HomeMy WebLinkAboutSET-UP MANUAL ADDENDUMs SET-UP MANUAL ADDENDUM ❑ter❑ jAqOBS N HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA (727) 726-1138 NOTICE These specifications and drawings are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific purposes and must be kept confidential and secret from others. REV 01/10 ALL HO.MES'SET IN FLORIDA MUST COMPLY WITH DMV RULE 15C EFFECTIVE MARCH 29,1999 For information on 15C- contact the Department of Motor Vehicles 850-413-7600 I NOTES: ADDENDUM EXTERIOR HEATING/COOLING DUCT DUE TO THE NEW THERMAL REQUIREMENTS INSTITUTED BY HUD, THE INSULATION VALUES OF THE MANUFACTURED HOME HAVE INCREASED. IT IS NOW NECESSARY FOR ALL EXTERIOR DUCTS INSTALLED ON JACOBSEN HOMES HAVE A MINIMUM R-VALUE OF B. ALL HEATING AND/OR COOLING SUPPLY AND RETURN DUCTS EXPOSED DIRECTLY TO THE OUTSIDE AIR. SUCH AS UNDER CHASSIS CROSSOVER DUCTS OR DUCTS CONNECTING EXTERNAL HEATING. COOLING OR COMBINATION HEATING/COOLING APPLIANCES SHALL BE INSULATED WITH MATERIAL HAVING A MINIMUM THERMAL RESITANCE OF R=8.0. WITH A CONTINUOUS VAPOR BARRIER HAVING A PERM RATING OF NOT MORE THAN I PERM. WHERE EXPOSED UNDERNEATH THE MANUFACTURED HOME. THE DUCT SHALL NOT BE IN CONTACT WITH THE GROUND. /DUCT SUPPLY OR RETURN DOLING_ SSOVER USE MINIMAL AMOUNT OF DUCT. LIMIT DUCT USAGE TO REDUCE THE AMOUT OF BTU/HOUR LOSS. DO NOT OVER BEND OR CRIMP FLEX DUCT, THIS WILL RESTRICT THE AMOUNT OF AIR FLOW THROUGH THE DUCT. USE STRAPPING OR OTHER MEANS OF SUPPORT TO PREVENT THE DUCT FROM COMING IN CONTACT MATH THE GROUND. PLACE STRAPS AS NEEDED TO SUPPORT DUCT (DO NOT RESTICT AIR FLOW BY OVER TIGHTENING SUPPORT STRAPS). ALSO SEE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR DUCT INSTALLATION AND SUPPORT. CANA APPROVAL: 'PROVED BY .IUN 1 5 T995 INC NOTICE DRANK BY: DATE REV. LETTER: JACOBSEN HOMES TNESE SPEonCATIMS AND DRATINa C.L.Y. 5-30-95 0E0NAL PROPRIETARY, AND CgUVENTI& DRAN4IG TITLE: IIATETbALS OF .IAMSEN U*ffACI"C EXTERIOR A/C DUCT P.O. BOX 368 NC 9" MATERIALS AM FRONDED TO 1NE SAFETY HARBOR. FLORIDA 34695 RECPQIT MR SPEOX RlR9S MG MUST BE DRATMNG NUUBER: PHONE (813) 726-1138 A'EPT COHT,ETITK AMU SEOU ERCU OTNERS AD-AC-0001 C ADDENDUM WHOLE HOUSE VENTILATION SYSTEM YOUR HOME HAS BEEN EQUIPPED WITH A 'WHOLE HOUSE' VENTILATION SYSTEM. THIS SYSTEM HAS BEEN DESIGNED TO MEET ALL THE REQUIREMENTS SET FORTH BY THE UNITED . STATES DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. THE WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED (BY HUD) TO EXCHANGE AIR DIRECTLY WITH THE EXTERIOR OF THE HOME. THE PURPOSE OF THIS SYSTEM IS TO GIVE THE HOME OWNER THE ABILITY TO INTRODUCE FRESH OUTSIDE AIR INTO THE INTERIOR OF THE MANUFACTURED HOME, INSTEAD OF SIMPLY RE— CIRCULATING THE SAME OLD, STALE AIR THROUGHOUT THE HOME, THUS IMPROVING THE INDOOR AIR QUALITY. THE SYSTEM INSTALLED IN YOUR HOME HAS BEEN DESIGNED TO GIVE YOU COMPLETE CONTROL OF WHEN AND HOW THIS SYSTEM IS USED. YOUR HOME IS EQUIPPED WITH A FAN THAT WILL EXHAUST STALE INDOOR AIR (TO THE EXTERIOR OF THE HOME). THIS FAN IS SWITCH CONTROLLED AND MAY BE MANUALLY OPERATED. TO DISCCNTINIUE USE OF THIS SYSTEM, SIMPLY 'TURN OFF' THE SWITCH THAT CONTROLS THE FAN. NOTICE TO HOMEOWNER Whole house ventilation switch You will be able to locate the switch that controls this fan by locating the switch that is labeled -WHOLE HOUSE VENTILATION. (See AD-AC-0100) PIA APPROVAL: APPROVED BY ��{{ N14rr O, SO INC. mmx M R1�A10RN[1t/E11CIM>♦ NOTICEDRAIM BY: c.L.Y. DALE: -28-95 Rtv. alMpr MEJACOBSEN HOMES 1»SESK�TISAWDRAMM Mr�o1 o Aoa� tj DRAriwc nnF SYS. M amm u W.H. VENT. P.O. BOX 368 w— s m MAfE► s ARC PRW = 10 WE SAFETY HARBOR. FLORIDA 34695 PHONE (613) 726-1138 RERpORT FOR SKOM P111r= AND MW r PvT cmm m AND 100 nm 0XIM GRAVING NUMBER AD—AC—OIOO 3 ADDENDUM MULTI -WIDE UNIT FLOOR FASTENING n nne v.io%T 0.131X . �,,, NAILS OR 7/16- X 16 GA. STAPLES PER TABLE: 0.016- X 1 1/2- MIN. STEEL STRAP 0 480 O.C. MAX. SPACING WITH FASTENING INTO JOIST EACH SIDE OF CENTER LINE PER TABLE BELOW: FOR GAPS IN FLOOR SYSTEMS NDS01 TO 1/Y. INCREASE LAG LENGTH 1' (ALL ZONES) AND FOR GAPS TO 3/4'. INCREASE (ALL EXPOSURES) LAG LENGTH 1 1/2'. -/ - .. • I � mu•. &.nv li'l w . r D SEE CHART FOR MAXIMUM SPACING, STAGGERED FROM SIDE TO SIDE AT AN APPROX. 45' ANGLE FROM VERTICAL. SEE DETAIL BELOW IF GAP EXISTS BETWEEN FLOORS. 1 4' TO 3 4' GAP WOOD SHIM AT ALL LAG LOCA71ONS FOR LAG SCREW TO GO THROUGH AND TO KEEP CONNECTION 71GHT. (SEE NOTE 2) we ZONE O6" K 3/e• x 3 1/r LAG S=x JO 7 r /1 SWAP FAS x 1e cA. sTAPL15 AK M/ WWUW MA M;R Cr FAS1E OM REQW0 WA7OIAJ<1 SPACNG KA)NttJil SPAONG We 201E DAt'GsuRE 0.131- X 1 1/t NA1r.S 7/1r X 1e GAL STARES 2 $! 1r aC. 2 1/4' QC. 3 S b' 1r cc.1 7/S• OrC 2 b• 4 7 3 'r 1W 06t Y aC 4 7 3 b' 14• aC 1 1/Y' aC. b• S e NOTES INGHEFB APPROVAL• CAM APFi{OWAL- t. 1' WRL PORMAIM 5 REMO OH STAPLES FOR MIL aO14' STRAP. APPROVED BY 00oRevised ON J-' Z MW SINS TO BE Rl F FROM SPF Al UK OR BETTER (3' x 1' XIMDOD GAP tD1H MDL 9I� (OS8 OR PLY May 24,2006 r rl WAY K USED F A1MESS EQUALS GAP NDTH-4' X r LOL SIZE) John C.Lj0 den. F? �. N C 3. We WAN" SMALL tE1r tT. 4. SEE OMMUS FM SEALM FLOORS FOR AIR KLTRAWL . K2 Eng:rmring, i•!.^, . FEDERAL MMUF&CTUREO "OME crosrnucno" mo "I ETY SM "Mos JACOBSEN HOMES xorL" nasc �carra>tox AIO au.+a iwE DUN BY. M.T. DATE 05-22-06 ray. LLl1EIt 1170-1 P.O. Box 36e aAuaw, IFFAFR A@"* AIO mi1oE11tuL "A11O°"� +ABMWA,~,rAcn, 3XN0 n DRAMNG ITM M/W FLOOR FASTENING SAFEiY HARBOR, FLORroA 34695 PHONE (813) 726-1138 I� jg r � gyp b7 i CM ONEOn DRAW Hut L AM OW RM MW AD-FA-0001 4 ADDENDUM MULTI -WIDE UNIT WALL FASTENING ENDWALL NDS01 NOTES: 1. FASTENING REQUIRED ONLY AT MARRIAGE LINE OF EXTERIOR WAILS. .131- X 3 1/27 MIN. NAILS 8' O.C. MAX. SPACING, STAMM FROM SIDE TO SIDE (TOE -NAILED). MARRIAGE LINE APPROVED BY Revised s 2j Ob May 24,2006 Huhn C. Doeden, P.L. INC. K2 End p ring. irtaCX"WMMNO WIrrtMOAM JACOBSEN HOMES wnc � WAUM OK ur of- M.T. 05-22-06 "" �`•"" P,o,ANCIAM eox �`' la M �`�` °a' M/W WALL FASTENING B wmws v +�oor�w w�r�ea�o 12110 SUMNe za wwws M Toyota A x ctE(813) �i25--iise�9S on o mm s sm n m cum °� �' AD-FA-0010 . ADDENDUM MULTI —WIDE ROOF FASTENING 30 'GA. GALV. STEEL STRIP — < SECURED WITH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING (SEE CHART ON AD-FA-0001 MAX SPACING). -LAG SCREW SET BACKS FOR TRIPLE WIRES FOR DOUBLE WIRES TRIPLE WIDE ROOF LINE INSTALL LAG SCREWS I AT A 45' ANGLE STAGGERED __AS!= CENTER LINE OR MATING ! LINE OF TRIPLE WIDE UNITS —30 GA. GALV. STEEL STRIP '8' X LENGTH OF ROOF (SECTIDNS MAY BE OVERLAPPED 2' MIN.) W/STAPLES AS SHOWN. INSTILL.. ROOF CAP PER SET- UP MAN. OVER GAL STRIP. (30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONOITIDN, EXCEPT FOR STAPLE HOLES.) PLAN MEW f3/6' X S' LAG SCREWS .AGamLAG SCREE SFr aAcKs (2 1/4' SMOOTH SHANK) FOR DOUBLEWNIDES If+� SFE CHART ON AD-FA-0001 .� FOR TRIPLE WIDES FOR MAMUM SPACING 4' 21 4 234' 1 TO 3 4' GAP ROOF PERIMETER RAIL --- OR RIDGE BEAM (FOR RIDGE BEAMS SEE NOTE 14) CROSS—SECTION NOS01 (ALL ZONES) (ALL EXPOSURES) FOR GAPS IN ROOF SYSTEMS -J �' INSTALL WOOD SHIM AT ALL LAG TO 1/2'. INCREASE LAG LENGTH 1' LOCATIONS FOR LAG SCREW TO GO AND FOR GAPS TO 3/4% INCREASE THROUGH ANO TO KEEP CONNECTION LAG LENGTH 1 1/2% TIGHt (SEE NOTE 2) REF CALC. PG. CROSS—SECTION (W//�). C WA- 91.01- 91.07 NOTES: - OIp W APPROVAL: DAPLA APPROVAL• L 2 I/r WL FOCPARON N10 RECOW4 Mom 6 REQIA a FOR LAG SORm 2 IIDOD 3m TO K RM'PiD FROM SPF IP MR OR BETTER APPROVED BY (r x r x WP mm WL sap ON Revised 0® OR PLW11oOD WAY BE USED F OfCIQiE35 EQUALS GAP 11DTF1-4' X S' MR9IF) S All 24 , 2006 MHDL MLS L SET ODD DETAILS RX COLFLETING ROOF ti1FAECTIOIL John C. U06CIen. P L INC. 4. TALLNG A IAG SI7tE1M N10 A RR a BEAM, FIRDRLL ST-A 3/e aE#Ra NOTE THROUGH THE FIRST RDOE BEAK SECOID-M A 1/4' HOLE 1WOCH 1FE K2 Engk*erh Ig, Inc FEDERAL MANUFACTURED HOME WMM RIDGE BEAX FM THE TI AO Wo DF LAG Si r HN DNS. ARE ' CONSTRUCTION AND SAFETY STANDARDS FOR 3/EF' Lm =RED OLT. s IOr MA>0 N SOENAIL FIGHT. JACOBSEN HOMES DIM $Kwulm wo Ouw= ME °RA"" �' M.T. DATr: 0s-22-06 "� LFr1M awWAL PIIa�EETNET. No OOHT,DENM D V-4 11RE 01—wrlP.O. Box 368 „W4,,,� WACA 4 M/W ROOF FASTENING SAF1T' HARBOR. FLORIDA 34643 wool Fm HEW= NO MST NE DRAIFNG I l=t PHONE (e13) .726-1I36 WT amewm#L NET =r OnMEL AD-FA-0020 6 METAL ROOF RIDGE CAP DOUBLE WIDE UNITS ONLY PLAN VIE 29 GA. MIN. GALV. STEEL RIDGE CAP COVERING IBM OF ROOF (MR Y OVERLAP AT SEAM) CENTER OR MATTING LINE WITH 0 X 711C HEAD X f FULLY THREADED SCREW AT EVERY RIB (AND ON BOTH SIDES OF RIB WITHIN END ZOO 1 1 1 ASPHALT IMPREGNATED SEALER STRIP BETWEEN RIBS 1 OR CLOSURE STRIP RUNNING ENTIRE LENGTH OF ROOF / / / ■ Ref: EX-13-0051 and AD-FA-0020 NDS01 (ALL ZONES) (ALL ) X 7/16' HEAD X 2' FUULLY . THREADED SCREW (NO MORE THAN 12' O.C.) •I I •I o 1 8 IB 1 � 1 1 METAL ROOF PANELS STOP ■ APP. 3O FROM CENTER LINE `-30 GA. GALV. STEEL STRIP 5' X IBM OF ROOF (SEE AD-FA-0020) SECURED M 7/16' X 16 GA. STAPLES FULL PENETRATION DIM DECKING (SEE CHART ON AD-FA-0001 MAX SPACING) NOS: tWWM ArrKU N.: Nvu MIL : SEE OTHER DETAILS FOR CONNECTIONS BETWEEN SECTIONS APPROVED BY L STANDARD 7/16' O.S.B. (24/16 INDEX) ROOF SHEATHING. L METAL PANELS ARE 29 GA. MIN. STEEL WITH 9. O.C. RIBS. V 4j 7 Sep 10,2008 I. SCREWS HAVE A NEOPRENE WASHER FOR WEATHER PROOFING AND 1HL►',,'x'�,i;, .� INPIINC. TO HELP AVOID OVER DRIVING. IF SCREW IS OVER DRIVEN g, ETTG FEDSKCONSMorno FAMD swm Srr w mos ANOTHER SCREW MUST BE ADDED BESIDE THE INEFFECTIVE SCREW (DO NOT REMOVE OVER DRIVEN SCREWS) JACOBSEN HOMES '"`""" or w= RK:slwc „� �, „� D.M.T. 08-25-08 ORMUL lums oR,ur+s T111k P.m Box 366 w om wows m twm m n METAL ROOF R1D( CAP — s imn Fri W� 30 es o" n aw m oom AD-FA-0021 7 ADDENDUM MULTI=WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING \ (SEE AD-FA-0020) 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT RECOMMENDED EACH SIDE DAPIA PROVED BY 11HINC ft �c.AACtW,D How C� V� MO S�fSil37AOYC� NOTICE: DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES THESE VEOnCATTOws AND DRAWNOS ARE C.L.Y. 6-5-95 ME MONAL. PROPWAffY. AND DON)IDE YK DRAWING TIflF ,/ P.O. BOX 368 LIAR OF AkCMSEX °ANWACMUC M/W ROOF SEALING We 10 MENU ARE PROKED TO flQ ORAwDIC PIUYBER SAFETY HARBOR. FLORIDA 34695 REOP[M rcR FMRNM AND MW eE PHONE (813) 726-1138 IOPT ODWWTK AID 1=1 n= OTOM AD—FA-0025 8 ADDENDUM MULTI -WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING (SEE AD-FA-0020) 0 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES - LOW SIDE NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 6" STRIP ROOFING CEMENT REQUIRED OVER EDGES - HIGH SIDE. 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT (2 BEADS REQ'D HIGH SIDE 1 BEAD RECOMMENDED ON THE LOW SIDE) ROVED BY JUN 1 5 W5 1 11" 1 INC. c""W-MUMM N097CE: DRAWN BY:. DALE ��• �"K JACOBSEN HOMES TaxSPEC=TIONSWDiUMM6ARE C.L.Y. 6-5-95 mcmm . PROPRaART; " Oopffl nnu DRAW9iG TIM YATMAIS W 1ACOM UWACIURN M/W ROOF SEALING P.O. BOX 368 W_ 20 YAIERIALS ARE PROrICtD TO THE SAFETY HARBOR. PHONE (813) 726 1138 95 IV ra TK m � � or�►r�►+G Nuueat AD—FA-0026 9 SHIPPED LOOSE HEARTH EXTENSIONS HEARTH. IMAI i.ATTON• 1. REMOVE ANY CARPET AND/OR PAD FROM UNDER THE HEARTH EXTENSION AREA 2. INSPECT THE META FLASHING IN THE HEARTH AREA TO WCURE THAT IT HAS BEEN NSTAI1fD (THIS FLASHING MUST BE PLACED ON THE FLOOR TO PROTECT THE AREA BETWEEN THE FMUCE AND THE HEARTH d LOCAIE THE IIEARIH EXTENSION (SHIPPED LOOSE N THE HOME) AND INSTAL FOLLOWING THESE STEPS A. CAREFULLY PLACE THE HEARTH EXTENSION IN THE PROPER LOCATION IN FRONT OF THE FIREPLACE ASSEMBLY. B. SECURE THE HEARTH EXTENSION TO THE FLOOR W/ 4 j8 : 2' WOOD SCREWS. C. FILL THE AREA BETWEEN THE FACE OF THE FIREPLACE AND THE HEARTH EXTENS10N THTH A NON-COMBUSTABLE CAWG OR MORTAR D. OR FOLLOW THE HEARTH MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. TILE SURROUND Imilill mmI TYP. HEARTH (MAY BE SHIPPED LOOSE) 1. A TYPICAL TILE FRONT FIREPLACE IS SHOWN, HOWEVER THIS DETAIL APPLIES TO ALL FACTORY INSTALLED FIREPLACES. (STONE, WOOD, GYPSUM, TILE, STUCCO, ETC... MAY BE USED IN LIEU OF THE TYPE OF FIREPLACE SURROUND SHOWN ABOVE.) TYPICAL WALL WOOD TRIM FACTORY INSTALLED FLASHING DAPIA APPROVED BY INAJUN 2 8 19% r!Dlft WVACRMH R INC, Nonce gymm cr.. un�c: NLY. LLIIM rrrn JACOBSEN HOMES TNESE SPECM114" ANOORANWGS ARE C.L.Y. 6-16-95 ■ OMONA.. PROY'WARY, AND C-wvTLAL DRAWNG TITLE: P.O. BOX 368 MATERIALS OF .IACOM MANUFACT"G SHIP -LOOSE HEARTH „ 1141 SAFETY HARBOR. FLORIDA 34695 XCIPID4 FOR FM Y PJNZ NO ,lu° Y K PHONE (813) 726-1138 IVY CaWi TIX Rio SEW TROY ONERS ORAWu1G NUMBER: AD-FP-0001 10 SMOKE ALARM ADDENDUM Enclosed in the home owner's packet is the smoke alarm user's manual, (if it is not there, contact Jacobsen Homes and one will be sent to you. NOTICE TO DEALER AND SET-UP PERSONNEL This home is equipped with a smoke alarm system and must be tested in accordance with the smoke alarm user's manual after the home is completely set-up and all the electrical connections are done. NOTICE TO CUSTOMER Smoke Alarms have been installed in your Jacobsen Homes. You should be familiar with the locations and operation, and learn how the alarms can be silenced once they have sounded and be familiar with its use. This is a very important safety device installed for your protection. Be sure that it is kept in A-1 working condition by testing if frequently in accordance with the manufacturer's instructions. The alarms operate on household current, and have battery backups. Its purpose is to provide early warning in case of a fire. Again we stress the importance of keeping your smoke alarms in proper working order. TESTING SMOKE ALARM Test smoke alarms after home has been set-up completely. To test the smoke alarm, press and hold the test button on the cover of the unit, until the alarm sounds. All smoke alarms should sound alarms. If all units do not alarm, replace units immediately. This test should be given to all smoke alarms individually. APPROVED BY REV. 0 000or 9iAR 25 20 PINC. FEDERAL MANUFACTURED H041E CONSTRUCTION AND SAFETY STANDANUS SET-UP MANUAL ADDENDUM AD-FS-0001-A 11 TRUSS SHEATHING APPROVED EY INPIANC. FEDERAL MMUM LIRED "OWE MNSiRIJCTIONANDSAFETYSIA DIM DEALER (SET-UP)INSTALLED PLYWOOD FOR SHEATHED TRUSSES HINGED TRUSS - NOTE: HOLES TO BE CUT IN SHEATHING TO ALLOW OUTLOOKERS TO PASS THROUGH. TYP. OUTLOOKERS I FACTORY INSTALLED PLYWOOD FOR SHEATHED TRUSSES L SIOEWALL 3/8' WIN. APA OR TECO RATED SHEATHING APPLIED TO ROOF TRUSSES LOCATED DIRECTLY ABOVE SHEARWALLS (APPLICABLE TO ALL SHEARWALLS) MARRIAGE WALL PENETRATIONS OF THE SHEATHING ON THE TRUSSES) FOR —` THE OVERHANG OUTLOOKERS (PURUNS), ATnc VENTALATION. 