Loading...
HomeMy WebLinkAboutSET-UP MANUAL ADDENDUMSET-UP MXINUAL ADDENDUM JACOBSEN HOMES 600 PACKARD COURT 1SAFETY HARBOR, FLORIDA (727) 726-1138 NOTICE These specifications and drawings are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific purposes and must be kept confidential and secret f tjieVw 0-� r% nN REV-01 /10 ALL HOMES SET IN FLORIDA MUST COMPLY WITH DMV RULE 15C EFFECTIVE MARCH 29,1999 For information on 15C- contact the Department of Motor Vehicles 850-413-7600 .NOTES: ADDENDUM EXTERIOR HEATING/COOLING DUCT DUE TO THE NEW THERMAL REQUIREMENTS INSTITUTED BY HUD, THE INSULATION VALUES OF THE MANUFACTURED HOME HAVE INCREASED. IT IS NOW NECESSARY FOR ALL EXTERIOR DUCTS INSTALLED ON JACOBSEN HOMES HAVE A MINIMUM R—VALUE OF B. ALL HEATING AND/OR COOLING SUPPLY AND RETURN DUCTS EXPOSED DIRECTLY TO THE OUTSIDE AIR, SUCH AS UNDER CHASSIS CROSSOVER DUCTS OR DUCTS CONNECTING EXTERNAL HEATING, COOLING OR COMBINATION HEATING/COOLING APPLIANCES SHALL BE INSULATED WITH MATERIAL HAVING A MINIMUM THERMAL RESITANCE OF R=8.0, WITH A CONTINUOUS VAPOR BARRIER HAVING A PERM RATING OF NOT MORE THAN 1 PERM. WHERE EXPOSED UNDERNEATH THE MANUFACTURED HOME, THE DUCT SHALL NOT BE IN CONTACT WITH THE GROUND, / DUCT SUPPLY OR RETURN HOLING SSOVER USE MINIMAL AMOUNT OF DUCT. LIMIT DUCT USAGE TO REDUCE THE AMOUT OF BTU/HOUR LOSS. DO NOT OVER BEND OR CRIMP FLEX DUCT, THIS WALL RESTRICT THE AMOUNT OF AIR FLOW THROUGH THE DUCT. USE STRAPPING OR OTHER MEANS OF SUPPORT TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. PLACE STRAPS AS NEEDED TO SUPPORT DUCT (DO NOT RESTICT AIR FLOW BY OVER TIGHTENING SUPPORT STRAPS). ALSO SEE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR DUCT INSTALLATION AND SUPPORT. DAPIA APPROVAL 'PROVED BY ` 419im 1 5 m (NC JACOBSEN HOMES NOTICE DRANM BY: DATE: REV. LETTER THESE sPEanutwNs AND oRAwNcs ARE C.L.Y. 5-30-95 CF40NAL. PROMMARY, AND CONFMT{AL DRA►ANG TITLE: MATMALS OF JACOBSEN MANUFACTURING EXTERIOR A/C DUCT P.O. BOX 368 MG sxm YAmms AM FRONDED TO 7NE SAFETY HARBOR. FLORIDA 34695 RECM1 FOR SPEOFIC PJPOSES AND MUST BE DRAMNG NUMBER: PHONE (613) 726-1138 JUT CDWMTIAL AND SEDU FROZE OHM AD-AC-0001 2 ADDENDUM WHOLE HOUSE VENTILATION SYSTEM YOUR HOME HAS BEEN EQUIPPED WITH A 'WHOLE HOUSE' VENTILATION SYSTEM. THIS SYSTEM HAS BEEN DESIGNED TO MEET ALL THE REQUIREMENTS SET FORTH BY THE UNITED . STATES DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. THE WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED (BY HUD) TO EXCHANGE AIR DIRECTLY WITH THE EXTERIOR OF THE HOME. THE PURPOSE OF THIS SYSTEM IS TO GIVE THE HOME OWNER THE ABILITY TO INTRODUCE FRESH OUTSIDE AIR INTO THE INTERIOR OF THE MANUFACTURED HOME, INSTEAD OF SIMPLY RE— CIRCULATING THE SAME OLD, STALE AIR THROUGHOUT THE HOME, THUS IMPROVING THE INDOOR AIR QUALITY. THE SYSTEM INSTALLED IN YOUR HOME HAS BEEN DESIGNED TO GIVE YOU COMPLETE CONTROL OF WHEN AND HOW THIS SYSTEM IS USED. YOUR HOME IS EQUIPPED WITH A FAN THAT WILL EXHAUST STALE INDOOR AIR (TO THE EXTERIOR OF THE HOME). THIS FAN IS SWITCH CONTP.OLLED AND MAY BE MANUALLY OPERATED. TO DI-CONT!"!UE USE OF THIS SYSTEM, SIMPLY 'TURN OFF' THE SWITCH THAT CONTROLS THE FAN. NOTICE TO HOMEOWNER Whole house ventilation switch You will be able to locate the switch that controls this fan by locating the switch that is labeled -WHOLE HOUSE VENTILATION. (See AD-AC-0100) NOTICE: DRAWN BY: JACOBSEN HOMES TNESE sKoncooNs ANo ORAMIN6S Am C.L.Y. ■ O NN4. FROPRKTART, A" aoN MM4L DRAVMG iITM P.O. BOX 368 YATMALS OF JACOBSEN LIMUFACr W0 „ SAFETY HARBOR, FLORIDA 34695 AEA fOR gr� gJM3 NO NAK PRW= MI K SWING muyBER* PHONE (813) 726-1138 PUT CMUNDA APO SEM 11= ORM APPROVED BY 1N14SAY INC. me cm 1 FC6 DATE: 9-28-55 1 REV. LETTrR: W.H. VENT. SYS. B AD—AC-0100 3 EACH SIDE OF CENTER LINE PER TABLE BELOW: INSTALL WOOD SHIM AT ALL LAG FOR GAPS IN FLOOR SYSTEMS TO 1/f, INCREASE LAG LENGTH 1' NDS01 LOCATIONS FOR LAG SCREW TO GO THROUGH AND TO KEEP CONNECTION AND FOR GAPS TO 3/4% INCREASE (ALL ZONES) TIGHT. (SEE NOTE 2) LAG LENGTH 1 1/2'. (ALL DFOWRES) 30 GUL STRAP FASTQED M/ MMOM NUMBER OF FASTENERS REWR D r90 TALE EXPo6K 3/6' X 3 1/r LAG SCREW 7/11' X 16 sti STAPLES WO 2GHE E*VSRtE MA70LAx1 SPACNG MAXLRN SPA M131' X 1 1/Y MAU 7/1r X 16 GA. StV%ES 'C' Ilr OC. 2 1/4' O.C. T: 3 S 2 2 b' 1r QC. 1 7/8' 04 b' 4 7 1r QG Y 4 7 3 3 b' 16' ac 1 1/2' OLC. b' S e NOTESe ENDW APPROVAL DAP1A APPROVAL APPROVED BY 1. 1' MR PETETRATIDN 15 REMO OM STAPLES FOR MIK 0.01r STRAP. L 11000 Sams TD BE WrED FROM SPF p MIL OR BETTER. oor ON rl Revised May 24 , 2006 (r X 4' X GM ODTH WL SZE) .� �3 .016 IINC. (OSB oR PLYWOOO MAY BE USED 1F WDOISS EQUALS GAP MDTi1-4'x4'COLM, ohn C. EIOA on, Pb. 3. 