HomeMy WebLinkAboutICC-ES REPORTSCANNED
BY
DIVISION: 0600 00—WOOD, PLASTICS AND COMPOSITES
SECTION: 0616 00—SHEATHING
DIVISION: 07 00 00--THERMAL AND MOISTURE PROTECTION
SECTION: 07 25 00---WATER-RESISTIVE BARRIERS/WEATHER BARRIERS
SECTION: 07 27 00—AIR BARRIERS
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
ONE RESOURCE SQUARE
10925 DAVID TAYLOR DRIVE, SUITE 300
CHARLOTTE, NORTH CAROLINA 28262
EVALUATION SUBJECT:
ZIP SYSTEM" WALL SHEATHING
I
1CC 1CC ICC
C PrVIG LISTED
Look for the trusted marks of Conformity?
"2014 Recipient of Prestigious Western States Seismic Policy Council
(WSSPQ Award in Excellence"
A Subsidiary of
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a
recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to anv finding or other matter in this report, or as to any product covered by the report. a« rcv+
Copyright D 2016 ICC Evaluation Service, LLC. All rights resented. File COPY
iCC-ES Evaluation Report ESR-1474
Reissued October 2015
This report is subject to renevva/ October 2018.
www.icc-es.orq 1 (800) 423-6587 1 (582) 699.0543 A Subsidiary of the International Code Council`
DIVISION: 06 00 00—WOOD, PLASTICS AND
COMPOSITES
Section: 06 16 00--Sheathing
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Sectiom.07 25 00—Water-resistive BarriersfWeather
Barriers
Section: 07 27 00--Air Barriers
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
ONE RESOURCE SQUARE
10925 DAVID TAYLOR DRIVE, SUITE 300
CHARLOTTE, NORTH CAROLINA 28262
(800) 933-9220
viww.huberwood.com
EVALUATION SUBJECT:
ZIP SYSTEM` WALL SHEATHING
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2015, 2012 and 2009 International Building Coda' (IBC)
2015, 2012 and 2009 intemational Residential Code
(IRC)
11 2015, 2012 and 2009 Intemational Energy Conservation
Code® (IECC)
Properties evaluated:
m Weather resistance
r Air leakage
2.0 USES
ZIP System° Wall Sheathing panels are used as
combination wall sheathing, air barrier, and water -resistive
barrier. This report recognizes the use of ZIP System®
Sheathing, when installed with ZIP SystemT'•' flexible
flashing seam tape, in walls of Type V construction (IBC)
and dwellings under the IRC, and as an alternate to the
water -resistive barrier required in Chapter 14 of the IBC
and Chapter 7 of the IRC, and to the air barrier required by
Sections R402.4 and 0402.5.1 of the 2015 IECC (Sections
R402.4 and C402.4.1 of the 2012 IECC; Sections 402.4.1
and 502.4.3 of the 2009 IECC).
3.0 DESCRIPTION
3.1 Sheathing Panel:
The ZIP SystemiD Wall Sheathing panel is an OSB wood
structural panel having a laminated exterior facer. The
Exposure 1 OSB complies with US DOC PS 2 for wood
structural panels. The exterior facer is a medium -density,
phenolic -impregnated, polymer -modified shee`. material
qualifying as a Grade D watar-resistive barrier (required by
Section 2510.6 of the 2012 and 2009 IBC). The'panels are
nominally 4 feet wide by 8, 9, 10, 11 or 12 feet long and
have a square -finished -edge or machined -edge profile.
LVnen tested in accordance with ASTM E96 (water
method), the polymer -modified sheet overlay has a
minimum vapor permeance of 12 pears [68.6 X
10-" kg/(Pa-s-m2)1. Equivalent Water Vapor Transmission
rate (WVf) of the polymer -modified sheet overlay is
83.4 g/(24h-m2) when tested at 73.4'F (23'C).
The water -resistive barrier and air barrier properties of
the ZIP System Wall Sheathing Panels are not affected
when the panels are manufactured to comply as facing
materials for SIPS in accordance with Section R310.3.2
and Table R610.3.2 of the 2015 IRC (Section R613.3.2
and Table R613.3.2 of the 2012 and 2009 IRC).
3.2 Seam Tape:
The ZIP SystemTm seam tape is a self -adhering membrane
tape consisting of acrylic adhesive laminated to a
polyolefin backing. The to?e is 0.012 inch (0.30 mm) thick
with a minimum width of 3 14 inches (95.2 mm), and comes
in rolls of various lengths.
4.0 INSTALLATION
4.1 General:
Installation of ZIP Systems Wall Sheathing panels must
comply with the applicable code, this report and the
manufacturer's published installation instructions. The
manufacturer's published installation instructions must be
available at the jobsite during installation.
4.2 Application:
4.2.1 General: The ZIP System"' Wall Sheathing panels
must be attached to wall framing in accordance with the
applicable code for wood structural panels, and in
compliance with their panel span rating. The panels must
be installed with the polymer -modified sheet overlay
facing the exterior. In accordance with the manufacturer's
published installation instructions, it is recommended that
the square edges of the panels be installed with a gap
!CC -ES Evahatian Resorts are not to be construed as representing aestheucs or any other anribuies nor spec fcolty addressed, nor are they io be construed
as an endorsement of the sunjac: of the report or a reeommendanon for as use There /.r no aarranry by rC'C Evaluauan Service, LLC, express or implied, as
to anw finding or orher maser in this report, or as to any product covered fv the report, m
Copyright 0 2016 fCC Evaluator. service, LLC. All rights reserved.