3/8' SHEATHING TO IE INSTALLED ON —SITE OPENINGS IN TRUSS SHEATHING MAY 8E LOCATED AT ANY LOCATION ALONG THE LENGTH OF THE TRUSS. VVINDZONE III (IB' X 14 I/2' AIAXIIIUM SINGLE OPENING SRE IN TRUSS SHEATHING) MPH)NG) ALL EXPOSURES NOTES: ENGINEER APPROVAL: DAPIA APPROVAL• 1. 3/8' YIN. RATED SHEATHING FASTENED TO ROOF TRUSS WITH 7/16' X T (NOIEDGES AND J• D.C. APPROVED ALL FRAMING MEUMS. QUE REOUDiED) AT BY MAT > a Mvell, .E. NIP INC. FEDERAL MANUFAMIRED HOME WNBTR OKMANDSAFETYSTANDARDS z JACOBSEN HOMES NOTICE: THESE sPEaFlunons DRAWN BY: R.R. DAIS 4-27-98 REV. LETTER: 00 ■ AND oRAlrolcs ARE ORIGINAL. PROPRIETARY. AND CONFIDENTIAL DRAWING TITLE: BOX 368 P.O.11AWRIALS „ OF JACOBgN MANUFACIURNC SICH MATERIALS ARE PRO�TODI TO TRUSS SHEATHING — SAFETY HARBOR, FLORIDA 34695 PHONE`. (813) 726-1138 REcpENr TpR wax S AINC. gE kEP1 cONnwNuu AHD SErnn rROM o1N[RS. DRAWING NUMBER: AD—HR-0001 12 HINGED ROOF DETAIL OlS mm ff =ml m RA& Roll flm WNO P09110Ti m xr-1P Po31u 15 APPROX n 1 /Y. w ma ROW mm SY61E] imy" llEA1MIPJIL OEM015 NO NX Im 12 w APART. IDLE wu mm wm x' OF BD ff ROW SEM A10 AVW WW WA 2 Fi>:TT aF A YM N ROM RAIL HINGED ROOF IN SHIPPING POSITION IN® W Posr 10 ROM WK i SPF JIFORD W Post 10P RAI. pt oxTorosmORs-lair am HINGED ROOF IN SET—UP POSITION REF. CALL. PG. C-RF- 223.0 - 223.6 NDSOI NOTES: 04MM APPRovx: DAPK APPROVAL: APPROVED BY I. BRACE Un ROOF BECKON N VE RAW POSU ORK S191 W HIDED KBD Poo Km PCs(DOH Revised 'N 04 �, os,2oos JohnC. ooFl, PA. INC. K2 En rin, Inc FFD� YANKACTINFD HOW 9 CDNSTRUCnON AND SAFETY STANDARDS JACOBSEN HOMES mr9m `imm O" O.A. 06-02-06 ....... L WOO M' WO NO ORAUM ARE �L'MWW wmlL °A HINGED ROOF OETAII PA. Box See wT+rws os � mG,=X w+e NG 2= UWULS NE MOM 10 K - A PHPHO EA (W) 72ffeD1-1i395 Wa mriwOCw "m�rno maurae AD-HR-0002 I HINGED ROOF DETAIL U NDERLAYMENT TD BE CLUED 3' MIN. ON BOTH SECTIONS OF HINGE ROOF. FOR WIND ZONES 2 AND 3. RAISE EXTENDED SHINGLE AND UNOERLAYMENT AND AND A YIN. 4 1/2' VAD7H OF ROOFTdG 'CEMENT TO 70P OF LAST SHINGM ROW ON FIXED ROOF SECTION. (THIS IS TD BE DONE BEFORE RAISING HINGED ROOF SECTION.) SHINGLE AND UNDERLAYMENT CEMENTING AT HINGED AREA ATTACH 2 X 6 X B' BLOCK'BEWID 2 X 6. OVERHANG FASCIA BOARDS AND SECURE 07H 3-fS X 3- WOOD SCREWS EACH SIDE CF CAP. APPROVED BY Revised ON Alm.ov 30,2006 �p� FEDERAL YAIUF1NCi11RED NONE MRSTRDCTIDN AND SAFETY STANDARDS �17,6 BLOCK ATTACHMENT AT FRONT AND REAR OVERHANGS VANOZONE 11 (110 MPH) ALL EXPOSURES NOTES: E11GK8 APPROVAL DAPIA APPROVAL; I. PACE b= ROOF SECTION N X RXW P0971ON DYCK SWUNG HIKM KING POSTS INTO P0.911p1 John C. D K2 Engina*** Ine• JACOBSEN HOMES ma O me Amm An m'" Br. D.T. oAtE 10-02-06 abut. Mall 00- AW UOMM& DRAWO 117M. WWIMS OF JACCe.Sf)I NANliACTI Mc P.a Box SeeHINGED ROOF DETAIL SAFELY HARBOR. AR. FLORIDA 300 � R "isms AM ME rmmmRU K DRAIIINO NIA PHONE (613) 726-113B Ian awmm me s m ON ffom AD—HR-0003 14 SHINGLE AND UNDERLAYMENT APPLICATION ON HINGED SECTION INSTALL ON SITE 15# FELT WITH A 6' MIN. OVERLAP ONTO MAIN ROOF CEMENTED WITH ROOF TAR AND SECURED PER NOTE #2 CONTINUE 15# FELT TO ROOF PEAK qcn aS =WKL 1`I11J1 KVYI Ur JI INULL IV 0L INDIALLLU UN SITE WITH • 6 STAPLES (1' X 3/4' X 16 GA OR ROOFING NAILS) PER SHINGLE MANUFACTURER'S INSTRUCTIONS AND CONTINUE TO PEAK. DETAIL A REMOVE THE ONE PIECE SHINGLE UNDERLAYMENT IN THE GAP (HINGE SECTION IN DOWN POSITION) BEFORE LIFTING THE HINGED SECTION OF THE ROOF TO ITS FINAL POSITION AND BEFORE INSTALLING THE 151 FELT AND SHINGLES. VNNDZONE III (110 MPH) ALL EXPOSURES NOT�71 oiwA APPRotra: 1. CEMENTING OF 15j FELT IS NOT REWIRED IN ANY AREA EXCEPT WHERE NOTED. A PROVED BY 2 FASTENING OF 15/ FELT IS NOT REQUIRED. (FASTENERS APPLIED JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) 3. THE FIRST LAYER OF ON SITE 15E FELT ONTO THE FIXED ROOF A ITN. OF 6' AND UNDER THE LAST EXTEND COURSE OF FACTORY INSTALLED SHINGLES IF NEEDED TO MAINTAIN THE 6' MIN. OVERLAP ONTO THE FDED ROOF. 4. INCLUDED IN THE HINGED ROOF ADDENDUM ARE DETAILS AD—HR—OOM (WITH SPECIFIC END PANEL LAYOUT), (��, ODOZ AD—HR-�O003� AND AD—HR—OOD4. FED L MANUFACTURED HOME RUCTION AND SAFETY STANDARUS JACOBSEN HOMES N0T1� 1IESE SPidHG11OIS MDDRAI�ICS AR8 DRAWN M.T.DATE: 9-20-03 REV. ` DRAINING TITLE SHII NG E AHD UNDERLAYMENT GI MAL PRIPRETABY. AMo MIFDBMX MAIERKS OF dIICaW MNffAC7UFM P.O. BOX 36Ti SAFETY HARBOR. FLORIDA 34695 W. SUCH MAIMALs AM FROWMED 1D WE WWW IMI PEOM NIfQ= Alp OW E APPLICATION ON HIMM SECTION DRANMiC NUMBE7t PHONE (m) n6-1138 RE" WOOF u� = �r I M CnU& AD-HR-0005 15 PEAK INSTALLATION DETAILS SECURE ROOF PEAK ASSEMBLIES TO - HINGED RAFTER WITH #8 X 4- SCREWS, 6.1/2" O.C. I AX. DECKING ON RIDGE BLOCK ASSEMBLIES FASTENED WITH (6) 7/16" X 1 1/2" X 16 GA. STAPLES INTO EACH 16" O.C. RAFTER AND 3 1/2" O.C. MAX. INTO 2 X 4 RAIL. (TYPICAL BOTH SIDES) �i i SEE AD-HR-0002 FOR ASSEMBLY DETAILS. NDSOI NOTES: I. SEE AD-HR-0007 FOR INSTALLATION OF UNDERLAYMENT AND SHINGLES. ' ALL VANNONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L REF' C&' CRC — 167.01 — 167.02 ENC EER APPROVAL DAPIA APPROVAL — APPROVED BY Revised 04����{{,,���� G I1JNm 09 , 2006 C John r 0. C*sd i, F.L. FEaENAt NM"IF�CTUIIEON • !92 ERgitT ring, f71G co"smucr �ro LFETY SiAlloutaS JACOBSEN HOMES P:O. BOX 366 NO11c1a: THESE VEMWADDwS AM MA1100 ME aMcmA. PaDPA1:IMT. AHD cmfmn4L MASS xta ""'"'r' MAWR UT: O.A. aA IL 06-06-06 It" lE1 RJR: n A ORAWW ARE: PEAK INSTALLATION DETAILS AT MU AK 10 THE SAFETY HARBORi FLORIDA 34695 PHONE (727) 726-1138 uawon ►a SITM rJWW AND MATT 1E mr he DRAYMG NUMBER . curcomq SIM AM almm AO-HR-0006 16 SHINGLE/UNDERLAYMENT INSTALLATION SITE INSTALLED SHINGLES (USING THE . 6 FASTENER METHOD) AND CAP INSTALLED PER MANUFACTURERS INSTALLATION j INSTRUCTIONS. INSTALL FIRST LAYER OF 151 FELT TO ROOF NTH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH ENO TO ROOF DECK AND/OR EMSTING FELT AS SHOWN. raftVgm TOP COURSE(S) OF SHINGLES TO OVERLAP PEAK AS SHOWN. SHINGLE INSTALLATION SEE OTHER DETAILS FOR 97E INSTALLED ROOF PEN( UNDERLAYMENT INSTALLATION INSTALL TOP LAVER OF 151 FELT TO ROOF WIN A 6' MIN. 1MDTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/OR ENSTING FELT AS SHOWN. OAPIA APPROVAL' :D BY . f AUG 0 1 INC. NOT10E DRAIN 8Y: OAtE: REv. LFf1EN: JACOBSEN HOMES nm' No A,4�►- M.T. 7-28-04 O 011- PIIDPNETARF. l0 W=flA< DRAWM TIRE _ IN P.O. BOX 368 WM HAM AM TOmmWACRMC AYIIENi INSTALLA1fON SAFETY HARBOR, FLORIDA 34695 KcFal F01 V= OF jM=n NIPW ND WM N DRAI PIG RIAIBER: PHONE (727) 726-1138 wI awwpA no lEw Rm a mm AO-HR-0007 ADDENDUM TYP. SHIP -LOOSE PLUMBING SUPPORT FASTEN TO FLOOR FRAMING MGM W/ STAPLE OR NAL BANDING STRAP "I PED' AROUND PIPE AND FASTENED TO FLOOR FRAMING. 4DE OF NOT LESS THAN 1/4' PER FOOT MUST BE MIANTANED TOWARD THE OUTLET. WHERE THIS GRADE CAN NOT BE ACHIEVED, NOT LESS THAN 1/8' 'GOT MAY BE USED WHEN A FULL SIZE CLEANOUT IS INSTALLED AT THE UPPER END. 1.. VIEW OF DRAIN PIPING 1. PIPE CLEANER AND CLUE SHALL ALSO 8E SUPPLIED BY THE MANUFACTURER FOR PLUMBING CONNECTIONS. 2. 48" O.C. MAX. SUPPORT SPACING. DAM APPROVAL IN . I, 9till � +: INC. JACOBSEN HOMES scx $KCMV0M'� MAW=ARE.1pD1°FU"" er R.R. DA'� 7-17-97 �V' 1EiQt` CRCHAL PROWTARY. A4 CGri7k DRAW TIME YAMNALS OF J%Me 1 YYnL'ACIUnri. PLUMBING SUPPORT P.o. eex 368 ne � w7MAIs ARE �m io n� SAFETY HARBOR, FLORIDA 34695 Iacnon Nea VW IRt14M AND V= K DRANNG NLWM. PHONE 013) 726-1138 QIi CMnODOYL PM 3EM7 nVv Gild AD—PL-0001 18 OPEN PORCH RAILINGS) IT IS THE RESPONSIBILITY OF THE SET-UP CONTRACTOR OR GENERAL CONTRACTOR ON SITE TO INSURE THAT THE RAILING(S) INSTALLED OR TO BE INSTALLED MEET ALL CODES IN EFFECT AT TIME OF HOME INSTALLATION. DAM APPROVAL NOTES. IPPROVED BY INC. N°TIcEu1tA1N9 UT: JACO BSEN HOMES wIL' IR•. ���� TI#SE sPEasicAlaRs AM DRAINNOS ARE M.T. 3-30-05 MGM. P MNVARY, MI) CartlO UX DRAWM nm P.O. BOX 368 RATMALS OF 'A�� UN"AC1t OPEN PORCH RAILIN S IXC WOO PATE W ARE PROVM TO TlIE SAFETY HARBOR, FLORIDA 34695 BECP W FOR SPECi1C PLFPM NO UMT 1i ORAVMG NUMM: PHONE (727) 726-1138 WT CONiXf" NO SECRET FROM OOERS AD-PO-0001 19 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST do ROOF), SOLAR TUBES AND PLUMBING 4 VENTS SEE AD—PR-7007 do 7009. MAX. ROOF SLOPE � FOR ROOF DECKING DETAILS SEE AD-PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE ` \ FOR ROOFING DETAILS SEE AD-PR-7002 �� SEE AD-PR-7008 SHIP P THIS SEC. LOOSE � (SITE [INSTALLED) � >�— — — — — — — — — — — — — — — — — — - FOR OVERHANGS SEE AD—PR-7003. FACTORY INSTALLED RAFTERS (CENTER SECTION) REMOVE ALL FACTORY INSTALLED FOR ROOF VENTING BOTH FACTORY — POLYVINYL BEFORE INSTALLING THE AND ON SITE SEE AD—PR-7005 & 7006 ON SITE PITCHED ROOF RAFTERS CENTER SECTION OF TRIPLE WIDE TYPI AL TRIPLE WIDE HOME REF. PG. IW-07-0011 WITF SITE INSTALLED PITCHED FOR FASTENING C ,JTER SECTION RAFTERS NOTES: APPROVED BY ON 14 Revised ct 25,2007 (INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS NOTICE: DRAWN BY: I OATS: 10-24-07 REV. LETTER: JACOBSEN HOMES THESE SPECIFICATIONS AND DRAW= ARE ORIGINAL. PROPRIETARY. AND CONFIDENTIAL O.A. D DRAWING TITLE:min P.O. BOX 368 MATE MALS OF JACOO$N MMUFACMING INC. 91M MATERIALS ARE PROVIDED TO THE ON SITE PITCHED ROOF DETAILS IVl SAFETY HARBOR. FLORIDA 34695 RECPIENT FOR SFWX PU4PM AND MIST BE DRAING NUMBER: AD—PR-7001 ® PHONE (727) 726-1138 KEPT DJIaMUL AID SEW "OUM 20 ROOF TO ROOF ATTACHMENT SECURE SITE INSTALLED ROOF DECKING SITE INSTALLED 7/160 MIN. ROOF WITH 7/16- X 1 1/2- X 16 GA. STAPLES DECKING SECURED 1MTH 7/16" X 1 1/2 (12) EACH SIDE OF MARRIAGE LINE TO X 16 GA. STAPLES. 2' O.C. MAX. TO EACH 168 O.C. RAFTER. EACH 16. O.C. RAFTER. SEE DETAIL 'A' SEE NOTE 11 11' MIN. SITE INSTALLED DECKING OW' RLAP FACTORY INSTALLED ROOF DECKING SITE INSTALLED RAFTER TOALIGN WITH FACTORY INSTA LED RAFTER FLOW. . SEE NOTE 12 18' MIN. MARIDGE BEAMS J Y NOTE /4) A I DECKING MIN CROSS-SECTION REF. PG. RC-07-0044 NDS01 NOTES: I. SECURE EACH 16" O.C. RAFTER TO RAIL BELOW WIN 2-/10 X 4 1/20 SCREWS AT EACH RAFTER END. SITE INSTALLED PIALID RAFTER. (EA.TCHED SCREW TO HAW 1TER TOA1%4 PENETRATION MIN.) 2. ATTACH MATE LINE RAFTER RAILS (OR RIDGE BEAMS) WITH #10 X 4 1/2' SCREWS 9- O C. MAX SPACM 3. SEE AD-FA-0020 FOR GAP TREATMENT BETWEEN SECTIONS. FACTORY INSTALLED RAFTER (CENTER SECTION) REF' CA= C-FS3 - 88.01 .7ohn C. 069aen, P.6. K2 EngWmwr V. Inc. WINDIO -0 ALL EXAOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. DAPIA APPROVED BY ri IHJunINC. 2006 FEOHuI rAMncACTuu4 xorE commuC710M •rD iAfEIY STAMDUt05 JACOBSEN HOMES nEscscar�u�ioameaAvansm TIM M•K..Aa•RRTA�T. we — owAw�TIT. O.A. °�� 06-02-06 ter. urn OHA n P.O. BOX 366 UMMS ulaw Am av AAO M US A1rAMM 6 ROOF TO ROOF ATTACHMENT A SAFETY HARBOR. FLORIDA 34695 OM1M 9= 111R� mlow < DRAV" NUMBER PHONE (727) 726-1138 an e0flo Tw ra Kml nog Eros AD-PR-7002 21 RAFTER TOP CHORD END ZONE RAFTER/OVERHANG ASSEMBLY ALT. CONSTR. RAFTERS 2 X 6 OULOOK IER 19' O.C. MAX. BETWEEN OUILOOKERS 2 X 6 OVERHANG FASCIA THIS TRUSS INSTALLED ON SITE BOTTOM CHORD 160' DOUBLED END ZONE RAFTERS TYP. 16' O.C. 194 00 A/qr'lz 2 X 4 NAILING BLOCK (INSTALLED ON SITE) MIN. (3) .131' X 3' NAILS FROM NAILING BLOCK INTO RIM PLATE OF ADJACENT SECTION OF UNIT, AND . MIN. (3) .131' X 3' NAILS FASTENING FASCIA INTO END OF NAILING BLOCK 2 X 6 OUTLOOKER 19' O.C. MAX. BETWEEN OUILOOKERS ALL OUTLOOKERS SHOWN ARE 2 z 6 SPF /3 FLAT SEE CHART FOR FASTENING OUTLOOKER TO TOP CHORD -MULTIPLE TRUSSES FASTENED TOGETHER W/MIN..1310 X 3' NAILS OR MIN. 7/16' X 2 1/2' X 15 GA. STAPLES 16' O.C. MAIaMUM INTO TOP do BOTTOM CHORDS ONLY. 2 X 6 FASCIA FASTENED TO OUTLOOKER 2 X 6 OVERHANG FASCIA END ZONE ASSEMBLY NOTE W/16I1 (5) 7/16' X 2 1/2' X 15 GA. (SHIPPED ASSEMBLED STAPLES OR MIN. (3) .131' X- 3' NAILSASSEMBLEDFOR SITE INSTALLATION) TO �70 (TYPICAL AT ALL CENTER BRACES) IN TFE ENDZOTE PER FASMG 001. SINGLE 11AISS ONLY REQ'D OUTSDE OF 3 FT. AREA SS MAY BE PLACED ON MO SIDE k. NDSOI NOTES: 1. ALL TRUSSES LOCATED 1NITHIN 36' OF THE END OF THE R SECTION TO BE DOUBLED. 2. SEE OTHER DETAILS FOR TYPICAL ROOF FRAMING. 3. EACH TRUSS IN END ZONE AREAS ARE REQUIRED TO BE FASTENED PER AD—PR-7002. TYP. OUTLOOKER FASTENING: FASTENERS: cummY: PFNEIRAmt .131 PD NAD. 5 1 1/f 15 GA.. STAPLE 8 1' #8 SCREW 2 1' (INCL TIP) d1RDM FA51ENIX MAY E NSIAUED VANDZONE III FROM 10P OW DON F PElEMI N ALL EXPOSURES IS MEAD, (110 MPH) 20 PSF ROOF 10 PSF D.L. C-RC-197.01-197.02 •John C. Doeden, *Pk K2 Enginieiing; Inc. DAPIA APPROVAL• APPROVED BY Feb 05,2008 000 14rNC. FEDERAL KANUFACTURED HOME CDNSMCnON AND SAFETY STANDARDS JACOBSEN HOMES N0T1C0 TIESE �ccF1cAT+olu ANa DRA1DiGS ARE ORtQULL. FBDPMMY. AND CDNFuuffft DRAW �' O.A. DATE 1-29-08• REv tErIER DRAWING VM EAFEI P.O. BOX 366 wmlws /47 �" OF wTDws � r� so MUMS BE FRGYOEED END ZONE RAFTER/OVERHANG ASSEMBLY sAFM HARBOR. FLORIDA U695 F I rw im sroDFr FnE= MD RM K DRAWNG NUMBER PHONE (727) 726-1138 WT ONFOMMl IUD SEDIET IRON OnM AD—PR-7003 22 ON SITE PITCHED ROOF DECKING INSTALLATION TYP. ROOF FRAMING 16" ON CENTER TRIPLE WOE CENTER SECTION PEAK _ SITE INSTALLED DECKING ON PITM NO BLOCKING REQUIRED TRuss SECnoN lE REMAINDER of AT CONTINUOUS PANEL BOTH OUTSIDE SECTIONS (2 FULL ROWS OF SHEATHINO) SEAMS BETWEEN TRUSSES • SEE OTHER DETAILS TO SECURE TRIPLE WOE MARRIAGE LINE SITE INSTALLED PITCHED TRUSSES MIN. WIDTH PER SHEATHING REQUIREMENT APA RATED ROOF DECKING (OR EQUAL) '.INSTALLED DECKING TO HERE vs WNDZONE 81 ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L NOTES: ENGR FR APAWu DMA APPROVAL 1. 