10r MAXBAAI SDEDALL NEW. , IK2 En n riK�, E'T.". EDO FEDEML MANUFACTURED MDYE CONSTRLNCTION AND SAI ETr STANDARDS 4. SEE OT1E11 DEL%S FDA SEALM FLOORS FOR AIR KLTRA➢OIL JACOBSEN HOMES ,OM>�T°�MA�AN DRAIN BY. M.T. DATE: 05-22-06 REV. lLl1ER DWI P.O. Box ace SAL• PF"FAu,<r, so COFEUM MAWAM3 OF 4ACOMM UNWACA M6 MAIMU AR PFV#M TD IK DRAW TITLE M/W FLOOR FASTENING SAFETY HARBOR. FLORIDA 3095 PHONE (513) 726-1138 Nc 3101 KOM IU1'.PM PJF= AO MW HE Un CMF OUL AO OW Fuel of M DRAWX WIDER: R: AD-FA-0001 ADDENDUM- MULTI -WIDE. UNIT WALL FASTENING ENDWALL - NDS01 NoTms 1. FASTENING REQUIRED ONLY AT MARRIAGE LINE OF EXTERIOR WALLS. .131- X 3 1/2- MIN. NAILS 8. O.C. MAX. SPACING, STAGGERED FROM SIDE TO SIDE (TOE -NAILED). MARRIAGE LINE DIGNM NI MMVAL BAP1A APP110Ok APPROVED BY 0 00*r Revised S ?'� ab AMay 24,2006 Jahn C. Doeden, p.6. INC. K2 Eno" wring. Ina. FROEMLEYMui.C7U11EO NOYE COMSTR1K.ilOR MO SAFETY STM )AROS JACOBSEN HOMES > »►"�i o mum Im 0RA1N P. M.T." 05-22-� xE� `� EAK3SAFE7Y P.O. Box 36B �.�,�,� mhum u a i1=m MMMACPAW W. 20 VAIM s Ai[ lRO=1011t WAMW 11� M/W WALL FASTENING B HARBOR. FLORbA 34695 �m NO K ��C � PHONE (813) 726-1138 IE mamt m mn�m anm AD-FA-0010 5 ADDENDUM MULTI —WIDE ROOF FASTENING 30 -GA. GALV. STEEL STRIP --<- SECURED WITH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING (SEE CHART ON AD-FA-0001 MAX SPACING). -LAG SCREW SET BACKS FOR TRIPLE WIDES FOR DOUBLE WIDES� TRIPLE WIDE ROOF LINE INSTALL LAG SCREWS I I AT A 45' ANGLE STAGGERED` ROOF PERIMETER RAIL' OR RIDGE BEAM (FOR RIDGE BEAMS SEE NOTE #4) CENTER LINE OR MATING LINE OF TRIPLE WIDE UNITS —.30 GA. GALV. STEEL STRIP T X LENGTH OF ROOF (SECTIONS MAY BE OVERLAPPED 2' MIN.) W/STAPLES AS SHOWN. INSTIL. ROOF CAP PER SET- UP MAN. OVER GAL STRIP. (30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION, EXCEPT FOR STAPLE HOLES.) PANVIw f3/6' X 5' LAG SCREWS ••LAG SCREW MI BACKS (2 1/4' SM001H SHANK) FOR DOUBLE WIRES -(- SEE CHART ON AD-FA-0001 FOR TRIPLE WIDES FOR MAXIMUM SPACING 21 4 *34*1 4' TO3 4' GAP_ CROSS-SECTION J �- INSTALL WOOD SHIM AT ALL LAG FOR GAPS IN ROOF SYSTEMS OR FLOCATIONS FOR LAG SCREW TO GO TO 1 INCREASE LAG LENGTH 1' THROUGH MO TO KEEP CONNECTION ILO FOR GAPS TO 3/4', INCREASE TIGHT. (SEE NOTE 2) NOS01 uG LENGTH 1 1/2'. REF CAL.C. PG. (ALL ZONES) CROSS-SECTION A GAP) c WA- 91.01- 91.07 (ALL EXPOSURES) NOTES: EHp W APPROVAL• DAKA APPROVAL: L 2 1/r' WL PDIEM101 100 RECOW HOW 5 REOUrii! FUR LAB SUM 2. WORD 2W TO BE RIPPED FROM SPF p MR OR LETTER Ic X C X WP WDTH MR SM APPROVED BY 1T 09 OR PLYMOOD MAY BE USED F MWESS EQUALS