,I)
Page I of 6
ESR-1474 1 .Most Widely Accepted and Trusted Page 2 of 6
between adjacent .panels and between panels and
dissimilar materials. All ZIP System® Wall Sheathing panel
seams must be sufficiently sealed with ZIP System seam
tape. All overlay surfaces must be dry and free of sawdust
and dirt prior to application of the ZIP System seam tape.
The ZIP SystemThl seam tape must extend a minimum of
1 inch (25.4 mm) past the panel edge T-joint intersections
and must be centered within 1/2 inch (12.7 mm) over the
middle of panel seams_ The tape must be pressed firmly to
adhere to the surfaces, and seal the seams. Wrinkles in the
ZIP System- seam tape are acceptable unless they
create a leak path to the panel seam.
4.2.2 Flashing: Flashing complying with the applicable
code must be installed at the perimeter of door and
window assemblies, penetrations and terminations of
exterior wall assemblies, exterior wall intersections with
roofs, chimneys, porches, decks, balconies, and similar
projections, and at built-in gutters and similar locations
where moisture could enter the wall. An adhesive -backed
flashing tape recognized 'n a current ICC-ES evaluation
repo„ must be installed to Baal a'I ZIP System' b^lali
Sheathing dashing joints' Penetration sterns must be
sealed to the paneis. The adhesl,,s-backed flashing tape
must comply with the ICC-ES Acceptance Criteria for
Flexible Flashing Materials (AC148) and must be installed
in accordance ;with the manufacturer's published
installation instructions. See Figures 1 through 7 of this
report for typical dashing, water -resistive barrier and air
barrier assembly installation, details.
4.2.3 Air Barrier Assembly: ZIP System Wall
Sheathing fastened to maximum 24-inch-on-center
(610 mm), wood veall framing, using minimum 6d nails
spaced at 6 inches (152 mm) around panel edges and at
12 inches (305 mm) in the field, leaving a 1/9-inch
(3.18 mm) gap between panels, forms an air barrier
assembly when the gaps between panels and the
perimeter of penetrations are sealed with ZIP SystemT"
seam tape as required by Section 4.2.1. The assembly has
demonstrated a maximum air leakage of 0.0072 cfm/f-
[0.037 L/(s•m2)] infiltration and 0.0023 cf T-,Ie
(0.012 U(s"m2)] exfiltration at a pressure differential of
1.57 psf (75 Pa) when tested in accordance with
ASTN-1 E2357.
5.0 CONDITIONS OF USE
The ZIP System® Wall Sheathing panel and tape system
described in this report complies with, or is a suitable
alternative to what is specified in, those codes listed in
Section 1.0 of this report, subject to the following
conditions:
6.1 This evaluation report and the manufacturer's
published installation instructions, when required by
the code official, must be submitted at the time of
permit application.
5.2 The ZIP System Wail Sheathing panels must be
manufactured, identified and installed in accordance
with this report and the ma.nufacturer's published
installation instructions. In the event of a conflict
befiveen the instructions and this report, this report
must govern.
5.3 The ZIP System® Wall Sheathing panels must be
covered with a code -complying exterior wall covering,
or one that is recognized in a current ICC-ES
evaluation report.
5A The OSB sheathing most comply with US DOC PS-2,
5.5 Fire-resistar'ce-ratsd co^S°nJut'on IS ojtside the
Scope or this repo, t.
6.0 EVIDENCE SUBMITTED
6.1 Data in accordance hith the ]CC -ES Acceptance
Criteria for Water -resistive file nbranes Factory -
bonded to VAlcod-based Structurai Sheathing, Used as
Water -resistive Barriers (AC310), dated May 2008
(editorially revised August 2015).
6.2 Air leakage data !n accordance with AS-Dil E2357.
7.0 IDENTIFICATION
Each ZIP System Wail Sheathing panel described in this
report must bear a label that includes the manufacturer's
name (Huber Engineered Woods LLC), the product name,
nominal panel thickness, the evaluation report number
(ESP.-1474), and the words "Mill 229, Crysta! Hill, Virginia";
'Mill 228, Easton, Maine"; "Mill 227, Commerce, Georgia";
or'Miil 290, Broken Bow, Oklahoma." The OSB sheathing
must also bear a label demonstrating compliance with
US DOC PS 2 from an approved inspection agency. The
ZIP SystemTh' seam tape roll must be labeled with the
ZIP System logo and the evaluation report number
ESR-1474 (see Figure 8).