1/e MAXIMUM GAP AND 1/16" MINIMUM GAP BETWEEN DECKING PERPENDICULAR AND PARALLEL TO TRUSSES. APPROVED BY 2. ROOF DECKING MATERIAL TO BE 7/16" APA RATED ROOF (24/0 %I W Revised SPAN RATED) DECKING (EQUAL OR BETTER). ,p ri (',, O� n. F? N 14 Oct 29,2007 3. OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THE K2 !iIC. II �. SAME DECKING PATTERN. I V FEDERALKftNUFACrURED MDoE 4. FASTEN DECKING TO ROOF FRAMING WTH 7/16 X 1 1/2- X 15 CONSTR11CT10NAND SAFEWSTANDARDS GA. STAPLES AT 3' O/C EDGES AND FIELD JACOBSEN HOMES Dim o ot:w� er. O.A. oAtE 10-24-07 M. LM' P.O. 36e 1F m mwa m �"C� PITCHED SUCHMW,� Or SITE ROOF DECKING INST. R. SAFETY HAR60R, FLORioA 34695 PHONE (727) 726-1138 FMW FOR VOW F111l06t5 NO FNS1 It WT CMF MM No SM RV OrdM OR NUS WNG AD-PR-7004 23 SITE INSTALLED PITCHED ROOF VENTING TYP. 50 SQ. IN. ROOF VENTS (SEE AD—PR-7006 FOR QUANTITIES) TYP. 100 SO. IN. CUTOUTS FOR - VENTILATION OF ROOF SECTION (SEE AD—PR-7006 FOR QUANTITIES) FLAT CENTER SECTION OF ROOF INSTALLED AT MANUFACTURER TYP. ROOF INSULATION CEILING PANEL CENTER SECTION (FLAT TRUSS) MARRIAGE WALLS MARRIAGE WALLS FLAT CENTER SECTION NOTES: SITE INSTALLED CENTER SECTION OF ROOF APPROVED BY Revised ON Oct 25,2007 owoINC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS � JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE „� �EaF,�„noNs „No DRAWINGS ARE OR RMAL. PROPRIETARY, AND CDNFOENTA CTUHINO ARE! PROVIDED INC- �, ruTrRu�s � PRo>A�D To � ISUMS OF JACOMATERIALS REOW FOR SIECIRC RWRPOSES AND WbT SE KEPT CO VIDENTIAL RD SECRET FROM OTHERS DRAWN BY: O.A. DATE: 10-24-07 REV. LETTER n A DRAWING TITLE: SITE INSTALLED PITCHED ROOF VENTS I)RAyWNG NUmM;; AD-PR-7005 - 24 ROOF VENTING sg I I I I 3 W nv too So. K alom FOR V61l1A110f or ROOF SECTION is (SEE GURT fOR KOlJRXNT5) 100 SQ. IN CUTOUT VENT HOLES R N SECTION REQUIRED 1N FLAT ROOF (1607 X SECTION LENGIR CUTOUT HOLES 0 TO 1S'-C 1 154' TO 31'-3' 2 31'-3' TO 46 -W 3 46-Ur TO 6 -6 4 62-6 TO -0 5 I I MARRIAGE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED MARRIAGE WALLS LOW VENT LOW VENT •50 s0. IN. VENTS REOUIRED `3 H1GH VENT IN SITE INSTAllyn TRUSS SECTION c ; -A W-�_ _ CENTER LINE OF CENTER SECTION Inn = 9im toctl! "m KN1 too wa 10 3r-T t10K mm Y- 10 tf - 1 ow 4w-w to a-f, : I 1 EA sQ 67 to 6ir-ir i 1 2 E& 9K dt N1 NX 1D OKtM4 KRIS 1.1N -- TYF'. 50 S0. K ROOF VENTS �- LOW VENT (SEE CHART FOR REOUIREMENTS) LOW VENT , MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. DAM APPROVAL: AF PROVED BY CJUN 10 ? INC..' LMANUFAMFIED HOME ETY STANOAROS DRAwm BY: DAZE NLr. U I RIC li JACOBSEN HOMES mg ski" mo mA-m R.R. 0�-22-oa II � or JACCIM M DRAWING T1TL� ROOF VENTING P.O. BOX 368 0t WM lufpMS AK FMW TO lK _ SAFETY HARBOR FLORIDA 34695 tNxwm FOt 9W PAUM MO qbT K DRAW" NUMBER: I PHONE (727) 726-1138 ttVT cOtF1pO aK me SEM 11011 UNIX AU - PR- %Q06 I I MARRIAGE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED MARRIAGE WALLS LOW VENT LOW VENT •50 s0. IN. VENTS REOUIRED `3 H1GH VENT IN SITE INSTAllyn TRUSS SECTION c ; -A W-�_ _ CENTER LINE OF CENTER SECTION Inn = 9im toctl! "m KN1 too wa 10 3r-T t10K mm Y- 10 tf - 1 ow 4w-w to a-f, : I 1 EA sQ 67 to 6ir-ir i 1 2 E& 9K dt N1 NX 1D OKtM4 KRIS 1.1N -- TYF'. 50 S0. K ROOF VENTS �- LOW VENT (SEE CHART FOR REOUIREMENTS) LOW VENT , MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. DAM APPROVAL: AF PROVED BY CJUN 10 ? INC..' LMANUFAMFIED HOME ETY STANOAROS DRAwm BY: DAZE NLr. U I RIC li JACOBSEN HOMES mg ski" mo mA-m R.R. 0�-22-oa II � or JACCIM M DRAWING T1TL� ROOF VENTING P.O. BOX 368 0t WM lufpMS AK FMW TO lK _ SAFETY HARBOR FLORIDA 34695 tNxwm FOt 9W PAUM MO qbT K DRAW" NUMBER: I PHONE (727) 726-1138 ttVT cOtF1pO aK me SEM 11011 UNIX AU - PR- %Q06 dt N1 NX 1D OKtM4 KRIS 1.1N -- TYF'. 50 S0. K ROOF VENTS �- LOW VENT (SEE CHART FOR REOUIREMENTS) LOW VENT , MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. DAM APPROVAL: AF PROVED BY CJUN 10 ? INC..' LMANUFAMFIED HOME ETY STANOAROS DRAwm BY: DAZE NLr. U I RIC li JACOBSEN HOMES mg ski" mo mA-m R.R. 0�-22-oa II � or JACCIM M DRAWING T1TL� ROOF VENTING P.O. BOX 368 0t WM lufpMS AK FMW TO lK _ SAFETY HARBOR FLORIDA 34695 tNxwm FOt 9W PAUM MO qbT K DRAW" NUMBER: I PHONE (727) 726-1138 ttVT cOtF1pO aK me SEM 11011 UNIX AU - PR- %Q06 PITCHED ROOF EXTENDED VENTS SITE INSTALLED VENT CAP OR SOLAR TUBE VENT car (OR SOLAR SITE INSTALLED FLEX DUCT SITE INSTALLED VENT CAP (SEE DETAIL W) \ / SITSECTIONINSTALLED OF ROOF CENTER �— EXTEND FLEX DUCT 3' ABOVE RAFTER SHEATHING FLEX DUCT (FACTORY INSTALLED) FACTORY INSTALLED SHEATHING — FACTORY INSTALLED CENTER EXTEND PIPE 3' ABOVE SHEATHING SECTION OF ROOF PLUMBING VENT (FACTORY INSTALLED) LTYP. CONNECTION TO VENT FAN. SOLAR TUBE. OR EXTEND TO RANGE HOOD MARRIAGE WALLS CEILING PANEL SITE INSTALLED PLUMBING VENT PPE /(Ex IEND 3- ABOVE ROOF) (SEE DETAIL -B-) MARRIAGE WALLS FACTORY INSTALLED FLAT CENTER SECTION XHAUST DUCT SPLIT 4ND FASTENED TO ROOF )ECKING OR BACKER VITH MIN. 4— 8D NAILS N LIEU OF FASTENING )UCT TO VENT CAP. SITE INSTALLED FLEX DUCT _y SHEET METAL SCREW 0-*—FLEX DUCT (FACTORY INSTALLED) NOTE: EXHAUST DUCT (FLEX DUCT OR RIGID) SECURED WITH 1 SHEET METAL SCREW MINIMUM AND ALUMINUM TAPE TO SEAL AROUND DUCT AFTER SCREW IS IN PLACE. DETAIL 'A' NOTES: 1. FOR VENTS NOT SHOWN INSTALL PER MANUFACTURERS SPECIFICATIONS. Z SEE OTHER DETAILS FOR ROOF FLASHING INSTALLATION. 3. EXHAUST DUCT MAY BE RUN THROUGH EITHER A SOUARE OR ROUND HOLE CUT N ROOF DECKING. 4. RANGE AND BATH/AIR DUALITY FLEX DUCTS TO BE SPLICED WITH ALUMINUM TAPE AS SHOWN N THE DETAIL ABOVE. 5. SECURE SITE INSTALLED PLUMBING VENT PIPE INTO COUPLER WITH APPROVED GLUE. PLUMBING VENT ROOF FLASHING (SITE INSTALLED) —VENT PIPE (SITE INSTALLED) --COUPLER (SITE INSTALLED) VENT PIPE (FACTORY INSTALLED) DETAIL ' B' DAPIA APPRDVAL APP OVED BY JUN . leN INC. FEDERAL AANUFACTuRED HOME rnue'rol IlInN AND SAFETY STANDARDS oNOTICE DRAWN BY: JACOBSEN HOMES DATE O1-23-04 REV. LETTER: THESE �EonGITDNs AID w„I.acs ARE R.R. ORICKAL PROPRIETARY. AND CCIPRIOENUAL DRAWING TITLE: MATERIALS OF 44000SEN NAKFACTIR NG P.O. Box 368 Nt SUCN MATERIALS ARE FR0Y0ED iD THE PITCHED ROOF EXTENDED VENTS SAFETY HARBOR. FLORIDA 34695 KOW FR SPECI RiIPM NO EST K DRAWING NUMBER: ` PHONE (727) 726-1138 _lVT DONNgEMIAL NO SECRET RIOM DIM AD—PR-7007 26 SITE INSTALLED SHINGLE AND UNDERLAYMENT 150 FELT TO HAVE A 6' MIN. OVERLAP AND A MIN. 6' WIDTH OF ROOF CEMENT THIS ALSO APPLIES TO ENDLAP SEAMS. h FIELD INSTALLED 15J FELT MIN. INSTALLED OVER THE FACTORY INSTALLED UNDERLAYMENT NTH A 6' ION. OVERLAP AND A MIN. 6' W11DTH OF ROOF CEMENT. 15/ FELT ALSO CEMENTED WITH A 6' 1WDTH AROUND ALL PENETRATIONS OF THE UNDERLAYMENT AND PERIMETER OF ROOF. 1 I FIELD INSTALLED ROOF SHEATHING (TYP.) I I 6' VADTH OF ROOF CEMENT WHEN { OPTIONAL 15j FELT IS INSTALLED. 1 } I OPTIONAL LAYER OF 151 FELT I I LWI i I i I I I 1 ' ONE-PIECE SHWE UNDERLAYMENT ROOF SWARM (TWP.) THIS ROW OF SHINGLES TO BE FIELD INSTALLED AFTER THE UNDERLAYMENT HAS BEEN INSTALLED. THE LAST COURSE OF FACTORY INSTALLED SHINGLES TO LEAVE A MINIMUM OF 6' FROM THE TOP OF THE SHINGLE TO THE EDGE OF THE FACTORY INSTALLED DE"G FOR UNDERLAYMENT OVER LAP OF 6' MINIMUM. 1 /2' TO FASTENING Djj, NOTES: UW.VWZN ArrKUYAL' 1. CEMENTING OF OPTIONAL 15/ FELT IS NOT REQUIRED IN ANY AREA EXCEPT WHERE NOTED. 2. FASTENING OF OPTIONAL 15/ FELT IS NOT REQUIRED. (FASTENERS APPLIED Uub. ARE JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.)tl �g�� 3. SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS KZ Eng r1�Cifli-1g, Im- ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED. VANDZONE III (110 MPH) ALL EXPOSURES OVED BY rlIRevised Oct 29,2007 NC. MANUFACTURED HOME CTpN AND SAFETY STANDARDS JACOBSEN HOMES >� >� AM MAU=AN `"`"'N n' O.A. °"'L 10-24-07 "`" `L"°" Mon P.O. P.O. BOX oR1URPA. rmumIETANY: AM Oumpmun L WMU S W 4 CO8SET1 WMi'ACRM DRAINING WILL- NC SIm MATEmAS ARE PROM To Ut SITE INSTALLED SHINGLE AND Alf DFRLAYiBNT . SAFETY HARBOR. 1l OPoDA 3�695 FLORIDA RIMENT FTR SPBW W 00 A10 IMST DRAWING NUMBER rH' PHONE (813) 726-1138 KM onaoB W MO I= IRON ZKM AD—PR-7008 21 TYPICAL FLASHING INSTALLATION ROOFING TAR UNDER NAILING FLANGE AT ALL FASTENERS TYPICAL SHINGLE ROOF ROOFING TAR APPLIED OVER i TYPICAL FIELD INSTALLED RAFTER FASTENERS AND UNDER ALL SHINGLES OVERLAPPING THE ROOF FLASHING. AI N OR51 113' X MINIMUM NAILS MAY OPTIONAL SHINGLES MAY BE APPUED TO BE USED IN LIEU OF STAPLES FOR FASTENING FLASHING TO ROOF. COVER ANY ROOF VENT FLANGE BY SECURING THE SHINGLE TO THE FLANGE AREA MATH ROOF- ING MASTIC (TAR). OPT. SOLAR TUBE INSTALLATION TYPICAL SHINGLE ROOF i SOLAR TUBE DOME, MATH NAILER FLANGE, SECURED TO ROOF, ON TOP OF UNDERLAYMENT, AND TOP OF FLANGE UNDER SHINGLES. WITH BOTTOM OF FLANGE OVER SHINGLES (BOTTOM FLANGE MAY BE COVER WITH SHINGLE TABS SECURED WITH AN APPROVED CAULK). TUBE SUPPLIED BY SOLAR TUBE MAN. NOTES: DAPIA APPROVAL- 1. ROOF FLANGE FASTENED TO SHINGLE ROOF WITH MIN. 1' X 1" X 16 GA. APPROVED BY STAPLES 6" O.C. (SHINGLES APPLIED UNDER LOWER END OF FLANGE). IFEDEALANUFACTURED INC. HOME CON RUC1ION AND SAFETY STANDAROS JACOBSEN HOMES NO6 AND >KS< ons SQEOFN:AnAND ORAIVN(iS ARE DRAIN BY: M.T. DATE 02-04-04 REV LE1iER DRAWING TILE. OOGNA . IART. AND CowMTm „ P.O. BOX 368 YATDUALS OFJACCOSEM YANWACTUbN' W- RXH YAWRIALS ARE PROVIDED TO THE TYP, FLASHING INSTALLATION SAFETY HARBOR, FLORIDA 34695 KOMI FOR VOW PORP0513 NO W6T K DRAWING NUYBER: PHONE (813) 726-1138 XM CDfVMUL Ago SEMI rKm ONIX AD-PR-7009 28 ADDENDUM GENERAL 'NOTES / TIE-DOWINS NOTES: 1. FRAME TIE -DOWNS SHALL BE INSTALLED TO PROPERLY SECURE THE HOME. 2. VERTICAL TIE -DOWNS ARE REOUIRED IN ADDITION TO THE FRAME TIE -DOWNS. I VERTICAL TIES MAY BE SECURED TO THE SAME GROUND ANCHOR AS THE FRAME TIE -DO Mil MEN A DOUBLE HEADED ANCHOR IS USED AND IS CAPABLE OF RESISTING THE COMBINED LOADING. IMI N AIiCHORS ARE NOT INSTALLED AT THE ANGLE(S) SPECIFIED IN THE TABLE(S), A STABILIZER PLATE MUST BE ;NSTALLIT IN ACCORDANCE WITH THE ANCHOR MANUFACTURER'S INSTRUCTIONS. 4. FRAME TIE -DOWNS AND ANCHORS ARE NOT SUPPLIED BY JACOBSEN HOMES (TO BE Sl F ul) BY OTHERS). S VERTICAL TIE STRAPS MAY BE SUPPLIED BY JACOBSEN HOMES OR ANCHOR BRACKET MAY BE INSTALLED BY JACOBSEN HONES FOR ATTACHMENT OF VERTICAL TIE STRAPS, IN EITHER CASE ALL ANCHORS AND END TREATMENTS ARE TO BE SUPPLIED BY OTHERS. 6. ALL GROUND ANCHORS AND FRAME TIES SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. GROUND ANCHORS AND FRAME TIES ARE NOT TO EXTEND BEYOND THE DIERIOR WALL OF THE UNIT. 7. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER SHALL BE PROTECTED WITH A MIN. OF 0.30 OZ OF ZINC COATING PER SQUARE FOOT OF STEEL 8. DESIGN BASED ON 95 1/2' I -BEAM SPACING AND A MAXIMUM SIDEWALL HEIGHT OF 8'-0• (82' I -BEAM SPACING IS ACCEPTABLE FOR 10' WIDE SECTIONS OF MULTI -WIDE UNITS W/ 9T SIDEWALL HEIGHT ONLY). 9. LONGITUDINAL TIES SHALL BE INSTALLED ON THE INSIDE OF EACH I -BEAM AT THE CRGSS413ABER LOCATIONS OR PER ALTERNATE DETAILS IN ACCORDANCE WITH THE SPACING TABLES AND NOTES 4, 6, 7 AND 16. 10. FRAME %-DOWNS SHALL BE 'WRAPPED' AROUND THE MAIN I -BEAM (AS SHOWN ON TIP. CROSS-SECTION DETAILS) AND SHALL COME OFF THE TOP FLANGE OF THE I -BEAM NTH AN APPROVED BUCKLE OR LOOP. 11. ANCHORS SHOULD BE CERTIFIED FOR THESE CONDITIONS BY A PROFESSIONAL ENGINEER ARCHITECT OR A NATIONALLY RECOGNIZED TESTING LABORATORY AS TO THEIR RESISTANCE BASED ON THE INSTALLED ANGLE OF THE DIAGONAL TIE AND/OR VERTICAL LOADING AND ANGLE OF ANCHOR INSTALLATION M,'D TYPE OF SOIL IN WHICH TIC ANCHOR IS TO BE INSTALLED. 12. GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND BE AT LEAST 12' ABOVE THE WATER TABLE. 13. GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILIZER PLATES.SHOULD BE INSTALLED TO PROVIDE ADDED RESISTANCE TO OVERTURNING OR SLIDING FORCES. 14. 'ANCHORING EQUIPMENT SHOULD BE BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WITH TESTING PROCEDURES IN ASTM STANDARD SPECIFICATION D3593-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS. 15. ALL GROUND ANCHORS TO BE RATED FOR LOAD LISTED IN TABLES, TIMES 1.5 SAFETY FACTOR OR AN ULTIMATE LOAD OF 47251 (31501 DESIGN LOAD), WHICHEVER IS GREATER VALUES IN THE TABLES ARE DESIGN LOAD VALUES. 16. A MAMMUM OF TWO LONGITUDINAL TIE -DOWN STRAPS MAY BE INSTALLED AT A SINGLE CROSS -MEMBER LOCATION. IF MORE THAN TWO LONGITUDINAL TIE -DOWNS ARE REQUIRED (SEE APPROPRIATE SPACING TABLES) ADDITIONAL CROSS - MEMBERS MUST BE USED FOR ATTACHMENT OF STRAP(S) (OR SEE OTHER DETAILS FOR ALTERNATE STRAP ATTACHMENT). 17. LONGITUDINAL TIE -DOWN STRAP(S) MAY BE INSTALLED AT AN ANGLE NOT PERPENDICULAR TO THE CROSS -MEMBER 10 WHICH IT IS ATTACHED (SEE NOTE 16) IF REQUIRED TO MISS PIER LOCATIONS OR OTHER OBSTRUCTION(S). 18. ALL FIGURES (DETAILS) SHOWN IN THIS SECTION ARE TYPICALS ONLY. REFER TO THE APPROPRIATE TABLES FOR THE REQUIRED NUMBER, SPACING AND/OR SPECS OF SPECIFIC TIE-D01NNS AND ANCHORS REQUIRED. 19. SEE OTHER DETAILS IN THE SET-UP MANUAL AND ADDENDUM FOR BLOCKNG REQU:REAENTS. AL BLOCKING DETAILS CONTAINED WITHIN THIS MANUAL ARE APPLICABLE FOR AL ZONES AND ALL EXPOSURES NOTES: ENGINEER REM I'"••'•#A/ DAPIA APPROVAL' •�` O?.�,\STE.9 cc' ROVED BY THESE NOTES AND DETAILS ARE APPLICABLE ��•q,No. FOR WIND ZONE II AND/OR WIND ZONE III. THEY — ENE8703571 .JUN T 510 ARE ALSO APPLICABLE TO BOTH EXPOSURE 'C' .