Loading...
HomeMy WebLinkAboutSITE PLAN 7-27-18w 1 ---------------------------------------------------- — — — — — — — —N IT 05' 21" E i — O! I a Q:a ! N N m I SETBACK i SILT FENCE.:::::: •- \\ r I SEE DETAIL I•. Z i THIS SHEET \` � Ao S 24° 33' _ Q <r, , PORCH ,4 0 W 60.15' — e ,\ y ADDITION g •\ F.F.E. TO MATCH EXISTING Rf 's Iv90 �\ 38;\ \. 08 �� \ W \•\ moo: 1 F.F.E. TO MATCH �I Z i EXISTING 3 ACTUAL .�..:::::.: � 1 S�gACK � -1 REQ D � 1 SACK n't � 1 N 48° 12' 56" W 15.14' el-----•-------•-•----- 252.59' I I I I I 1 I t 1 _._._._._._._._._._. ._._ _ _ _ _ _ _ _ _ __._.-._._.-._._._._._._._._._._._._.6._._.. N 1-10 OS' 21" E 186.21' POST: 2" X 4" P.T. POST OR 2 1/2" MIN. DIAMETER WOOD: STEEL 1.33 LBS/FT MINIMUM FILTER FABRIC: IN CONFORMANCE W/ SECTION S85 FDOT SPEC. 6, MAXIMUM ELEVATION SILT FENCE DETAILS NOT TO SCALE PRINCIPAL POST POSITION: CANTED 20° TOWARD FLOW Q u .--FILTER FABRIC j V..,. !. SECTION SITE PLAN 1/1611 s 1-Ofi AREA CALCULATIONS LIVING AREA 3 1 fo I SOFT NON -LIVING AREA 1 4 8 S SOFT TOTAL UNDER ROOF 5 2 5 0 SOFT TOTAL LOT AREA 3 0 8 0 5 SOFT STRUCTURAL FOOTPRINT 1 '1 . O 4 % LEVEL 2 ALTERATION 2 O 1 1 FLORIDA_ BUILDING CODE 8.0.,1,. GEAlERA1.,_•,...,...,..,u,.,,..,,.-,.,.,.,_____....._.___,,,,,,,,,,,,,,.,...,,, 8,.0.,3...,., BUILDING ELEMENTS AND.. -MATERIALS 8.0 STRUCTURAL..,,..,,..,,..,,.,,._,,.,.,.._.,_-,_,._,._-__.................,..,., 808 5 ELECTRICAL THE LEVEL OF WORK SHALL INCLUDE THE FOLLOWING: FORM t POUR NEW CONCRETE SLAB FRAME t POUR NEW C.M.U. WALLS INSTALL NEW P.T. WOOD POSTS INSTALL NEW ELECTRICAL CIRCUITS INSTALL NEW ELECTRICAL FIXTURES INSTALL PRE-ENGINEERED WOOD TRUSSES AT 24" O/C MAX. JUL P, 7 'I'll ST. Lucie County, parr SCANN L BY St. Lucia "buok (V It U T lu m U- � Ur O N U J IQ W I ij O 2 9 MAY 18 OF FIVE --F ---F --- I I - ----- --- — . I, N I I' I I I ' — I , f 1 I I I I ( I f1 ' II , I , I '-------------- ---- ROOF FRAMING TO REMAIN - - ROOF FRAMING TO BE REMOVED " 1 II II II REMOVE EXISTING DBL II i 2" X 121, WOOD BEAM REMOVE EXISTING SCREEN ENCLOSURE 4- EXISTING WOOD POST TO � BE REMOVED ' I IZ II II I 1°i II ROOF FRAMING REMOVE EXISTING TO BE REMOVED SCREEN ENCLOSURE 1 REMOVE EXISTING PORTION TRIPLE 2" X IV WOOD BEAM KELLY 4 KELLY ARCHITECTS 18 NOT RESPONSIBLE FOR A NECESSARY REPAIR, REPLACEMENT OR RENOVATION TO ANY UNFORSEEN, CONCEALED STRUCTURAL CONDITION EXPOSED DURING THE DEMOLITION PHASE OF A REMODELING PROJECT ANY 4 ALL EXPENSES RELATIVE TO SUCH A SITUATION SHALL BE THE RESPONSIBILITY OF THE OWNER EXISTING TRUSSES PRE-ENGINEERED SCAFFOLDING BEAMS +�— PRE-ENGINEERED SCREW -JACK —> SCAFFOLDING VERIFY SPACING W/ MANUFACTURER FOR ALL PRE-ENGINEERED SCAFFOLDING, BEAMS 4 CROSS -BRACING TRU55 SHOR"'ING DETAIL I11 = II-O" DEMOLITION 1/4" = 11-O" '- --------------------------- \1 I 1 I I --------------- I I I + ' 1 1 I I I I I I \ , e I I I i + I I I , I 1 I 1 I I + I I L I I I I I I I I 1 I