ProjectiName: BURGER KING at KITTERMAN ROAD
Proiect,Address: 6598 SOUTH U.S. HIGHWAY 1 - ST. LUCIE COUNTY, FLORIDA 34952
Permit #: 1712-0227 Occupancy Type: A-2 Construction Type: V B
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Sd6mit (2) copies for residential, (3) copies for commercial with all permit applications involvingthe following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit 4'IP23-wd2
Co Any non-residential structure.,
* Note: Form not required for interior renovations provided that no exterior structural elements are affected, and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that Sixth
1. DESIGN CODE: Florida Building Code dition using ASCE 7-10
2. Structure Designed as (check one): x Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B x C D
4. Dgsign Wind Velocity 161 mph ASD x LRFD End Zone Width: 41-011 ft
5. Mean Roof Height 1 V-10° ft Roof Pitch: 0.25 :12 Parapet: 3'-6"/7'-2" ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
+28/--57 +52/-95 +52/-95 +52/-56 +52/-69 N/A
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. DI sign Loads: Floor: 100 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not:
9. Is'A Continuous Load Path Provided? x Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes
I.
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forc4specified: �,,j n
David L. Webb FL COA #791
:�OQJ G •IVs • Print Name Cert # & Co. Cert Auth.
%
N . 1 Atlantic Engineering Services of Jacksonville
Signat r nd ea12%i5P
- 0 STATE OF
'.� 40RIO•P••� ,:
Revised 07 •• ••••.,:
6501 Arlington Expressway, Bldg B, Suite 201 Jacksonville, FL 32211
Company Name & Address