HomeMy WebLinkAboutWALL SECTIONLED PARAPET LIGHT'G. BAND
LED UPLIGHTING
PRE -FIN. ALUMIN. LIGHT BAND \
FLASHING with CONT. CLEAT
CONT. TAPE MASTIC (OVER SILL SCREED)
14-10 x 2" MASONRY SCREW FSTNR. at 24" O.C.
with TAPE SEALER EA. SIDE of FLEX MEMBRANE
STUCCO FINISH. SYS.
REFER TO CONT. PVC SILL SCREED
ELEVATIONS FLEX MEMBRANE �\
LONG LIFE LAP-TEK FSTNR'S. at 6" O.C.
DO NOT INSTALL THRU PANEL RIB
TRI-BEAD SEALER TOP of CLOSURE
& TOP OF FLEX MEMBRANE �—
OUTSIDE CLOSURE PANEL with URETHANE
SEALANT at ENDS, PANEL RIBS & LAPPING
CLOSURE TABS (SEAL ALL VOIDS) /
" EXT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
AIR/WATER BARRIER
STANDING SEAM ROOF'G. SYS.
LOW-FOATING CLIP
CONT. t' EXT. PLYWD NAILER
SELF-TAPP'G. PANCAKE PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
HEAD FSTNR. at 12" O.C.
(SEE STRUCT.)
NON -SKINNING BUTYL SEALANT
BTWN. PANL RIBS (TYP.) —�
PRE -FIN. ALUMIN. EAVE
TRIM with DRIP EDGE
CONT. P.T. 2x4 FASCIA
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
CONT. 3" PVC SOFFIT VENT
8" EXT. PLYWD. SHEATH'G.
STUCCO FINISH SYS.
AIR/WATER BARRIER
(2) SELF-TAPP'G. CONT. P.T. 2x8
TYPE'A' FSTNR'S. (SEE STRUCT.)
CONT, CAULK JT.
HORIZ. REVEAL (SEE ELEV'S)
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
STUCCO FINISH SYS.
CONT. TAPE MASTIC (OVER SILL SCREED)
CONT. PVC SILL SCREED
PRE -FIN. ALUMIN. FLASHING
BTWN. BRICK and STUCCO
1" EXTERIOR THIN BRICK
TOP COURSE - TYP.
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPECS. (SEE ELEV'S.)
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH BRICK (6" min.)
q0 Projects Current\1667.07 BK-A29752 (Kitterman St Lucie Cc) (576)\1667_07 A-6 12 Wall Sections.dwg, 12/4/2017 6:21:53 PM
FALSE PARAPET CAP FLASH'G
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and
OVER TOP OF PARAPET
LONG -LIFE SELF-TAPP'G FTNR.
with WASHER (TYP. EA. RIB)
SELF-TAPP'G. TYPE'A' FSTNR'S.
with WASHER and TRI-BEAD TAPE
SEALER (TYP.)
CONT. P.T. 2x8 (SEE STRUCT.)
MANUF'S. STD.
ROOF'G. TRANSITION
USSES at 24" O
(SEE STRUCT.)
" GWB (MMR) ON g' CFSF FURRING at
16" O.C. TO U/S OF ROOF DECK.
J" RIGID INSUL. BTWN. FURR'G STRIPS
CONT. P.T. 2x8 LEDGER and
JOIST HANGER (SEE STRUCT.)
CHAIR RAIL (SEE DECOR)
%" GWB (MMR)
RIGID INSUL. BTWN. J" CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS. (SEE DECOR)
CONT. FRP J-CHANNEL (CAULKED)
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
REFER TO
ELEVATIONS
„a $
CONT. CONC. FTG. (SEE STRUCT.)
a �
2 DINISNG (SOUTH) ELEVATION
SCALE: 3/4" = 1'-0" at 24"x36"
SINGLE PLY ROOF SYS.
RIGID POLYISO. INSUL.
(5" thk. MIN.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
a
LED PARAPET LIGHT'G. BAND
LED UPLIGHTING
FALSE PARAPET CAP FLASH'G.
PRE -FIN. ALUMIN. LIGHT BAND
SNAP -ON PRE -FIN. MTL.
FLASHING with CONT. CLEAT
PARAPET CAP FLASHING,
SLOPE to ROOF
CONT. TAPE MASTIC (OVER SILL SCREED)
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
14-10 x 2" MASONRY SCREW FSTNR. at 24" O.C.
with TAPE SEALER EA. SIDE of FLEX MEMBRANE
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
STUCCO FINISH. SYS.
CONT. MTL. CLEAT FASTEN
CONT. PVC SILL SCREED
at 8" O.C. (TYP. EA. SIDE)
FLEX MEMBRANE
EXTEND ROOF'G. UP and
�.
OVER TOP OF PARAPET
LONG LIFE LAP-TEK FSTNR'S. at 6" O.C.
DO NOT INSTALL THRU PANEL RIB
LONG -LIFE SELF-TAPP'G FTNR.
with WASHER (TYP. EA. RIB)
TRI-BEAD SEALER TOP of CLOSURE
& TOP OF FLEX MEMBRANE
SELF-TAPP'G. TYPE W FSTNR'S.
with WASHER and TRI-BEAD TAPE
OUTSIDE CLOSURE PANEL with URETHANE
r
SEALER (TYP.)
SEALANT at ENDS, PANEL RIBS & LAPPING
CLOSURE TABS (SEAL ALL VOIDS) /
CONT. P.T. 2x8 (SEE STRUCT.)
�' EXT. PLYWD. ROOF
MANUF'S. STD.
SHEATH'G. (SEE STRUCT.) /
ROOF'G. TRANSITION
AIR/WATER BARRIER
/
STANDING SEAM ROOF'G. SYS.
LOW-FOATING CLIP /
CONT. 8" EXT. PLYWD NAILER
SELF-TAPP'G. PANCAKE PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
P-ENG'D. W D
USSES at 24" O. —
HEAD FSTNR. at 12" O.C.
(SEE STRUCT.)
r.
(SEE STRUCT.)
;r'.
NON -SKINNING BUTYL SEALANT
BTWN. PANL RIBS (TYP.)
(2) SELF-TAPP'G. CONT. P.T. 2x8
PRE -FIN. ALUMIN. SAVE
TRIM with DRIP EDGE
CONT. P.T. 2x4 FASCIA
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
CONT. 3" PVC SOFFIT VENT
" EXT. PLYWD. SHEATH'G.
STUCCO FINISH SYS.
AIR/WATER BARRIER
TYPE'A' FSTNR'S. (SEE STRUCT.)
/ CONT. CAULK JT.
STUCCO FINISH SYS.
CONT. FLUID APPLIED
AIR/WATER BARRIER
(SEAL OPENINGS &
PENETRATIONS - TYP.)
FLASHING TAPE
OVER DRIP EDGE
PVC DRIP EDGE FLASHING
CONT. CAULK JT.
PRE -FIN. ALUMIN. FLASHING
BTWN. BRICK and STUCCO
1" EXTERIOR THIN BRICK
TOP COURSE - TYP.
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPEC'S. (SEE ELEV'S.)
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH BRICK (6" min.)
TYPICAL ALL SECTIONS:
1. PROVIDE INSULATION (R—VALUE
AS PER ENERGY CALC'S.) FROM
FLOOR TO ROOF DECK IN ALL
EXTERIOR WALLS.
2. PROVIDE GYPSUM WALL BOARD
(MOLD/MOISTURE
RESIST.)SUBSTRATE FROM FLOOR
TO ROOF DECK AT ALL WALLS
WITH EXPOSED ROOF TRUSSES.
3. REFER TO INTERIOR DECOR
SCHEDULE FOR ALL INTERIOR
FINISHES.
4. REFER TO EXTERIOR DECOR
SCHEDULE FOR ALL EXTERIOR
FINISHES.
R. Wulbern
t Ui Architect PA
a CL U AA-0003433 lie.
to U (904)329-2510 tel .
0) U robert@wulbem.net.
a 'c
U O0
a�i m
c m
1L c
to
�
c
AWNINGS AND FRAMES PER
0
APPROVED SUPPLIER. PROVIDE
BLOCKING AS REQUIRED PER LOCAL
m
CODES. COORDINATE LOCATION
WITH MANUFACTURER.
m�
v
�
N
E
CU
N
oCm
c
rn
�
N
(D
0)
L
cc
L
ca
N
0)
-O
0)
0)
0
�
N
y�
c
d
@
GL)
0
N
rn
T'y
U
y
c
o
y
.o
w
c
�
U
n�
c
S
s
�
m
REFER TO J
'w
ELEVATIONS
F
°
o
�— CONT. P.T. 2x8 LEDGER and
JOIST HANGER (SEE STRUCT.)
" RIGID INSUL. BTWN. FURR'G STRIPS
" GWB (MMR) ON J" CFSF FURRING at
16" O.C. TO U/S OF ROOF DECK, RETURN
GWB INTO WINDOW OPEN'G. (TYP.)
S.F. WINDOW HEAD FASTEN
per PRODUCT APPROVAL
INSUL., IMPACT RATED, LOW-E GLAZING
S.F. HORIZ. INTERMEDIATE MULLION
INSUL., IMPACT RATED, LOW-E GLAZING
SINGLE PLY ROOF SYS.
RIGID POLYISO. INSUL.
(5" thk. MIN.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
CHAIR RAIL BEYOND (SEE DECOR)
WINDOW SILL (SEE DECOR)
%" GWB (MMR)
RIGID INSUL. BTWN. J" CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS.
THESE PLANS AND ALL PROPOSED WORK
.:ARE SUBJECT TO ANY CORRECTIONS
CONT. FRP J-CHANNEL (CAULKED) REQUIRED BY FIELD INSPECTORS THAT
TILE BASE (SEE DECOR) Bri NECESOARY IN ORDER TO.
00-4fLY4YITHPL,�p�{ICA CDDESr'
TILE FLOOR (SEE DECOR) `--=--
CONC. SLAB withVAPORRETARDER e
CMU STEM WALL (SEE STRUCT.)
Qvzo
CONT. CONC. FTG. (SEE STRUCT.)
DINING WINDIC
SCALE: 3/4" = 1'-0" at 24
O� _
SOUTH) ELEVATION
z
W
x
F-
,��.-OF FG,O,pi
S
A..
D ARCS
12/4/2017 6:22 PM
s
w
a
C
W
z
a
d
_0
fn
U)
Ic
z
z
N
>
LU
Q
Y
Y
IL
0
W
LL
m
m
n
r
a
0
0
a �
g N
o
ly
0
0
z
W
�1
z
Y
W
W
ccQ
CK
0
U
O 0
(L
0 goldco
VERTICAL
I J-,TWUCTO V' nl
IM�1Ji�M xl'.
V
'A.;
N
N
Q
z
Q
N
OO
W
Y
In
v.
CO
a
('
Ix
O
��S
Oro
W
W
O
:)
Ortl
m�zU)
op
J
N
1
U)
O
U
W
V)
A-6
LED PARAPET LIGHT'G. BAND
LED UPLIGHTING
PRE -FIN. ALUMIN. LIGHT BAND
FLASHING with CONT. CLEAT
REFER TO
ELEVATIONS
CONT. TAPE MASTIC (OVER SILL SCREED) -
CONT. PVC SILL SCREED -
PRE -FIN. ALUMIN. FLASHING
BTWN. BRICK and STUCCO
REFER TO h
ELEVATIONS
(2)" ADHESIVE ANCHORS
with 5" EMBEDMENT
REFER TO PLANS &
ELEV'S FOR DEPTH
WEATHER TIGHT LAMP
(COORD. w/ CANOPY MANUF.)
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPECS. (SEE ELEV'S.)
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH BRICK (6" min.)
a Drive\0 Projects Current\1667.07 BK-A29752 (Kitterman St Lucie Cc) (576)\1667 07 A-6 12 Wall Sections.dwg, 12/4/2017 6:22:16 PM
FALSE PARAPET CAP FLASH'G
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and
OVER TOP OF PARAPET
MANUF'S. STD.
ROOF'G. TRANSITION
.USSES at 24" O
(SEE STRUCT.)
CONT. P.T. 2x8 LEDGER
and JOIST HANGER
(SEE STRUCT.)
SINGLE PLY ROOF SYS.
RIGID POLYISO. INSUL.
(5" thk. MIN.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
T" GWB (MMR-SAG RESISTANT)
CLG. ON GWB SUSPENSION SYS.
GWB (WATER
RESISTANT) from 24" AFF UP.
2x6 or 2x4 P.T. FRAMING at 16" O.C.
(SEE PLAN FOR WALL THICKNESS)
UNFACED BATT INSUL. (R-15 min.)
DUROCK SHEATHING to 24" AFF
TILE WALL FINISH (SEE DECOR)
2x P.T. SILL PLATE
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
e°• ° s e• a.
CONT. CONC. FTG. (SEE STRUCT.)
a •
A JOILET (SOUTH) ELEVATION
SCALE: 3/4" = 1'-0" at 24"x36"
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
MOLDED EPS INSUL. CORNICE
with STUCCO FINISH. PROVIDE
CONT. BLOCK'G. AS REQ'D.
CONT. CAULK JT. with BACKER ROD
8" EXT. PLYWD. SHEATH'G.
NICHIHA PANEL SYS.
AIR/WATER BARRIER (WRAP & SEAL
OPENINGS & PENETRATIONS - TYP.)
CONT. (2) 2X6 BLOCKING at
SIGN MOUNTING POINTS
with LUS26-2 EA. END
MANUF'S. STD. HORIZ.
EXPANSION JTJ FLASHING SYS.
CONT. P.T. (2) 2x8 TOP
PLATE (SEE STRUCT.)
S-2
8" CMU WALL (SEE STRUCT.)
Z" X 6" LAG BOLT INTO (2)
2x8's with e" PLYWD. FILLER
REFER TO PLANS &
ELEV'S FOR DEPTH
WEATHER TIGHT LAMP
(COORD. w/ CANOPY MANUF.)Lj
3 t' CFSF at 24" O.C. CLIP --_ _-_—
TO CMU (SEE STRUCT.)
CONT. CAULK JT. J
(1) PT2x6 NAILER TOP WITH--
3/4" DIA ADHESIVE ANCHORS
AT 24" OC WITH 6 3/4" EMBED.
(TYP. EA. END)
NICHIHA CORNER TRIM (TR-IG) -
TYP. at ALL OUTSIDE CORNERS
NICHIHA WALL PANEL SYSTEM over
AIR(WATER BARRIER and J" EXT.
PLYWD. SHEATH'G. on 3" CFSF — -
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
ROOF'G. MANUF'S. STD. PARAPET WALL
VENT. CITY. TO BE DETERMINED BY THE
UNITS FREE AREA DIVIDED BY REQ'D.
FREE AREA NOTED ON ROOF PLAN.
EXTEND ROOF'G. UP and OVER TOP OF PARAPET
PRE-ENG'D. WOOD TRUSSES
at 24" O.C. (SEE STRUCT.)
MANUF'S. STD.
ROOF'G. TRANSITION
8" EXT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
2x8 FRAMING
at 24" O.C.
CONT. 2x8 LEDGER and JOIST
HANGER (SEE STRUCT.)
SIMPSON LUS24 HANGER
EACH END EACH RAFTER
ATTACHED WITH (4) 10d NAILS
TO NAILER AND RAFTER
CONT, 3" PVC
r SOFFIT VENT
STUCCO FINISH over
AIR/WATER BARRIER and P
EXT. PLYWD. SHEATH'G.
J
OPEN
NICHIHA CORNER TRIM
(TR-1 G) - TYP. at ALL
OUTSIDE CORNERS
NICHIHA WALL PANEL
SYSTEM over
AIR/WATER BARRIER
and g" EXT. PLYWD.
SHEAT TG. on 3 B" CFSF
REFER TO
ELEVATIONS
92 le
�N
N
-IN SIN
LO
(-4 I —
12' 24„
93„
MANUF'S. STD.
ROOF'G. TRANSITION
SINGLE PLY
ROOF SYS.
TRUSSES at 24" O.C.
(SEE STRUCT.)
RIGID POLYISO. INSUL.
(5" thk. MIN.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
AIR/WATER BARRIER
(WRAP & SEAL
OPENINGS &
YNETRATIONS - TYP.)
CONT. FLUID APPLIED AIR(WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
(1) PT2x6 NAILER TOP WITH (2)
3/4" DIA ADHESIVE ANCHORS
AT 24" OC WITH 6 3/4" EMBED.
(TYP. EA. END)
SIMPSON LUS24 HANGER EACH END
EACH RAFTER ATTACHED WITH (4)
10d NAILS TO NAILER AND RAFTER
CONT, CAULK JT.
CONCRETE PAVERS OVER 1" SAND
BED ANDS" BASE MATERIAL
(COMP. LBR-100). COORD. w/ CIVIL.
TRAFFIC SEALANT & BACKER
ROD w/ PVC JOINT COVER
SLOPE AWAY
FROM BLDG.
REFER TO DECOR PACKAGE
FOR PAINTED FINISH COLOR
FOR TRUSSES, CONDUITS,
ROOF DECK, ETC.
3" CFSF at 16" O.C. (SEE STRUCT.)
CONT. CAULK JT. (TYP. BOTH SIDES)
INSUL.
TT
RIGID INSUL. BTWN. FURR'G STRIPS
gGWB (MMR) ON J" CFSF FURRING at
16" O.C. TO U/S OF ROOF DECK. RETURN
GWB INTO WINDOW OPEN'G. (TYP.)
S.F. WINDOW HEAD FASTEN
per PRODUCT APPROVAL
INSUL, IMPACT RATED, LOW-E GLAZING
S.F. HORIZ. INTERMEDIATE MULLION
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
odAY BE NECESQARY IN ORDER TO,
COMPLY WITH kiLAPI
tICA CODES,
INSUL., IMPACT RATED, LOW-E GLAZING
S.F. WINDOW SILL with SILL
RECEPTOR, SET IN BED of SEALANT
and FASTEN per PRODUCT APPROVAL
CONT. SANDED CAULK JT.
TILE FLOOR (SEE DECOR)
. .
'.•D D • r• • a 0 • ' > • .• s a
> � e > '' D e ' D s � D D e e e D � De • p .. • '' • " - ' , � . • . •'e. s ., : a � CONC. SLAB with VAPOR RETARDER
i r..e e. • D r b e ..
CMU STEM WALL (SEE STRUCT.)
EXP. JT.
Q O
Q
CONT. CONC. FTG. (SEE STRUCT
LL
z
SENTRY (SOUTH) ELEVATION Z
SCALE: 3/4" = 1'-0" at 24"x36" 9
O
w
x
F_
R. Wulbern
t oArchitect PA
y O- AA .0003433 Ile e
NU (904)329-2510 tel "
0) U robert@wulbem.net e
•�EOF F(�R/
P'
33 �•~
'ARG�
D
12/4/2017 6:22 PM
S
J
$qN
J
L
F
W
w
d
w
C
GN
�
w
IL
z
Z
CL:0
o
�
0
W
O
(n
N
Y
z
z
N
LU
2:0
LU
m
im
W
~
o
0
0
(O
0
0
N
G
n
U
U
N
M
�
O
x
Of
< o
0
z
W %p
Z
Y
m 1--
Of
0
=
U
O 0
LL
LU
w
x
U
z
LL
J
J
U
LL
5
w
a -
to
to
3
x
U_
0
O
LL
F-
x
F-
X
w
x
O
L
U
O
a-
o'
o_
W
w
x
0
O
W
O
LL
a
z
of
O
w
J
0
z
0
w
U
0
0
a
W
Of
0
z
4
0
w
U)
D
w
an
O
0
z
¢
2
1'
0
a
J
L
M
tl}
L�zl
z
W
u-
z o
O
,
Q
U
m
�
Lij
z
LU
W
LU
Z
S ZZZ
A-7
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
REFER TO
ELEVATIONS Y
MOLDED EPS CORNICE
with STUCCO FINISH. PROVIDE -
CONT. BLOCK'G. AS REQ'D.
CONT. CAULK JT. with BACKER ROD -
PRE-ENG'D. WOOD TRUSSES
at 24" O.C. (SEE STRUCT.)
MANUF'S. STD. HORIZ. _
EXPANSION JTJ FLASHING SYS.
CONT. P.T. (2) 2x8 TOP
PLATE (SEE STRUCT.)
NICHIHA PANEL SYS. -
J" EXT. PLYWD. SHEATH'G. -
8" CMU WALL (SEE STRUCT.) -
AIR/WATER BARRIER
(WRAP & SEAL OPENINGS -
& PENETRATIONS - TYP.)
3 5' CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
" X 6" LAG BOLT INTO (2)
2x8's with B" PLYWD. FILLER
REFER TO PLANS &
ELEV'S FOR DEPTH
WEATHER TIGHT LAMP
(COORD. w/ CANOPY MANUF.)
NICHIHA PANEL SYS.
8" EXT. PLYWD. SHEATH'G.
AIR/WATER BARRIER
(WRAP & SEAL OPENINGS
& PENETRATIONS - TYP.)
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOPG. UP and OVER TOP OF PARAPET
ROOF'G. MANUPS. STD. PARAPET WALL
VENT. CITY. TO BE DETERMINED BY THE
UNITS FREE AREA DIVIDED BY REQ'D.
FREE AREA NOTED ON ROOF PLAN.
MANUF'S. STD.
ROOF'G. TRANSITION
S" EAT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
USSES at 24" O.
(SEE STRUCT.)
CONT, P.T. 2x8 LEDGER and
JOIST HANGER (SEE STRUCT.)
CONT. CAULK JT. J / --
8" EXT. PLYWD. SHEATH'G. -
NICHIHA SOFFIT SYS.
AIR/WATER BARRIER
CONT. CAULK JT.
NICHIHA CORNER TRIM
(TR-1 G) - TYP. at ALL
PROVIDE BLOCKING BETWEEN OUTSIDE CORNERS
TRUSSES ® 24" O.C. VERT. _-
NICHIHA PANEL SYS. (BEYOND)
STAINLESS STL. SILL --
2x4 FRAMING 0 16" O.C. 1" EXTERIOR THIN BRICK
TOP COURSE - TYP. ♦77
•i
PRE-ENG'D. WOOD
TRUSS PARAPET NICHIHA WALL PANEL SYS. TO BE CONT. FLUID APPLIED PENINAIR/WS &
FRAMING at 24" O.C. APPLIED IN STRICT ACCORDANCE BARRIER (SEAL OPENINGS.)
W/ MANUFACTURERS REQUIREMENTS PENETRATIONS -TYP.)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPEC'S. (SEE ELEV'S.)
ROOF TRUSSES CONT. CAULK JT.
(REF. FRAMING 2x6 BETWEEN TRUSSES
PLAN WITH SIMPSON JOIST CONC. BARRIER CURB
HANGER AT EACH END.
CORNER TRIM ATTACHED PAVING (SEE CIVIL) •
PER MFR. REQUIREMENTS
4".
STUCCO FINISH SYS. TO BE
CORNER TRIM ATTACHED --- 2 _0 APPLIED IN STRICT ACCORDANCE D D D 0
PER MFR. REQUIREMENTS (MIN') W/ MANUFACTURERS REQUIREMENTS
NICHIHA WALL PANEL SYS. • •
TO BE APPLIED IN STRICT
ACCORDANCE W/
MANUFACTURERS REVS.
TYPICAL PLAN AT
,TOWER RETURN WALL
SCALE: 3/4 1'-C at 24"x36"
SINGLE PLY ROOF SYS.
MANUPS. STD.
ROOF'G. TRANSITION
SINGLE PLY
I— ROOF SYS.
J" RIGID INSUL. BTWN. FURR'G STRIPS ACT CLG
FRP SY.S ON J" GWB (MMR) over j" CFSF
FURRING at 16" O.C. TO U/S OF ROOF DECK.
RETURN GWB INTO WINDOW OPEN-G. (TYP.)
S.F. WINDOW HEAD FASTEN
per PRODUCT APPROVAL
S.F. WINDOW SILL FASTEN
per PRODUCT APPROVAL
SELF -CLOSING DRIVE -THROUGH
WINDOW AS SPECIFIED ON SHT. A-10
FASTEN per PRODUCT APPROVAL
CAULK PERIMETER BOTH SIDES
STAINLESS STL. SILL SET
IN BED OF SEALANT
GWB (MMR) T-O" AFF }
SILL HEIGHT
RIGID INSUL. BTWN. J" CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS.
CONT. FRP J-CHANNEL (CAULKED)
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
CONT. CONC. FTG. (SEE STRUCT.)
'D/T WINDOW (NORTH) ELEVATION
SCALE: 3/4' = 1'-0" at 24"06"
RIGID POLYISO.