� AND EXPOSURE V. SEE APPROPRIATE TABLES _ FOR SPECIFIC INFORMATION ON EACH. j INC NOTICE ��/q/ o DATE: REV. LETTER: JACOBSEN HOMES " II1III1LL C.L.Y. 5-19-95 Case sPiCN1 KTAR Am tx cm ARE araaNAl. PROPiCETART, NiD CPNttoonla DRAN'WC TITLE: P.O. BOX 368 NATRUtS OF JACOMN YNATACAMC TD-GENERAL NOTES SAFETY HARBOR, FLORiDA 34695 W_ sro+ MATERIALS ARE PRO%= TO THE aECPoa FOR SKCM PJWM AM WSt K DRAWING NUUSER: PHONE (813) 726-1138 ON MWWTK NO SECRET TROY MYS AD—TD-0001 29 ADDENDUM NORMAL TIE-DOIVN SPACING TABLES ZONE II & III/EXP. C & D 1 F+, V �120'-0' 1 LONGITUDINAL TIE -DOWN SPACING TABLE MIN FLOOR WIDTH WIND ZONE II Y:N.OTY. ANCHOR ER gA. END OF ANGLE EA. YIN. B WIND ZONE III MIN.OTY. ANCHOR EA. END IAN GLE EA SECTION u1H. B 2 36' 2 45' 24'-0' 2 46' 2 60' 25'-4' 2 50' 3 38' 26'-8' 2 54' 3 41' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN FLOOR WIDTH MAX EAVE OVERHANG WIND ZONE H WIND ZONE III SPACING DL HEAD LOAD ANCHOR ANGLE SPACING DEL. HEAD LOAD ANCHOR ANGLE 20'-0' 12' 12' 12' 12' 8'-0, B'-0' B'-0' 5_0• 31501 3150# 3150# 31501 40'-50' 40'-50' 40'-50' 40'-50' 6'-8' 6'-8' 6'-8' 6'-8' 3150# 3150# 3150# 31501 40'-50' 40'-50' 40'-50' 40'-50' 24'-0' 254 26'-8' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH WIND ZONE II uIN.OTY. ANCHOR EA. END IO ANGLE FA SECTION YIH. 6 WIND ZONE III OR MIN.OTY. No EA. END IO ANGLE EA SECTION YIN. 6 20'-0' 2 50' 2 68' 24'-0• 2 70' 3 50' 3 45' EJ:460' 3 45' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE WIND ZONE H1 MIN. MAX. WIND ZONE 11 FLOOR EAVE SPACING G Da-HUDANCHOR ANGLE SPACING COL. HEAD ANCHOR ANGLE WIDTH OVERHANG LOAD LOAD 20'-0' 12' 5'-4' 31501 40'-45' 4'-0' 31501 40'-50' 24'-0' 12' 5'_4• 3150# 40'-50' 4'-0' 3150# 40'-50' 25'-4' 12' 5-4- 31501 40'-50' 4'-0' 31501 40'-50' 12' 5'-4' 31501 40'-50' %w %III)ITT '-0' 31501 40'-50' ENGINEER O DAPIA APPROVAL: �G NOTES: �� E • .���Q•\STR •••t4' �'� 1. SEE AD-TT_0001 FOR ADDITIONAL REOUIREMENTS. �� �.:Q� N.. F�.�i �� PPROVED BYE 2. SEE AD-M-Do11 FOR MAXIMUM PIER HEIGHTS REOUIRED FOR THE LOADS = ENE8 5 TABULATED ABOVE. ;,moo• �� �`� ►Exnuwmr�nu+ED�a�L INC. �. F�; ••. O I A+ . • ��� .� CcnsT� Nos+�m sTT+cMCT+ NOTICE J R4PN+D •. c.L.Y. DATE: 5-30-95 REV. LETTER: JACOBS EN HOMES THESE SPECTfTCATIOHS AND DRAVANGS ARE DRONAL. PROPRIETARY. AND COHnoENT1A1 DRAWNG TITTF MATERIALS OF JACOBSEN MMUFACTANG NORM. SPACING TABLES P.O. BOX 368 W_ SUCH MATERULS ARE PROMDfD TO THE SAFETY HARBOR. FLORIDA 34695 REOPINT rOR SPECSC KFMSES AND IGAI BE DRAWING NUMBER AD—TO-0010 PHONE (813) 726-1138 IVT CONiMTIAL AND SEGRET TRCM OIHLRS. 30 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIF-DOWN SPACINGS MAX PER AO-TD-0010 TABLE PER AD-10-0010 IMIll nX W-IU-WIU Iw&L rtx w-m-my lmxL rr .w-.v 1 .. — TYPICAL CROSS SECTION SHOWING TIEDOWNS FIGURE 1.0 SEE FIGURE 2.0 FOR ALTERNATE TIE-DOW MMOD FIGURE 1.1 SEE FIGURE 5.0 FOR ALTERNATE TIE-WU R .... SEE NOTE 5 FOR MASIM HDGHT ma NOTES: EHONEER`R\ovA� LQ�Oii''�,� .Etggy.(i[CW+1yE-B�/ il7VVCU I 1. SEE AD-TD-0D10 FOR SPACING TABLES.`C;�`'�G�c�TE��OFA_ Q No. 2 SEE AD-TD-0010 FOR QUANITY OF LONCITUDIAL TIE -DOWN STRAPS REQUIRED. ENE8703571 �. , 3. SEE OTHER DETAILS FOR BLOGONG (PIER) QUANTITY AND OTHER REWREIIAENTS. _ IA I v � 4. SEE AD-TD-0001 FOR ADDITIONAL REQUfREMENTS. 5. ZONE 2/EPOSURE V: 60" IIAXMUM NEWT - :.. $ PAt�Acr Mwwwo CFONAIDOAIiT►QIMa1R ZONE 2/EVMRE V: 44' NAXBIUM HEIGHT ��i��iP• REF. CALCS ZONE 3/EXPOSURE V: 40' MA)Wil HEIGHT ZONE 3/E) POSURE V: 36" MAXWIA HEIGHT IK •'���`� �i�4�Fs+S�Q • . • • • • �� ����,` JACOBSEN HOMES N0710E "yjOlAYp11 THESE SPECIFXATRINS AND DRAMINGS ARE C.E.Y. DATE 3-27-95 REV. LETTTR: OFOGNAL. PROP@ETANY. AND CONFIDENTIAL MATERIALS OF JACOBSEN MANLIFACP"G DRAMANG TITLE: FIGURES 1.0 AND 1.1 P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 INC. SM MATERUALS ARE PRQHOED TO THE FEUPO T FOR SUM PU IM AND OW BE DRAMANG NUMBER - AD-TD-0011 PHONE (813) 726-1138 WT CONFUNU& Aw muo FROM Omm 32 ADDENDUM RECOMMENDED TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION cunwnie mr_MuuAI gwhN m FIGURE 1.0 eeeAp868ifaeepll�B�,� „E • 4 • No 4 _ .. • u, TYPICAL CROSS SECTION s,�°®ohs' • �' e MOWING iIEDOWNS 1rP. aDGR sr=7 w"m7 ®�sASBOfLAi-ti%Q0 SEE NOTE 5 RR Wl�lIIY NEL6tlf mm ma (SEE of is) mm ma (SEE Km a) FIGURE 1.1 (omm mm ON 95 l/f 1-wm CENtERs AID es• K was) NOTES: APPROVED BY 1. SEE AD-11)-0010.1 FOR SPACM TABLES ONOOPI 2- SEE AD-TD-Om0.1 FOR QUANP OF IANOflUDIAI. m-IXIVIN STRAPS REWIRED. nmis,2oo9 3. SEE OTHER DETPJLS FOR BLOCKING (PER) QUANTITY AND OTHER REWIRENENiS N C . 4. SEE AD-TD-ow FOR AmmoNAL REQuIRMENTS. FEDERAL MULFAC'RNED HOME CONSTR MON AND SAFETY STANDARD 5. ZX 2/E>DSURE V: 67' MAXM HOW ZONE 3/$VMRE 'C': 58' MAXIM HEIGHT REF. CKM 6. WIEN ANCHOR ANCLE SHDNN ON AD-ID-MO-1 CANNOT BE ACWEVED, GT0. 215.01 - 215.20 INSTALL AN APPROVED STABI M PLATE NOTlC>?` DRANRI W. DALE: KY. LETTER: �•T os—o4—os JACOBSEN HOMES n= wm=wA1" WMAL. pROP11&T0Y. AHD omamo MI. HAZE W OF dA0 M YANUFAC MIO DRAWING TIRE: FIGURES 1.0 AND 1.1 P.O. BOX 368 W. sm mimmu w pR wm.lo M SAFEHONFLORIDA85 A t ��� DRAgIIG MWEt AD-TD-0011.E E(81) PHONE 33 ADDENDUM ����s �1 3 NORMAL TIE -DOWN SPACING TABLES 1 �' ZONE 1I & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III FLOOR WIN. OTY. ANCHOR YIN. OTY. ANCHOR S �Q WIDTH EA. END OF ANGLE EA. DID OF ANGLE EA SECTION MIN. 6 EA. TCTICN MIN. B 12'-0' 2 43' 2 55' 13'-4' 2 50' 1 2 68' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING Da. HEAD LOAD ANCHOR ANGLE SPACING DOL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0* 6' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' IS-4' 6' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III . WIN. OTY. ANCHOR UK OTY. ANCHOR FLOOR WIDTH EA END OF N EA ENDANGLE O EA. SECTION WIN. a EA. SECTION WIN. e 12'-0' 2 64' 3 47' 12'-0' 3 31' 4 33' 13'-4' 3 1 2' 3 1 55' 4 30' 4 38' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WAND ZONE II WIND ZONE III SPACING DOL HEAD ANCHOR ANGLE SPACING DBL. HEAD ANCHOR ANGLE FLOUR EAVE WIDTH OVERHANG LOAD LOAD 12'-0' 6' 5-4' 31501 4T-45' 4'-0' 3150# 40'-50' 6' 5'-4' 3150z 40-50' 4'-0' 3150# 40'-50' NOTES ENQ;EER�_` Ooct��'''' DAPIA APPROVAL• I, SEE AD-TD-0001 FOR ADDITIONAL REQULRELENTs ,.� Q� • . G�grE CIF �,, APPROVED BY op 2. SEE AD-ID-0013 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE ENE8703571 - T 5 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR. ' *= ' Nil , N C 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR MOTHS WITH 95 1/2'(�'� ' STAT '= F Q.-? k, � wm�JAa�ww cas,�:+auosvtTTswoAl�o I -BEAM SPACING, 96' IIA10UUNI SIDEWALL HEIGHT AND 6' MA)DLIULI SIDE OVERHANG (6' OVET�WNC MAX EACH SIDE OF UNIT). •, `� ���'��•.�/O1aN '�\� ``�� JACOBSEN HOMES NOTICE: �UNt!INT THESE sKoFlGTIMS ANO DRAMINGS ARE //��yy,�� IH114A`¢ � C.L.Y. DAB' ' 5-30-95 REV. LETTER: P.O. BOX 368 HE ORDINAL PROPR7ElW AND CONrMTIAL MATERIALS OF JACOBSEN VAM1FACARNG PC 2)04 U),Xmks ARE FRONDED TO THE DRAANG TITLE: NORM. SPACING TABLES n R(813)F726�D1�3846. Ctcmwu. RPFonao� 'L—�\ DRAWNGNUMBER: PHONESAFETY AD-TD-0012 34 ADDENDUM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE -DOWN SYSTEM FIGURE 1.2 Sl% MUO 2.0 RR ALfMIN M-DOW EMOD mu ARCIE FIGURE 1.3 SM MURB 7.0 FOR ALTPl 13 TZ-1101R MMOD 1. SEE AD—TD-0012 FOR SPAONG TABLES AND NOTES 2. SEE AD-TD-0012 FOR OUANTY OF LONGITIIDIAL 71E-DOWN STRAPS REQUIRED. 3. SEE OTHER DETAILS FOR BLOCIONG (PIER) OUANTITY AND OTHER REQUIREMENTS 4. SEE AD-TD-0001 FOR ADDITIONAL REOUREMENTS. 5. ZONE 2/EIMIRE V: 30' MAXWM HEIGHT ' ZONE 2/EXPOSURE V: 48' MAXIMUM HEIGHT ZONE 3/EXPOSURE 'C': 28' MAXIMUM HEIGHT ZONE 3/EXPOSURE 'D': 60' MAXIMUM HEIGHT SEE NOTE 5 FOR WON HEX#1T C Do >pTE :���N No. 9F�F2 : _ CNCA7nlA71 1. ' STATa..OF DAPIA APPROVAL APPROVED BY0 0000r N 14 ,, JAPE i i INS, �uRwaYwuTAtuI®IaIE w�aiticronMowErcaMa1R NOMEv"'ifpw'UN LDR" #I%- C.L.Y. DATE 5-19-95 REv LETTER.JACOBSEN HOMES THESE SPEORG+,M AND ORAgMUN1, OFJONAL. PROPRIETARY. AND COiFSODRUIL DRAWING 71 FIGURES 1.2 AND 1.3 A P.O. BOX 368 MATOW OF'IACOEM MWACTIIRNG OIC. SUCH MAMMS ARE PWMM TO THE SAFETY HARBOR. FLORIDA 34695 REOPDR FOR 9M PUWMS AND KW BE DRAWING NUMBER: PHONE (813) 726-1138 IVT COKMTVL AND SST FRCP OTIF M AD-TD-0013 35 ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS FIGURE 2.0 SEE FIGURES 1.1 AND 1.3 FOR TYP. CROSS -SECTIONS) uuurrrr E+ . iPAOVAL.. ' �.� O s"T DAPIA APPROVALNOTES: 1. SEE AD-TD-0010 FOR SPACING TABLES. �: Q�' No. O '• APPROVED BY I SEE AD-TD-0010 FOR OUANITY OF LONCITUOIAL TIE-D0VM STRAPS REQUIRED. _ ;' ENC-8703571 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REQUIREMENTS _ �• - J "� 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. . � V I� (� 11 � %C'� '�ND1A� V���•�� ��' Fss1p f4DEIW �rwJACRf�H]E Otr61RGiaArosvtnsDlCAI= Al A� /I JACOBSEN HOMES THESE sPEanuNONCE: noNs AND oRAwNuz ARE DRAWN BY: C.L.Y. DATE: 5-19-95 REV. LETTER: DRAWING TITLE: FIGURE 2.0 P.O. BOX 368 ORICHNAL, PROPKIARY• AND CCHFIDENTIAL MATERIALS CF JACOBSEN MAMIFACTURINC „ SAFETY 695 MG SUCH WATEPMS APE PROMDED TO THE FWSPE a OUT 00 � 0 5 DRAWING NUMBER HONER(813) 72FLORIDA 38 CWT nk Hn AD- TD-0014 36 ADDENDUM ALTERNATE TIE-DOIM SYSTEM(S) ALTERNATE LONGITUDINAL TIE -DON INSTALLATION METHODS SIDE VIEW OF MAIN FRAME -DowN STRAP I s[t OTHER DETAILS IOR iIE-DOMN STRAP SPECIFICATIONS. APPnOYCD ANCHOR Wc.D_D TO MAIN 1-BEAM (SEE OTHER DETAILS SEE 0-TD-0200 FOR FOR WELOPM TO BE INSTALLED' RADUS CUP DCTA!LS AT ilk" FACTORY. (REWIRED THIS LOCATION). (YIN. 31501 WORKING (D:SIGN] LOAD AND 47251 ULTIMATE LOAD.) o° GROUND ANCHOR SEE OTHER DETALS FOR SIZE, ANGLE AND OTHER INSTALLATION NOTES. SOLJD HEADER (CROSSMEMBER) SIDE VIEW NOTES: 1. SEE AD-TD-0010 FOR SPACING TABLES. 2. SEE AD-TD-0010 FOR OUANITY OF LONGITUDIAL TIE -DOWN STRAPS RLWf,ED. I SEE OTHER DETAILS FOR BLOCKING (PER) QUANTITY AND OrHER ,TEOLLREMENTS. 4. SEE AD-TD-OD01 FOR ADDRANAL REOUIREIIENTS. FIG URE 2.1 X 3/4' • MUST BE LOCATED CUR INTO HEADERER WTHIN S' OF MAIN FOR STRAP TTACh71EHT. CHASES 1-BEAU. (fACTORT CUT) SEE AD-m-c2DO FOR RADIUS CLIP DciALS (REOU O THIS LOCATION). GROUND ANO,OR' SEE OTHER DETAILS FOR SIZE, AYCRE AND OVER MTALLA71ON ?�iJ..IiAJJJ� JJ+' Al hW AMOVAL %, J. Ica • .�r., mil_ �Trl7c:'.:1: �•_ 111111,1(ON AAJJn 111 its" mcHoR BRACKET AND TILE-DOVN DLNICES ARE CERTIFIED BY OTHERS FIGURE 2.2 ':A APPROVAL, NOMC4 ..-..... _.. C.L.Y. I ---- B-13-95 - - -- JACOBSEN HOLIES TrESE SaEOM0ONS AND CRAZhZ AU CMAL PRCPWAItT. AND CO&MMAL CRAWL IG RU �� P.O. Box 36e !fC id MOWED TO Or JACO6ZN WAMfACTW/ifr- FIGURES 2.1 & 2.2 M MAIMALS ATO IW SAFETY HARBOR, FLORIDA 34695 Iaa or ►oR srEonc PAwm Am mA7 E ORATING NUuBER: PHWIE (8I3) 726-1138 ail c MIAL Pm WAMT n= OH= /4G-M-0015 37 LONGITUDINAL STRAP ATTACHMENT TYPI0 W CLAMP, MANUFACURED BY ENGINEERING, PART 159011 tj« „w.urACTURER'S INSTRUCTIONS FOR COMPLETE INSTALLATION DETAILS) TYPICAL LONGITUDINAL ANCHOR STRAP (FIELD INSTALLED) NOTES: DAPIA APPROVAL I. SEE OTHER DETAILS FOR STRAP PROTECTION AT ALL SHARP CORNERS A PROVED BY 2. ALL -STRAPS TO BE TYPE 1, FINISH B, GRADE 1 STEEL STRAPPING, 1 1/4" WIDE AND 0.035 INCHES IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL 15 • m ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D 3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. I N C. FEDE AL MANUFACTURED HOME CON RUCTION AND SAFEfYSTANDARDS NOTICE7. DRAWN BY. DATE; REV. LETTER: 'JACOBSEN BIOMES THESE SPECHICATIONS ANDRAWINGS ARE M.T. 6-12-01 — ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: •„ P.O. BOX 368' MATERIALS OF JACOBSTN NANufACNRMIG LONGITUDINAL STRAP ATTACHMENT INC. SUCH MATEMX5 ARC PROMDED TO THE SAFETY HARBOR. FLORIDA 34695 RECIRINT FOI 94MIC PURFM AND wsT RE DRAINING NUMBER: PHONE (727) 726-1138 im CONFlDENRAL AND SEW TROY OTHERS. AD— TD-001 fi 38 ADDENDUM OFFSET UNIT TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D S�� S 1 � S• j LONGITUDINAL TIE -DOWN SPACING TABLE V MIN. WIND ZONE II FLOOR MIN. QTT. ANCHOR WIDTH EA END OF ANGLE EA SECTION MIL a 10'-0' 2 44' WIND ZONE III WE on EA. END OFANGIf EA gcT10N O1 1 2 56' 1 12'-0' 2 57' 3 42' 13'-4' 3 iI38 3 50' VERTICAL TIE-DO)VN / FRAME TIE -DON SPACING TABLE MAX. EAVE OVERHANG WIND ZONE II WIND ZONE III MIN. FLOOR WIDTH SPADNc Del HEAD �- tRJID ANCHOR ANGLE SPAaNc LOAD LOAD mm ANGLE 12" 4'-0' 31501 40'-50' 4'-0' 31501 40'-50' 12' 4'-0' 30MI 40'-50' 4'-0' 31501 40'-50' 12'-0" 12' 5'-3' 31501 40'-50' 4'-0' 3D00l 40'-50' IS-4' jLONGITUDINAL TIE -DOWN SPACING TABLE r MIN. FLOOR WIDTH 10'-0' WIND ZONE II Ma. CITY. man Ell ENDSEC IO AN. EA SECTION WIN. a 2 64' WIND ZONE III UK OTT. ANCHOR EA. END IO ANGLE fA gcT10N uDi e 3 46' �1 12'-0' 3 50 3 68 13'-4' 3 4 VERTICAL TIE -DOWN / FRAME TIE-DO)VN SPACING TABLE MIN. FLOOR WIDTH MAX. EAVE OVERHANG WIND ZONE II VA ZONE III SPAONG D oAD ANCHOR ANGLE °� SAD SPACING LOAD AND+DR ANGLE 10'-0" 12' 4'-0' 31509 40'-50' 2'-8' 31501 40'-50' 12'-0" 12" 4'-0' 31001 40'-50' 2'-8" 3150� 40'-50' 13'-4" 12" 4'-0' 3065g 40'-50' 2'-8' 30001 40'-50' NOTES: ENGI`P t✓V -" A A ifk(5Vt-:D BY 1. OFFSET SECTION WITH THE MARRIAGE LINE WALL EXTENDING BEYOND THE ENDWALL OF0 �G�S T +?C`� '• REVISED THE ADJACENT SECTION MUST BE TIED DOWN AT THE MARRIAGE UNE W ACCORDANCE • Q �" T - gip 0 9 1 Willi THE TABLES ABOVE THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE , h' ; .. BE TIED DOWN W ACCORDANCE WITH THE NORMAL SPACING TABLES (AD-TD-0010). INC. 2. SEE AD-TD-CIOOI FOR ADDITIONAL REOUIREMENTS. .p �: • %�} _ : • ` 11 MANUFACTURED HOME FED 3. SEE AD-M-0021 FOR MAXIMUM PIER HEIGHT REWIRED FOR THE LOADS TABULATED CO ' XAL STRUCTION AND SAFETY STAND ABOVE. s `- , NOTICE: ��lug11 EIS � DALE: REv.lffiER: J AC O BS EN HOMES THESE SPECIFICATIONS AND DRAW ICS ARE R.R. 8-27-96 OWONAL PROMETARV, AND 00e111OENTIAL DRAWING TIRE: MATERIALS of JACOM MAIUFACTURRIG OFFSET SPACING TABLES P.O. BOX 368 MC. SUOI MATERULS ARE PRONOM TO THE SAFETY HARBOR. FLORIDA 34695 REOPOIT FOR SPEOM PURPOSES MD "ll TN DRAWING NUMBER: AD-TD-0020 PHONE (813) 726-1138 VVI c01/wLq No SEOXT ERIII Onm �� 39 ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE —DOWN SPACINGS FIGURE 3.0 SEE FIGURE 4.0 FOR ALTERNATE TIE -DOYEN IIETNOD IYP. CROSS SECTION(S) SHOWING TIEDOWNS SEE NOTE 5 FOR M"ll H7GHT ANGLE ANGLE FIGURE 3.1 311 FIGURE 6.0 FOR ALTERNATE TIE -DOWN HETHOD [TARES ON AD-TD-0020 DO NDi APPLY TO WE STANDARD MULTI-YIDE SECTIONS CF THE UNIT -SEE NOTE 1, AD-TD-00 0.1 IMP. FLOOR SYSTM-7 III TV. CROSS-1 wm ANCHOR ANGLE ANOIOR ANGLE FIGURE 3.2 11.11180 ALTERNATE M-DOU METHOD NOTES: ENII` o „ �i,� DAPIA APPROVAL 1. SEE AD-TD-0020 FOR SPACING TABLES OFFSET SECTION ONLY). ���` O ' G\STF,Q '• F �� c No. Fa'.2 APPROV ED BY 2. SEE AD-TD-D020 FOR OUANITY OF LONGITUDIAL TIE -DOWN STRAPS REQUIRED. (OFFSET SECTION ONLY) ENE8703571 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND 01HER REQUIREMENTS. 