT STUB -UPS SHALL BE RECESSED INTO .THE WALL. VERIFY EXACT LOCATION WITH OWNER/ARCH PRIOR TO ROUGH -IN. 17. MASTER CONTACTOR PANEL. REFER TO MASTER CONTACTOR PANEL SHEET AND NOTE #23, BELOW. 18. FIELD VERIFY LOCATION AND STUB -UP (3) 1"0 CONDUIT TO JUNCTION BOXES LOCATED 12"AFF, AT BASE OF DRIVE -THROUGH ORDER STATION #1 FOR DRIVE -THROUGH COMMUNICATIONS SYSTEM, SOUND, DATA AND POWER FOR DRIVE THROUGH DETECTOR LOOP. FROM JUNCTION BOXES, PROVIDE (3) 1"0 CONDUITS WITH PULLWIRES TO ABOVE CEILING. 19. 6" BELOW CEILING FOR CONDENSATE DRAIN LINE TAPE HEATER. 20.TO MASTER RELAY PANEL. REFER TO MASTER CONTACTOR PANEL SHEET. 21. MANUAL ON -OFF CONTROL PANEL. REFER TO MASTER CONTACTOR PANEL SHEET. 22.PROVIDE FLUSH MOUNTED JBOX WITH BLANKING PLATE FOR FUTURE SELF -ORDER KIOSK. ROUTE 1/2"C W/ PULLWIRE TO OUTLET.JBOX AS SHOWN FOR FUTURE EXTENSION TO KIOSKS. SEE TECHNOLOGY PLAN FOR ADDITIONAL NOTES L-------J 3/26/18 2813E12 ROBERT L. HINKLE PE 29302 POWELL & HINKLE ENGINEERING, P.A. 1409 KINGSLEY AVENUE, BLDG 12A GALTON C. MOK PE 33192 P & H ORANGE PARK, FLORIDA 32073 LANE R. HINKLE PE 48076 (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA. REG. EB-4577 THOMAS RICHARD DAVID R. M, ELDER A. MATHEWS SPELL JR. PE PE PE 56121 59418 54729 R. Wulbern Y Architect PA �' rn� AA .0003433 Ilc y 00 (904)329-2510 tel N '2 robert@Wulbern.net• a c o c d = T n- c r0 U = � o c a�i rn� v N N w c O � r0 � yr c m Cc W L to o U 8 W Z U N a W a S2 52 W 0 W m 1 m IL O LL n r n F- a dIc G N m F- a 0 O o pp 3 Z W U Z Y W X 2 m Q X o u Oo CL goldco VERTIC C O V CD 4i cn N LO ti b cn z a aN • W 'I o ZU Yo CL7 0_ o Y W=� ��co z C=o c5 Lu W owpp J mUzL0 U) U_ z Q W 1 W 3: Wp � W J � o 0 p 1- F- w W V) E1-2 U EQUIPMENT SCHEDULE ITEM # QT .......... DESCRIPTION --------- SUPPLIED INSTALLED; VOLTS/ BY BY PHASE AMPS WATER DRAIN 15.11 1 SHAKE &SOFT SERVE MACHINE I'1 K.E.S. l K.E.S. 208/230-3 14.0201 15.0 DISPENSER 208 2 18.0 16.21 1 ICE CUB REVERAGE ii K.E.S. K.E.S. 208/230-3 12.5 1/2 ER .E. 120-1. 15 1 7.54 1 COFFEE -TEA BREWER I K.E.S. K.E.S. 1 208-1 13.0 1/2 F 19.81 i (NOT USED) EQUIPMENT SCHEDULE NOTES: 1. PRIOR TO ROUGH -IN, CONTRACTOR SHALL VERIFY ALL ELECTRICAL REQUIREMENTS AND ADJUST/PROVIDE ALL CONNECTIONS, WIRING, AND BREAKERS SIZES AS REQUIRED. 2. ALL 120 VOLT, 20 AMP RECEPTACLES LOCATED IN KITCHEN AREA SHALL BE PROTECTED BY A GFCI (GROUND FAULT CIRCUIT INTERRUPTER) TYPE CIRCUIT BREAKER. GFI TYPE OUTLETS SHALL NOT BE ALLOWED. GAS BTU NOTES I(2) DEDICATED CIRCUITS IGFCI2WITH CORD AND PLUG NEMA 'ILf -0R. WITH FEED TO REMOTE CONDENSER. WITH NEUTRAL FOR 120V LOADS. CONNECT TO ICE CUBER #16.21 WITH NEUTRAL FOR 120V LOADS, 4AIN PREP BOARD, FACING FRYERS ON PHU). KITCHEN MINDER GRAD )RIVE -THROUGH TIMERS, LEVEL LIG 1ND CLOCK TO BE CEILING MOUNTI 'ENTER DEVICES ON MAIN PREP 3Oi OVER TOASTERS, FACING ;ERVICE COUNTER CONNECT TO 'ANEL-D2. 25A MLO LOAD CENTER BY K.E.S. N1 TABLE MODULES B, C & D) NEICO BROILER TYPE 3/4 75,000 �GFCI, WITH CORD AND PLUG - iGFCI, WITH CORD AND PLUG 3/4 I 75,000 iGFCI, WITH CORD AND PLUG (WITH CORD AND PLUG GFCI, WITH CORD AND PLUG ..... (ACCESS "DESIGNWITHTHEKING" FOR ADDITIONAL HOOD OPTIONS REEZER- C.U./EVAP. IFCI, WITH CORD AND PLUG :ONNECT TO PREWIRED OUTLET #21. ONNECT TO PREWIRED OUTLET #21. ONNECT TO PREWIRED TERMINAL IN QUIPMENT #30.12 ONNECT TO PREWIRED OUTLET #21. ONNECT TO PREWIRED OUTLET #21. IITH CORD AND PLUG FCI, WITH CORD AND PLUG IFCI, WITH CORD AND PLUG CORD AND PLUG I 60/3/ N.F./3R -- WP -_ IC630/l/N.F./3R I L_0 L_ B-26 EF-2 ___7 6 30/1/N.F./3R 5, r-`- RTU 2 � 11 - I L------ BTU-3 I WP LSE I ®_RTU-1 i 9 10 S 60/3/N.F./3R 30/ N.F{/3R 9 10 L----__ M-11 I - I 3 M 10 _____--J 60/3/N.F./3R M 7 T _ �- � 60/3/N.F./3 TR U-41 O i v 11-9 10 M-9 WfJL------L I M-13 FROM BELOW Q EF30/3/N.F./3R III _,"4_©30/1/N.F./3R I -- - -- - -----------------J �® ELECTRICAL ROOF POWER PLAN SCALE: 1 /8" = l'-O" ® KEYED NOTE - ROOF POWER PLAN: 1. OPTIONAL WEATHERPROOF OUTLET 30" A.F.R. FOR TV VIDEO CAMERA. RUN CONDUIT TO BLDG. INT., VERIF SIZE AND LOCATION WITH OWNER. 2. REMOTE FREEZER COMPRESSOR CONDENSING UNIT. 3. REMOTE COOLER COMPRESSOR CONDENSING UNIT. 4. TO FREEZER EVAPORATOR. 5. TO COOLER EVAPORATOR. 6. STUB -UP CONDUIT ADJ. TO ROOF CURB AND PROVIDE SEAL TIGHT CONNECTION TO DISCONNECT WITH SUFFICIENT SLACK TO ALLOW REMOVAL OF FAN FOR SERVICING. 7. FOR CONTINUATION, SEE ELECTRICAL LIGHTING PLAN. 8. UP FROM ICE MACHINE. 9. RUN CONTROL WIRES VIA MASTER RELAY CONTROL PANEL. SEE ELECTRICAL RISER AND PANEL SCHEDULES SHEET FOR ELECTRICAL REQUIREMENTS TO MECHANICAL EQUIPMENT. 10. TIE DUCT SMOKE DETECTORS TO H.V.A.C. SMOKE ALARM SYSTEM. 11. 120V/ 10 GFCI RECEPTACLE BY ELECTRICAL CONTRACTOR ELECTRICAL CONTRACTOR (EC) - GENERAL NOTES:_ A. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES AND STANDARDS. B. ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN/NOTED OTHERWISE. C. INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEMS AS SHOWN/NOTED ON THE DRAWINGS AND PER OTHER APPLICABLE DRAWINGS/INSTRUCTIONS: REFERENCE MECHANICAL DRAWINGS. D. WIRE SIZE SHALL BE #12 (MINIMUM) UNLESS OTHERWISE NOTED. WIRE SIZES SMALLER THAN #6 AWG SHALL BE THHN/THWN. #6 AWG WIRE AND LARGER SHALL BE THW, UNLESS NOTED OTHERWISE. E. WIRE (CONDUCTOR) COLORS SHALL BE AS PER APPLICABLE CODES. F. ALL CONDUCTORS SHALL BE COPPER. : G. ALL CONDUCTORS SHALL BE RUN IN CONDUIT, EXCEPT LOW VOLTAGE CONTROL AND COMMUNICATIONS CABLES. H. ALL MATERIALS SHALL BE UL APPROVED. I. ALL BRANCH CIRCUITS, EXCEPT INTERIOR LIGHTING, EXTERIOR BUILDING SIGNS, PARAPET LIGHTING AND SOFFIT LIGHTING TO HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER NEC 250-122. J. PVC (SCHEDULE 40) PERMITTED BELOW SLAB AND BELOW GRADE ONLY. K. IT IS INTENDED THAT AN EQUIPMENT GROUND CONDUCTOR (GREEN) SHALL BE RUN IN POWER CIRCUIT CONDUITS WHETHER OR NOT THE CONDUIT IS PVC, L. ALL EMPTY CONDUITS TO BE PROVIDED WITH NYLON PULL STRING. M. NEW TYPEWRITTEN PANEL DIRECTORY SHALL BE FURNISHED AFTER JOB IS COMPLETED REFLECTING ALL AS BUILT CONDITIONS. N. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 0. ALL DATA EQUIPMENT TO BE FED BY A DEDICATED CIRCUIT WHICH CONSISTS OF A POWER CIRCUIT THAT FEEDS THIS TYPE OF EQUIPMENT ONLY WITH A SEPARATE GREEN GROUNDING CONDUCTOR CARRIED ALL THE WAY BACK TO THE PANEL TO BE CONNECTED TO THE GROUNDING SYSTEM. P. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. Q. EC SHALL VERIFY INTERIOR DECOR THEME TO BE USED AND COORDINATE WITH SAID THEME. R. EC SHALL INSTALL AND CONNECT WIRING TO ALL SIGNS. S. EC TO COORDINATED ROUGHING -IN TO ALL EQUIPMENT WITH EQUIPMENT SUPPLIER PRIOR TO INSTALLING CONDUITS. T. ALL CONDUIT RUNS TO KITCHEN EQUIPMENT SHALL BE RUN ABOVE CEILING. U. MAINTAIN 12" CLEARANCE BETWEEN P.O.S. COMMUNICATION CONDUITS AND LIGHTING FIXTURES AS WELL AS POWER CONDUITS.. V. CUTTING AND NOTCHING OF 20 BEARING WALL FRAMING NOT TO EXCEED 7/8". BORING HOLES IN 2x4 BEARING WALL FRAMING NOT TO EXCEED 2 1/8". F L ELECTRICAL CONTRACTOR EC) - H.V.A.C.: A. THE EC SHALL FURNISH AND INSTALL PITCH PANS FOR POWER AND CONTROL WIRING AND TO MAINTAIN 12" MINIMUM CLEARANCE FROM BACK PANEL OF AIR CONDITIONING UNITS. B. EC SHALL INSTALL ALL LOW -VOLTAGE CONTROL WIRING FOR ALL AIR CONDITIONING UNITS AND FANS. COORDINATE AIR CONDITIONING AND ELECTRICAL PLANS, C. EC SHALL FURNISH AND INSTALL DISCONNECTS FOR AIR CONDITIONING UNITS. D. EC SHALL USE A MINIMUM OF 4'-6" SEALTITE FLEXIBLE CONDUIT WHEN WIRING KITCHEN HOOD EXHAUST FANS ON ROOF SO THAT FANS MY BE REMOVED FROM CURBS AND PLACED ON S� ROOF FOR CLEANING EXHAUST DUCTWORK.V\ E. IF REQUIRED BY LOCAL CODE, EC SHALL PROVIDE COMPONENTS - AUDIBLE AND VISUAL ANNUNCIATORS AND SINGLE -GANG RECEPTACLES TEST STATIONS WITH GREEN AND RED LIGHT INDICATORS. EACH KITCHEN UNIT WILL BE EQUIPPED AND THE FIRE AND MECHANICAL INSPECTORS WILL DETERMINE SUITABLE LOCATION FOR TEST STATIONS. ANNUNCIATORS AND TEST STATION WILL BE LOOPED IN THE CIRCUITRY OF THE SMOKE DETECTION DEVICES. WIRING WILL BE SUPPLIED AND COMPLETED BY THE EC. ELECTRICAL CONTRACTOR (EC) -KITCHEN EOWP__MENT._ ` A. EC TO PROVIDE AND INSTALL RECEPTACLES, CAPS AND CORDS AS REQUIRED. CAPS AND CORDS ARE TO BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. B. EC TO CONNECT ELECTRICAL SERVICE DIRECTLY TO EQUIPMENT ACCORDING TO THE MANUFACTURERS'S INSTRUCTIONS. C. EC TO RECONNECT ELECTRICAL CIRCUITS ON PRE -WIRED EQUIPMENT DISASSEMBLED FOR SHIPMENT. 0" 0 D. WHERE EQUIPMENT IS NOT PRE -WIRED, EC TO CONNECT THE ELECTRICAL SERVICE AND PROVIDE INTER -WIRING AS REQUIRED. ®�N E. WHERE RECEPTACLES ARE PROVIDED WITH THE EQUIPMENT, EC TO PROVIDE AND INSTALL ELECTRICAL SERVICE DOWN FROM ABOVE THROUGH THE SERVICE CHASE PROVIDE WITH THE EQUIPMENT. 4q F. KITCHEN EQUIPMENT SUPPLIER DRAWINGS INCLUDE ONLY THOSE RECEPTACLES REQUIRED FOR SPECIFIC KITCHEN EQUIPMENT. REFER TO THE ARCHITECTS/ENGINEERS ELECTRICAL DRAWINGS FOR LOCATIONS OF UTILITY AND GENERAL PURPOSE RECEPTACLES. G. EC TO VERIFY THE UTILITY REQUIREMENTS FOR ITEMS NOT PROVIDED BY THE KITCHEN EQUIPMENT SUPPLIER. H. ALL PORTIONS OF WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND NATIONAL CODES, ORDINANCES AND STANDARDS. I. NOTIFY THE KITCHEN EQUIPMENT SUPPLIER PROJECT MANAGER IMMEDIATELY OF COMPLIANCE WITH A LOCAL, STATE OR NATIONAL CODE IS IN CONFLICT WITH THESE DRAWINGS. ELECTRICAL CONTRACTOR (EC) - WALK-IN COOLER/FREEZER: A. EC TO PROVIDE AND INSTALL A HEATING ELEMENT ON THE COOLER AND FREEZER CONDENSATE DRAIN LINES. B. EC TO CONNECT THE PRIMARY ELECTRICAL SERVICE TO THE CONDENSING UNITS AND INTER -WIRE TO THE EVAPORATOR COIL(S), CONTROLS, LIGHTING FIXTURES AND DOOR PERIMETER HEATERS. 1/10/18 2813E21 POWELL & HINKLE ENGINEERING, P.A. ROBERT L. HINKLE PE 29302 H 1409 KINGSLEY AVENUE, BLDG 12A GALTON LANE R. C, MOK HINKLE PE 33192 ORANGE PARK, FLORIDA 32073 PE 48076 (904) 264-5570 FAX:(904) 27872646 THOMAS M. ELDER PE 56121 ,RING CORPORATION FLA. REG. EB-4577 RICHARD A. MATHEWS PE 59418 DAVID R. SPELL JR. PE 54729 SEAL ttt4tpgttUaiflllRtlrAf4tp{q,/9Fr's "0.4807 ,rd,1. STAI-P off.eo naa:w�� � _I T R. Wulbern Architect PA O O AA - 0003433 Ile 10 U (904)329-2510 tel Al? 2 robert@wulbern.net e O f) 0 O N 01 C N a� c o � W rn :t N .` > C11 y N o d o rn N N w v m a) w m y N -0 c C� G N rn� �N m o `m O U a d E E An U 0 Z z � o N 0 YLu z z 0 CL m m 0U. r w in O ` sM N in o 0 0 d rl > w 1- Y C s N m I- < MCD O O z W U z 3 ::e w L - < 2 Q 0�00� goldco . VERTIC L O V J W N cn Of N z a QN Of rn LU "It O 1 `" Z Ucli Y 0 Z_ �O W = �UO�5 LV U E-I z 0 0 LU -�°� no 0) m 0 Z 006 Lu U Z W CZ ) W LLJ a w LLJ J H F- LU w cn E21111111111111l1 D/T COMMUNICATIONS BACKDOOR ANTENNAS (2) ALARM INTERFACE SECURITY CAMERA CONTROL BOX B NOTE: E3- G.C. TO VERIFY POWER AND 12 C DATA REQUIREMENTS WITH A E3-1 EC OWNERS EQUIPMENT VENDORS, E 3- E3- o CONVENIENCE l i I FOR BACKDOOR W/ 3/4 ALARM CONDUIT 111�I111.11111VI�TIlu1111111'I�'llllilllllll Il,i�l 2 1/2"0 HOLE J KEYPAD / 60 A.F.F. RECEPTACLE) I I I BY G.C. A-24 OFFICE PLAN ELEVATION E SCALE: 3/8" = i'-0" SCALE: 3/8" = QUADPLEX RECEPT. P-RING DUPLEX RECEPT. FOR FAST TRACK DUPLEX RECEPT. FOR ACCUVEW y ACCUVIEW SWITCH----F-� 4 FAST TRACK BOTTOM ® 58" A.F.F.- MWS MONITOR DUPLEX RECEPT. FOR HEADSET CHARGING_.. ® 6 0 " A.F.F. �iP►11 A-38 B-3 2 GANG P-RING 8 $ o PHONE JACK'. RACK FOR MUZAK UAT 82' A.F.F. HEADSET CHARGING RACK FOR P.O, S. A-24 BOTTOM ® 66' A.F.F. a I � -F, - SECURITY MONITOR u 0 A ELEVATION SCALE: 3/8" = V-0" (WALL MOUNTED) PRINTER g DUPLEX RECEPTACLE (TYPICAL) TO RECEPTS. P-RING DUPLEX PHONE JACK. (2) DUPLEX RECEPT. FOR SECURITY SYSTEM. 0 ELEVATION C SCALE: 3/8" = V-0" 1 1/2" CONDUIT TO ABOVE CEILING FOR P.O.S. DATA CABLES — P-RING, HORIZONTAL, TIGHT TO TOP PLATE (TYPICAL) P.O.S. BY OWNER 1" CONDUIT SMOKE DETECTO ALARM PANEL A-18 i B ELEVATION SCALE: 3/8" = V-0" D ELEVATION SCALE: 3/8" NOTE: 1. REFER TO ELECTRICAL POWER PLAN SHEET FOR ADDITIONAL INFORMATION 2. POWER IS REQUIRED FOR "CINNABON" DISPLAY UNIT. VERIFY REQUIREMENTS WITH THE MANUFACTURER. CASH REFERENCE E1,-2 36" SHELVING UNITS ` 48" SHELVING UNITS FOR POS CIRCUITING FLOW \ B KITCHEN SIDE COUNTER ELEVATION 0" I — REFERENCE ELECTRICAL POWER PLAN SHEET FOR EQUIPMENT CIRCUITS -----------, I I I I I y- ,3 r NOTE: ' REFER TO FRONT COUNTER . ..... .-•- PLAN AND ELEVATIONS FOR LOCATIONS OF POS RECEPTACLES & E1-2 FOR EQUIPMENT RECEPTACLES. F 1 I I II I I I' 1 I III L , � 111 I F 1"C DATA-[ -----------------, I I II I I I I I tn, I IIt I I II I I B-5 IL JI 1 11-_ 'I I I I II - _ ......... y - i .- L. I I 4 I r I I I a�r M I I 1, If —zIf 4 u I IN (2) 2X4 BRACING ACROSS TRUSSES TO BE PROVIDED BY G.C. I .I Illl .. ..... II O RECESSED ,nT� I -BOTTOM CHORD OF TRUSS DUPLEX LAY -IN CEILING (TYP) BY G.C. RECEPTACLE MONITOR BRACKET ASSEMBLY PROVIDED BY P.O.S. SUPPLIER/INSTALLED BY G.C. HANGING VIDEO BRACKET SCALE: NO SCALE . if _TIE,) v I ; I I ' ® TECHNOLOGY PLAN GENERAL NOTES: SCALE: 1/4" = 1'-0 NOTE: B REFER TO ELECTRICAL POWER PLAN SHEET FOR E3-I ADDITIONAL INFORMATION SERVICE COUNTER PLAN SCALE: 1 /2" = 1'-0" A. CONTRACTOR TO VERIFY WHICH SYSTEM IS TO BE INSTALLED. REQUIREMENTS CAN VARY DEPENDING ON MANUFACTURER. THE CONTRACTOR IS CAUTIONED TO VERIFY ALL REQUIREMENTS PRIOR TO CONSTRUCTION. B. CONTRACTOR TO PROVIDE ALL RECEPTACLE OUTLETS, CONDUITS AND J-BOXES AS INDICATED ON PLAN. C. CONTRACTOR TO VERIFY AND COORDINATE LOCATION OF VIDEO DISPLAY DEVICES W/ BURGER KING REPRESENTATIVE. D. MAINTAIN P.O.S, CABLES A MIN. OF 12" AWAY FROM ANY FLUORESCENT LIGHT SOURCES ABOVE CEILING. E. ELECTRICAL CONTRACTOR TO IDENTIFY P.O.S. JUNCTION BOXES ABOVE CEILING "GROUND P.O.S. ONLY". ®-KEYED PLAN NOTES: 1. DISPLAY #1 AND BUMP BAR, PROVIDE 4"0 CONDUIT FOR VIDEO, BUMP BAR AND PRINTERS. PROVIDE CEILING MOUNTED RECEPTACLES. (TYPICAL FOR DISPLAY #1, #2 AND #3) 2. DISPLAY #2 AND BUMP BAR AV 3. DISPLAY #3 AND BUMP BAR 4. STOCK LEVEL LIGHT CONTROLLER 060" A.F.F. 5. TOTAL SERVICE TIME DISPLAY 6. GRADE DISPLAY 7. CLOCK-RECEPT. IN CHASE 8. STOCK LEVEL DISPLAY RECEPT. IN CHASE 9. EQUIPMENT MOUNTED RECEPTACLES BY K.E.S. CIRCUITING RUNS BY E.C. 10. J-BOX W/ 3/4" CONDUIT 0 84" A.F.F. 11. CEILING MOUNTED D/T TIMER WINDOW TIME DISPLAY 12. 90" A.F.F. FOR D/T LAND MONITOR. 13. P-RING ® 24" A.F.F. W/ 1" CONDUIT TO ABOVE Cl " 14. J-BOX W/1" CONDUIT TO ClFOR PHU DATA CABLE. Tar (LOCATE NEXT TO PHU RECEPT.) Ne 15. SECURITY CAMERA (TYPICAL) 16. SECURITY MONITOR (TYPICAL) 17. PROVIDE FLUSH MOUNTED JBOX WITH BLANKING PLATE �i,Jl FOR FUTURE SELFOORDER KIOSK. ROUTE CONDUITS W/PULLWIRES BACK TO I.T. ROUTER AS REQUIRED. 11(01 18 3 26 / 2813E31 ROBERT L. HINKLE PE 29302 POWELL & HINKLE ENGINEERING, P.A. GALTON C. MOIL PE 33192 1409 KINGSLEY AVENUE, BLDG 12A P & H LANE R. HINKLE PE 48076 ORANGE PARK, FLORIDA 32073 (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA, REG. EB-4577 THOMAS RICHARD DAVID R. M. ELDER A. MATHEWS SPELL JR. PE PE PE 56121 59418 54729 SEAL R1 lt 48CJ76 ryry� �r m VA? m.,,:,. R. Wulbern Architect PA AA • 0003433 Tic . m U (904)329.2510 tel . m U robert@wulbern.net. a m CID m � y N� c v m m a c m me .y pl o o m U ID c d L m E � m y � �0 Z z CL W N Y 0 z a a wf S2 w R CWWD > m > m O 0 w Q p�p� O O N 0 0 0 .