INSUL. (5" thk. MIN.)
PLYWD. ROOF
SHEATH'G.
(SEE STRUCT.)
FALSE PARAPET CAP FLASH'G.
LED PARAPET LIGHT'G. BAND SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
LED UPLIGHTING SLOPE to ROOF
PRE -FIN. ALUMIN. LIGHT BAND WRAP FLEXIBLE FLASHING
FLASHING with CONT. CLEAT OVER TOP of PARAPET
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
REFER TO J CONT. MTL. CLEAT FASTEN
ELEVATIONS at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and
OVER TOP OF PARAPET
CONT. HINGE
T-6" x 6-6" PRE -FIN. ALUMIN.
SINGLE PLY ROOF SYS.
RIGID POLYISO. INSUL.
(5" thk. MIN.)
MANUF'S. STD.
ROOPG. TRANSITION PLYWD. ROOF SHEATH'G.
141- (SEE STRUCT.)
USSES at 24" 0
(SEE STRUCT.)
CONT. P.T. 2x8 LEDGER
and JOIST HANGER
(SEE STRUCT.)
ACT CLG.
HOLD -OPEN ROD
(BOLTED BOTH ENDS)
+:r
ANGLE BRACKET FASTEN TO CMU
HORIZ. REVEAL (SEE ELEV'S)
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.) THESE PLANS AND ALL PROPOSED WORK
STUCCO FINISH SYS. ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT.
k MAY BR NECESSARY fN .ORDAR TO Jq
CONT. TAPE MASTIC (OVER SILL SCREED) x COMPLY Wrrm -M-L-AppLicAr
.14 CODE$ ,
CONT. PVC SILL SCREED
PRE -FIN. ALUMIN. FLASHING 58e GWB (MMR)
BTWN. BRICK and STUCCO
1" EXTERIOR THIN BRICK RIGID INSUL. BTWN. J" CFSF
TOP COURSE - TYP. FURRING STRIPS at 16" O.C.
CONT. FLUID APPLIED AIR/WATER FRP PANEL SYS.
BARRIER (SEAL OPENINGS & CONT. FRP J-CHANNEL (CAULKED)
PENETRATIONS - TYP.)
TILE BASE (SEE DECOR)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPECS. (SEE ELEV'S.) TILE FLOOR (SEE DECOR)
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH BRICK (6" min.)
CONIC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
3
CONT. CONC. FTG. (SEE STRUCT.)
e •
05
KITCHEN (SOUTH) ELEVATION
SCALE: 3/4" = 1'-0" at 24%36"
R. Wulbern
Architect PA
AA-0003433 Ilc
NU (904)329-2510 tel
N U robert@wulbem.net
P '!
33 ?~
D .ARC��
12/4/2017 6:22 PM
rui
w
W
En
z
CLa
o(noo
!n
ir
z
z
N
�
Q
LU
Y
Y
lL
O
of
7
>LL
CCD
m
m
W
r`
TIN
o
1
d _
n
u
U
N
In
O
Er
< o
C
A
C] 1
z
w
z
U
z
leS
W
cy
_
a
M
❑
U
Q ❑
a
0
w
x
1n
z
LL
LL
J
J
U
U
w
a.
co
x
U_
x
IY
O
LL
r
x
I-
x
I —
a
w
x
0
0
L
(n
O
EL
a
w
F
O
z
z
O
LL
it
a
z
Of
O
w
J
O
x
z
0
w
U
0
O
a-
a
of
IY
O
0
z
0
W
1n
0
W
m
0
O
z
❑
a
J
1
Ln
z
w
❑
LL
z
O
z
O
U)
W
O
w
w
_
(n
t J
J
0
w
` Q
A
-
Wkil
�C �vz
z
A8
K
e Drive\0 Projects Current\1667.07 BK-A29752 (Kiaerman St Lucie Co) (576)\1667 07 A-6 12 Wall Sections.dwg, 12/4/2017 6 2237 PM
LED PARAPET LIGHT'G. BAND
LED UPLIGHTING
PRE -FIN. ALUMIN. LIGHT BAND
FLASHING with CONT. CLEAT
CONT. TAPE MASTIC (OVER SILL SCREED)
14-10 x 2" MASONRY SCREW FSTNR. at 24" O.C.
with TAPE SEALER EA. SIDE of FLEX MEMBRANE
STUCCO FINISH. SYS.
CONT. PVC SILL SCREED
FLEX MEMBRANE
LONG LIFE LAP-TEK FSTNR'S. at 6" O.C.
DO NOT INSTALL THRU PANEL RIB
TRI-BEAD SEALER TOP of CLOSURE
& TOP OF FLEX MEMBRANE
OUTSIDE CLOSURE PANEL with URETHANE
SEALANT at ENDS, PANEL RIBS & LAPPING
CLOSURE TABS (SEAL ALL VOIDS)
" EXT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
AIR/WATER BARRIER
STANDING SEAM ROOF'G. SYS.
LOW-FOATING CLIP
CONT. J' EXT. PLYWD NAILER
SELF-TAPP'G. PANCAKE PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
HEAD FSTNR. at 12" O.C.
(SEE STRUCT.)
NON -SKINNING BUTYL SEALANT
BTWN. PANL RIBS (TYP.)
(2) SELF-TAPP'G. CONT. P.T. 2x8
TYPE 'A' FSTNR'S. (SEE STRUCT.)
PRE -FIN. ALUMIN. EAVE
TRIM with DRIP EDGE
CONT. P.T. 2x4 FASCIA
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
CONT. 3" PVC SOFFIT VENT
e" EXT. PLYWD. SHEATH'G.
STUCCO FINISH SYS.
AIR/WATER BARRIER
EPS INSUL. FRIEZE with STUCCO FINISH.
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
STUCCO FINISH SYS.
CONT. TAPE MASTIC (OVER SILL SCREED)
2x4 RIGID EPS INSUL. ACCENT
BAND/FRAME with STUCCO FINISH
CONT. PVC SILL SCREED
PRE -FIN. ALUMIN. FLASHING
BTWN. BRICK and STUCCO
1" EXTERIOR THIN BRICK
TOP COURSE - TYP.
CONT. FLUID APPLIED AIRIWATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPEC'S. (SEE ELEV'S.)
4" CONC. SLAB (BROOM FINISH)
SLOPE AWAY FROM BLDG.
VAPOR RETARDER
6x6 W1.4xW1.4 W.W.M.
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH BRICK (2" min.)
FALSE PARAPET CAP FLASH'G
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and
OVER TOP OF PARAPET
LONG -LIFE SELF-TAPP'G FTNR.
with WASHER (TYP. EA. RIB)
SELF-TAPP'G. TYPE'A' FSTNR'S.
with WASHER and TRI-BEAD TAPE
SEALER (TYP.)
CONT. P.T. 2x8 (SEE STRUCT.)
MANUF'S. STD.
ROOF'G. TRANSITION
.USSES at 24" 0
(SEE STRUCT.)
CONT. P.T. 2x8 LEDGER
and JOIST HANGER
(SEE STRUCT.)
CONT. CAULK JT.
ACT CLG.
2 DIAGONAL VINYL LATTICE
(" thk.) EQ. TO PERMALATT
PRODUCTS, INC. (888) 457-4342
EXT. FIRE TREATED PLYWD.
%" DUROCK SHEATHING
RIGID INSUL. BTWN. 7g' CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS.
CONT. FRP J-CHANNEL (CAULKED)
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
CONT. CONC. FTG. (SEE STRUCT.)
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
REFER TO J
ELEVATIONS
MOLDED EPS CORNICE
with STUCCO FINISH. PROVIDE -
CONT. BLOCK'G. AS REQ'D.
CONT. CAULK JT. with BACKER ROD -
PRE-ENG'D. WOOD TRUSSES
at 24" O.C. (SEE STRUCT.)
MANUF'S. STD. HORIZ.
_
EXPANSION JT./ FLASHING SYS.
REFER TO J,
CONT. P.T. (2) 2x8 TOP
ELEVATIONS
PLATE (SEE STRUCT.)
NICHIHA PANEL SYS. -
e" EXT. PLYWD. SHEATH'G. -
SINGLE PLY ROOF SYS.
8" CMU WALL (SEE STRUCT.) -
RIGID POLYISO. INSUL.
AIRIWATER BARRIER
(5" thk. MIN.)
(WRAP & SEAL OPENINGS -
& PENETRATIONS - TYP.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
3 e" CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
' X 6" LAG BOLT INTO (2)
2x8's with e" PLYWD. FILLER
REFER TO PLANS &
ELEV'S FOR DEPTH
WEATHER TIGHT LAMP
(COORD. w/ CANOPY MANUF.)
MANUF'S. STD. HORIZ
EXPANSION JT./ FLASHING SYS
NICHIHA PANEL SYS
AIRANATER BARRIER
(WRAP & SEAL OPENINGS
& PENETRATIONS - TYP.)
e" EXT. PLYWD. SHEATH'G.
3 e" CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
8" CMU WALL (SEE STRUCT.)
CONT. CAULK JT.
CONC. BARRIER CURB
PAVING (SEE CIVIL)
p D D
i
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and OVER TOP OF PARAPET
ROOF'G. MANUF'S. STD. PARAPET WALL
VENT. QTY. TO BE DETERMINED BY THE
UNITS FREE AREA DIVIDED BY REQ'D.
FREE AREA NOTED ON ROOF PLAN.
MANUF'S. STD.
ROOF'G. TRANSITION
8" EXT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
;USSES at 24" O.
(SEE STRUCT.)
CONT. P.T. 2x8 LEDGER and
JOIST HANGER (SEE STRUCT.)
ACT CLG.
SINGLE PLY ROOF SYS.
r
Ls
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
jk ,'AAY BC NECES°ARY:IN ORDER TO:
C.wJIPLy wrrH XL if PLICAN CODES'
%" GWB (MMR)
RIGID INSUL. BTWN. CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS.
CONT. FRP J-CHANNEL (CAULKED)
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
CONT. CONC. FTG. (SEE STRUCT.)
MANUF'S. STD.
ROOF'G. TRANSITION
SINGLE PLY
ROOF SYS.
RIGID POLYISO.
INSUL. (5" thk. MIN.)
PLYWD. ROOF
SHEATH'G.
(SEE STRUCT.)
R. Wulbern
r W Architect PA
w O. AA-0003433 Ile •
N U (904)329.2510 tei
0) U roberk@wulbem.net
�OFF(0
y �R'C C. INU4-- 9p
3 '~
12/4/2017 6:23 PM
�
w
w
L
W
z
z
o�oo
F55
Lu
L
QIt
Y
Y
Ir
>
m
m
w
n
r
F
O
O
O
o
a
d —
n
U
U
N
M
O
x
< o
e
O
Z
r
w �p
z
_
m ¢
❑
U
o
o-
0
w
x
m
z
LL
J
J
U
LL
U
w
a-
U)
tz
x
U
2
of
O
LL
F
H
Q
h
Li
w
x
0
O
Ld
to
O
a_
a.
a
of
w
0
O
z
IY
O
LL
I-
IY
a
z
x
O
w
J
O
z
w
U
0
❑
O
m
o_
w
of
of
O
w
1n
D
w
m
0
O
z
a00}
❑
¢
t
(�
J
z
w
Z
❑
S
z
O
O
,
F—
U
U)
z
w0
I.LI C
u
w
x
�J d
J �
w
` Q
uGoogle Drivew0 Projects Current\1667.07 BK429752 (Kitterman St Lucie Co) (576A1667 07 A-6 1Z Wall Sections.dwg, 12/4/2017 6:23:01 PM
SCALE:
EN (NORTH) ELEVATION
= V-0" at 24%36"
N
SCALE:
IR
at
ELEVATION
A9
❑
w
x
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
MOLDED EPS INSUL. CORNICE
with STUCCO FINISH. PROVIDE
CONT. BLOCK'G. AS RECI'D.
CONT. CAULK JT. with BACKER ROD
s" EXT. PLYWD. SHEATH'G.
NICHIHA PANEL SYS.
CONT. (2) 2X6 BLOCKING at
SIGN MOUNTING POINTS
with LUS26-2 EA. END
MANUF'S. STD. HORIZ.
EXPANSION JT./ FLASHING SYS.
CONT. P.T. (2) 2x8 TOP
PLATE (SEE STRUCT.)
S-2
8" CMU WALL (SEE STRUCT.)
AIR/WATER BARRIER
(WRAP & SEAL OPENINGS
& PENETRATIONS - TYP.)
3 �' CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
}" X 6" LAG BOLT INTO (2)
2x8's with 8" PLYWD. FILLER
REFER TO PLANS &
ELEV'S FOR DEPTH
WEATHER TIGHT LAMP
(COORD. w/ CANOPY MANUF.)
CONT. CAULK JT.
(1) PT2x6 NAILER TOP WITH (2)
3/4" DIA ADHESIVE ANCHORS
AT 24" OC WITH 6 3/4" EMBED.
(TYP. EA. END)
CONCRETE PAVERS OVER 1" SAND
BED AND 8" BASE MATERIAL
(COMP. LBR-100). COORD. w/ CIVIL.
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. MTL. CLEAT FASTEN REFER TO J
ELEVATIONS
at 8" O.C. (TYP. EA. SIDE)
ROOF'G. MANUF'S. STD. PARAPET WALL
VENT. QTY. TO DETERMINED BY THE
AREA
I
UNITS FREE AREAA DIVIDED BY REQ'D.
FREE AREA NOTED ON ROOF PLAN. ��
EXTEND ROOF'G. UP and OVER TOP OF PARAPET ,
SIN N SIN
PRE-ENG'D. WOOD TRUSSES
at 24" O.C. (SEE STRUCT.) —
MANUF'S. STD. N
ROOF'G. TRANSITION 12" 6" 24"
" EXT. PLYWD. ROOF 94"
SHEATH'G. (SEE STRUCT.)
SINGLE PLY ROOF SYS.
REFER TO DECOR PACKAGE
FOR PAINTED FINISH COLOR
FOR TRUSSES, CONDUITS,
ROOF DECK, ETC.
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.) MANUPS. STD. RIGID POLYISO. INSUL.
SINGLE
SYS. �ITION PLYWD.
SEE STRUCT.)
O OF)SHEATH'G.
ROO
2x8 FRAMING
at 24" O.C.
CONT. 2x8 LEDGER and JOIST
HANGER (SEE STRUCT.)
SIMPSON LUS24 HANGER
_ EACH END EACH RAFTER
ATTACHED WITH (4) 10d NAILS
TO NAILER AND RAFTER
CONT. 3" PVC J
SOFFIT VENT /
CONT. CAULK JT. J/
STUCCO FINISH over
AIR/WATER BARRIER and
EXT. PLYWD. SHEATH'G,
1E-EN. WOOD
USSE t 24" O.C.
(SEE UCT.)
t' RIGID INSUL. BTWN. FURR'G STRIPS
r GWB (MMR) ON 8" CFSF FURRING at
16" O.C. TO U/S OF ROOF DECK. RETURN
GWB INTO WINDOW OPEN'G. (TYP.)
S.F. WINDOW HEAD FASTEN
per PRODUCT APPROVAL
INSUL., IMPACT RATED, LOW-E GLAZING
S.F. HORIZ. INTERMEDIATE MULLION
INSUL., IMPACT RATED, LOW-E GLAZING
S.F. WINDOW SILL with SILL
RECEPTOR, SET IN BED of SEALANT
and FASTEN per PRODUCT APPROVAL
CONT. CAULK JT.
C.T. BASE (SEE DECOR).
RETURN C.T. into
WINDOW OPEN'G.
TILE FLOOR (SEE DECOR)
n
9 p T . .• a. 6'•
;
p' a' 0� , ,. GA CI , . . CONC. SLAB with VAPOR RETARDER
A.
CMU STEM WALL (SEE STRUCT.)
3 °
CONT. CONC. FTG. (SEE STRUCT.)
(,—,N)E!NRTY (WEST) ELEVATION
A1 F: 3/4" = 1'-0" at 24"x363/4" = 1'-0" at 24"x36"
CONT. CONC. CURB (SEE STRUCT.)
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR C.T. (SEE ELEV'S.)
CONT. CAULK JT.
)rive\0 Projects Current\1667.07 BK-A29752 (Kitterman St Lucie Cc) (576)\1667 07 A-6 12 Wall Sectiomclwg, 12/4/2017 6.23:21 PM
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
MOLDED EPS CORNICE
with STUCCO FINISH. PROVIDE
CONT. BLOCK'G. AS REQ'D.
CONT. CAULK JT. with BACKER ROD
e" EXT. PLYWD. SHEATH'G.
NICHIHA PANEL SYS.
CONT. (2) 2X6 BLOCKING at
SIGN MOUNTING POINTS
with LUS26-2 EA. END
MANUF'S. STD. HORIZ.
EXPANSION JT./ FLASHING SYS.
CONT. P.T. (2) 2x8 TOP
PLATE (SEE STRUCT.)
S-3
8" CMU WALL (SEE STRUCT.)
AIR/WATER BARRIER
(WRAP & SEAL OPENINGS
& PENETRATIONS - TYP.)
3 1" CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
T' X 6" LAG BOLT INTO (2)
2x8's with 8" PLYWD. FILLER
REFER TO PLANS &
ELEV'S FOR DEPTH
WEATHER TIGHT LAMP
(COORD. w/ CANOPY MANUF.)
CONT. CAULK JT.
" EXT. PLYWD. SHEATH'G.
NICHIHA SOFFIT SYS.
AIRIWATER BARRIER
CONT. CAULK JT.
CONT. CONC. CURB (SEE STRUCT.)
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR C.T. (SEE ELEV S.)
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH ECT-1 G (6" min.)
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
REFER TO
CONT. MTL. CLEAT FASTEN ELEVATIONS
at 8" O.C. (TYP. EA. SIDE)
ROOF'G. MANUF'S. STD. PARAPET WALL
VENT. CITY. TO BE DETERMINED BY THE
UNITS FREE AREA DIVIDED BY REQ'D.
FREE AREA NOTED ON ROOF PLAN.
EXTEND ROOPG. UP and OVER TOP OF PARAPET
PRE-ENG'D. WOOD TRUSSES
LED PARAPET LIGHT'G. BAND -
at 24" O.C. (SEE STRUCT.)
LED UPLIGHTING -
MANUPS. STD.
ROOF'G. TRANSITION
PRE -FIN. ALUMIN. LIGHT BAND -
FLASHING with CONT. CLEAT
" EXT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
REFER TO J,
ELEVATIONS
SINGLE PLY ROOF SYS.
CKAGE
COLOR
DUITS,
=EN
C.
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
MANUF'S. STD.
ROOPG. TRANSITION
SINGLE PLY
ROOF SYS.
RIGID POLYISO.
INSUL. (5" thk. MIN.)
PLYWD. ROOF
SHEATH'G.
n
(SEE STRUCT.)
t P -ENG'D. WN
USSES at 24" O
(SEE STRUCT.)
" RIGID INSUL. BTWN. FURR'G STRIPS
" GWB (MMR) ON 8" CFSF FURRING at
16" O.C. TO U/S OF ROOF DECK, RETURN
GWB INTO WINDOW OPEN'G. (TYP.)
S.F. WINDOW HEAD FASTEN
per PRODUCT APPROVAL
INSUL., IMPACT RATED, LOW-E GLAZING
S.F. HORIZ. INTERMEDIATE MULLION
HORIZ. REVEAL (SEE ELEV'S)
CONT. FLUID APPLIED AIRMATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
INSUL., IMPACT RATED, LOW-E GLAZING
STUCCO FINISH SYS.
CONT. TAPE MASTIC (OVER SILL SCREED)
CONT. PVC SILL SCREED
PRE -FIN. ALUMIN. FLASHING
BTWN. BRICK and STUCCO
S.F. WINDOW SILL with SILL
1" EXTERIOR THIN BRICK
RECEPTOR, SET IN BED of SEALANT
TOP COURSE - TYP.
and FASTEN per PRODUCT APPROVAL
CONT. FLUID APPLIED AIRNVATER
CONT. CAULK JT.
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
C.T. BASE (SEE DECOR).
RETURN C.T. into
V�[
EXTERIOR THIN BRICK VENEER, INSTALL
WINDOW OPEN'G.
PER MANUF'S. SPEC'S. (SEE ELEV'S.)
TILE FLOOR (SEE DECOR)
PARGE COAT EXPOSED CONC. &
iilr.
PAINT TO MATCH BRICK (6" min.)
�j
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
. •
° 3 i..
CONT. CONC. FTG. (SEE STRUCT.)
SENTRY (NORTH) ELEVATION
110
SCALE: 3/4" = 1'-O" at 24"x36"
FALSE PARAPET CAP FLASH'G
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and
OVER TOP OF PARAPET
MANUF'S. STD,
ROOF'G. TRANSITION
USSES at 24" O
(SEE STRUCT.)
j"GWB (MMR) ON 8" CFSF FURRING at
16" O.C. TO U/S OF ROOF DECK.
r RIGID INSUL. BTWN. FURR'G STRIPS
CONT. P.T. 2x8 LEDGER and
JOIST HANGER (SEE STRUCT.)
SINGLE PLY ROOF SYS.
RIGID POLYISO. INSUL.
(5" thk. MIN.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
R. Wulbern
.T Architect PA
5WCOLAA - 0003433 no .
U (904) 329-2510 tel
01 O robertQwulbem.nel e
�EOF F(.0�
y�RSC.WUZB9
33 `
D
12/42017 6:23 PM
�
w
C
�
LWL
In
0(n0
0d
U%
M
Z
Z
J
�
Q
1:CD
w
Y
Y
LL
O
m
LLm
r
-
w
~
o
0
0
i
n
N
ix
of
< o
O
z
LU
z
Y
w
of
i
m Q
it
o
U
O o
lL
goldco
VERTIG
L
. G�:r;f': uuCT1aN
MANAGEMENT .
V
J
N
L0
�
N
Q
Z
¢
N
O
LU
YQ
Rt
M�
Z�
�o
Z
W
J
U_
YO
_
}}
0�0
U)Z
WQ�~w
°L)
rrl
J
�y� �OI�j
W �J
Mz+I
0
Ln
CHAIR RAIL (SEE DECOR) m
F
GWB (MMR) z
> f
RIGID INSUL. BTWN. 8" CFSF
FURRING STRIPS at 16" O.C. z t
FRP PANEL SYS. (SEE DECOR)
1 H SE PLANS AND ALL PROPOSED WORK
CONT. FRP J-CHANNEL (CAULKED) ARE SUBJECT TO ANY CORRECTIONS o Z o
TILE BASE (SEE DECOR) REQUIRED BY FIELD INSPECTORS THAT z O
-AAY-Br NEC€821RY INODERTO_ o
TILE FLOOR (SEE DECOR) COMPLY{IVITHk I,�vpPI.ICA'�. CODES. W U
Z w O
w U) w
°. of
—'
CONC. SLAB with VAPOR RETARDER Z
CMU STEM WALL (SEE STRUCT.) O
• 3 •° a F-N
CONT. CONC. FTG. (SEE STRUCT.) 2� ¢
LLL
�C —
�C Z
DINING (NORTH) ELEVATION z /� _ O
SCALE: 3/4" = 1'-0" ttt 24"x36" /-1
w
x
L ,IIIII i
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
CONT. TAPE MASTIC (OVER SILL SCREED)
14-10 x 2" MASONRY SCREW FSTNR. at 24" O.C.
with TAPE SEALER EA. SIDE of FLEX MEMBRANE
STUCCO FINISH. SYS.
CONT. PVC SILL SCREED
FLEX MEMBRANE
LONG LIFE LAP-TEK FSTNR'S. at 6" O.C.
DO NOT INSTALL THRU PANEL RIB
TRI-BEAD SEALER TOP of CLOSURE
& TOP OF FLEX MEMBRANE
OUTSIDE CLOSURE PANEL with URETHANE
SEALANT at ENDS, PANEL RIBS & LAPPING
CLOSURE TABS (SEAL ALL VOIDS)
J" EXT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
AIR/WATER BARRIER
STANDING SEAM ROOF'G. SYS.
LOW-FOATING CLIP
CONT. 8" EXT. PLYWD NAILER
SELF-TAPP'G. PANCAKE
HEAD FSTNR. at 12" O.C.
NON -SKINNING BUTYL SEALANT
BTWN. PANL RIBS (TYP.)
PRE -FIN. ALUMIN. EAVE
TRIM with DRIP EDGE
CONT. P.T. 2x4 FASCIA
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
CONT. 3" PVC SOFFIT VENT
5'EXT. PLYWD. SHEATH'G.
STUCCO FINISH SYS.