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. [� 5. ZONE 2/EXPOSURE 'C': 44" MAXIMUM HEIGHT 9� / : �wAr�cnnra�►nE (�J ZONE 2/EXPOSURE :0': 24' MAXIMUM HEIGHT (32' 0 24' WIDE MIN.)ZONE 3/EXPOSURE C: 32 MA)OMUAI HEIGHT •'•��':•'\���� �MSihR7A71AUra5AF{ITSWpy� ZONE 3/EXPOSURE '0" 32' MAXIMUM f OGHT (44' 0 24' WIDE MIN.) �iszoAf L ��``"��� JACOBSEN HOMES NOTICE THEE SPECIFlCAnoNS AND DRAWINGS ARE DRAWN BY: C.L.Y. DATE 5-11— 95 REV. LETTER: P.O. BOX 368 ORIGINAL., PROPRIETARY, AND CONFlDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE.- FIG. J.O, 3.1 & 3.2 n �„� SAFE R(013) 7261D1384695 INC. SUCH MATERIALS ARE PRONDED TO THE Ct RRPOIFSM STM H DRAWING NUMBER: HONETY CFW� SECRET � o AD—TD-0021 I 40 ADDENDUM ALTERNATE OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) MOWING TIE -GOWN SPACINGS FIGURE 4.0 SEE FIGURES 3.1 AND 3.2 FOR TYP. CROSS-SECTION ..uuulluu,.. NOTES `Erz�APRROV4110L.'�i,��, DAPIA APPROVAL 1. SEE AD-TD-0020 FOR SPACM, TABLES (OFFSET SECTION ONLY). )O`(•,'���STERFC�F.L'�; APPROVED BY P No. O•'•, 2. SEE AD-TD-0020 FOR OUANITY OF LOTT 17WAL TIE -DOWN STRAPS REQOIRED. (OFFSET SECTION ONLY) _ NE8703571 JA 5 3. SEE OT}U DETAILS FOR BLOCC4O (PIER) QUANTITY AND OTHER REQUIREMENTS. _ • 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. TAT Q(• INC ": . •,F/�j rq � �.: ,1�W11u�tiK'l1/lD N7E ���; • /"QlAN •'�� �� cobl�,aaA10Y/STttT1A1L•Vt� �•.sip��Al Eh����•• JACOBSEN HOMES ANo Am DRAWN e1. ' DAB' ' TNESE SPEOFIGAT°s mAum C.L.Y. S-11-95 ■ P.O. BOX 368 OMONAL, PROP(E[TART. AIM CONlDEMT1AL MATIDO S OF JACOM MAMNACTUMNO DRAWING TIU- FIG. 4.D „ HA°'c �R. FLORIDA 31695 IH_ 27CH MATERLALS ARE PRWO) TO THESAFETY REWaT ►0t PErne PJMZ MD RM DE . DRAWING NIIMBER PHONE {8T3) 726-1138 PVT tWMLq NO SECIV 1101 OHM AD-TD-0022 41 ADDENDUM ALTERNATE UNIT TIE -DOWN SPACING TABLES C & D ZONE II & III/EXP. LONGITUDINAL TIE -DOWN SPACING TABLE rt MIN. VAND ZONE II WND ZONE III AIN. ANGLER YIN ANCHORLE r FLOOR D O [A. END AN. D O EA. END (fir ANGLE WIDTH IO � SECTION YIN. A EA. SECTION MIN. 0 2 36' 2 45' 24'-0' 2 46' 2 60' 25'-4' 2 50' 2 67' 26'-8' 2 55' 3 M. VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR EAVE SPACING D8L HEAD SPAONG D L HEAD ANGLER ANGLE ANCHOR ANGLE L- WIDTH OVERHANG LOAD - 4'-0' 36701 20' 4'-0' 3900# 20' 20'-0' 12' 4'-0' 37001 20' 4'-0' 39501 20' 24'-0' 12 6'-8' 40001 15' 4'-0' 39501 22' 25'-4' 12' 26'-8' 12' 6'-8' 39501 28' 4'-0' 3950# 22' LONGITUDINAL TIE -DOWN SPACING TABLE n MIN HIND ZONE II WIND ZONE III v FLOOR YIN. OTT. ANGLER EA. END OF ANGLE YIN. OTT EA. END OF ANCHOR PdDTH EA. SECTION YIN. A MIN. E1 SECTION YIN. A 20'-0' 2 50' NIA N/A �O 2 70' N/A N/A 3 42' N/A N/A N/A N/A N/A N/A VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR EAVE SPACING D& DDANCHOR ANGLEL HEAD SPACING OAS M0IOR ANGLE WIDTH OVERHANG LOAD N/A N/A N/A 20'-0' 12' 4'-0' 40001 20' N/A N/A N/A 24'-0' 12' 4'-0' 40001 24' N/A N/A N/A 254 12' 4'-0' 40001 26' N/A N/A N/A 26'-8� 12' 4'-0' 40DOI 27'.., �T�fI , NOTES: ENGI kit'APPR�AL DAPIA APPROVAL rl �� _ 1. SEE AD-TD-OD01 FOR ADDITIONAL REQUIREMENTS O .• n0. _ " 2 SEE AD-TD-0031 FOR MAXIMUM PIER HEIGHT REWIRED FOR THE LOADS TABULATED EHNE8703571 ABOVE: _ `\ — 3. 20 HIDES -82' MAXIMUM I -BEAM SPACING ONLY. 6�2`}7- (� 4. 4' MAXIMUM INSET TO ANCHOR HEADS SEE AD-TD-0031 ��i ` �� _..._.....v..:.. N017CE« ��TTIT TQR111 N DATE C.L.Y. REV. LETTER: 6-13-95 JACOBSEN HOMES iMESE SPEOF1CAl10N5 AND DRAMRS ARE OMONAL. PROPMETARY. AND CDNFMr'#L DRAWING TITLE: ALT. SPACING TABLES P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 MAKRIALS OF JACOBSEN YANUFACIURING INC SUCH MATERIALS ARE PRONDEO 70 THE REWDIT FOR PECTIC PIRPOSTS NO Ica' BEORAWING NUMBER: AD-TO-0030 PHONE.(813) 726-1138 ATPT CW Mnk AND SLQIET IM ODM 42 ALTERNATE TYPICAL CROSS SECTION SHOWING TIEDOWNS ADDENDUM TIE -DOWN SYSTEM(S)- SEE NOTE 4 FOR NA1m10Y HEIGHT 4- MAX FIGURE 5.0 m,J L SEE FIGURE 1.1 FOR RECOMMENDED M-DOTE WTHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING TO TIE-DOAN COh77GURATIOH A STYLE CREST PRODUCTS YODEL 57SH (TYPE 2), AUGER ANCHOR TITH A DESIGN [DAD (TOROG IAAD) RATING OF 4,000 POUNDS AND AN ULTIMATE TOAD RATING OF CODO POUNDS MUST BE USED. AN EQUIYD.ANT ANCHOR NEIsUG THE ABOVE SPECInCATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN LIEU OF THE STYLE CREST PRODUCES ANCHOR NOTES: I. SEE AD-TD-DDOI FOR ADDITIONAL P.EOUIREMENTS. 2. SEE OTHER DETAILS FOR BLOCKING (PIER) OUANTITY AND OTHER REOUIREMENTS. 3. FOR FIGURE 5.0 SEE ALTERNATE TE-DOWN SPACING TABLES (AD-TD-0030). 4. ZONE 2/EXPOSURE 'C': 31C MAXIMUM HEIGHT ZONE 2/EXPOSURE 'D': 27' MAXIMUu HEIGHT ZONE 3/EXPOSURE 'C': 30- MAXICUu HEIGHT ZONE 3/EXPOSURE 'D': THIS APPJCA71ON IS NOT APPLICABLE. THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE N ALL WIND ZONES AND IN BOTH EXPOSURE 'C' AND EXPOSURE *0'. HOWEVER. BY INSTALLNG THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD' I -BEAM THE MAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS. ....nuns..._ Cr 1ST•''•`,•'•`, No, 66 ENE870357T JACOBSEN HOMES NOTICE ••`IDEAL 1K`+E=EOFICAR NS AND DRAWINGS ARE . OiIONAL. PROPRIETARY; AND CONFIDENTLIL P.O. EOX 368 MATERIALS OF JACOBSEN MANNACTURING „ SAFETY HARBOR. FLORIDA 34695 PC SUCH NATEIEMS ARE PRONDED TO THE RLOW fOR SPECrIC PUNS AND UM N PHONE (813) 726-1138 IOPT CONFDOIHAL APO SECRET IRON OTHERS. ORAWN BY. C.L.Y. rsxl:• tom: ter= 6-13-95 FIG. 5.0 AD-TD-0031 43 �f ADDENDUM �g�s �`���f'p0 CEO ALT. OFFSET UNIT TIE -DOWN SPACING TABLES Q 6 ZONE II & III/EYP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN WIND ZONE II WIND ZONE III YP1. Ott• EA END OF EA SECTION ANCHOR AN MIN. a WIN. OTY. EA. END OF EA. gcncN ANCHOR ANGLE MIN. e _k `4 U1� FLOOR D� O 20'-0' N/A N/A N/A N/A 24'-0' 2 42' 2 53' > 25'-4' 2 45' 2 1 58' 26'-8' 2 48' 3 370 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBIL HEAD LOAD ANCHOR ANGLE SPACINGOBI. HEADNG LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0" 12' N/A N/A N/A N/A N/A N/A 24'-0" 12' 4'-0' 40001 20'-30' 4'-0' 40001 2T-30' 25-4' 12" 4'-0. 40001 20'-30' 4'-0' 4000# T 20-30' 26'-8' 12' 4'-0' 40001 20'-30' 4'-0' 4DO08 1 25'-30' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE it WIND ZONE III WIN. OTT. EA. ENO OF ANCHOR ANGLE YDI. CITY. EA. END OF ANCHOR ANGLE FLOOR O WIDTH EA SECTION YIN. B EA. SECTION WIN. B N/A N/A N/A N/A 24'-0' 2 60' 3 45' v�20'-0' �l 25'-4' 2 66' 3 48' 26'-8' 3 1 41' 3 52' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL HEAD ANCHOR ANGLE SPACING HEADNG LOAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD 20'-0' 12' N/A N/A N/A N/A N/A N/A 24'-0* 12' S-8' 40001 20'-30' 2'-8' 4000# 20'-30' 254 12' 4'—O' 40001 250-30' S-2' 4000 j 15t-30' 26'-8' 12' 4'-0' 40001 25'-30' S-2' 4000# 25'-30' NOTES: ENGINEER AD�Llyrurllrrll/l DAPIA APPROVAL: OF .��`� C. D�,''% ...... c0 '�• PPROVED BY 1. OFFSET SECTION MTN THE MARRIAGE LINE WALL EXTENDPIC BEYOND THE ENDWALL SECTION MUST BE TIED DOTM THE MARRIAGE IN ACCORDANCE ,•��N THE ADJACENT AT LINE 1ATH THE TABLES ABOVE. THE SIDEWAL SIDE AND THE ADJACENT SECTION(S) ARE TO : �:. Q� h0 O '. JUN 1 4 BE TIED DOWN IN ACCORDANCE VAIN THE ALT. SPACING TABLES (AD-TD-0030). E r�i I INC 2. SEE AD-1D-0001 FOR ADDITIONAL REOUREMENTS. �QT ' ST Ft`, -," 3. SEE AD-TI]-0033 FOR MAXIMUM PIER HEIGHT REQUIRED FOR THE LOADS TABULATED ABOVE i.� ��'. /• y.•' a� i JACOBSEN HOMES 'oliI j. THESE SPEC6TUTNio115 Am DRAWI6'�'II )m `aaa 1W C.L.Y. DATE: 5-30-95 REV. LETTER DRAMNG TITLE: ALT. SPACING TABLES ORONAL. PROPRIETARY. AND CCN(MTK MAMOALS OF JA)om mwACTLMG P.O. BOX 368 Opp SAFETY HARBOR, FLORIDA 34695 VY&ALS ARE NOMED TO THE rsmwi1 ro AspEGre Rllc' m APO WST K DRAMNG NUMBER: AD—TD-0032 PHONE (813) 726-1138 IVT MWMTUL AND SE04ET rK9 ones 44 1G►•rbN 15 �� SEE ��� � ADDENDUM 11,TAS ►tj�;R6Sof -'ALTERNATE Lai TIE -DOWN SYSTEM TYP. CROSS SMON(S) SHOWING TIEDOWNS "I mu FIGURE 6.0 SEE FIGURE 3.1 MR RECOMWENDED M-DOIIN METHOD SEE NOTE 5 FOR MA)0" ImRiT (TA B OF AD-TD-= W-M APPLY m THESE STAHMRD MAJT _VCE mcma OF THE U107 -SEE ROTE 1. AD-TD-00.121 M FLOOR STSTEII7 TYP. ARM ANU M04OR ANCIE FIGURE 6.1 SEE MURK 12 FOR RDCOMMENDED 77-DOIEN METHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS M-DOWN CONFIGURATION A STYLE CREST PRODUCTS YODEL 57SH ('TYPE 2)), AUGER ANCHOR TRH A DESIGN LOAD ((iORRING LOAD) RATDTG OF 4.000 PCUNDS AND AN ULTDIATE LOAD RATING OF 6,000 POUNDS MUST BE USED. AN EQ111VB.ART ANCHOR MEETING THE ABOVE SPEClPICATl011S MADE BY ANOTHER MANUFACTURER WAY BE USED IN LIEU OF THE STYLE CREST PRODUCTS ANCHOR. NOTES: THE ALTERNATE LIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE N I. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS ALL WJID ZONES AND N 607H EXPOSUM V AND EXPOSURE b', HOWEVER. BY INSTALL,NG THE FRAAE TIE -DOWN STRAPS AT THE 'OUTBOARD' 1-BEAM THE MAX 2. SEE OTHER DETAILS FOR BLDOONG (PIER) QUANTITY AND OTHER REQUIREMENTS. HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR 1HE 3. FOR FIGURE 6.0 SEE OFFSET UNIT TIE -DOWN SPACING TABLES (AD-TD-0020). RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS. 4. FOR FIGURE 6.1 SEE NORMAL TIE -DOWN SPACONG TABLES (AD-ID-DOIO). ENGINEER (ALSO SEE AD-M-0020 AiJ OAAA APPROVAL 5. ZONE 2/EXPOSURE 'V.- 32u AND HEIGHT �� `� 'C .... DO O'' 1; ZONE 2/EXPOSURE b'IOMU : 24' MAY HEIGHT . � •• G E9 ' �. PPROVED BY ZONE 31EVOSURE 'C': 24' YAXIWY HEIGHTQNo. � ' S � ZONE 3/EV.-lwosuRE 28' MAxnFUM HEIGHT E8710 3 NIP INC Vv JACOBSEN HOMES NOTICE a�► DATE: REV. LETTER THESE SPECOr-ATIOG AND DRANNIs ARE ' �"` C.L.Y. 5-30-95 m MORAL I'ROPRIETART, AND WOUR UAL DRAWING MTM P.O. BOX 368 MATTOZALS OF JACOBSEN MANUFAC7LRNC FIG. 6.0 6.1 SAFELY HARBOR FLORIDA 34695 , mG 5UW NATIOdA S AM PAONOED To THE dC RFCPI NT FOR SPECIFIC RJtPM No WSI BE DRAWING NUMBER: PHONE (813) 726-1138 10PT CON Mnk NO SEOV IRON omm AD—TD-0033 45' ADDENDUM Vol% ALTERNATE TIE -DOWN SPACING TABLES ZONE II & III/E_KP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. W'ND ZONE II WIND ZONE III MIN. Oly' ANCHOR uw OTT. ANaaR V FLOOR WIDTH E END OF ANGLE EA ENO OF ANGLE EA SECTION MIN. A EA SECTION MIN. B 12'-0' 2 43' 2 55' 13'-4' 2 50, 2 68' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING D�� ANCHOR ANGLE SPACING LOAD DB. HEAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0' 6' 4'-0' 37501 20' 4'-0" 39001 22' 13'-4- 6' 5-4' 38501 25' 5-4' 3960# 30' THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III YIN.OTY. EA ENO OF ANCHOR ANGLE YIN. OTT. EA END ANCHOR ANGLE FLOOR WIDTH EA gcTHON UK O EA. SECTION ulx. e 12'-0' 2 64' 3 47' 12'-0' 3 37' 4 33' 13'-4' 3 42' 3 55' 13'-4' 4 30' 4 38' VERTICAL TIE —DOWN / FRAME TIE' —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DO HEAD ANCHOR ANGLE SPACING D OHEw ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG Low 6' 4'4 39501 25' 2'-8' 39301 20' 13'-4' 6' 4'-0- 39601 25' 2'-8' 4000 30' THIS ALTERNATE APPLICATION REQi1IRES1114,,000 POUND ANCHORS NOTES ElNGNE�(i� `PR�L .OF^ �/�4 ` .........4✓ ''�i DAPIA APPROVAL 1. SEE AD-TD-0001 FOR ADDITIONAL REOLIMENTS ���: t�G�STE9F0 Z APPROVED BY 2. SEE AD-7D-0036 FOR MAD" PIER HEIGHTS REDUIRED FOR THE LOADS TABULATED ABOVE No. = .' ENE$703571 = 5 ap 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEINALL NOT FRONT OR REAR. � :•� ` I INC 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS WITH 95 1/2' y�O •'•. / 6 4 9 •��� '•� '�Xt` ' 0 �. •' PA mmg i>?6DL GI QIMO�LA{ITlv'[yn I -BEAM SPACING, 96- MA10MLW SIDEWALL HEIGHT AND 6- MAXIM M SIDE OVERHANG OVERHANG MAX EACH SIDE OF UNITS • (�\ ��• (6' JACOBSEN HOMES N079CE. 'FtN TmEsE VENS AND DR mm ARE CIACATW MONAL, PROPRIETARY. AND COT#MTIAL ��rn C.L.Y. DAIS 5-3D-95 REV. LETTER ! DRAWING TITLE: TABLES „ P.O. BOX 360 SAFETY HARBOR, FLORIDA 34695 AN MAIMALS OF JACO89N MITFACTURING NG SUCH MATERIALS ARE PROM= TO THE KoplENT Fat SPEC7IC PJKZ AND M15T a ALE. SPACING DRAWING NUMBER: AD—TD-0040 PHONE (813) 726-1138 IVT Nb1 WTTAL AND SEOV raw OTHERS. it C11 10ll� ADDENDUM ALTERNATE 00° E SYSTEM TYPICAL CROSS SECTION SHOWING TIEDOWNS MIME MOLE FIGURE 7.0 SEE FIGURE L3 FOR RECOM INNDED TIE-DOTN METHOD IMPORTANT NOTICE: SEE NOTE 4 FOR W=M HDMT THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS TIE-DDIN CONF IGUROON A ST1'!E CREST PRODUCTS YODEL 573H (TYPE 2� AUGER ANCHOR TI H A DESIGN IDAD (TORT= LO D) RATING OF 4,000 POUNDS AND AN ULTIMATE IDAD RATING OF 6,000 POUNDS MUST BE USED. AN EQUIYI,w ANCHOR MEETING THE IBOVE SPECDiC mN5 WE BY ANOTHER MANUFACTURER MAY BE USED IN IZU OF THIN STYLE CREST PRODUCTS ANCHOR. NOTES. THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN 1. SEE AD-ID-ODDI FOR ADDITIONAL REQUIREMENTS ALL WIND ZONES AND IN BOTH EXPOSURE V AND EXPOSURE V, HOWEVER, BY INSTALLING THE FRAME TIE -DOWN 57RAPS AT THE 'OUTBOARD' 1-BEAM THE MAX 2. SEE 07HER DETAILS FOR BLOCIONG (PIER) OUANTITY AND OTHER .REQUIREMENTS. HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 7.0 SEE ALTERNATE TIE -DOWN SPACING TABLES (AD-7D-0035). RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS ZONE 2/EXPOSURE 'C': 38' MAXIMUM HEIGHT 4. ENp``NF N D��. DAPIA APPROVAL ZONE 3/EXPOSURE C': 8' MAXIMUM HEIGHT ZONE 3�DSURE 'D': 28' MAIOMUM HEIGHT fq • �F -.,, APPROVED BY '�•� �O?�G1ST o• F� �• ' 5 10 5. SEE AD-TD-OD35 FOR ADDITIONAL NOTES •' riEa IN:.c;,=iE INC �.'• STA9�9�QpF 100*11111 HOMES NOMCE-JACOESEN THESE sP munm w mu,,`;m" "' �� C.L.Y. °A� 5-30-95 MY. LETTER: P.O. BOX 368 OppMATERINS M MAC PFOKI aY, AM CCNFLOIM OF JAC11851Ti MAMIFAeuM W_ M MAIERWS ARE q,� To THE /-'1 DRAWING RTIE: FIG. 7.O SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 ISlpw fat 91= AffiP s No Mw K OUT CWWTK AID mmT Taal omm DRAWING NUMBER AD-TD-0041 47 ADDENDUM MISC. TIE -DOWN PROTECTION OF STRAP IS PROVIDED AT UPPER CORNERS BY FIRST WRAP OF STRAP. SEE DETAIL 'B' SEE DETAIL DETAIL 'A' IUCKLE WITH 31501 Y MINIMUM (DESIGN LOAD) DETAIL `B' NOTES: 1. SHOWN ABOVE IS ONLY ONE METHOD OF STRAP ATTACHMENT AT BEAM -OTHER METHODS THAT ARE CERTIFIED TO MEET THE REQUIRED DESIGN LOAD OF 3150# MAY BE USED. 2. