CENTRAL AIR SYSTEM
Page 1 Residsntlal Heat Lass and Heat Gain Calculation 6/27/2018 In accordance with ACCA Manual J Report Prepared By: A Rd stems Inc. ... v,.. f,� x:.g�"a �{, ? N For: BtJffa �IJF"iY�l�4J 923 Nettles BY Jensen beach fi 5t. Lucre Coutn it Design Conditions-F,ort fierce - Indoor. Outdoor. Summertemperature: 70 Summer temperature: 90 Winter temperature: 70 Winter temperature: 42 Relative humidity: 55 Summer grains of moisture: 127 Daily temperature rangeMedium Building. Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Duct 2,515 0 2,515 1,355 Floors 1,084 0 1,084 1,926 Walls 1,182 .0 1,182 1,403 Ceilings 2,043 0 2,043 1,589 People 1,500 1,160 2,650 0 Fireplaces . 0 0 0 0 Misc 1,200 0 1,200 0 Windows 7,714 0 7,714 3,771 Doors 780 0 780 925 Glass, doors 0 0 0 0 Skylights 0 0 0 0 Infiltration 11261 28612 3,873 3,932 Whole House 19,279 3,762 23,041 ( 2 tons ) 14,901 FILE COPY HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load wtommna are enumatncnts, amw bads may vary dotoweew wd=nu w e fw=es.