AIR/WATER BARRIER
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
(2) SELF-TAPP'G. CONT. P.T. 2x8
TYPE'A' FSTNR'S. (SEE STRUCT.)
CONT. CAULK IT.
HORIZ. REVEAL (SEE ELEV'S)
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
STUCCO FINISH SYS.
CONT. TAPE MASTIC (OVER SILL SCREED)
CONT. PVC SILL SCREED
PRE -FIN. ALUMIN. FLASHING
BTWN. BRICK and STUCCO
1" EXTERIOR THIN BRICK
TOP COURSE - TYP.
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPECS. (SEE ELEV'S.)
4" CONC. SLAB (BROOM FINISH)
SLOPE AWAY FROM BLDG.
VAPOR RETARDER
6x6 W1.4xW1.4 W.W.M.
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH BRICK (2" min.)
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and
OVER TOP OF PARAPET
LONG -LIFE SELF-TAPP'G FTNR.
with WASHER (TYP. EA. RIB)
SELF-TAPP'G. TYPE'A' FSTNR'S.
with WASHER and TRI-BEAD TAPE
SEALER (TYP.)
CONT. P.T. 2x8 (SEE STRUCT.)
MANUF'S. STD.
ROOF'G. TRANSITION
PRE-ENG'D. WOC
TRUSSES at 24" O
(SEE STRUCT.)
CONT. P.T. 2x8 LEDGER
and JOIST HANGER
(SEE STRUCT.)
/_TNryxell
%" GWB (MMR)
RIGID INSUL. BTWN. J" CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS.
CONT. FRP J-CHANNEL (CAULKED)
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
CONT. CONC. FTG. (SEE STRUCT.)
REFER TO
ELEVATIONS
SINGLE PLY ROOF SYS.
RIGID POLYISO. INSUL.
(5" thk. MIN.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
REFER TO FLOOR PLANS
& STRUCTURAL FOR
SLAB DEPRESSION AT
WALK -IN -BOX (COORD.
with W.I.B. VENDOR)
LED PARAPET LIGHT'G. BAND
LED UPLIGHTING
PRE -FIN. ALUMIN. LIGHT BAND
FLASHING with CONT. CLEAT
CONT. TAPE MASTIC (OVER SILL SCREED)
14-10 x 2" MASONRY SCREW FSTNR. at 24" O.C.
with TAPE SEALER EA. SIDE of FLEX MEMBRANE
STUCCO FINISH. SYS.
CONT. PVC SILL SCREED
FLEX MEMBRANE
LONG LIFE LAP-TEK FSTNR'S. at 6" O.C.
DO NOT INSTALL THRU PANEL RIB
TRI-BEAD SEALER TOP of CLOSURE
& TOP OF FLEX MEMBRANE
OUTSIDE CLOSURE PANEL with URETHANE
SEALANT at ENDS, PANEL RIBS & LAPPING
CLOSURE TABS (SEAL ALL VOIDS)
e' EXT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
AIR/WATER BARRIER
STANDING SEAM ROOF'G. SYS.
LOW-FOATING CLIP
CONT. B" EXT. PLYWD NAILER
SELF-TAPP'G. PANCAKE
HEAD FSTNR. at 12" O.C.
NON -SKINNING BUTYL SEALANT
BTWN. PANL RIBS (TYP.) —�
PRE -FIN. ALUMIN. EAVE
TRIM with DRIP EDGE
CONT. P.T. 2x4 FASCIA
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
CONT. 3" PVC SOFFIT VENT
8" EXT. PLYWD. SHEATH'G.
STUCCO FINISH SYS.
AIR/WATER BARRIER
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
(2) SELF-TAPP'G. CONT. P.T. 2x8
TYPE W FSTNR'S. (SEE STRUCT.)
CONT, CAULK IT.
STUCCO FINISH SYS.
CONT. FLUID APPLIED
AIR/WATER BARRIER
(SEAL OPENINGS &
PENETRATIONS - TYP.)
FLASHING TAPE
OVER DRIP EDGE
PVC DRIP EDGE FLASHING
CONT. CAULK IT.
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
EXTERIOR THIN BRICK VENEER, INSTALL
PER MANUF'S. SPECS. (SEE ELEV'S.)
PARGE COAT EXPOSED CONC. &
PAINT TO MATCH BRICK (6" min.)
FALSE PARAPET CAP FLASH'G
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. NAILER (DRILL
OUT FOR A.B. BELOW)
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and
OVER TOP OF PARAPET
LONG -LIFE SELF-TAPP'G FTNR.
with WASHER (TYP. EA. RIB)
SELF-TAPP'G. TYPE W FSTNR'S.
with WASHER and TRI-BEAD TAPE
SEALER (TYP.)
CONT. P.T. 2x8 (SEE STRUCT.)
MANUF'S. STD. /
ROOF'G. TRANSITION
SINGLE PLY
ROOF SYS.
11E WOOD
USSE t 24" O.C.
(SEE UCT.)
REFER TO
ELEVATIONS
RIGID POLYISO. INSUL.
(5" thk. MIN.)
PLYWD. ROOF SHEATH'G.
(SEE STRUCT.)
4" RIGID INSUL. BTWN. FURR'G STRIPS
GWB (MMR) ON g' CFSF FURRING at
16" O.C. TO U/S OF ROOF DECK. RETURN
GWB INTO WINDOW OPEN'G. (TYP.)
S.F. WINDOW HEAD FASTEN
per PRODUCT APPROVAL
INSUL., IMPACT RATED, LOW-E GLAZING
S.F. HORIZ. INTERMEDIATE MULLION
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
_odAY BG NECES°aRY IN.ORD�R T0:
�0°11PLYd111T1�!L;�P�.ICA°��iCODES`
INSUL., IMPACT RATED, LOW-E GLAZING
S.F. WINDOW SILL with SILL
RECEPTOR, SET IN BED of SEALANT
and FASTEN per PRODUCT APPROVAL
CONT. CAULK IT,
C.T. BASE (SEE DECOR).
RETURN C.T. into
WINDOW OPEN G.
r— TILE FLOOR (SEE DECOR)
aa <
CONC. SLAB with VAPOR RETARDER
CMU STEM WALL (SEE STRUCT.)
CONT. CONC. FTG. (SEE STRUCT.)
Q
0 ir
N
R. Wulbern
t Architect PA
O O AA .0003433 Ilc "
N U (W) 329-2510 tel e
0) U robert(twulbernmet e
EL E
U 0
a�i m
c m
c
m
c
� o
c a�Oi
mw
N �
f0 >
a
� N
w
c E
O d
o�
N 'N
N +a
'NO C
a @
N N
'O 01
0) N
(0 N
c
d �
c
c .N m
1
m D
U 0)
O 0'
U N
o
� U
W c
O
cc M
°1
2- E
N U
Fa- o
0
z
z
0
LI
x
f-
F �FI.O,Qi
Pt�c.�
0`�RT C. t'YU�eF9
a
.ARG�
D
12/4/2017 6:24 PM
S
W
�
LL
r
w
�
w
CJ
L
w
w
Z
z
o
O
W
^
O
_
N
N
Y
z
z
LL
N
LU
cW7
CW'J
0
Of
>LL
m
m
LLJ
0
0
0
0
a
0
o
d
d _
Y
N
M
�
o
z--^^
U W
z
a
Y
w —
of
w
2
c �
Q
o
Cr
0 goldco
VERI
L
0...�
ci
co
N
L0
0
N
z
Q
N
.:
W
M
0
Ha
Zo
Yo
�-
O
Z
Wu
J
pe:00::)5
W
I—
O
O
U
O
�tl
00
J
m�zCD
Lo
,ogle Drive\0 Projects Current\1667.07 BK-A29752 (Kitterman St Lucie Co) (576)\1667 07 A-6 12 Wall Sections.dwg, 12/4/2017 6:23:46 PM
., KITCHEN (EAST) ELEVATION
SCALE: 3/4" = V-0" at 24%36"
WINDOWS (WEST) ELEVATION
SCALE: 3/4" = 1'-0" at 24"x36"
A-11
R. Wulbern
r Architect PA
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
REFER TO
ELEVATIONS Y
MOLDED EPS CORNICE
with STUCCO FINISH. PROVIDE -
CONT. BLOCK'G. AS REQ'D.
CONT. CAULK JT. with BACKER ROD -
PRE-ENG'D. WOOD TRUSSES
at 24" O.C. (SEE STRUCT.)
MANUF'S. STD. HORIZ. _
EXPANSION JT./ FLASHING SYS.
CONT. P.T. (2) 2x8 TOP
PLATE (SEE STRUCT.)
NICHIHA PANEL SYS. -
8" EXT. PLYWD. SHEATH'G. -
8" CMU WALL (SEE STRUCT.) -
AIR/WATER BARRIER
(WRAP & SEAL OPENINGS -
& PENETRATIONS - TYP.)
3 8" CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
CONT. FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
CFSF BOX BEAM HEADER
3 8" CFSF at 16" O.C.
CONT. 3" PVC SOFFIT VENT
STUCCO FINISH over
AIR/WATER BARRIER and 8"
EXT. PLYWD. SHEATH'G.
CONT. CAULK JT.
NICHIHA PANEL SYS. (BEYOND)
NICHIHA CORNER TRIM
(TR-1 G) - TYP. at ALL
OUTSIDE CORNERS
STAINLESS STL. SILL
NICHIHA PANEL SYS.
CONT, FLUID APPLIED AIR/WATER
BARRIER (SEAL OPENINGS &
PENETRATIONS - TYP.)
8" CMU WALL (SEE STRUCT.)
CONT. CAULK JT.
CONIC. BARRIER CURB
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
EXTEND ROOF'G. UP and OVER TOP OF PARAPET
ROOF'G. MANUF'S. STD. PARAPET WALL
VENT. QTY. TO BE DETERMINED BY THE
UNITS FREE AREA DIVIDED BY REQ'D.
FREE AREA NOTED ON ROOF PLAN.
MANUF'S. STD.
ROOF'G. TRANSITION
8" EAT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
SINGLE PLY ROOF SYS.
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
PRE-ENG'D. WOO
TRUSSES at 24" 01
(SEE STRUCT.)
CONT. P.T. 2x8 LEDGER
and JOIST HANGER
(SEE STRUCT.)
PAF FASTEN CFSF
TRACK TO FACE OF CMU
ACT CLG.
t' RIGID INSUL. BTWN. FURR'G STRIPS
FRP SYS. ON 8" GWB (MMR) with B" CFSF
FURRING at 16" O.C. TO ABV. CEILING.
RETURN GWB INTO WINDOW OPEN-G. (TYP.)
S.F. WINDOW HEAD FASTEN
per PRODUCT APPROVAL
INSUL., IMPACT RATED, LOW-E GLAZING
CAULK PERIMETER BOTH SIDES
STAINLESS STL. SILL SET
IN BED OF SEALANT
V GWB (MMR) 3'-0" AFF }
SILL HEIGHT
RIGID INSUL. BTWN. e" CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS.
CONT. FRP J-CHANNEL (CAULKED)
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
44-
\ • -�—�
°
• * °
CONC. SLAB with VAPOR RETARDER
• • CMU STEM WALL (SEE STRUCT.)
4 L4
s°
CONT. CONC. FTG. (SEE STRUCT.)
15 D/T WINDOW I
SCALE: 3/4" = 1'-0" at 24
ELEVATION
MANUF'S. STD.
ROOF'G. TRANSITION
SINGLE PLY
ROOF SYS.
RIGID POLYISO.
INSUL. (5" thk. MIN.)
PLYWD. ROOF
SHEATH'G.
(SEE STRUCT.)
SNAP -ON PRE -FIN. MTL.
PARAPET CAP FLASHING,
SLOPE to ROOF
REFER TO
ELEVATIONS Y
MOLDED EPS CORNICE
with STUCCO FINISH. PROVIDE -
CONT. BLOCK'G. AS REQ'D.
CONT. CAULK JT. with BACKER ROD -
PRE-ENG'D. WOOD TRUSSES
at 24" O.C. (SEE STRUCT.)
MANUF'S. STD. HORIZ. _
EXPANSION JT./ FLASHING SYS.
CONT. P.T. (2) 2x8 TOP
PLATE (SEE STRUCT.)
NICHIHA PANEL SYS. -
8" EXT. PLYWD. SHEATH'G. -
8" CMU WALL (SEE STRUCT.) -
AIR/WATER BARRIER
(WRAP & SEAL OPENINGS -
& PENETRATIONS - TYP.)
3 8" CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
MANUF'S. STD. HORIZ.
EXPANSION JT./ FLASHING SYS.
NICHIHA PANEL SYS.
AIR/WATER BARRIER
(WRAP & SEAL OPENINGS
& PENETRATIONS - TYP.)
8" EXT. PLYWD. SHEATH'G.
3 8" CFSF at 24" O.C. CLIP
TO CMU (SEE STRUCT.)
8" CMU WALL (SEE STRUCT.)
CONT. CAULK JT.
CONC. BARRIER CURB
WRAP FLEXIBLE FLASHING
OVER TOP of PARAPET
CONT. MTL. CLEAT FASTEN
at 8" O.C. (TYP. EA. SIDE)
�— EXTEND ROOF'G. UP and OVER TOP OF PARAPET
ROOF'G. MANUF'S. STD. PARAPET WALL
VENT. QTY. TO BE DETERMINED BY THE
UNITS FREE AREA DIVIDED BY REQ'D.
FREE AREA NOTED ON ROOF PLAN.
MANUF'S. STD.
ROOF'G. TRANSITION
8" EAT. PLYWD. ROOF
SHEATH'G. (SEE STRUCT.)
SINGLE PLY ROOF SYS.
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
PRE-ENG'D. WOOD
TRUSSES at 24" O.C.
(SEE STRUCT.)
N
CONT. P.T. 2x8 LEDGER and
JOIST HANGER (SEE STRUCT.)
ACT CLG.
%" GWB (MMR)
RIGID INSUL. BTWN. "CFSF
FURRING STRIPS at 16" O.C.
FRP PANEL SYS.
CONT. FRP J-CHANNEL (CAULKED)
TILE BASE (SEE DECOR)
TILE FLOOR (SEE DECOR)
CONC. SLAB with VAPOR RETARDER
• • CMU STEM WALL (SEE STRUCT.)
°
-4
CONT. CONC. FTG. (SEE STRUCT.)
/T (ET) ELEVATION
:14)!ALE: 3/4" = 1'-0" at 24"x36"
MANUF'S. STD.
ROOF'G. TRANSITION
SINGLE PLY
/- ROOF SYS.
RIGID POLYISO.
INSUL. (5" thk. MIN.)
PLYWD. ROOF
SHEATH'G.
(SEE STRUCT.)
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT.
odAY.BC NECESQIRY IN.ORDER TOY
C.091PLY WITH A!L APPLICAft4 CODES:
CL AA - 0003433 Ile
yU (904)329-2510 tal e
0) U robertt@mlbern.net e
CL C
U 2
-p U
N 0)
c d
m
ai
`o
c d
o)
y .L
f0 >
m �
wE
(D
o c
c m
A N
N .L.
m 0))
�o m
a: m
lQ N
Na
c
d �
c y
O1 c
N p)
2 d)
m o
N U
a c
co com
a)
_ E
iE
N U
F— 90
OF FL�p
•!
P
WU4 9
* _ z•.
ti
1214/20176:24 PMII��
65
Z
s
W
Z
a
o
a
O_
N
N
Y
8
z
z
N
0
[L
Elf
C
cD
m
LL
m
W
~
a
o
0
0
c0
0
r
o
N
r
d
d �
n
N
�
O
U
U
ao
O
Z
W
U
Z
3
]C
L)
w
W
-)
in
U
o
a
goldco
VERTICAL
. CGr,51 �llC fILYM
M4f4AGLMLv
r .
00=ft%
V
J
04
L0
N
a
z
aN
LU�
W
'qr
O�
Ya
rp
Z
W
�
J
L-
O
O
C)
�
j
LLJ�
jW
O
:D
�,rl
oo
J
M �O1��1jj
0
00
z
(0
U)
w
1n
Z)
w
m
O
z
z
z 0 z
w Z
0
z O
O
F—
O W
LU
w
= J
w ` Qz
F-
A
Google Drive\0 Projects Current\1667.07 BK-A29752 (Kitterman St Lucie Cc) (576)\1667 07 A-6 12 Wall Sections.dwg, 12/4/2017 6:24:16 PM
SEE PLANS F®R
LOCATION of
ACCESSORIES
SOLID SURFACE BK.
-_ SPLASH (COORD. Og
COLOR/MANUF. W/
� DECOR VENDOR)
1�
X
N CD Oe
Th in 00 i'7
CN
TYP. DETAIL FOR
HAND DRYER, SOAP DISP.
WASTE RECEPTACLE
K SCALE: I IZ' = P-0" at 24"x30'
CLEAR ALUMINUM 2' # 2" * 2" � � 2
FRAME iv '` _ _ — 2' 2,—C„ Ir
_
2 0 N
R 2„ 2„ h —
il
— CLEAR rr CLEAR ALUMINUM 1
FRAME io
tI. tI ALUMIN. v
FRAME 0 I I T
.t I
N N
I - SELF -CLOSING
DRIVE -THROUGH WINDOW (with FLORIDA
C14 PRODUCT APPROVAL No.171): -- �� 4
QUIKSERV MODEL #SC-4030-IP
rn N * DEPENDENT ON DRIVE -THROUGH R R
N
(48"W x 36"H) o WINDOW SELECTED. VERIFY LATEST
'r1 -OR- DIMENSIONAL INFORMATION WITH 7h
READY ACCESS MODEL 600 SERIES (47 " THE MANUFACTURER.
1/2" W x 43 1/2" H)
NDOWD
.E: 1/4" = 1'-0"
r
WINDOW Q
SCALE: 1/4" = 1'-0"
WINDOWD
SCALE: 1/4" = 1'-0"
COORD DIMENSIONS WITH
STRUCTURAL and. FIELD VERIFY
1.
219 -9 f 5„ , --3 -O
2" " 2" f 5 , 2 2'
ALUMINUM
r
I
N
WINDOW 0
SCALE: 1/4" = 1'-0"
WINDOW 0
— r-0 „
GALE: 1/4" = S 1
3'-6"
�- N �3'-2
WINDOW <�>
SCALE: 1/4" = 1'-0"
OR FRAME
O
PEN 2'-6"x6'-8" MATERIAL ALUMINUM
IAL: OLID CORE HPL FINISH: REFER TO DECOR PACKAGE
: REF TO DECOR PACKAGE
RDWA
DOOR TO RECEIVE:
HINGES: 2 EACH GER: 1250 4 1/2 x 4 1/2 x 652
(SPRING HI ES)
LOCKSET: i EACH SCHLA , AL40S SAT x 626
WALL STOP: 1 EACH HAGER 2
SILENCERS: 2 EACH HAGER 307W xBR 0 N O T
DOOR ,3
SCALE: 1/4" = 1'-
2 N
DOORFRAME
SCALE: 1/4"
ALUMINUM
HEAD O
JAMB(
SILL
O
DOOR
FRAME
DOOR FRAME
OPENING: 3'-0"x7'-0"xi 3/40x AD x AF
MATERIAL: ALUMINUM
OPENING: 3'-0"x7'-0"x1 3/4% AD x AF MATERIAL: ALUMINUM
MATERIAL: ALUMINUM / GLASS fFINISH:
CLEAR
MATERIAL: ALUMINUM / GLASS FINISH: CLEAR
FINISH: CLEAR
FINISH: CLEAR
HARDWARE
REMARKS
HARDWARE
ENTRANCE DOOR HARDWARE SHALL
DUMMY CYLINDERS
ENTRANCE DOOR HARDWARE SHALL CONSIST OF OFFSET
CONSIST OF OFFSET PIVOTS, ADAMS
SHALL BE PROVIDED ON THE EXTERIOR OF
ALL
PIVOTS, ADAMS RITE MS-1852S DEAD BOLT LOCK WITH
RITE MS-1852S DEAD BOLT LOCK WITH
DOORS EXCEPT AT MAIN ENTRY.
ADAMS RITE 4089 EXIT INDICATOR INCLD'G. HEADER
ADAMS RITE 4089 EXIT INDICATOR
SIGNAGE, NORTON 1605 SURFACE CLOSER WITH BACK
INCLD'G. HEADER SIGNAGE, NORTON
CHECK, B-KING CORP. DOOR PUSH/PULLS. PROVIDE
1605 SURFACE CLOSER WITH BACK
WEATHERSEALS, BOTTOM RAIL DOOR SWEEP and STANDARD
CHECK, B-KING CORP. DOOR
PUSH/PULLS. PROVIDE 2'
r 2 2" 2'
2
FL/ADA THRESHOLD.
W'EATHERSEALS, BOTTOM RAIL DOOR
�-
5"
-8'-5
SWEEP and STANDARD FL/ADA
THRESHOLD.
_
2„ �12,
O 112, 3'-0A
T= TEMPERED N
N
T= TEMPERED N000
"
N
HEAD
-
N HEAD
0
o REFER TO
SHEET A-9
REFER TO
SHEET A-9
o
JAMB
o ` o JAMB
REFER TO
SHEET A-9
REFER TO
SHEET A-9
0
N ,SILL
O
0 _
SILL
G
-
T .—
N T
k- 3'-0" ✓ MINIMUM
--3'-0"O MINIMUM
DOOR O RAILFOM
DOOR FRAME
DOOR O RAILBOTDOOR FRAME
SCALE: 1/4" = 1'-0° DIMENSION
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0" DIMENSION SCALE: 1/4" = 1'-0"
DOOR
FRAME
DOOR FRAME
OPENING: 3'-0"x6'-8"x1 3/4"WD x AF
MATERIAL: ALLUMINUM
OPENING: 4'-0"x7'-O"x1 3/4% MD x MF MATERIAL: HOLLOW METAL
MATERIAL: SOLID CORE HPL
FINISH: REFER TO DECOR PACKAGE
MATERIAL: HOLLOW METAL FINISH: PAINT -REFER TO SHEET A-2 & A-2.1
FINISH: REFER TO DECOR PACKAGE
FINISH: PAINT - REFER TO SHEET A-2 & A-2.1
HARDWARE
REMARKS
HARDWARE
EACH DOOR TO RECEIVE:
SIGN PACKAGE: 1 "KITCHEN" AND
DOOR TO RECEIVE:
HINGES: 3 EACH HAGER: BB1279 4 1/2 x 4 1/2 x 652 CORRESPONDING SIGNAGE IN GRADE TWO BRAILLE PER ADA
HINGES: 4 EACH HAGER: BB1168 4 1/2" x 4 1/2" x USP x NRP
LOCKSET: 1 EACH SCHLAGE, AL53PD SAT x 626
REQUIREMENTS. SIGNS FURNISHED BY DECOR SUPPLIER.
EXIT DEVICE: 1 EACH VON DUPRIN 22EO x 689
CLOSER: 1 EACH LCN 4111 EDA
SIGNS INSTALLED BY GENERAL CONTRACTOR
PER ADA
CLOSER: 1 EACH LCN 4116 EDA
FLOOR STOP: 1 EACH HAGER 241F x US26D
REQUIREMENTS,
VIEWER: 1 EACH ROCKWOOD 622 x 626
KICKPLATES: 2 EACH HAGER 193S 10"x2" LOW 628
AS AN OPTION IN LIEU OF SOLID CORE DOORS AND HOLLOW
KICKPLATES: 1 EACH HAGER 193S 32"x2" LDW 628 (INSTALL W/FLAT HEAD PHILLIPS HEAD SCREWS)
(INSTALL W/FLAT HEAD PHILLIPS HEAD
SCREWS) HOLLOW METAL FRAMES, PROVIDE MARLITE HPL DOORS WITH
THRESHOLD: 1 EACH NATIONAL GUARD 325 x 48' x AL
SILENCERS: 3 EACH HAGER 307D RBR
ALUMINUM FRAMES.