GAP M D1 4' X C UK Sid s. / ! Q Revised ON May 24 , 200 6 I SEE OM DETALS FOR CMFLLIN ROOF KiMCTOL John C. LiOAOe�. P L-. I N C 4. *0 IWALLM A LAG WO KM A RIDGE BEAM FitST-MIL'A 31e [1fAR U K2. EngW-*ern Tg, Inc . FEDERAL MANUFACTURED HOME HOME MUM THE FIRST MM BEAM. SECOF"RLL A 1/4 HOLE THROUGH TIE CONSTRUCTION AND SAFETY STANDARDS RECG%M RIDGE 1M➢W FOR THE THREADED PM70 OF LAC S" DIM DINS ARE FOR 31lr LAG SMI MS OILY. S lQr HA70 M SE MALL HEIGHT. JACOBSEN HOMES Nomcm gm womc ws AND mA-= ARE DRAYN BY: M.T. DATE os-22-06 REV. 1ETot P.O. Box 36B O wKq. FRWIETM r. AND aawmom#L WATE NS Or AAaoM �ACnIF" WAYM Ink M/W ROOF FASTENING AIc sn wmws m Pro= To THE °�'�'c "�"�'t PHONE (81i3j 7i6-1i3 Lam. a� ono as AD-FA-0020 METAL ROOF RIDGE CAP DOUBLE WIDE UNITS ONLY PLAN VIEW 29 GA MIN. GALV. STEEL. RIDGE CAP COVERING LENGTH OF ROOF (MUL f OVERLAP AT %AM) CENTER OR MATING LINE SECURED WITH #8 X 711C HEAD X f FULLY THREADFA SCREW AT EVERY RIB (AND ON BOTH SIDES OF RIB VAT" END ZONE) I• I I I \J, I R X 7/16- HEAD X Y / ILLY THREADED SCREW RIDGE CAP -� i (NO MORE THAN It O.C.) I I � j I I Cl a 1 I 1 B m_ ASPHALTIMPREGNATED SEALER STRIP BETWEEN RIBS I OR CLOSURE STRIP RUNNING 1 1 ENTIRE LENGTH OF ROOF I I METAL ROOF PANELS STOP I , APP. -3" FROM CENTER LINE It I , ' M GA. GALV. STEEL STRIP Ref: EX-13-0051 and 5. X LENGTH OF W (SEE AD-FA-0020) AD—FA-0020 SECURED 97H 7/160 X 16 GA. STAPLES FULL . PENETRATION INTO DEO(ING (ALL ZONES) (SEE CHART ON AD—FA—OODI MAX. SPACING) (ALL EXPOSURES) . luArno. APPROVED BY SEE OTHER DETAILS FOR CONNECTIONS BETWEEN SECTIONS ep STANDARD 7/16- O.S.B. (24/16 INDEX) ROOF SHEATHING. Vgd;)-ZS� ON P1 IN 10,2008 METAL PANELS ARE 29 GA. MIN. STEEL WITH V O.C. RIBS�. SCREWS HAVE A NEOPRENE WASHER FOR WEATHER PROOFING AND -G. Doadoi +s FEOEAAL W!lgIFACflllEo xorE TO HELP AVOID OVER DRIVING. IF SCREW IS OVER DRIVEN g, InG coMsrnucnoH AND SAFETY sTMOMDS ANOTHER SCREW MUST BE ADDED BESIDE THE INEFFECTIVE SCREW (DO NOT REMOVE OVER DRIVEN SCREWS) 3333 JACOBSEN HOMESNOP= WAN W. D.M.T. DAZE 08-25-08 REV.` olm T gmmws AID w1um oR�u. PROPAEURI►. AID ca�xiul. DRIWYI6 TOtE Wium of �usarFAci m METAL ROOF RIDGE CAP fftP.O. BOX 36B Rm am YAiH01115 Al1E Form 70 TIE SAFETY HAt IL FLORIDA 34695 WRIT FtR YM A1Ms M M IK DBAYDID AAl�it PHONE (813) 726-1138 an m,Fmim me saw ma umm AD-FA-0021 7 ADDENDUM MULTI=WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING \ (SEE AD—FA-0020 