= G N r, m Imo- r i O O o� z \c) W U a = °`ate 0 L) O a goldco . VERTIG IL i� O t� J W %ft.00 N N Q Q g uNi �rn O co ZU Yo C� _j to ZJ _j _W�}} O 0 U) LL'^I U E-' = o V j W oC��°� no rrl 00 J m �JzLLOO fJ z m Q LL L O U J WU O Z W LLI J F- o 0 p w w s E311111111111,1 "MORNING ARRIVAL" STEP 1 TURN THE UN-OCCUPIED/OCCUPIED SWITCH TO THE THE OCCUPIED POSITION. THE AIR CONDITIONING SYSTEM WILL GO FROM NIGHT SETBACK MODE TO THE THERMOSTAT SET POINT. NOTE: THE AIR CONDITIONING FAN WILL START AND RUN CONTINUOUSLY. EXHAUST FAN WILL NOT RUN UNTIL THE SWITCH IS IN THE OCCUPIED POSITION. STEP 2' TURN ON THE EXHAUST FAN SWITCH TO THE ON POSITION THIS WILL ALLOW YOU TO TURN ON THE FRYERS AND BROILER. "RESTAURANT OPEN FOR BUSINESS" TURN THE DINING UNOCCUPIED -OCCUPIED SWITCH TO THE OCCUPIED POSITION, THE DINING AIR CONDITIONING SYSTEM WILL GO FROM NIGHT SETBACK MODE TO THE THERMOSTAT SET POINT. TURN THE SIGN AND PARKING LOT LIGHTING SWITCHES TO THE AUTO POSITION, THIS WILL ENGAGE THE LIGHTING PHOTOCELLS SO THAT THE LIGHTS WILL AUTOMATICALLY COME ON AFTER DARK. TURN THE SWITCH TO THE ON POSITION TO OVER RIDE THE PHOTOCELLS AT ANY TIME THE LIGHTING MUST REMAIN ON. "RESTAURANT CLOSE FOR BUSINESS" . STEP 1 ' TURN THE DINING UNOCCUPIED -OCCUPIED SWITCH TO THE UNOCCUPIED POSITION.' THE DINING AIR CONDITIONING SYSTEM WILL GO FROM THE THERMOSTAT SET POINT TO THE NIGHT SETBACK MODE. TURN THE SIGN AND PARKING LOT LIGHTING SWITCHES TO THE OFF POSITION, THIS WILL DISENGAGE THE LIGHTING PHOTOCELLS. STEP 3 TURN THE EXHAUST FAN SWITCH TO THE OFF POSITION THE EXHAUST FAN WILL CONTINUE TO RUN FOR 15 MINUTES FOR A COOL DOWN CYCLE, AND THEN SHUT OFF AUTOMATICALLY. NOTE: THE FRYERS AND BROILER SHOULD BE TURNED OFF AND ALLOWED TO COOL DOWN BEFORE TURNING THE HOOD OFF. TO PREVENT ACCIDENTAL ANSUL DISCHARGE, THE HOOD WILL ALWAYS RUN 15 MINUTES AFTER THE EXHAUST FAN SWITCH IS TURNED TO THE OFF POSITION. "EMPLOYEES LEAVING THE BUILDING" STEP 1 WHEN READY TO EXIT THE BUILDING PUSH THE SECURITY DEPARTURES SWITCH. THE PARKING LOT LIGHTS WILL COME BACK ON FOR 15 MINUTES THEN SHUT OFF AUTOMATICALLY. "MANAGER/LAST PERSON LEAVING THE BUILDING" STEP 1 TURN THE UN-OCCUPIED/OCCUPIED SWITCH TO THE UN -OCCUPIED POSITION. THE AIR CONDITIONING SYSTEM WILL GO FROM THE THERMOSTAT SET POINT TO THE NIGHT SET BACK MODE. WHEN READY TO EXIT THE BUILDING PUSH THE SECURITY DEPARTURE SWITCH. THE PARKING LOT LIGHTS WILL COME BACK ON FOR 15 MINUTES THEN SHUT OFF AUTOMATICALLY. "HOOD VENTILATION SYSTEM NOTE" WHEN THE HOOD EXHAUST FAN CURRENT SENSOR DETECTS A DROP IN AMPERAGE (SUCH AS A BELT BREAKING) IT WILL DISABLE THE LINE VOLTAGE TO THE EXHAUST FAN(S), FRYER AND BROILER APPLIANCES. THE EXHAUST FAN SWITCH SHOULD BE PLACED IN THE OFF POSITION AND THE FAN SHOULD BE CHECKED AND/OR REPAIRED BEFORE TURNING THE SWITCH TO THE ON POSITION. "PARKING LOT LIGHTING NOTE" WHEN THE PARKING LOT LIGHTS ARE TURNED OFF, THEY MUST COOL DOWN FOR ABOUT 10 MINUTES BEFORE THEY WILL COME BACK ON. *NOTE: IF IT IS NECESSARY TO ADJUST THE AMPERAGE OF THE BROILER EXHAUST HOOD FAN MOTOR, THE FAN MOTOR CURRENT SENSOR MUST BE RESET AS FOLLOWS: ADJUST UNDERCURRENT POTENTIOMETER TO MINIMUM (CLOCKWISE IS MAXIMUM.) APPLY CURRENT. ONCE CURRENT IS STABILIZED, DECREASE UNDERCURRENT POT UNTIL RED LIGHTS. WITHIN SEVEN SECONDS TURN DOWN UNTIL RED LIGHT TURNS OFF. IF A LIGHT REMAINS ON FOR MORE THEN TEN SECONDS, DISCONNECT SUPPLY VOLTAGE TO RESET. SEE INSTALLATION INSTRUCTIONS ON MRP COVER. CONTRACTOR PANEL TO EXHAUST FAN CURRENT SENSOR (ECS SERIES) FIELD WIRING. © COPYRIGHT 2009 NCA MASTER RELAY PANEL FAN MOTOR _. TO CONTACTOR DISCONNECT TERMNAL8 -_-. -_. -_.. VENTALATION L-P MOTOR CURRENT SENSOR (LOCATED AT EXH. FAN ON ROOF) ® 0 LOOP ONCE THROUGH SENSOR 1 REFERTOTIONNDADJURMANUFAOTURER UCTI ODT .' FOR ALL OMER INQUIRES FOR ALL QTNER INQUIRES CONTACT NCA TOLL FREE ATr (B]])33b00]R - O - - CURRENTIw H + CYRRfM MIITCX CURRENT SWITCH TERMINALS 208/'3160 (LOCATED IN NCA MASTER RELAY PANEL) (CAUTION: VERIFY ALL POWER SOURCES HAVE BEEN TURNED OFF BEFORE BEGINNING INSTALLATIONII) ONE: REMOVE FACTORY SUPPLIED JUMPER WIRE JOINING TERMINALS 1 AND 3. TWO: CONNECT CONDUCTOR FROM T_1 (LOCATED ON CONTACTOR) DIRECTLY TO CURRENT SENSOR TERMINAL 1. THREE: CONNECT CONDUCTOR FROM TERMINAL 1 (ON CURRENT SENSOR) AND ROUTE THROUGH THE SENSOR LOOP (ON CURRENT SENSOR) THEN TO L_7 (LOCATED AT DISCONNECT). FOUR: CONNECT TERMINAL T=2 (LOCATED ON CONTACTOR) DIRECTLY TO TERMINAL L_2 (LOCATED AT DISCONNECT). FIVE: ROUTE CONDUCTOR FROM TERMINAL T_3 (LOCATED ON CONTACTOR) TO TERMINAL L_3 (LOCATED AT DISCONNECT) THEN TO TERMINAL 2 (ON CURRENT SENSOR). SIX: CONNECT TERMINALS MARKED CS1 (LOCATED IN SUNCOAST PANEL) DIRECTLY TO TERMINALS 3 AND 5 (LOCATED ON THE CURRENT SENSOR). CONTRACTOR PANEL TO EXHAUST FAN CURRENT SENSOR (ECS SERIES) FIELD WIRING. © COPYRIGHT 2009 NCA MASTER RELAY PANEL FAN MOTOR CONTACTOR . DISCONNECT TERMINALS ._ L.2 VENTALATION FAN MOTOR I U I CURRENTSENSOR (LOCATED AT EXH. FAN ON ROOF) '.i O LOOP ONCE UGH TENO .SENSOR REFER TO CURRENT SENSOR MANUFACNRER QAT FOR OPERATION AND ADJUSTMENT INBTRUCTIONB FOR ALL OTHER INQUIRES CONTACT NCA TOLL FREE AP(BTT)490A0]S O} AI ., � '-- r� + cUwvexr Ewrtcx 0 -- C, cuulex]Ewecx CURRENT SWITCH TERMINAL ,4 �R 208/ 1 /60 (LOCATED IN NCA MASTER RELAY PANEL) (CAUTION: VERIFY ALL POWER SOURCES HAVE BEEN TURNED OFF BEFORE BEGINNING INSTALLATION(() ONE: REMOVE FACTORY SUPPLIED JUMPER WIRE JOINING TERMINALS 1 AND 3. TWO: CONNECT CONDUCTOR FROM T_1 (LOCATED ON CONTACTOR) DIRECTLY TO CURRENT SENSOR TERMINAL 1. THREE: CONNECT CONDUCTOR FROM TERMINAL 1 (ON CURRENT SENSOR) AND ROUTE THROUGH THE SENSOR LOOP (ON CURRENT SENSOR) THEN TO L_I (LOCATED AT DISCONNECT). FOUR: ROUTE CONDUCTOR FROM TERMINAL T_2 (LOCATED ON CONTACTOR) TO TERMINAL L_2 (LOCATED AT DISCONNECT) THEN TO TERMINAL 2 (ON CURRENT SENSOR). FIVE: CONNECT TERMINALS MARKED CSi (LOCATED IN SUNCOAST PANEL) DIRECTLY TO TERMINALS 3 AND 5 (LOCATED ON THE CURRENT SENSOR). R2 0� 24V CIXN7ROL...-...__�R-__.._.. __.. _- R3 - CK1 _. EVAP FAN CKGN COOLING 1 -_ L, --_ , ..-_. Y1 _... y1 COOLING 2-._ __.. Y2 ..____ Y2 COOLING 3 --- Y3 -- . Y3 -- Y3 _- COOLING 4 - Y4 - -FY4 y® - ... HEATING 1............ W1 .... ,._ `.. W1 .._. W1 HEATING 2_._— HEATING 3._...... W3 __-. ...._. __-� ......... W- HEATING 4 -__ W4 24 VOLT CCMAON-©------ ,.,©-_..____-___I]-._-- SPARE8 "SPARE SPARE - 10 LOW VOLTAG E / CONTROL CABLE 18/ 10 LOW VOLTAGECONTROL CABLE _ RTU AIR/COND. ON — OFF PANEL SPARE COOLING 4 COOLING 3 - Y3 -- CLK2 COOLING 2 -- Y2 - CLK7 HEATING I- Wi - R52 - - RS2 COOL I NG 1 - Yi 1.11 .1 1-- R51 -- R51 EVAP FAN --© RS+V - -- RS+V 24Y CONTROL-® HEATING 1 --- © -- T— STAT FACTORY PRESET COOLING OCCUPIED UNOCCUPIED 73 DEGREES 80 DEGREES HEATING OCCUPIED UNOCCUPIED 70 DEGREES 82 DEGREES REMOTE SENSOR HEATING 2 - 0' ..--- (IF USED) 1� HEATING 3 -FW3 -- - I VERIFY BUILDING HEATING 4 --W4 -- VOLTAGE AND SET TRANSFORMER AS CLOCK z - cKCN -- -- NEEDED CLOCK 1 RTU T—STAT LOW VOLTAGE CONTROL WIRING, T—S- ON/OFF CONTROL PANEL WIRING WHITE _ 0 _. NEUTRAL WHITE In POSE11 R BLACH BLACK .B. ., RED 3 LOT -AUTO IR "TWO HOOD STORE" A SWITCH-3 LOT LIGHTS R-5L SAFETY AN3UL SAFETY R-4 DI NING FAN - R-3 I KHEN FAN ;S DINING SETBACK KITCHEN SETBACK GREEN ANSUL PROVE _.._—BLU MASTER RELAY PANEL WIRING FIE(,D WIRING VIA �3/4 EMT PIPE (RANCH CIRCUIT DISCONNECT N ACCORDANCE WITH NEC (UL 189 LISTED 20A BREAKER)' NEUTRAL MICRO SWITCH I + BLACK .I SNITCH­-2 CING GNLIGHTSTCHENYENTILATION DINNING VENTILATION UNOCC. OCC. UNOCC. OCC. AUTO OFF ON AUTO OFF ON ..:..,, pINING KITCHEN BLDG LIGHTS LOT LIGHTS A/C UNITS A/C UNITS BUILDING CONTROL SECURITY DEPARTURE SWITCH GREEN l _.,I1 __ ,......._. �. .-..._._....... OFF 0 RED/GREEN......... ❑ ■ ❑ ■ BROILER FRYER m EXHAUST FANS DROWN T TIME DELAY ORANGE 6 RELAY . SW I 2 3 BLACK SWITCH-5 SWITCH-4 FRYER BROILER C-3 C-4 •6 .7 1 -_..._..-i1 U3. ..... ......... 951-'196_EX O.. _.:_. THERMAL TIME -DELAY OVERLOAD RELAY r BROILER FAN CURRENT SENSOR CONNECTION CSi C 5 BROILER 120v 120Y PHOTO -CELL NUMBER-2 EXHAUST FAN,2. qI, rFRYER FAN CURRENT SENSOR CONNECTION R-4p 1 CS2 .........' .. CS2 ........ C_6 _. FRYER CONTROL AC-1 AC-2 AC-3 REMOVE JUMPER IF SMOKE ANSUL CONTACTS LOCATED AT HOODS FIRE IN SMOKE DETECTOR AUX. RELAY TERMINALS 6 & 16 6 1,1.16 6 1 ,116 AC-4 AC-5 PANEL SCHEMATIC DIAGRAMS ELECTRICAL CONTRACTOR NOTES- 1. RUN ONE (10) CONDUCTOR 18 GAUGE THERMOSTAT CABLE FROM THE ROOFTOP AIR CONDITIONING UNIT TO THE "ON -OFF" PANEL. 2. RUN ONE (10) CONDUCTOR 18 GAUGE THERMOSTAT CABLE FROM THE "ON -OFF" PANEL TO THE THERMOSTAT LOCATION. 3.RUN ONE (10) CONDUCTOR 18 GAUGE THERMOSTAT CABLE FROM THE ROOFTOP AIR CONDITIONING UNIT TO THE NIGHT SETBACK THERMOSTAT LOCATION, IF NOT CONTROLLED WITH P-374-2700 T-STAT. REFER TO HVAC FLOOR PLAN SHEET 4. TERMINATION OF ALL 24 VOLT AIR CONDITIONING CONTROL WIRING SHALL BE DONE BY THE MECHANICAL CONTRACTOR. 5. ELECTRICAL CONTRACTOR SHALL RUN LINE VOLTAGE FROM THE CURRENT SENSOR LOCATED IN THE BROILER HOOD EXHAUST FAN TO THE CONTACTOR PANEL LOCATED BY. THE SWITCHGEAR. 6. FOR EACH UNIT, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ONE SINGLE -GANG RECEPTACLE TEST STATION FOR THE T-STAT, AND ONE DOUBLE -GANG RECEPTACLE TEST STATION FOR THE ANNUNCIATOR, WITH GREEN AND RED LIGHT INDICATORS. THE FIRE AND MECHANICAL INSPECTORS WILL DETERMINE SUITABLE LOCATION FOR CIRCUITRY OF THE SMOKE DETECTION DEVICES. WIRING WILL BE SUPPLIED AND COMPLETED BY ELECTRICAL CONTRACTOR. OCCUPIED -UNOCCUPIED CONTROL PANEL-18"WX18"hX4"d L NE SIDE '4 ^ POLE CONTACTOR OO 00 120V COIL 30A�� 00 00 D 1 OO Z 00 00 LDf RDIE LI '_ 00 00 .... ....! 00 00 '4 POLE CONTACTOR'. CD z 0,0 00 120V COIL 30A 0,0 °o 0o C-3 J 0,0 30A auuDlxD u O0,. I4 POLE CONTACTOR O 0 120V COIL 30A Z: 00 00 c-s <-- 00 p, x o 00 Wv 3 OA eJI LDIIC LI dIR Ii4 POLE CONTACTOR 120V COIL 20A WJ C-7-I 190p1 OpUZI p i_i O: ''. rRM3 '.. LL m---30A 14 POLE CONTACTOR Q`Q 120V COIL 20A I o_� M51 O IEDD T O ¢ � z 0 0; Oo1 - - LOAD SIDE 14 POLE CONTACTOR] ^ 120V COIL 30A 010 C-2 0 Yn qq O, 0 a 0 0 z LOT raE uaxrs 00_ — _-. 00 00'.. 4 POLE CONTACTOR O 00 1- 0' h 120V COIL 30A 00 z 00 C 4 00 00 _ 00 u 00 J SJI LDIN, LIM115 30A 00 '..4 POLE CONTACTOR',, 00 00 120V COIL 30A O 0.. Z 1 00 G-6 00 � 1� xo 30A BROILER 00 00 d 4 POLE CONTACTOR'. O 0'. W 00 W J^ -120V COIL 20A p' C-8 30A `mom OAS VALVE r, V, �4 POLE CONTACTOR Wo^ 0 6 w Z � 120V COIL 20A, 30AULo MS- -(-�, M RARP OI�I 010, 0D. �w ZL�� { PoLE RFLAY I SINDLE SRDT P m WM. P MLE WIO.I 0 0' O+�I lPov EOIL 1 n. DEUY IIPOV COIL a0A ,zOV COIL 21 C) 30A R-6 - R-7 R-S Email.-. 3 CONTL FWT n C[XiM R-. RELAY -_- l P f Q Oi'., Z> 3OA �o CONTACTOR PANEL-18"WX30"hX6"d PANEL LAYOUT NOTES: D AND DIRECTIONAL LIGHTS THROUGH 1. RUN MENUBOAR I H CONTACTOR PANEL. NOTE: T-STAT WIRING SHALL BE 18 AWG. 24V, 8 CONDUCTOR AIR COND. UNIT 1 AIR COND. UNIT 2 AIR COND. UNIT 3 " AIR COND.._, UNIT 4 PHOTO OPT I ONAL UNIT 5 CELL-1 L I GI HTS DRIVE THRU PARAPET LIGHTS MANSARD LIGHTS BLDG. LIGHTS SPARE ON/ OFF PANEL CONTACTOR & MOTOR STARTER ENCLOSURE FRYER --- EXHAUST FAN-2 -[7FAN-3 TSTAT REMOTE SENSOR REMOTE SENSOR / - TSTAT REMOTE SENSOR - TSTAT REMOTE SENSOR `— TSTAT REMOTE SENSOR _._._. _ TSTAT RFMOnR ANSUL SYSTEM FRYER CONTROL BRO� ILERI FAN-1 U BROILER CONTROL BURGER —KING SEQUENCE OF OPERATION MANUAL CONTROL SYSTEM THE A/C UNITS ON -OFF SWITCH IS USED TO: TURN THE STORE ON IN THE MORNING AND OFF IN THE EVENING. WHEN A/C UNIT ON -OFF SWITCH IS TURNED TO THE ON POSITION: THE AIR CONDITIONING SYSTEM WILL GO FROM NIGHT MODE TO SYSTEM ON. THE AIR CONDITIONING FANS WILL START AND RUN CONTINUOUSLY. THE OUTDOOR DAMPERS WILL OPEN TO A PRESET POSITION. (OPTIONAL) DAMPERS WILL NOT OPEN DURING NIGHT SET BACK MODE. (OPTIONAL) THE AIR CONDITIONERS WILL BEGIN TO COOL OR HEAT AT THE OCCUPIED TEMPERATURE SETPOINT. THE COOKING EQUIPMENT AND EXHAUST FANS CAN NOW BE TURNED ON WHEN NEEDED. WHEN A/C ON -OFF SWITCH IS TURNED TO THE OFF POSITION: EXHAUST FANS, SUPPLY FANS, AND EVAPORATOR BLOWERS WILL SHUT DOWN. THE HEATING AND COOLING OPERATION SHALL REVERT TO SYSTEM NIGHT SET BACK MODE. THE COOKING EQUIPMENT SHALL BE DISABLED. THE SIGNAGE LIGHTING & LOT LIGHTING SHALL BE DISABLED IF SWITCHES ARE IN THE OFF POSITION. THE PARKING LOT POLE LIGHTS & SECURITY LIGHTS SHALL REMAIN ON FOR 15 MIN AFTER THE SECURITY DEPARTURE SWITCH IS ACTIVATED. WHEN THE HOOD EXHAUST FAN CURRENT SENSOR DETECTS A DROP IN AMPERAGE IT WILL DISABLE THE LINE VOLTAGE TO THE FRYER AND BROILER APPLIANCES. HOOD VENTILATION SYSTEM IF THE HOOD VENTILATION SWITCH IS IN THE OPEN POSITION, THE HOOD VENTILATION SYSTEM CAN BE STARTED. THE BROILER SYSTEM AND THE FRYER SYSTEM SHALL BE STARTED BY MOVING THE ON/OFF SWITCH TO THE ON POSITION. IF EITHER THE BROILER OR FRYER SWITCH IS IN THE - ON POSITION, THE MAKE-UP AIR UNIT (IF APPLICABLE) SHALL START AUTOMATICALLY. ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM SHALL DE -ENERGIZE THE AIR CONDITIONING UNITS AND THE CONTROLLED COOKING EQUIPMENT AND SHUT OFF THE AUTO-SELENOID VALVE SUPPLYING THE COOKING EQUIPMENT. THE EXHAUST SYSTEM SHALL CONTINUE TO OPERATE AND THE FIRE SUPPRESSION SYSTEM SHALL BE MANUALLY RESET. EXTERIOR LIGHTING CONTROL ALL OF THE EXTERIOR LIGHTING SHALL BE CONTROLLED, WITH THE EXCEPTION OF THE SECURITY LIGHTS WHICH SHALL BE OPERATED BY ITS OWN PHOTOCELL,. SECURITY LIGHTING IS OPTIONAL. THE SIGNAGE SELECTOR SWITCH (3-POS.) CONTROLS THE PRIME SIGN, ALL MARQUEE SIGNS, AND BULUIDING ACCENT LIGHTING. ON POSITION: LIGHTING SHALL BE ON PERMANENTLY. OFF POSITION: LIGHTING SHALL BE OFF PERMANENTLY. AUTO POSITION: LIGHTING SHALL BE CONTROLLED BY THE PHOTO CELL. THE LOT LIGHTS THREE POSITION SWITCH WORKS THE SAME AS THE SIGNAGE SWITCH. NOTE: ON -OFF / MASTER RELAY PANEL SHALL BE COMPLETE WHEN SHIPPED TO THE JOB SITE. NO INTERNAL WIRING SHALL BE REQUIRED. MAKE ALL EXTERNAL WIRING CONNECTIONS AS REQUIRED. ��) Underwriters Laboratories, Inc. (4) LOT LIGHTS 11�22�17 (4) LOT LIGHTS 2813E41 ROBERT L. HINKLE PE 29302 POWELL & HINKLE ENGINEERING, P.A. 1409 KINGSLEY AVENUE, BLDG 12A P & H GALTON LANE R. C. MOK HINKLE PE 33192 ORANGE PARK, FLORIDA 32073 PE 48076 (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA. REG. EB-4577 THOMAS RICHARD DAVID R. M. ELDER A. MATHEWS SPELL JR. PE PE PE 56121 59418 54729 rvD 4.8D' a eS 101C R. Wulbern Y Architect PA AA - 0003433 IIC y(904)329.2510 i81 R O robert@wulbern.ne! R CL.c 00 0 N N C N CL C, c A O) c �o C 0) m N N :? > 50 Q, N c O ` N C C v_) (D 0) )- c ma) O m d m N 2 C 4) c � rn c N m _T �N I° ry C 0) 0 U N (D o N U m r � E c N L O w w a j w 0 N = m W U N Y CC 0 CD a a LU f Y Y Lu 0 LL 0 U. m m r` � r__ Q O O N 0 o 0 0 d rl > W K � F` m F- W) O < O O Fl, z W U Z Y LU — m = °` a of 0 L) OO 0 D_ [ I� goldco ..,,,.,:.. VERTIC L cm J t!) LO z N Q Q 2iN L . . w v Hco ZUCD Y o J co � Z� �� W = Y CO z W U O = O W LO ��� r0ff''�� rrl � J LM I II I rr W Z <0 J V U 10 N LIJ w H I W p LU U) U) O Z o 0 W POWER SOURCE FPPNL MICROSWITCH MANUAL RESET RELAY ELECTRIC GAS VALVE L JUNCTION BOXES J RESET POWER EXTERNAL WIRING BUTTON INDICATOR GND REDv LOAD GND A n B SCREN6 POWER GN H- (NEUTRAL) RELAY 4 N.O. CONTACT COIL 6 — 143 FIRE EXT. MICROSWITCH 9 COMMON CONTACTS 3 2 N.C. CONTACT 4 120V 60 HZ 7 i LOAD 1 10A MAX. RESISTIVE RESET RELAY 10A MAX. EXTERNAL CONTACT CLOSURE REQUIRED MANUAL RESET RELAY WIRING SCHEMATIC AMEREX AUTOMATIC FIRE CONTROL SYSTEM SCALE: NO SCALE NOTE 1 ROOF NOTE: PHONE COMPANY TO PROVIDE 10 PAIR CABLE MINIMUM. CIRCUIT A-28 MODEM 3/4„ E.C. 12"X12"X4" RECESSED MT'D. TEL, CAB. LOCATE AS MGR. OFF. DIRECTED BY B.K. FIELD OPT. SERV.1=PH; 2=FAX 4� 4C} RD. WITH TEL. LGAMEINES0 CNTR. DRIVE COMPANY (PLAYGRND) THRU FLOOR PROVIDE DUPLEX OUTLET ADJACENT TO TEL. CABINET TELEPHONE NOTE: (3) 2" E.C. RUN OUT AND PROVIDE NYLON PULLCORD TERMINATE AS DIRECTED BY IN EACH CONDUIT. TEL. CO. TELEPHONE RISER DIAGRAM SCALE: NO SCALE TELEPHONE RISER DIAGRAM NOTES* 1. FIELD VERIFY EXACT LOCATION WITH OWNER AND PROVIDE 3" PVC GOOSENECK THROUGH ROOF FOR I.T. DEPARTMENT. ALL ELECTRIC SERVICES TO KITCHEN EQUIPMENT SHALL BE OVERHEAD ROOF 4#6 & 1-#10 4#1 & 1-#8 GND. GND. IN 1" C. IN 1-1/2" C. MANUAL PANEL PANEL ON -OFF C- "D" "D2" PANEL L --J NpOO� L CONTROL WIRING STER OCONTROL PANEL �C 20A 20A NF NF 3-#4 & 1-#10 GND. WP WP IN 1" C. 2-#12 & 1-#12 GND. IN 1/2" C. REFERENCE WIRING DIAGRAM ON SHT. E4-1 L PANEL R A I WIRE TROUGH j (SIZE AS REQ'D) L----------------- LOCATED IN 4#1/0 & 1-#6 MGRS. OFFICE GND. IN 2" C. - REFERENCE SHT. E1-2 SEE NOTE 6 1#6 ISOLATED GND.IN 1/2"C.