DOOR SWEEP: 1 EACH NATIONAL GUARD 20ONA x 48"
DOOR VIEWER: 1 EACH ROCKWOOD 622 x 626
WEATHERSTRIP: 1 SET NATIONAL GUARD 160SA 1048", 2084"
2 \. 2
2„ 2„
---4'-0"--
3'-0"
IN
12"0 GLASS
` N HEAD
OD
/ � HEAD
OA
o 00 JAMB
O
°/
/ VIEWER
o N a JAMB
to
io \
T°
io io
SILL
O
\ SILL
O
DOOR ®
DOORFRAME_
DOOR O DOORFRAME
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1 -0
DOOR
FRAME
DOOR FRAME
OPENING: 3'-0"x6'-8"
MATERIAL: ALLUMINUM
OPENING: 3'-0"x6'-8"x1 3/4% WD x MF MATERIAL: ALLUMINUM
MATERIAL: SOLID CORE HPL/GLASS
FINISH: REFER TO DECOR PACKAGE
MATERIAL: SOUD CORE HPL FINISH: REFER TO DECOR PACKAGE
FINISH: REFER TO DECOR PACKAGE
FINISH: REFER TO DECOR PACKAGE
HARDWARE
REMARKS
HARDWARE REMARKS
DOOR TO RECEIVE:
AS AN OPTION IN LIEU OF SOLID CORE DOORS AND HOLLOW
EACH DOOR TO RECEIVE: SIGN PACKAGE: 1 "LADIES", 1 "GENTLEMEN" AND
HINGES: 3 EACH HAGER: BB1279 4 1/2 x 4 1/2 x 652 HOLLOW METAL FRAMES, PROVIDE MARLITE HPL DOORS 'MTH
HINGES: 3 EACH HAGER: BB1279 4 1/2 x 4 1/2 x 652 CORRESPONDING SIGNAGE IN GRADE TWO BRAILLE PER ADA
LOCKSET: 1 EACH SCHLAGE, AL53PD SAT x 626
ALUMINUM FRAMES.
CLOSER: 1 EACH LCN 4111 EDA REQUIREMENTS. SIGNS FURNISHED BY DECOR
SUPPLIER,
WALL STOP: 1 EACH HAGER 236W x 630
LOCKSET: 1 EACH FALCON: D271 X 626 SIGNS INSTALLED BY GENERAL CONTRACTOR PER ADA
KICKPLATES: 2 EACH HAGER 193S 10"x2" LDW 628
PUSH PLATE: 1 EACH HAGER 30S 416 628 REQUIREMENTS.
(INSTALL W/FLAT HEAD PHILLIPS HEAD SCREWS)
PULL PLATE: 1 EACH HAGER H33E 416 628 AS AN OPTION IN LIEU OF SOLID CORE DOORS
AND HOLLOW
SILENCERS: 3 EACH HAGER 307D RBR
WALL STOP: 1 EACH HAGER 236W x 630 (DOOR #7) HOLLOW METAL FRAMES, PROVIDE MARLITE HPL
DOORS WITH
KICKPLATES: 2 EACH HAGER 193S 10"x2" LDW 628 ALUMINUM FRAMES.
(INSTALL W/FLAT HEAD PHILLIPS HEAD SCREWS)
SILENCERS: 3 EACH HAGER 307D RBR
NOTE:
2"-\ 2'
UNDERCUT DOOR i" FOR AIR FLOW WHEN HVAC 2' /2"
s� 3'-0" r
N
NOT PROVIDED (REF. SHEET M-1). Yx--3'-0" ,
�
-
HEAD
Op
- HEAD
Op
24"x34"
VISION PANEL
I
o Do JAMB
I1
O
00 o 00 JAMB
1 T I
<
O
io
io 'to
(0 0
SILL
O
SILL
OF
�—V-O"
r 3, 4..
DOOR ®
DOORFRAME
DOOR 6 7 DOOR FRAME
SCALE: 1/4" = 1'-0"
SCALE: 1 /4" = 1'-0"
SCALE: 1/4" = 1'-0" SCALE; 1/4" = 1'-0"
OR
FRAME
DOOR FRAME
OPENI 3'-0"x6'-8"
MATERIAL: ALLUMINUM
OPENING: 3'-0"x7'-O"x1 3/4% MD x MF MATERIAL: HOLLOW METAL
MATERIAL. SOLID CORE HPL
FINISH: REFER TO DECOR PACKAGE
MATERIAL: HOLLOW METAL FINISH: PAINT - REFER TO SHEET A-2 &
A-2.1
FINISH: RE TO DECOR PACKAGE
FINISH: PAINT - REFER TO SHEET A-2 & A-2.1
HARDWA
HARDWARE
DOOR TO RECEIVE:
DOOR TO RECEIVE:
HINGES: 2 EACH GER: 1250 4 1/2 x 4 1/2
x 652
HINGES: 4 EACH HAGER: BB1168 4 1/2" x 4 1/2" x USP x NRP
(SPRING HI ES)
EXIT DEVICE: 1 EACH VON DUPRIN 22EO x 689
LOCKSET: 1 EACH SCHL AL40S SAT x 626
CLOSER: 1 EACH LCN 4111 EDA
WALL STOP: 1 EACH HAGER 2 W x 630
N O T
KICKPLATES: 1 EACH HAGER 193S 10"x2" LDW 628 (INSTALL W/FLAT HEAD PHILLIPS HEAD SCREWS)
SILENCERS: 2 EACH HAGER 307 BR
THRESHOLD: 1 EACH NATIONAL GUARD 325 x 36" x AL
DOOR SWEEP: 1 EACH NATIONAL GUARD 20ONA x 36"
WEATHERSTRIP: 1 SET NATIONAL GUARD 160SA 1036", 2®84" 'm COPY
FIE
[
2"2
2° 2"
--3'-0"
HEAD
Op
12"x12" INSUL'D., HEAD
O
IMPACT RATED GALZING
�f
S D �, JAMB
E
O
o N o JAMB
I I I
B
O
I
it
� I
io io
^ O
\
12' .A.F.F.
LL
F
O
� SILL
OC
f- 3'-0"--� 3'-4••
DOOR 1, 12
DOOR FRAME
DOOR 10 DOOR FRAME
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0" SCALE: 1/4"
J
X
UM SLOPE 1:2
R�
'-ICF X
-1d
ACCESSIBLE THRESHOLD REW
SCALE: 1'-0" = 1'-0"
STUCCO PRODUCT TO BE APPLIED
IN STRICT ACCORDANCE WITH
MANUFACTURES REQUIREMENTS,
DOOR HEADER
(REF. 1 /A-6)
BACKER ROD AND SEALANT
TS
5/8" GYP. BOARD
(2) 2x4 HEADERS
METAL DOOR FRAME
-- -- " �-METAL DOOR FRAME
WOOD BLOCKING WITH LAG SCREWS
--)HEADER DETAIL �D HEADER DETAIL
SCALE: 3" = 1'-0" SCALE: 3" = V-0"
(2) 2x6 WOOD STUDS
STUCCO PRODUCT TO BE APPLIED
IN STRICT ACCORDANCE WITH
MANUFACTURES REQUIREMENTS.
BACKER ROD AND SEALANT
METAL DOOR FRAME
(#)JAMB=DETAL�.
SCAL
ALUM. THRESHOLD
FINISHED FLOOR a �
THRESHOLD DETAL
SCALE: 3" = 1'-0"
THESE PLANS AI4D ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
I AAY Br NECES!ARY-IN."QRDEi TO
CO"APLYWITH;Pis PLICA !AiCODES.°
ALUM. THRESH01
BY MANUFACTUF
FINISHED FLOOR
G THRESHOLD DETAL
SCALE: 3" 1'-0"
P
Imo=
(2)2x4 WOOD STUDS
O METAL FOOR FRAME
E JAMB DETAIL
SCALE: 3" = 1'-0"
IJ
� J
a�<
fV
N /-FINISHED FLOOR
THRESHOLD DETAIL
SCALE: 3" = 1'-O"
SEALANT
FRP SILL
ALUMINUM STOREFRONT
SEALANT
1/8" SHIM SPACE
5/8" GYP. BOARD
NOTE: SILL ® 3'-9" A.F.F.
WINDOW HEIGHT = 2'-6'
H OFFICE SILL DETAIL
SCALE: 3" = 1'-0"
Specified Products and Approved Equals
Hinges - Provide features, functions, size and finish as shown in hardware sets.
HAGER
1361279
3131165
253
MCKINNEY
TA2714
T4A3786
BOMMEP
5155000
113135004
Locks - Provide features, functions and finish as shown in hardware sets.
FALCON - DEADLOCK
0871
NO SUBSTITUTIONS
SCHLAGE
AL53PD
AL405
YALE
ALJ5307LN
AU5302LN
FALCON
B511D
5301D
Exit Device - Provide features, functions and finish as shown in hardware sets.
VON DUPRIN
22 EO
YALE
2 1 OO EO
5ARGENT
3828 EO
Closers - Provide features, functions and finish as shown In hardware sets.
LCN
14G I
41 15 H-GUSH
YALE
3301
4425T/4421T
DORMA
8616
8916 D5T/895G DST
Push/Pull, KP, Stops, Etc. - Provide features, functins, size and finish as shown in
hardware sets.
HAGER
KICKPLT 1935
PULL PLT H33E
PU5H PLT 305
PL STOP 241 F
WALL 5TOP 236W
VIEWER 1 756
ROCKWOOD
K1050 133E
BF106 X 70C
70C
441CU
409
622
TRIMCO
K0050
101 7-3x2 i PROJ.
100 1 -3
1 2 1 1
1 270WV
976U
Weatherstripping, Thresholds, Etc. - provide features, functions, size and finish as
shown in hardware sets.
NATIONAL GUARD
THRE511OLD 325A
SWEEP 20ONA
WEATHERSTRIP I G05A
PEMKO
229A
315CN
303A5
ZERO
Ir75A
39A
99A
R. Wulbern
w oi Architect PA
O CL O AA.0003433 Ile"
N V (204)329-2510 tel "
N 'V _ rober[d�wulbernmet a
mac
0
N N
c m
'= a
a�
m
�7 C
�o
m ri
{a
.� d
'v .0
d
�w
�c
m
air
N
Ar
c
ID
c °
wd
. C
rn
T'jq
i4 o
'G �
O 2
a
15
4) U
S�
c
m
= Y
E c
E
N m
Q
FL- v
A,��OF FtO,pi
C. wOZg�, y
12/4/2017 6:29 PM
o1��ga
N
Id
CDN
40
W
Q
lL
�X�o'0
m
IL
r`
1.
W
47
01
0
o
o
a
2
N
<f o
a
O
z "o
z
U
UJ
LU
X
i
`� a
m
O
U
OO 0
CP9.0I.Ov' vYweeenmws=�
VERTICAL
.CQN9TRilCY1fAN MANAGENEW .
0
J
U)
N
Ln
4m
W
N
Q
Z
Q
N
.`.
O�
Of
LU
Y
rn
NT
co
Q
(7
o
Z a
W
ILL
Y O
o
U)
51
W
OE#4)
H
=
I--
0
W
CO
�
M O
rrl
Z
aQ
(0
J
U)
J
Z)
0 U)
W
W
IY 0
A-13
Projects Current\1667.07 BK-A29752 (Kitterman_St Lucie Cc) (576)\1667-07 A-13 Door Schedule & Detaiis.dwq, 12/4/2017 6:28:19 PM
DIRECTORY OF MANUFACTURERS AND SUPPLIERS
Thic Ikt ng building materials and products. In many cases, approved Burger King materials and products may be purchased directly from these sources at a national accounts price. For a complete listing of approve
see
E: 6-2-17
SIGNS, EQUIPMENT, PLAYGROUNDS AND D COR
,N 4 - MASONRY
DIVISION 9 -FINISHES
DIVISION 15 -MECHANICAL
EVERPURE, INC
L.S.I,
INTEGRATED CONTROL CORP.
CHARTER HOUSE INC.
4LL BRICK CO.
NLL B
EVOLUTION BRICK
RINNAI
(INSTANT WATER HEATERS)
(WATER FILTERS)
(MENU BOARDS)
(KITCHEN MINDER)
(DECOR)
(FACE BRICK)
RINNAI NATIONAL ACCOUNT PRICING THROUGH HAINES,
1040 MUIRFIELD DRIVE
10000 ALLIANCE ROAD
748 PARK AVENUE
4660136 AVENUE w
iOREFAIR DRIVE, NW
126 OLD HIGHWAY 60 EAST
FOR FINISH MATERIALS, AND CONTACTS, REFER TO FINISH SCHEDULES
FOUND IN THE "COMMON DOCUMENTS" SECTION
JONES, & CADBURY. CONTACTTHE BURGER KING CSR AT
HANOVER PARK, IL. 60133
CINCINNATI, OH 45242
HUNTINGTON, NY 11743
HOLLAND, MI.49424 0
OR 317-774-8880 m
)N-SALEM, NC 27105
HARDINSBURG, KY 40143
OF THE WWW.DESIGNWITHBK.COM
WEBSITE.
HJC 800-459-7099 FOR RINNAI TANKLESS WATER HEATER
JEANNINE GAINE: 630-240-1298
BRITTANY KOESTER: 513-372-33910R
JOHN PATT1: 631-673-5100 EXT 325
BARB ZILM: 800-314-7659
barbara.zilm@charter-house.com o
>A BEANS: [800) 334-86$9
GABS POWERS: (502) 558-4612
PRICING (MISCELLANEOUS)
jeannine.gaine@pentair.com
513-315-3725
www.gotochi.com
E@PINEHALLBRICK.COM
SUMMITVILLE TILE CO
RHEEM
(WATER HEATERS)
SELECTO SCIENTIFIC, INC
FEDERAL HEATH SIGN CO
AWNINGS, CANOPIES AND SIGNS)
DUKE MANUFACTURING
(PRODUCT HOLDING UNITS)
SEATING CONCEPTS a
(DECOR) d
DDOX BRICK CO.
TRICK)
(REPLACEMENT STRATA TILE)
101 BELL ROAD
39 OTLAKEFIEIRDCOURT
12704 DUPONT CIRCLE
.63102 Y
125 ELL STREET
RADSHAW ROAD
330-223-1511
MONTGOMERY, AL. 36117
SUWANEE, GA. 30024
TAMPA, FL. 33626
ST. LOUTS MO.63102
ST. L UIS M
KDAL
ROCKDALE, IL. 6D436 0
NENTO, CA 95827
800-621-5622 OR
EHUD LEVY: 578-475-1445
FIONA PAUL: 800-284-3284 EXT. 19
SUE SCIUTO: 800-735-3853 EXT 1260
ZACH DEPYSSLER: 815-483-2244
9-6320
CONTACT HAINES, PONES, & CADBURY (MISCELLANEOUS)
edlevy@selectoinc.com
fpaul@federalheath.com
ssciuto@dukemfg.com
zdepyssler@seating-concepts.com o,
v
(U
DIVISION 10 -SPECIALTIES
PRODUCTS
KOALA KARE PRODUCTS
A.O. SMITH
(WATER HEATERS)
N.C.A.
NATIONAL HVAC PRODUCTS, LLC.
CUMMINGS SIGNS, INC
(AWNINGS, CANOPIES AND SIGNS)
FRYMASTER CORPORATION
(FRYERS)
FCC COMMERCIAL FURNITURE o
(DECOR] 0
8452 OLD HWY. 99 NORTH °c
)N 5 - METALS
1N STEEL
BOBRICK
(RESTROOM ACCESSORIES, TOILET PARTITIONS* AND
(BABY CHANGING STATIONS)
600 E. JOHN CARPENTER FREEWAY, SUITE 200
(AIR CONDITIONING - FULL SERVICE)
15 CENTURY BLVD, SUITE 200
NASHVILLE, TN. 37214
8700 LINE AVE
SHREVEPORT, LA 71106
ROSEBURG, OR. 97470 m
;TURAL STEEL)
HARDWARE)
CONTACT HAINES, JONES, & CADBURY (MISCELLANEOUS)
IRVING, TX. 75062
4585 140 AVENUE NORTH
ANN BAKER:
LAURA Ds@fryma$erfi
DN IL
7-1554
FMP DISTRIBUTORS
800-447-1953
CLEARWATER, FL. 33762
877-530-0078
ann.baker@ ulmm n8ss5i38s.com
g g
eqo derom711
0
ORESTON 800--3202'7328 EXT2844-5284
ROB GRUBER:800-257-7737 OR 609-267-3700
972-719-5900
c
preston.ohara@fccfurn.com @
*GREEN PRODUCT
CARRIER CORPORATION
LOREN COOK CO
ENTERA SIGNS
GAYLORD INDUSTRIES
CASABLANCA DESIGN GROUP
AMERICAN STANDARD
COLUMBIA VORTEX
(AIR CONDITIONING)
(EXHAUST FANS)
(AWNINGS, CANOPIES AND SIGNS)
(HOODS)
(DECOR)
(RESTROOM ACCESSORIES)
(HAND DRYERS)
2015 E. DALE
1200 ENTERA DRIVE
10900 SOUTH AVERY STREET
811 PICKENS INDUSTRIAL DRIVE
C
1 CENTENNIAL AVENUE
825 GARLAND STREET
6304 CARRIER PARKWAY
SPRINGFIELD, MO 65803-4637
PANAMA CITY, FL. 32401
TUALATIN, OR. 97062
MARIETTA, GA 30026
PISCATAWAY, NJ.08854
866-337-7286 EXT. 1136
SYRACUSE, NY. 13221
KEN DICKSON: 813-966-9200
850-797-1779
JOHN ANDERSON: 971-223-1238
JOHN HARRISON: 770-423-9575 T
CONTACT HAINES, PONES, &CADBURY (MISCELLANEOUS)
DEBORAH ROY-TONES: 315-432-7441
john.anderson@gaylordusa.com
John.Harrison@cdg.com u
800-690-1086
ken.dickson@tampabay.rr.com
ZURN INDUSTRIES
(PLUMBING FIXTURES)
UNI-STRUCTURES, INC
(CANOPIES & AWNINGS)
TRANS
(AIR CONDITIONING UNITS, RTU's/SPLIT SYSTEMS
CONTROLS)
AMEREX CORPORATION
(FIRE PROTECTION SYSTEMS)
7595 GADSDEN HIGHWAY
SIGN RESOURCE
(AWNINGS, CANOPIES AND SIGNS)
6135 DISTRICT BLVD.
LANCER
(DRINK DISPENSERS)
6fi55 LANCER BLVD
FACILITY CONCEPTS, INC (FCI) 15
(DECOR) a
7676 ZIONSVILLE ROAD
)N 7- THERMAL MOISTURE PROTECTION
LAST ROOFING
G.A.F.
200FING)
(FLAT ROOF)
1801 PITTSBURG AVENUE
8540 COBB CENTER DR.
2884 CORPORATE WAY
TRUSSVILLE, AL 35173-0081
MAYWOOD, CA. 90270
SAN ANTONIO, TX. 78219
INDIANAPOLIS, IN 46268
ORLEY DRIVE
1361 ALPS ROAD
ERIE, PA. 16502
KENNESAW, GA. 30152
MIRAMAR, FL. 33025
LISA JONES: 205-655-5760
RAMON ORTIZ: 323-326-6463
MIKE KRAWETZKE: 817-692-5044
KEN WEAVER: 800-915-8890 EXT. 103 s
AW, MI 48601
WAYNE, NJ. 07470
CUSTOMER SERVICE: 855-663-9876
BRET HANKS: 678-974-1766
AL MARTINEZ: 954-499-2289 OR 800-440-9554
Ijones@amerex-fire.com
rortiz@signresource.com
michael.krawetzke@lancercorp.com
kweaver@fcius.com w
BEUTHIN: 800-432-9331
(201) 528-3000
www.zurn.com
b.hanks@unistructures.com
bkhvac@trane.com
www.amerex-fire.com
CALVIN DURR: 800-915-8890 EXT 303 y
s
NTHA PICKELMAN 989-758-1048 OR 989-930-9$26
800-7663411
cdurr@fcius.com F-
SAN JAMAR
WORLD DRYER, CO
AMERICAN STANDARD
(TOILET, URINAL, FAUCETS)
ALLEN INDUSTRIES, INC
(AWNINGS, CAN AND SIGNS)
NIECO CORPORATION
(BROILERS)
INTERIOR SYSTEMS, INC
(DECOR)
)GE ROOFING
TAMKO ROOFING PRODUCTS
tL ROOF)
(FLAT ROOFING)
(RESTROOM ACCESSORIES & SUPPLIES)
(HAND DRYERS)
1135149TH STREET NORTH
7950 CAMERON DRIVE
241 NORTH BROADWAY, SUITE 600
HALL
HALL
P.O. BOX 1404
555 KOOPMAN LANE
5700 MCDERMOTT DR.
1 CENTENNIAL AVE.
CLEARWATER, FL 33762
WINDSOR, CA 95492
MILWAUKEE, WI 53202
TX.
POPLIN, MO. 64802
JOPLIN, MO.
ELKHORN, WI.
ELKHORN, WI
BERKELEY, IL. 60163
BERK
PISCATAWAY, NJ. 08855
PISCATAWAY,
THERESATRIMMER; 800-677-3075 EXT, 3422
CHRISTINA NEAT: 707-284-7100
JIM ZIELINSKI: 414-232.3502
NTONI7 ,
TTS
JOHNPOTTS
theresa.trimmer@atlenindustries.com
sales@nieco.com
JZielinski@isiamerica.com
www23-613 ar.com
32 EXT 133 OR (815) 347-0811
JASON FREDRICKSON: 414-224-0972
OR CONTACT HAINES, JONES, & CADBURY
john.potts@worlddryeccom
jfredrickson@islamerica.com
(MISCELLANEOUS)
LEKTRON, INC
PITCO
COMMERCIAL INTERIOR MANUFACTURERS, INC
-ONE METAL PRODUCTS
BASF CORPORATION
UNIVERSAL MANUFACTURING
(PARAPET LIGHT BANDS)
(FRYERS)
(LIMITED D ITEMS)
\L ROOF)
(POLYURETHANE ROOFING SYSTEMS)
(RESTROOM ACCESSORIES)
E. 4fith PLACE
l0 FERRY STREET
THE
HOLLY STREET
ZEST 96TH STREET
1703 CROSS POINT AVE
5366 CRESTVIEW DR.
TULSA, OK. 74145
TULS
CONCORD, NH. 03301
JASPER, GA. 30143
JASPER,
NAPOLIS, IN 46260
HOUSTON, TX 77054
MEMPHIS, TN. 38134
KEVINOM
BONNIE BOLSTER: 603-230-5529
- 4761
(E KOREEDA: 615-345-9991
MOSES M CLARK, JR: 315-263-4665
901-458-5881
800-634-4059 OR 918-622-4978 EXT 309
800-6 4-4059
bbolster@pitco.com
STEVE BOUDREAU
STEV
dayusuke@firestonebp.com
800-821-1414
krubottom@lektroninc.com
steve@cimgbiz.com
AUSTIN HOLAN
austin@cimgbiz.com
FRANKE
TAYLOR ULTIMATE SERVICES, INC
NAUTICAL FURNISHINGS, LLC
ON 8-DOORS AND WINDOWS
DIVISION 16 - ELECTRICAL
(KITCHEN EQUIPMENT, SMALLWARES, HOODS)
800 AVIATION PARKWAY
(SHAKE MACHINE, FROZEN BEVERAGE MACHINE)
1780 NORTH COMMERCE PKWY
(LIMITED DECOR ITEMS)
60 NW 60TH STREET
LSI INDUSTRIES INC.
(INTERIOR AND EXTERIOR LIGHTING, SURVEYS AND
SECURITY LIGHTING SYSTEMS
(EXTERIOR SITE AND BUILDING LIGHTING, SURVEYS AND
iERV
MARLITE
E-THRU WINDOWS)
-THRU WINDOWS)
[DOOR, ALUMINUM FRAMES)
(DO
PHOTOMETRICS)
PHOTOMETRICS)
SMYRNA, TN. 37086
WESTON, FL. 33326
FT. LAUDERDALE, FL 33309
. ORE PARK DRIVE
HARGER STREET
10000 ALLIANCE ROAD
2100 GOLF ROAD, SUITE 460
CUSTOMER SERVICE: 800-877-5178
TINA SMART: 954-217-9100
MICHAEL HOGLUND: 954-771-1100
TON, TX.
TON, T7
DOVER, NH 44622
DOVE , NH 4
CINCINNATI, OH. 45242
ROLLING MEADOWS, IL. 60008
fs-bkparts.us@franke.com
tina@taylorus.com
mhoglund@nauticalfurnishings.com
8 830
BRITTANY KOESTER: 513-372-3391 OR
ERIC HILLESLAND: 630-636-8493
KURTHORS21
513-315-3725
ehillesiand@security lighting.com
aquikserv.com
khorstmann@marlite.com
3M SOUND PRODUCTS
CREE /HERMITAGE LIGHTING NATIONAL ACCOUNTS
QUALSERV SOLUTION
PLAY SYSTEMS (DIY. OF SUPERIOR TNT. INDUSTRIES, INC)
ARMSTRONG STRATEGIC ACCOUNTS
Y ACCESS
UNIVERSAL MANUFACTURING CO
(DRIVE-THRU SOUND SYSTEM & SATELITE ANTENNA)
(INTERIOR AND EXTERIOR LIGHTING, SURVEYS AND
(KITCHEN EQUIPMENT, SMALLWARES)
(PLAYGROUND MANUFACTURER)
(CEILING TILE)
'THRU WINDOWS &AIR CURTAINS)
E TH
E
(HOLLOW METAL FRAMES &DOORS, WOOD DOORS,
3M CENTER
PHOTOMETRICS)
7400 SOUTH 28th STREET
1050 COLUMBIA DR.
2500 COLUMBIA AVENUE
UR DRIVE WEST
ART U DRIVE
HARDWARE (HINGES, LOCKS, ETC)
ARE (HINGES,
HARDWAREES,RD.