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 15# FELT UNDERLAYMENT Is MULTI —WIDE ROOF LINE BEAD OF ROOFING CEMENT RECOMMENDED EACH SIDE DAPIA APPROVAL• PROVED BY 11H INCJIM 0�11ACTUM "m lo" MO SAfL715wom NOTICE DRAWN BY. C.L.Y. DATE. 6-5-95 REV. LETTER. JACOBSEN HOMES THESE sPEOnCA7OHS AND DRAW= ARE ■ MONAL, PROPRCIMY. AHD CANIMTK DRAWING TITLE P.O. BOX 368 MA70 Ws CF dACMSEN NWAC7MG M/W ROOF SEALING „ SAFETY HARBOR. FLORIDA 34695 Flova rGR SKCM ROW "KW BE DRAWING NUMBER PHONE (813) 726-1138 IQVT OOHF10E1ITK AID SE001`10 OO+E M AD-FA-0025 8 ADDENDUM MULTI -WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING (SEE AD-FA-0020) • 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES - LOW SIDE 6" STRIP ROOFING CEMENT REQUIRED OVER EDGES -HIGH SIDE / 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT (2 BEADS REQ'D HIGH SIDE 1 BEAD RECOMMENDED ON THE LOW SIDE) DANA APPROVAL NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS AP PROVED BY REMOVED FROM ROOF IN ORIGINAL CONDITION JUN I 5 1995 (EXCEPT FOR STAPLE HOLES). qWvimosomnvownACTUFMNOW INC. J AC O B S E N HOMES NOTICE: TKSE SPECIFKJ IMS MD DRAWNIS AM DRAW BY: • C.L.Y. DATE: 6-`J-9S REV. LETTER: WONAE. PROPRIETARY, AND CONMENTI& YAIERIALS W JACOM MWJACtIRING DRAMLNG nTLE: M/W ROOF SEALING P.O. BOX 368 wG SM YAIERIALS ARE PROM M TO THE SAFETY HARBOR, FLORIDA 34695 RECPINT EOt SKCFX R1MM NO LAST BE n= OTMOM DRAMLNG NUMBER: AD-FA-0026 PHONE (813) 726-1138 IVT C04WroL 90 SE00 SHIPPED LOOSE HEARTH EXTENSIONS H P.ARTH. INSTA1.I.ATTON- I. REMOVE ANY CARPET AND/OR PAD FROM UNDER THE HEARTH EX89ON AREA 2. INSPECT THE META RAM, G IN THE HEARTH AREA TO INSURE THAT IT HAS BEDI INSTALLED (THIS FLASHING MUST BE PLACED ON THE FLOOR TO PROTECT THE AREA BETWEEN THE FIREPLACE AND THE HEARTH). 1 LOCATE PE HEARTH EXTENSION (SHIPPED LOOSE N THE NNE) AND INSTAL FOLLOYANG THESE STEPS A. CAREFULLY PLACE THE HEARTH EXTENSION N THE PROPER LOCATION IN FRONT OF THE FIREPLACE ASSEMBLY. B. SECURE THE HEARTH EXTENSION TO THE FLOOR W/ 4 +8 Y 2' WOOD SCREWY C. FILL THE AREA BETNEEA THE FACE OF THE FIREPLACE AND THE HEARTH EXTENSION WIN A NON-COMBUSTABLE CAWING OR MORTAR. D. OR FOLLOW THE HEARTH MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. TILE SURROUND . TYP. HEARTH (MAY BE SHIPPED LOOSE) 1. A TYPICAL TILE FRONT FIREPLACE IS SHOWN, HOWEVER THIS DETAIL APPLIES TO ALL FACTORY INSTALLED