Loading...
HomeMy WebLinkAboutPERMIT WORK SHEETPERMIT l41, ORKSHEET I page -I or � PERMIT NUMBER -`EDDIE=GRUNDEL New Home ® •Usem d Hoe installer=== Lrc�_ae-#___IH11_18467_ - - _ orn-e ins•tailed-to_tlie-.Manufactur_er's_ Installation Manual Address of home 18 NETTLES BLVD Home is installed in accordance with Rule 15-C 0) beirig'instafled "� Sirigle•wide Wnd Zone ll 0' Wind'Zone_III ®C Manufacturer Jacobsen Length x width 20 X 35 Double wide ® 'Installation becal # TBD CD` > ' ® NOTE: e g wide fill out one half of the -'blocking plan Triple/Quad Serial # TBD M ,, if home is a frl l9 or q uad wide sketch in remainder of home u I understand Lateral Arm Systems oannot be used on any home (new or used) PIER SPACING TABLE FOR USED HOMES where the sidewall ties exceed 5 It 4 lh'. Installer's initials EG Typical'pier spacing lateral 2', . 61 ���/// Show locations of Longitudinal and Lateral Systems longitudinal (use dark line's'to show these locations) F-1 El --I....s--------------^-------------i..�.~-- --- Gn�� i• marriage wall piers within 2' of and of home p r Rule 15C , Li Li Li Li -r-r^r-1--1-1-1`r-r-rti-n-T-r-r-rrri-r-r-r-r-1--.-n­ 7-r-r-r-r- I I I 1 I I I 1. I I I 1 1 I I 1 1 1 I 1 1 1 1 1 1 1 I 1 I I 1 I I I I I I r-r-f-+n i-7-r•-r-r-j -,--1-T-r-,--� -i ^I--7-1.-'r -I--I-!-7-r-� -I--1--I- �- �-,--r-I 1 1 -i- -1_L_.L_L._1_J_J_1_L,_L_L_I_J-.J._ i.,L_ L _I__I_J_ J_ A_L_L._L I_.-1_J-.1_L_L_I__I ... I I 1 , 1 , 1 f 1 1 L-L_1_..,_J-.;_L_L_L_1-.i-.i-1-Y-L-f--I-.-1--1-i-L_F_L_I_...1-.,-+_L-.L-1...-1_.J-J-.i-7--1--L _I I I 1 I I I 1 I I 1 1 1 1 I 1 I 1 I I 1 I I 1 1 1 1 1 t 1 I 1 1 1 I I I I 1 ,..-I--,--1_y-T-C-r_1-_I-'1^l_•T-r_r,-r-1-..,-l-T-.p-1'-1--1_-1_'1-7-r -r _f ��_-1-•t-T_T-r_r _I. r-r-r'I--1-'1-7-T-r-r-I--1-'7-•T-r-r-r-1--1-'j-T'-r-r-r-I r-r-r-,-'1-; -r-r-I`-I--,- ;-7-;-r-,--,--,- i' �-T-r -r-i -1- �-•7-r-r-r-i-1-•1-7- � -r-r-I 1 I I I I 1 , , 1 I I 1 I I 1 1 1 { 1 I I I 1 1 1 I L_1__I_J_J-i_L_L_I--1_J-J_1_L_'L_L_I_J-J-1_L_L._I__I_ J- J_ 1_L_L._L _I-J-J_1_L_L._I- I 1 I I I 1 1 1 I I I I I 1 I 1 L_I-J_.1-1-Y_L-L_I_J-.1-+-L.-I.-L_I--I--+_Y.L_I..-1_J_.1-+-{-L-L-1-J_J-.1_Y-4-1--I_J 1 1 I I I 1 1 .1_y_+,-*•-!--1--1-"1-�-t-Y-r_1--I-'y-7-t-r-{'-r-1-'�-'I-�'-r-1--1--�--1-'1-4-r-r-r-1--1 Load bearing capacity Fsiz er size (sq in) 16" x 16" (256) 18 1 /2" x 18 1/2" (342) 20" x 20" (400) 22" x 22" (484)- 2411 X 24" (576)" 26" x 26" (676) 1000 ps 1500 ps ps 2500 ps ps ps x mterpolatea rrom Kule IbU- I pier spacing tame. PIER PAD SIZES 1-beam pier pad size 17X22.5 Perimeter pier'pad size 16X16 Other pier pad sizes (required bythe'rnfg.) Draw the approximate locations ofmarriac wall openings 4 foot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foo and their pier pad .sizes below. Opening 1&4 2.