BLDG. 223-2N-20
3640 TROUSDALE DRIVE
FORT SMITH, AR. 72908
CARROLLTON, GA 30717
LANCASTER, PA. 17604
O, IL. 6 185
ST. PAUL, MN. 55144-1000
NASHVILLE, TN. 37204
BECKY DUBOSE: 479-221-1467
JUAN CUELLAR: 770-832-6660 EXT. 1517
LOUIS JOHN: 407-697-6768
' 800-621-5045 EXT 113
CGOL RICKcom
MEMPHIS, TN. 38134
MEMPHIS, TN
JOE CIAMPI: 704-771-2449
STEVEFRIED AN:8 7-830 1444
bdubose@qualservsolutions.com
jcuellar@siibrands.com
800-442-4212
ar
0R 800-821-1414
jjciampi@mmm.com
W
Ijjohn@armstrongceilings.com
OR ARMSTRONG STRATEGIC ACCOUNTS
800-264-3383
(800)442-4212
SECURITY PRODUCTS, INC
HM ELECTRONICS, INC (HME)
H & K INTERNATIONAL (KITCHEN EQUIPMENT,
SPI INDUSTRIES
USG INTERIORS
3M COMMERCIAL CORE DIVISION
(REAR DOOR ALARM)
(DRIVE-THRU SOUND SYSTEM)
SMALLWARES, HOODS)
(PLAYGROUND MANUFACTURER)
(CEILING TILE)
(WINDOW FILM)
30950 COREAL DRIVE, SUITE B
14110 STOWE DRIVE
2200 SKYLINE DR
BOX 100, R.R. #2, JOINT ST.
CHRIS BENJAMIN: 312-436-5458
3M CENTER
R
COARSEGOLD, CA. 93614
POWAY, CA. 92064
DALLAS, TX 75223
SHALLOW LAKE, ON, NOH 2KO CANADA
cbenjamin@usg.com
ST. PAUL,
ST. PAUL, MN
BOB BARR OR EMILY BEACH: 800-452-5276
PAUL KOOSER: 800-848-4468
HEATHER VALVERDE: 214-818-3521
CYNTHIA MASTERS: 519-935-2174 OR 519-378-4356
OR 800-328-0033
orders@security productsinc.com
paulk@hme.com
heather.valverde@hki.com
cmasters@spiplastics.com
www,spiplastics.com
N.C.A.
NATIONAL HVAC PRODUCTS, U.C.
SUNCOAST ENVIRONMENTAL CONTROLS, INC.
(ELECTRICAL SWITCH GEAR)
INTERNATIONAL COLD STORAGE (ICS)
(WALK-IN COOLERS / FREEZERS, DRY STORAGE
SOFT PLAY, LLC
(PLAYGROUND MANUFACTURER, SAFETY SURFACING, NOW
MITYLITE
(2020 LIGHT CHAIRS AND BARSTOOLS)
(MASTER CONTROL SYSTEM)
8655 115th AVENUE NORTH
COMPARTMENTS)
CONTAINED PLAY EQUIPMENT)
1301 WEST NORTH
4585 140 AVENUE NORTH
LARGO, FL. 34643
215 EAST 13th STREET
13620 EAST REESE BLVD. SUITE 300
OREM, UT
CLEARWATER, FL. 33762
877-544-6679
ANDOVER, KS. 67002
HUNTERSVILLE, NC. 28078
KAREN EDWARDS: 561-213-2810
877-530-0078
LISA MOORE: 800-835-0001 EXT 4177
JIM SWINTEK: 704-948-3448
lisa.moore@icsco.com
jim.swintek@softplay.com
HILL PHOENIX POWER SYSTEMS DIVISION
TRANE CO.
3M FOOD SERVICE BUSINESS
MOSS RETAIL AND ENVIRONMENTS
TWENTY FOUR 7 GLOBAL SOLUTIONS, INC.
(FACTORY INTEGRATED SWITCH GEAR)
(ENERGY MANAGEMENT PANEL)
(DRIVETHRU COMMUNCATION PRODUCTS, MAINTENANCE
(GRAPHICS)
(2020 LIGHT AND GARDEN GRILL CHAIRS AND BARSTOOLS)
8166 INDUSTRIAL BLVD
2884 CORPORATE WAY
PRODUCTS, MATTING AND TRACTION PRODUCTS,
2643 WEST CHICAGO AVE
898 NORTH SEPULVEDA BLVD, SUITE 465
COVINGTON, GA. 30014
MIRAMAR, FL. 33025
MONITOR STRIPS, TAPES AND DISPENSERS, LAMINATING
CHICAGO, IL 60622
EL SEGUNDO, CA 90245
PAUL BROWN: 678-699-0129
AL MARTINEZ: 954-499-2289
SYSTEMS)
DJ SCANDIFF: 773-435-7600 EXT 617
ROB LORTS: 773-435-7600 EXT 655
BARRY WOON: 323-319-2722
THESE PLANS AND
paul.brown@hil{phoenix,com
ammartinez@trane.com
3M CENTER
BLDG, 223-2N-20
rlorts@mossinc.com
ALL PROPOSED WORK
. ARE SUBJECT TO ANY CORRECTIONS
ST. PAUL, MN. 55144-1000
REQUIRED BY FIELD INSPECTORS THAT
JOE CIAMPI: 704-771-2449
-AAXBC, NEC MARYIN ORDER TO.
jjciampi@mmm.com
COMPLY WITH A+,C01�1.ICJarl CODES:`
HM ELECTRONICS, INC (HME)
(DRIVE-THRU WIRELESS INTERCOMS, DRIVE-THRU SPEED
VGS, INC
(GRAPHICS)
WAUSAU TILE, INC
(EXTERIOR DECOR)
OF SERVICE TIMERS, DIGITAL SURVEILLANCE SYSTEMS)
1696 MABRY MILL DRIVE, SW
P.O. BOX 1520
14110 STOWE DRIVE
NORTH CANTON, OH 44709
WAUSAU, WI 54402-1520
POWAY, CA. 92064
GREG MOROZ: 201-528-9680
STEVE THUT: 800-388-9728 EXT 320
PAUL KOOSER: 800-848-4468
ORDER EMAIL: BURGERKING@VGS-INC.COM
sthut@wausautile.com
paulk@hme.com
Q
MISCELLANEOUS
HAINES, JONES, AND CADBURY
(PACKAGE PRICING ON MULTIPLE ITEMS BING, TI�
RESTROOM ACCESSORIES, ETC)
310 SW 24TH STREET
BENTONVILLE, AR 72712
BARRY BRYANT:479-899-3555
barry.bryant@hjcinc.com
I
R. Wulbern
Architect PA
AA - 0003433 lic
(904)329-2510 tel •
robeftAwulbern.net •
<EOF,FLO!P
Q M
q OARS C. wuze y
D .A�G�
12/4/2017 6:27 PM
z
z
0
W
a
0
cn
o
QLu
Y
Y
lL
O
OfE
w
�
7
7
m
LL
m
w
r
H
Q
rn
o
0
v
0
o
O
O
N
a
d
gr
U
U
N
O
of
O
< o
p {�
z ,0
W
U
z
z
U
e W
w—
7
x
=
°` a
�
0
U
O 0
d
O
z
C
w
C
C
a
l
tt
Of
C
c
z
a
goldco��" a mom.
VERTICAL
O
d
J
v/
LO
N
Q
z
<N
..
�0)
LU
M
O
u
�Q
Y
0
'O
Z
P
W
y
SS
J
W
2
n
O
O
�
�
W
O
0
�Of�j
rrl
Qo
J
0
w
(n
D
w
m
r
z
z
0
J
¢
z
z
w
0
z
0
U
LD
z
0
w
M
w
x
0
z
z
0
w
x
t-
LLI U)
CK ry
LLI
U -C
aMLL CL
D
-7 U)
A-14
GENERALNOTES
100. DESIGN CRITERIA
100.1 DESIGN BUILDING CODE
A. FLORIDA BUILDING CODE, 2014
100.2 GRAVITY LOADS:
A. ROOF LIVE LOADS:
1. FLAT ROOF 20 PSF
100.3 LATERAL LOADS:
A. WIND LOADS (IN ACCORDANCE WITH DESIGN BUILDING CODE PER
GENERAL NOTE 100.1):
1. ULTIMATE DESIGN WIND SPEED (3 SECOND GUST), Vult= 161 MPH
2. NOMINAL DESIGN WIND SPEED (3 SECOND GUST), Vasd = 125 MPH
3. RISK CATEGORY = II
4. EXPOSURE CATEGORY = C
5. ENCLOSURE CLASSIFICATION = ENCLOSED
6. INTERNAL PRESSURE COEFFICIENT (GCpi) = +/- 0.18
7. COMPONENTS AND CLADDING PRESSURES: SEE "COMPONENTS
AND CLADDING WIND LOADS" TABLE, AND "COMPONENTS AND
CLADDING WIND PRESSURE DIAGRAM"
110. GENERAL
110.1 THESE DRAWINGS HAVE BEEN PRODUCED ENTIRELY ON ATLANTIC
ENGINEERING SERVICES CADD SYSTEM. ANY OTHER LETTERING, LINES, OR
SYMBOLS, OTHER THAN PROFESSIONAL STAMPS AND SIGNATURES, HAVE
BEEN MADE WITHOUT THE AUTHORIZATION OF ATLANTIC ENGINEERING
SERVICES AND ARE INVALID.
110.2 THE STRUCTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL
STRUCTURAL FEATURES, UNLESS NOTED OTHERWISE. THE
ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL
DIMENSIONS.
110.3 DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. ONLY DIMENSIONS
INDICATED ON DRAWINGS MAY BE USED TO ESTABLISH THE LOCATION AND
EXTENT OF STRUCTURAL WORK. IF A REQUIRED DIMENSION IS NOT
FURNISHED ON DRAWINGS, THE CONTRACTOR SHALL SUBMIT A REQUEST
FOR INFORMATION TO OBTAIN THE DIMENSION.
110.4 THE METHOD AND FREQUENCY OF ATTACHING MECHANICAL EQUIPMENT
UNITS, ETC., TO THE STRUCTURAL ELEMENTS SHALL BE SUBJECT TO THE
ENGINEER'S REVIEW AND APPROVAL.
110.5 UNLESS OTHERWISE INDICATED, STRUCTURAL COMPONENTS SUPPORTING
MECHANICAL EQUIPMENT HAVE NOT BEEN DESIGNED FOR THE VIBRATIONAL
EFFECTS OF THE EQUIPMENT. THE CONTRACTOR SHALL PROVIDE
VIBRATION ISOLATORS FOR ANY MECHANICAL EQUIPMENT MOUNTED TO
THE STRUCTURE IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S
RECOMMENDATIONS.
110.6 THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION SEQUENCING
AND ALL TEMPORARY SHORING AND STABILIZATION THAT IS REQUIRED TO
PERFORM THEIR WORK. WHERE REQUIRED, THE CONTRACTOR SHALL
RETAIN THE SERVICES OF A REGISTERED PROFESSIONAL ENGINEER
LICENSED TO PRACTICE IN THE STATE OF FLORIDA FOR THE DESIGN OF
TEMPORARY SHORING AND BRACING, THE CONTRACTOR IS RESPONSIBLE
FOR PERFORMING THEIR WORK IN A SAFE AND SATISFACTORY MANNER.
110.7 ALL STRUCTURAL WORK SHALL BE INSPECTED IN ACCORDANCE WITH THE
BUILDING CODE AND ALL LOCAL ORDINANCES. THE OWNER SHALL ENGAGE
AN EXPERIENCED, QUALIFIED INSPECTION AGENCY, SUBJECT TO THE
REVIEW OF THE ARCHITECT, TO PERFORM ALL INSPECTION WORK, AS
REQUIRED.
120. SHOP DRAWINGS
120.1 THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW BY
ATLANTIC ENGINEERING SERVICES AND THE PROJECT ARCHITECT, SHOP
DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL COMPONENTS
LIMITED TO
INCLUDING, BUT NOT , THE FOLLOWING:
A. FABRICATED STRUCTURAL STEEL
B. REINFORCING STEEL FOR CONCRETE AND MASONRY
C. CONCRETE AND/OR MASONRY POST -INSTALLED ANCHORS
D. PRECAST CONCRETE LINTELS (IF USED)
E. PREFABRICATED WOOD TRUSSES INCLUDING COLD FORMED METAL
FABRICATIONS UTILIZED IN TRUSS -TO -FRAME CONNECTIONS.
120.2 SHOP DRAWINGS TO BE SUBMITTED SHALL PROVIDE COMPLETE
INFORMATION FOR THE PRODUCTS OR COMPONENTS TO BE SUPPLIED.
SUBMITTAL INFORMATION SHALL INCLUDE, BUT NOT BE LIMITED TO: MEMBER
SIZES AND DIMENSIONS; GRADES OF MATERIAL FURNISHED; MATERIAL
PREPARATION REQUIRED; MATERIAL FINISH AND MATERIAL COATINGS TO BE
FURNISHED; INFORMATION REGARDING CUTS, COPES, AND HOLES
REQUIRED FOR OTHER TRADES; END CONNECTIONS; CAMBER AND OTHER
DEVIATION FROM LINE; SPECIAL ERECTION AND/OR INSTALLATION
PROCEDURES, INCLUDING REQUIREMENTS FOR TEMPORARY STABILIZATION,
120.3 ALL SHOP DRAWING RESUBMITTALS AND RECORD COPY SUBMITTALS SHALL
HAVE ALL REVISIONS SUBSEQUENT TO THE PREVIOUS SUBMISSION
CLOUDED OR OTHERWISE IDENTIFIED ON THE RESUBMITTED SHEETS.
RESUBMITTALS AND RECORD COPY SUBMITTALS WITHOUT IDENTIFICATION
OF REVISIONS WILL BE REJECTED WITHOUT REVIEW.
120.4 THE CONTRACTOR SHALL NOT DIRECTLY INCORPORATE THE STRUCTURAL
DRAWINGS, OR PORTIONS THEREOF, INTO SHOP DRAWINGS OR ERECTION
DRAWINGS TO BE SUBMITTED FOR THIS PROJECT WITHOUT FIRST
OBTAINING THE EXPRESS WRITTEN PERMISSION OF ATLANTIC ENGINEERING
SERVICES. SUBMITTED SHOP DRAWINGS WHICH CONTAIN COPIES OR
REPRODUCTIONS OF ANY PORTION OF THE STRUCTURAL DRAWINGS
WITHOUT THE EXPRESS WRITTEN PERMISSION OF ATLANTIC ENGINEERING
SERVICES WILL BE RETURNED REJECTED. PERMISSION FORA SPECIFIC
CONTRACTOR OR SUB -CONTRACTOR TO USE PORTIONS OF THE
STRUCTURAL DRAWINGS IN THEIR PREPARATION OF SHOP DRAWINGS
REQUIRES THAT CONTRACTOR OR SUB -CONTRACTOR TO ENTER INTO A
WRITTEN AGREEMENT WITH ATLANTIC ENGINEERING SERVICES AND TO PAY
A SERVICE FEE. SUCH AGREEMENT IS NON-TRANSFERRABLE AND IS
OF THIS
EXTENDED ONLY TO THAT CONTRACTOR FOR THE DURATION
PROJECT.
120.5 THE CONTRACTOR SHALL SUBMIT ELECTRONIC COPIES OF SHOP DRAWINGS
IN LIEU OF PRINTED COPIES. ELECTRONIC COPIES SHALL BE SUBMITTED TO
ATLANTIC ENGINEERING SERVICES IN PDF FILE FORMAT, WITH ONE (1)
ELECTRONIC FILE PER PACKAGE SUBMISSION. ATLANTIC ENGINEERING
SERVICES WILL REVIEW, ANNOTATE, AND RETURN ONE (1) ELECTRONIC
PACKAGE TO THE ARCHITECT TO REVIEW AND DISTRIBUTE TO THE
CONTRACTOR.
120.6 THE REVIEW OF SHOP DRAWINGS AND OTHER SUBMITTALS FOR THIS
PROJECT IS FOR CONFORMANCE WITH THE DESIGN CONCEPT AND FOR
GENERAL COMPLIANCE WITH THE INFORMATION CONTAINED IN THE
CONTRACT DOCUMENTS. COMMENTS REGARDING THESE SUBMITTALS DO
NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE CONTRACT
DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING HIS
WORK IN A SAFE AND SATISFACTORY MANNER.
200. FOUNDATIONS - GENERAL
200.1 FOUNDATIONS HAVE BEEN DESIGNED AND SHALL BE CONSTRUCTED IN
ACCORDANCE WITH CRITERIA ESTABLISHED BY UNIVERSAL ENGINEERING
SCIENCES, INC. IN THEIR GEOTECHNICAL REPORT DATED APRIL 25, 2017
(UNIVERSAL PROJECT NO. 0330.1700048.0000).
200.2 THE CONTRACTOR SHALL OBSERVE WATER CONDITIONS AT THE SITE AND
TAKE THE NECESSARY PRECAUTIONS TO ENSURE THAT THE FOUNDATION
EXCAVATIONS REMAIN DRY DURING CONSTRUCTION. PROVIDE FOR
DEWATERING AS NECESSARY.
200.3 THE CONTRACTOR SHALL USE EXTREME CAUTION DURING EXCAVATION.
SUCH EXCAVATION SHALL BE PERFORMED IN SUCH A MANNER AS TO
MAINTAIN THE STRUCTURAL INTEGRITY OF ALL EXISTING STRUCTURES TO
REMAIN. PROVIDE TEMPORARY SHORING AS REQUIRED.
200.4 CONCRETE SLABS ON GRADE HAVE BEEN DESIGNED TO BEAR ON
COMPACTED SUBGRADE SOILS OR PROPERLY COMPACTED FILL AS PER THE
REPORT REFERENCED IN NOTE 200.1.
210. SHALLOW FOUNDATIONS
210.1 FOUNDATIONS HAVE BEEN DESIGNED AND SHALL BE CONSTRUCTED IN
ACCORDANCE WITH CRITERIA ESTABLISHED IN THE GEOTECHNICAL REPORT
REFERENCED IN NOTE 200.1.
210.2 SPREAD FOOTINGS HAVE BEEN DESIGNED TO BEAR ON UNDISTURBED SOILS
OR PROPERLY COMPACTED FILL HAVING AN ALLOWABLE BEARING CAPACITY
OF 2,500 PSF, AS PER THE GEOTECHNICAL REPORT REFERENCED IN NOTE
200.1.
210.3 ELEVATIONS SHOWN ON THE DRAWINGS AT WHICH FOUNDATIONS ARE TO
BEAR ARE APPROXIMATE. MATERIAL ON WHICH FOUNDATIONS ARE TO BEAR
SHALL HAVE AT LEAST THE ABOVE NOTED CAPACITY, ALL EXTERIOR
FOOTINGS SHALL BEAR A MINIMUM OF 18" BELOW FINISHED GRADE.
210.4 STEP FOOTINGS BELOW ALL SANITARY AND WATER LINES. PROVIDE STEPS
IN THE FOUNDATIONS IN ACCORDANCE WITH THE TYPICAL DETAILS.
COORDINATE THE EXACT LOCATION AND ELEVATION OF THE PLUMBING
LINES WITH THE MECHANICAL AND PLUMBING DRAWINGS AND
CONTRACTORS. PROVIDE SLEEVES IN THE FOUNDATION WALLS AS
REQUIRED FOR PIPE PENETRATIONS.
210.5 THE CONTRACTOR SHALL RETAIN THE SERVICES OF A PROFESSIONAL
GEOTECHNICAL ENGINEER, SUBJECT TO THE APPROVAL OF THE ARCHITECT,
TO INSPECT THE FOUNDATIONS, BEARING LEVELS, ETC., AND VERIFY THAT
THE MATERIAL ON WHICH FOUNDATIONS BEAR HAS AT LEAST THE ABOVE
NOTED CAPACITY.
300. REINFORCED CONCRETE
300.1 ALL REINFORCED CONCRETE WORK SHALL BE IN CONFORMANCE WITH THE
"BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI 318,
LATEST EDITION) AND SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI
301, LATEST EDITION) OF THE AMERICAN CONCRETE INSTITUTE.
300.2 MINIMUM DESIGN COMPRESSION STRENGTH (F'c) REQUIRED AT 28 DAYS:
A. FOUNDATIONS 3000 PSI
B. SLABS ON GRADE 4000 PSI
C. COLUMNS AND BEAMS 4000 PSI
300.3 MAXIMUM WATER TO CEMENTITIOUS MATERIALS RATIO:
A. FOUNDATIONS 0.60
B. SLABS ON GRADE 0.45
C. COLUMNS AND BEAMS 0.45
300.4 ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (MINIMUM 144 PCF)
WITH ALL CEMENT CONFORMING TO ASTM C150, TYPE I, II OR 1/II. MAXIMUM
AGGREGATE SIZE SHALL BE 1-1/2" FOR FOOTINGS AND 3/4" FOR WALLS AND
SLABS, CONFORMING TO ASTM C33.
300.5 REINFORCEMENT
A. DEFORMED BARS AST
M A615
GRADE 60
B. WELDED WIRE FABRIC ASTM A1064
300.6 MINIMUM COVER FOR CAST -IN -PLACE CONCRETE REINF., UNLESS
OTHERWISE SHOWN ON DRAWINGS, SHALL BE AS FOLLOWS:
A. FOUNDATIONS 3"
B. COLUMNS (OVER VERT. REINF.) 2"
C. BEAMS (OVER MAIN REINF.)
2"
D. SLABS CAST AGAINST EARTH 2"
300.7 SPLICES IN REINFORCEMENT, WHERE PERMITTED, SHALL BE AS FOLLOWS:
A. WELDED WIRE MESH 8"
B. ALL OTHERS CLASS "B" TENSION,
CASE 1" MINIMUM,
UNLESS OTHERWISE
NOTED
300.8 CLASS "B", CASE "1" TENSION SPLICES IN INCHES, SHALL BE AS FOLLOWS:
3000 PSI 4000 PSI
SIZE TOP BARS ALL OTHERS TOP BARS ALL OTHERS
#3 (#10) 28 22 24 19
#4 (#13) 37 29 32 25
#5 (#16) 47 36 40 31
#6 (#19) 56 43 48 37
#7 (#22) 81 63 70 54
300.9 SPLICES IN TOP REINFORCEMENT SHALL BE LOCATED AT MIDSPAN AND
SPLICES IN BOTTOM REINFORCEMENT SHALL BE LOCATED OVER SUPPORTS,
UNLESS NOTED OTHERWISE.
300.10 BARS IN BEAMS SHALL TERMINATE IN A CLASS "B" TENSION SPLICE OR HOOK
AT DISCONTINUOUS END.
300.11 PARALLEL REINFORCEMENT PLACED IN TWO OR MORE LAYERS SHALL HAVE
A CLEAR DISTANCE BETWEEN LAYERS OF 1". UPPER LAYER BARS SHALL BE
PLACED DIRECTLY ABOVE BARS IN THE BOTTOM LAYER.
300.12 ALL REINFORCING SHALL BE HELD SECURELY IN POSITION WITH STANDARD
ACCESSORIES DURING PLACEMENT OF CONCRETE. REINFORCING
SUPPORTS FOR ALL EXPOSED CONCRETE SHALL BE GALVANIZED WITH
PLASTIC COATED FEET. ALL WELDED WIRE MESH SHALL BE CHAIRED IN
ACCORDANCE WITH THE DESIGN BUILDING CODE.
300.13 ALL TIES SHALL HAVE 135 DEGREE HOOKS.
300.14 PROVIDE 1/2" PREMOULDED EXPANSION MATERIAL WHERE SLAB ON GRADE
IS POURED AROUND COLUMNS AND AGAINST WALLS UNLESS OTHERWISE
SHOWN ON DRAWINGS.
300.15 CONTRACTION JOINTS FOR SLABS ON GRADE SHALL BE SPACED NO MORE
THAN 12'-0" ON CENTER. PANELS FORMED BY JOINTS OR SLAB EDGES SHALL
BE AS SQUARE AS POSSIBLE WITH A LENGTH -TO -WIDTH RATIO NOT TO
EXCEED 1.5.
