Loading...
HomeMy WebLinkAboutPRODUCT APPROVALrewua ounumy wue vi�miu 1/24/18, 2:30 PM SCANNED BY St. de 1 t { Hot Topics I Submit Smharge I Stats & Fads j FILE COPY > Product or Application Search > Application List > Application Detail FL # 'Application Type Code Version Application Status ,I Comments Archived Product Manufacturer ddress/Phone/Email Authorized Signature I it Technical Representative Address/Phone/Email I Quality Assurance Representative Address/Phone/Email Category Subcategory 11 Compliance Method I Florida Engineer or Architect Name who developed the Evaluation Report Florida License i Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By 1 Certificate of Independence Referenced Standard and Year (of Standard) FL17022-117 Revision 2017 Approved Publications I FBC Staff f BCLS Site Map ! Links Search i 08/18/2017v. date reapply 08/21/17 Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Richard McKuhen flvalidation@yahoo.com Richard McKuhen . 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received LOCKE BOWDEN PE-49704 Keystone Certifications, Inc. 04/22/2024 Zachary R. Priest, P.E. 0 Validation Checklist - Hardcopy Received EL17022 R7 COI FL 17022.1 5 V CRIMP ssr Ddf Standard Year TAS 125 2003 UL1897 2012 https://www.floridabuilding.org/prlpr_app_dti-aspx?param=WGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFesQkCHzEgvOQveeg%3d%3d Page 1 of 4 Florida Ba'�ing Code Online UL 580 i 2006 1/24/18, 2:30 PM ;Equivalence of Product Standards ,Certified By Sections from the Code I Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.t)df Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ss. r.r)df assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (116) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in .HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0,032 ALUM ssr pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturers installation instructions. i 17022.3 3 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24ga ssr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL installation method listed in this report and applicable code seam 24ga ssr. f sections of FBC. Refer to manufacturer's installation {instructions. Created by Independent Third Party: Yes 17022.4 4 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16' wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. -imits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM pp_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d Page 2 of 4 Florida Building Code 0 1124/18, 2:30 PM Approved for use outside HVHZ: 1>_ Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and imitations of use. Install the assembly in compliance with the nstallation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation nstructions. ALUMINUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Created by Independent Third Party: Yes 17022.5 5 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf Created by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation `instructions. �!17022.6 6 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.i2df Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr gdf Created by Independent Third Party: Yes installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.7 7 - "1.5 in. Nail Strip" (R5) 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof 1 panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and Imitations of use. Install the assembly in compliance with the nstallation method listed in this report and applicable code ;ections of FBC. Refer to manufacturer's installation Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strip 26-GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 NakLStriD 26GA ssr.odf Created by Independent Third Party: Yes I17022.8 8 - "EMAX Rib" (R5) 29 gauge steel, lapped roof panel mechanically attached to ' 15/32" plywood or wood deck with exposed fasteners. of Use ved for use in HVHZ: No ved for use outside HVHZ: Yes t Resistant: No n Pressure: +N/A/ Table A Refer to evaluation report for conditions and ms of use. Install the assembly in compliance with the Lion method listed in this report and applicable code s of FBC. Refer to manufacturers installation Installation Instructions FL17022 R7 II FL 177022 8 EMAX Rib ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: -Yes Evaluation Reports FL17022 R7 AE FL 177022.8EMA_X_ Rib ssr odf Created by Independent Third Party: Yes 17022.9 9 - " PBR MAX" (R5) 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. of Use ved for use in HVHZ: No ved for use outside HVHZ: Yes It Resistant: No Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFeSQkCHzEgvOQveeg%3d%3d Page 3 of 4 nuuud owiamg l.00e Vnnne . � I 1/24/18, 2:3o PM Design Pressure: +N/A/ Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AF FL 17022 9 PBR RiB ssr pdf limitations of use. Install the assembly in compliance with the Created by Independent Third Party: Yes !installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Back t�rezt Contact Us :: 2601 Blair Stone 110ad Tallahassee FL 32399 Phone: 850-487-1824 I The State of Florida is an AA/EEO employer. Coovrieht 2007-2013 State of Florida :: Privacy Statement :: Acoessibility Statement • • Refund Stapernent I ,Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section .455 1 275(1), Florida Stabiles, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal iaddress, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dicker . Product Approval Accepts: I ttps://www.floridabuilding' rg/pr/pr app dti.aspx?param=wGEVXQWtDgv2aBQpHpQQerarMZMkUEoR%2bGxHGxFeSQkCHzEgvOQveeg%3d%3d Page 4 of 4 Product d art M, a n u f a C t u r Extreme ME imitations- it - --- ----- - ------, =- -- ------i— - _,' 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are `compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wfjurisdiction is allowed by other registered engineers. 5. Fire. classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter.22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Fasteners N x 1-1/2" Min. or #10 x 1-1/2" Min. per.Tahfe A' for Row 5 V Crimp Roof Pant Spacing and Design Pressures Hex Washer Head Wood Screws i Q �/r Q- I i I � I - I v Deck: -15W or greater PkvvW, or - Wood plank 3V Panel Overlap PanL4 Ike Nominal 12" 1 Nominal 12" O.C. I O.C. Fasten -1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Refer to Table "A" for Spacing Along Panel Length Deck-15/32" or greater Plywood, or - Wood plank