— PANEL „B" 3 3 360 3-#4 & 1-#10 GND. WP WP WP WP IN 1" C. 3-#4 & 1-#10 GND, IN 1" C. EXTERIOR BUILDING WALL TIME CLOCK FOR SPRINKLER SYSTEM LOCATE AT REAR WALL PANEL „M,, STRAP — Gr - 4#1/0 & 1-#6 GND. IN 2" C. # 2/0 (CU) i" C. 5/8"x10FT. COPPERCLAD GROUNDING RODS �� 6FT MIN. ELECTRICAL RISER DIAGRAM PROVIDE MAIN BREAKER SHUNT TRIP BREAK GLASS SWITCH (ASCO OR EQUAL)- WHEN REQUIRED BY LOCAL CODE- MOUNT W.P. SWITCH FLUSH IN OUTSIDE WALL AT METER LOCATION. u 1 1/2"C GENERAL ELECTRIC THYRITE CT ARRESTOR 3-POLE, 4-WIRE CAN 91_15BCCO03 OR WESTINGHOUSE VALVE TYPE ARRESTOR 634.A.217.A01 (INDOOR WITH W.P. BOX AND COVER) OR SQUARE D J-9200-9A (IF REQUIRED) LOCATE PER POWER CO. REQUIREMENTS #1 COPPER SOLID (GROUND) 2 SETS EACH;4-#350 (NO GROUND) IN 3"C WITH A 3' C SPARE (SERVICE TO MDP TO BE RUN UNDERGROUND) 1 R( I t--------------------------- METALLIC COLD WATER PIPE BLDG FOUNDATION STEEL SCALE: NOT TO SCALE ELECTRICAL RISER DIAGRAM NOTES: 1. PROVIDE MANUAL TRANSFER SWITCH (MTS), 208V/3PH/4-POLE (SWITCHED NEUTRAL), 600A S.E. RATED BREAKER FOR NORMAL POWER (N) AND 400A S.E. RATED BREAKER FOR EMERGENCY POWER (E). BREAKERS SHALL BE INTERLOCKED WITH A SINGLE KIRK KEY, IN A NEMA 3R ENCLOSURE. SQUARE-D CLASS 3140 OR EQUAL. 2. PROVIDE TAP BOX FOR CONNECTION OF PORTABLE GENERATOR. BOX SHALL CONTAIN 208V/3PH 400A LUGS BY POLARIS OR EQUAL, SUITABLE FOR CONNECTION TO GENERATOR LEADS. LUGS SHALL BE IDENTIFIED USING COLORED TAPE. BOX SHALL BE BY HOFFMAN OR EQUAL, NEMA 3R RATED AND SIZED AS REQUIRED FOR CONTENTS AND WIRING. COORDINATE EXACT REQUIREMENTS FOR TAP BOX WITH OWNER PRIOR TO WORK. GROUNDING OF PORTABLE GENERATOR SHALL BE PROVIDED BY CONNECTING TO THE BUILDING GROUNDING SYSTEM FROM WITHIN THE TAP BOX. r., HIGH VOLTAGE 13.2KV L-L �M 2-4"C STUB -UP ON POLE 4" ABOVE GRADE & CAP -OFF W/PULLWIRE 150KVA UTILITY COMPANY TRANSFORMER w, j ---------------------- 208V/ PH/4W o�'' r n J'.. I J w. MIN I I 1 — 42" J 1 1 1 1 PULLBOX (IF REQ'D BY UTILITY CO.) RISER NOTES: 1. ALL DISCONNECT SWITCHES TO BE PROVIDED BY CONTRACTOR. 2. REFER TO PANEL NOTES. 3. REFER TO GENERAL NOTES, ELECTRICAL POWER PLAN SHEET. 4. T.C.' INDICATES TIME CLOCK (OR TIME SWITCH) 5. SEE MASTER CONTACTOR PANEL WIRING DIAGRAM FOR ADDITIONAL CIRCUITS FROM PANELS THAT ARE CONTROLLED THROUGH THE MASTER CONTACTOR PANEL 6. PROVIDE AN ISOLATED GROUND BUS IN PANEL & RUN CIRCUIT GROUND WIRE TO THIS BUS. RUN A #6 GREEN GROUND FROM THIS BUS TO MAIN SERVICE GROUND POINT. 7. MASTER CONTACTOR PANEL AND MANUAL ON -OF PANEL TO BE INCLUDED IN ELECTRICAL CONTRACTORS SCOPE OF WORK. 11/22/17 2813E51 ROBERT L. HINKLE PE 29302 POWELL & HINKLE ENGINEERING, P.A. 1409 KINGSLEY AVENUE, BLDG 12A & H GALTON LANE R. C. MOK PE 33192 P ORANGE PARK, FLORIDA 32073 HINKLE PE 48076 (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA. REG. EB-4577 THOMAS RICHARD DAVID R. M. ELDER A. MATHEWS SPELL JR. PE PE PE 56121 59418 54729 R. Wulbern t Architect PA Q Oa AA-0003433 Ilc• N U (904) 329-2510 tel N U robed@wulbern.nel S� LJJ h !n z W Z 0cnu�a Y z Y Z Y �to a W w w a 0 LL 0 LL m m H Q O r O M d N 0 co 0 O r O O t d rl > w Y N m I c i O O O z NO w U Z 3 v w -) _ a 0 0 U O 0 a goldco a 6 u�9 •.v VERTIC°",L 00.. 0 V .J A.; cn N 6 m Z a �N rn .. w co 0 Z U Y o p Z� J LL W = �00::)5 LIJ U E-I = O �0(1'::)w °� Orrl o J M0ZE� IK ?" J r U_ LLI J ; W C J _H ♦— Q o Z rZ v J S 0 w w 2 In E5- 11 ELECTRICAL PANEL SCHEDULE PANEL: A SERVICE: 120/208V, 3P, 4W + GND FEEDERS: SEE ONE LINE DIAGRAM ER PANEL TYPE: j�PC�RORDNQODGNOINTETEDXC PWONSENTER SIZE: 150 AMP MLO MOUNTING: NEMA-1 RECESSED LOAD DESCRIPTION NOTE LOAD VOLT -AMP WIRE CB/P A 8 C CB/P WIRE LOAD VOLT -AMP NOTE LOAD DESCRIPTION FLAG POLE **** TC 69 12 20/1 1 '-- 220/1, 12 683 DINING RM. LIGHTS SPARE 20/1 3 4120/1 SPARE SPARE 20/1 51 I" ' 620/1, 12 399 KITCHEN AREA LIGHTS 7 8 20/1 12 1440 OCU / CREDIT CARD SWIPE AREA LIGHTS ** TC 576 10 20/1 9 I" 10 20/1 12 900 TC DIGITAL MENU BOARD ** TC 576 10 11 12j2O/1 12 480 RESTROOM LIGHTS/EF 2 DIRECTIONAL SIGNS ** TC 400 12 20/1 13 14120/1 12 627 KITCHEN/SERVICE/OFFICE LIGHTS DRIVE THRU MENU SIGNS ** TC 1440 12 20/115 420/1 12 720 RELAY PANEL PYLON SIGN ** TC 1 1200 12 20/117 18120/1 12 1 360 SMOKE DETECTOR ALARM PANEL CHANNEL LETTERS / LOGO ** TC 1200 12 20/119 20 20/1 12 300 SAFE CHANNEL LETTERS / LOGO ** TC 1200 12 20/1 21 ' _ 221120/1 SPARE CHANNEL LETTERS LOGO ** TC 1200 12 20 1 23 ' 24 20/1 12 900 OFFICE RECEPTACLES RED LED LIGHTS ** TC 240 12 20/1 25 ` 26 20/1 12 180 GFCI KITCHEN RECEPTACLES EXTERIOR BUILDING LIGHTS ** TC 1100 12 20/1 27 28 20/1 12 180 TELEPHONE REC. EXTERIOR BUILDING LIGHTS ** 1 TC 1270 12 20/1 29 301f 20/1 12 1260 GFCI DINING RECEPTACLES ROOF/EXTERIOR RECEPTACLES 720 12 20/1 31 32120/1 12 1700 GFCI ELECTRIC HAND DRYER - - SERVICE COUNTER/CORRIDOR 720 12 - 20/1 33 34 20/1 12 _ 1700 GFCI ELECTRIC HAND DRYER D/T SPEED/SERVICE #90C CAMERA 540 12 20/1 35 36,20/1, 12 1700 BACK DOOR AIR CURTAIN COOL/FRZR LIGHTS/DOOR HTR/HE. 380 12 20/1 37 1 36120/1, 12 1260 OFFICE RECEPTACLES CREW/STORAGE RECEPTACLES/WH 1 GFCI 820 12 20/1 39 - '' 40I 20/1, 12 1080 SERVICE COUNTER/MONITORS SPARE 20/1 41 4Z 20/1 _ SPARE TOTAL CONNECTED LOAD: 29,182 VA PHASE 'A': 9130 VA NOTES (TC) = WIRE THROUGH CONTACTOR. (HACR) = HACR TYPE BREAKER. TOTAL CONNECTED AMPS: 80.8 AMP PHASE 'B': 10,255.VA (LO) = LOCKED BREAKER 'A' 'C': (GFCI) = GROUND FAULT CIRCUIT INTERRUPTER PANEL NOTES: PHASE 9797 VA (IG) = WIRE SEPARATE TO ISOLATED GROUND BUS. 1, ** ELECTRICAL CONTRACTOR TO WIRE THESE CIRCUITS THRU MASTER CONTACTOR PANEL. REFERENCE WIRING DIAGRAMS ON MASTER CONTACTOR PANEL SHEET. 2. ALL BREAKERS SHALL BE RATED FOR SWITCHING DUTY. 3. * VERIFY CIRCUIT REQUIREMENTS FOR PYLON SIGN. 4. *** ZONES A & B ONLY. COORDINATE WITH HVAC. 5. **** CONNECT THROUGH PHOTOCELL ONLY. FLAG POLE SHALL ALWAYS BE ILLUMINATED WHEN DARKNESS IS DETECTED. ELECTRICAL PANEL SCHEDULE PANEL: B SERVICE: 120/208V, 3P, 4W + GND FEEDERS: SEE ONE LINE DIAGRAM PANEL TYPE: IPC�RORDNQODGNOTEXC PTIONSENTER SIZE: 150 AMP MLO MOUNTING: NEMA-1 RECESSED LOAD DESCRIPTION NOTE WIRE CB/P, A B C CB/P WIRE NOTE LOAD DESCRIPTION VOLT-AMP VOLT-AMP SELF -SERVE SODA DISPENSER 600 12 20/1 1 2120/1' 12 PA E P.O.S. RECEPTACLES GFCI o IG/LO/GFCI 540 12 26/1 3 4i120/1 12 1488 GFCI WATER BOOSTERS P.O.S. RECEPTACLES GFCI o IG/LO/GFCI 720 12 20/1 5 6 20/1 12 1320 GFCl/TC BROILER ** DRIVE-THRU SODA DISPENSER GFCI 636 12 20/1 7 8 120/1 12 7w GFCI CARBONATOR REAR DOOR BUZZER 720 12 20/1 9 1020/1, 12 I00 GFCI REACH -IN FREEZER DOOR ALARM/SECURITY SYSTEM 540 12 20/1 11 12 20/1 12 1320 GFCI FRY FREEZER/DISPENSER FROZEN COKE MACHINE 1872 12 20/2 13 14 20/1 8 1920 GFCl/TC MEAT FREEZER ** 1872 12 15 I 16 20/2 12 If 1664 FRY DUMP STATION (4) FRYER BANK ** GFCl/TC 1500 12 20/1 17 18 12 1664 (W/PRODUCT HOLDING CABINET) SPARE 20/119 I 20 20/2 12 if 1300 HACR ICE MACHINE COFFEE/TEA BREWER 1352 12 20/2 21 22 12 1300 1352 12 23, 24 20/1 12 ' 1300 HACR ICE MACHINE CONDENSER SHORTENING STORAGE UNIT 780 12 20/1 25, 2620/2 12 915 HACR BROILER HOOD FRYER HOOD LIGHTS/CONTROLS TC 1440 12 20/1 27 28 915 EF-2 BROILER HOOD LIGHTS/CONTROLS TC 1440 12 20/1 291 I' 30 20/2, 12 915 HACR FRYER HOOD DRIVE THRU COUNTER 360 12 20/1 311, 32 915 EF-1 SPARE 20/1 33� 34 20/1 SPARE SPARE 20/1 35 36 20/1 - - SPARE SPARE - 20/1 37' 3820/1 SPARE SPARE 20/2 39 1 40130/1 SPARE SPARE 20/2 41 - 42,20/1 SPARE TOTAL CONNECTED LOAD: 34,952 VA PHASE W: 11,110 VA NOTES (TC) = _ WIRE THROUGH CONTACTOR. (HACR) = HACR TYPE BREAKER. TOTAL CONNECTED AMPS: 96.8 AMP PHASE 'B': 12,071 VA (LO) = LOCKED BREAKER PANEL 'B' NOTES: PHASE 'C': 11,771 VA (GFCI) = (IG) = GROUND FAULT WIRE SEPARATE CIRCUIT TO ISOLATED INTERRUPTER GROUND BUS. 1. * PROVIDE ISOLATED GROUND BUS. 2. ** CONTRACTOR SHALL WIRE THESE CIRCUITS THRU MASTER CONTACTOR PANEL. REFERENCE WIRING DIAGRAM ON MASTER CONTACTOR PANEL SHEET. 3. ® PROVIDE HLO-1 HANDLE LOCK -OFF. 4. *** VERIFY OPTIONAL EQUIPMENT IS SELECTED OR LABEL CIRCUIT BREAKER AS SPARE. ELECTRICAL PANEL SCHEDULE PANEL: D (EQUIP. #21.75) SERVICE: 120/208/24OV, 3P, 4W + GNDFEEDERS: SEE ONE LINE DIAGRAM PANEL TYPE: SQ-D "NQOD", NO EXCEPTIONS SIZE: 150 MOUNTING: FURNISHED BY EQUIPMENT SUPPLIER LOAD DESCRIPTION NOTE VOLTOAAMP 1 WIRE CB/P A B C CB/P WIRE NOTE VOLT-AMP LOAD DESCRIPTION PRODUCT HOLDING UNIT 2X4 1487 12 20/2 1 I 2 20/2 12 1186 EGG STATION 1487 11 12 3 4 12 1186 PRODUCT HOLDING UNIT 3X4 1664 10 20/2 5 I' I" 6 30/2 10 1352 CONTINUOUS TOASTER 1664 10 7 8', 10 1352 SPARE '202 9 / 10 I 30/2 10 1352 CONTINUOUS TOASTER 11 12 10 1352 UTILITY OUTLET 180 12 ' 20/1 13 I' 14 20/1 _ SPARE SPARE 20/2 15 ' 16' H/1 12 1800 GFCI MICROWAVE 17 18 20/1 12 - 240 ,HEATED SURFACES SPARE 20/2 1 9 ' 20 H/1 'SPARE 21 ' 22, 20/1 12 1 900 GFCI BISCUIT HOLDING CAB SPARE 20/1 23 ' 24 20/1 12 600 EXPO SALAD STATION TOTAL CONNECTED LOAD: 17,802 VA PHASE 'A': 5,869 VA NOTES : (TC) = WIRE THROUGH CONTACTOR. TOTAL CONNECTED AMPS: 49.3 AMP PHASE 'B': 6,725 VA (HACR) = (LO) =LOCKED HACR TYPE BREAKER. BREAKER PHASE 'C': 5,208 VA (GFCI) = GROUND FAULT CIRCUIT INTERRUPTOR (IG) = WIRE SEPARATE TO ISOLATED GROUND BUS. NOTE: ALL RECEPTACLES TIED TO PANEL 'D' TO BE GFCI. ELECTRICAL PANEL SCHEDULE PANEL: M A.I.C. RATING: 25,000 SERVICE: 120/208V, 3P, 4W + GND FEEDERS: SEE ONE LINE DIAGRAM PANEL TYPE: �IPC�RORDI -LINE RNOEEEXCEEPTIONSENTER SIZE: 600 AMP MLO *** MOUNTING: NEMA-1 RECESSED LOAD DESCRIPTION NOTE WIRE CB/PI AB C CB/P',I WIRE LOAD DESCRIPTION VOLOAAMP VOLTOAD -AMPNOTE - - 9130 #1/0 i150/3 1__ 2 150/3 #1/0 11,110 --- - -- PANEL A 10255 I - 12,071 PANEL B 9797 11,771 3 4 150/3 #1/0 5,869 SPACE ONLY I 6,725 PANEL D 5,208 HACR ** RTU-1 5901 #4 70/3 5 ( 6 50/31 #6 3,848 5901 I" _. 3,848 PANEL D2 5901 l >' 180 HACR ** 5901 #4 70/3 7 8'30/3 #10 2300 _ RTU-2 5901 1" 2300 COMBI OVEN -STEAMER 5901 2300 HACR ** RTU-3 4649 #4 50/3 9 `10 20/21 #12 1 465 WALK-IN BOX COOLER 4649 �' 465 CONDENSER 4649 SPACE ONLY HACR ** 4649 #4 50/3 11 1 1 12, 20/2l #12 971 COMBO SHAKE MACHINE RTU-4 4649 - ( 971 SOFTSERVE 4649 971 WALK-IN BOX FREEZER 3024 #10 30/3 13 14 20/2 #12 1040 COMBO SHAKE MACHINE CONDENSER 3024 ( 1040 FROZEN 3024 1040 TOTAL CONNECTED LOAD: 177,124 VA PHASE 'A': 59,216 VA NOTES: (TC) = WIRE THROUGH CONTACTOR. 'B': (LO) HACR) = HACR TYPE BREAKER. TOTAL CONNECTED AMPS: 490.6 AMPS PHASE 62,158 VA = LOCKED BREAKER PHASE 'C': 55,750 VA (GFCI) = GROUND FAULT CIRCUIT INTERRUPTOR PANEL 'M' NOTES: (IG) = WIRE SEPARATE TO ISOLATED GROUND BUS. 1. * VERIFY IF OPTIONAL ELECTRIC FRYERS IS SELECTED. PROVIDE RECEPTACLES AND CIRCUIT RUNS AT FRYERS TO PANEL-C AND WIRED THROUGH MASTER CONTROL PANEL. REMOVE BREAKER FOR FRYERS #31 IN PANEL-B, AND REMOVE GAS PIPING RUNS FROM PLANS AND ADJUST LOAD. SEE LOAD SUMMARY FOR UPDATED SERVICE SIZING AND ADJUST PANEL-M & SERVICE SIZE AS REQUIRED. 2. ** VERIFY MANUFACTURERS NAMEPLATE DATA AND PROVIDE WIRE/BREAKER SIZE AS REQUIRED. 3. *** MDP SHALL BE PROTECTED BY A BREAKER IN THE MANUAL TRANSFER SWITCH. ELECTRICAL PANEL SCHEDULE PANEL: D2 (EQUIP. #21.57) SERVICE: 120/208/24OV, 3P, 4W + GNDFEEDERS: SEE ONE LINE DIAGRAM PANEL TYPE: SQ-D "NQCI NO EXCEPTIONS SIZE: 50 MOUNTING: FURNISHED BY EQUIPMENT SUPPLIER LOAD DESCRIPTION NOTE VOLT -AMP WIRE ICB/P A B C CEI WIRE VOLT -AMP NOTE LOAD DESCRIPTION U.C. REFRIGERATOR 1920 1 12 20/1 1 2 20/1 SPARE SPARE j 3 4 20/1 SPARE EXPEDITER STATION GFCI 180 12 20/11 6 20/1 SPARE TOTAL CONNECTED LOAD: 7,876 VA PHASE 'A': 3848 VA NOTES :: (TC) = WIRE THROUGH CONTACTOR. TOTAL CONNECTED AMPS: 21.8 AMP PHASE 'B': 3848 VA (HACR) (LO) = HACR TYPE BREAKER. =LOCKED .BREAKER PHASE 'C': 180 VA (GFCI) = GROUND FAULT CIRCUIT INTERRUPTOR (IG) = WIRE SEPARATE TO ISOLATED GROUND BUS. NOTE: ALL RECEPTACLES TIED TO PANEL 'D2' TO BE GFCI. LOAD SUMMARY KITCHEN LOADS A 0 B 28,412 C 0 D 18,762 M 14,010 TOTAL 61,184 X 65% = 39,770 LIGHTING LOADS A 11,668 B 0 C 0 D 0 M 0 TOTAL 11,668 X 125% = 14,585 REMAINING LOADS A 16,587 B 4,920 C 0 D 0 M 73,320 TOTAL 94,827 X 100% = 94,827 TOTAL ADJUSTED LOAD = 149,182 VA 413.2 AMPS x 1.25% = 516.6 AMPS SERVICE SIZED AT 600 AMPS ELECTRICAL DISTRIBUTION PANELS, MASTER CONTACTOR PANEL AND MANUAL ON/OFF PANEL MAY BE PURCHASED AS A LOOSE GEAR PACKAGE THROUGH: SUNCOAST ENVIRONMENTAL CONTROLS, INC. 8566 115TH AVENUE NORTH LARGO, FLORIDA 34643 PHONE (877) 544 6679 1/10/18 2813E52 ROBERT L. HINKLE PE 29302 POWELL & HINKLE ENGINEERING, P.A. 1409 KINGSLEY AVENUE, BLDG 12A GALTON C. MOIL PE 33192 �& H ORANGE PARK, FLORIDA 32073 LANE R. HINKLh; PE 48076 (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA. REG. EB-4577 THOMAS RICHARD DAVID R. M. ELDER A. MATHEWS SPELL, JR. PE PE PE 56121 59418 54729 R. Wulbern Architect PA ..- a AA-0003433 Ile• O O W U (904(329-2510 tel. N U robert@wulbern.net O Cm U � m LL w z o Q W Z U W W 0 m m 0 LL � W H Q m O O V N 0 0 0 a _ > W N m H to O a o A. o 1 z U �O Z 3 t W It _ �` Q x o v o goldco w b tl dnB w. VERTIC�` L V J cn � N z Q �N rn Hcy) Z U Y 0 Z� ILL Li C C) Z) WUFi=° V W �� °Z) = 0F� rTl 00 J W0 Z CCOu 7w C GI Q Q co LU J Z U w � _ Lu J w J F_ Lu o Z 0 p H H- W W x W E51111111111111,2 Q1 4" GREASE WASTE TO TWO (2) 1,250 GALLON IN -LINE GREASE L INTERCEPTORS. SEE CIVIL DRAWINGS FOR INTERCEPTOR LOCATION, DETAILS AND CALCULATIONS.. 