300.16 CONTRACTOR SHALL VERIFY DIMENSIONS AND LOCATIONS OF ALL SLOTS,
PIPE SLEEVES, ETC., AS REQUIRED FOR MECHANICAL TRADES BEFORE
CONCRETE IS PLACED.
300,17 PIPES OR CONDUITS PLACED IN SLABS SHALL NOT HAVE AN OUTSIDE
DIAMETER LARGER THAN 113 THE SLAB THICKNESS AND SHALL NOT BE
SPACED CLOSER THAN 3 DIAMETERS ON CENTERS. ALUMINUM CONDUITS
SHALL NOT BE PLACED IN CONCRETE. NO CONDUITS SHALL BE PLACED IN
SLAB WITHIN 12" OF COLUMN FACE OR FACE OF BEARING WALL. NO
CONDUITS MAY BE PLACED IN EXTERIOR SLABS.
300.18 PRIOR TO CONCRETE PLACEMENT, THE CONTRACTOR SHALL SUBMIT A
CONCRETE MIX DESIGN PREPARED IN ACCORDANCE WITH ACI-318 CHAPTER
5 TO THE STRUCTURAL ENGINEER FOR REVIEW.
350. CONCRETE/MASONRY ANCHORS
350.1 ALL ADHESIVE STUD ANCHORS FOR ANCHORING TO CONCRETE SHALL BE
"HILTI HIT-HY 200 ADHESIVE CONCRETE ANCHORS" AS MANUFACTURED BY
HILTI FASTENING SYSTEMS, INC. (OR APPROVED EQUIVALENT).
350.2 THE "HAS ANCHOR ROD" SHALL CONFORM TO ASTM A36 STEEL, THE "HAS
SUPER ANCHOR ROD" SHALL CONFORM TO ASTM A193 STEEL, AND THE NUT
SHALL CONFORM TO ASTM A563, GRADE A.
350.3 THE SPACING AND MINIMUM EMBEDMENT OF POST -INSTALLED ANCHORS
SHALL BE AS INDICATED ON DRAWINGS. THE INSTALLATION OF THE
ANCHORS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDED PROCEDURES.
420. MASONRY
420.1 ALL MASONRY WORK SHALL BE IN CONFORMANCE WITH THE LATEST
EDITION OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES"
(TMS 402/ACI 530/ASCE 5) AND THE "SPECIFICATIONS FOR MASONRY
STRUCTURES" (TMS 602/ACI 530.1/ASCE 6) OF THE MASONRY SOCIETY.
420.2 ALL MASONRY WORK TO BE EXECUTED IN COLD WEATHER SHALL BE IN
CONFORMANCE WITH THE RECOMMENDATIONS FOR COLD WEATHER
CONSTRUCTION OF THE LATEST EDITION OF "BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES" (TMS 402/ACI 530/ASCE 5) AND
THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (TMS 602/ACI
530.1/ASCE 6) OF THE MASONRY SOCIETY WITH THE FOLLOWING ADDITION
TO THE REQUIREMENTS OF TMS 602/ACI 530.1/ASCE 6, SECTION 1.8-C: FOR
ALL CONDITIONS WHEN TEMPERATURES FALL BELOW 40 DEGREES F, THE
TEMPERATURE OF THE NEWLY LAID MASONRY OR NEWLY GROUTED
MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES (F) FOR A MINIMUM OF
24 HOURS USING THE METHODS DESCRIBED IN TMS 602/ACI 530.1/ASCE 6.
420.3 MORTAR SHALL CONFORM TO THE PROPORTION SPECIFICATION OF ASTM
C270, TYPE S.
420.4 GROUT SHALL CONFORM TO ASTM C476 AND AS FOLLOWS:
A. COMPRESSIVE STRENGTH (F'c) OF GROUT = F'm AS INDICATED BELOW
BUT NO LESS THAN 3,000 PSI.
B. SLUMP OF GROUT SHALL BE 8 TO 11 INCHES AS MEASURED ACCORDING
TO ASTM C143.
C. MAX. AGGREGATE SIZE SHALL BE 3/8" (AGGREGATE GRADED TO
PRODUCE FINE GROUT IN CONFORMANCE WITH ASTM C476 AND C404).
420.5 LIMIT CEMENTITIOUS MATERIALS IN MORTAR TO: PORTLAND CEMENT
CONFORMING TO ASTM C150 TYPE I; LIME CONFORMING TO ASTM C207;
MORTAR CEMENT CONFORMING TO ASTM C1329; AND MASONRY CEMENT
CONFORMING TO ASTM C91.
420.6 PROVIDE SOLID AND HOLLOW LOAD BEARING CONCRETE BLOCK UNITS
CONFORMING TO ASTM C90. FURNISH CONCRETE BLOCK WITH NET AREA
COMPRESSIVE STRENGTH AS SPECIFIED BY TABLE 2 OF TMS 602/ACI
530.1/ASCE 6, SECTION 1.4 B.2 BASED ON THE UNIT STRENGTH METHOD.
420.7 MINIMUM 28-DAY ULTIMATE COMPRESSIVE STRENGTH OF MASONRY:
A. F'm 1500 PSI
420.8 HORIZONTAL JOINT REINFORCING FOR ALL EXTERIOR AND LOAD BEARING
WALLS SHALL BE GALVANIZED TRUSS OR LADDER TYPE DUR-O-WAL, OR
EQUIVALENT AS APPROVED BY THE ENGINEER WITH 2-9 GAUGE
LONGITUDINAL WIRE AND 9 GAUGE CROSS WIRE, SPACED AT 16" CENTER TO
CENTER, UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL LAYERS OF
JOINT REINFORCEMENT IN THE FIRST TWO COURSES ABOVE AND BELOW A
MASONRY OPENING. PROVIDE LAP AS RECOMMENDED BY MANUFACTURER
WITH A MINIMUM OF 6". DISCONTINUE JOINT REINFORCING AT CONTROL
JOINTS. PROVIDE "L" SHAPE AND "T" SHAPE DUR-O-WAL AT ALL
INTERSECTION CORNERS WITH 8" MINIMUM LAP. SEE TYPICAL DETAILS.
420.9 PROVIDE "DOVE -TAIL" ANCHORS AT 16" OC VERTICALLY FO
R ALL MAOSNRY
PLACED ADJACENT TO CAST -IN -PLACE COLUMNS.
420.10 FULL BED AND HEAD JOINTS SHALL BE USED.
420.11 ALL MASONRY WALLS SHALL BE SECURELY BRACED UNTIL FLOOR OR ROOF
SYSTEM HAS BEEN INSTALLED AND HAS BECOME CAPABLE OF STABILIZING
THE WALLS.
420.12 GROUT SOLID ALL CELLS IN MASONRY UNITS INSTALLED BELOW GRADE.
420.13 GROUT SOLID ALL CELLS CONTAINING REINFORCING, AND WHERE
INDICATED ON PLANS AND SECTIONS.
420.14 PROVIDE FINE GROUT PER ASTM C476 WHEN WIDTH OF GROUT SPACE IS
LESS THAN 2". PROVIDE COARSE GROUT FOR GROUT SPACE WIDTHS 2" OR
GREATER. PROVIDE FINE GROUT WHEN REINFORCING HAS LESS THAN 1/2"
CLEARANCE.
420.15 PROVIDE CONTROL JOINTS IN MASONRY CONSTRUCTION PER THE TYPICAL
DETAILS. THE CONTRACTOR SHALL SUBMIT THE PROPOSED CONTROL JOINT
LAYOUT TO THE ARCHITECT FOR REVIEW AND APPROVAL. PROVIDE
MASONRY CONTROL JOINTS IN ACCORDANCE WITH THE FOLLOWING
GUIDELINES UNLESS OTHERWISE INDICATED ON DRAWINGS:
A. CONTROL JOINTS SHALL BE LOCATED AT A MAXIMUM SPACING OF 20
FEET ON CENTER IN THE WALL FIELD AND A MAXIMUM OF 10 FEET FROM
BUILDING CORNERS
B. LOCATE CONTROL JOINTS AT MAJOR HEIGHT CHANGES, CHANGES IN
WALL THICKNESS AND AT WALL OPENINGS.
C. CONTROL JOINTS IN PARAPETS SHALL BE SPACED AT 15 FEET ON
CENTER MAXIMUM. WHERE JOINTS IN PARAPETS CAN NOT BE ALIGNED
WITH JOINTS IN WALL FIELD, PROVIDE CONTROL JOINTS IN THE
PARAPET ONLY AT HALF THE WALL FIELD SPACING.
D. CONTROL JOINTS SHALL BE A MINIMUM WIDTH OF 3/8" AND SHALL
UTILIZE COMPRESSIBLE MATERIAL WITH A MINIMUM EXTENSIBILITY OF
60%.
420.16 PROVIDE CLEAN OUT AND INSPECTION HOLES AT BOTTOM OF MASONRY
WALL IN ACCORDANCE WITH MASONRY CODE AT REINFORCING IF HIGH LIFT
GROUTING (OVER 4 FEET HIGH) IS USED.
420.17 DEFORMED BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE
60. PROVIDE LAP SPLICES OF 48 BAR DIAMETERS MINIMUM. PROVIDE BAR
SPACERS AS REQUIRED TO PROPERLY LOCATE REINFORCING.
420.18 MASONRY COURSING SHOWN IN SECTION IS APPROXIMATE. REFER TO
PLANS AND ELEVATIONS FOR ACTUAL COURSING. COORDINATE ACTUAL
COURSING REQUIREMENTS WITH ARCHITECTURAL DRAWINGS.
420.19 ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A307.
510, STRUCTURAL STEEL
510.1 ALL STRUCTURAL STEEL WORK SHALL BE IN ACCORDANCE WITH ANSI/AISC
360-10 - "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS." LOADS,
FORCES AND MOMENTS INDICATED ARE SERVICE LEVEL AND ARE INTENDED
FOR USE WITH THE ALLOWABLE STRENGTH DESIGN
PROVISIONS OF THE
CODE.
510.2 GRADE OF STEEL
A. STRUCTURAL W SHAPES
ASTM A992
B. STRUCTURAL M, S, C, MC, AND L SHAPES
ASTM A36
C. STRUCTURAL HP SHAPES
ASTM A572,
GRADE 50
D. STEEL TUBES (HSS SHAPES)
ASTM A500,
GRADE B
E. STEEL PIPE (ROUND HSS)
ASTM A500,
GRADE B
F. PLATES AND BARS
ASTM A36
510.3 ALL WELDING SHALL BE IN ACCORDANCE WITH THE STRUCTURAL WELDING
CODE, AWS D1.1, LATEST EDITION, OF THE AMERICAN WELDING SOCIETY.
ELECTRODES SHALL BE E70XX FOR MANUAL ARC WELDING AND F7X-EXXX
FOR SUBMERGED ARC WELDING.
510A ALL STRUCTURAL STEEL FRAMES SHALL BE SECURELY BRACED UNTIL ALL
FLOOR SLABS, ROOF DECKS, AND SHEAR WALLS HAVE BEEN INSTALLED AND
BECOME CAPABLE OF STABILIZING THE FRAMES.
510.5 ALL STRUCTURAL STEEL WORK, EXCEPT PORTIONS OF MEMBERS TO BE
WELDED, FIELD BOLTED, GALVANIZED, OR FIREPROOFED, SHALL BE SHOP
PAINTED WITH PAINT CONFORMING TO STEEL STRUCTURES PAINTING
COUNCIL (SSPC) PAINT 25. APPLY PRIME PAINT ACCORDING TO SSPC PAINT
SYSTEM GUIDE NO. 7.00 CLEAN STEEL FREE OF LOOSE SCALE, RUST, OIL
AND GREASE. ADDITIONAL AREAS SHALL BE FIELD PAINTED AFTER WELDING.
510.6 BOLT AND WELD TESTING:
A. ALL SHOP AND FIELD BOLTS SHALL BE TESTED PER AISC
REQUIREMENTS.
B. ALL WELDS SHOULD BE VISUALLY INSPECTED.
510.7 LEVELING GROUT SHALL BE NON -SHRINK, NON-METALLIC TYPE, FACTORY
PRE -MIXED GROUT TESTED IN ACCORDANCE WITH CE-CRD-C621 OR ASTM
C109, WITH Pc OF NOT LESS THAN 5000 PSI.
510.8 ALL ANCHOR BOLTS SHALL BE ASTM A36 OR ASTM F1554, GRADE 36 AND A
MINIMUM 3/4" DIAMETER WITH A MINIMUM CONCRETE EMBEDMENT OF 12"
UNLESS NOTED OTHERWISE.
6% STRUCTURALLUMBER
610.1 ALL STRUCTURAL LUMBER WORK SHALL BE IN ACCORDANCE WITH THE
"NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" (NDS -
LATEST EDITION) PUBLISHED BY THE AMERICAN WOOD COUNCIL.
610.2 ALL STRUCTURAL LUMBER SHALL BE AS A MINIMUM NO. 2 GRADE SOUTHERN
PINE AND SHALL HAVE AT LEAST THE FOLLOWING MINIMUM ALLOWABLE
DESIGN STRESSES (NOT INCORPORATING THE SIZE ADJUSTMENT FACTOR
(CF)) AND MODULUS OF ELASTICITY AT A MAXIMUM MOISTURE CONTENT OF
19%:
A. Fb.(BENDING) 750 PSI
B. FV.(SHEAR) 175 PSI
C. Fc.(COMPRESSION) 1,250 PSI
D. Ft.(TENSION) 450 PSI
E. E 1,400,000 PSI
610.3 ALL LUMBER SHALL COMPLY WITH PS 20 "AMERICAN SOFTWOOD LUMBER
STANDARD" AND WITH THE APPLICABLE RULE OF INSPECTION AGENCIES
CERTIFIED BY AMERICAN LUMBER STANDARD. FACTORY -MARK EACH PIECE
OF LUMBER WITH GRADE STAMP OF INSPECTION AGENCY EVIDENCING
COMPLIANCE WITH GRADING RULE REQUIREMENTS.
610.4 STRUCTURAL STEEL PLATES, ANGLES, ETC., SHALL BE ASTM A36.
CONTRACTOR TO SUBMIT SHOP DRAWINGS ON ALL MISCELLANEOUS
METALS FOR REVIEW BY STRUCTURAL ENGINEER.
610.5 ALL BOLTS SHALL BE 3/4" DIAMETER ASTM A307 UNLESS NOTED OTHERWISE
WITH 2 WASHERS PER BOLT UNLESS OTHERWISE NOTED.
610.6 ALL LUMBER FOR SILL PLATES, TOP PLATES, AND OTHER WOOD WHICH MAY
BE EXPOSED TO WEATHER OR EARTH OR IN CONTACT WITH CONCRETE,
MASONRY, OR OTHER CEMENTITIOUS MATERIAL SHALL BE PRESSURE
TREATED WITH WATER -BORNE PRESERVATIVES. PRESSURE TREATMENT
SHALL COMPLY WITH REQUIREMENTS OF AWPA STANDARDS C2 AND LP-22.
610.7 PROVIDE NAILING PATTERN IN COMPLIANCE WITH THE DESIGN BUILDING
CODE'S RECOMMENDED FASTENING SCHEDULE WHEN JOINING TWO OR
MORE FRAMING MEMBERS.
610.8 ALTERNATE CONNECTION DETAILS MAY BE USED IF SUCH DETAILS ARE
SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL. HOWEVER, THE
ENGINEER SHALL BE THE SOLE JUDGE OF ACCEPTANCE AND THE
CONTRACTOR'S BID SHALL ANTICIPATE THE USE OF THOSE SPECIFIED
DETAILS SHOWN ON THE DRAWINGS THE CONTRACTOR IS RESPONSIBLE
FOR THE DESIGN OF SUCH ALTERNATE DETAILS WHICH HE PROPOSES.
620. STRUCTURAL WOOD PANELS/WOOD SHEATHING
620.1 FURNISH PANELS THAT ARE EACH FACTORY MARKED WITH A
CERTIFICATION STAMP EVIDENCING COMPLIANCE WITH GRADE AND SPAN
RATING REQUIREMENTS. THE CENTER -TO -CENTER SPACING IN INCHES
SHALL NOT EXCEED THE SPAN RATING STAMPED ON THE PANELS.
INSTALLATION OF THE PANELS SHALL BE IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE APA.
620.2 PANELS SHALL COMPLY WITH USDOC PS-1 OR PS-2 AND APA PRP-108 AND
SHALL MEET THE FOLLOWING REQUIREMENTS:
A. WALL SHEATHING:
1. MIN. THICKNESS = 5/8"
2. BOND CLASSIFICATION = EXPOSURE 1
3. GRADE = APA RATED SHEATHING
4. SPAN RATING = AS REQUIRED TO SUIT STUD SPACING
B. ROOF SHEATHING:
1. MIN. THICKNESS = 518"
2. BOND CLASSIFICATION = EXPOSURE 1
3. GRADE = APA RATED SHEATHING
4. SPAN RATING = AS REQUIRED TO SUIT JOIST/TRUSS SPACING
620.3 ALL PANELS WHICH HAVE ANY EDGE OR FACE PERMANENTLY EXPOSED TO
THE WEATHER SHALL BE CLASSED EXTERIOR, EXCEPT OPEN SOFFITS OR
ROOF SHEATHING EXPOSED ON THE UNDERSIDE MAY BE CLASSED
EXPOSURE1.
620.4 ALL ROOF PANELS SHALL HAVE THE END JOINTS LOCATED OVER
SUPPORTS AND SHALL HAVE THE ROWS STAGGERED ONE HALF PANEL
LENGTH FROM ADJACENT PANELS. PROVIDE 1/8" SPACE AT PANEL ENDS
AND EDGES.
620.5 ALL WALL PANELS SHALL HAVE THE END JOINTS LOCATED OVER
SUPPORTS.
620.6 THE USE OF ORIENTED STRAND BOARD STRUCTURAL PANELS PROHIBITED.
620.7 ALI„ ROOF STRUCTURAL PANELS SHALL BE NAILED WITH 10d SPIRAL OR
RING SHANK NAILS AT 6" OC AT ALL INTERMEDIATE SUPPORTS AND 4" OC
AT ALL ENDS AND EDGES. BLOCKING SHALL BE PROVIDED AT ALL
UNSUPPORTED PANEL EDGES.
620.8 ALL WALL STRUCTURAL PANELS SHALL BE NAILED TO WOOD SUPPORTS
WITH 8d COMMON NAILS AT 6" ON CENTER AT ALL ENDS, EDGES, AND
INTERMEDIATE SUPPORTS AND TO COLD -FORMED STEEL SUPPORTS WITH
#8 TEK SCREWS AT ALL ENDS, EDGES, AND INTERMEDIATE SUPPORTS.
FASTENER SPACING SHALL BE 4" ON CENTER AT CORNERS.
620.9 ALL PLYWOOD PANELS SHALL COMPLY WITH THE WIND UPLIFT
REQUIREMENTS OF NM519 FOR FULLY -WIND -RESISTIVE ROOF ASSEMBLIES
COMPLYING WITH UL CLASS 90 CLASSIFICATION.
635. WOOD TRUSSES
635.1 WOOD TRUSSES SHALL CONFORM TO THE MOST CURRENT APPLICABLE
EDITION OF THE DESIGN SPECIFICATIONS FOR LIGHT METAL PLATE
CONNECTED WOOD ROOF TRUSSES, OF THE TRUSS PLATE INSTITUTE, INC.
AND THE NATIONAL DESIGN SPECIFICATIONS FOR STRESS GRADE LUMBER
AND ITS FASTENING, OF THE NATIONAL FOREST PRODUCTS ASSOCIATION.
635.2 WOOD ROOF TRUSSES SHALL BE DESIGNED TO SUPPORT THE LOADS
INDICATED BELOW AT THE SPACING INDICATED ON THE DRAWINGS.
A. DEAD LOADS:
1. UNIFORM TOP CHORD
DEAD LOAD 15 PSF + MECH
EQUIP.
2. UNIFORM BOTTOM CHORD
DEAD LOAD 10 PSF
3. BOTTOM CHORD CONCENTRATED
LOAD AT ANY LOCATION
ON BOTTOM CHORD 300 LBS.
B. LIVE LOADS = SEE DESIGN CRITERIA GENERAL NOTES
C. LATERAL LOADS = SEE DESIGN CRITERIA GENERAL NOTES
635.3 THE DEFLECTION OF THE FLOOR AND ROOF TRUSSES UNDER THE
INDICATED LOADS AND AT THE SPAN AND SPACINGS SHOWN ON THE
CONTRACT DRAWINGS SHALL MEET THE FOLLOWING CRITERIA:
A. ROOF TRUSSES: THE DEFLECTION DUE TO THE TOTAL ROOF LOAD
SHALL NOT EXCEED THE SPAN LENGTH/240, THE DEFLECTION DUE TO
THE ROOF LIVE/SNOW LOAD SHALL NOT EXCEED THE SPAN LENGTH/360.
DETERMINATION OF THE DEAD LOAD DEFLECTION SHALL UTILIZE A TIME
DEPENDENT DEFORMATION (CREEP) FACTOR OF 2.0.
635.4 THE WOOD TRUSS MANUFACTURER SHALL SPECIFY AND PROVIDE ALL
BRACING AT TOP AND BOTTOM CHORDS REQUIRED TO STABILIZE THE ROOF
STRUCTURE DURING AND AFTER CONSTRUCTION, IN ADDITION TO THE
BRACING INDICATED ON THE STRUCTURAL DRAWINGS.
635.5 THE WOOD TRUSS MANUFACTURER SHALL SUBMIT STRUCTURAL
CALCULATIONS STAMPED BY A REGISTERED PROFESSIONAL ENGINEER
LICENSED TO PRACTICE IN THE STATE OF FLORIDA FOR ALL TRUSS TYPES,
WHICH INDICATE TRUSS CAPACITIES AND DEFLECTIONS.
635.6 ERECTION SHALL BE IN ACCORDANCE WITH TRUSS PLATE INSTITUTE
RECOMMENDATIONS.
635.7 NO SPLICES IN WEBS, CHORDS, OR OTHER LOAD CARRYING MEMBERS MAY
BE MADE WITHOUT REVIEW AND APPROVAL ON THE FINAL TRUSS SHOP
DRAWINGS WHICH INCLUDE SPECIFIC LOCATIONS AND DETAILS FOR ANY
SUCH SPLICE(S).
635.8 TEMPORARY TRUSS BRACING SHALL BE INSTALLED IN ACCORDANCE WITH
"RECOMMENDED DESIGN SPECIFICATIONS FOR TEMPORARY BRACING OF
METAL PLATE CONNECTED WOOD TRUSSES" (DSB-89) AND "COMMENTARY
AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING METAL
PLATE CONNECTED WOOD TRUSSES" (HIB-91). INSTALL ALL WEB BRACING
REQUIRED BY THE TRUSS DESIGNER. TEMPORARY BOTTOM CHORD WEB
BRACING SHALL REMAIN PERMANENTLY IN PLACE. THE BOTTOM CHORD
BRACING SHALL NOT EXCEED 10' FOR TRUSSES WHERE NO SHEATHING IS
ATTACHED TO THE TRUSS BOTTOM CHORD OR WITH TRUSS BOTTOM FILLER.
PROVIDE 2X4 LATERAL BRACING AT 36" ON CENTER UNDER PIGGYBACK
TRUSSES. AT TRUSSES REQUIRING WEB BRACING, PROVIDE 2X4 DIAGONAL
AT 20' MAX NAILED TO WEBS FROM ROOF TO BOTTOM CHORD. ALL BRACING
SHALL BE NAILED WITH 2-16D NAILS TO TRUSSES. FOR TRUSS SPANS
EXCEEDING 60'-0" SUBMIT BRACING DRAWINGS SIGNED AND SEALED BY A
REGISTERED ENGINEER IN THE STATE OF FLORIDA.
635.9 BOTTOM CHORD BEARING PARALLEL CHORD TRUSSES SHALL BE CLEARLY
MARKED IN A MANNER WHICH WILL AVOID INVERTED INSTALLATION IN
ACCORDANCE WITH THE TRUSS PLATE INSTITUTE, "NATIONAL DESIGN
STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION,"
ANSI/TPI 1 - LATEST EDITION.
635.10 THE WOOD TRUSS MANUFACTURER SHALL DESIGN AND SPECIFY ALL
CONNECTIONS AND CONNECTION COMPONENTS FOR TRUSS -TO -TRUSS
CONNECTIONS. ALL CONNECTIONS AND CONNECTION COMPONENTS SHALL
BE INDICATED ON THE FINAL SHOP DRAWINGS.