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). L -BEAM I DOWN TIGHT TO DUND ANCHOR INSTALL RADIUS CUP (SEE AD-TD-0200) OR SIMILAR DEVICE TO PROTECT STRAP AT ALL SHARP CORNERS. DETAIL `C' THIS TYPE OF PROTECTION MAY BE USED FOR PROT;gl3pN,,AT LONGITUDINAL TIE CONNECTIONS ALSO. �- sT11 .'qF' I DANA APPROVAL: • Q 910334 0 APPROVED EY STATE OF :'ccIN I FfDERAI kMUFACTURED HDh1E ' s/pN •`` Z frD�IAISAF i>A IE D AND AT FIED OTHERS NOV 2 4 INN JACOBSEN HOMES NOTICE; THESE sPEancATas AND ORAWNCS ARE DRAYM BY: M.T. DATE: 11-18-98 REV. LETTER: ORONAL. PROMTARY. AND COWDfNTU1 UATM"LS OrJACOBSEN 4ANUFACTURNG DRAMNG TITLE: B ,�� P.O. BOX 368 MISC. TIE -DOWN SAFETY HARBOR, FLORIDA 34695 INC. SUDi UATERIAIS ARE PROWED 70 THE RECFIHT FOR SPECFIC PURPOSES MD MUST BE DRAHING NUMBER: PHONE (813) 726-1138 KEPT COiMnk AND SECRET TRW OTHERS AD—TD-OOSO 48 ADDENDUM Res NORMAL TIE—D ZONE II &III/EXP. C & D TABLES LONGITUDINAL TIE —DOWN SPACING TABLE l�yo MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III InN. OTT. EA. END OF u sEcnoN ANa+Da ANGLE MN. D Np1 On EA. END OF E.A. SECTION ANDIOR ANGLE Iml. e 364 3 40 3 25 VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX WIND ZONE 11 WIND ZONE III FLOOR WIDTH EAVE OVERHANG sPAaNG DBL HAD Ava�R ANCLE SPACING LOAD ANLHM ANGLE 30'-8' 6' 6'-9' 31501 41-46 5-5- 31501 1 44-49 LONGITUDINAL TIE —DOWN SPACING TABLE \0 O MIN. FLOOR WIDTH VIIND ZONE d WIND ZONE 01 MIN. T. EA. END OF u sEcnDN ANLE ANGLE Of. e EA. DO EK10F O u SECTM AN LE ANGLE NDL e 364 4 42 4 25 VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX WIND ZONE II WIND ZONE III FLOOR WIDTH EAVE OVERHANG SI'AONG D LOAD AN01Qt ANGLE SPAONG LAD AN010Ei ANQE 30'-8' 6' 4'-6' 31501 46-50 4'-0" 31501 49-52 VANOZONE III (110 MPH) 20 PSF ROOF 10 PSF D.4 REF. CADS G w,c� _ 14. GI — ,,,1TtIlIILLITT,�, NOTES: I. SEE FULL ADDENDUM FOR ADOI710NAL REQUIREMENTS. 2. SEE AD-7D-0071 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE �0. �. .. '' G ST R • \No. Fo'-: 910334 - z {r eeo * = OW APPROVAW 0 S M/iK APPROVED BY INF14INC. STATE OF' '�:, 0 '��`/ `N o�an�aauuowa:trswa�oc JACOBSEN HOMES ■ P.O. BOX FLORIDA;; SAFETY HARBOR, ORI34695 PHONE (727) 726-1138 N TNE9: �Et7i1GTICHS0NS AND ND oRArrNCs ARE ORICINAL• PKIWTART, AND LXfMNTIAL 9H W � � D T1in FUAENT FOR SPCOLIC S OM IE MIDI cautoatut MD gmo mom Dnats AWN BY. M.T. DATL 2-8-99 REV. LETTER DRAWING TITLE: NORM. SPACING TABLES DRAfl1NG NUMBER AD-TO-0070 49 ADDENDUM[ TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS SET mom HEAD TIE -DOWN SYSTEM FIGURE 10.0 SEE FIGURE 20 FOR ALTERNATE IE-DOWN WHOD FIGURE 10.1 SEE FIGURE 50 FOR AL'IMAlE 'DE -DOWN MMD % 1. SEE AD-TD-0070 FOR SPACING TABLES :.; NO. 2. SEE AD-TD-0070 FOR WANITY OF LONGITUDIAL TIE -DOWN STRAPS REQUIRED. z 910334 3. SEE OTHER DETAILS FOR BLOCKING (PEER) QUANTITY AND OTHER REOUREMENTS. SEE OF �ac 4. FILL ADDENDUM FOR ADDITIONAL REOUREMENTS. s. ZONE 2/EIPOSURE V. ss' MAXIMUM ,.-0 : STATE ; t 'p HEIGHT �',���: ' 1 A� •'`GNP c ZONE 2/EXI'MK V- 40' MAXIMUM HEIGHT ZONE 3AX POSURE V: 56' MAXIMUM HEIGHT ZONE 3/EXPOSURE V: 40' MAXIMUM HEIGHT .. '�i� s',� ✓�' \�' �i�,, �• ���� JACOBSEN HOMES ffM SPELTF1CArvTIONs NO ORAANCS ARE ONWAL, PRO14OUARY. AND COXFOEMTIAL P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING „ THE SAFETY HARBOR. FLORIDA 34695 M SUCH MATERALS ARE PROVIO D TO NEOPDIT FOR SPE= PURPOtTES AND MW BE PHONE (727) 726-1138 ID'T COMFIDENIAL AND SECRET FROM OTHERS Iz SE NOTE 5 FOR Mn" NOW IAQNDZONE III (110 MPH) 20 PSF RO 10 PSF D.LOF APPROVED BY i ON 14 INC. FEDENL MNAHF,CIUIiDM01E I C0j511ULDDM``M�gO1�Ss"ff Svm m6 e�li'ri� 1: it -04 M.T. 1 3-1-99 TITLE_' FIGURES 10.0 AND 10.1 NUMBER: AD— TD-0071 REV. LETTER:II 50 ADDENDUM. NORMAL TIE -DOWN SPACING TABLES ZONE lI & III/EXP. C & D IVQM%'5 S%t 1p 3 1p j LONGITUDINAL TIE -DOWN SPACING TABLE (1� MIN. WIND ZONE n WND ZONE QI BOOR A. CITY. ANGLER OTY AN ANGLE v WIDTH EA. DID OF ANGLE EAA.. DO OF �0 Lax. UK EA. SECTION e 154 . 3 45 3 35 VERTICAL TIE-DOlYN / FRAME TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH MAX EAVE OVERHANG WIND ZONE II WIND ZONE III SPACINGLOR9 D9L HEA9 ANGLER ANGE SPACING O L KA LOAB AxaIER ANGLE 154 6' EACH SIDE 6,-10' 3150i 40-46 5'-6' 31501 42-47 j� O VV �U LONGITUDINAL TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH VAND ZONE II WIND ZONE III Ma• T. EA ENDD OF EA. SECTION ANCHOR AN MIN. 6 A. OY. EA. Da OF EA. SECTION ANCHOR N1ClE YIH. B 15'-4' 3 30 - 4 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE 0 WIND ZONE lu FLOOR EAVE DBL trap DBL HEADWIDTH OVERHANG SPACINGDBL LOAD MOM ANGLE SPACING ANCHOR ANGLE 15-4' 6' EACH SIDE 4'-6- 31501 42-50 4'-0- 31501 44-50 NANDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALCS. �, rl; -�2, (/I - 12 , 1G NOTES: ENQ`I �Pf'�OV r�� lam, �i.,�DAM APMVAI. 1. SEE FULL ADDENDUM FOR ADDITIONAL REQUIREMENTS. ���Q',STEgf•YF`l 2. SEE AD-TD-0073 FOR MAMMILIM PIER HDGHTS REWIRED FOR THE LOADS Q No. Fo '•. APPROVED BY TABULATED ABOVE 910334 3., MAX EAVE OVERHAND REFERS TO OVERHANG AT SDEWALL NOT FRONT OR REAR. -a •. STATE INC. 4. ABOVE TABLES APPLY TO 184' FLOOR WIDTHS WITH 95 1 /2• I -BEAM SPACING, 96• MAXIMUM SDEWALL HEIGHT AND 6r MAXIMUM SIDE �� ••• D P • �` FMPA � OVERHANG (6. OVERHANG MAX EACH SIDE OF UNIT). ',� �`s ' \ �` oolat�v�AloiwRlRtwcwta , f� JACOBSEN HOMES NOTE ��LI I� BY: DAIS REV. LETTEtt n�Es< sPEoncATroNs An oRAw,a ARE M.T. 2-8-99 OR)MAL PROMETARY, AND CNIDENTIAL DRAWING TITLE - P.O. OF AACOBSEN UMWAMRMG „ P.O. BOX 368 we soa UATOULS ARE PROVOCO TO THE NORM. SPACING TABLES SAFETY HARBOR, 1395 Pio wsDRAWING NUMBER:PHONE 726-18 Kcar+nKNTK ANDMIWoHM AD-TD-0072 51 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS MAX PER AD-TD-0012 TABLE PER AD-TD- MI2 TABLE PER AD-TD-0012 TABLE PER AD-M-OX2 TABLE PER AD-ID-0012 TABLE MAIL FIGURE 10.2 SEE FIGURE 2.0 FOR ALTERNATE TEE--DO►N XMI) TYPICAL CROSS SECTION SHOWING -TIEDOWNS s SEE NOTE 5 FOR MAXIUM HEIGHT N ANGLE OF ,,� FIGURE 10.3 ( ) SEE FIGURE 7.0 FOR ALTERNATE M-D011N IiEt'fIOD NOTES: 1. SEE AD-M-0072 FOR SPAM TABLES AND NOTES. Z SEE AD-M-0072 FOR WANITY OF LONGITUDINAL IE-DOW STRAPS REOURED. 3. SEE OTHER DBMS FOR BLOCKM (PER) QUANTITY AND OTHER REQUIREMENTS. 4. SEE ROLL ADDENDUM FOR ADDITIONAL REQUREMENTS. 5. ZONE 2/bIPOSIX V: 56' MAMMUM HEIGHT ZONE 2/0FOSLIRE 'D': 56' MAMMUM HEIGHT ZONE 3/0PO9IRE V. 56' MAAMUM HEIGHT ZONE 3/0P0SLlRE V.- 56' MAIOMUM HEIGHT JACOBSEN HOMES „ P.O. BOX 366 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 REF CALLS. C u� - 9 z ENq - 'w, DAPIA APPROVK v • e. �i No. 910334 -q. STATE CF THESE SPECIFICATIONS AND DRAIMGS ARE ORIMIAI. PRMUETARY. AND OOF MIAL MATERIALS OF J C08SER MANUFACTURING FNC SUCH MATE36ALS ARE PRONGED TO THE F OMY FOR SIWX KIWMES AND MST BE PUT CONFNDIGAL AND SEDTEI FROM ODDS NANDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L Jrw APPROVED BY 000rA I 'N FID)EIYIMNQAf:IY®IOE INC. (OiAICR111AlORM��OTIq x004 M.T. DATE 3-1-99 REV. LETTER: FIGURES 10.2 AND .10.3 L AD-TD-0073 52 ADDENDUM �g�5 OFFSET UNIT TIE -DOWN SPACING TABLES N 1 11• ZONE II & III/EXP. C & D 11 �, LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE A WIND ZONE W FLOOR NIK CITY. ANCIICR WL CITY. ANCHOR EA. A END OF ANGLE EA. OFE RIM .�O v ESL sEcnoN uK a EA SM sEcU wt s 12W 3 47' 3 61' 13'-4' 2 54' 3 41' 15'-4' 2 54' 3 41' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WEND ZONE I IWND ZONE W W� OVERHANG EAVE �' �LOAD� ION An ANCIaF SPACING LLOADD 08L HEAD ANOHOR ANGLE 12'-0' 12' 5-0' 31501 40' 4'_0' 31501 39' IS-4' 12' 5'-0' 31501 41' 4'-01 30001 40' 15-4' 12' 5-0' 31501 43' 4'-O' 3=1 4T LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE I IM ZONE NI FLOOR HL CITY. ANCIN MN. CITY ANCNOt WIDTH EA. EOF ANGLE EA END OF O EA.SEC tlaN MIN.. a EA SECI� IN MIN. e 12'-0' 4 45' 4 60' 13'-4' 3 45' 3 60' 154 3 r 45' 3 60' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. NO ZONE I WIND ZONE M FLOOR WTH EAVE OVERHANG SPACIIG In ANCHOR ANKLE SPACING WIL HEAD I= ANm ANGTE 12'-0' 12' 4'-0' 31501 40' S4 30001 3r 13'-4' 12' 4'-0' 30651 41' S-0' 30001 39' 15-4' 12' 4'-0' 30651 43' 3'-0' �1 41' NOTES: it6f - C4Lz5, c- sL - 1.6 O1- 16 , lL ENGIm API'jIQY11L�N iff.., REF. ULCS.(C— 0- 17,01 - ••• 1. OFSECTION WITH THE MARRIAGE LINE EXTDM BEYOND THE ENDWALL OF #'. •. G. D . • •• • •.O�Q •ems l %� &*FSET '•� THE AOJAM SECTION MUST BE TED DOYIN AT THE MARRIAGE LK IN ACCORDANCE �• �..rY�'TfIF�Cq� M&D BY WITH THE TABLES ABOVE THE SDEWAIL SIDE AND THE ADJACENT SEC110N(S) ARE 1T) BE TED DOWN IN ACCORDANCE WITH THE NORMAL SPACING TABLES (SEE AD-ID-0010 'AND • • � X FOR 12W ! 13'-4' WADES.AD-1D-0070 FOR IS'-4' WDES� �JUN 2 SEE AD-TD-0001 FOR ADDITIONAL REWREMENTS. S # STA C I SEE AD-TD-0081 FOR MAXDAI I PER HEIGHT REQUIRED FOR THE LOADS TABULATED s ••.� P .••• Q+�, I N ` • OR ABOVE .• �44'� lmANURUND HOME QAffr JACOBSEN HOMES mm s > Am m : r .s��°`•T• 6-8-04 MY. `� ,. P,o. Box 368 . �K• WMARY, K AM W DRAWNG TIDE: OFFSET SPAaNG TABLES DRAWING N� AU—TT)-0080 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 ffi7w FOR SFM PIAIPM XIFT OoIIIIOE mx AND swmv e� ,63 ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOVING DE -DOWN SPACINGS FIGURE 11.0 SN MIN 4.0 MR ALi®N E 711-DOIN TD?TBOD TYP. CROSS SECTIONS) SHOWING MOONS SEE NOTE 5 RR YAwm IBQR (TNILES ON AD-m-OHO Dam APPLY M HE SHAIDAD 140-M sEleaollS OF NE MIT -SEE NX % AD-16-M] TIP. FLOOR SVM--7 >• i AIKIR AIM —N It f I— mmm AMQE ME c���G• FIGURE 11.1 C ) sv- lz,°(- l6� l2 so mm a >amt AEtIiATB tDI-ma s® Tr. ANM AIIQE—N R (FF c'4lc' FIGURE 11. Qc'g° pi Boa ATa>mruts �notm �oD NOTES. O"wv_ 008% ^ ��?� DAPIA Armuvm: 1. SEE AD-ID-0 FOR SPACING TABLES (OFFSET SECTION ONLY ~*'•�'�ftFl {t`'s APPROVED BY 2 SEE AD-TD-OODO FOR OUANITY OF IONQTUOIAL TE M -W SWAPS REMI ED. �� 'C,i� 9�•. �/ (OFFSET SECTION ONLY) o.00454 �'- 'I SEE OTHER DETAILS FOR BLOCIQNG (PER) GUANTITY AND OTHER REQUNNEINEHTS. 4. SEE AD-TD-0001 FOR ADDr110NAL RENREMDNTS.56 pL 0 E i/El b'r u L -3s• FOR 12'-0. WIDE UNIrS �, 9� A, „ QP ZONE 3/E)a'OStIiE 'C: 48' MAXNYIIM HEIGHT l31� • , ZONE 3/EXPOSLK V: 40' MAXIMUM HEIGHT s si' •-•...•••r D TzoTT JACOBSEN HOMES T, etirr" THESE sPEa1cA11ons CIRD DRnwlrGs AARERE ORMUL. PROIVETARY. AND COIiDE M DRANING P.O. BOX 368 MAIQIALS OF JACOBSEN YANWAC111 M INC. SUCK UA1i MS ARE PROUDER 10 11E SAFETY HARBOR, FLORIDA 34695 ROIPEAT FER 901C RWOM AM MAT BE PHONE (727) 726-1138 IIPT WfE VIAL AND SUM FrA GUM JUN 11 20 INC. UREO HOME SAFETY STANDARDS DATE: M.T. A6-8-04 FIG. 11.0, 11.1 & 11.2 It: AD-TD-0081 w 54 ADDENDUM ALTERNATE OFFSET UNIT TIE- DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN SPACINGS FIGURE 12.0 SEE FIGURES 11.1 AND 11.2 FOR TYP%,,S- #,•% %_ Sill NOTES: ..��STEgFO I. SEE AD-TD-0080 FOR SPACING TABLES (OFFSET SECTION ONLY). N0. •. L SEE AD-TD-ODSD FOR OUANITY OF LON(iIUDIAL TIE-DDVN PUPS REOUIREO. � 910334 (OFFSET SECTION ONLY) I SEE OTHER DETAILS FOR BLOCKING (PIER) Dummy AND OTHER REOUIRENENTS. .0 STATE Of ,• .� 4. SEE AD-70-0001 FOR ADDITIONAL REOUIRENENTS �9��• •,Np(a��p ` SEE ClfG:S, PG, G- sd- 16 .Gi SECTION y i� Lei � I I \'•� �,.�. :P.A. IOANJUFAMIAM li' A. - STRLIG110N file•[) SAFE Y STA :u;i;_•S JACOBSEN HOMES NOTICE: DRAWN BY: DATE REY. UTTER: TwESE �ER7I1R:AnoNs AND DIIAIMNGS ARE R.R. 5-9-01 ORIGNIAL PWRRIIARY. AM CONFIDENAAI DRAWING Ti1i.E: P.O. BO% 368 UVERRuks of JACOBSOi MOWACTINIM FIG. 12.0 — SAFE7Y HARBOR. FLORIDA 34695 M4. 9KH MAVF S ARE PROMDED TO THE PHONE (727) 726-1138 R�rr°iiI VALrOlt LANOXCREisAND FI o�ilclK�s DRAWING NUMBER AD—TD-0082 56 ADDENDUM����S 'u101 108" HIGH SIDEWALL TIE —DOWN SPA ING TABLES 1 ZONE II & HI/EXP. C & LONGIT INAL TIE —DOWN SPACING TABLE ,�1 NK WIND ZONE N WIND ZONE N an ff mom IWGLE uK on EA. Q mc"m ANGLE Q FLOOR WIDTH SfCA0I1 XC Ytl A EA. SEC110N S 1®L A O� w� Y6'-g' 3 42' 3 53' 3 57 4 45' VERTICAL TIE —DOWN / FRAME TIE —DOWN i SPACING TABLE MIN. MAX. WIND ZONE I WIND ZONE 0 SPACNC L WA AN01M ANGLE SPAM 08L WAmm LOW ma EAW WIOO OVERHANG 26'-8' r 6'-8' 31501 40'--50' 6-4' 31501. 4O' 50' 30'-8' 6' 6'-8' 31501 40 -50' 5'-4' 31501 47--50' LONGITUbINAL TIE -DOWN SPACING TABLE MIN. WIND E Y WIND ZONE M of END OF AN01E ANGLE IL on EA. OF mim ANGLE w� FLOOR WIDTH secnoy MIL EA. stc= nGLl 1alL A O� 26'-Ir 4 41' 4 57 30'-8' 4 51 4 70' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE A WIND ZONE 0 �' CK m WAD man ANGLE SPACK ML HEW LOW ANM ANGLE FLOOR EAW WIDTH OVERHANG LOAo 26'-8- 6' 5'-4' 31501 40'-5(r 31501 40' 45' 6' S-4' 31501 40'-50' 4'-0' 31501 40 -45' 1NNDZON: M (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALM ++,,��illflfflj. • i OW APPROVAL GtiwtIcq :'+' APPROVED BY 1. SEE R AL ADDW= FOR ADO IMAL REMAlUENTT Na 0045484 •y Oro 2 SEE AD-1D-M FOR W>QNIIY POt F EIM REQUIRED RR THE LOADS rN .t TAB"18 ABOVE INC. �++r��/'•., �OR1� .� �. FEDERAL MANUFACTURED HOME `;�• 'i+JSTE•a p ECjG'� CONSTRUC110NANDSAFEr(STANDARD� � '•/, 1it" JUL JACOBSEN HOMES NOnC& rAme em� 1m �1m MANI BT: M.T. DATE o�-2a—o4 REV. LETIM DRANNG TIRE- 108' HO 9DEWALL SPACING TABLES ILA MmAL pROPi UMX AM ao�u� MA,� OF � WWA P.O. BOX 368 SAFETY HARBOR, FLOROA W95 PHONE (727) 726-1138 W_ 20 YAiAUJ AM FFAN D 10 1E RgpW P01 SM P0i'W NO W9 E WT cos>oamm MO smW FFM OXW I DRAMNG NIMIBEit AD—TD-W83. 56 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING IE—DOWN SPACINGS . TYPICAL CROSS SECTION I I SHOWPIG TIEDOWNs Tr. Rm AHHOHOR MGLE AM M HEM FIGURE 10.0 FIGURE 10.1 TV. Si NOT S HTIR Illm 111 HEIGHT ANm X E v_- Ig•01— (0..z VANNONE 0 (110 MPH) 20 PSF ROOF 10 PSF D.L NOTES: 1. SET: Ao-To-6oaT FOR SPACNC rA� ao Cif` •'�F �A ' ��� '�. D PIA APIWIVA : ? APPROVED BY 2. SEE AD-M-M FM aAMTr OF UNGMIDIAL TE-000 STRAPS KQA M a � 1 SEE OTHER DETAILS FOR 111.00M (PER) OUAMI1Y AND OTHER MCILI F OM C i 4. SEE PULL AMEHDLIM FOR AMMON& REMM311ENTS, T¢ • % S ZONE 2/01POS K W: 36• MAIDMM HEIGHT ZONE 2)UPOSLK V: 23r MAXMN HEIGHT •• % ~" 'y S ,�t�, r• ��, '••. Q ,�� � I v 1 C. ZONE 3/E1�AE V. 36• HA)61M1 HEIGHT ZONE 3/EXPOSLRE V. 3Y MAIM HEIGHT `OR� &If* �il��.,r �•'!. ' ' • �� ,� FEDERAL MANUFACTIKO HOME RLIS CONSTRIICTICTNA1T1181AtFEHY;f 6. ALL SPECWATIM ARE BASED ON 21r ROOF ANGLE MAX- �Iof ED �N"ibl.. � '%(iC11 JACOBSEN HOMES xo1>�:-� of :. �� �. ��o „� �,,,,,s NO oRA+�s ME , � : M.T. 07-20-04 rT a1eaMK. Twxr N+o Oois�tx�ul DRAgMC 1T1Es P.o. sox 36B �; " nGl1RES 10.0 AND 10.1 SAFETY HAREN K FLORIDA 34693 �R � E pp KW K DyI PHONE (727) 726-1135 WT ONEM = Sr Rm obey AD—TD—OM 57 ADDENDUM 108" HIGH SIDEAd[b TIE -DOWN SPACING TABLES ZONE A & III/EXP.. C k D ti0. LONGITUDINAL TIE -DOWN. SPACING TABLE mH. in ZONE I WE ZONE II FLOOR - w an ARXn ux OR AHORO WIDTH Ell W OF ANQE 6L FAD EF MCLE Eel SEC°OI lox 1 EL SECIV MIL I 214 2 58' 3 43' 3 45' _ VERTICAL' TIE -DOWN FRAME TIE -DOWN SPACING TABLE ACN UAL - WND ZONE I WIND ZONE 19 7ADTHH OVQt G OR EAVE �AONC LOA MNW AHORaa ANTE SPACiIC u AN0lgR AMQE 6'. 