HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEI r "li�(w3, 4' Planning &Development Services Department f/. F �5,... 'A Building & Code Regulations Division • 2300 Virginia Avenue, Fort Pierce, FL 34982 ..a , A 2-1�5e- ' E.I.: r UPCertification for Design Load Compli '. ce ProjectiName: BURGER KING at KITTERMAN ROAD Proiect,Address: 6598 SOUTH U.S. HIGHWAY 1 - ST. LUCIE COUNTY, FLORIDA 34952 Permit #: 1712-0227 Occupancy Type: A-2 Construction Type: V B INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Sd6mit (2) copies for residential, (3) copies for commercial with all permit applications involvingthe following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit 4'IP23-wd2 Co Any non-residential structure., * Note: Form not required for interior renovations provided that no exterior structural elements are affected, and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that Sixth 1. DESIGN CODE: Florida Building Code dition using ASCE 7-10 2. Structure Designed as (check one): x Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B x C D 4. Dgsign Wind Velocity 161 mph ASD x LRFD End Zone Width: 41-011 ft 5. Mean Roof Height 1 V-10° ft Roof Pitch: 0.25 :12 Parapet: 3'-6"/7'-2" ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): +28/--57 +52/-95 +52/-95 +52/-56 +52/-69 N/A Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. DI sign Loads: Floor: 100 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not: 9. Is'A Continuous Load Path Provided? x Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes I. DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forc4specified: �,,j n David L. Webb FL COA #791 :�OQJ G •IVs • Print Name Cert # & Co. Cert Auth. % N . 1 Atlantic Engineering Services of Jacksonville Signat r nd ea12%i5P - 0 STATE OF '.� 40RIO•P••� ,: Revised 07 •• ••••.,: 6501 Arlington Expressway, Bldg B, Suite 201 Jacksonville, FL 32211 Company Name & Address