ESR-1474 Most Widely Accepted and Trusted Page 3 of 6
DUTSA INME
1NFL-0W FAL � f
ACHUPE-SA'Ds
FL&.':,,; 7An
ZuDN FRAUI!w-
SILL SECTION
M" EP
c►uuixc
Kcawolom
BY FLU90 D
NJNTA 'FU
HEADER SECTION
FIGURE I —TYPICAL CROSS SECTIONS OF FLANGED WINDOW'
ESR-1474 1 Most Widely Accepted and Trusted Page 4 of 6
SILL SECTION HEADER SECTION
21P SYSTEM'—,
-SACKED W'AII SHEATH Y,
A�HEa'�E
/ RASHItIG fAH
OUTSIDE / �CAUUSIpC
I /
` ROUCH OPENING
/
INSIDE
iCtV-FRES'.dJRE
P00U:ET4AIIE FOAM
JAMB SECTION
FIGURE 2—TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW
ESR-1474 I Most Widely Accepted and Trusted Page 5 of 6
ZIP SYSTEMTM
YSTEMT"'
WALL SHEATHING
L SHEATHING
WALL FRAMING
RAMING
tADrESIVE-BACKED
ADHESIVE -BACKED FLASHING TAPE
PLASHNG TAPE
FLASHING FA5iENEP,L
FLASHSp:G
COUNTERFLASHING
FLASHING FASTENER
BASE FLASHING
%
ADHESIVE -SACKED FLASHING TAPE
r- FLASHING FASTENER
AI)FESM-6AGKEDFLASHINGTAFE
ROOF UNCERLAYMEN7 (r1T)
/ROOF UNDERLJL`1` fM FELT)
1 RODF SF4Th1NG
/ r- ROOF SHEATHING
ROOF JOIST
FIGURE 3-ROOF-WALL INTERSECTION (OPTION 1)
i!"-=1�1f 11 =fr= Itrsa
`-'ll— f'•
r� q
FIGURE 5--TYPICAL WALL -SILL INTERSECTION
AND FLASHING DETAILS FOR BRICK SIDING
ROOF JOIST
FIGURE 4-ROOF-WALL INTERSECTION (OPTION 2)
=a
sY��•
• • � !•rr►re it
.
a1C u�Tu�
n=t �IL�t
_ - - -- _. a1Gtv.R
FIGURE 6-TYPICAL WALL -SILL INTERSEEC71ON
AND FLASHING DETAILS FOR LAPPED SIDING
ESR-1474 1 Most Widely Accepted and Trusted Page 6 of 6
Adhesive -Backed
Flashilr.Q Tape
FIGURE 7—INSTALLATION AT PENETRATION OPENING (kON-FIRE-RESISTANCE RATED)
FIGURE 8—LABELING FOR THE ZIP SYSTEM SEAM TAPE ROLL
IMES Evaluation Report ESR-1474 FBC Supplement
Reissued October 2016
This report is subject to renewal October 2018.
waww,1cc-e1.or2 ( (800) 423-6587 j j662) 699-0543 A Subsidiary of the International Code Council'
DIVISION: 06 00 00—WOOO, PLASTICS AND COMPOSITES
Section: 06 16 00—Sheathing
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION
Section: 07 25 00—Water-Resistive BarrieraM/eather Barriers
Section: 07 27 00--Air Barriers
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
ONE RESOURCE SQUARE
10026 DAVID TAYLOR DRIVE, SUITE 300
CHARLOTTE, NORTH CAROLINA 28262
j800) 933.9220
www.hubenvood.com
EVALUATION SUBJECT:
ZIP SYSTEM' )rVALL SHEATHING
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose o,' this evaluation report supplement is to indicate that ZIP System' Wall Sheathing panels, recognized in
ICC-ES master evaluation report ESR-1474, have also been evaluated for compliance with the codes noted below.
Applicable code editions:
st 20,14 Florida Building Code --Building
* 2014 Florida Building Code --Residential
2.0 CONCLUSIONS
The ZIP System® Wall Sheathing panels, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474,
comply with the 2014 Florida Building Code --Building and the 2014 Florida Building Code —Residential, provided the design
and installation are in accordance with the International Building Codeo provisions noted in the master report.
Use of the ZIP System® Wall Sheathing panels for compliance with the High -Velocity Hurricane Zone provisions of the
2014 Florida Building Code —Building and the 2014 Florida Building Code —Residential has not been evaluated, and is
outside the scope of this evaluation report.
For products falling under Florida Rule gN-3, verification that the report holder's quality -assurance program is audited by a
quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the
responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by
the Commission).
This supplement expires concurrently with the master report, reissued October 2016.
1CC-ES Einivaiion Pepor:s are not to be epnstrued at representing aestheires or any other oartbutes not.specificaPy addressed, nor are they to be construed
as an endors.re,^t of the sub,,ect of the report or a recommendatmnlor its :csx. There is no Haman h), ICC Eraluatian Sereice, LLC. express or implied, as
to ayflyndit g or other metier in this report, or as to any product covered by the report.
GopydghtC 20i51CC Evalua?ton Service, LLC. All eights resented. Page 1 of 1
ICC-ES Environmental Report VAR-1012
Reissued September 2095
This report is subject to renewal September 2017.
www.icc-es.org/ep j (800) 423-6687 i (562) 699-0543 A Subsidiary of the International Cade Council
DIVISION: 06 DO 00--WOOD, PLASTICS AND
COMPOSITES
Section: 06 12 DO --Structural Panels
Section: 06 16 DO —Sheathing
DIVISION: 07 DO 00®—THERMAL AND MOISTURE
PROTECTION
Section: 07 21 00---7hernial insulation
Section: 07 25 00---Water-Resistive 8arriersilvIleather
Barriers
Section: 07 27 00--Air Barriers
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
10925 DAVID TAYLOR DRIVE
CHARLOTTE. NORTH CAROLINA 28262
(800)933-9220
vr,?Av.huberviood.com
EVALUATION SUBJECT:
ADVANTECHa' (AT -SERIES) SHEATHING SPAN;
ADVAINTECH' (AT -SERIES) FLOOR SPAN; ZIP SYSTEM'
ROOF SHEATHING; ZIP SYSTEM" WALL SHEATHING;
ZIP SYSTEM" R-SHEATHING (INSULATiNG SHEATHING)
1.0 EVALUATION SCOPE
Compliance with the following evaluation criteria:
• ICC-ES Environmental Criteria for Determination of Bio-
based Material Content (EC 1D2), dated March 2012.