FIREPLACES. (STONE, WOOD, GYPSUM, ILE, STUCCO, ETC... MAY BE USED IN LIEU OF THE TYPE OF FIREPLACE SURROUND SHOWN ABOVE.) TYPICAL WALL WOOD TRIM FACTORY INSTALLED FLASHING APPROVED BY .JW28rZ N114LNG RDf�Il4wNACiV1®N][ a�au,c�aaawrnsruarq NOnC1: DRAW BY.. DATE REV. LETTER: JACOBSEN HOMES C.L.Y. 6-16-95 . mESE saEarni►noHs AHo orurnncs ARE 0MONAL. PKM7ARY. AND CMMEHM DRAWNG TITIF SHIP —LOOSE HEARTH " P.O. BOX 368 � yA o � �xn TO TC Ljjwzu PHONER(011R3) FLORIDA 26 1138 95 � cwmuk No C RlMu M ODOM DRAMIWG NUMBER AD—FP-0001 10 SMOKE ALARM ADDENDUM Enclosed in the home owner's packet is the smoke alarm user's manual, (if it is not there, contact Jacobsen Homes and one will be sent to you. NOTICE TO DEALER AND SET-UP PERSONNEL This home is equipped with a smoke alarm system and must be tested in accordance with the smoke alarm user's manual after the home is completely set-up and all the electrical connections are done. NOTICE TO CUSTOMER Smoke Alarms have been installed in your Jacobsen Homes. You should be familiar with the locations and operation, and learn how the alarms can be silenced once they have sounded and be familiar with its use. This is a very important safety device installed for your protection. Be sure that it is kept in A-1 working condition by testing if frequently in accordance with the manufacturer's instructions. The alarms operate on household current, and have battery backups. Its purpose is to provide early warning in case of a fire. Again we stress the importance of keeping your smoke alarms in proper working order. TESTING SMOKE ALARM Test smoke alarms after home has been set-up completely. To test the smoke alarm, press and hold the test button on the cover of the unit, until the alarm sounds. All smoke alarms should sound alarms. If all units do not alarm, replace units immediately.. This test should be given to all smoke alarms individually. APPROVED BY REV. 0000or ON 14 OR Z 5 20 INC. FEDERAL MANUFACTURED HDN1E CONSTRUCTION AND SAFELY STANDANUS SET-UP MANUAL ADDENDUM AD-FS-0001-A u TRUSS SHEATHING APPROVED EY IN INC. f®ERAL MANUFACTURED HOME W i�5f RUCAON ADD SIVFETY STMDAiiOS DEALER (SET-UP)INSTALLED PLYWOOD FOR SHEATHED TRUSSES HINGED TRUSS - NOTE: HOLES TO BE CUT IN SHEATHING TO ALLOW OUTLOOKERS TO PASS THROUGH. TYP. OUTLOOKERS FACTORY INSTALLED PLYWOOD FOR SHEATHED TRUSSES L SIDEWALL — ,a WR ;Kowl 3/8' MIN. APA OR TECO RATED SHEATHING APPLIED TO ROOF TRUSSES LOCATED