Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 4 SCANNED Business • If d t • ' e $ BY BCIS Home ! Log In ' User Registration Hot Topics ; Submit Surcharge j Stats & Facts ; Publications FSC Staff BCts Site Map { Links Search t _ _ t=ry r Product Approval RECEIVED USER: Public User FILE C ® PY db JUN 2 22018 Product Approval Menu > Product or Application Search > Aoolication List > Application Detail FL # FL17022-R7 ST. Lucie County, Permitting Application Type Revision - Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 fivalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. ✓i Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 https://www.floridabuilding. orglprlpr_app_dtl.aspx?param=wGEVXQw-tDgv2aB QpHpQQ... 2/ 16/2018 Florida Building Code Online Page 2 of 4 Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to Created by Independent Third Party: Yes manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions.Install the FL17022 R7 II FL 17022.2 5 V CRIMP 0,032 ALUM r odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. ALUM ssr.odf Created by Independent Third Party: Yes 17022.3 3 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable FL17022 R7 rI FL 17022.3 1.5 MECHANICAL seam 24oa ssrodf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL seam 24oa ssr.odf code sections of FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.4 4 - "1.5" Mechanical Seam" (RS) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 H FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. ALUMINUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Created by Independent Third Party: Yes 17022.5 5 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf Created by Independent Third Party: Yes https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGE VXQw-tDgv2aBQpHpQQ... 2/16/2018 Florida Building Code Online Page 3 of 4 l the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 16 - "1 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.7 17 - "1.5 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 18 - "EMAX Rib" (RS) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUP1 ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 IT FL 17022.7 1.5 Nail Strio 26GA ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail StriD 26GA ssr odf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 11 FL 177022.8 EMAX Rib ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr odf Created by Independent Third Party: Yes 17022.9 19 - " PBR MAX" (R5) 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr.odf Created by Independent Third Party: Yes Baek Nett Contact Us :: 2601 Blair Stone Road. Tallahassee R. 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for offidal communication with the licensee. However email addresses are public record: If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick her. Product Approval Accepts: Credit Card Safe https://www. floridabuilding. org/pr/Pr_app_dti. aspx?param=wGE V XQwtDgv2aB QpHpQ Q... 2/ 16/2018 I �:. _... - ^^_Y.1 £ ,�..� ,� •1r.`?`K .. �,.y_...ry. �.^r,,v-.'-"ia a a^;T,s,".vw -. ... ,. .. .. Product Report Manufacturer: Extreme Metal Fabricators, LLC. .1 SW Poma Palm City, FL 34990 Compliant with Florida Building Code 2017 (61' ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 9151 " Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. install Details: Table A_ Allowable Loads I METHOD 1 { METHOD 2 DESIGN PRESSURE* 1 -86 PSF Main field -97.25 PSF Perimeter FASTENER SPACING ; 6" O.C. I 6" O.C. 1 SEAM ADHESIVE Not required 3/16" continuous bead (see details j Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 EQUIVALENCY: UL1897-04 is equivalent to Test Standard ULI897-12. *Design Pressure. margin of safes 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial i9;Vresf11nagy�company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlle , �ny`mP �an.F4pdurer, or distributing products under this report. ■ ® " seal T E OF <<.� AL 4 Limitations: 1. Undedayment to be compliance with current Florida Building Code (FBC)2017 60 ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 611' ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for'project specific approval by local authorities w1jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report 6. Support framing in compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" Panel Profile 16" O.C. 3/4' Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock For METHOD 2: Apply 3116" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 X 1" Min. per Table "A' Pancake Head Wood Screw (Typical Fastening Pattern Across Width) ,4 . 1" FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details -15/32" or greater Plywood, or - Wood plank FactanPr Isometric View Apply 3/16" Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange (Refer to Table " A")