• ICC-ES Evaluation Guideline for Determination of
Source of Recovery, Extraction, Harvest and
Manufacture for Materials or Products (EC114), dated
March 2012
• ]CC -ES Environmental Criteria for Determination of
Formaldehyde Emissions of Composite Wood and
Engineered Wood Products (EC108), dated March
2012.
• ]CC -ES Environmental Criteria for Determination of
Certified Wood and Certified Wood Content in Products
(EC109), dated itilarch 2012,
Compliance eligibility with the applicable sections of
the following green building rating systems, standards
and codes:
• 2012 International Green Construction Code (IgCC)
(see Table 2 for details)
• 2013 California Green Building Standards Code
(CALGreen), Title 24, Part 11 (see Table 3 for details)
• National Green Building Standard (ICC 700-2008)
(see Table 4 for details)
• National Green Building Standard (iCC 700-2012)
(see Table 5 for details)
• LEED for Homes 2008 (see Table 6 for details)
• LEED v4 for Homes Design and Construc-tion (see
Table 7 for detalis)
LEED 2009 for New Construction and :Major
Renovation,- (see Table 8 for details) LEED 2009 for
Schools New Construction and Maio, Renovations (see
Table 9 for details)
• LEED v4 for Building Design and Construction (BD+C)
(See Table 10 for details)
ANSUGBI 0'-2010 — Green Building Assessment
Protocol for Commercial Buildings (see Table 1 i for
details)
2.0 USES
AdvanTech' (AT -Series) Sheathinqi Span, AdvanTecha
(AT -Series) Floor Span, ZIP System Roof Sheathing and
ZIP System Wall Sheathing are used for a variety of
interior and exterior framing and sheathing applications.
ZIP System' P,-Sheathing panels are used as
combination wall sheathing and continuous insulation in
conventional wocd-framed wall construction.
3.0 DESCRIPTION
AdvanTecho (AT -Series) Sheathing Span and AdvanTech'e
(AT -Series) Floor Span wood structural panels are
Exposure 1 oriented strand board (OSB) panels
manufactured with strands from a single wood species or a
combination of wood species blended with an exterior -type
adhesive system to comply with U.S. DOC PS-2 and the
applicable ICC-ES report as indicated in Table 1.
ZIP Systema Roof Sheathing and ZIP System® Wall
Sheathing wood structural panels are OSB panels with
laminated, resin -impregnated, polymer -modified sheet
material manufactured to comply with U.S. DOC PS-2 and
the applicable ]CC -ES reports as indicated in Table 1. The
panels are installed with ZIP System® self -adhering
membrane tape. The tape is outside the scope of this
evaluation report.
ZIP System0 R-Sheathing is an insulated sheathing
made by combining 7/16-inch-thick ZIP Systeme Wall
iCC-ES Verif-icalion ofAllribules Reports are issued. under the rCC-ES VAR Environmental Program. There mparis are nor to be carutrired.ar repre..-eningaeslhencs or any other
cnrrbarar not sperjcally addressed, nor am fhey to he cursrnted as an endonemeor of the subject of the moor, or a mcnmmendanan for its rise There is no fvarranty by 10f FJ
Evahtaifun Serviec, LLC, apress ar imp&d, as to anyfrmling or other mailer in ihis report, ar ar la wry product covered by the report.
Copyright 0 2016 [CC Evaluation Service, LLC. All eghts reserved, Page 1 of 6
VAR-1.012 j Most 1417delyAccepted and Trusted Page 2 of 6
Sheathing as described in ESR-1474 with a layer of
maximum 1-inch-thick (25.4 mm) rigid foam plastic
insulation laminated to the interior face with PVA adhesive.
Refer to ESR-3373 for additional product description.
4.0 CONDITIONS
4.1 Code Compliance:
AdvanTecho (AT -Series) Sheathing Span, AdvanTecho
(AT -Series) Floor Span, ZIP System Roof Sheathing, ZIP
Systemo Wall Sheathing and ZIP System' R-Sheathing
have been evaluated for compliance ^Kith the requirements
of the International Codes as listed in Table 1 of this report.
4.2 Green Rating Systems, Standards and Code
Eligibility:
The information presented. in Tables 2 through 11 of this
report provides a matrix of areas of evaluation and
corresponding limitations andlor additional project -specific
requirements, and offer benefit to individuals who are
assessing aiig;oility for credits or points.
6.2 ICC-ES EC114. [Evaluation applies to IgCC Section
505.2.5; CALGreen Section A5.405.1; iCC 700-2008
Section 608.1; ICC 700-2012 Sections 609.1.,
11.609.1 & 12.1(A).609.1; LEED Homes MR 2.2(c);
LEED v4 Homes MRc3; LEED NC MR 5; LEED
Schools MR 5; LEED v4 SD+C MRc3; ANSi1GB1 01-
2010 Section 10.1.4.13.
5.3 ICC-ES EC108 [Evaluation applies to IgCC Section
806.1; ICC 700-2008 Section 901.4(6); ICC 700-2012
Sections 901.4(6) & 11.901.4(6); LEED NC EQ 4.4;
LEED Schools EQ 4.4; LEED v4 BD+C EQc21.