DIRECTLY ABOVE SNEARWALLS (APPLICABLE TO ALL SHEARWALLS) MARRIAGE WALL PENETRATIONS OF THE SHEATHING ON THE TRUSS(ES) FOR NE OVERHANG OUTLOOKERS (PURUNS), ATTIC VENTALA110N. 3/8- SHEATHING TO BE INSTALLED ON -SITE OPENINGS IN TRUSS SHEATHING MAY BE LOCATED AT ANY LOCATION ALONG THE LENGTH OF THE. TRUSS. VANDZONE III (18' X 14 I/2' MAXIMUM SINGLE OPENING SIZE IN TRUSS SHEATHING) (110 MPH)ALL EXPOSURES NOTES: ENGINEER APPROVAL: DAPIA APPROVAL- 1. 3/6' MIN. RATED SHEATHING FASTENED TO ROOF TRUSS WITH 7/16' X PANEL EDGES AND r D.C. APPROVED EY All ALL FRAMING IMIIENMMS`(NO'GLUE`•REGUI� 000or ON MAT a eox 14 INC. K2 fEm& MANUFACTURED HOME CONSTRUCTION AND SAFEN STANDM i JACOBSEN HOMES NOTICE: nmSE SPEaFKAIMS DRAWN BY: R.R. DATE 4-27-98 REV. LETIER: m BOX 368 AND DRAWINGS ARE ORIGINAL. PROPRIETARY, AND CuvKxmRAL MATERIALS OF JACOBSEN MANI1FACn1RINCTRUSS W_ SHEATHING DRAWING TITLE:P.O. SAFETY HAR80A, FLORIDA 34695 PHONE (813) 726-1138 SWA MATERIALS ARC PROVIDED TO 1HCREcmNr FaR SPCCOX FLFPM AM MUST BE KEPI DRAWING NUMBER: CDNnMllAL AND SECAn MOM DTWM. AD—HR-0001 HINGED ROOF DETAIL COMM OF PAIR M W ROOF FROM Sti m Pa911Qi To SET-W Pam IS A mx. n 1%r. 1FT mf1D ROOF WE M SM6'*w1mT ■11 l�p1A1N'JIL KNO MD VX TRAM 12 W APART. LDGi UnM POIi15 WM Jr OF QD OF ROOF SECROM, A161 AUOD IFTNG MW 2FEET aFAW=NXRNRAIL HINGED ROOF IN SHIPPING POS11ION HINGED ROOF IN SET—UP POSITION NDS01 NOTES: 1. BRACE NO ROOF SEC= N THE RAISED P09M W" SWIM HM wo P06o Km Pond ma = POST l0 ROM WAIF 6 SPF j7 FD®w P05i lw m •CIOzrMOODwwOR3-PYr am REF. CALL. PG. C-RF- 223.0 - 223.6 John C. Daedon, P.-L. ► 2 Eng wwrinq, Inc APPROVED BY �� 1 Revised Jnun' 06,2006 (I VC. FFDFRAI YAWIFArf ffD HOW CONSTRUMON AND SAFETY STANDAM HRnw U.. - -- -- JACOBSEN HOMES um aa>a ?m �•A• 06=o2—O6 m was II"FACDfn! n ORAINNG lI1lE HINGED ROOF DETAIL P.O. BOX wo NG SU01 WiCiAli AIE f7QM 101E EIWLISAFETY HARBOR. FLORIDA 34895 Rl1EQ 10 4BofIC 1IR03S AIO Yaf K. ORAwfIC N um PHONE (813) 726—u3e I wT wfm K ma Sa Fr aR AD—HR-0002 13 HINGED ROOF DETAIL WER AYMENT TO BE GLUED 3' MIN. ON BOTH SECTIONS OF HINGE ROOF. FOR WIND ZONES 2 AND 3. RAISE EXTENDED SHINGLE AND UNDERIAYMENT AND AND A YIN. 4 1/2' WIDTH OF ROOFING CEIENT TO TOP OF LAST SHINGLE ROW ON FIXED ROOF SECTION. (THIS IS TO BE DONE BEFORE RAISNC HWIGED ROOF SECTION.) SHINGLE AND UNDERLAYMENT CEMENTING AT HINGED AREA ATTACH 2 X 6 X 8' BLOCK BEHIND 2 X 6 OVERHANG FASCIA BOARDS AND