I , I e I \ I + 1 I I 1 I I I + I SHORE EXISTING ROOF TRUSSES 4 It ' BEAMS BEFORE BEGINNING ANY I DEMOLITION, SEE DETAIL THIS SHEET I COVERED PORCH + EXISTING - ----- --------------- ------------------------- - -- �-------------- ------------ \J ROOF FRAMING TO REMAIN II I + EXISTING POOL DECK I II • REMOVE 4 REPLACE EXISTING POOL , DECKING W/ NEW I I I I � I POOL \ I EXISTING I I . I i I I.I I II I , I' I I I I : I I I I I + I I I I ' I , I I I, I REMOVE 4 REPLACE EXISTING SCREEN ENCLOSURE W/ NEW , ----------- ........... ....----------- ....... ------ ------ -------------------n PLAN REMOVE 4 REPLACE EXISTING I SCREEN ENCLOSURE W/ NEW ' DOWEL NEW SLAB TO EXISTING W/ 8" LONG •5 BAR DOWELED 4 EPDXIED INTO EACH s 48" O.C. 4" THICK 3,000 P.S.I. MINIMUM FIBERMESH CONCRETE — • o 6"MINIMUM _�__ "_> C • A G C EXISTING SLAB NEW BLAB 6 MIL. VAPOR BARRIER ON 2,500 P.S.I. COMPACTED 4 TERMITE TREATED SOIL SLA5 REPAIR DETAIL 3/4" = 11-O" GREATER THAN 24" DOWEL NEW SLAB TO EXISTING SLAB WITH 1/4" x 3" TAPCONS B 12" O.C. STAGGERED W/ I" MIN. EMBEDMENT INTO EXISTING SLAB 4" THICK 3,000 P.S.I. MINIMUM FIBERMESH CONCRETE — '✓I I" MINIMUM C ' C C -ate' d EXISTING SLAB NEW SLAB Fi MIL. VAPOR BARRIER ON 2,500 P.S.I. COMPACTED 4 TERMITE TREATED SOIL SL415 REPAIR DETAIL 3/411 = 11-011 LESS THAN 24" LEGEND 8" X 8" CONCRETE FILLED CELL W/ I - 05 BAR DOWELED TO FOOTING 4 HOOKED TO BEAM a ALL WINDOWS, DOORS, CORNERS 4 AT 48" O/C MAXIMUM CONCRETE POURED 4 FORMED IN PLACE W/ 2 - +5 BARS DOWELED TO FOOTING 4 HOOKED TO BEAM 16" X 16" CONCRETE FILL CELL W/ 4 - 05 BARS DOWELED TO FOOTING 4 HOOKED TO BEAM FOOTING SCHEDULE MARK SIZE STEEL REMARKS ® 24" WIDE X 14" DEEP 3 - 05 BARS MONOLITHIC © 8" WIDE X 8" DEEP I - •5 BAR MONOLITHIC © 12" WIDE X 8" DEEP 2 - 05 BARS MONOLITHIC O 36" W X 36" W X 121, D 05 BARS ® 8" O/C PAD MONOLITHIC FOUNDATION NOTES BOTTOM OF ALL FOOTERS MUST BE MINIMUM 12" BELOW FINISH GRADE THE OUTER BAR OF ALL EXTERIOR LOAD BEARING FOOTERS SHALL BE CONTINUOUS AROUND CORNERS OR BY BENDING WITH MINIMUM 30" LAP EACH DIRECTION ALL FOOTER BARS SHALL HAVE MINIMUM 3" CONCRETE COVER WHERE THE CONCRETE IS CAST AGAINST THE EARTH OR 1 1/2" WHERE THE CONCRETE IS EXPOSED TO EITHER WEATHER OR THE EARTH ALL DOWEL BARS SHALL HAVE A STANDARD 90 DEGREE HOOK AND BE EMBEDDED 6" INTO FOOTING DOWEL BARS SHALL LAP VERTICAL WALL REINFORCING BARS MINIMUM OF 30" PLEASE NOTIFY THIS OFFICE OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH ANY WORK TYPICAL FOR ALL CONCRETE (3,000 P.S.I. CONCRETE) 4" THICK CONCRETE SLAB W/ 6" X 6" 10/10 W.W.F. OR FIBERMESH OVER VAPOR BARRIER OVER CLEAN, COMPACTED AND TERMITE TREATED SOIL (2,500 P.S.F. SOIL) ,-4,1 , I , 'UU-) I I EXISTING I � I ® I EXISTING FLUSH FOUNDATION I I I I � I : I I Ij____________ _ '_________ _ ____ __ 5 r r. -,• rr NEW DOURI Nw SLAB INTO EXISTING, SEE FOUNDATION I DETAIL THIS SHEET A I I -- 10 'v ' I ® I CV ' I I n11 