5.4 ICC-ES EC109 [Evaluation applies to ICC 700-2008
Section 606.2; ICC 700-2012 Sections 606.2(2),
11.606.2(2) & 12.1(A).606.2; ANSIlG81 01-2010
Section 10.3.2.1).
5.5 Documentation establishing and documenting all
major sources of primary manufacturing energy
[Evaluation applies to iCC 700-2008 Section 506.3;
ICC 700-2012 Sections 606.3 & 11.606131.
The fnal interpretation of the specific requirements of the 5,6 ICC-ES F_.SR-1474 documenting that ZIP System Viail
respective green building rating system, standard andlor Sheathing is equivalent to a code -prescribed water -
code rests with the developer of that specific rating system resistive barrier [Evaluation applies to CALGreen
or standard or the Authority Having Jurisdlct;on, as Section 5.407.1; ICC 700-2008 Section 602 9; ICC
applicable. 700-2012 Section 602.1.8].,
Compliance with items noted as "Verified Attribute" is
subject to any conditions noted in the tables. Decisions on
compliance with those items noted as "Eiigible for Points'
in Tables 2 through 11 rests with the user of this report,
and those items are subject to the conditions noted. The
user is advised of the project -specific provisions that may
be contingent upon meeting specific conditions, and the
verification of those conditions is outside the scope of this
report. Rating systems or standards often provide
supplemental information as guidance.
5.0 BASIS OF EVALUATION
The information in this report, 'including the "Verified
Attribute," is based upon the following supporting
documentation:
5.1 ICC-ES EC102 [Evaluation applies to IgCC Section
505.2.4; CALGreen Sections A4.405.4 & A5.405.2;
ICC 700-2008 Section 606.1(2); ICC 700-2012
Sections 606.1, 11.606.1 & 12.1(A).606.1; ANSIIGBI
01-2010 Section 1.0,1.2.2).
6.7 Refer to ICC-ES ESR-1474 for evaluation of the ZIP
System Wall Sheathing as an air barrier assembly
[Evaluation applies to IgCC Section 605.1.2.1.1; ICC
700-2008 Section 703.2.1; ICC 700-2012 Sections
701.4.3.2, 11.701.4.3.2 & 12A.701.4.3.1; LEAD
Hornes EA 3, LEED v4 Homes EAc7j.
6.0 IDENTIFICATION
AdvanTecho (AT -Series) Sheathing_ Span, AdvanTech®
(AT -Series) Floor Span, ZIP System Roof Sheathing, ZiP
System® Wall Sheathing and ZIP Systems R-Sheathing
products are identified with a stamp noting the
manufacturer's name (Huber Engineered Woods, LLC) and
address, the product name the manufacturing Iodation, the
iCC-ES evaluation report number (if applicable), and the
name or logo of the inspection or grading agency. The
report subjects are also identified on the product and/or
packaging with the VAR Environmental Report number
(VAR-1012) and the ICC-ES SAVE Mark, as applicable.
TABLE 1—REFERENCE STANDARD OR EVALUATION REPORT NUMBER
FOR HUBER ENGINEERED WOODS LLC PRODUCTS
PRODUCT
REPORT NUMBER]
REFERENCE STANDARD
Advan T echo (AT -Series) Sheathing Span
AdvanTech® (AT -Series) Floor Span
E R-17$
�
ZIP Systems Roof Sheathing
ESR-1473 & ESR-2227
ZIP System° Wall Sheathing
ESR-1474 & ESR-2227
ZIP System R-Sheathing
E R- 73
VAR-1012 I hlostl,1.4delyAccectodand Trlisted Pago 3 cf 6
TABLES 2 THROUGH 11
Inters!
p—, f
ZT I
0"
Wdl
P—!r;
5
S-eatKrgR,-tm
ng
TABLE 2—SUMMARY OF AREAS OF ELEGIBILITYYIT4 2012 INTERNATIONAL GREEN CONSTRUCTION CODE
7 SOS 24
D.Wd pmdl�
WA
as
Os
P,w- !,l 7e pee ert4 m-. a 5wml,
—!" h�,W.J. e."A" 1; d L th" 5co "Y' law -I, xly
�A
Pi. �l 41 ,e!Lded kll—.!, l'—wr.ed -Y ".;, a-..-
c
Z)
0
l— .-aa cr.,eta—ma me
t., -w v rap of 0 25, & wWtc rr'.
—=—ES -low
ESR-1474
%Mimi
Pan ..mpcj 'tAUS Doc PS 2 (See Tablet cltpj lep.1
lend 4� me.nx hem.=`ie.chyco err�ja'S. et!trg
TABLE 3—SUMMARY OF AREAS OF ELEGIBILITY WITH 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE
M *.5 1
n.-.,
-Vwtjf-� Pw.e,s eat.,!&c,
fi—�,
lcz�d--. wc 'wes "I u,',,
0
0
c� 4
AZ40151
j3w--Aiei vwa%,
—
--e
lki 405 11 1
by CaVe— a0d.v C—rruab.,
WIN
M-A
.17A
-VA
FVA
5 4071
—el*e
0
A 504 5
e. . aptly to %, —Poses — rldLrA defm'.;.,e
i5A 4 5
TABLE 4—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD (ICC 700-20031
6C2 9
barrier
'AaMatay
Pw types d ticbwed are —d, .0 1.1
T. a.. 5 Xilt, PMdubi =1 X at i..t Met It. —truil.—teilad —t ANE
V.6 1(2)
—M. buld,�V
6
..ql.bi.basedp,-dua.1.1%0,.Ie.Wcast .^u blr Used 1v3XZt,.,,
—t!..