2Q GAS REGULATOR, ME ER ASSEMBLY AND GA PIPING PROVIDED AND INSTALLED BY GAS UTILITY COMPANY. SEE CIVIL DWG'S FOR LOCATION AND ADDITIONAL INFORMATION. Q3 GAS FIRED WATER HEATER MOUNTED ON WALL. PROVIDE WITH CONCENTRIC EXHAUST TO ROOF. ® 1-1/4" GAS PIPING DOWN TO WATER HEATER. Q5 GAS SOLENOID VALVE, INTERLOCK WITH HOOD FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA. VALVE, SHALL BE FURNISHED BY HOOD FIRE PROTECTION SYSTEM MANUFACTURER AND INSTALLED BY PLUMBING CONTRACTOR. Q CONNECT TO KITCHEN EQUIPMENT. PROVIDE WITH GAS PRESSURE REGULATOR & DIRT LEG AS REQUIRED. VERIFY GAS PRESSURE AND CONNECTION REQUIREMENTS WITH EQUIPMENT MANUFACTURER. Q 1-1/2" MANUAL GAS SHUTOFF VALVE LOCATED AT 60" A.F.F. Q 3" HUB DRAIN WITH 4x3 REDUCER, HUB STRAINER AND 4" DEEP SEAL TRAP. Q TERMINATE 1-1/4" CONDENSATE DRAIN(S) AT MOP SINK. 10 3/4"CW UP TO ROOF FOR POST HYDRANT. SEE PLUMBING ROOF PLAN ON SHEET P1-2 FOR CONTINUATION. 1 3/4" CW DOWN TO HB-1. 102 CAST IRON VALVE BOX WITH COVER FLUSH WITH FINISHED GRADE. 13 2" CW MAIN RISE TO ABOVE CEILING. PROVIDE SHUT-OFF VALVE ABOVE REMOVABLE CEILING TILE. 14 TERMINATE DRAIN FROM COMBI OVEN STEAMER AT FLOOR SINK. 5 TERMINATE DRAIN FROM ICE MACHINE AND STORAGE BEN AT HUB DRAIN. GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. GENERAL CONTRACTOR AND PLUMBING CONTRACTOR SHALL VERIFY GAS REQUIREMENTS OF THIS PROJECT BEFORE BIDDING AND PROCEEDING WITH WORK. 3. ALL HOT AND COLD WATER PIPING LOCATED ABOVE CEILING AREAS, BUT BELOW ROOF INSULATION, SHALL BE INSULATED WITH 1" FIBERGLASS LOW-PRESSURE TYPE WITH DUAL -TEMPERATURE JACKET. ALL HOT AND COLD WATER PIPING LOCATED OUTSIDE OF BUILDING INSULATION ENVELOPE SHALL BE INSULATED WITH A WATER RESISTANT JACKET AND MEET NECESSARY ENERGY CODE REQUIREMENTS. 4. LOCATE COLD & HOT WATER PIPES IN FURRED -OUT SPACES AND DOWN THRU WALLS. 5. PROVIDE FROST -PROOF WALL HYDRANTS. 6. PROVIDE SEPARATE SHUT-OFF VALVES FOR ALL EQUIPMENT REQUIRING WATER CONNECTIONS. 7. PROVIDE COUPLINGS TO ALL EQUIPMENT CONNECTIONS AS REQUIRED. 8. PROVIDE 1/4" DIAMETER AIR LINE ABLE TO WITHSTAND 50# PRE55URE, TO RUN OVERHEAD FROM SODA FACTORY DOWN TO TAYLOR SHAKE MACHINE. (WHERE APPLICABLE) FS-1 I ---- -- L----- I K, -PIPED W/HOOD. UNION AND CONN. NE AT TOP OF HOOD. kNO PLU 1NG/PIPING TO BE I 4 - If 1N HOOD AREA. _.... . - - . _ . E-1 �e�W 15 �13 2 —1 Ii -7 'H-1 F-4 ,I li v 3'VTR 4 I _ "GI SEE 1 CIVIL DRAWINGS FOR 6 NOT USED. 7 NOT USED. 18 3/4" CW & HW DOWN TO BELOW GRADE. PROVIDE SHUT-OFF VALVE TO ISOLATE WATER TO TRASH ENCLOSURE AREA. 19 3/4" CW & HW ROUTED TO F-8 LOCATED AT TRASH ENCLOSUF AREA. Q WATER HEATER CONCENTRIC VENT. ROUTE WATER HEATER CONCENTRIC VENT TO THIS LOCATION TO MAINTAIN MINIMUM 10' CLEARANCE FROM HVAC FRESH AIR INTAKE. PLUMBING FLOOR PLAN SCALE: 1/4" = 1'-O" 9. PLUMBING CONTRACTOR TO FURNISH AND INSTALL MECHANICAL GAS SHUT-OFF VALVES FOR FIRE PROTECTION SYSTEM. 10. PROVIDE BACKFLOW PREVENTOR ON WATER LINES WHERE REQUIRED BY LOCAL CODES. 11. PROVIDE SUPPORTS AS REQUIRED FOR FIXTURES AND PIPING. 12. PLUMBING CONTR. TO COORDINATE VENT STACKS WITH OUTSIDE AIR INTAKES OF A/C UNITS AND SUPPLY FANS & MAINTAIN AT LEAST 10'-0" MIN. CLEARANCE OR AS PER LOCAL CODE REQUIREMENTS. 13. PROVIDE 2" COPPER SAFEWASTE LINE FROM SODA FACTORY TO FLOOR DRAINS/SINKS. 14. RUN SYRUP LINES FROM SODA FACTORY TO DRINK DISPENSERS ABOVE CEILING, 15. PROVIDE SAFEWASTE LINE FOR HOT CHOCOLATE, COFFEE AND TEA DISPENSER IF REQ'D 16. PROVIDE CONDENSATE LINES FROM A/C UNITS ABOVE CEILING ACCORDING TO LOCAL CODE REQUIREMENTS. 16a. PROVIDE CONDENSATE LINES FROM ROOF TOP A/C UNITS ABOVE ROOF ACCORDING TO LOCAL CODE REQUIREMENTS. 17. RESEAL FLOOR DRAINS ACCORDING TO LOCAL REQUIREMENTS. 18, SAFEWASTE PIPING ABOVE AND ALONG FLOOR SHALL BE SIZED IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. 19. COORDINATE SAFEWASTE LINE CONNECTIONS WITH EQUIPMENT ROUGH -IN. 20: P.V.C. (SCHEDULE 40) PIPE CAN BE USED FOR VENTS AND WASTE ONLY IF APPROVED BY LOCAL BUILDING CODES. SEE SPECS. FOR ADD'L. INFO. (PVC NOT ALLOWED IF RUN IN AIR PLENUM). 21. COORDINATE LOCATION OF FLOOR DRAINS AND FLOOR SINKS WITH KITCHEN EQUIPMENT VENDOR DRAWINGS. 22. IF WALK -IN -BOX CONDENSATE LINE IS REQUIRED BY LOCAL CODE, PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL 1-1/4" CONDENSATE LINE, AND SEAL AROUND ALL PENETRATIONS THROUGH THE WALK -IN -BOX. 23. HEAT TAPE IS PROVIDED BY WALK -IN -BOX MANUFACTURER AND INSTALLED BY ELECTRICAL CONTRACTOR. IT IS TO BE SELF-LIMITING TYPE, "FROSTEX" OR EQUAL. 24. COORDINATE LOCATION OF HOSE BIB/IRRIGATION SYSTEM W/ LANDSCAPE DWG'S• 25, ALL EXPOSED WATER SUPPLY PIPING SHALL BE COPPER WITH PLASTIC ESCUTCHEON PLATES. 26. PROVIDE STAINLESS STEEL FASTENERS AT ALL EXPOSED LOCATIONS IN KITCHEN AREA, 27. ALL COVER PLATES IN TOILET ROOMS SHALL BE STAINLESS STEEL. � �Fa i � W . NV. ELEV. -2.75t No SEE CIVIL DRAWINGS - FON CONTINUATION. PROVIDE ISOLATING FLANGE ABOVE GRADE BEFORE ENTERING —OBUILDING. SEE CIVIL DRAWINGS FOR CONTINUATION. 1-1/2"G (574MBH) PRESSURE i44INV. ELEV. -3 00f SEE CIVIL DRAWINGS CO-2 FOR 6ONTINUAT10N I rCONTRACTOR TO VERIFY, CONFIRM AND COORDINATE WITH GENERAL CONTRACTOR, HVAC CONTRACTOR, KITCHEN EQUIPMENT SUPPLIER AND I UTILITY COMPANY TO DETERMINE THE (TYPE OF FUEL SUPPLY, CONNECTING PIPE SIZE, LOCATION AND OTHER I REQUIREMENTS REQUIRED FOR THE PROPER AND SAFE OPERATION OF LTHE EQUIPMENT.' — — — — — — J F----------------� SEE RISER DIAGRAMS FOR ADDITIONAL PIPE SIZES L---------------J BUILDING GAS DEMAND FIXTURE CONN. MBH QTY. EACH MBHEACH ALL BROILER 3/4" 75 1 75 WATER HEATER 1-1/4" 199 1 199 RTU-1 - - - - RTU-2 RTU-3 RTU-4 - - - _ GAS FRYER 3/4" 75 2 150 GAS FRYER 3/4" 75 2 150 TOTAL 574 REQ'D. PIPE SIZE 1-1/2" SYSTEM SIZED FOR GAS PRESSURES OF LESS THAN 2 PSI AND A PRESSURE DROP OF 0.5 INCH OF WATER COLUMN PER TABLE 402.4(2) OF THE 2010 FLORIDA FUEL GAS CODE. GAS PIPE SIZED FOR A TOTAL DEVELOPED LENGTH (TDL) OF 100'. MBH RATING FOR EQUIPMENT IS DETERMINED BY THE MANUFACTURER. .SYSTEM DESIGN AND INSTALLATION IS FOR NATURAL GAS. *CONNECTION SIZES SHALL BE DETERMINED FROM MANUFACTURERS RECOMENDATION. ROBERT L, HINKLE PE 29302 POWELL & HINKLE ENGINEERING, P.A. 1409 KINGSLEY AVENUE, BLDG 12A P & H GALTON C. MOK PE 33192 ORANGE PARK, FLORIDA 32073 LANE R. HINKLE PE 48076 (904) 264-5570 FAX:(904) 278-2646 GINEERING CORPORATION FLA. REG. EB-4577 THOMAS RICHARD DAVID R. M. ELDER A. MATHEWS SPELL JR. PE PE PE 56121 59418 54729 R. Wulbern t Architect PA Q 0 AA - 0003433 Ilc y U (904)329-2510 tel ? U robert@wulbern.nel Z z o In W U Y Y 0 a 0 m m LL Oa w H o o o 0 0 i 0 d rl in a` o O Z w U Z Y $ w x a w 0 V 0 CL goldco VERTIC L O V J cy) cl� Z Q N Lli It O ZUo Yo Z_� ' o W=> viz WUF-4=° � w =0 W O) M( r� r��j � J W �J F-t m U) (kill G� z� mo< o Z J Z J L.L w J F- o 0 q H H w w N Pi m,,l 1 2. GENERAL NOTES: DO NOT SCALE DRAWINGS. GENERAL CONTRACTOR AND PLUMBING CONTRACTOR SHALL VERIFY GAS REQUIREMENTS OF THIS PROJECT BEFORE BIDDING AND PROCEEDING WITH WORK. 3. ALL HOT AND COLD WATER PIPING LOCATED ABOVE CEILING AREAS, BUT BELOW ROOF INSULATION, SHALL BE INSULATED WITH 1" FIBERGLASS LOW-PRESSURE TYPE WITH DUAL -TEMPERATURE JACKET. ALL HOT AND COLD WATER PIPING LOCATED OUTSIDE OF BUILDING INSULATION ENVELOPE SHALL BE INSULATED WITH A WATER RESISTANT JACKET AND MEET NECESSARY ENERGY CODE REQUIREMENTS. 4. LOCATE COLD & HOT WATER PIPES IN FURRED -OUT SPACES AND DOWN THRU WALLS. 5. PROVIDE FROST -PROOF WALL HYDRANTS. 6. PROVIDE SEPARATE SHUT-OFF VALVES FOR ALL EQUIPMENT REQUIRING WATER CONNECTIONS. 7. PROVIDE COUPLINGS TO ALL EQUIPMENT CONNECTIONS AS REQUIRED. 8. PROVIDE 1/4" DIAMETER AIR LINE ABLE TO WITHSTAND 50# PRESSURE, TO RUN OVERHEAD FROM SODA FACTORY DOWN TO TAYLOR SHAKE MACHINE. (WHERE APPLICABLE) I I I I I II I 9. PLUMBING CONTRACTOR TO FURNISH AND INSTALL MECHANICAL GAS SHUT-OFF VALVES FOR FIRE PROTECTION SYSTEM. 10. PROVIDE BACKFLOW PREVENTOR ON WATER LINES WHERE REQUIRED BY LOCAL CODES. 11. PROVIDE SUPPORTS AS REQUIRED FOR FIXTURES AND PIPING. 12. PLUMBING CONTR. TO COORDINATE VENT STACKS WITH OUTSIDE AIR INTAKES OF A/C UNITS AND SUPPLY FANS & MAINTAIN AT LEAST W-0" MIN. CLEARANCE OR AS PER LOCAL CODE REQUIREMENTS. 13. PROVIDE 2" COPPER SAFEWASTE LINE FROM SODA FACTORY TO FLOOR DRAINS/SINKS: 14. RUN SYRUP LINES FROM SODA FACTORY TO DRINK DISPENSERS ABOVE CEILING. 15. PROVIDE SAFEWASTE LINE FOR HOT CHOCOLATE, COFFEE AND TEA DISPENSER IF REQ'D. 16. PROVIDE CONDENSATE LINES FROM A/C UNITS ABOVE CEILING ACCORDING TO LOCAL CODE REQUIREMENTS. 16c. PROVIDE CONDENSATE LINES FROM ROOF TOP A/C UNITS ABOVE ROOF ACCORDING TO LOCAL CODE REQUIREMENTS. 17. RESEAL FLOOR DRAINS ACCORDING TO LOCAL REQUIREMENTS. ---------------- ADDITIONAL DETAILS. _-_-------------------------J Q 3/4"CW SUPPLY UP FROM BELOW. SEE PLUMBING FLOOR PLAN ON SHEET P1-1 FOR CONTINUATION. IF----------- CONTRACTOR TO VERIFY, CONFIRM AND COORDINATE WITH GENERAL CONTRACTOR, HVAC CONTRACTOR, KITCHEN EQUIPMENT SUPPLIER AND UTILITY COMPANY TO DETERMINE THE TYPE OF FUEL SUPPLY, CONNECTING PIPE SIZE, LOCATION AND OTHER (REQUIREMENTS REQUIRED FOR THE PROPER AND SAFE OPERATION OF LTHE EQUIPMENT. _ _ _ _ _ _ J PLUMBING ROOF PLAN SCALE: 1 /4" = 1'-O" 18. SAFEWASTE PIPING ABOVE AND ALONG FLOOR SHALL BE SIZED IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. 19. COORDINATE SAFEWASTE LINE CONNECTIONS WITH EQUIPMENT ROUGH -IN. 20. P.V.C. (SCHEDULE 40) PIPE CAN BE USED FOR VENTS AND WASTE ONLY IF APPROVED BY LOCAL BUILDING CODES. SEE SPECS. FOR ADD'L. INFO. (PVC NOT ALLOWED IF RUN IN AIR PLENUM). 21. COORDINATE LOCATION OF FLOOR DRAINS AND FLOOR SINKS WITH KITCHEN EQUIPMENT VENDOR DRAWINGS. 22. IF WALK -IN -BOX CONDENSATE LINE IS REQUIRED BY LOCAL CODE, PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL 1-1/4' CONDENSATE LINE, AND SEAL AROUND ALL PENETRATIONS THROUGH THE WALK -IN -BOX. 23. HEAT TAPE IS PROVIDED BY WALK -IN -BOX MANUFACTURER AND INSTALLED BY ELECTRICAL CONTRACTOR. IT IS TO BE SELF-LIMITING TYPE, "FROSTEX" OR EQUAL. 24. COORDINATE LOCATION OF HOSE BIB/IRRIGATION SYSTEM W/ LANDSCAPE DWG'S. 25. ALL EXPOSED WATER SUPPLY PIPING SHALL BE COPPER WITH PLASTIC ESCUTCHEON PLATES. 26. PROVIDE STAINLESS STEEL FASTENERS AT ALL EXPOSED LOCATIONS IN KITCHEN AREA. 27. ALL COVER PLATES IN TOILET ROOMS SHALL BE STAINLESS STEEL. --——— — — — — II II I I I I I POWELL & HINKLE ENGINEERING, P.A. ROBERT L. HINKLE PE 29302 1409 KINGSLEY AVENUE, BLDG 12A GALTON C. MOK PE 33192 P & H ORANGE PARK, FLORIDA 32073 LANE R. HINKLE PE 48076 (904) 264-5570 FAX:(904) 278-2646 THOMAS M. ELDER PE 56121 'GINEERING CORPORATION FLA. REG. EB-4577 RICHARD A. MATHEWS PE 59418 DAVID R. SPELL JR. PE 54729 R. Wulbern r 'j Architect PA O O AA • 0003433 Ilc . w U (904)329.2510 tel . 0) 2 robert@}wulbern.net. d 'c 8 2 9-0 m c � m c 0 �d rn »_ N a) 'v ID N o d °c rn �Y ca C m m d N Z z 0 Y2=a� cg o W U Y Y n/ m m LL u- W Q O O M N 0 0 0 d _ m 2 rl xrl N r, C) O O z W U z Y W — fe S Q w o u O o a w U) D w m 0 Z a 0 Z Q Q z w w a z Z 0 0 A CJOIdco VERTIC L O U cu J N Lo N z Q ¢ N CY 0) W V O ZU Y 0 Z� LL �Lu 0H=o �c) j W = CC) 0 m3 z (lop ou In � L r xU) v ZLL m Q Q' D LL a_ J w J H 0 Z 0 o w w W Pl -2 3"VTR J L MI I \ / \2'• F-1 / CO-1 CO-2 I \ / T 3., I F-3 I cV FD-1 I F-2 I IN FD-1 I CO -'I I 3\— FS_-1 qU' ( E-1 HANI SINK 2"VTR J L I N I I Is " \ I E SODA \ C \ L FOUNTAIN TP-1 \ \ E-1 E-1 " \ . HAND Y-�Q FROZEN xll \\ SINK \ MACOKE CHINE HB-1 \ \ \ \ 7 10. \ \ \ 1 � /2'• � SP BH FILTER � \ �j4\ `FAO• E-1 E-1 I E-1 PREP \ P P SP./ SINK �� �\ I 5'P/ �/2•,\ 1 I TP-1�/ TT\ / F-3 I\ 5.P 1,1I 1 I�>_1 TP ' IF-3 I F-2 TP-1 / E-1 I I TP-1I v'�0 / / / SIN J D I II / .I �F-1 \ / FIL IER SYSTEM -I� NI NCI HB--1'IJj VALVE BOX WITH • COVER FLUSH WITH `a FINISHED GRADE SEE CIVIL DWG FOR CONT. Q 4" GREASE WASTE TO GREASE INTERCEPTOR. SEE CIVIL DRAWINGS FOR LOCATION AND INTERCEPTOR DETAILS. Q 3" HUB DRAIN WITH 43 REDUCER, HUB STRAINER AND 4" DEEP SEAL TRAP. Q 1/2" TRAP PRIMER LINE TO TRAP PRIMER. SANITARY RISER NOT TO SCALE SEE CIVIL DWG FOR CONT. 3`V1R JIL i I I "I I I E-1 l HAND -T SINK FS-1 4 o Q GAS REGULATOR, METER ASSEMBLY AND GAS PIPING TO L.P. TANK PROVIDED AND INSTALLED BY GAS UTILITY COMPANY. LOCATE TANK MIN 10' FROM EDGE OF BUILDING OR SOURCE OF COMBUSTION. SEE CIVIL DWG'S FOR LOCATION AND ADDITIONAL INFORMATION. O GAS PRESSURE TO BUILDING IS 2 PSI. PROVIDE REGULATOR TO STEP PRESSURE DOWN TO 10" W.C. INSIDE BUILDING. Q 1-1/4" GAS PIPING TO WATER HEATER. PROVIDE WITH GAS PRESSURE REGULATOR & DRIP LEG AS REQUIRED. VERIFY GAS PRESSURE AND CONNECTION REQUIREMENTS WITH EQUIPMENT MANUFACTURER. E-1 GAS FRYERS (4 TYP.) HOLD GAS VALVE.16" \, ® MINIMUM FROM HOOD 5 �� •2�' j./�'� E-1 5 P 6 GAS BROILER U P -1 VEN =AMER It o M \ MI I �\ J �HB-1 E 1 E-1 3-COMP 30NATOR SINK 3 I I F-8 N\ AT I IM TRASH I ENCLOSURE � ' /2"G I (574 MBH) BELOW -� 6 GRADE I O� SEE CIVIL DWG FOR CONT. ® GAS SOLENOID VALVE, INTERLOCK WITH HOOD FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA. VALVE SHALL BE FURNISHED BY HOOD FIRE PROTECTION SYSTEM MANUFACTURER AND INSTALLED BY PLUMBING CONTRACTOR. Q CONNECT TO KITCHEN EQUIPMENT. PROVIDE WITH GAS PRESSURE REGULATOR & DRIP LEG AS REQUIRED. VERIFY GAS PRESSURE AND CONNECTION REQUIREMENTS WITH EQUIPMENT MANUFACTURER. © MANUAL SHUTOFF VALVE LOCATED AT 60" A.F.F. Q7 1/2" TRAP PRIMER LINE TO FLOOR DRAIN. ® 3/4" 120-HW, 1" 140'HW AND 1-1/4"CW TO WATER HEATER AND MIXING VALVE. SEE WATER HEATER DETAIL FOR ADDITIONAL INFORMATION. DOMESTIC WATER & GAS RISER NOT TO SCALE POWELL & HINKLE ENGINEERING, P.A. ROBERT L. HINKLE PE 29302 1409 KINGSLEY AVENUE, BLDG 12A GALTON C. MOK PE 33192 P & H ORANGE PARK, FLORIDA 32073 LANE R. HINKLE PE 48076 (904) 264-5570 FAX:(904) 278-2646 THOMAS M. ELDER PE 56121 ENGINEERING CORPORATION FLA. REG. EB-4577 RICHARD A. MATHEWS PE 59418 DAVID R. SPELL JR. PE 54729 R. Wulbern ui Architect PA AA • 0003433 Ile y �U (904)329.2510 tel 'a' N U robertQmlbern.net c U 2 c o (L` c m c ` o c d me N N rn5 b,5 � N c a)0 � N � L C 0 N N � N N � d co c � .y c rn =d o .o c � U a� d t � E c E N U I-- T N Z Lu itLLi C7 O O m m LL LL w ` n r a rn i m y 4 ^ a _ m F �^ 2 2 J < N3 O 0 o z W U a Lu °`a0 o U Oo IL 0 w x U) z U. LL J Q U LL w a to co x U 0 O LL x z r- ui w x 0 w 0 a rr a Lu w z 0 0 z z a 0 LL a z cr 0 w J O _ z 0 w U O O _ a w of 0 z a 0 w U) Z) w m 0 z Q 0 J Q (q�) z V w 0 0 LL z 0 U U) z 0 w w w w Z Q z u z 0 U F- z W O W co 0 LL z 0 P2,,,m, 1 w x .EANOUT AINLESS OVER PLATE SEE PLAN AND DIAGRAM FOR PIPE SIZE DETAIL - WALL CLEANOUT NOT TO SCALE HEAVY-DUTY SCORIATED COVER WITH "CO" CAST IN FINISHED FLOOR e 8..a GASKETED ABS CLEANOUT PLUG ADJUSTABLE HOUSING SPIGOT OUTLET DETAIL - ONE-WAY FLOOR CLEANOUT NOT TO SCALE HEAVY-DUTY SCORIATED 1211x12"X4" THICK / COVER WITH "CO" CAST IN CONCRETE PAD / FINISHED GRADE GASKETED ABS CLEANOUT PLUG ADJUSTABLE DETAIL - 2-WAY CLEANOUT ON GRADE NOT TO SCALE DRAIN LINE FLOOR GRATE I_ - MOUNT FLUSH WITH FLOOR A1R GAP=2xY' poo vv p v 0 o � o° o vv . .