&3 POPULAR PAD SIZES �IIIIIIIIIIIIIIIIIIIIIIP�:3'i��� � ANCHORS 4ft X' 5ft FRAM E TI ES ,within 2' ofend of home X ,spaI ed'at5'4"ocx — TIEDOWN COMPONENTS OTHERTIES 11 Nuniber (Longitudinal Stabilizing Device (LSD) Sidewall Manufacturer OLIVER 'Longitudinal Longitudinal Stabilizing Device w_ /Lateral Arms Marriage wall Manufacturer Shearwall Pier pad size. 17X22.5� 23 x31 PERMIT WORKSHF-F-T PERMIT NUMBER ' page z o>i z POCKET PENETROMETER TEST The pocketpenetrorrietertests are rounded down to 1500 psf or check here to declare 1000 lb. soil without testing. X 150(X 150( " X 150( POCKET PENETROMETER TESTING METHOD 1. Test the perimeterofthe home at locations. 2. Take the reading at the depth of the footer. 3. Using 500 lb. increments, take the lowest reading and round down to'that increment. X 150( X ;150( X 150( TORQUE PROBE TEST The results of the torque probe test is 289 inch pounds or'check here'if you are declaring 5' anchors Without testing . Atest ,showing 275 inch pounds or less will require 5 foot anchors. Note: Astate approved lateral arm system is being used and 4 ft. ariohors are allowed at the sidewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and -where the mobile home manufacturer may requires anchors with 4000 lb_ holding capacity': EG Installer's initials ALL TESTS MUST BE PERFORMED BY LICENSED INSTALLER Installer Name EDQIE GRUNDEL Date Tested Electrical onnect electrical conductors between multi -wide units, but notto' the main power ource. This includes-the.'bonding wire between mutt -wide units. Pg. Plumbing onnect all sewer drains to an emsting sewer tap or septic tank. Pg.' onnect all potable water supply piping to an e)asting water meter, water tap, or other :aeno.+rie�}nroaorcnr+nlvevc+emc Pn — --- - - — -- — — --Site-Pre paratiqn. - -- - - De6ris and' ' nic material removed YES Water drainage: Natural Swale Pad X Other Fastening m u i wide units Floor: ;Type` Fastener: ' Length: 6" Spacing: 24 .Walls: Type Fastener: LAG Length: 1' Spaciiig:24" Roof Type Fastener: GALV Length: Spacing: For used homes a min. 30 gauge, 8" wide, galvanized metal strip will be centered over the peak of the roof and fastened with galv. roofing nails at 2" on center on both s ides of the centerline. Gasket (woothorproofing roquiromont) I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result ofa poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initials EG Type gasket FOAM Pg. Installed: Between Floors Yes X Between VValls Yes X Bottom of ridgebeam Yes X Weatherproofing The bottomboard will be repaired and/or taped. Yes X Pg. Siding on units is installed to manufaoturer's specifications. Yes X Fireplace chimneyinstalled"so as nottoallow intrusion of rain water. Yes X Miscellaneous Skirting to be installed. Yes X No Dryer vent install edoutsideofskirting. Yes X N/A Range downflow vent installed outside of skirting. Yes .�— N/A_ Drain lines 'supported at 4 foot intervals. Yes x_ Electrical oross'overs 'protected. Yes X Other Installer verifies all information given with this permit worksheet is accurate and true Lased on the manufacturer's installation instructions and or,Ru a 15C-1 & 2 Installer Signature