I,1 14'-6" I II I •5 BARS AT S" O/C EACH WAY 14'-6" FOUNDATION 1/411 = 11-011 lygrc±_I EXISTING �11- I I I L I I I e 1 I + 1 I . i I I I EXISTING ~• POOL DECK �. REMOVE 4 REPLACE �. EXISTING POOL DECKING W/ NEW I POOL + EXISTING I OL DECK PROPOSED POOL DECK � I , I I , I EXISTING I PROPOSED POOL n POOL DECK I DECK I O O A A , j 41'-1 ST. LUCIE COLIN ING D ION REVIEWED FOR C ANC REVIEWED Y DATE _ PLANS A PER US KEPT ON Jn9- SITE OR NO INS CTION(S) WILL BE MADE f=LAN_ FILE COPY i••u 0 t 1 V O LL 7 �`"' z U tu lu z (y.Q II W z T t�U z z K1 REI/ISIONb 2 5 JUL 1811 2 9 MAY 1 8 18112 2 OF FIVE —---——SIDESETSACK ———— \ — — —�— —\— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ----------------C:I[ ID 1 , I , I , 1 II i i II 1 / I r 1 , I r 1 r r r r , r ; 1 II \ II I II ----- ---- 1 I EXISTING 150 AMP ELECTRICAL PANEL W/ 12 SPARES — NEW i \ " .u. j (MATCH 36SCREEN C \ i EXh v EXISTING 3z" FLUSH suu -Or COVERED \ j COVERED PORCH -- STONE B EXISTING VENEER \ C \ J •.....�. .�.�... � .—. —.— WALL TV o v I \ ------------- - - ® --- ------------ ---------------- ---- - �� EXISTING WOOD POSTS \ I FIRELESS GAB % V)kULTED CEILING , . / 1 \ \ I FIREPLACE, / r \ NO CHIMNEY / OUTDOOR TI , i I \r LIVI \ / 12'-3" AT PEAk\ , I r V 6" X 6" P.T✓GIOOD \ N ry/POST 60E'D XOUT \ , TO B" 6" (TO 12 12 \ MATCA Dd$T$iG) \ \ 14 \ 'a G - R EXISTING - - - 3�`J`\ \ 4- _ _ _1-- I _ POOL DECK \ --N9U SCREEN 14."'------------ -------------------- 4 REMOVE 4 REPLACE ; ENCLOSURE EXISTING POOL 1 \\ DECKING W/ NEW I r � r r \ A I \ r 1 ` 4 � FweH \ \ POOL AREA CALCULATIONS EXISTING UNDER ROOF 5 O 8 3 SOFT LIVING AREA NON -LIVING AREA 3 1 ro 1 1 3 2 2 SOFT SOFT ADDITION COVERED PORCH I ro'7 SOFT PROPOSED UNDER ROOF 5 2 5 O SOFT LIVING AREA NON -LIVING AREA 3 1 ro 1 1 4 8 9:SQFT SOFT LEGEND EXISTING 2" X ro" FRAME WALL CO EXISTING 2" X 4" FRAME WALL Y.L� l CJ PROPOSED 8" C.M,U. WALL PROPOSED 2" X roll FRAME WALL C� PROPOSED 2" X 4" FRAME WALL 8" X 8" CONCRETE FILLED CELL W/ 1 - 05 BAR DOWELED TO FOOTING 4 HOOKED TO SEAM IN ALL WINDOWS, DOORS, CORNERS 4 AT 45" O/C MAXIMUM FLOOR 114" = 1'-O" \ EXISTING 1 \ NEW EXISt_I� 1 ' NMJ 1 I 1 i j 1 I jj p I 1 � 1 1 i (1 SCREEN ENc ENCLOSURE PLAN PROPOSED POOL DECK r I PROPOSED POOL DECK / - / / NEW M/W— \ \ II / IIv 1\ / 1 BREAKFAST KITCHEN I EXISTING ° EXISTING \ ..........................i NEW IGAS RANGE W/ / \ EXH, FAN IN HOOD ONE STORY RESIDENCE EXISTING \ / ----------------------- --------------------------------- / / / III / I / L — I 1 PROPOSED EXISTING POOL DECK POOL DECK E I � i NEVI SCREEN REMOVE i REPLACE EXISTING ENCLOSURE SCREEN ENCLOSURE W1 NEW - --------._.. 26'-0" ) L 12'-2" 38'-2" -------------- ------ ---- ------------------------- ......, 1 � 1 ' I I 1 , 1 r I � 1 U 1 A co c%4 O ( E 4 V [2 (y LL Q Q U —! UV! w LU VJ uV� Uu- 0 z Lu Lu J z uj r� Q Q 'Q � Q r.� 1X m O z 1I1 V fV REVISIONS 2 5 JUL 1 8 2 9 MAY 18 18 112 OF FIVE