° O HUB OUTLET LIFT OUT ALUMINUM SEDIMENT BUCKET FLOOR SINK DETAIL NOT TO SCALE SEAL PER ALL EXTERIOR APPLICABLE CODE WALL REQUIREMENTS. SEE PLAN FOR CONT. TERMINATE SLEEVE 1/2" ABOVE FINISHED FLOOR. FLOOR PVC SLEEVE GRADE BEAM (UNLESS OTHERWISE SPECIFIED). WATER SERVICE TO BUILDING DETAIL - WATER SERVICE ENTRANCE NOT TO SCALE �1/2" TRAP PRIMER SUPPLY rtt�/ e- "rDOMESTIC WATER LINE SLEEVE THRU SLAB DETAIL - TRAP PRIMER NOT TO SCALE DRAIN SUPPORT STRAP TRAP PRIMER VALVE iI�� ROOF TYPICAL PIPE SUPPORT GAS PIPE REFER TO ANCHORED TO DECK SUPPORTED DETAIL PIPE WITHOUT JOINTS TDO NOT INSTALL V LVES ----- --- IN CEILING SPACE EXHAUST HOOD 1 _ 1 rrl1,HL rlrc aurrun i ANCHORED TO WALL L____________ GAS PIPE HEADER ALONG WALL BEHIND _ MANUAL GAS VALVE COOKING EQUIPMENT, APPROXIMATELY I GAS SHUT- OFF VALVE. PROVIDED 12" ABOVE FLOOR, WITH SCREWED I BY HOOD FIRE PROTECTION SYSTEM FITTINGS, SIZE AS SHOWN ON PLANS. MANUFACTURER, INSTALLED BY P.C. PROVIDE QUANTITY AND SIZE Of j INTER CONNECT TO HOOD FIRE CONNECTIONS AS REQUIRED FOR i SUPPRESSION SYSTEM BY F.P.C. EQUIPMENT BEING SERVED. FLEXIBLE APPLIANCE 01iii1 CONNECTOR FURNISHED MANUAL GAS BY FSEC AND INSTALLED VALVE (TYP) TYPICAL 6" DIRT LEG BY PLUMBING CONTRACTOR FLOOR TO 6" ABOVE FLOOR ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ACTUAL CONDITIONS. ATTACH RISER & HEADER TO WALL WITH 1" CLEARANCE BEHIND PIPE. MAKE FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURER. PROVIDE WELDED FITTINGS/JOINTS IN ANY CONCEALED, UNSLEEVED LOCATION. COOKING APPLIANCE GAS PIPE DETAIL NOT TO SCALE CONCENTRIC VENT THROUGH ROOF PER MANUFACTURERS REQUIREMENTS TANKLESS DISTRIBUTION UNIT WATER HEATER---------,,.`-+ MOUNT FLUSH (WHERE NECESSARY) COLD WATER SUPPLY I W/CEILING I 1/2" TRAP PRIMER LINE HOT WATER OUTLET UNION (TYP) I T&P RELIEF VALVE I GAS PIPING AT WATER HEATER T I j� N ;LAB 140' HOT WATER ! SEDIMENT TRAP u5 b BALL VALVE (TYP) 120' HOT WATER I COLD WATER CHECK VALVE TEMPERING VALVE RUN 3/4"0 RELIEF VALVE DISCHARGE LINE TO MOP BASIN. PROVIDE WITH MIN. 2" AIR GAP. DETAIL - WATER HEATER NOT TO SCALE AIR ADMITTANCE VALVE, RECOMMENDED MANUFACTURER TO BE "STUDOR", MODEL "MINI -VENT". PIPE CAP TO FIXTURE, SEE TILE FLOOR (SEE DRAWINGS FOR TYPE ARCHITECTURAL z FOR FLOOR SLOPES) - ADJUSTABLE d d DRAIN HEAD 0 5,-0„ MAX. d 1-1/2" VENT TEE DRAIN BODY FLOOR DRAIN DETAIL SCALE: NTS GAS VALVE EASY READ ON/OFF STAINLESS STEEL FLEX HOSE QUICK -7 DISCONNECT GAS MAIN PIPE TO EQUIPMENT EQUIPMENT GAS CONNECTION NOT TO SCALE CAULK DETAIL - AIR ADMITTANCE VALVE NOT TO SCALE DISCHARGE PIPE SCHEDULE 40 PVC WITH REDUCER (SIZE AS INDICATED ON DRAWINGS AIR GAP = 2 x "d" 4" A.F.F. (UNLESS OTHERWISE NOTED ON PLANS) FINISH FLOOR REFERENCE ID SHEETS. Q a e. d a.. PLUMBING EQUIPMENT SCHEDUL E-1 EQUIPMENT PROVIDED AND INSTALLED BY OTHER. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL REQUIRED ACCESSORIES (ie. WALL SUPPLIES, SUPPLY LINES, DRAIN, P-TRAP, GAS SUPPLY LINE, ETC.) FOR A COMPLETE FINAL CONNECTION TO EQUIPMENT. F-1 WHITE VITREOUS CHINA FLOOR MOUNTED FLUSH VALVE WATER CLOSET WITH ELONGATED BOWL FOR HANDICAPPED. AMERICAN STANDARD MADERA 17"H EL 1.6 MODEL 3043.102 WITH SLOAN REGAL 111 XL FLUSH VALVE, BEMIS 1955C OPEN FRONT SEAT AND BOLT CAPS. PROVIDE FLUSH VALVE WITH A.D.A. HANDLE TO MEET A.D.A. REQUIREMENTS. F-2 WHITE VITREOUS CHINA WALL HUNG URINAL. AMERICAN STANDARD LYNBROOK 1.0 MODEL 6601.012 WITH SLOAN REGAL 180-1 XL FLUSH VALVE AND HEAVY DUTY CHAIR CARRIER. INSTALL URINAL AND FLUSH VALVE TO MEET A.D.A. REQUIREMENTS. F-3 WHITE VITREOUS CHINA WALL HUNG LAVATORY FOR HANDICAPPED. AMERICAN STANDARD LUCERNE MODEL 0355.012 WITH AMERICAN STANDARD HERITAGE MODEL 5400.172V 4" CENTERSET FAUCET, MODEL 7723.018 OFFSET GRID DRAIN, 17 GA. POLISHED CHROME CAST BRASS P-TRAP, LOOSE T-KEY WALL SUPPLIES. INSTALL WITH JR SMITH MODEL 0700 HEAVY DUTY CHAIR CARRIER. PROVIDE UNIT WITH VANDAL RESISTANT WRIST BLADE HANDLES AND LEONARD POINT OF USE THERMOSTATIC MIXING VALVE MODEL 170-STSTL REC-BP WITH RECESSED STAINLESS STEEL CABINET AND COLD WATER BY-PASS. SET THERMOSTATIC MIXING VALVE WATER TEMPERATURE TO DELIVER MAXIMUM OF 1107.INSULATE DRAIN AND SUPPLY LINES TO MEET A.D.A. REQUIREMENTS. F-4 MOP SINK FAUCET. AMERICAN STANDARD EXPOSED YOLK WALL -MOUNT UTILITY FAUCET MODEL 8344.111. PROVIDE ROUGH CHROME PLATED FAUCET WITH VACUUM BREAKER, HOSE THREAD & PAIL HOOK ON SPOUT, INTEGRAL STOP ARMS. F-5 HOT & COLD WATER SUPPLY BOX LESS COVER. ACORN MODEL 8146. PROVIDE WITH VACUUM BREAKER AND 3/4" I.D. HOSE FOR CONNECTION TO HOSE REEL. F-6 CAN WASHING FLOOR DRAIN WITH RECESSED WALL MOUNTED WATER SUPPLY CONTROL BOX. SANI-CEPTOR J. R. SMITH MODEL 3380 AND WATER SUPPLY BOX J. R. SMITH MODEL 3380. PROVIDE WATER SUPPLY BOX WITH INTERGAL STOPS, VACUUM BREAKER, AND LOCKABLE COVER. F-7 HOT WATER TEMPERATURE TEMPERING VALVE WITH INTEGRAL CHECK STOPS, REMOVABLE CARTRIDGE WITH STRAINER. SYMMONS MODEL 5-40OB-W. FURNISH UNIT WITH SHUT OFF VALVE, THERMOMETER, UNIONS, WALL MOUNT BRACKET, AND LOCKABLE STAINLESS STEEL CABINET. MIXING VALVE SHALL BE SET TO DELIVER 120 DEGREES F. HOT WATER F-8 HOT & COLD WATER FREEZE PROOF SUPPLY BOX WITH LOCKING COVER. ACORN MODEL 8109. PROVIDE WITH VACUUM BREAKER AND 3/4" I.D. HOSE CONNECTION. CO-1 WALL CLEAN OUT, J. R. SMITH 4472-U WITH VANDAL PROOF SCREW AND STAINLESS STEEL COVER. CO-2 FLOOR CLEAN OUT, J. R. SMITH 4231-U-M WITH HEAVY DUTY VANDAL PROOF DUCTILE IRON TOP. FD-1 LIGHT DUTY FLOOR DRAIN, J. R. SMITH 2O05-B-P050-U WITH VANDAL PROOF TOP, SEDIMENT BUCKET AND 1/2" TRAP PRIMER CONNECTION. FD-2 MEDIUM DUTY FLOOR DRAIN, J. R. SMITH 2110-B-PO50-U WITH VANDAL PROOF TOP, SEDIMENT BUCKET AND 1/2" TRAP PRIMER CONNECTION. FS-1 12-1/2" X 12-1/2" X 8" DEEP FLOOR SINK, J. R. 3141-U. PROVIDE WITH SEDIMENT BUCKET, VANDAL PROOF GRATE AND 4" DEEP SEAL TRAP. HB-1 RECESS WALL MOUNTED FREEZELESS HYDRANT WITH CHROME FINISH, J. R. SMITH MODEL 5509QT. PROVIDE UNIT WITH LOCKABLE COVER AND VACUUM BREAKER. HB-2 HOSE BIBB, POST HYDRANT - WOODFORD MODEL RHY2 NON FREEZE WITH VACUUM BREAKER. DRAIN FROM CASING SHALL BE ROUTED WITHIN CEILING BELOW, OR TIGHT TO UNDERSIDE OF ROOF DECK, TO EXTERIOR WALL AND TERMINATE OVER GRADE. HOSE BIBB SHALL BE LOCATED ON ROOF. TP-1 TRAP PRIMER, MIFAB MODEL M-500. PROVIDE WITH MODEL MI -DU DISTRIBUTION UNIT AS REQUIRED. WH-1 COMMERCIAL GRADE INDOOR RATED TANKLESS GAS WATER HEATER WITH 199,000 BTU GAS INPUT; NORITZ MODEL NC199. PROVIDE WITH VENT TERMINATION KIT. INSTALL WATER HEATER IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, DETAILS AND SPECIFICATIONS, AS WELL AS IN ACCORDANCE WITH NFPA 54 AND THE 2014 FLORIDA FUEL GAS CODE. WATER HEATER SHALL BE SET TO DELIVER 140 DEGREES F. HOT WATER. SEE WATER HEATER DETAIL HUB DRAIN DETAIL SCALE: NTS FOR ADDITIONAL INFORMATION. BFP DOUBLE CHECK BACKFLOW PREVENTER WITH LEAD FREE CONSTRUCTION, WATTS SERIES LF7. PROVIDE UNIT WITH BRONZE STRAINER AND SHUT-OFF VALVES. SEAL BETWEEN PIPE AND SLAB WITH "THUNDERBOLT" LINK -SEAL MODEL PIDIE S MIPS THREAD in. DIMENSIONS (APPROXIMATE) AIR CHAMBER VVLUWla cubic in. FIXTURE UNIT CAPACITY A B in. in. 1250-A A 1/2 5 1/4 1 1/8 3.5 1-11 1250-B B 3/4 6 1/8,. 1 3/8 4.3 12-32 1250-C C 1 8 1 3/8 6.5 33-60 1250-D D 1 10 5/8 1 3/8 10 61-113 1250-E E 1 9 7/8 2 1 /8 22.36 114-154 1250-F F 1 13 7/8 2 1/8 34.4 155-330 NOTES: 1. SUGGESTED MANUFACTURER SHALL BE "WILKINS". 2. "PDI" REFERS TO THE PLUMBING AND DRAINAGE INSTITUTE. WATER HAMMER ARESTOR NOT TO SCALE LEGEND BALL VALVE (EXCEPT OTHERWISE NOTED) ----- COLD WATER (CW) ----- FILTERED COLD WATER (CWF) ----- LIME INHIBITED FILTERED COLD WATER (LICWF) ---^ter- CHECK VALVE C.O. CLEANOUT -D_ CONTROL VALVE/REGULATOR DOUBLE COMBINATION WYE CM FLOOR DRAIN FLOOR CLEANOUT GREASE WASTE (GW) ........... GAS (G) ------- HOT WATER (HW) - --- - - HOT WATER RETURN (HWR) INV. EL. INVERT ELEVATION PRESSURE RELIEF VALVE C PIPE RISERS (DROP) --0--0- PIPE RISERS (UP) - -� PIPE END (CAPPED) - STRAINER/FILTER SANITARY SEWER (SAN) S.A. SHOCK ABSORBER STORM DRAINAGE (ST) OVERFLOW DRAINAGE (OFL) -� TRAPPED DRAIN TRAP UNION - - VALVE (NORMAL CLOSE) - - - - - - - VENT (V) j,I'LVTR VENT THRU ROOF (VTR) WALL CLEANOUT ----------------------------------------------I I PLUMBING GENERAL NOTES I 1. SEE SPECIFICATION FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 2. COORDINATE HVAC EQUIPMENT AND DUCT LOCATION WITH HVAC CONTRACTOR. ( SEE MECH DWGs. FOR ADDITIONAL INFORMATION. I � 3. DO NOT INSTALL PIPING ABOVE ELECTRICAL PANELS OR EQUIPMENT. COORDINATE ELECTRICAL PANEL AND EQUIPMENT LOCATION WITH ELECTRICAL ( CONTRACTOR. I ( 4. RUN ALL HORIZONTAL COLD & HOT WATER PIPING ABOVE CEILINGS UNLESS OTHER WISE NOTED. ( I ( 5. EXTERIOR HOSE BIBS TO BE LOCATED 18" ABOVE GRADE UNLESS OTHER WISE I NOTED. I 6. INSTALL ALL WORK IN A NEAT AND WORKMANLIKE MANNER, USING ONLY WORKMEN THOROUGHLY QUALIFIED IN THE TRADE OR DUTIES THEY ARE TO j PERFORM. ROUGH WORK WILL BE REJECTED. � I 7. MAINTAIN A MINIMUM 10' CLEARANCE BETWEEN HVAC EQUIPMENT FRESH AIR I INTAKES AND SANITARY VENTS. t I ( 8. DOMESTIC WATER SHUT-OFF VALVES LOCATED ABOVE DRY WALL CEILINGS SHALL BE GROUPED TOGETHER TO PROVIDE ACCESS FROM SINGLE ACCESS I PANELS IF POSSIBLE. PROVIDE WITH IDENTIFICATION TAG INDICATING AREAS THE VALVE CONTROLS. ) I ) 9. UNLESS OTHERWISE DIRECTED, ALL DOMESTIC WATER AND GAS PIPING SHALL BE LOCATED AS HIGH AS POSSIBLE, TIGHT TO BOTTOM OF DECK/STRUCTURE. UNLESS OTHERWISEDIRECTED, STORM DRAIN AND VENT PIPING SHALL BE LOCATED AS HIGH AS POSSIBLE, TIGHT TO BOTTOM OF DECK/STRUCTURE, WITH MINIMUM SLOPE REQUIRED BY APPLICABLE CODE REQUIREMENTS. I I 10. COORDINATE ALL LATERAL CONNECTIONS WITH CIVIL ENGINEERING DRAWINGS, ANY CONFLICTS TO BE RESOLVED PRIOR TO START OF CONSTRUCTION. I I 11. CLEANOUTS ON 6" AND SMALLER PIPING SHALL BE PROVIDED WITH A I CLEARANCE OF NOT LESS THAN 18" FOR RODDING. CLEANOUTS ON 8" AND LARGER PIPING SHALL BE PROVIDED WITH A CLEARANCE OF NOT LESS THAN 36" I FOR RODDING. L-----------------------------------------------------1 FIXTURE UNIT CALCS. FIXTURE F.U. EACH TOTAL F.U. DESCRIPTION QTY WASTE WATER WASTE WATER COFFEE, ICE, SHAKE, SODA, ETC. 11 - 0.5 - 5.5 FLOOR DRAIN 6 5 - 30 - EMERGENCY FLOOR DRAIN 2 - - - - HUB DRAIN 2 2 - 4 - HAND SINK 3 2 2 6' 6 HOSE BIBB 4 - 2 - 8 LAVATORY 2 1 4 2 8 MOP SINK/CAN WASH 1 3 3 3 3 SINGLE COMP. SINK/PREP SINK 1 5 2 5 2 THREE COMP. SINK 1 6 4 6 4 WATER CLOSET 2 4 10 8 20 URINAL 1 4 10 4 10 WASH BOX 1 - 4 - 4 BUILDING TOTALS 68 70.5 TOTAL GPM - 58 REQ'D. PIPE SIZE 4 2„ Oil 111111" 06/29/1 ROBERT L. HINKLE PE 29302 POWELL & HINKLE ENGINEERING, P.A. GALTON C. MOK PE 33192 1409 KINGSLEY AVENUE, BLDG 12A P & H LANE R. HINKLE PE 48076 ORANGE PARK, FLORIDA 32073 THOMAS M, ELDER PE 56121 (904) 264-5570 FAX:(904) 278-2646 ENGINEERING CORPORATION FLA. REG. EB-4577 RICHARD DAVID R. A. MATHEWS SPELL JR. PE PE 59418 54729 l$/ No.4. 07 ST F OF R. Wulbern 2) Iu Architect PA AA - 0003433 Ilo . V (904)329-2510 tel . NU robert@wulbern.net. a'c U 2 9-Oi aoi c d d m m 2 c m C 0) rnw .N .c m > a �o m � 0 m -2c ' m m m d� a c m c � m m � a w � 0 z z Nle co 0 W a Lu x Y s (L x Lu 0 0 Lu E m m LL W r r r- � a- Q o 1` - � N a co 0 r 0 n 0 d d � CQ M X S _ N rir) O o o� z W U No Z Y I W� a = m Q 0 U ® 0 W 1� goldco , VVERTIC L O U J L0 CV z Q N rn O ZU t< YC, m X Z� _j litillitilitillY W = H O 0 20 LU Z) W =OWCO_j CO J mGz(U-)- m 7 ., , E�2 . 1 t , OP p jjj W O wzQ z�0 m Q W Q c :DU Uj a U F- i i W W In P`3- 1 )ORDINATE LOCATION OF REMOTE TEMPERATURE SENSOR ON SITE. PLENU_ MIZED CURB INSTALLATION NOTES 1. CAREFULLY LOCATE AND MARK ROOF CURB LOCATIONS SO THAT DUCT WORK CAN BE INSTALLED IN THE APPROXIMATE LOCATIONS AS SHOWN BY THE FLOOR PLAN. PAY ATTENTION TO THE LOCATION OF THE ROOF STRUCTURE IN ORDER TO ACCOMMODATE THE DUCT DROPS. 2. MARK THE EXACT LOCATION OF EACH ROOF CURB. LAY OUT ALL EQUIPMENT LOCATIONS IN ORDER TO MAINTAIN PROPER CLEARANCES FROM EXHAUST FANS AND VENTS AS WELL AS PROVIDING FOR PROPER SERVICE CLEARANCES. 3. GENERAL CONTRACTOR SHALL CUT ROOF DECKING MATERIAL TAKING CARE TO AVOID CUTTING ANY STRUCTURAL COMPONENTS. GENERAL CONTRACTOR SHALL ALSO INSTALL ANY NECESSARY FRAMING OR BLOCKING AT OPENINGS. 4. WITH ROOF CURB UPSIDE DOWN (SOLID METAL BOTTOM UP) MEASURE AND MARK THE LOCATION OF ANY JOISTS OR OTHER FRAMING MEMBERS THAT MUST BE AVOIDED. MEASURE AND MARK THE LOCATION OF ALL THE DUCT TAPS. 5. CUT ALL DUCT TAPS INTO THE BOTTOM PANEL OF THE ROOF CURB. BE CAREFUL NOT TO DAMAGE THE ROOFING SURFACE WHILE MAKING THESE CUTS. 6. INSTALL DUCT TAP FITTINGS AND MANUAL DAMPERS INTO THE OPENINGS PREVIOUSLY CUT. SEAL ALL CONNECTIONS ON BOTH THE BOTTOM AND THE TOP SIDES OF THE TAPS. 7. FLATTEN TAB OF START COLLAR INSIDE CURB, TIGHT AGAINST INSULATION. SEAL INSIDE OF COLLAR AND TABS TO INSULATION USING MASTIC DUCT SEALER. ALLOW SEALER TO DRY PRIOR TO PROCEEDING. 8. APPLY DUk'T SEALER TO OPEN END OF COLLAR. SLIDE INNER CORE OF FLEXIBLE DUUT ONTO COLLAR, AND CONNECT PANDUIT STRAP PER MANUFACTURERS INSTRUCTIONS. 9. SLIDE OUTER INSULATION SLEEVE OF FLEX TIGHT TO BOTTOM OF CURB. SEAL INSULATION TO BOTTOM OF CURB WITH PRESSURE -SENSITIVE FOIL TAPE. DO NOT USE TAPE MEANT FOR RIGID DUCTBOARD. SQUEEGEE OUT ALL AIR BUBBLES FOR PROPER ADHESION. 10. TURN CURB RIGHT SIDE UP, LEVEL CURB BETWEEN BOTTOM OF CURB AND DECK, INSTALL IN ROOF OPENING. SECURE CURB TO ROOF FRAMING AS REQUIRED, 11. GENERAL CONTRACTOR OR ROOFING CONTRACTOR SHALL FLASH AND ROOF IN fHE CURB AS DETAILED ON THE DRAWINGS. 12. INSIDE BUILDING, THE DUCT RUNS SHALL BE INSTALLED FROM THE TAPS TO THE DIFFUSER LOCATIONS AS SHOWN ON THE PLANS. SUPPORT PER SMACNA AND LOCAL CODES. 