6'-8- 31501 49' S'-4' 3150 45' 24'-O' 6' 6'=8' . 3150 49' Y- 4- 3150 45' LONGITUDINAL TIE -DOWN SPACING TABLE WN. W01D ZONE I U ZONE III FLOOR Ot QTY. ARO1lTR lox Olt moo WITH EA Do Ot AMC1E EIL DO OF ME O r� EA. SECM NN. 0 EA SEC110 H L 0 13'-4' 3 48' 4 43' 14'-0' 3 5T 4 •45' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE WIL VAX WIND ZONE I WIND ZONE 19 VAOTHH OVERHANG SPAM LUD AHGRDR ANQf PAM; MaE LOADANWI 214" 6' 5'-44 31 47' 4'-0' 3IR 43' 24'-0* 6'1 6-4' 31501 47' 4'-0* 3150 4Y 108' MAX SIDE:WALL HEIGHT wwDZONE 11/10 (110 MPH) 20 PSF ROOF 10 PSF D.L. Rff. CJ1= NOTES: •`;•(1F'c. oAPu► A�aovAl: • RE A FU 1. S FE LL DDE7ROUY FOR ADDIAONAI. OUFtEl1DRTi a �� • • �`+ s : G$ h� + APPROVED BY . ON 2. SEE AD-M-M FOR MA10 N PIER HE1f O REOUW FCR THE LO YAOLLATEO AWVL s Dec. 13,2006 r o -� ING. ATE KVWACnM W W connrtucnW Amp SAFETY STAilDMOS JACOBSEN HOMES AiS85PE0nCANmaA�DRAM=w ew R.R. 11-28-06 �t RETTER P.m Box Jma ORM7MAL M AM CUNFMVL YAIMMS CF MCOM nAMWAMOMQ IC SM VAUXXS AM PPMU to lK DRAMN6 A1LE 108' HIGH SIDEWALL SPACING TABLES SAFETY HARBOR,) FL0Rl0A 34695 PHONE (t27726-113a - A� IQ SM Rw= AND = K 1si CDOMPAL M SWI[1 FY= 4*= DRAW NIAIBEfR: A�_�--0085 58 ADDENDUM TIE= D4 WN SYSTEM MCAL SIDE 01VAIM SHOWING 1[-" SPA00. TYPICAL CROSS SECTION SriOWu(G TIEDOMS TV. ROOT •FIGURE 10.0­ - TIP. @0*tD6LR —� / WU AAi Inver r ANm mu CR A1FRo1ED SIABIL1Ql SETA00 16TALED Tt1N wo WR M33A 9]E M X� FIGURE 10.1 `110 MPH) or I,.) 20 PSF WOF 10 PSF D.L REF. CALLS ,tstN:!lttl�� N0� 10-Does FoR SPAONO U Es `•. •... +' DMA R RMAL• APPROVED BY �O. `�'�;.�i1� L SEE AD-10-M FOR OUANITT OF LOWILIDIAL K-DOW STRAPS REQIt1ED. 1SEE o>tIL1I DETAILS FOR eloaa4c (PER) OUANnTT AND onTERR REDUTAEYENTS !v?. C+3 ` 4. SEE 4U.L AOMMim FOR ADOITPIAL REOIME11EK1s :ON Deo 13,2006 PINC S ZOKE 2/DPDM Y 4C UMN KE W ZDW z/W0� �: 21r YAWN NW(T « � i �.�: ZONE 3"09RIE -V- 44. 41A101RAI KE16KT ZONE 31UPO K b: W YAM W HEW : +n .- 'p '. ps . � � ; •��+• � rMRa uuNAcAe�uNeo NorE C0167RNLTIDN AM WEW tTANDNnS 6. ALL spancovis AK BASED ON 20' ROOF ANQE YAX AND Ioe MAX 90E11ALL NEn11 • L�17��±Y.• C% C "••..• � ,,y1 JACOBSEN HOMES Alit%�Vx WX� =e AAA R.R. DATE: 11-28-06 I LL IEi1Htk DRAVIC 1TILL FIGURES 10.0 AND 10.1 WOOL M OUML AD 0"COHM "AWRU °i AWOM 1OIAIfK7AW \� P.D. BOX she W- 2101 UA1Du13 Alt FttM TO IK DRAWN MINER: Ali—M-0086 SAFETY HARBOR, FLORIOA 34693 PHONE (727) 726-1135 Im w RX vwrc pj r AND n K err CWMIAL wo RM nor CUM - ADDENDUM 1c�R�s (108 PIDEWALLP) � �, NORMAL TIE -DOWN SPMdINC TABLES ' ZONE II & III/EXP. d & D ��- LONGITUDINAL TIE -DOWN SPACING TABLE {1 �lir 0h Z I Z04E 1 OT14 t o O • t�r FLOOR 00 Lk%M* �Il 6 FA SECXh `IMi 0 121-0` 2 53' 3 40' 1 13 -4` 3 3T 3 1 46' 3 46 4 40' VERTICAL TIE —DOWN / FRAME TIE —DOWN PPAOIN0 TABLE VN. VAK D ZONE H ZONE HI VAX am ,�. SPA* VAX m Ahow At , FLOOR *DTH EAVE OVERHANG 12'-0' 6' EACH SIDE 5'-4' 72` 35' TO 4a T-4' x 45' 13'-4' a EACH SUE 1 5'-4' 80` 35' TO 40, 5-4' 42' 4S 15-4' 6` EACH SUE I 5'-4' 80` 40' S-4' 46' 4T LONdITUD1NAL TIE- DOWN JPACING TABLE NOw ZONE li LONE III FLOOR OTT; s OTT: Or, 40� EA C110N �1. 99 EL SECTION�l e 12'-O' 3 . 44 4 40' 13'-4` 3 52 4 45' 15�-4` 4 44' 4 56' VERTICAL TIE -DOWN / FRAME TIE -DOWN OPACINO TABLE VAX OD ZONE I zoNE 8l SPA* V��R AhM kW' SPA* YAX m Allo0 All * FLOOR 1MDTH EAVE OVERHANG 12.-0 6 EACH SCE 4'-0• 72` 37' 4E-0' 34' 40' TO 45' 13'-4' 6 EACH SIDE 4'-0• V 40' 4'-O' W 4O' TO 45' 15-4' r EACH SK 4'-0' ff 40' 4'-0' 42' 40' TO 45' • NOTE: WHEN ANCHOR ANGLE FROIrt VERTICAL CANNOT BE REF. CALM ACHIEVED. ADD APPROVED STABILIZER PLATE. (SEE NOTE 15 FOR HOLIES SET IN FLORIDA) Np d: EN ....... �` ^ rr DAP9A APPROVAL: s,�� �, ;� ;... -, :f P APPROVED BY • '✓ 1. SEE FM FOR AWRONAL REOURtEIIENM ;+ •- ��,: '� Z TAB1E BASED ON AitCF10R DRIaNc LOAD OF 11501 AND D"*k TIE TO O�� � o is.. `r� -: �.� Mar 25,2008 .NC. �7R...rlll.RED I VAX EAVE OVERHANG REFERS TO OVERHANG AT SDEWALL NOT FROIIT OR REAR .. NWE � f7/ �.��]F. •: .. CON9MCNON AND SAFETY STANDARDS " 4. TA$FS APPLY TO 1�4' 160' AND 184' FLOOR �TH � 95 1/i SPAW, for SOEWALL HFJP/1T AND 6� WE y'�;ii : ; •- -' ` OyfRHANC (6' C EAOL SIDE OF 00111�'•;�1L/:�iv'�:• � t ,If u" 't'�••• • . `'�� i STAmm PLATES ARE REOtA O ON SDE1kALL A1t010RS AND LOWTUMAI. ANDm SET N FLORDA, SEE DIIV RULE jr- uncnx WOO 29. t999 � 4` t�j r7 p �t3 .fit J ACOWEN HOMED NOROd� � ��fA� MID�A ARL OA : D.V.T. DATE: 1z-11--07 REV. LETTER oRA �Tc TITLE- MomNORM P,o. 80x 3Ti8 + L AWA�w eSsuhDNIAaWd bi PNOY�OYFpD� W1 iHF SPACING TABLES DR G pp_ Tp-0087 nwn SAFETy PHO MDR. FLORIDA 138 95 +��TOdF1pE1 Alp Y :Rall oio�s� vv ADDENDUM SHEARWALL TIE-DAWN/PIER REQUIREMENTS at: slur umm , DPf. " LJ;t m Cc" X.t.t "a *am 011110101mimlolmloll Trio FU SHMAW (ALL sTwTi ) OE-o"m Nxim ar. sm uum tn. $/V uwGrH t tv� R mat w moo 114q ps g"Was 4(ILL iINA1oR) 10,ml v mm I %a Mir I v v� MOT( 1 SEE Now I� la Itons 2 No I Q Q MEE WM 2 AND 1 A ra jab 7W5 LOCATKW m FWD INN LDi'J►TIOH Ffil RWb IRS toGAy" Pmt mm'o THS LOCATION FIGURE 8, 0 FIGURE 8.1 THE DETAIL ADOW IS SHOWN WITH A TWO PIER SHEARWALL CONFIGURATION, HOWEVER, THIS DETAIL APPLIES TO All SHEARWALL CONFIGURATIONS, ALL ZONES, -AND ALL 14F VALUES. xorEs: YPfM RTTfw•I�. t. vi-amm waxi D if Wae MAX T[-ww mw XAT tt Loam 19 �� PPROVED BY UW Of lit A" DOM AM W RWM AT 10 , .;.;,r.. v� { ° o-A� im--arm+cRAL J rat m �101f aaso" M7XUMK) +� ._ �� � Fo'r I Eg 10 2000 i �Sm A m AT oaf Do iF flfE sa[m"L m" rOt T� Awx OQAIX� [vtor R AT clot 00 oe aysrs 2tcuauss -o� sTww hLaa�a� w, 910934 t NC. k >tflpi SF[AAIfFtI 6 LOCA107 Aft A 3Ul>O K iO01T QmaS-YO��Q no * ��� t * pAl MANUFACTURED HO%'JD ec-car sTws +aw AK RcaxtEo (ALL 9fEAROul1 aottilFtaltorQ ALL 7ITE3 : -o AADALL(iPaSK5 ?, ; STATe- .'4. NSTRW7loNANDSAFETYSS X. JACOBSEN HOMES v "WE0rK`"P`"°� •:.••''R.R. o2-01-00 KRU P.C. box 394 kfAWVLc CF 4k=30 Y� S/W TIE/PIER REO. B WET7 HARGM FLQRIOA 34805 era 9wc ffmm #A wave PNa F- (727) 724-1138 pwr WffWvt4 — Rd toeats • DRAM+�c tx:. AD-TO-100 61 , ADDENDUM DOUBLE SHEARWALL CONFIGURATION SINGLE -SECTION TIE -DOWNS / CEIM MAY BE FLAT OR SLOPED SIDE VIEW 1 1/4' X .035' TIE -DOWN STRAP CDNIINUOUS ARLXIND JOISTS. END VIEW 350 PLF MAXWIJ SHEARWALL DES.'GN VALUE (PER WALL) 1 1 /4' X .035' rF-^,CWN STRAP CONTINUMS, ARCJ\D MS7S. NOTES: Z 1% E)Q+J( : �VP�IROVAL: ' • ,? • •/y •� - ''� DAPIA APPROVAL: 1. 1ROM A.404MS TO BE RATED FOR AN ULTUATE LOAD OF 4725) (3150 DESIGN LOAOJ (SEE AD-m-Dao1 (m-GENERAL NOTES) FOR XoTES ON UtOUIp AW>IOR ASTuunDll.) _` •� - - 1 APPROVED 13Y 2. INSTALL A PER AT EACH END OF W SHEARWALL J01515 (PER THE ABOVE DETAILS). , ON 3. M$X 9,FARIJ1 IS LOCATED ABOVE A SCUD IWER GULL Koff c310S5-UEASFP.) No STRAPS. OR PERS ARE REOIIIRED (ALL SNEARWALL CONRCLOATICIRS, ALL ZONES -i � ` ArC-007JV AND ALL E7PO.�IRES). 4, TlE-DOIvv STRAP REOURIED i ✓.�'. ; ��` ' '' 1 I AT EACH END OF JOISTS, ALL DB: AM CONFIGURAT10H5. �i !. ' ., , ' ::': '�i,�; N 1 v V. S. CUM S OWN FLAT -OPT CATHEDRAL OR SLOPED CEILING MAY BE USED. 6. FULL ARE t)�^t • :"�����`` '''���i�r►+lilh�.++' *�`�'` rEocrAtwrlsEc:sE: !tiwxa�s cac:a:,arreu+.• VOTH SHEARWALIS SHOMI IN THE DOAL-ABOVL HOWEVER, ANY LENGTH OR COHTIGURAT04 SHEARWALL MAY BE USED. NOTICE CRAVIN BY: DATE: REV. LETTER: JACOBSEN HOMES .>� SPECIFICATIONS AND TNIAWNGS ARE R•R 2-6-96 OtM NAL, PROPRICTART, AID C( MENTIAL DRAWING TITLE: p P.O. BOX 368 UATER.ALS OF JACOBSEN ►IANUFACTUR:NC IVE DBL. S W CONFIG. TIE -DOWN i—„ SAFETY HARBOR, FLORIDA 34695 XOPEKI IOR ARE OS S Ago 'urs° T PHONE (813) 726-1138 KEPT ooNFmENfL4 AND S=.atT ntm oTITERRi DRAW:\,, HuueET:: AD—TO-0110 62 CEILING MAY BE FLAT OR DOUBLE SHEARWALL CONFIGURATION TRIPLE & MULTI SECTIONS SIDE VIEW SIDE VIEW (MARRIAGE WALL APPLICATION) �( (SIDEWALL APPLICATION) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) \� 1 1/4' X .035' TIE -DOWN STRAP ��- 1 1/4- X .035' TIE-DOMN STRAP MIN. CONTINUOUS AROUND JOISTS. CONTINUOUS AROUND JOISTS. TO 35' 1. GROUND ANDiORS TO BE RATED FER AN LLTMATE LOAD OF 47251 [3150 DESIGN LOAD] (SEE AD-TD-0OO1 [M-CENERAL NOTES] FOR NOTES ON GROUND ANCHOR NSTALLITION.) 2. INSTALL A PIER AT EA04 ETD OF THE SHEARWALL JOISTS (PEN THE ABOVE DETAILS). 3. NO SFEARWALL IS LOCATED ABOVE A SOLID HEADER (FULL HEIGHT CROSS -MEMBER) NO L TIE -DOWN STRAPS OR PIERS ARE REQUIRED (ALL SHEARWALL CONFTWRATIONS, ALL ZONES AND ALL E)POSURES1 4. TIE-001eN STRAP. REQUIRED AT EACH END OF JOISTS, ALL DBL S/W CONFIGURATIONS 5. CEILING SHO'AW CATHEDRAL OR SLOPED, FLAT CEILING MAY BE USED. 6. FULL WIDTH SHEARWALLS ARE SHOWN W THE DETAIL ABOVE, HOEVER, ANY LENGTH OR COMGLfRAT10N SHEARWALL MAY BE USED. 7. THIS DETAIL MAY APPLY TO TRIPLE AND/OR DOUBLE WIDE SECTIONS. John C. ElWeIi j.i 15133 C. R. 22 Goshen, IN 46526 N IS A TRIPLE WIDE RAFTER, ,APPLICABLE TO STANDARD ILE WIDE TRUSSES. JD VIEW X .035' ME -DOWN STRAP IIOUS AROUND JOISTS. DAPIA NOTE: ALSO APPLICABLE TO 'SUP SW MARRIAGE WADS 11144EN AT LEAST 2 STANDARD VERTICAL TIES ARE INSTALLED. (1 EACH SIDE ADJACENT TO SHEARWALL LOCATION) APPROVED BY lbI ON o� cnorosvcn�iurs�vx JACOBSEN HOMES P.O. BOX 368 NOTICE THESE SPELIEICATNINS AHD DRAwws ARE ORIONALOPENT, PROPRIETARY, AND CDI4IbENTLAI MATMALS OF JACOB'.,EN MAHUFACAANG��`S/W DRAWN BY: R.R. DATE 4-09-96 REV. LETTER: A DRAWING CONfIG. TIE—DONM „ INC. SUON MATERIALS ARE PRWmEO TO NNE - SAFEPHO R(813)FLORIDA 138 PVT AM DRAWING NUMBER: ETY 7261D MNIOR DWnAL Man rRu onNm AO—TD-0111 I.tm PORCH ANCHORING DOUBLE HEADED 3,1 OTES: 1. SEE SET-UP MANUAL AND ADDENDUM FOR APPLICABLE BLOCKING X .035" TIE -DOWN STRAP JOUS AROUND STRAP BLOCKS. t' •.: `: •' VIANDZONE III EXPOSURE C {11(l MPH) 20 PSF ROOF 10 PSF O.L REf.,cALcs .' c mi — I OR ,G I — ENaN)rRQHA�. ` DPPROVED BY 4.1 J AC O B S E N HOMES THESE SPECFICA77HOCH AND DiUwNLS ARE DRAW BY- OFAGNAL. PRORKTAAY. AND COKDF M DRAPING 11 m P.O. BOX 368 MAMMALS OF JAMSEN MANUFACTURING nc SUCH MANNA S ARE PRovm to IK RFA SAFETY HARBOR, FLORIDA 3*95 M FOR SPEDRC Pl MS AM MUST BE DRAVANG N�tl PHONE (727) 726-1138 K0n ooNHMUK AND SFIFT FROM MRS. 14INC. MANUFACTUREO HOME 0101N AND SAFETY STANDARDS I C li.4 mr- M.T. 1 - - 12-13-03 PORCH ANCHORING AD-TD-0112 f:7a'�iar:i 64 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION APPROVED VERTICAL TIE -DOWN ANCHOR BRACKET (FACTORY INSTALLED) FLOOR CRIMP SEAL (3150/ WORKING LOAD) s iC 3 10 �fp VERTICAL TIE -DOWN c TYPE 1, FINISH B, W d„4• GRADE 1 STEEL STRAPPING � `l A 1 1/4" WADE do 0.035" � %F IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS DIAGONAL FRAME TIE CONFORMING WITH ASTM STANDARD O SPECIFICATION D3953-91. 0 STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. RADIUS CLIP I I T RADIUS CUP MUST BE INSTALLED ON �— Ed I El I E ALL TIE —DOWN ANCHOR BRACKETS. (INSTALLER TO FABRICATE RADIUS CUP ANCHORING EOUIPMENT -III I 'I I -III -I I BY PLACING A STRAIGHT 3' LENGTH OF CAPABLE OF RESISTING -I I (-I I I —III— 1 1/4* X 0.035' TIE —DOWN STRAP THE WORKING LOAD MA7ET4AL IN ANCHOR SLOT AND BENDING REQUIRED ON THE TO FORM THE CONFIGURAMON SHOWN.) TIE —DOWN SPACING TABLES (SET_ OTHER III RADIUS CUP MUST BE INSTALLED TO PROTECT DETAILS FOR TABLES) I— III —III— THE TIE —DOWN STRAP FROM THE BRACKET EDGES. SEE OTHER DETAILS I I-III=III-I I INSTALL THE BRACKET *2 STRAP THE RADIUS CUP FOR ANCHOR ANGLE. ``\\\\\11111111111fAA/� \��X4 C. .` •57• (li OVA�O O'•. 'y DAPIA APPROVAL• NOTES: = :• ENE870357 � Y 1 TIE LDIAGONAL FRAME -DOWN STRAPS AND ANCHORING EQUPMENTSIJPPL _ Ov�D B BY AND INSTALLED BY OTHERS- ON SITE. T.^., Ey r :�� JUN 1 5 19 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING O'•. /v I •` (� SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— �'.,'��c' 'JlA • T ���� IN�..A. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS i��� iAL A�' Oti6iAtICIDSAIOiMO1Q110� i A A710N. r4 rl %% WHERE THE ANCHORING SYSTEM REQUIRES THE USE ANCHOR fBRAAAID TIE —DOWN OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). DEVICES ARE CERTIFIED BY OTHERS N079CR DRANII BY:' C.L.Y. DAIS: 5-31-95 REY UTTER JACOBSEN HOMES TKSE SKCMTM AO DABRE An PROPilCTANY AND CdU1oFN1U1L DUVOIG MU' P.O. BOX 368 W� DF �" " °A" X ALT. TIE-00M APPL. SAFETY HARBOR. FLORIDA 34695 oppon to sKem nIVOLS � AID um K DRAWING NUuBER PHONE (813) 726-1138 wl CDWWTAL MD sav 1110N o1HDIS AD-TD-0200 65 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION FLOOR IF FACTORY INSTALLED STRAP IS NOT LONG ENOUGH. — IT MAY BE LENGTHENED BY USING A CRIMP SEAL WITH A WORKING LOAD OF 3150 POUNDS to 0 t DIAGONAL FRAME TIE . I• ANCHORING EQUIPMENT CAPABLE OF RESISTING I I I• THE WORKING LOAD REOUIREO ON THE TIE -DOWN SPACING _ TABLES (SEE OTHER DETAILS FOR TABLES) I I SEE OTHER DETAILS FOR ANCHOR ANGLE. NOTES: 1. ANY ADDITIONAL VERTICAL TIE —DOWN STRAPS. DIAGONAL FRAME TIE —DOWN STRAPS AND ANCHORING EOUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). APPROVED VERTICAL TIE=DOWN ANCHOR STRAP (FACTORY INSTALLED) IF NEEDED, USE VERTICAL TIE —DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4" WIDE do 0.035" IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. r `\\\\\11111111fllllAl,� 910334 STATE le" = i? ® No CE JACOBSEN HOMES rib THESE SPEOr1CATIONsAANDRAMf'LT ARE ORONAL. PROPMETART, AND CONFIDENTUL P.O. BOX 368 MATERIALS OF JACOBSEN MNTUfACIMNG INC.. SAFETY HARBOR. FLORIDA 3<695 SLIO+ NATERN,S ARE PROND� TO THE REOPOR fOR SPECIFIC PO P= Apo WSl BE PHONE (813) 726-1138 XVT MWIDEN114 APO SEar rROu OTHM DAPIA APPROVED BY INPIREVISED 10I23% INC. Fm6R&MAKFACnffb%0W oofasTHuerr>w AND WEn NZANDOW DATE REV. LETTER: R.R. ]O-OS-96 ALT. TIE -DOWN APPL. AD-TD-0210 66 ADDENDUM COLUMN TIE -DOWN APPLICATION 1 COLUMN - - COLUuN l SEE TABLE FOR MAXILfl1Y SPAN FOR COLUMNS 'A' OR 'B' %COLUMN 'C' COLUMN ISEE TABLE FOR MAAMUM SPAN FOR COLUMNS 'C' OR T)' _ I SEE TABLE FOR SPAN COL i SEE TAKE FOR MAX SPAN FOR I�COLUMN'E' -jLUMCONfCQ1Lvr+'G' SEE TABLE FOR MAXIMUM SPAN•FOR COLUMN'F' MAXIMUM ALLOWABLE SPAN TYPE OF MOON REO D (SEE AD-7D-0251. COLUMNS W. 