—'Fable fer -rester ma., 0 51.4
- WJIed —W-tased pr3d.14 .,e,.,ed I.,
T. ear. 3 pirm . MM 0-r%VM Y—a prv:Lc:.—t a�e. be ".-d a i-
6C,12(1)
wchaial—t,
3
�,s
dement'
9
0
Of
-2(2)
TE s r4ed -mod-based prod,.'cle ire use for
70 cam 4 pwm I momd artfied —i productmw e� be used as 3 n,ap
we
=j., femme d Se Su ouch as .1 walls,
4
f4mertool 1
M ateo. t'a
b.,Wr,u ware, —ufwv. m .
2
the
6M3
33%.1 pw..qj p,=M;7j
.m. 5 P,1,. produce ,w te usec f., at 1—t 3 ft W ae
dewedIm. —bl I
8.
mas
WVV, 2;4-4m way be tamed w�� Leea lw� each eenpweeL
seice,. or M—Na Vw �tm.
I
Nae Fm". a.lootcd Me, Tabe 11
VAR4012 i Mast',W; e / Acceated and Trjsted Page 4 of S
TABLES 2 THROUGH 11 (Cantinuedl
SaCkn
ZIP Sys3m LPspt.-
Fu 4Ehiu I A111.17 ch advWtTerl: 1+ 1;P SYnsn
Num'>sr
St>'Jcr. intan!
?cln� i Caxiticna cf W. b G+:z:y SM7.Wi t; Fiaorinq 1 — -I' RShs.7:r.0
Stnaditrq ShaahtNJ
TABLE "UMNARY OF AREAS OF ELEGIMILITY WITH THE NATIONAL GREEN BUILDING STANDARD (ICC 700-2008) (Ccnllnu2d)
S]dl
i.".Cis smatadnb 2 aeh
I ei^12 .ro ❑ my bGd praC'eCn are alg ro!m p2Y!u ,;rGw eu urasv et
O O
O
D
__"
_ 0
a'i a7. w•r : 503 t. (505)-1 Of W, st^.
I
i^nJ,7.nn d {
to IaJcn sta ry niro�s-1na mars Safh a..ta:m'ay.^y,
i ✓I ae
i
`
a a'. 31a:ap
s
O
U
_
j
! ^).:lh'.o.pi:Y'rcrit'cauan.7erfc'mec 7 um
7�
-'�
_ _—I
J
s'r.•crxal Frfm: cyst r. i,•i1-,•sn'r,: m_c-7
�
'.:-thhg E. r xcPst..caaasI
.0!:?'1
Z O58 wed Jo, Sm;, vatt c� ;'rr:xl lheet`m,
mgiw—
a:a
rInaiG�Ola!mPS r.'Isn1:a�t'a1.^m.QaMf3tl:eeilrl'aInJdL
9�JT`ealtlCk.�
To mro:'sa a �•irunum of ASK et CE :r yY'eeuc;rt T,ro'6e'vw-1" ;f
F'.ux: sx.'Ixa.
f I •
f
t
f
f
7
Ld!e
!e{Lr':are ]f
'
ioy—di ard'ap.— I tcISDI
;a-.Jlc1
Ne:,.etnrx,g prdu:3,�., irielude n�:v�aral
a
IAmmm'm 005K of prdttl In UIe R�tk"n, am SIa Idc11.11W W,bs
� •
D
•
f
B1
wool hamfr�r
�
;ar:Cuds.
TABLE 6—SUMMARY OF AREAS OF ELEG{H{LITY WITH THE NATIONAL GREEN BUILDING STANDARD (ICC 700 2012)
5C21 ]
'lhCu-ra:.sGre bam-r
hlanc:tary
watm feiaMa ba:ner atMJarc ata,e pan sy� m x'ir1 eslerbr 4ere<r
j
.rys
`1
vdr.
..•
a
a
EC617)
7aa.ypcn of1111-1 matry aM .a 1, 03, 1111
To aama-M pat adu ..t to I—t 1Ka; the anstnr_tcr. nata al co:t Ah
t
It YS;b)
mcm Man lW nf!P�r,xaMs'xajed+l'. �!IC�nC
6
anxher 5ec..al Fmdxz a:l4 of .na 'd cv srs Yusr�Ir'];.or.�et!
•
B�4
+l
O°
1'2.tUS161MI
matertaleast
aYR tleWo'.mii an a:%
50d.2(?)
7»o a wsx wax elud fraay.� a: a LSM n'
I
TO yam 3 pams a aexnd wAAed wood paGrd'Tw ah to use.: an a tr wr
.
1 t.8G6 2(t)
mimr elema:rts of the as'CPq, eucn aaa7 Ei:.1,
I 3
!