635.11 THE WOOD TRUSS MANUFACTURER SHALL REFER TO MECHANICAL AND
ELECTRICAL DRAWINGS FOR COORDINATION OF MECHANICAU ELECTRICAL
UNITS AND SPECIAL CONCENTRATED LOADS SUPPORTED BY THE WOOD
TRUSSES NOT INDICATED ON THE STRUCTURAL DRAWINGS.
635.12 WHERE MECHANICAL / ELECTRICAL LOADS ARE ATTACHED TO THE WOOD
TRUSSES, ATTACHED LOADS SHALL NOT EXCEED THE LOADS INDICATED IN
THE NOTES ABOVE. WHERE THE ACTUAL LOADS EXCEED THE LOADS
INDICATED ABOVE, THE WOOD TRUSS MANUFACTURER SHALL EITHER
PROVIDE ADDITIONAL FRAMING TO DISTRIBUTE THE LOADS TO CONFORM TO
THE LOADS INDICATED OR PROVIDE ADDITIONAL LOCALIZED CAPACITY IN
THE WOOD TRUSS DESIGN TO SUPPORT THE ACTUAL LOADS.
635.13 WHERE MULTIPLE PIPING LINES RUN PARALLEL, STAGGER THE PIPE
SUPPORT HANGERS AS REQUIRED TO COMPLY WITH THE LOADS INDICATED
ABOVE.
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY IELD INSPECTORS THAT
t;AAY, BC_NECES°A.RY IN ORDER TO.
jPLY WRH 1 G PLICAfti CODES:
a
w
x
f/1
z
w
J
U
L%
U
w
0-
W
V)
3
H
x
U
3
D_
0
H
z
w
0
0
Li
V)
O
a
a
w
0
O
z
z
0
O
Ix
I-
a
z
C
L�
C
i
z
C
L�
c;
CC
a
a
LL
C
z
a
c
LL
z
LL
Q
I-
C
z
a
G
z
a
a
F
U
If
C
c
u
C
L
D
L
L
F
c
F
c
t:
c
,,,`,,11,1,1un r1"aa4p
J ID iv "I
Ala
TLANTIC =* No. 0 ;
EM . ENGINEERING _
6501 Arlington Expressway 11
Building B, Suite 201 0* : ST T •�
Jacksonville, FL 32211 , • 0 R 1• P�
PH: 904,743.4633 FX:904.725.9293 '�,� ......
��
AE6 #317.106 ����s'Ot.WLt" ,,.•�`,
DAVID L WEBB PE 47180
t
e
R. Wulbern
Arvhitf-rt PA
AA. 0003433 Ilc
(904) 329.2510 tel
mbertawulbem.net
N
y
z
0
w
W
U
>
Q
Ix
w
0
0
U
of
LL
u.
t`
r
w
Q
O
N
p
o
<r 00
00
N
J
A r`
O
N
O
o I�l
z
W
U �O
z
U
W
7
x
x
m
a
x
o
Oo0-
goldco a
VERTIC L
....J cJi
to
Q
U)
CL 0
111411- O
<+�+ z
U w
v J
M �
Iti �
ti O)
N M
a xo
=o
'Z O LL
V Z LLT
Z aWgL)
Uj Qo
wa
= O
mUz°L)
z
0
w
O
Z
s.
J
I
rc
w
Z
w
W
J
o
z
H-
g
F--
H-
LU
LLJ
rn
SO
7
i
4 1/8"_
T-8 7/8"
1/2" 104
WF2.33 -- NOTE =
co
106
4 1 /8"
105
NOTE
---WF2.33
1—c-1—
II II II II II S6 J
------ - -.- - -.--
o
F4 Fa
F NOTE8 � I0— --WF2.33-----�LI L---
..
II
-------------._.._.._.._.._.
�LL f------—— _ ------------- ------- -----------
'
I
NOTE ---J L, r•J
I I
101 I I I I
S-3
I
NI I WF2.33
U_ I I
n
NOTE
ii
112
I � I
rJ L� F.D.
Fa.S
I I I I I SLOPE SLAB
Q I I I I I I TO DRAIN TYP I ! I
I I ! I
C4F3 I C1_I.'_.._.._.._.._.._.._.._._.._.._.._.._.._.._.._.._..i_.._.._.._.._.._.._.._.._.I._.._.._.._.._.._.._.._.._.._.._.i_.._._.._..—i._.._.._.._.._.._.._.._.._.._.._..i.._.._.._.._.._.._........
_I.._.._.. _.._.
I I I F.D r 1---- ---J
I I 00
N I I I I I I
L rJ I I r-- -----
I NOTE 1
I I I I I MOP SINK I I
I M rn I I CONTRACTION/CONSTRUCTION I I I F.D. i 112
S6
I JOINT TYP I I 6" I I
I I I I I I I
.._.._.._.._.._.._.._.._..+.._.._.._.._.._.._.._.._..`.._.._.._.._.._.._.._.._.._.._..t.._.._.._.._.._.._.._
S_3
I I I I I
- - - - - -I ( I I Fa Fa
f-----or r---!---1
I
I I
109
I S-5
HSS5X5X5/16 ON 3/4"X1i"X12" BASE
L
PLATE WITH (4) 314"DIA 1'-01.
�j
----
----------
I I
I
ANCHOR BOLTS (3) LOCATIONS
#
I
(
I
I
I'
J
111
w
I RECESS SLAB.
AND DEPTH
I
I
w ,
r
w
WOO
F7 I
I I
Q
�Z
I I
I
S 6 I
I �Z
N
I I
W.ISIZE
B. MANU
I
r--J
L--� F5 I
U
L) I I
�41/8"
41/8" I
U
U v
I I
I
I
I
----� — i---�
atJ
L�
L_, SO
F
F.D
F.D
I I
Nco
C3 L-------� C2 L--
----I C2
Q
7
C1 z
¢
— —
—
-------------- ----
-----------
I
I
TD
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J
NOTE 8 • ---ED
L—
I I --- ---J F4
L-------J v r`
L^____-- J F3 F3 F3 -dam' 106
107 r----I r— --I r---, S-4
S-5 C4 I I C41 I C41 Q I
I I I I I
n
NOTE 8 --- — NOTE 8 4 1/8" �
7 5/8" 7 5/8" 7 518"
-4 1/2"
CONTINUOUS WALL FOOTING SCHEDULE
MARK
WIDTH
DEPTH
LONGITUDINAL REINFORCING
TRANSVERSE REINFORCING
WF2.0
2'-0"
1'4'
(2) #5 CONT TOP AND BOTTOM
#3 TIES AT 16" OC
WF2.33
2'-4"
1'4"
(2) #5 CONT TOP AND BOTTOM
#3 TIES AT 16" OC
WF4.0
4'-0"
1'4'
(4) #5 CONT TOP AND BOTTOM
#3 TIES AT 16"OC
SPREAD FOOTING SCHEDULE
MARK
WIDTH
LENGTH
DEPTH
REINFORCING
F3
T-0"
3'-0"
T-4"
(4) #5 EACH WAY TOP AND BOTTOM
F4
4'-0"
4'-0"
1'-4"
(5) #5 EACH WAY TOP AND BOTTOM
F5
5'-0"
5'4"
V-4"
(6) #5 EACH WAY TOP AND BOTTOM
F7
T-0"
T-0"
1'-4"
(6) #6 EACH WAY TOP AND BOTTOM
F8
4'-0"
8'-0"
1'-4"
(5) #5 LONG WAY TOP AND BOTTOM
(11) #5 SHORT WAY TOP AND BOTTOM
F8.5
6'-0"
8'-8"
1'-4"
(7) #5 LONG WAY TOP AND BOTTOM
(10) #5 SHORT WAY TOP AND BOTTOM
FOUNDATION AND SLAB PLAN
SCALE: 1/4" = V-0"
NOTES:
1. 4" CONCRETE SLAB ON GRADE REINFORCED WITH 6X6-W1.4XW1.4 WWR ON VAPOR
RETARDER ON TERMITE TREATED COMPACTED FILL. VERIFY LOCATION OF
CONSTRUCTION/CONTRACTION JOINTS WITH ARCHITECT.
2. REFERENCE FINISH FLOOR ELEVATION = 0'-0". COORDINATE FLOOR ELEVATIONS,
SLOPES, AND RECESSES WITH ARCHITECTURAL AND CIVIL DRAWINGS.
3. TOP OF EXTERIOR FOOTING ELEVATION = 44" UNLESS NOTED OTHERWISE, TOP OF
EXTERIOR FOOTINGS SHALL BE MINIMUM 8" BELOW FINISH GRADE UNO.
4. STEP FOOTINGS BELOW WATER AND SANITARY PIPES. SEE TYPICAL DETAILS ON S-8.
5. EXTERIOR MASONRY WALLS SHALL BE REINFORCED WITH (1) #5 VERTICAL CENTERED
IN GROUTED CELL AT 2'-8" OC UNO. FILL ALL REINFORCED CELLS SOLID WITH 3000
PSI GROUT. SEE TYPICAL DETAILS ON S-9 FOR ADDITIONAL REQUIRED REINFORCING.
6. CONTINUOUS WALL FOOTINGS SHALL BE TYPE WF2.0 UNO.
7. SEE ARCHITECTURAL DRAWINGS FOR HEIGHT, WIDTH, AND LOCATION OF MASONRY
WALLS AND WALL OPENINGS.
8. 3 5/8" STUD FURRING ELEMENT. SEE SECTION 104/S-4 FOR FRAMING. DIMENSION IS
TO OUTSIDE FACE OF SHEATHING. PROVIDE MINIMUM 12" DEEP CONCRETE CURB
(TOP OF CONCRETE EL=+0'-4") REINFORCED WITH #4 CONTINUOUS AT 12" OC MAX
BENEATH STUDS - SEE TYPICAL DETAIL.
9. F.D. - DENOTES FLOOR DRAIN. COORDINATE LOCATION OF ALL FLOOR/HUB DRAINS
AND FLOOR SINKS WITH PLUMBING DRAWINGS. PROVIDE 2% SLOPE IN 4'-0" X 4'-0"
AREA AROUND FLOOR DRAINS UNO.
(V
(6) #6 VERTICAL
n
�SAT8"OC
NOTE 8
L
6"DIA X 8'-0" STEEL BOLLARD
FILLED WITH CONCRETE
SEE TYPICAL DETAIL
m
Ifl+a
108
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
' t,IIAY BE NECE32ARY IN QR05U TO:
comPIY.OfTH L A0PLICAnAC0DES,"
/4 ii[N1111
AT 8" OC
(8) #6 VERTICAL
U
iv #3 TIES AT 8" OC
C2 C3
CONCRETE COLUMN DETAILS
0'
0
F
¢
Z
¢
W
w
0
O
Lv
(n
O
a
a
0'
w
0
}
z
W
O
Of
¢
a
z
0_
O
J
O
z
W
W
U
a
0
w
0�
a
Z
0
w
in
w
m
F_
O
z
}
a
z
¢
a
z
z
w
z
z
0
U
z
O
w
Of
w
x
0
W
z
CLR F
0
U
I TIES AT 8" OC F
#6 VERTICAL <
O
W
z
a
Z
V
z
lY
0
w
"
wI
E ^.SF
� IS
ATLANTIC N
ENGINEERING" *
o
*.E
6501 Arlington Expressway•;
tj W
Building B, Suite 201
1
TA'I; F
Jacksonville, FL 32211
PH: 904.743.4633 FX:904.725.9295
�• •
'°� O P•:
11 t11S� •"� R•••,•�
11 `:
AEG #317.107
,11h„O,�'Vil.1„"`��``�,
DAVID L WEBB PE 47180
Re Wulbern
AA- 0003433 IIc
(904)329-2510 tel
mbenQwulbem.net
N
Z
z
o
cn
U
a
�
W
0
LL
W
Q
N
a
o
a0
N
J
W
n
0
N
J
O
,
o I�
z'0
in
Z
Y
W
Q
M
W
=
I—
a
O
=
0
U
O a
IL
0 g01dC0
111
VERTIC L
V
d
J
-6-+
U)
Ld
C� Lo
W
I"" M
O Y 0
Z
6
O
CD LL
z
0 Z)
� g L)
0�rA0L)
C0
00
m�z`°
J
0
Z
m
a
a
CL
°
Zm
W
O
v
a
in
°
Z
a
D
LU
J
p
z
H
LL
o
H
H
LU
LU
x
Cn
S-1
105
TRUSS BASE
SUPPORT
r- PARAPET:
- - ZONE 4: +/-97 PSF
ZONE 5: +/-110 PSF
H EL +18'-0"
H
N
H
H
WALL:
-� ZONE 4: +50 / -54 PSF
-� ZONE 5: +50 / -63 PSF
H
H
SEE CANOPY SHOP 1 F 2'-0"
DRAWINGS FOR TRUSS BASE
REACTIONS ON WOOD SUPPORT EL+10'-0"
TRUSSES � �y
-- OVERHANG: r�
1 1 34 PSF
INTERIOR- 182 PSF
• TRUSSES AT 24" OC
• REFER TO GENERAL NOTES FOR GRAVITY LOADS
• WIND PRESSURE/SUCTION INDICATED HERE ARE
BASED ON "COMPONENTS AND CLADDING"
• WIND PRESSURES ARE ULTIMATE
TYPICAL TOWER TRUSS WIND LOAD DIAGRAM
V VCIVIll1VV
COMPONENTS AND CLADDING
WIND PRESSURE DIAGRAM
a = 4'-0"
0
w Al 101
S-3
m
LL
0
a
0
N
m0
O
Ww
co
m
LL
0
a
0
U
TRUSS BEARING
EL+10'-4 1/211 UNO
103
TOP OF BEAM
EL +13'-0"
102
PRE FAB METAL
CANOPY SEE ARCH
FURRING AT TOWER
ELEMENT SEE WALL
SECTIONS
T041105PRE FAB METAL PRE FAB METAL
CANOPY SEE ARCH
CANOPY SEE ARCH
FURRING AT TOWER FURRING AT TOWER
ELEMENT SEE WALL
ELEMENT SEE WALL
106 SECTIONS
SECTIONS 1/2" UNO EL+10'-4
TRUSS BEARING S-4
L L. I
j
ROOF VENT
SEE ARCH
FURRING AT TOWER
ELEMENT SEE WALL
SECTIONS -7
I j j
EF'1 O II
ROOF VENT
250lbs'
250lbs1'
50' = SEE ARCH
III-- GIRDER TRUS
/4 1/4 j 1011/2"
L " 1'-33/4" 1'-111/4'
� '-3 1 /4„
6' 11 SPACES AT 2'-0" = 22'-0" 1„ 5/8 9 SPACE' - 1r „ 11 1/4" „ 2'-0" 2'-0" 2'-0" 2'-D"
SAT 2,_0„ _ 18,_0„ i '11 1- /4T-2 11 1 1/2 2' 2 0�/ 2,_0„ } 11 1/T��_ r i 107/8" 11 114 11 1/4
-� 1 1 /2" „
- ---- --- -- x - - - - - - - - - --- - ---'- --
II I I I I I II I I I I I I I TRUS
S PLACEMENT CRITICAL FOR KITCHEN EXHAUST DUCTS
RTU-2
9501bs -- -- — ---j II
j RT -3 2 2X8 BETWEEN TRUSSES WITH!
I I--
- - —
1 I 1 NOTE 6 j I 11 II I I � j II j Ij j SIMPSON LUS28-2 EACH END TYP"
RTU-1 950IbS I \
II II NO E 6
950 lbs _
NOTE 6 — —'— — —
II NOTE 1' II II II
(2) 2X8 BETWEEN TRUSSES WITH
NOTE 8 TYP SIMPSON LUS28-2 EACH END
TYPICAL AT ROOF TOP UNITS DRAG TRUSS MIN 2 PLY
--- - -- DRAG FORCES =420 PLF Ij ALLOWABLE _ -- -- -
--- ,-'' _
- -----------------------------------III-
IIIli
3/4"�11
l 1 1 1 3/4" 1 II II ROOF
---- j j jl HATCHI
- - TOP OF CMU WALL (2) 2X8 BETWEEN 1_ =—=L==
- _ ?------r EL+10'-0- TRUSSES WITHSIMPSON
EL+1V-0" ---- -- ---� S8 j Ij GIRDER TRUSS
TOP OF CMU WALL 1 LUS28-2 EACH END
L� 111 II 1 I i
i
ROOF VENT
2X4 X-BRIDGING AT
24"OC FOR BRACING OF SEE ARCH EF-3 O
WALL BELOW
i
----------------1- ----------------
- ---- --------------
PRE-ENGINEERED WOOD L NOTE 9 TYP
TRUSSES AT 24"OC UNO
IN. JX8 RAF TER 1 12479'
TRUSS BEARING
EL+10'-4 1/2" UNO
PRE FAB METAL S 4 SIM
PRE-ENGINEERED 107 CANOPY SEE ARCH
WOOD TRUSSES AT S-5
24"OC MAX UNO7 FURRING AT TO ER
110 ELEMENT SEE ALL
n � SECTIONS
COMPONENTS AND
CLADDING WIND
PRESSURES
TRIBUTARY
ROOF ZONE
WALL ZONE
PARAPET ZONE
AREA (SF)
1
2
3
4
5
4
5
10
+28/-57
+52/-95
+52/-95
+52/-56
+52-69
+46/-51
+46/-64
20
+22/-55
+50/-85
+50/-85
+50/-54
+50/-63
+44/-48
+44/-59
50
+20/-54
+47/-72
+47-72
+471-51
+47/-59
+41/-45
+41/-53
100
+19/-52
+44/-62
+44/-62
+441-49
+44/-54
+38/-43
+38/-48
NOTES:
1. ALL LOADS ARE IN POUNDS PER SQUARE FOOT (PSF).
2. (+) DENOTES PRESSURE, (-) DENOTES SUCTIONS.
3. "a" SHALL BE 10% OF LEAST HORIZ DIMENSION OR 0.4h, WHICHEVER IS
SMALLER, BUT NOT LESS THAN 4% OF LEAST HORIZ DIMENSION OR 3'-0".
4. "h" = MEAN ROOF HEIGHT.
CB-1, TOP OF BEAM EL +1 V-0"
CONCRETE
BEAM SCHEDULE
MARK
WIDTH
DEPTH
REINFORCING
TIES
CB-1
7 5/8"
2'-0'
(6) #5
#3 TIES AT 8" OC
CB-2
7 5/81'
3'-0"
(8) #6
#3 TIES AT 8" OC
CB-3
7 5/8"
2'-0"
(6) #6
#3 TIES AT 8" OC
COMPONENTS AND CLADDING
OVERHANG
LOADS
EFFECTIVE OVERHEAD
ZONE
AREA (FT 2)
2
3
10
57/-97
57/-97
20
55/-94
55/-94
50
52/-90
52/-90
100
1
49/-87
49/-87
NOTES
1. TABULATED COMPONENT AND CLADDING PRESSURES (Pult)
HAVE BEEN CALCULATED IN ACCORDANCE WITH THE
DESIGN BUILDING CODE PER NOTE 100.1 BASED ON
ULTIMATE DESIGN WIND SPEED (Vult) PER NOTE 100.3A
AND SHOULD BE USED IN CONJUNCTION WITH ASCE 7-10
LOAD COMBINATIONS, TABULATED PRESSURES CAN BE
CONVERTED TO NOMINAL VALUES BY MULTIPLYING BY 0.6.
ROOF FRAMING PLAN
SCALE: 1/4" = V-0"
NOTES:
1. 5/8" APA RATED EXPOSURE 1, 40120 SPAN RATING PLYWOOD ROOF SHEATHING.
ATTACH PLYWOOD WITH 10d SPIRAL OR RING SHANK NAILS AT 6" O.C. AT
INTERMEDIATE SUPPORTS AND 4" O.C. AT ALL ENDS AND EDGES.
2. PROVIDE 2X6 MINIMUM BLOCKING AT ALL RIDGES, HIPS, VALLEYS, EAVES, AND
UNSUPPORTED PLYWOOD PANEL EDGES.
3. TRUSS MANUFACTURER SHALL PROVIDE ALL BRIDGING AND BLOCKING
REQUIRED TO STABILIZE THE TRUSSES.
4. ALL METAL CONNECTORS THAT ARE IN CONTACT WITH PRESSURE TREATED
WOOD SHALL BE STAINLESS STEEL OR HOT -DIPPED GALVANIZED. CONTRACTOR
SHALL VERIFY COATING REQUIREMENTS AND COMPATIBILITY WITH TREATED
WOOD AND METAL CONNECTOR MANUFACTURER.
5. WHERE MULTI -PLY TRUSSES ARE INDICATED, TOP CHORDS SHALL BE FASTENED
TOGETHER WITH 1/2"DIA BOLTS AT 48"OC OR AS SPECIFIED BY THE TRUSS
MANUFACTURER.
6. DESIGN TRUSSES FOR INDICATED EQUIPMENT WEIGHTS. VERIFY SIZE AND
LOCATION OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS. REFER
TO MECHANICAL DRAWINGS FOR SIZE AND LOCATIONS OF ROOF OPENINGS AND
PENETRATIONS, ROOF TOP CURBS SHALL BE PROVIDED BY MECHANICAL
EQUIPMENT SUPPLIER.
7. DIMENSIONS ARE TO EXTERIOR FACE OF STUD UNLESS NOTED OTHERWISE
8. WOOD BRIDGING. SEE TYPICAL BRIDGING DETAIL ON S-10.
109
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY -FIELD INSPECTORS THAT
•r R�
iAAY.B[,.NECES°,RY.INQRCE,RTO i
C.Q"fiP V11THALL APPLICAr.14C0VES;
108
0
W
N
z
Of
W
J
J
Q
U
U
W
a
N
W
3
r
_
U
3
0
W
F-
Q
z
Q
w
F-
0
LL;
0
a
a
W
O
z
z
a
o:
w
a
a
z
C
C
LL
C
c
LL
C
C
a
a
LL
Q
0
c
s
c
L
U
u
0
F
C
F
i
C
1
R. Wulbern
Architect PA
AA-0003433 lit
(904)329-2510 101 -
rebertQwUlbem.nel
1n
z
z
NY
U
r
W
0
Q.
w
Q
N
o
aL
Go
Go
N
�
O
N
J
C)
0 I�
z,0
z
Y
W
oDz
U
O 0
EL
rI� goldco
.
VERTIC L
V
J
a-+
Z
C4
Q
W
°'
O16
Y
Z
,-
O
Z�
C)
0
WrA
U
LU
v
00
00
J
1,,11,11n1unni,,.,,.
'
TLANTIC
ENGINEERING
*
N
�'.•-;
:
i
�`�
6501 Arlington Expressway
1
�0 �:
.•
Building B, Suite 201
Jacksonville, FL 32211
� STA F
••:'4 Rapp:•'•
's 0��
PH: 904.743.4633 FX:904.725.9295
��,
1Z,,
• ....
Gv
/'0NA '
AES #317.107
`1,1 101
DAVIT L WEBB PE 47180
J
0
N
i
rn
V
a
N
z
�
1
C
z
G
Q
a
LL
LL
W
H
O
O
C
Z
s
H
W
N
S2
TOP OF CMU
EL +16-4" —
5/8" PLYWOOD WALL
SHEATHING ON VAPOR
BARRIER
SIMPSON A34 AT
EACH TRUSS
ATTACHED WITH (8)
8d X 1 1/2" NAILS
CONT PT (2) 2X8 TOP
PLATE WITH 1/2" DIA
ANCHOR BOLT AT 24" OC
(12" EMBEDMENT) WITH 3"
DIA WASHERS
3 5/8", 16 GA CFSF STUDS
AT 24" OC CONNECT TO
WALL WITH 1/4" DIA
TAPCON AT 24" OC MAX-
CMU WALL
VENEER SEE ARCH
TOP OF BEAM
EL +13'-0"
BLOCKING AND ATTACHMENT
PER CANOPY MANUF
BOTOTM OF
BEAM EL +10'-0"
PREFAB METAL
CANOPY SEE AI
BLOCKING AS REQUIRED
AT ROOF VENT
2X BLOCKING FOR
SHEATHING ATTACHMENT
TYPICAL
UPLIFT CONNECTOR TYPE 1
SEE SCHEDULE
—16" CMU BOND BEAM WITH
(4) #5 CONT
SIMPSON HETA24 STRAP AT 24" OC
WITH 4" EMBED IN WALL AND
(9) 10d X 1 1/2" NAILS THROUGH
SHEATHING TO RAFTER
UPLIFT AND SHEAR CONNECTOR
BY TRUSS MANUF
CONT 2X6 SLEEPER AT 24" OC MAX
ATTACHED THRU SHEATHING TO EACH
TRUSS WITH (2) #10X4" SCREWS
PRE-ENGINEERED WOOD
OVERFRAMING TRUSSES AT 24" OC
VF
ROOF SHEATHING CONT UNDER
OVERFRAMING SLOT AS NEEDED
FOR TRUSS TO TRUSS CONNECTION
PLYWOOD ROOF
r SHEATHING
1 2X8 AT 24"OC
L PROVIDE 2X8
BLOCKING AT 24"OC
SIMPSON LUS26 HANGER
EACH END EACH RAFTER
ATTACHED WITH (4) 10d NAILS
TO NAILER AND RAFTER
(1) PT2X8 NAILER TOP WITH (2)
DIA ADHESIVE ANCHORS
AT 24" OC WITH 6 3/4"
EMBEDMENT
8"X36" CONCRETE BEAM CB-2
EJ
CONCRETE
BARRIER CURB
FINISH GRADE
OR PAVEMENT
SEE CIVIL
L SIMPSON HETA24 STRAP AT 24" OC
WITH 4" EMBED IN WALL AND
(9) 10d X 1 1/2" NAILS THROUGH
SHEATHING TO BLOCKING
ZPREENGINEERED WOOD
TRUSSES SEE PLAN.