'C. V OR 'E' COLUMNS i3' OR '0' laU►N T+ AD-1D-0252 AND AD-TD-0253) ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 SEE HOLE 1 EXP. 'C' EXP. V E)P. 'C' EXP. '0' EXP. 'C' EXP. V EXP. 'C' E7�. V EXP. 'C' W. V EXP. 'C' E». 'D' 2 - 31501 ANCHORS 43'-0' 29'-6' 33'-9' 23'-7' 4S-0' 29'-6' 33'-9' 23'-7' 4S-O' 29'-6' 33'-9' 23'-7' 1 - 31501 ANCHOR 21'-6' 14'-9' 16'-10' 11'-10' 21'-6' 14'-9' 16'-10' II' -IT 21'-6' 14'-9' 16'-10' 11'-10' I - 40001 ANCHOR 27-3' W-9' 21'-5' 15'-0' 27-3' 18'-9' 21'-5: 15-0 27-3 18'-9'ENGINEER NOTES: APPROVAL' DAPIA APPROV APPROVED Bl(A,�r 1. SEE AD-M-0251. AD-TD-0252 AND AD-TD-0253 ON FOR SPECIFIC INFO. ON ANCHORS. -I 1 5 2. SEE AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR INSTALLATION. 14 INC John C. Doeden, P.Y 15133 C. R. 22 a„ Goshen, IN 46526 JACOBSEN HOMES N077C& THESE SPEonCATIMS AM DRAB AREC.L.Y. DRANK BY: DATE: 5-31-95 REv'LETTER: mmn MONAL. PRWWARY. AND COHIIOE m4L DRAT- 11TLE: COL TIE -DOWN APPL. „ P.O. BOX 368 MATBMAS OF A�eOM MANUFACTLA'W W_2 01 MATE W AK PWXM TO THE ORAMNG NUMBER AO-TD-0250 SAFETY HARBOR. FLORIDA 3095 REOAOR FOR VEOM PiRM NO "I K PHONE (013) 726-1138 PVT COW1101IAL NO IOU 110 01E11s 00 '67 ADDENDUM COLUMN TIE -DOWN APPLICATION ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. 0 ANGLE SHOWN. COLUMN STRAPS SEPERATE GROUND NOTES: 1. ALL ANCHORING EOUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. MARRIAGE LINE OF MULTI -WIDE ATTACHED ANCHORS .,Auullu,... VERTICAL TIE -DOWN TYPE 1. FINISH S. GRADE 1 STEEL STRAPPING 1 1/4' WIDE & 0.035' IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. TO TWO (3t5O# EA.) v'_l I APIA APPROVAL �X, �G� S T Eq �UF �'. Q No. s ENE8703571 % SE ^ 01A ,,Z/ONAL Ey AFF :,;C'v'ED BYA, Iil .ltRJ 1 5 IC Rm%v~Acfmm E I V JACOBSEN HOMES NOTICE ""' VRAWN BY. . C.L.Y. DATE 5-31-95 REV. LETTER THESE WEOFIGITIONS NO DRAMNIS ARE P.O. BOX CMAL PROPRaMY. AND cON1M71,4L YATUVa OF JACOMANUFACTURING DRAWING TITLE COL. TIE -DOWN APPL. /� \I SAFETY HARBOR, FLORIDAI 34695 W0I MATERIALS AREBSEN PRONGED TO THE We REOPO4 FOi SPF= FLON 3 MG WM EE /—` DRAWWG NUMBER PHONE (013) 726-1138 IOPT CWMTK NO SECRET 1ROM Orr AD-TO-0251 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF3150/WN. 101 MARRIAGE LINE OF AIUL71-wDE FLOOR VERTICAL TIE -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 IN WIDE & 0.035- IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. COLUMN STRAPS ATTACHED TO A SINGLE GROUND ANCHOR,,, (3150#) NOTES: I. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES. JACOBSEN HOMES 'I P.O. Box 368 SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 No.RFoF r..%a1�}4 y�r '%,s!aNAI Ey, N0710E TMM S'EMnrATI04 AND DRAMNCS ARE .0WAL, PROPRIETARY. AID CDIiDp1TW. MATETL W ucos9ll YANJFACTIIZ IC Si101 MATERIILS ARE PROMDED TO M RECRENT FKR VECM P JFM APO VM S Wl OOfTJE IK AND %(XI TR01 OTIERS BY. BY A, JM 1 5 W INC C.L.Y. I -'"_ 5-25-95 COL VE-DOWN APPL. It AD-7D-0252 ,, 69 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EOUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 4000 / MIN. R COLUMN STRAPS SINGLE GROUND NOTES: 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. MARRIAGE LINE OF MULTI —WIDE FLOOR VERTICAL TIE —DOWN TYPE 1, FINISH B, ,GRADE i STEEL STRAPPING 1 1/4' WADE do 0.035' IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. ATTACHED TO A ANCHOR (4000#) . _ .1111nuf,. ,��•G�STEk�VF No. FO'' • Fsn' o.. i. uliTAlA1• PPROVED BYE, 15VO Nil Op INC. "mftu "u.cnr®�oe c =MftcnAwsvmSLUM NOTICE: h, , WAWW sr C.L.Y. 5-25-95 JACOBSEN HOMES THM SK01"TIONS AID 0UUM AM CMMM. PRaP1O MY. AID aole>ol m DRAWING MILE m P.O. Box 36e sm TF TOIK COL. TIE —DOWN APPL. SAFETY PHONEE (813) 722661--1138 695 Im tafG0 ik No mm MO Onom DRAWING N1NBEl� AD—TD-0253 70 ADDENDUM TYPICAL SINGLE WIDE TIE -DOWN PLACEMENT SEE N01E 2 A B C 4 LARGE OPENING 24' SEE NOTE 1 BRACKETS (SEE ME -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXIMUM SPACING ALLOWED). ALSO SEE NOTE I STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A MAXIMUM OF 2'-0' (241 FROM EACH END OF THE UNIT. •O NOTES: PR y DARA APPROVAL: I. LARGE OPENING = ANY OPENING HIDER THAN MAX TIE -DOWN SPACING ALLOWED. :� ENE8703571 , - 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TIE -DOWN SPACI -•- - . ROVED BY SO LONG AS, THE AVERAGE SPACING ( (A+B+C) 13 ) DOES NOT EXCEED THE N MAXIMUM TIE -DOWN SPACING REQUON THE APPROPRIATE VERTICAL/FRAME IRED ,�'•. /� r' <c, �.� �'. .I W 1 5 IM TIE -DOWN SPACING TABLES (SEE 01HER DETALS). tc ' I .•\�� .�` I' C 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DOWN LOCATIONS. ��.,�sl�PlAL1YT��`v`�``� 4. SEE AD-TD-0001 FOR ADDITIONAL REOLIMMENTS .: =�: r .cSam n aiw ANCHOR BRACKET AND 71E-DOWN DEVICES ARE CERTFED BY OTHERS JACOBSEN HOMES r1oT1AM SPEN7FTG110N5 AND OKAYING$ ARE DRAWN BY: C.L.Y. DATE 5-31-95 REV UnaTHESE . P.O. BOX 368 ,I ORICINAL PROPRIETARY; AND COiDDITRAI UATERAIS OF utx� YANLWACI"C RNG 10 MATIMAIS ARE PRW= TO THE A DRAWWG nTli TIP. SINGLE WIDE T/D SAFETY HARBOR. FLORIDA34695 PHONE (813) 726-1126-1138 REmW i0R SIUM P1 VUB me MW K wy DRAWWG NUMBER CCNMTK me SIX T nm ormm AD—M-0300 72 ADDENDUM TYPICAL -MULTI-WIDE TIE -DOWN PLACEMENT SEE NOTE 2 A B C 24' LARGE OPENING 24' COLUMN SUPPORT TIE -DOWN STRAPS REQUIRED AT COLUMN LOCATIONS ON EACH SIDE OF CPENNGS GREATER THAN 49' N WIDTH. MULII-WIDE FLOOR SHOWN SL M11D FOR CLARITY L2V V V 4' 24' STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS (SEE TIE -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXIAN SPACING ALLOWED). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A MAXIMUM OF V-0' (24') FROM EACH END OF THE UNIT. FOR TRIPLE WIDE AND LARGER UNIT DESIGNS, INSTALL ALL TIE -DOWN STRAPS AS SHOWN IN THIS DETAIL NOTES: 1. LARGE OPENING = ANY OPENING WIDER THAN MAX TIE -DOWN SPACING ALLOWED. 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TE-DOWN SPACIW SO LONG AS, THE AVERAGE SPACING ( (A+B+C) / 3 ] DOES NOT EXCEED THE MAXIMUM DE -DOWN SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DON LOCATIONS. 4. SEE AD-M-0001 FOR ADDITIONAL REQUIREMENTS C. D, �iL . IY IENEa703571 ' , 5TA �jOF : Q: IV. Ile NAL E_...�. BY ItId 5 10 DEVICES ARE CERTIFIED BY OTHERS JACOBSEN HOMES NOTICE BY: DATE REV. LETTER: ��� AND O,,,,,� „M C.L.Y. 6-1-95 TAouNN- PfOPWARY. AND OWWR.L DRAWING TITLE AM PROVEED TO rME A P.O. BOX 368 MAT RIALS OfJACOBSENMNWACTUM TYP. MULTI —WIDE T/D „ SAFETY HARBOR. FLORIDA 34695 K�F fdt � RJFKS uD MST K DRAWING NUMBER PHONE (813) 726-113a IVT CAI MTK NO SEA ffi011 OHM AD—TD-0310 "/'A SINGLE WIDE TIE -DOWN IPULL DOWN TIGHT TO GROUND ANCHOR DETAIL 'A' ZONE I TIE -DOWNS SEE DETAIL - 'A' SEE DETAIL - V - MARRIAGE WALL - OPENING TIE -DOWN IEQUIRED AT OPENIN, ONLY. OPTIONAL AT OTHER LOCATIONS.) FRAME TIE -DOWN DOUBLE WIDE TIE -DOWN NOTE: C SECTION MARRIAGE WALL SIMILAR TO I OPENING TIE -DOWN I SINGLE WIDE (RONLY. EOPTIONAL D AT �ATOS FRAME TIE -DOWN I OTHER LOCATIONSA NOTE: A k B SECTIONS SIMILAR TO DOUBLE WIDE TIE -DOWN TRIPLE WIDE TIE —DOWN SEE DETAIL - 'A' SEE DETAIL - 'B' TIE -DOWN STRAP SINGLE HEADED GROUND. ANCHOR (WHEN MARRIAGE WALL TIES AND FRAME TES ARE LOCATED AND SECURED TO THE SAME GROUND' BUCKLE WITH 2O251 FOR, A DOUBLE HEADED GROUND ANCHOR MUST BE USED) tY MINIMUM ALL GROUND ANCHORS MUST BE LISTED TO CARRY THE LOADING IMPOSED BY THE RE -DOWN STRAPPING (315o LBS. MAXIMUM FOR EACH TIE -DOWN STRAP CONNECTED). DETAIL 'B' TYPICAL TIE -DOWN STRAP (1 1/4' X .oV MINIMUM ZINK COATED STEEL STRAP. OR EQUAL WITH 315ot CAPACITY MINIMUM) 47zs r UL.T,,,, ,, LpA1.p 0qr-AclTy �IIIIIffff NOTES: QJQ ZO .a_ 0__ DAPIA APPROVAL' �..... I 1. SEE DETAIL 'B' PAGE 4 NOR MARRIAGE WALL �4% �Lo, . '.orlC;q'•.F�, OPENINGS GREATER THAN 49INCHES. & UP To I7' 6" TTe1BVT : ri T4``'; �: APPROVED BY 2. SEE DE -DOWN SPACING CHART ON PAGE 2 EDR s P� + X.). COMM 2 ANCHOR AND TIE -DOWN PLACEMENT. * 4EC ' 3. SEE DETAIL 'A' PAGE FOR TYPICAL i-BEAN PIER CONSTRlIC110N �' STATE OF 11b 9C� iNC E AN mm JACOBSEN HOMES THESE sPECIRCAN11oG 73uro DRAMM ARE BY. RR DAZE' 10-31-95 REv �nER ■ CWHAL. PROPRIETARY. MW CCNF10E1 IA DRAWING TITti P.O. BOX 368 MATERIALS of JACOM MATAIFACIMIC ZONE I TIE -DOWNS W_ SUCH MATERIALS ARE FR%= TO THE SAFETY HARBOR, FLORIDA 34695 REOPpiT FCR gm PII"m AND Mi1ST If DRAWING NUMBER PHONE (813) 726-1138 107 COIiOQ nk RO SEOV ntm omm AD-Zl -0001 74 PACE 7- 75 ZONE I TIE —DOWN PLACEMENT TYPICAL I -BEAM TIE -DOWN MAIN FRAME I -BEAM `SFE N01E /1— � — MAIN FRAME I -BEAM END CENTER A NG. .I CENTER CI I GI SPACING I I DOUBLE WIDE TIE—DOIYN PLACEMENT END CENTER CENTER CENTER CENTER CENTER END ^•+••• TYPICAL I -BEAM TIE-DOYN ..V .Yn41N .7PA41\U YAWY MAIN FRAME 1-BEAM -SEE NOTE /1� `SEE NOTE /1-/'- MAIN FRAME I -BEAM MAIN FRAME I -BEAM END CENTER CENTER 1END SPACING SPACING SPACING ce C., co ce TRIPLE WIDE TIE —DOWN PLACEMENT NOTES: ENGINEER, DO , DAPIA APPROVAL T. SEE DETAIL 'B' PAGE 4 FOR BLOCKING AND ANCHORING OF �. ,.•fv� Cgj,•.•'L �„ APPROVED BY MARRIAGE WALL OPENINGS WIDER THAN 49 INCHES. %` No. 0045434oil* ON 14 STATE OF + 1 .•'�,` 10�; : �`'��,� cua,aanlNowmsw®vms ..N�� �,. JAC O BS EN HOMES THESE SPEtlI FlCA TMSS Nomua DRAWRM ARE ' vol i0 �} RR DA1�' 10-31-95 REV. LETTER ■ WGINAL PROPRIETARY. AND COWWTA DRAWING TITLE. P.O. BOX 368 UATERIAIS OF JACOM UWACTMINc AM PROMM 70 THE TIE -DOWN PLACEMENT „ SAFETY HARBOR, FLORIDA 34695 If TOR A� RNMRS NO UM BE DRAWING NUUBER PHONE (813) 726-1138 JUTCOWWRk AND SECRET TRW OTTERS AD- Zi-0020 76 ZONE I INSTALLATIONS 1. FOR HOMES LOCATED IN ZONE I, FOLLOW THE MANUFACTURER'S ZONE 2 INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF LONGITUDINAL ANCHORS. 2. FOR HOMES LOCATED IN ZONE I ONLY, FOLLOW THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF SHINGLES AND/OR LAP SIDING. FOR ALL OTHER WIND ZONES REFER TO DETAILS IN THE SET-UP MANUAL AND/OR THIS ADDENDUM. i 6Y a [t/. FEB 0 1 W INC. JACOBSEN HOMES YKSC �`AM DRAW= � ��� �•: u"" M.T. 2-1-00 �.. K.« oaiarw, MRO NAIr. " CCRil0EN1At ""nI= °" 1 DRAIMWC 11T1E: ZONE 1 INST. /� ,• P.O. BOX 355 XS W P'"'"'r D TO r4 SAFETY HARBOR. FLORIDA 34695 KCPMR RR MON I�R OM AM I Y U DRAW NUMBER: PHONE (727) 726-1138 Hart COMM Am Rat, FROM CUM - AO-Z1-0100 77 ADDENDUM FOR INTERSECTING UNITS MAIN UNIT /DORMER I \ . LONGITUDINAL TIES ONLY REQUIRED 0 EA. HALF OUTSIDE BEAM INS END, EXCEPT FOR ZONE 3 EXP.'0' THEN 2 RECUIRED EA. HALF (IE. 01iE EA. BEAU, ETC_.) VERTICAL AND DIAGONAL TIES INSTALLED ALONG THE SDEWALLS SAME AS THE MAN UNIT. VERTICAL TIES AT CENTER LINE RECUIRED ONLY AT COLUMN SUPPORTS PER DOUBLE MOE CONNECTION REOUIREMEHTS. 24' MAXIMUM SPACING TO FIRST SIDWALL TIE FROM EACH END OF THE UNIT (SAME AS TYP. DOl8 WIDE TIE -DOWN REOUIREMENTS). 2 LONGITUDINAL TIES REOUIRED AT EACH HALF IRIS END ONLY. MAXIMUM PIER HEIGHT FOR VARIOUS ZONES (REFER ALSO TO SIDEWALL TIE -DOWNS MAXIMUM HEIGIIT} ZM1 7 ME_3 EXPOSURE 'C' 90' 56' EXPOSURE V 39' 46' CONNECT THE TRIPLE WIDE OR QUAD. WIDE SECTION(S) TO THE DORMER AND )LAIN UNIT PER DOUBLE WIDE MARRIAGE LINE DETAILS AS OUTLINED IN THE SET-UP MANUAL (EXCEPTION: NAILING ONLY IS REQUIRED AT FLOOR CONNECTION. NO STRAPS ARE ' REQUIRED TO BE INSTALLED ACROSS THE FIAOR CONNECTION AT THIS AREA.) 01%111111181",//''i S NOTEN ROV •••.., DAPIA APPROVAL J �� •..�G�E 1. FOR QUAD SECTIONS. EACH IDOUBLE SECTION' OF THE UNIT SHALL BE DESIGNED ' Q' NO.APPROVED BYE,,,.. INDEPENDENT OF THE DIRER STRUCTURE (IL: SHEARWALLS, TIE-ODWNS, RIDGE- /ENEA70357 '• BEAMS, COLUMN SUPPORTS, ETC.. ARE CALCULATED FOR EACH MULTI -SECTION.) cJUN 1 5 S A�J IF•'�c, �In' C ' �'49�.c''• �/��j'�AT•�'• ���.�� rtaw�wrv�WmwE ,.EN NOTICE DRAWN BY: DATE REV. LETTER: JACOBSEN HOMES n+ESE SPE011CA710N5 AND DRAMNGS ARE C.L.Y. 5-16-95 MONAL PRfJ WARY, AND COWIDUITIAI DRAWING TITLE P.O. BOX 368 M uArE� AK �z>m TO ADDENDUM —INT. UNITS SAFETY HARBOR, FLORIDA 34695 KCF0 T Fat 9'EEIY P{/fM MU MW BE DRAWING NUMBER PHONE (813) 726-1138 IVT CWMTIAL AM SECKI FRCH 0DEM QUADADDI 78 ALT. ROOF ASSEMBLY FOR MULTI—WIDES CENTERLINE COINECTIOH FOR QUAD UMTS IS THE SATE AS FOR THE MAIN UNIT (REFER TO SET-UP DETALS� 30 CA. GALV. STEEL STRIP INSTALLED OVER MATING LINE JOINT (SEE PLAN NEW BELOW) ROOF PFRO M RAL OR ROM BEAN CROSS-SECTION 30 GA. GALV. STEEL STRIP 8' X LENGTH OF ROOF SSECTIONS MAY BE OVERLAPPED 2 MIN.) W/STAPLES AS SHONN. INSTALL ROOF CAP PER SET- UP YIN. OVER GALV. STRIP. (SEE NOTE 1) 31 X S' LAG SCREWS 1B' O.C. (ZONES 2 8 3) STAGGERED �— 30 CA. GAIN. STEEL STRIP SECURED WITH 7/16- X 16 GA. STAPLES FULL PENETRATION NTO DECKING 2 ^ o.C. IIAX. SPACING (TYP.) — ENGI``7' 0 • oO� ���DAPIA APPROVAL: ST 1. 30 GA. CALV. STRIPS USED MAY BE WIND DEFLECTORS • %` : ' �i.G% F9F ��?i ��'.f+ N D 8Y REMOVED FROM ROOF IN DRUM CONDITION � Q No. O • (EXCEPT FOR STAPLE HOLES). ? ENE8703571 .U) 1 5 STEEL STRIP MAY BE CONTIM10U5 OR PIECED. A 2 BE P SHINGLES IN THE DORMER AREA OF THE MAIN UNIT MAY �•� = INC, SHIPED LOOSE AND INSTALLED ON SITE AFTER '• -` (, THE UNITS HAVE BEEN ATTADO TO PREVENT ANY O,�'•. /ND(9e►�" .: ��: TRANSIT DAMAGE AND TO ENSURE THE SHNGLES LINE-UP �•i� F ���• � � FROM ONE SECTION TO THE NEXT.,�i���S�� • • •. ENG����` NOTICE: N1I lamsolat. DALE REV. LETTER JACOBSEN HOMES msE sKulcA n Afro omwa C.L.Y. s-ts-95 GR OMAL. PAOPRKIARY. AM GON1WTIAL DRAWING TITLE: ALT. ROOF ASSEMBLY Ito P.O. BOX 368 YAT011K' Di m MANINACB ICING NG 9J01 YATLi$KS ARF PRONGED TO TIK SAFETY HARBOR FLORIDA 34695 xww Rx 9E171C pjFOS5 AN) am K DRAWING NUMBER PHONE (813) 726-1138 XIPT 02#MT K NO SEOKT n= OTIM QUAOAOD2 79