13. NOTE: IF NECESSARY, FLEX DROPS MAY BE CONNECTED TO TAPS AFTER CURB HAS BEEN INSTALLED. REFER TO STEPS #8 AND #9. FLOOR PLAN - HVAC SCALE 1/4" = 1' - 0" WHEN PLOTTED 36" X 24" 17-396 AIR BALANCE SCHEDULE TAG SUPPLY AIR OUTSIDE AIR RETURN AIR EXHAUST AIR BLDG. PRESSURE % OUTSIDE AIR RTU-1 2000 CFM 50 CFM 1500 CFM + 500 CFM 25 RTU-2 2000 CFM 500 CFM 1500 CFM + 500 CFM 25 RTU-3 3400 CFM 680 CFM 2720 CFM + 680 CFM 20 RTU-4 3000 CFM 600 CFM 2400 CFM + 600 CFM 20 EF-1 --- --- --- 1100 CFM* - 1100 CFM --- EF-2 I --- --- --- 800 CFM* - 800 CFM --- EF-3 --- --- ---1 225 CFM - 225 CFM 1--- TOTAL 10400 CFM Z280 CFM 8120 CFM 12125 CFM + 155 CFM 22 *NOTE: UPON START-UP VERIFY THAT THE EXHAUST FAN CURRENT SENSOR IS SET TO THE MOTOR AMPERAGE. IF IT IS NECESSARY TO ADJUST THE AMPERAGE OF THE EXHAUST HOOD FAN MOTOR, THE FAN MOTOR CURRENT SENSOR MUST BE RESET BY THE ELECTRICAL CONTRACTOR AS FOLLOWS: ADJUST UNDERCURRENT POTENTIOMETER TO MINIMUM (CLOCKWISE IS MAXIMUM.) APPLY CURRENT. ONCE CURRENT IS STABILIZED, INCREASE UNDERCURRENT POT UNTIL RED LED LIGHTS. WITHIN SEVEN SECONDS TURN DOWN UNTIL RED LIGHT TURNS OFF. IF A LIGHT REMAINS ON FOR MORE THAN TEN SECONDS, DISCONNECT SUPPLY VOLTAGE TO RESET. SEE MANUFACTURERS OPERATION -INSTALLATION INSTRUCTIONS THAT SHIP WITH THE FAN. WITH LIMITED BUILDING PRESSURE, THE ±10% TOLERANCE IS NOT ACCEPTABLE. SET CFM AS SPECIFIED. ENSURE THAT EXHAUST FAN PULLEY IS ADJUSTED FOR PROPER ALIGNMENT. AIR DEVICE SCHEDULE SYM. SIZE TYPE DUCT SIZE MODEL FINISH BOOT SIZE OPENING SIZE CITY. A* 24X24 SUPPLY 4 WAY 12"0 NCA12 WHITE 12"0 1 T- BAR 4 B* 24X24 SUPPLY 3 WAY 12"0 NCA12-3 WHITE 12"0 T- BAR 2 C* 24X24 SUPPLY 2 WAY PAR 12"0 NCA12-C WHITE 12"0 T- BAR 2 D* 24X24 SUPPLY 2 WAY CO 12"0 NCA12-C WHITE 12"0 T- BAR 2 E** 29"0 SUPPLY ROUND 12"0 3100-12 WHITE T- BAR 8 F*** 24X24 SUPPLY 1 WAY 8110 630 WHITE 6"0 T- BAR 2 G*** 124X241 SUPPLY 1 WAY 6"0 630 WHITE 6"0 T- BAR 1 H**** 24X24 RETURN 18"0 630FFTB WHITE 22X22 T- BAR 4 J 12X12 EXHAUST 8"0 RH-1 WHITE 12X12 SIZE + 1 4" 1 K 12X12 EXHAUST 6"0 RH-1 WHITE I 12X12 ISIZE + 1 4" 1 ALL DIFFUSERS SHALL BE MANUFACTURED BY METALAIRE OR EQUIVALENT AND 100% ALUMINUM CONSTRUCTION * PROVIDE WITH PVCR9 SLIDING -BLADE DAMPER ** PROVIDE WITH EIGHT 14"O-TO-12"O REDUCERS FOR TOPS OF DIFFUSERS *** PROVIDE WITH OPPOSED -BLADE DAMPER **** PROVIDE RETURN AIR FILTER GRILLE WITHOUT FILTER FOR REMOVAL AND CLEANING NOTE. LOCATION AND ORIENTATION OF DIRECTIONAL BLOW PATTERN DIFFUSERS IN THE KITCHEN IS CRrn AL INSTALLER WILL ENSURE PROPER INSTALLATION OF DIFFUSERS. CONTACT THE NCA CONSULTANTS PROJECT COORDINATOR IMMEDIATELY WITH ANY CONFLICTS THAT PREVENT INSTALLATION PER THE PROPOSED DESIGN. r�ux�rr� FAN SCHEDULE TAG EF-1 EF-2 EF-3 MANUFACTURER COOK COOK COOK MODEL 120 CPS-BK 100 CPS-BK 10OClODH LOCATION ROOF ROOF ROOF AREA SERVED BROILER FRYERS RESTROOM CFM 1100* 800* 225 STATIC PRESSURE "WG 1.85" 2.5" .25 FAN HORSEPOWER 1.0 1.0 1 25 FAN RPM 1957 2675 911 DRIVE BELT BELT DIRECT ELECTRICAL REQUIREMENT, V PHASE H 08-230 1 60 208-230 1 60 ROOF OPENING INCHES 22X22 22X22 ROOF CURB YES YES YES BACKDRAFT DAMPER NO NO YES BIRDSCREEN NO NO YES GREASE TROUGH IYES IYES INO INTERLOCK IYES IYES INO * SEE AIR BALANCE SCHEDULE NOTE. VERIFY ALL INFORMATION WITH MANUFACTURER PRIOR TO ORDERING AND INSTALLATION PACKAGE ROOFTOP UNIT SCHEDULE (RTU-1 ,2,3,4) TAG RTU-1.2 RTU-3 RTU-4 MANUFACTURER CARRIER CARRIER CARRIER MODEL 50KCA08 5 TON 50TCA09 8.5 TON 50TCA08 .5 TON LOCATION CURB DIMENSIONS ROOF 67" X 37" ROOF, 78" X 50" ROOF 78" X 50" TYPE OF HEAT ELECTRIC SMIp ELECTRIC STRIP ELECTRIC STRIP TOTAL COOLING CAPACITY MBTU HR 61.8 103.6 95.2 SENSIBLE COOLING CAPACITY M TU HR 46.2 78.5 71.0 ENTERING AIR CONDITIONS DB'F WB'F 80 67 80/67 80 67 AMBIENT AIR DB TEMPERATURE 'F 95 95 95 SUPPLY AIR CFM 2000 3400 3000 OUTSIDE AIR CFM SEE SCHEDULE SEE SCHEDULE SEE SCHEDULE EXTERNAL STATIC PRESSURE "W 0.75 0.75 0.75 BHP - MEDIUM STATIC MOTOR 2.9 3.7 2.9 E.E.R. 14.1 S.E.E.R. 11.2 11.2 HEAT/K.W. 12.0 16.0 12.0/16.0 12.0 16.0 UNIT WEIGHT LBS. 700 1000 900 ELECTRICAL REQUIREMENT, V P SE HZ 208-230 3 60 208-230/3/60 208-230 3 60 MINIMUM CIRCUIT AMPERAGE 53.0 59.0 48.3/54.6 51.1 57.5 MAXIMUM OVER CURRENT PROTECTION 60 60 60/60 60 60 ACCESSORIES: 1. MOTORIZED 25% OUTSIDE AIR DAMPER WITH HOOD ASSEMBLY - TO CLOSE AFTER-HOURS 2. NCA PLENUMIZED CURB. TO ORDER CALL TOLL -FREE (877) 530-0078. 3. ONE YEAR COMPLETE PARTS AND LABOR WARRANTY 4. ADDITIONAL FOUR YEAR PARTS WARRANTY COVERING COMPRESSORS 5. SMOKE DETECTOR (SEE HVAC ROOF PLAN, SHEET M-2) 6. AQUAGUARD AG-3180E MOISTURE SENSOR FOR PRIMARY PAN NOTE: COORDINATE RTU PLACEMENT ON SITE PRIOR TO SETTING EQUIPMENT. IF ADJUSTMENT IS NECESSARY MAINTAIN FRESH AIR INTAKE CLEARANCES 11 DRAWING INFORMATION 11 N•C•A C O N S U L T A N T S/ G R O U P 4585 140TH AVE. NORTH, SUITE #1001 CLEARWATER, FLORIDA PHONE: (877) 530-0078 CALL NCA MARKETING FOR PRICING NCA JOB# 17-394 R. Wulbern Mn oi Architect P-A '• O- AA-0003433 Iic. N U (904)329-2510 tel m U robert@walbern.net a .0 V O a U m 0) C a1 d G al c � O ma c � rnw m > 5) CONTRACTORS NOTES L E o HVAC CONTRACTOR o c c rn 1. THE HVAC CONTRACTOR IS TO FURNISH AND INSTALL THE HOODS, ROOF -TOP UNITS, EXHAUST FANS, N DUCTWORK, INSULATION WRAP, DIFFUSERS, SMOKE DETECTORS, AND TEMPERATURE CONTROLS. 2. THE HVAC CONTRACTOR IS TO VERIFY LOCATIONS FOR EF-1, EF-2, AND THE HOODS ON SITE FROM MOST -RECENT KITCHEN EQUIPMENT PLANS. ALL FANS ARE TO BE UL LISTED. a 3. ALL HVAC EQUIPMENT CURBS ARE TO BE SUPPLIED BY THE HVAC CONTRACTOR. m a m 4. ALL RTU CURBS ARE TO BE FABRICATED FROM 18 GA. GALVANIZED METAL WITH FULLY WELDED SEAMS, m N WATER TIGHT AND INTERNALLY INSULATED. FACTORY CURB CONVERSION SHALL NOT BE ACCEPTED. y c 5. SHIMS ARE TO BE PROVIDED BY HVAC CONTRACTOR BETWEEN THE ROOF DECK AND THE CURBS TO =ICa c COMPENSATE FOR ROOF PITCH. m c 6. ALL FLEX DUCT IS TO BE U.L. LISTED, R-6, FOIL -BACKED, CLASSIFIED AS A CLASS 1 AIR DUCT. MAXIMUM T _w LENGTH PER LOCAL CODE. c0 7. ALL METAL DUCT AND AIR DISTRIBUTION DEVICES ARE TO BE INSULATED WITH R-6, 2" X .75 DENSITY 2 2' FOIL -BACKED INSULATION, WITH FIRE AND SMOKE RATING [25]-[50]. a� o U 8. ALL DUCTWORK IS TO BE INDEPENDENTLY HUNG FROM STRUCTURAL MEMBERS. 9. ALL DUCTWORK IS TO BE FABRICATED, INSTALLED, SEALED, AND EXTERNALLY INSULATED PER SMACNA (NNF11 LOW -VELOCITY DUCT MANUAL (LATEST ISSUE). INTERNALLY LINED DUCTWORK IS NOT ALLOWED, r w 10. UNLESS OTHERWISE NOTED, ALL SUPPLY TAKEOFFS ARE TO HAVE A MANUAL VOLUME CONTROL DAMPER. E ac ai 11. THE HVAC CONTRACTOR IS TO COORDINATE DIFFUSER LOCATIONS ON SITE WITH THE MOST RECENT 'w u REFLECTED CEILING PLAN. H 0. w 12. THE HVAC CONTRACTOR IS TO FURNISH A WRITTEN GUARANTEE COVERING A ONE-YEAR PERIOD FOR ALL x HVAC EQUIPMENT AND PROVIDE AN ADDITIONAL FOUR-YEAR PERIOD FOR THE COMPRESSORS IN THE RTUS. Ln ALL FANS TO BE U.L. LISTED. z x 13. UPON COMPLETION OF PROJECT THE HVAC CONTRACTOR IS TO HIRE AN A.A.B.C. OR N.E.B.B. CERTIFIED, =i INDEPENDENT TEST AND BALANCE COMPANY TO CONDUCT A COMPLETE, CERTIFIED TEST AND BALANCE OF ALL HVAC EQUIPMENT. PROVIDE A WRITTEN REPORT TO NCA CONSULTANTS. ALL CAPACITIES MUST BE SET TO AMOUNTS INDICATED ON THE FLOOR PLANS AND SCHEDULES. Q U 14. THE HVAC CONTRACTOR IS TO MAKE ALL LOW -VOLTAGE WIRING FINAL CONNECTIONS FOR ALL HVAC 0 EQUIPMENT INCLUDING TEMPERATURE CONTROLS, RTUS, AND SMOKE DETECTORS. w a U) GENERAL CONTRACTOR 1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO RECEIVE, OFFLOAD, AND STORE ALL HVAC MATERIALS WHICH ARRIVE AT THE JOB SITE. ALL MATERIAL MUST BE STORED INSIDE THE BUILDING. HOODS = MUST BE STORED IN THE KITCHEN. U 2. IT IS VERY IMPORTANT THAT ACCURATE MEASUREMENTS ARE USED WHEN LOCATING EXHAUST FAN ROOF OPENING. COORDINATE ROOF OPENINGS WITH THE KITCHEN EQUIPMENT PLAN AND EXHAUST HOOD PLANS. a� OBTAIN THE CORRECT PLANS FROM THE KITCHEN EQUIPMENT SUPPLIER. O tl. 3. RTU ROOF OPENING SIZES AND ROOF CURBS ARE BASED ON EQUIPMENT SHOWN. IF OTHER EQUIPMENT IS 4 USED, VERIFY ROOF OPENING REQUIREMENTS. MAKE PENETRATION AS NEEDED FOR INSTALLATION OF NEW x CURB AND RTU. COORDINATE ON SITE WITH HVAC CONTRACTOR. ENSURE THAT ROOFING MATERIAL DOES NOT COVER THE TOP OF ANY HVAC EQUIPMENT CURB. z 4. ALL ROOF, CEILING, WALL, AND STRUCTURAL FRAMING REQUIRED FOR UNIT, FAN, DUCT, DIFFUSER, AND ALL OTHER HVAC WORK IS TO BE BY THE G.C. COORDINATE ON SITE WITH HVAC CONTRACTOR. GENERAL w CONTRACTOR IS TO PROVIDE ANY SCREENING, GUARD RAILS, ETC. FOR ROOF -MOUNTED HVAC EQUIPMENT PER x IBC AND LOCAL CODES. 5. IF NECESSARY THE GENERAL CONTRACTOR IS TO REMOVE, REPLACE, AND/OR REPAIR CEILING GRID AND Ld TILES IN ORDER FOR THE HVAC WORK TO BE PERFORMED. O ELECTRICAL CONTRACTOR EL 1. THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL PITCH POCKETS FOR POWER AND CONTROL a WIRING, AND IS TO MAINTAIN 12" MINIMUM CLEARANCE FROM BACK PANEL OF AIR CONDITIONING UNITS. DO w NOT PENETRATE BOTTOM OF RTU CURB. x 0 2. THE ELECTRICAL CONTRACTOR IS TO INSTALL LOW -VOLTAGE CONTROL WIRING FOR ALL AIR CONDITIONING CONTROLS. z 3. THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL DISCONNECTS FOR RTUS, WIRE THE RESTROOM W EXHAUST FAN TO RUN CONTINUOUSLY WHILE THE DINING ROOM LIGHTS ARE ON, AND WIRE KITCHEN / HOOD 0 EXHAUST FANS THROUGH THE OCCUPIED / UNOCCUPIED PANEL. NOTE: IF THE PANEL IS NOT UTILIZED, AND IF THE HOOD FANS ARE NOT CONTROLLED BY TEMPERATURE PROBES IN THE HOOD DISCHARGE COLLARS (SEE a HOOD DETAILS, THIS SET) THEN THE ELECTRICAL CONTRACTOR IS TO WIRE THE KITCHEN / HOOD FANS TO BE ENERGIZED DURING STORE OPERATIONAL HOURS. z Of 4. THE ELECTRICAL CONTRACTOR IS TO USE A MINIMUM OF 4'-6" SEALTITE FLEXIBLE CONDUIT WHEN WIRING O KITCHEN HOOD EXHAUST FANS ON ROOF SO THAT FANS MAY BE REMOVED FROM CURBS AND PLACED ON LU ROOF FOR CLEANING EXHAUST DUCTWORK. 0 5. FOR EACH UNIT, THE ELECTRICAL CONTRACTOR IS TO PROVIDE ONE SINGLE -GANG RECEPTACLE TEST 3: STATION FOR THE T-STAT, AND ONE DOUBLE -GANG RECEPTACLE TEST STATION FOR THE ANNUNCIATOR, WITH GREEN AND RED LIGHT INDICATORS. THE FIRE AND MECHANICAL INSPECTORS WILL DETERMINE SUITABLE w LOCATION FOR TEST STATIONS. ANNUNCIATORS AND TEST STATION WILL BE LOOPED IN THE CIRCUITRY OF THE O SMOKE DETECTION DEVICES. WIRING WILL BE INSTALLED BY ELECTRICAL CONTRACTOR. PLUMBING CONTRACTOR a. a 1. THE PLUMBING CONTRACTOR IS TO PROVIDE AND INSTALL CONDENSATE DRAINS/GAS PIPING FOR ALL HVAC Of EQUIPMENT, AND PITCH POCKETS FOR RTU CONNECTIONS. DO NOT PENETRATE BOTTOM OF RTU CURB. 0: O 2. THE PLUMBING CONTRACTOR IS TO COORDINATE PLUMBING VENT STACKS AND WATER HEATER FLUES WITH Z OUTSIDE AIR INTAKES OF A/C UNITS. 10'-0" MINIMUM CLEARANCE REQUIRED OR PER LOCAL CODE. ¢ 3. THE PLUMBING CONTRACTOR IS TO PROVIDE AND INSTALL FLUE GAS EXHAUST VENT FOR WATER HEATER. w MAINTAIN 10' 0" MINIMUM CLEARANCE TO AIR INTAKES 0 P 8/30/201812:07 PM in W m w a � Z W Z _o fn to Y z z a > < ¢ Y Y a 0: It LLIL > D m > m LLLL w H Q rn o � o cn v c\i ❑ o 0 r 0 � 0 d i zz n o N U U S O lY Of C 0 a_ p 3 Z W : U �O 3 L)i A w - o w U 0 H o o O a R ER LOCAL CODE. COORDINATE ON SITE WITH G.C. AND HVAC CONTRACTOR. W to W O J Z = J Eqgnesft 2 w d) Promss"* Ma ❑ = z z V Mechanical Engineers 0, EB-0006437 (n Z 1717 N. Howard Avenue Q w' Tampa, FL 33607 (813) 251-5848 0 L z Z I) w Q a]: d z C/ o W H z U) p Z O w ir Z w x ❑ w J D_ u 0 Q Z J O G ©C2017- Drawings, Z specifications, notes, database, computer files, field data, and reports as instruments of service ¢ w Q prepared by the Design of Record. As _ > instruments of services, these items remain the o N = property of the Design of Record, who shall ? retain all statutory and other reserved rights, z including the copyright thereto. Any use, ¢ reproduction or changes to these documents z without written consent of NCA Consultants is a M I violation of federal copyright laws. g OUTSIDE AIR HOOD. MAINTAIN 10'-0" MINIMUM FROM ANY EXHAUST OR PLUMBING VENTS (TYPICAL.) NOTE: DO NOT INSTALL SMOKE DETECTOR ON OUTSIDE OF CURB OR rtl SMOKE DETECTOR. INSTALL IN RETURN - SECTION OF CURB WITH SAMPLING TUBE IN SUPPLY AIRSTREAM (TYPICAL.) LOCATION OF ELECTRICAL DISCONNECT AND CONTROL WIRING ENTRANCE. REFER TO ELECTRICAL PLANS (TYPICAL.) r — — F_ — ELECTRICAL PENETRATION THROUGH ROOF WITH PITCH POCKET. PROVIDED 3Y ELECTRICAL CONTRACTOR (TYPICAL.) 1 SHIM BETWEEN BOTTOM OF CURB I(DASHED AREA CUR�)I AND DECK TO MAKE CURB LEVEL. — — — SHIM BETWEEN BOTTOM OF CURB AND DECK TO MAKE CURB LEVEL. CONDENSATE DRAIN WITH EXTERNAL, 4" DEEP P-TRAP INSTALLED BY HVAC CONTRACTOR. PLUMBING CONTRACTOR SHALL EXTEND DRAIN TO ACCEPTABLE LOCATION (TYPICAL.) ELECTRICAL CONTRACTOR AND PLUMBING CONTRACTOR WILL PROVIDE PITCH POCKETS FOR HVAC EQUIPMENT CONNECTIONS. DO NOT PENETRATE BOTTOM OF FAN OR RTU CURB, The General Contractor and the HVAC Contractor shall maintain distances from center of exhaust riser to the a/c unit curb as shown on this plan. Any discrepancies shall be reported immediately to the NCA Design Department at toll —free 877.530.0078 and the site —specific architect. I(DASHED AREA CURB SHIM BETWEEN BOTTOM OF CURB AND DECK TO MAKE CURB LEVEL. NOTE: FACTORY CURB CONVERSION SHALL NOT BE ACCEPTED. FOR ORDERING INFORMATION REFER TO THE NCA HVAC EQUIPMENT PACKAGE NOTE, SHEET M-1. NOTE: FLORIDA CODE CHANGED ON 01-01-2018 TO REQUIRE SMOKE DETECTORS IN THE SUPPLY AIRSTREAM. PREVIOUSLY SMOKE DETECTORS WERE REQUIRED TO SAMPLE RETURN AIR. CONFIRM ON SITE WITH THE INSPECTOR PRIOR TO INSTALLING THE SMOKE DETECTORS. (DASHED AREA CURB)? I \ I I \ SHIM BETWEEN BOTTOM ' °' !I ` OF CURB AND DECK I — — — I , J TO MAKE CURB LEVEL. r� \ HVAC CONTRACTOR SHALL NOT DISASSEMBLE THE EXHAUST FAN TO RECONFIGURE THE EXHAUST DISCHARGE DASHED AREA CURB) rej SHIM BETWEEN BOTTOM OF CURB AND DECK L — — — — -'J TO MAKE CURB LEVEL. EF-3 NOTE: MAINTAIN A MINIMUM 10' - 0" CLEARANCE FROM EXHAUST TO ALL FRESH AIR INTAKES (TYPICAL). ROOF PLAN - HVAC SCALE 1/4" = 1' - 0" WHEN PLOTTED 36" X 24" DUCT SUPPORT SUPPORT DUCTWORK WITH 1-1/2" WIDE, 22 GAUGE STEEL STRAPS FIRMLY ATTACHED TO THE BUILDING STRUCTURE. SPACING SHALL BE MAXIMUM 4'-0" FOR FLEXIBLE DUCTWORK. RIGID DUCT SUCH AS RESTROON EXHAUST SHALL BE SUPPORTED AS PER SMACNA LATEST DUCT STANDARD MANUAL. 12 GAUGE WIRE MAY BE SUBSTITUTED FOR LEVEL STRAPS IF 1-1/2" WIDE 22 GAUGE STEEL SADDLES ARE USED TO FULLY ENCIRCLE DUCT. REFER TO THE HVAC DUCT CONSTRUCTION STANDARDS PUBLISHED BY ROOFTOP UNIT SMACNA FOR ADDITIONAL DETAILS. FULLY COMPLY WITH MORE STRINGENT LOCAL MECHANICAL CODES. R/A PLENUM S/A PLENUMIN _ METAL GLASS TAB START COLLAR �IN $ WITH CRIMPED - ON S/A USE DAMPER W RIGID LEVELING MATfi2 L MASTIC - LOCKING QUADRANT. ROOF DECK EXPOSED DUCT AT EXPOSED CEILING AREA. SEE DAMPER SEE DAMPER LOCATIONS LOCATIONS ON ON FLOOR PLAN -- -- HVAC FLOOR PLAN --- VIEW VIEW - ---- - - -_ - VIEW— EFOSED STRUCTURE TO ROOF -NCK LAI_UMINUM ROUND DIFFUSER AS SCHEDULED EXPOSED UNINSULATED DUCT/INSTALL DETAIL NOT TO SCALE I A/C CURB CURB I ~ SUPPORTS FOR FLEX DUCTWORK SHALL BE PLENUM SPACED AT 4'-0" MAX. FLEX DUCT SHALL ROOF DECKING SAG NO MORE THAN 1/2" PER FOOT OF RUN. METAL START COLLAR WITH DAMPER. 1-1/2" WIDE 22 GAUGE STEEL STRAP ATTACHED TO ROOF STRUCTURE TO1 PREVENT SAGGING. III RADIUS EQUAL TO THE FLEX DUCT DIAMETER ALL DUCT INSULATION SHALL HAVE A MINIMUM INSULATING VALUE OF R-6. U.L. NON -ASBESTOS NOTE USE -FLEXIBLE DUCT- ONLY, NOT INSULATING BLANKET -FLEXIBLE CONNECTOR.- IF LOCAL CODE BAND CLAMP AND TAPE LIMITS LENGTH OF FLEXIBLE DUCT, USE EXTERNALLY INSULATED SNAPLOCK PIPE TO FLEXIBLE DUCT, TO GRILLE/DIFFUSER ALUMINUM DIFFUSER OR GRILLE AS SPEC. DUCT SUPPORT SUPPORT DUCTWORK WITH 1-1/2" WIDE 22 GAUGE STEEL STRAPS FIRMLY ATTACHED TO THE BUILDING STRUCTURE. SPACING SHALL BE MAXIMUM 10-0" FOR RIGID DUCTWORK, AND MINIMUM 4'-0" FOR FLEXIBLE DUCTWORK. 