0
B
O
Cs
12.1 AIAM I
aldnet'y u m:'p—%
6fi3 2(2)
TWO c0ne1 vem•tusyl oraexs are w.xl !e:
IT.
aam 4 RIM. a :e M carl.MM vnod ped.d mLe. 4!- M .-0 as a r.,3,bl
+ :1 P3.6 2n
.map. _ emxm Of theb.11mg, a'ach as at'-1w,
( 4
tlemeM'
8
9
f
D
Os
i iZIIA am
10—w—f
t
Madrtas tch1e3
oaur
heisecsnCcLgmSa;tn
:rtrqna:e .dfemrs.V,a3`i
fl
Po)a Te oddof he
l:E13
ohIpnary mnufarudrg Frcna em7 en vd
5=
�'5
ixik!,2 aoa: mx cmaroxfaoaj" Inept
f
f
D
OsG]
cj
.m.`.ntaenrm;ra„usdme
mC
x7"'a
ene cM:b
i o aam 2 pcY!ts vairy naldial c PlcducM, 6!t'ss ra:araaA, or xu naluraAy
-
.;
lead:
w n5C0mlles(605 lun) of Iha Po site;f traraxEed W WaR ISQ0 mlee 12414
'un) If ;rannpaned'u.11.. 80% of the:c5l ciz;arce byral cr m!•: Fraducb
f' 1
C{9.1
fi +cna!ma!er!a's
10.a¢.
am alsemhkd a< pcduxd hom muitiga rrx—Wla!s qeP 1`1 d dr'rr.{gMed
O
O
O
avm0e(M„eklA u'nh:mn)of the d6GnttI P.4 rrx:ru!eiak ha+e Deco
L
J
b-axr--d mntl the di:lanx cMnUb
f
701.4 J2
Irnu.'Y,;anad a6 se,r`aq bl1n55M :naxnrtfar!w w:.fi a?:ne;eYarnnB,m
— {-:
{. ••y `"{'t"""'e
4 r•i'
1 /.701 4.].2
4nsulat'cn and av —!,,a{
3
15—
a, ptlade
}
i
q
'l
�''- '.(
O
G
12!70143.1
(1)%Id-(AR/—AgyN Farf—J15 PM,
i21'na Cu4d-mrcl venflaldon pedorned ]yb
r
S:u1um1 pki, 'aw usM :or 1-,, -11, a1TYaf foal
aheatN; q ornPFes I;; coc PS 1 o.p.'u ccc PS
9a14{t)
Z: t358 w.etl tt Ibe:, xr$ a,"Ju roM she5h%.np
To at" %5 a mini..mum.185M c1 CSa a ply—d in iix bWd{n0 must —W o1
11001.4{7}
camP'fes'.oilh 7t'++'?52 Panes ere rsfadc vA'JI
Ma;datory
H uhu
•
•
•
!
•
72,17a1 ail)
rnaisrj-;esl�an zo,.m?v" aNe irtdeyk
podac+s.
bekW_s Ne dhMh'ea ats Ecp—m I CT Eaienaf
(dy4codl a Fapxure I fosel.
0014;6)
rtoroeaMW F.&-a, r W.ran inc�Ce ntn.'cturai
4
A mI f—an at 85% d pduct in tM a 16V ar_ M. k:neAad Huher pWUM.
•
e
e
•
Os
1I 001.4157
vrood haml
f =4.d7ied aeributs
C:�.wi:..'.de:.�1 = Tnk pow._bn daq net aFsM to Vra Craael
Nat. Fcotncles i e 7oca!ed m:er Tabk 1 t
m
VAR-1012 I lifts' VwdelZ Accepted and Trusted Page 5 of 6
TAQI rq 5TWMr)lU-W I i
LPsyamm 1 7jp sy.w.
44-T� I Ad-—
I
ztp sy,t_
Number f
Point.
R-shatjlng
TABLE d.-SUMMARY OF AREAS OF SLEGIBILIV VA7H I.ISGBC'S LEED FOR HOMES 2OC8
3 pa-t, mem 7,! -,-.7
EA I JAII:ltlrat�. 1 3— =.r
t , cf V.. d,t �Ut.
Jf
0
0 5 .0
7. tr., Per
is ea, P.!= tm art re--d, "I
pt,ta pvldl� *l. -4 A of Ry A -
At? 7 71.1
3;tath ,.J- jus .4
TABLE 7-SUMMAPY OF AREAS OF ELEGISILITY WITH USGS,-'S LE20 v4 HOMES
To t." I or V!ta,��ge fV1,5 fttl;�. o7,73V cro
7 7777-
a
0
jan
MR
nc WAM Zap= -od
Aq,,.W tst to rialtr�i a, cuSPM W Fsc or
2
2
?5;--r 74 tam �Z%, Ir-ry -.0 P am r4lla-1,
, !bt V. F., . mj,an_ 50% (L/ w-t(;H orllq-e).fl
Opttn I late woad P!c ttWied by FW Of UFGBCa,IXae_ tquv..lofAF :F
I wraoa..Pcsn. predate
EQC2
IL,� t�.�Ag =tU4
1
Ti-f
0
A
TABLE S-SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED 2CO3 FOR NEW CONSTRUCTION AND MAJOR RENOVArCN
I
IT. — I P.!,I u,d Pdw13 that .,. .=:td. 94 arw manuhaurM nrtJri O
OTWt, (ECS ++.1 Lt ) . It kr a.l. M_o,. IG-A Toy Val t- -11 .1 di.