2X4 BLOCKING AT 24" OC
(1) PT2X8 NAILER TOP WITH (2)
3/4" DIA ADHESIVE ANCHORS
AT 24" OC WITH 6 3/4"
EMBEDMENT
8"X36" CONCRETE BEAM CB-2
STOREFRONT SYSTEM
SEE ARCH
(2) #5 CONT
#5 DOWELS AT 24" OC
CONCRETE SLAB
SEE PLAN
d
SECTION 101
SCALE: 3/4" = V-0" S-3
FILL ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
CONCRETE FOOTING
SEE PLAN
5/8" PLYWOOD WALL
SHEATHING ON VAPOR
BARRIER
SIMPSON A34 AT
EACH TRUSS
ATTACHED WITH (8)
8d X 1 1/2" NAILS
CONT PT (2) 2X8 TOP
PLATE WITH 1/2" DIA
ANCHOR BOLT AT 24" OC
(12" EMBEDMENT) WITH 3"
DIA WASHERS
TOP OF CMU
EL+164'-
3 5/8", 16 GA CFSF STUDS
AT 24" OC CONNECT TO
WALL WITH 1/4" DIA
TAPCON AT 24" OC MAX-
CMU WALL
VENEER SEE ARCH
TOP OF BEAM
EL +13'-0"
BLOCKING AND ATTACHMENT
PER CANOPY MANUF
TRUSS BEARING
EL SEE PLAN —
BOTOTM OF
BEAM EL +10'-0"
PREFAB METAL
CANOPY SEE Al
EJ
CONCRETE
BARRIER CURB
FINISH GRADE
OR PAVEMENT
SEE CIVIL-
BLOCKING AS REQUIRED
AT ROOF VENT
2X BLOCKING FOR
SHEATHING ATTACHMENT
TYPICAL
UPLIFT CONNECTOR TYPE 1
SEE SCHEDULE
SECTION 102
SCALE: 3/4" = V-0" S-3
CONNECTOR TYPE 3
SEE SCHEDULE
CONNECTOR TYPE 2
SEE SCHEDULE
(1) P72X8 NAILER TOP AND
BOTTOM WITH (2) 3/4" DIA
ADHESIVE ANCHORS AT 24" OC
WITH 6 3/4" EMBEDMENT
8"X36" CONCRETE BEAM CB-2
STOREFRONT SYSTEM
SEE ARCH
(2) #5 CONT
#5 DOWELS AT 24" OC
CONCRETE SLAB
SEE PLAN
9 5 00
FILL ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
CONCRETE FOOTING
SEE PLAN
16" CMU BOND BEAM WITH
(4) #5 CONT
UPLIFT AND SHEAR CONNECTOR
BY TRUSS MANUF
CONT 2X6 SLEEPER AT 24" OC MAX
ATTACHED THRU SHEATHING TO EACH
TRUSS WITH (2) #10X4" SCREWS
ROOF SHEATHING CONT UNDER
OVERFRAMING SLOT AS NEEDED
FOR TRUSS TO TRUSS CONNECTION
PRE-ENGINEERED WOOD
OVERFRAMING TRUSSES AT 24" OC
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN
2X4 BLOCKING AT 24" OC
TOP OF BEAM
EL +16 4'
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 3/4" EMBED —
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN
16" CMU BOND BEAM
WITH (4) #5 CONT
TOP OF BEAM
EL +13-0
TRUSS ATTACHMENT
BY TRUSS MANUF
TOP OF BEAM
EL+11-0" —
/ EL SEE ARCH
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 3/4" EMBED
BOTTOM OF BEAM
EL+9'-0"
CONT 2X4 FASCIA
ATTACHED TO EACH TRUSS
WITH (2) #10 X 3" SCREWS
FINISH GRADE
OR PAVEMENT
SEE CIVIL
#5 DOWEL AT 16" OC
f`
LIGHT BAND SEE ARCH
CONT PT2X8 TOP PLATE WITH 1/2" DIA
ADHESIVE ANCHOR BOLTS AT 24" OC
(12" EMBEDMENT) WITH 3" DIA
WASHERS
24" CMU BOND BEAM
WITH (6) #5 CONT
CMU WALL
PLYWOOD ROOF
SHEATHING
SIMPSON HETA24 STRAP AT 24" OC
WITH 4" EMBED IN WALL AND
(9) 10d X 1 1/2" NAILS THROUGH
SHEATHING TO BLOCKING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN.
2X4 BLOCKING AT 24" OC
(1) PT2X8 NAILER TOP WITH (2)
3/4" DIA ADHESIVE ANCHORS
AT 24" OC WITH 6 3/4"
EMBEDMENT
8"X24" CONCRETE BEAM CB-3
THESE PLANS AND ALL PROPOSED W09K
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
,` C.IAY BC NECESE4RY [N,ORDER,-TO
COMPLY WRIH � L,t`1PPl.I 0_-; CODES:
�— STOREFRONT SYSTEM
SEE ARCH
CMU BLOCK SILL WITH (2) # 5
CONT DOWEL INTO CONCRETE
COLUMNS (EACH SIDE)
EJ
/ CONCRETE SLAB
r/ co SEE PLAN
�
FILL ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
CONCRETE FOOTING
SEE PLAN
0
w
V)
fn
Z
D:
J
J
¢
0
M
0
w
a
(n
0
3
H
0
v_
i
Of
O
h
z
ZF
Ld
w
0 O
Li
(n
O
EL
a
w
O
z
z
0
U_
it
I-
0_
z
O
J
O
1
z
0
w
O
0
0
D-
w
o-
0
Z
0
w
(n
w
m
0
0
z
r
,,tttuu uurrpgr
SECTION 103
SCALE: 3/4„ = 1,-0„ S-3 QQ ;
�g, ATLANTIC N 180
ENGINEERING-' * c
W - h _
6501 Arlington Expressway � � S• 1
Building B, Suite 201 % 0� ST�T O
Jacksonville, FL 32211 F4
PH: 904.743.4633 FX:904.725.9295 %ass •••0 RR.% •�
AES #317-107 r/OAfALrrt p�,•
DAVID L WEBB PE 47180
R. Wulbern
Architect PA
AA • 0003433 Ile
(904)329.2510 tel
robert@wulbemmet
0
rn
z
0
N
V-a
U)
>
a
(L
a
Uj
X
w
0:
0
IrLL
w
Q
N
0
e �
J �
N
`0
J
W
^
O
N
J
O
o I�
z "o
w
Z
Q
W
w
=
FW—
a
o
0
U
O 0
1L
goldco
VERTIC L
V
V
J
U)
C4
U
m Q
C4
Q LU
LU
a r M
O Yo
Z
O
CD
Z � �
o
O=
&n O
CD J
in
0
N
0
to
b
fA
Z
O
0
U
W
w
o
J
Z
�
o
0
F-
H-
LLI
w
N
S-3
TOP OF CMU
EL +16'-4" —
TOP OF BEAM
EL +1 T-0"
BLOCKING AND ATTACHMENT
PER CANOPY MANUF
TRUSS BEARING
EL SEE PLAN —
5/8" PLYWOOD WALL
SHEATHING ON VAPOR
BARRIER
SIMPSON A34 AT
EACH TRUSS
ATTACHED WITH (8)
8d X 1 1/2" NAILS
CONT PT (2) 2X8 TOP
PLATE WITH 1/2" DIA
ANCHOR BOLT AT 24" OC
(12" EMBEDMENT) WITH 3"
DIA WASHERS
3 5/8", 16 GA CFSF STUDS
AT 24" OC CONNECT TO
WALL WITH 1/4" DIA
TAPCON AT 24" OC MAX —
PREFAB METAL
CANOPY SEE Al
VENEER SEE ARCH
3 5/8", 16 GA TRACK WITH (2)
1/2" DIA TAPCONS AT 24" OC
WITH 2" EMBED
CONCRETE
BARRIER CURB
FINISH GRADE
OR PAVEMENT
SEE CIVIL
(3) # 4 CONT
�L
1,
I►/
��
,/l
,
.
—I
BLOCKING AS REQUIRED
AT ROOF VENT
2X BLOCKING FOR
SHEATHING ATTACHMENT
TYPICAL
UPLIFT CONNECTOR TYPE 1
SEE SCHEDULE
CONNECTOR TYPE 3
SEE SCHEDULE
CONNECTOR TYPE 2
SEE SCHEDULE
(1) PT2X8 NAILER TOP AND
BOTTOM WITH (2) 3/4" DIA
ADHESIVE ANCHORS AT 24" OC
WITH 6 3/4" EMBEDMENT
32" CMU BOND BEAM
WITH (8) #5 CONT
CMU WALL
EJ
SECTION rl04
SCALE: 3/4" = 1'-0" S 4
CONCRETE SLAB
SEE PLAN
FILL ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
CONCRETE FOOTING
SEE PLAN
16" CMU BOND BEAM WITH
(4) #5 CONT
UPLIFT AND SHEAR CONNECTOR
BY TRUSS MANUF
CONT 2X6 SLEEPER AT 24" OC MAX
ATTACHED THRU SHEATHING TO EACH
TRUSS WITH (2) #10X4" SCREWS
ROOF SHEATHING CONT UNDER
OVERFRAMING SLOT AS NEEDED
FOR TRUSS TO TRUSS CONNECTION
PRE-ENGINEERED WOOD
OVERFRAMING TRUSSES AT 24" OC
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN.
2X4 BLOCKING AT 24" OC
5/8" PLYWOOD WALL
SHEATHING ON VAPOR
BARRIER
SIMPSON A34 AT
EACH TRUSS
ATTACHED WITH (8)
8d X 1 1/2" NAILS
CONT PT (2) 2X8 TOP
PLATE WITH 1/2" DIA
ANCHOR BOLT AT 24" OC
(12" EMBEDMENT) WITH 3"
DIA WASHERS
TOP OF CMU
EL +16'-4" —
3 5/8", 16 GA CFSF STUDS
AT 24" OC CONNECT TO
WALL WITH 1/4" DIA
TAPCON AT 24" OC MAX —
TOP OF BEAM
EL +13'-0"
BLOCKING AND ATTACHMENT
PER CANOPY MANUF
TRUSS BEARING
EL SEE PLAN —
PREFAB METAL
CANOPY SEE ARCI-
VENEER SEE ARCH
TOP OF BEAM
EL +8'-0"
FUR -OUT ELEMENT BEYOND
VENEER SEE ARCH
CONCRETE
BARRIER CURB
FINISH GRADE
OR PAVEMENT
SEE CIVIL —
BLOCKING AS REQUIRED
AT ROOF VENT
2X BLOCKING FOR
SHEATHING ATTACHMENT
TYPICAL
UPLIFT CONNECTOR TYPE 1
SEE SCHEDULE
CONNECTOR TYPE 3
SEE SCHEDULE
CONNECTORTYPE2
SEE SCHEDULE
(1) PT2X8 NAILER TOP AND
BOTTOM WITH (2) 3/4" DIA
ADHESIVE ANCHORS AT 24" OC
WITH 6 3/4" EMBEDMENT
CMU LINTEL SEE SCHEDULE
STOREFRONT SYSTEM
SEE ARCH
CMU BLOCK SILL WITH (2) # 5
CONT DOWEL INTO CONCRETE
COLUMNS (EACH SIDE)
EJ
CONCRETE SLAB
SEE PLAN
s� Z $ A
10'
9 z FILL ALL CELLS BELOW
a a FINISH FLOOR SOLID WITH
1 ' 3000 PSI GROUT
d $
(3) # 4 CONT CONCRETE FOOTING
SEE PLAN
•
SECTION 105
SCALE: 3/4" = V-0" S 4
16" CMU BOND BEAM WITH
(4) #5 CONT
UPLIFT AND SHEAR CONNECTOR
BY TRUSS MANUF
CONT 2X6 SLEEPER AT 24" OC MAX
ATTACHED THRU SHEATHING TO EACH
TRUSS WITH (2) #10X4" SCREWS
ROOF SHEATHING CONT UNDER
OVERFRAMING SLOT AS NEEDED
FOR TRUSS TO TRUSS CONNECTION
PRE-ENGINEERED WOOD
OVERFRAMING TRUSSES AT 24" OC
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN.
2X4 BLOCKING AT 24" OC
TOP OF CMU
EL +16'-4"
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 3/4" EMBED —
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN
32" CMU BOND BEAM
WITH (8) #5 CONT
TRUSS ATTACHMENT /
BY TRUSS MANUF
EL SEE ARCH
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 314" EMBED —
CONT 2X4 FASCIA
ATTACHED TO EACH TRUSS
WITH (2) #10 X 3" SCREWS
FINISH GRADE
OR PAVEMENT
SEE CIVIL
CONT PT2X8 TOP PLATE WITH 112"
DIA ADHESIVE ANCHOR BOLTS AT
24" OC WITH 12" EMBEDMENT WITH
3" DIA WASHERS
� ' 16" CMU BOND BEAM WITH
(4) #5 CONT
24" CMU BOND BEAM WITH
►' (6) #5 CONT AT MANSARD
LOCATIONS
(•; PLYWOOD ROOF
VI SHEATHING
CONNECTOR TYPE 3
1114 �_ SEE SCHEDULE
TRUSS BEARING
rEL SEE PLAN
PRE-ENGINEERED WOOD
I TRUSSES SEE PLAN.
VCONNECTORTYPE2
IM
SEE SCHEDULE
(1) PT2X8 NAILER TOP AND
BOTTOM WITH (2) 3/4" DIA
ADHESIVE ANCHORS AT 24" OC
WITH 6 3/4" EMBEDMENT
I
I
I
I
I
-- CMU WALL
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY WELD INSPECTORS THAT
' , �,IA"� BG NECESSARY Ill �RDEId TO ;
CO"APLYVYI7Hi',�LLt` PLICq.14COVES
I
EJ
CONCRETE SLAB
SEE PLAN
A
FILL ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
CONCRETE FOOTING
SEE PLAN
0
w
x
to
z
w
J
J
cn
U
w
a
4
3
H
U
3
0:
O
w
z
LU
w
O
N
O
a
a
w
C
O
}
z
4
F
a
a
a
z
a
C
L4
C
3
2
c
II
C
C
a
0
0
a
0
L
L
L
0
F
F
t
5
L
2
R. Wulbern
Architect PA
AA - 0003433 Ilc
(9041329-2510 tal
robert@wulbem.net
(7
rn
Z
z
N
Y
U
W
>
Q
0
iUj t
w
0
O
W
n
.4
¢
v
N
0
a
N
0
fN
J
O
0 I�
z NO
Z
Y
W
fX
i
is a
X
D
U
Q 0
d
z
0
w
0_
w
x
w
z
z
z
0
U
0
F
m
O
Z
0
Z
O
Z
a
n
SECTION 106
J♦L L.ty.
SCALE: 3/4" = V-0" S-4 0 •• S ' ., �
s. ATLANTIC 0. 80
06.
_ ENGINEERING:: *' �,yI
6501 Arlington Expressway ``� rl l ;•;
Building B, Suite 201 ��% STATE�F ;
Jacksonville, F� 32211 -� '•;°4 0 R % ID p:�
PH: 904.743.4633 FX:904.725.9295 '�, �p •.......
!v ��
AES 9317.107 ,,VV �Ort rWi:'t,t`„t•',,,
DAVID L WEBB PE47180
0 gq!dCo ..
VERTIC L
i--%
O
V
W
.! `
J
CM
10
^' z
N
Q W
O Yo
Z� �
O
Z� ��
a W U) Z
YOO �Z)o
0 _
WOro0
A/ y� a J
moZLo
��
J
0
N
b
Z
N
O
z
U
o
LrU^
/
Cn
U
N
w
J
z
1
_—
o
0
I—
W
W
S-4
TOP OF CMU
EL +16'-4" —
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 3/4" EMBED —
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN
TRUSS ATTACHMENT
BY TRUSS MANUF —
TOP OF BEAM
EL +11-0"
EL SEE ARCH
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 3/4" EMBED
CONT 2X4 FASCIA
ATTACHED TO EACH TRUSS TOP OF BEAM
WITH (2) #10 X 3" SCREWS EL +9'-D"
THIN BRICK
SEE ARCH -
FINISH GRADE
OR PAVEMENT
SEE CIVIL
CONT PT2X8 TOP PLATE WITH 1/2"
DIA ADHESIVE ANCHOR BOLTS AT
24" OC WITH 12" EMBEDMENT WITH
3" DIA WASHERS
24" CMU BOND BEAM WITH
(6) #5 CONT
24" CMU BOND BEAM
WITH (6) #5 CONT
CONNECTOR TYPE 3
SEE SCHEDULE
CONNECTORTYPE2
SEE SCHEDULE
(1) PT2X8 NAILER TOP AND
BOTTOM WITH (2) 3/4" DIA
ADHESIVE ANCHORS AT 24" OC
WITH 6 3/4" EMBEDMENT
8"X24" CONCRETE BEAM CB-1
STOREFRONT SYSTEM
SEE ARCH
CMU BLOCK SILL WITH (2) # 5
CONT DOWEL INTO CONCRETE
COLUMNS (EACH SIDE)
CMU WALL
b
a
°
•, •
e,
°e
SECTION 107
SCALE: 3/4" = V-0" S-5
EJ
CONCRETE SLAB
SEE PLAN
a A W ^
FILL ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
CONCRETE FOOTING
SEE PLAN
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN.
TRUSS BEARING
rEL SEE PLAN
5/8" PLYWOOD WALL
SHEATHING ON VAPOR
BARRIER
SIMPSON A34 AT
EACH TRUSS
ATTACHED WITH (8)
8d X 1 1/2" NAILS
CONT PT (2) 2X8 TOP
PLATE WITH 1/2"DIA
ANCHOR BOLT AT 24" OC
(12" EMBEDMENT) WITH 3"
DIA WASHERS
3 5/8", 16GA TRACK WITH
(2) #10 X 3" SCREWS AT
EACH TRUSS
TOP OF CMU
EL +16'-4" --i
3 5/8", 16 GA CFSF STUDS
AT 24" OC WITH
BLOCKING AT 48"OC —
16" CMU BOND BEAM WITH
(4) #5 CONT
TOP OF BEAM
EL +13-0"
SIMPSON HETA24
STRAP AT 24" OC WITH
4" EMBED IN WALL AND
(9) 10d X 1 1/2" NAILS
THROUGH SHEATHING
TO BLOCKING
VENEER SEE
3 5/8", 16 GA TRACK WITH (2)
1/2" DIA TAPCONS AT 24" OC
WITH 2" EMBED
CONCRETE
BARRIER CURB
BLOCKING AS REQUIRED
AT ROOF VENT
2X BLOCKING FOR
SHEATHING ATTACHMENT
TYPICAL
UPLIFT CONNECTOR TYPE 1
SEE SCHEDULE
2X4 BLOCKING AT 24" OC
(1) PT2X8 NAILER TOP WITH (2)
3/4" DIA ADHESIVE ANCHORS AT
24" OC WITH 6 3/4" EMBEDMENT
16" CMU BOND BEAM
WITH (4) #5 CONT
CMU WALL
1
EJ
FINISH GRADE N
OR PAVEMENT
CONCRETE SLAB
SEE CIVIL
— a
i
SEE PLAN
•g
Q
{
F
• z
10..
4 z
X.iFILL
(
ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
(3) # 4 CONT
"
E
° %
CONCRETE FOOTING
SEE PLAN
#4 + HK AT 24"OC
• i , i^
•
SECTION 108
SCALE: 3/4" = V-0" S-5
16" CMU BOND BEAM WITH
(4) #5 CONT
UPLIFT AND SHEAR CONNECTOR
BY TRUSS MANUF
CONT 2X6 SLEEPER AT 24" OC MAX
ATTACHED THRU SHEATHING TO EACH
TRUSS WITH (2) #10X4" SCREWS
ROOF SHEATHING CONT UNDER
OVERFRAMING SLOT AS NEEDED
FOR TRUSS TO TRUSS CONNECTION
PRE-ENGINEERED WOOD
OVERFRAMING TRUSSES AT 24" OC
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN.
TOP OF BEAM
EL +16'-4"
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 3/4" EMBED —
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN
16" CMU BOND BEAM
WITH (4) #5 CONT
TOP OF BEAM
EL +1 T-0
TRUSS ATTACHMENT
BY TRUSS MANUF
EL SEE ARCH
CONT PT2X8 WITH (2) 3/4"DIA
ADHESIVE ANCHORS AT
24"OC WITH 6 3/4" EMBED —
CONT 2X4 FASCIA
ATTACHED TO EACH TRUSS
WITH (2) #10 X 3" SCREWS
FINISH GRADE
OR PAVEMENT
SEE CIVIL —
e
•a
•° 41 :4111
SECTION 1 g
SCALE: 3/4" = V4 S-5
CONT PT2X8 TOP PLATE WITH 1/2"
DIA ADHESIVE ANCHOR BOLTS AT
24" OC WITH 12" EMBEDMENT WITH
3" DIA WASHERS
24" CMU BOND BEAM WITH
(6) #5 CONT
(1) PT2X8 NAILER TOP WITH (2)
3/4" DIA ADHESIVE ANCHORS AT
24" OC WITH 6 3/4" EMBEDMENT
SIMPSON HETA24 STRAP AT 24" OC
WITH 4" EMBED IN WALL AND
(9) 10d X 1 112" NAILS THROUGH
SHEATHING TO BLOCKING
PLYWOOD ROOF
SHEATHING
PRE-ENGINEERED WOOD
TRUSSES SEE PLAN.
2X4 BLOCKING AT 24" OC
8" CMU BOND BEAM WITH
(2) #5 CONT
CMU WALL
fHESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS ;.
REQUIRED BY FIELD INSPECTORS THAT
AAY•• BE NEUMART I&QRDE.R TO
COPAPLY.dYITH A4 L• t1PPI.ICAE 4 CODES.,,
EJ
CONCRETE SLAB
SEE PLAN _
FILL ALL CELLS BELOW
FINISH FLOOR SOLID WITH
3000 PSI GROUT
CONCRETE FOOTING
SEE PLAN
EL 0'-0"
COORDINATE
WITH W.I.B.
MANUFACTURER
z
0_
w
r
O
w
to
O
a
a
W
w
F
O
r
z
O
H
a
z
0_
O
J
O
3
z
0
w
U
0
0
a
w
z
z
Q
`,``1`lppuuunrtt1"101 ,
:QQ; 1 E
ATLANTIC No 0
-ENGINEERING:
V.
:
6501 Arlington Expressway �O A 11
Building B. Suite 201 •.
Jacksonville, FL 32211 ""�r..��•�
PH: 904.743.4633 FX:904.725.9295 �'�,•• • �•��.w �e•� �p+ �
AES Y317.107 s''pr7F rL w,, 1%
DAVID L WEBB PE 47180
z
z
O
z
0
n
R. Wulbern
Architect PA
AA • 0003433 Ile
(904)329.2510 tcl
robert@wulbemmet
Ul
to
z
z
o
�
Y
U
�
N
a
Uj
w
0
Of
LL
w
�-
Q
N
o
0:
a
N
0
fN
J
C'
o I�
z SO
W
u so
a
t,
OOoa
V '
goldCo.,,
VERTIC L
O
0
4)
J
v
z
N LO
LU
a �0)
r M
O Y
Z� �0
O
LL
aW 0Z
`1 �o w � o
0�2_:U
V v) 0 3
CO
�0WtoU)
moz
l
r
z
0
N
a
Z
in
O
0
U
LU
�i
W
J
0
Z
0
H-
♦—
W
W
S-5