HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online
Page 1 of 4
SCANNED
Business • If d t • ' e $ BY
BCIS Home ! Log In ' User Registration Hot Topics ; Submit Surcharge j Stats & Facts ; Publications FSC Staff BCts Site Map { Links Search
t _ _
t=ry r
Product Approval RECEIVED
USER: Public User FILE
C ® PY
db
JUN 2 22018
Product Approval Menu > Product or Application Search > Aoolication List > Application Detail
FL # FL17022-R7 ST. Lucie County, Permitting
Application Type Revision -
Code Version 2017
Application Status Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
fivalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
✓i Validation Checklist - Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
2012
2006
https://www.floridabuilding. orglprlpr_app_dtl.aspx?param=wGEVXQw-tDgv2aB QpHpQQ... 2/ 16/2018
Florida Building Code Online
Page 2 of 4
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
Summary of Products
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (R6)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions.Install the
FL17022 R7 II FL 17022.2 5 V CRIMP 0,032 ALUM r odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
ALUM ssr.odf
Created by Independent Third Party: Yes
17022.3
3 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16" wide, 24 gauge steel, standing seam
roof panel mechanically attached to 15/32" plywood or wood
deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
FL17022 R7 rI FL 17022.3 1.5 MECHANICAL
seam 24oa ssrodf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
seam 24oa ssr.odf
code sections of FBC. Refer to manufacturer's installation
instructions.
Created by Independent Third Party: Yes
17022.4
4 - "1.5" Mechanical Seam" (RS)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL17022 R7 H FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
ALUMINUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.odf
Created by Independent Third Party: Yes
17022.5
5 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf
Created by Independent Third Party: Yes
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGE VXQw-tDgv2aBQpHpQQ... 2/16/2018
Florida Building Code Online
Page 3 of 4
l
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.6 16 - "1 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.7 17 - "1.5 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.8 18 - "EMAX Rib" (RS)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
1" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Installation Instructions
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUP1 ssr.odf
Created by Independent Third Party: Yes
1.5" rib height, 19" wide, 26 gauge steel, standing seam
roof panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Installation Instructions
FL17022 R7 IT FL 17022.7 1.5 Nail Strio 26GA ssr odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.7 1.5 Nail StriD 26GA ssr odf
Created by Independent Third Party: Yes
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
FL17022 R7 11 FL 177022.8 EMAX Rib ssr odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 177022.8 EMAX Rib ssr odf
Created by Independent Third Party: Yes
17022.9 19 - " PBR MAX" (R5) 26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
Installation Instructions
FL17022 R7 II FL 17022.9 PBR RIB ssr odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.9 PBR RIB ssr.odf
Created by Independent Third Party: Yes
Baek Nett
Contact Us :: 2601 Blair Stone Road. Tallahassee R. 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emails provided may be used for offidal communication with the licensee. However email addresses are public record: If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please dick her.
Product Approval Accepts:
Credit Card
Safe
https://www. floridabuilding. org/pr/Pr_app_dti. aspx?param=wGE V XQwtDgv2aB QpHpQ Q... 2/ 16/2018
I
�:. _... - ^^_Y.1 £ ,�..� ,� •1r.`?`K .. �,.y_...ry. �.^r,,v-.'-"ia a a^;T,s,".vw -. ... ,. .. ..
Product Report Manufacturer: Extreme Metal Fabricators, LLC.
.1 SW Poma
Palm City, FL 34990
Compliant with Florida Building Code 2017 (61' ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 9151 " Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
install Details: Table A_ Allowable Loads I METHOD 1 { METHOD 2
DESIGN PRESSURE* 1 -86 PSF Main field -97.25 PSF Perimeter
FASTENER SPACING ; 6" O.C. I 6" O.C.
1 SEAM ADHESIVE Not required 3/16" continuous bead
(see details
j Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
EQUIVALENCY: UL1897-04 is equivalent to Test Standard ULI897-12. *Design Pressure. margin of safes 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial i9;Vresf11nagy�company manufacturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlle
,
�ny`mP �an.F4pdurer, or distributing products under this
report. ■
® " seal
T E OF <<.�
AL
4
Limitations:
1. Undedayment to be compliance with current Florida Building Code (FBC)2017 60 ed..
2. Minimum slope to be compliant with Florida Building Code 2017 611' ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for'project specific approval by local authorities w1jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report
6. Support framing in compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
Panel Profile
16" O.C.
3/4'
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3116" Bead Bostik 915TM Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1" Min. per Table "A'
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
,4 .
1"
FL 17022.5
1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
-15/32" or greater Plywood, or
- Wood plank
FactanPr
Isometric View
Apply 3/16" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table " A")