12 GAUGE WIVE MAY BE SUBSTITUTED FOR STRAPS IF 1-1/2" WIDE 22 GAUGE STEEL SADDLES ARE USED TO FULLY ENCIRCLE DUCT. REFER TO THE HVAC DUCT CONSTRUCTION STANDARDS PUBLISHED BY SMACNA FOR ADDITIONAL DETAILS. FULLY COMPLY WITH MECHANICAL CODES. RIGID/FLEXDUCT CONNECTIONANSTALL DETAIL NOT TO SCALE DUCT SCHEDULE SIZE GAUGE 6"0 - 8"0 28 10"0 - 12"0 26 14"0 - 16" 0 24 18"9 - 20"0 22 ,['+ram � �- :1►., r� i 'r 21 N •C •A C O N S U L TA N T S/ G R O U P 4585 140TH AVE. NORTH, SUITE #1001 CLEARWATER, FLORIDA PHONE: (877) 530-0078 CALL NCA MARKETING FOR PRICING NCA JOB# 17-394 R• Wulbern L Architect PA AA - 0003433 lic WVO (904)329-2510 lel N .02 roberlQwulbem.nel• 0 a � Engtvreerhg PPOfessk a* ha a1 Mechanical Engineers +� 0 0-0006437 C 1717 N. Howard Avenue m w Tampa, FL 33607 (813) 251-6848 y y �> m a) b D ID �E oa m c p1 N .L. � m m a-Oi ii aU �a N h� c � N �O c a� .N C m a .N U � d oQ a c d � U c° a) t � E SD m w E FACTORY CURB CONVERSION SHALL NOT BE ACCEPTED. F m NCA PLENUMIZED AC CURB DETAIL NOT TO SCALE ISOLATION GASKET - FULL PERIMETER OF ROOFTOP EQUIPMENT ROOF EQUIPMENT CURB PERIMETER FRAMING TIED — TO STRUCTURE BY G.C. z LL LL r J J U LL U w a a A/C UNIT RAIL OR FAN BASE FLANGE 14 TEK SCREWS THRU STRAP, UNIT ~ RAIL, CURB, WOOD NAILER AND CURB U BASE. NO MORE THAN 6" FROM EACH 2 CORNER AND BETWEEN SCREWS. tr 0 `BUILT UP CANT- BY G.C. LL H / RIGID LEVELING MATERIAL (SHIM = / -AS REQ. TO COMPENSATE FOR ROOF PITCH) z 2 H Uj w x 0 O ui /n 0 a of D a W w L-SECURE CURB TO MIN. 3 X 3 X j ANGLE IRON WITH MIN. J" BOLTS BY = REQUIRED LENGTH WITH FENDER WASHERS, LOCK WASHERS & NUTS ® EA. O SIDE OF FAN CURBS & 4 PER LONG SIDE OF ROOF TOP CURBS & 2 AT >- EA. SHORT END EQUALLY SPACED - START FROM CORNER A MIN. OF 6", z ON ROOF TOP A/C CURBS. GENERAL CONTRACTOR SHALL PROVIDE STRUCTURAL PERIMETER FRAMING FOR EDGE SUPPORT OF CURB AS O ILLUSTRATED IN THIS DETAIL FOR HURRICANE FASTENING LL tY LL ACCEPTABLE FOR 170 MPH ZONE z ROOF EQUIP. CURB MOUNTING DETAIL 0-1 Uj Ox NOT TO SCALE ACCEPTABLE FOR 170 MPH WIND ZONE LEVEL ��IDENTIFICATION AG WITH UNIT NUMBER AND EA SERVED UNIT RAIL CANT STRIP BY ROOFING CONTRACTOR CURB INSULATION — RETURN SECTION SUPPLY SECTION 0 w ROOF MOUNTED o PACKAGE A/C UNIT O d w K O 0 z Uj win RUUh INSULATION m t— ( z i Q 0 SHIM AS NEEDED BETWEEN z BOTTOM OF CURB AND ROOF DECK AS NEEDED TO COMPENSATE FOR ROOF PITCH. TRUSS (TYP.) SEE HVAC FLOOR PLAN FOR CONTINUATION NOTE: INSULATE ALL COLLARS. SEAL TO PLENUM AND FLEX INSULATION DUCT RISER/LEVELING DETAIL NOT TO SCALE SHANE H tk !Leo® 1717 No A° °►Aj�PA, FL FLOR E1g1 4 r No 420 ` �O•, ST TE OF l�e °ONA, CO Copyright 2017- Drawings, specifications, notes, database, computer files, field data, and reports as instruments of service prepared by the Design of Record. As instruments of services, these items remain the property of the Design of Record, who shall retain all statutory and other reserved rights, including the copyright thereto. Any use, reproduction or changes to these documents without written consent of NCA Consultants is a violation of federal copyright laws. M0201812:07 PM h � � s w w a w � (n z ¢ o 111 z U _O N (A Y z z a Y Y a F w 0 0 it m m LL LL W ~ O \ i�3 N 0 0 0 IL i z zz � e N (� t Ir) a 0T�'', a Z�', w ; I- Z Y a Lu _ a Of 0 x u 0 lz a J z' 0 a H o'' W m 0 Z lu Q lu j 2 � z 3 Q w Q J J 0_ w J Li o H Q' W U Q T NORTH AMERICAN BROILER/OVEN HOOD - DUKE BROILER \ BROILER/OVEN HOOD MODEL: ELX-ND-BDL-PM-OB43{SK-NA-BOH-7-7) Manufactured by: Gaylord Indusbim Broiler/Oven Hood Specifications Gaylord Model ELX—ND—BDL—PM—OB-43—(BK—NA—BOH-7-7), canopy style wall mounted broiler/oven hood 7'-7" long x 43" front to back. The hood is apecifioaly designed to go over a Nieco MPB94 or Duke FBB broiler and a half size convection oven. The hood is designed for either a Standard or Reverse ROC building. The ends and front panels are insulated double wall construction, and the top is covered with 3" thick insulation. The hood utilizes patented high efficiency stainless steel Gaylord XGS Extractors. The extractor testing mirror ASTM Standard F2519 —2005, and are ETL Listed to UL Standard 1046. The hood design includes a buiN in 5" air space at the back for allowing direct mounting to a limited combustible wall (sheet rock on metal studs) for compliance to NFPA-98. Also built into the back of the hood are utility raceways that are used for gas piping and electrical services. The hood includes factory pro -piping for an Amerex KP firs extinguiahtng system or as an option may be pro -piped for an ANSUL R-102 fire system. The hood is constructed of all 18 gauge, type 300 series Stainless steel, number 4 finish. Enciosura Panels Included is a Stainless steel enclosure kit to fill the space between the top of the hood and the finished ceiling. The panels are constructed of 18 gauge type 430 Stainless steel, number 4 finish. Wall Flashing One set of wall flashing for broiler/oven hood as shown on the drawings. Flashing is constructed of 18 gauge type 430 stainless steel, number 4 finish. Hanging Wetahtr The hanging weight of the broiler/oven hood is 450 lbs. HOOD LISTING AND API-'ROVAL REFERENCE BROILER/OVEN HOOD NSF —NATIONAL SANI'TATiON FOUNDATION INTERTEK TESTING SERVICES, INC. N AL Ilttlwo M OF WIF sKMIDMID NOs 800 0 HOOD B LIL NISI® BOYUST HOODS R Mff 'F'OM St?RNCE EMWMEIr OHNIST WMERS. REPORT NO. 31305001111 TESTED UNDER ULSDN ND ro. MECHANIC& CODES n NATIONAL FIRE PROTECTION ASSOCIATION IEEIs "L tKwu�3oNTs uc M SOW AND � �'P' MESS ALL REQUIREMENTS OF NWA-90 %7AM FOR wRwaN CONTROL s FIRE FRORICHON OF NEW YORK CITY DEPARTMENT OF BUILDING 3.5" MINIMUM SIDE OVERHANG TO MOILER REWIRED FRONT ELEVATION WITH DUKE FEB BROILER SFE NOTE t NOTE 1• BRMBt JW BE POM OED 10 BU FROM FRONT OF HOOD DUKE FBB BROILER .I. le' Dw LEG -,�IOVD Ell WELDED GREASE -- nwr, csc I. I 32 43 O.D. EXH EXHAUST DUCT SIZE: 10" DIA 45. MOUNTING/HANGING CFM DUKE BROILER: 1100 ANGLE EXH S.P. DUKE BROILER: 1.0 FPM DUKE BROILER: 2 7 NfLECT. RACEWAY RACEWAY `ELECT. RACEWAY /8" CHEMICAL LINE. — 1 n• ZI A- METAL EAB HEMICAL INLET DUCT PLENUM COLLAR -- NOZZLE WELDED WELDED IN PLACE U SHOWN BY GAYLO 450" LINK I 88.5" I.D. BROILER/OVEN HOOD 7'-7" PLAN VIEW - FIRE SYSTEM PIPING LOCATIONS ELECTRICAL GAS PIPE ELECTRICAL RACEWAY RACEWAY RACEWAY 1" GAS PIPE TO THIS POINT BY JT9T GAYLORD. 7" 1. NIECG MPS94 BROILER REQUIRES 208-24CM 30 AMP -- - --- -----. NEMA TWIST LOCK LG 3OR — — — 2. DUKE BROILER REQUIRES SINGLE RECEPTACLE NEMA 52OR HOSPITAL GRADE HANGING ANGLE .25 1.25 (TV) 4X4 CONNECTING J-BOXES. ELECTRICAL CONTRACTOR TO WIRE FROM THIS POINT To ELECTRICAL. PANEL II II II II / II DETAIL"A" (ORANGE) 120V/2GAMP. 3. IF LOCAL CODE REQUIRES G.F.I. PROTS:IION, THE PROTECTION SHALL BE PROVIDED IN THE II II II I I II II REMMNINC CAME RM CIRCUIT BR�BREAKER PANEL BY THE ELECTRICIAN. II II II II (n GAYLORD) o.>S 1.5 SPARE J-BOX WITH BLANK S/S II. II II. II. I SEE DETAL *A! 120V 20 AAUP DUPLEX RECEPTACLE FOR M �- I-28 XT 19.5—I 120V 20 AMP DUPLEX RECEPTACLE X 3-1/2 BOX FOR EITHER NIECO FOR HOLDING CABINET OR DUKE FBB BROILER. 4x4x3.5 J-BOX WITH 3 #10 WIRES ICAL CONTRACTOR TO FURNISH AND GROUND. ELECTRICAL �RIATE RECEPTACLE AND 1"x ' REWC CONTRACTOR TO SUPPLY SEE NOTES 1 h 2. W/CAP RECEPTACLE AND COVER PLATE FOR SPECIFIC OVEN USED FRONT ELEVATION UTILITY CHASE E. THIS DRIDM WIGS BE AA 111114 'M OF 18. 70 MEET CODE REQUIREMENTS NOTE CURB CAP -TO -CURB JOINT MIST BE AIR TTOHT. 6. E CD NIRACIOR MUST APPLY SEAIANT TD JOINT AND SCREW CURB CAP 70 CURB. BOIL TA J-BD)E.4 MOUNTINGAIANGING ANGLE (SEE SHEET IS) BUILT IN UTILITY RACEWAY (SEE SHEET 0) u (5) 11W x 16T "XGS" INK PER HIGH EF'M iFASE N GREASE EXTRACTORS-1" IIFACTORY WIRED 7'-11" RECEPTACLES AND PRE PIPED GAS LINE (SEE SHEET 10) 1 1 2 MOUNTING 5" �F�gLLANGE (SEE SHEET INSTIL DORMONT POST -SET GUIDES 2'-10" l (ElY OTHER NOIE 1 . ° - FOLLOW DC INSTALLAna INSTIRUCIIG _�. BROILER HOOD SECTION WITH NIECO MPB94 BROILER 0, - �N LAL r- \T I cc I I. CHFV_11_'AI. PIPING -� ,LAPS T:. -i R.- t'F I j1A AMEREX PIPING DETAILS BROILER/OVEN HOOD BROILER HOOD ENCLOSURE PANELS INSTALLATION INSTRUCTIONS D7ESTOR BRAC,iI,FTS .I IonlcurD 2r. INSTALLED I_. DRAWING INFORMATION DESCRIPTION By 5'-7" NORTH AMERICAN FRYER HOOD (FREE STANDING) FRYER HOOD MODEL: ELX-ND-BD-38-(BK-NAFH5-7) Manufactured by: Gaylord Indusbies Fryer Hood Specification Gaylord model ELX-ND-BD-38-(BK-NAFH-5-7) low proximity, freestanding hood 5'-7" long x 38' front to back. The hood is designed to go over either a 3 Basket/2 Basket/3 Basket Fryer Configuration, or a four 2 basket fryer configuration. This hood Is not designed for a 3 Basket/2 Basket/Fry Dispenser/3 Basket configuration. The hood utilizes patented high efficiency stainless steel Gaylord XGS Extractors. Also built into the back of the hood are utility raceways that are used for gas piping and electrical services. The hood includes factory pro -piping for an Amerox KP fire extinguishing system or as an option may be pro -piped for an ANSUL R-102 fire system. The hood is constructed of all 18 gauge, type 300 series stainless steel, number 4 finish. Enclosure Panels Included is an enclosure kit to fill the space between the top of the hood and the finished ceiling. Lift -out doors in the front and right panels are provided to gain access to the duct access panel, fire protection equipment and static pressure tap. Panels are constructed of 18 gauge type 430 stainless steel, number 4 finish. Optional Wall Flashing One ask of wall flashing for the fryer hood as shown on the drawings. Flashing constructed of t8 gauge type 430 stainion at". number 4 finish. wal The hanging seight of the fryer hood is 350 Ube. HOOD LISTING AND APPROVAL REFERENCE FRYER HOOD NSF -NATIONAL SANITATION FOUNDATION bTMWIM INTERTEK TESTING SERVICES, INC. 1NU EEIS NSF FFIYER HOOD Is ETL LISTED: E*MUST HOODS wmTa lolIT oD SERVICE EQUIPMENT" NSF. T Ito 920930Rr-002. TERM To•, MECHANICAL CODES OCLINTION VENTILATION MEETS ALL AND ��I VTS OF THE UMC, Back CONTROL t FIRE PROTECTION OF COMMERCIAL COOKING .. OPEPA70W -- METAL FAB DOUBLE LINED DUCT, FIRE, 3G SERIES, UL 2221 LISTED FOR BRACKET BY GAYLORD. ZERO INCH CLEARANCE BOLTED TO TOP OF HOOD. To GOMBUSTI I n 7-S/S ENCLOSURE PANELS BY GAYLORD 'II UFT OUT PANEL TO FIRE SYSTEM FIRE SYSTEM FOR FRYER AND BROILER 1 ENCLOSURE HOODS . IELS EY GAYLORD �( THISDARD LOCATION FOR THE FIRE SYSTEM SERVING BOTH THE GREASE DRAWER © :. FRYER HOOD R BROILER HOOD. (SEE DETAIL) / AS AN OPiION THE FIRE NOTE. 2" MIN. SYSTEM MAY BE WALL OVERHANG FOR COMPLIANCE L-J. �� �'" " -1 MOUNTED. (SEE DETAIL) U.L HPtKfI fU5\fl o E452E1 fFYEi rNYci rHYf.H 0 y ~ 1 Ij r A & Y r P 107 FINE A54 FFrf 1yeR FRYN 2YfF i FRONT ELEVATION 1 FRONT ELEVATION 2 1ST BEST PRACTICE 2ND BEST PRACTICE IMPORTANT NOTE: Tbis drawing depicts two basic fryer configurations approved by Burger King Corporation. NOTE THIS DIMENSION MUST BE A MINIMUM OF 18" TO Lam0001L RW MEET CODE REQUIREMENTS NOTE: CURB CAP -TO -CURB DUCT EXTENSION BY -�.� ¢ - :.. JOINT MUST BE AIR TIGHT. CAYLORD INS7 CONTRACTOR MUST APPLY BY SEALANT TO JOINT AND ry Ter rvrruCrtw-/T. SCREW CURB CAP 10 CUTE. -_IIOXI SELL EE WELDED ORFASE S/S ENCLOSURE I. 28' 17" So 34" 4 FRYER HOOD SECTION VIEW N•C•A C O N S U LT A N T S/ G R O U P 4585 140TH AVE. NORTH, SUITE #1001 CLEARWATER, FLORIDA PHONE: (877) 530-0078 CALL NCA MARKETING FOR PRICING NCA JOB# 17-394 R. Wulbern t Architect PA. •PJ AA-0003433 Ile N (904) 329.2510 tel « 0) 0 roberttitm1bem.nel« ' .a C 8 0 m 5Q) C 4) Engkeav ft D.a C La Professionals, bic, d c M o Mechanical Engineers EB-0008437 C 4) 1717 N. Howard Avenue Tampa, FL 33607 (813) 251-6a48 2> .5 m :a N v w E E o P m °c 0) N N c m m d A a) N c v m a .D c m me N O) >` N � y o (' a Ta m8d c am .0 c d L 49 E 0 = -M w 2 Z LL LL J 0 LL 0 w D_ rn Q 0 U 2 O w Q 2 Z K w 0 0 W In O 0- 0_ fY w 0 O Y z O LL a z K 0 w J 0 Z W O ❑ 0 1r LU w o_ O 0 Z DUCT EXThm RE PIPED ¢ BY (;A "FIRE SYSTEM p w CONNECTING J-BOXES MOUNTING ANGLE cars AB EXTRACTOR O Z "XGS" SUPER HIGH EFFICIENCY GREASE EXTRACTOR (4 EACH 11"H X 18"W) GREASE DRAWER Z BUILT IN UTILITY RACEWAY (SEE SHEET 11) IMPORTANT NOTE ¢ BEST PRACTICE IS TO INSTALL Q _ FACTORY WIRED DORMONT POSI-SET GUIDES ON I- RECEPTACLES AND THE REAR CASTERS OF EACH W PRE PIPED GAS FRYER. THIS ENSURES PROPER Lu 8 LINE POSITIONING OF THE FRYERS FOR LL THE FIRE PROTEIONOZZLES Z 1.5" MOUNTING FLANGE (SEE SHEET 21) AND OPERATION OF 7H HOOD. O INSTALL DORMOM' POSI-SET GUIDES POSITION THE LEFT FRYER 2" IN rn (BY OTHERS) FOR FRYER REAR CASTER FROM THE U}T EDGE OF HOOD. r WHEELS ON FLOOR TO ENSURE PROPER PUSH FRYER BACK UNTIL ACTS THE BACK OF TTr 0 HE FILECOPY Lu FRYER POSITION UNDER HOOD. HOOD. THEN FOLLOW THE DORMONT INSTRUCTIONS FOR = MOUNTING THE POSI-SET GUIDES ❑ TO THE FLOOR. POSITION THE FRY ERS YERS ACCORDINGLY h Z INSTALL THE POSI-SETS. < THE POSI-SET GUIDES ARE NOT O PROVIDED BY GAYLORD. O Z FRYER EXHAUST FAN SPECS COOK MODEL 100 CPS: SW CFM. S.P 2.5. CM ROTATION O 2675 RPM, 1 HP 208V/1 PH/80 MOTOR, UL 782, HI-iTMP EEZ CLEAN OAT, STEEL ACCESS DOOR, STEEL DRAIN, HANGING GREASE TROUGH, PREWIRED NEMA 3 DISCONNECT, HORIZONTAL DISCHARGE WITH UL 762 PUNCHED FLANGE, PREWIRED CURRENT SENSOR, ROOF CURB CAP do INLET BOX. ROOF CURB SPECS COOK MODEL RCG-30x48x18 NO NAILER U.L�USTED GREASE EXHAUST DUCT MANUFACTURED BY METAL-FAS, MODEL 3G SERIES USTED FOR "0" TO COMBUSTIBLES, 8130/2018 12:08 PM a Cn S Z N r d d' IL wa Lu w 04 04 Y ale Q 0 �m o mLL 0 h t` I- r M - Z, Q o O ro O I. n N 0 0 0 oll a or s � A Z SO LU U so Z Y • w — It U, m a X o c� O o © Copyright 2017- Drawings, F- w specifications, notes, database, computer files, 2 _ field data, and reports as instruments of service o a) i prepared by the Design of Record. As z Instruments of services, these items remain the ❑ property of the Design of Record, who shall a retain all statutory and other reserved rights, including the copyright thereto. Any use, Z reproduction or changes to these documents without written consent of NCA Consultants is a ❑ violation of federal copyright laws. _ FIRE PROTECTION SYSTEM NOTES ANSUL R-102-MS l[I IN R ACKE IS, T ' E ALLED. (,LAIN OF OF iTI E DROPS FR F ,' V NTI ATOP A TH TII >I I1'TI rl 'J+ LL'I I 1 1 In L AEru,t,. L� ^N' AND PERMITS UNION LABOR AND 'PREVAILING WAGE FARTS AND INSTALLATION OF CHEMICAL 1ETECTION LINES_. FROM, TANKS TO , AN EC 4DN 0iNTS ON HOOD TANKS AND INSTALLATION OF TANKS AND RELATED COMf"\ti.NTS' AS VALVE(S) AND INSTALLATION OF 'AS v'A V cl FARIti FOR AND INS'lA'A ION OF PTMOIE: A; J IAL PLLL STATION(S) C SC MCAL DISCONNECTS ART' AND LABOR -OR A,NP ELECTRICAL GNTFFSCONNFCTIONS OR SITE, RFPOSITIDNINC OF TERMITNIATFFI ,APPLIANCE DROPS, IF r O JKIy ` EO PPH-.NT IS IN4LLEIJ Pc2 .,NYLON L A-FPOA/ v 'DRAWINGS ' :RIP TEST A`a0 ,,ERTIFICA.TION APP:_IANCE PIPE DROPS AND NOZZLES MIC,AL * DETECTOR CABLE " U B'-E UNIAS AND LINKAGE * MANOAL RESET RELAY(S) * HANDHELD FIRE EYTINGUJS,PI (S) * INSPECTION AND SERV'-.LING 4X4 CONNECTING J-BOXES: ELECTRICAL CONTRACTOR TO WIRE FROM THIS POINT TO ELECTRICAL PANEL 0 D. CHEMICAL BBBBBBBBI,[,Biiininnion II —� (3) FRYER .