Pue. Ta 2 pomtt It a mrrdmum cf 2010 I O
0
0
0
MR 5 2
rlos at cmtivtrl�
2
O
0
c
2
2
7
2
KIP. 7
ct..'oJd
1
e.. 1 p.,M tm. P..I* w,A Wld--1 wrYami, sdtai -a.
.EC x.4
1
17,
TABLE 9-SUMMARY Of AREAS OF ELEGIBILITY WITH USGBVS LEED 2009 FOR SCHOOLS NEW CONSTRUCTION AND MAJOR RENOVATION
I
To .,. 1 oa:nl aBt prMWa=1 af, —. of f, praod .d.lt
c
0
zl�
SUD min PC5 I=) aftrld sot fol a m-famum 21 10%(bry �p of I -
veN. T. ..n 2 X.I. syo . M6erun of 23%,
17
MR 5 2
matcrub (2% .1 oomA)
2
0
O
O
0
MR 7
_Re(;'4u)
JCW C-tdWFd
1
To eam t 1 .!.-.n 5as (mta on coati Ct wood.-:
2
7
2
2
2
to. I polm sse wo.V —;.A. -A paou m tam.k,rc,.g -Wed
EQI 4 4
Lzw w.XN _lwlah
1
rttiro
03
TABLE I rSUMMARY OF AREAS OF ELEGIBILITY WITH USGBVS LFED v4 BUILDING DESIGN AND CONSTRUCTION (36�C)
Sv of row rntcOwls - =M%�cr. of -m-vd
Z L�3t temWprDd= R AW try FSC . Usclb"rp-m
2
2
2
1
2
I
loot-
-eng fl-_ M.Acl Opw. 2 may Fc e'-Vlblt W dotl
mpt3
WA
JP,.du
crCi b-td Cl
3
Iooac_ rely
an *,. 1. �ld UP
s2t22
I- -IMN malcah
MIA
jEVW and Wnd r pmduct3 do rat apply the =Potet 'Amod pfaa� Wrift.4
=Q- - P.-
• :Vaffi-dxUibdo
Th. V-k;e.d- net apply to trd. Pdlll
Note F�atraot .. k-Ld 2t. Tad.- 11
VAR 012 I Mcst 00daf/ Accppfad and Trusted page 6 of 6
TABLES 2 THROUGH I tContSnuedl
?atil3lo
A9vmfTccrl
7'P SyVam
0.:VmiTsJ!�
ZIP Syat m
1 zP SJ.sre'n
4:+m�er
C-dicna.1 U.. m aJ.Ry;a p.;,
Pans
SinaG:(;.a
Rwf
Fkcrl*.y
Wal!
AZh_Ml!�
Stwa:9lnp
SSaYJ'J0
TAB' E li—SU,LL'AARY CF AREAS OF ELEGIBILITY WITH ANSUG61 01.2010 — GREET SUILDING ASSESSMENT PROTOCOL FOR CO,'d31ERML SUILDINGS
10122
L'!nG- nax?n+'.. •=ui441g awe^.dlo I 7 m r IAS;iUne: %Wd r-di:cb se;ua!,'ad as Hcb—I
s �1I •�'
---
a 01
We ^ffiCM,fc.TStU a'e r9a�L! �•:tri
j•—.J_`
S
jI ;<•
:.•y+,.a'.al'li'en.l9. dac•r9 Ass<9rn:es � .ru i Lc'9i2.75!�+)ctY.a 9de'?'a:^fr.:-a._..'Y7i (.••; ..-;rt :: ;e?.-�'�f'r.
C O � O
�
G
�
10 72 • ..
1 far;l 10!S w'd �C!i c:"ncre al wTfii>lttl'J�'X.�! 1:'1'.`t J,iry;i,J 2rG
'-:r!a:tr11._'rd 5raa
ja^4 net
A 0
OS j
Ii 0o���i
Sfx:cipnna
Tr::n T'AeOn :Oel rdf a49q :o:ria JI�V.'!
�vGIH,
,.:2'nGSM � fTi'nriC U fFC manLraCu'xr a.'.:/ Vendar Chan e(C..,CC.;a e'fa! rC,!�'rxi L G'JaO,•/ !p •.�.P'}n!i�f
rFarsr ar..Pu¢ian .rd'fu LeEO : `e9 rca:rres F&C nac9`reiy ard!o-' LEED M xuxa'am Caron^.. LSl3C• �' a Izi N apu:ro!; ryun:krt drama
.._ 25•2 reer4r¢ .-pa ct wa c! ee.: e_ a.. --.fir :•peer xev:i,-xx^t
, `:: ar-.J a wr x cvn.•.ad•a2'!:rm ,xev�zrs U cq a a n LEE] ITu!.e 11 beea�sa Y.e Ca;ran9a Ar 9x:mes ne:m iC,1P81 dces ,y *m1e!- ery:rnved +.�oa ,sties ¢..-sx •,rts
'tr, -.-/ aDa!eJ an'/ Lana rn a qi-i tt<Y.+.rvj pYOn cr x'e morel
`.7agtwnu'xrtal ;a'«1Jcn h:um Jn ar.1x� bca!on ;rwdeE tr/ Huuxf'.acn rc�un:
VA . NO.M( .ble