• _Mr� CHEMICAL II ` T 5*4ill� TANK 2-5111-1 FRYER•, IG ._. � 13.125 I--17 i--17--I 9.75 PLAN VIEW - (OPTIONAL) ANSUL FIRE SYSTEM PIPING LOCATIONS • • _■ill h _�� , r1m N � L `�IIII �:,� M Y TANK IMONI 'PLAN VIEW - AMEREX FIRE SYSTEM PIPING LOCATIONS 38 O.D. �IIII Y - F PLENUM NOZZLE TO BROILER/OVEN HOOD DETECTION #11 INLET DUCT NOZZLE HPF-HOOD PENETRATION FITTING DU #18416 NPF NOTE: THIS DROP IS CHEMICAL THIS OUTLET IS PLUGGED BY GAYLORD. _ONLY USED WHEN FOUR INLET R IS USED FOR THE FOUR FRYER CONFIGURATION. FRYER CONFIGURATION MRM IS USED. IMPORTANT NOTE: THE HOOD IS PRE -PIPED FRYER NOZZLES WITH NOZZLE DROPS FOR THREE FRYER 360 DEGREE #11982 (8-TYPICAL) CONFiGuRATKIN. As sHOWN ON SHEET 5.1 FUSE LINKS-' FRONT ELEVATION #2 IF THE FOUR FRYEER CONFIGURATION. AS SHOWN ON SHEET 5.1 HPF ELEVATION f3, IS USED, OR ANY OTHER "HLM.CAL -IP NG FRYER CONFIGURATION IS USED. THE IT AMEREX DISTRIBUTOR SHALL REPOSITION THE NOZZLES BY ARMING" OVER AS REQUIRED. IMPORTANT NOTE: DETECTOR BRACKETS FURNISHED h ALL OA' OF F GAPS 10 EH HIGH INSTALLED BY GAYLORD. IENIP112API'„ IRE PJLTAL AMEREX PRE -PIPING DETAILS FRYER HOOD (DETECTION AMEREX CHEMICAL, TO BROILER/OVEN H IMPORTANT NOTE HOODS MUST NOT BE SEPARATED NOTE THIS DROP IS PAST 28'-0' TO MEET AMEREX \FRYER CONFIGURATKN ONI USED WHEN R REOUIREMER75 / IS USED. 0011982 --3.75 ) IS ®#1841 MRW NOTUTLIZEIN THE THREE m � p10 AMEREX EF HOOD T (ON TOP OF HOOD OR OPTIONALLY ON A FRYER CONFIGURATION. A USE (2) AMEREX KP375 TAN t HPF-HIXUD PENETRRATION FRTING DM�q AMEREX FUSE LINK DETECTOR DETECTOR BRACKETS FURNISHED W/ 45O FUSE LINKS ME INSTALLED BY GAYLORD. +11 AMEREX FUSE LINK INLET ((QQ DUCTZ S2) #11 ■ amc rulao N awm. S@� PLP M NN�OZZZLE (2) 711 el�■�Oa Yw'��I��-_ 1tBB NOZZLE #11982 ■■mrs m s ■om sfA71C 100 DIA METAL FAB EXHAUST DUCT DIP SON COLLAR CONIINIKXJSL CFM: 800 YIELDED IN PLACE AS Ste: 10• DIA SHOWN gY GAYLARD S.P.O COLLAR: 1.050 th.Q FPM: 1457 PLAN VIEW UTILITIES -I' GMs PIPE m POINTTHIS GMM SM FWFIL MZML 1. IF LOCAL CODE REWIRES G.F.I. PROTECTION, THE PROTECTION SHALL BE PROVIDED IN THE CIRCUIT BREAKER PANEL BY THE ELECTRICIAN. 11' GAS DROPS. REDUCED TO 0.75• DROPS BY GAYLORD X 4 BOX WITH #8-15R RECEPTACLE FOR PRODUCT HOLDING CABINET AMEREX PRE -PIPING DETAILS FRYER HOOD N IANUAL T MULL STATION 1 III O EVE EVE AMEREX PIPING BY F.P. INSTALLER — INTERIOR HOLD AMEREX PIPING BY GAYLORD ROOF TOP AMEREX PIPING BY GAYLORD AMEREX FLOW POINT CALCUALRON CHART BROILER HOOD/ BROILERH00D/ FRYER HOOD DUKE NIECO TOTAL# TOTAL# TOTAL# No' Ie FLOW OF FLOW TOTAL OF TOTAL OF TOTAL Paa# POINTS NOZZLES POINTS FLOW NOZZLES FLOW NOZZLES FLOW EACH RECD. EACH POINTS FEW, POINTS ROOD. POINTS #1199' PLENUM 1 1 1 1 1 1 1 1 #I.Ps DUCT 1 1 1 1 1 1 1 1 # 11982 FRYERS 1 6 1 6 W13R9 DUKE 2 2 4 MPB96 # 13729 NI[co 2 2 4 MPliW TOTAL FLOW 8 6 6 POINTS AMEREX PRE -PIPING DETAILS (FRYER HOOD) ANSUL FIRE SYSTEM FORRREHOF DS CHEMICAL TANKS) IL A-1.1 B'-e• FIN. CLG. HT. FRYER HOOD HOOD MOUNTED OPTIONAL ANSUL FIRE SYSTEM DETAIL II LL II AT 2 X 4 X 3 1/4- DEEP. BOX WITH 12OV, 20 AMP DUPLEX EPTACLE FOR FREEZERS AND 2 X 4 BOX WITH #8-15R RECEPTA OR DISPENSER. PRE -WIRED WITH FOR RODUCT HOLDING CABINET "FORFRYERS #10 WARE & GROUND. 8 X IMPORTANT NOTE IF FRYER DUMPFC�HEMML IT 1 ALL GAS VADUIT WITH LVE BY ECEN 2 X 4 X 3 1/4- DEEP,ELECTRICIAN IS ON THE RIGHT. THE SITEEM SHALL SWITCH THE CONTRACTOR BOX WITH 120V PRODUCT DISPENSER. PRE -WIRED 30 AMP 5-30R DUPLE( WITH # 12 WIRE, WITH GROUND 30AMP 5-30R DUPLEX RECEFMCAL TO HOOD BY FIRE SYSTEM CANTRACTOR- RECEPTAPRE-WEIR FOR FRY DUMP PRE -WIRED WITH WIR FOR E 20 AMP RECEPTACAL AT THE LEFT END. DETECTOR LINE TO BROILER OR HOODCON�TFl SWITHCAM CONTRACTLE WITH GROUND Bg 18 Is 18 ND RESTRAINING TO TE 5'-7' CABLE EYELETS PULL STATION BY FIRE SYSIEM� CONTRACTOR REDUCE TO 1' GAS PIPE OEM ELM FLOOR--- -___ —:_ __. _................ FRONT ELEVATION -UTILITIES M j L SCSI` WM FOR A�FIR t UiIBIR. UK A BNOIE 1' FLOE Will LgROff fielo OlO294W$ Ga M /1 FMPNONE q OUDIEt N r NIPPLLD BY CREWCREWNm ' 1• PIPE plop IIOE 1' X 3/4' SELL 1lDllmt X Y MPPLE INSM3/40 MM Op �3//4' GV plop WOR MRL WP POR Bf/MNO. W1F1t HOOD IIL101E GP FOR FIDBE NBWWION lW PItRlF1L HOE IOi OpSlolRIP Nr IIDBE ION 5111211 9"M 0197= CPR84BP8 m E ORU4 FRYER HOOD ENCLOSURE PANELING DETAIL CONDUIT WITH CABLE TO CABINET BY FIRE SYSTEM �1 1/4' GAS a 0 .. _ CABNET FIRE LOCATION Rrt Npuaees T-E-T TYPICAL FRYER HOOD t 3/4• X 4r &A WINE1 N 1 TYPICAL BROILER HOOD 1 BAPCIY ORCK pBOpRO.T. J t OAEBIgE71MN� W HARDWIRE —j aLXn ' B�' m 1on "/ NNON"E > TYPICAL STANDARD HOOD MOUNTED FIRE SYSTEM ARRANGEMENT NPMMYALw TYPICAL GAS APPLIANCE CONNECTION USING ONE SYSTEM TO SERVE BOTH HOODS 1 C ENCLOSURE PANELS z s LL LL 44.5 FWfFN Hoop a w w y y w N w w a u, 25 18 GA. 430 STAINLESS STEELWALLFLASHING c� lWmtFM 10 Iw BN pLY r-e• fs�'T 1•_8• DRAWING INFORMATION PPp�q.j j �L��IgIPLP.I.f �— FILL PIYR � P CAP 9D OUSE ®CR PANELS - BEE zBROLat HOOD m z z ED w m Co w z ti w z 34 18 GA. 430 STAINLESS STEEL WALL FLASHING tREEII� l�t� DE GILT WALL FLASHING DETAIL PROVUED BY GAYLORD NNNDN9 RANGE PRE�-DRLIED WITH 0}]i1ERBNNOU" ON Ur HANGING ROD CLEVICE BRACKET �il� OPTIONAL FOR HANGING ROD 1,3 " � 8 NOTE: HANGING WEIGI F- BROILER HOOD IS 450 LB FASTEN TO WALL BY HOOD INSTALLER 1.5 I ANT NorE HANGING DETAIL FOR s aMERS10N FOR BROILER/OVEN HOOD A FINISHED 0HT OF 8'8• T PANEL 1.W MECHANICAL GAS VALVE FURNISHED BY FEE SYSTEM CONTRACTOR. INSTALLED BY PLUMBER TO 1- GAS PIPE BELOW TEE ACCESS PLATE STATIC TAP (TUBE BARB FOR 3116" ID FLEX TUBETOANOMETER) STATIC TAP ENCLOSURE 15 LOCATED INSIDE THE HOOD CANOPY AT RIGHT END OF THE PLENUM WHEN LOOKING AT THE FRONT OF THEHOOD ,'AY I'RL LL WENDS MIAS RING THE SIATIC PRESSURE IN THE PLENUM AS Tr.E MEANS BY WHICH C I'ETEPMPE EXdAUST FLOW. i. STAID TAP IS ACCESSED BEHIND A PLATE LOCATED AS SHOWN IN THE DRAWNG TO T'.E LEFT. REQUIREMENTS A W,61M TES ,HAT R' ADS IN INCHES OF WATER COLUMN AND A 3/'..6 ID F.EX15C: TUBE. TO COM1ti-CT T -IF STATIC TAP TO THE MANORP-TER R-ADAG MjS" BE TA4 N AT ROOM TEMP RATURE WITH C000. FCUIPMLNT OFF & COOL. H: PROPER STATIC PRFSNI,FF READING FOR HE 1'00 ChM NPE� ,D FOH 'IS -DOD = 29 IN VES. UMONALMOUNTINGRODS BY HGDB INSTALLER HANGING FLANGE 13 PRE -DRILLED HANGING ROD CLEVICE BRACKET WITH 516" HOLES ON 6"CENTERS OPTIONAL FOR HANGING ROD 2 NOTE: RANGING WEIGHT OF FRYER HOOD IS 350 LBS FASTEN TO WALL BY HOODINSTALLER 5 HANGING DETAIL FOR FRYER HOOD STATIC TAP (NBE BARB FOR 3116" ID FLEX TUBE TO MANOMETER) STATIC TAP ENCLOSURE IS LOCATED INSIDE THE HOOD CANOPY AT RIGHT END OF THE PLENUM WHEN LOOKING AT THE FRONT OF THE HOOD GAYLORD RECC dMENOS MLOW, N. fl{; SLAll6 RLSSURE IN L r L.o.,F,S 111 �{ 'tS B J.I. T DETERMINE kF'AUST FLOW, HE SiailC LAP s accEsseD ee'IH1ND A PLATE Lou E0 As sHow:N. REQUIREMENT 1 A MANOMETER TEAT READS IN INCHES OF WATER COLUMN .AND A ,'06" 1D FI X31., TUBE TO CONNECT THE STATC TAP TO 1H MANOMETER 2 PEALING MUST RE TAKEN A ROOM T"MIFIRATURE WHH COOKINS EQUTPIENT OFF & COOL PROOEP SIAN H SSJR: READING LOP TIT 800 ',FM SPNIN IOIP IS 11.10 " I3 I 'RC. PROCEDURE TO CONFIRM HOOD EXHAUST VOLUME BK ROC Hood I Ex Fan U Fire System U HVAC Control Matrix as of 10-14-09 Reaction Action Ex Fan Electric Pwr to Cooking Equip. Mech. Gas Valve HVAC Units Make up air unit (if applicable) Comments Fan sw. turned on On On On On On Note: HVAC Units must be on before ex fan can come on Fan sw. turned off Off Off On On Off Fire system discharges On I Off Off I Off Off Slipping fan belt On 1Off On On Off Pwr to cooking equip. off wa current sensor Broken fan belt On Off On On Off Pwr to cooking equip. off via current sensor Power outage Off Off On Off Off HVAC system turned off Off Off On I Off Off SHANE HAMI TAONd1IRFAe 1717 N. DrIUVEfi�°,#431/PA, FL FLORID%t�T'.� ® F'.:02': N 75420 ��®A®enema® NIX�� PrOfessiwSl.% . C m C a3 C 0 Mechanical Englnaera EB-0008437 C 1717 N. Howard Avenue SMt- Tampa, FL 33607 (813) 251-6848 rn N > ID t E o E m m °c rn �OR Fo -a a f0 Caa) N Na c 'p /0 �a c y m� .N m T 'y U o� 'O D w � V C d C DO d t ca E (CD a: DO R--0 WOR01812:08 PM ELI w w d w > � U) z o LIJ Z U o N Y z z a if > W a se w E2 w a of LET� _ R 0 LL 0 U. m Ln W - - F Q W O O N o r- 0 I► r' zz e N � M Q� E C) AC) 0 1 i Z W : U �O Q ofir Lu C F- 0 U O❑ a w x z 7 w J Q U lL 000I w 4-0 0- U) Q O x U Eof •� O LL J Q F- Br z H 2 N LI 0 1` o LEI Of a Q 04 Lu W F- It c' Yo o >_ a Z� all 75� 0 = O LL Z LL LLI O a O o W�(nI-LU I=0 W o O x 0 z w J M 1�j W V Z L0 (O U) Lu O 0- w IY so LU W m O z J Q dD J 6 a O z lu O U) Z z O LLl LU M x � Q ❑ Z N' J r 0 W Z Q O H 0' 0 Q Copyright 2017— Drawings, W 0 specifications, notes, database, computer files, field data, and reports as instruments of service o Cn O prepared by the Design of Record. As LL I z instruments of services, these items remain the o property of the Design of Record, who shall z retain all statutory and other reserved rights, z including the copyright thereto. Any use, 3r reproduction or changes to these documents without written consent of NCA Consultants is a 0 violation of federal copyright laws. _ F- FRYER EXHAUST DUCT DETAI NOTES 2' 1. GREASE DUCT MANUFACTURED FROM ALL. 16 GAUGE ELECTROGALV STEEL 2. DUCT ASSEMBLY IS FULLY WFLDED BY THE HVAC CONTRACTOR 3. IF FIRE. RESISTANT DUCT WRAP IS NECESSARY TO MEET CODE REQUIREMENTS, IF SHALL BE PROVIDED AND INSTALLED BY HVAC CONTRACTOF NOTES B EX SU uil 6" FAN ADAPTER PLA TOTAL DUCT LENGTH APPROXIMATELY 6" LONGER THAN REQUIRED. CONTRACTOR TO CUT AS REQUIRED. CONTRACTOR TO WELD DUCT TO TRANSITION 10" ROUND TO 10" SQUARE: TRANSITION ADAPTER BY GAYLORD CONTRACTOR TO USE PROVIDED BAND OR WELD ROUND TO SQUARE TRANSITION TO DUCT COL.I..AR WHEN FITTING IS FURNISHED BY GAYLORD t\ F. TAL FAB 10" DIA. COLLAR WELDED TO F :CT EXTENSION f v GAYLORD WE:IOFD TO HOOD AT FACTORY FSS PANEL WITH 1500 F FIBERGLASS/VERMICULITE: CASKET GREASE RATED DUCT ASSY. PROVIDED BY THE HVAC CONTRACTOR BROILER EXHAUST DUCT DETAILS 1. GREASE DUCT MANUFACTURED FROI ALL 16 GAUGE ELECTROGALV STEEL 2. DUCT ASSEMBLY IS FULLY WELDED BY THE �dVAC CONTRACTOR IF FIRE RESISTANT DUCT WRAP IS NECESSARY TO MEET CODE REQUIREMENTS, IT SHALL BE PROVIDEL AND INSTALLED BY HVAC CONTRACTO j. 2'- AN ADAPTER PI..ATE. RE 8" SQ. TO RND. FITTING ADAPTER GREASE RATED DUCT ASSY. PROVIDED BY THE HVAC CONTRACTOR TOTAL DUCT LENGTH APPROXIMATELY 6" LONGER THAN REQUIRED. CONTRACTOR TO CUT AS RFQIiIRF.D. CONTRACTOR TO WELD DUCT TO TRANSITION �10" ROUND TO '10" SQUARE TRANSITION ADAPTER BY GAY._ORD �' CONTRACTOR TO USE PROVIDED BAND OR WF1 ROUND TO SOUARF TRANSIT ON TO DTCT COLLAR WHEN F1 I -ING IS FURNISHED BY GAYLORD SPANNER DUCT E SUPPOI (2 EACH) INSTALLATION INSTRUCTIONS Do. After the exhaust fan is mounted on the curb, AL y P use the following instructions to install the I TO Fan Duct Extension: OH 1. Attach the two fan discharge extension support legs to the duct extension with the nuts provided. Do not tighten. ISTRUC11ONS 2. Attach the spanner plate to the two duct I extension support legs with the bolts and nuts provided. Tighten 3. Apply a 1/8" bead of 3M Fire Stop (provided) to the exhaust fan outlet flange and the fan discharge extension flange. 4. Place the 1500 degree gasket material on one of the flanges, allowing the 3M fire to to ho it in p1tce. . LRlamp t e two flanges together and bolt together with the bolts, washers, and nuts r v tied. Ti hten bp. Arjust the upport legs so the duct extension slopes slightly towards the fan I Scl hveliNuciesttension support leg flanges to the roof with the appropriate size screws. These screws are not FRYER HOOD EXHAUST FAN DUCT EXTENSION provided by Gaylord. DRAWING INFORMATION GREASE DUCT FIELD WRAP - UP TO "0" CLEARANCE TO COMBUSTIBLES" i« ^ T- .Y0^4 . 7 � caw d LEGEND DOOR HOLE 2 ACCESS FRAME WELDED TO DUCT 3 1/4" DIA. ALL THREAD RODS 4 ACCESS COVER; 16 GA. 5 INSULATION PINS; WELDED 6 1 LAYER FIREMASTER OR UNIFRAX 7 1 LAYER FIREMASTER OR UNIFRAX 8 1 LAYER FIREMASTER OR UNIFRAX 9 SPEED CLIPS 10 IALUMINUM TAPE EDGES 11 ISPOOL PIECES FOR THREADED RODS 12 1/4" DIA. WING NUTS 13 16GA. SHEET METAL DUCT (FULLY WELDED WATER TIGHT) 14 1ST LAYER LAYER FIREMASTER OR UNIFRAX LONGITUDINAL BUTT JOINT INNER LAYER, BUTT JOINT ON OUTER LAYER 15 3/4" (19mm) WIDE FILAMENT TAPE 16 2ND LAYER LAYER FIREMASTER OR UNIFRAX OR APPROVED EQUIVALENT 17 STEEL BANDING 112" WIDE MIN. TYP. FOR PERMANENT FASTENING NOTES: 1. BANDING MATERIAL, 3/4" WIDE, MINIMUM 0.015" THICK, CARBON STEEL FOR CONSTRUCTION REQUIREMENTS OF ZERO CLEARANCE TO COMBUSTIBLES OR 1 HR. RATINGS. STAINLESS STEEL BANDING IS USED FOR 2 HR. REQUIREMENTS. 2. FIREMASTER OR UNIFRAX, 1-1/2" THICK, 24" OR 48" WIDE, 300" STANDARD LENGTH (2 LAYERS) 6 LBS PER CUBIC FT TO BE UTILIZED. 3. HOLD INTERIOR WRAP OF INSULATION USING 1" WIDE FILAMENT TAPE (NO. 898) MANUFACTURED BY 3M COMPA�7�Y�- 4. SEAL CUT EDGES OF BLANKET WITH ALUMINUM V917 T7PZr-� V FULLY WELDED B.I., 16 GA. GREASE RATED EXHAUST PLAN. RISER SHALL BE LIGHT INSPECTED LAYING ON FULLY PREPARE FOR SCHEDULED INSPECTION. HVAC CONTRACTOR SHALL VERIFY TEST PRIOR TO SC THE USE OF U.L. LISTED PREFABBED DUCT BY CAPTI CORRECTLY MAY BE EXEMPT FROM LIGHT INSPECTION RM NOTE: INSTALLATION METHOD MAY VARY WHERE "39ORIFW'-BRIER 615 PLUS" FIREMASTER O 1 HR. FIRE WRAP ( "0" CLEARANCE TO COMBUSTIBLES I O N DETAIL riLLAT SHANE H l•��ITtQ 17xVORDI�TA:MPA, FL FO N0Ce�CN .,N 75420 E OF 0010, -.l 0 R10P�?\��w< 0NAB1 PLAN VIEW IS NOT N•C•A C O N S U L T A N T S/ G R O U P 4585 140TH AVE. NORTH, SUITE #1001 CLEARWATER, FLORIDA PHONE: (877) 530-0078 CALL NCA MARKETING FOR PRICING NCA JOB# 17-394 R. Wulberr>< r ; Architect W. O O AA - 0003433 lic W 0 (904)329-2510 tel m 0 robertowulbem.net a C 80 -0 U a) d C m ��IB9/�Ig a Pfvfessfon9114 kw. 2 o Mechanical Engineers -p EB-0006437 r= m 1717 N. Howard Avenue Tampa, FL 33607 (813) 251-6848 uJ N �> (D .- la V w 0 m E o 0) a � oc CD m m� m at) v, N� c Co C rn a) 0 C o) 4 a, c N O -Q 5 a 0 0 c a c m t m E E E N 0 °m 8/30/2018 12:09 PM rn S � Sw w w a1 w � s > 0 Z Z 0 0a� t)J U C) !n IX) Y S2 z LU re aS2 f w Y w o D re Lu O LL o U. W r ~ Oo m 0 n 0 0 i 5 n U U S Ni O O Et Z W U Z Q U w a H UJ Of x a° a o Of 0 U O 0 EL LU Z....r......r� LL J J U w A^ c a to ¢ O U o Jy ¢ Cl)Z I KCN W LI YII O tL O CN a04 UU O O Z Y �p n '^CJ O Z of LL U. aLLI= Y }} Z a OOP �F O j O LL^I V) =01 � (.5 0 O ♦'Lu O li Lf. O J Z M R 1�j W Z 00 LO w W V to (� - U 0 3- Ir a w O z ' THC SC PLANS AND ALL PROPOSrzD WOW W ARE SUBJECT TO ANY C0P.RECTICN,lS Co Co REQUIRED BY FIELD INSPECTORS TI co w MAY BE NECESSARY IN ORM DTO 0 COMPLY WITH ALL APPLICABLE COTE;;. Z a � }1 z, Z 0 ¢ ID 6'I'. a Z m' w', UU iLL .. FILE COPY z Z 3I O LU LU Q W 2 In LU W Z O U N N r, -.1 W H W O' H In © Copyright 2017- Drawings, ° W o specifications, notes, database, computer files, 2 O field data, and reports as instruments of service Of N prepared by the Design of Record. As Z instruments of services, these items remain the o property of the Design of Record, who shall Z retain all statutory and other reserved rights, Z including the copyright thereto. Any use, reproduction or changes to these documents _ without written consent of NCA Consultants is a violation of federal copyright laws. _ H