SECURE WITH 3-18 X 3' WOOD SCREWS EACH SIDE OF GAP. APPROVED BY Revised . NP1Nov 30,2006 • INC. FEDERAL MMUFAMRED NONE \ Ow- CDNMUCFION AND SAFETY STANDARDS BLOCK ATTACHMENT AT FRONT AND REAR OVERHANGS VANDIONE 11 (110 MPH) All EXPOSURES NOTESs ENGNEFR APPROVAL: DAPIA APPROVAL: 1. LiRACE RAISED ROOF SEM IN WE RAISFD M10 NCR SNWQNG HINGED KING POSTS INTO P05111GIL 1mS 0� . John . Does P K2 Eng+nMk* m NOTICE. oRAfAI By, DATE REV, 1Fi1i JACOBSEN HOMES 1asE -weamwe AND DRAW= ARE D.T. 10-02-06 /R� �'D ao:loo+nA< DRAWN- TIRE:. P.4 Box 366 � � � � HINGED ROOF DETAIL SAFELY HARBOR. FLDRbA 34693 KWM l01 ftW AW= AND,1= DRAWN- WWM PHONE (613) 726-1136 MR a-mm"Alm sow fro mas. AD—HR-0003 1 1d SHINGLE AND UNDERLAYMENT APPLICATION ON HINGED SECTION INSTALL ON SITE 150 FELT WITH A 6' MIN. OVERLAP ONTO MAIN ROOF CEMENTED WITH ROOF TAR AND SECURED PER NOTE #2 ONE-PIECE SHINGLE CONTINUE 151 FELT TO ROOF PEAK ---\ UNpERLAYMENT f MIN. OVERLAP (TYP•) zo CD v 6' MIN. TAR AS SHOWN I I .(APPLIED ON SITE) z 1 SEE NOTE /3, _ I I-� ••• 1 I I 1 I I I n SEE DETAIL 'A' � I 1 I 1 1 SECURE FIRST ROW OF SHINGLE TO BE INSTALLED ON SITE WITH • 6 STAPLES (1' X 3/4' X 16 GA OR ROOFING NAILS) PER SHINGLE MANUFACTURER'S INSTRUCTIONS AND CONTINUE TO PEAK. REMOVE THE ONE PIECE SHINGLE UNDERLAYMENT IN THE GAP (HINGE SECTION IN DOWN POSITION) BEFORE LIFTING THE HINGED SECTION OF THE ROOF TO ITS FINAL POSITION AND BEFORE INSTAWNG THE 151 FELT AND SHINGLES. DETAIL A 1 CEMENTING OF 15 j FELT IS NOT REOUIRED IN ANY AREA EXCEPT W IX NOTED. r FASTENING OF 15/ FELT IS NOT REQUIRED. (FASTENERS APPLIED JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) >f 3 EXTEND THE FIRST LAVER OF ON SITE 15/ FELT ONTO THE FIXED ROOF A MIT. OF 6' AND UNDER THE LAST COURSE OF FACTORY INSTALLED SHINGLES IF NEEDED TO MAINTAIN THE 6' MIN. OVERLAP ONTO THE FUND ROOF - INCLUDED IN THE HINGED ROOF ADDENDUM ARE DETAILS*AD-HR-0001 (WITH SPECIFIC END PANEL LAYOUT), AD-HR-000Z, AD-HR-0003, AND AD-HR-0004. JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 NOTICL ,Hm ggDw l m MIND DRAII ='Am gowL s DRAW MAMINAIW. SM MAIDW AK FROM M ,O 1i K DRAW 1gww oii AIo SfL1�iET nm Ohm m I WINDZONE III (110 MPH) ALL EXPOSURES -OPROVED BY SFF 2 2 20 IPINC. MANUFACTURED HOME rilON AND SAFETY STANDARDS M.T. 1 "-'- 9-20-03 SHINGLE AND UNDM AYMENT AD-HR-0005 I PEAK INSTALLATION DETAILS SECURE ROOF PEAK ASSEMBLIES TO - HINGED RAFTER WITH #8 X 4' SCREWS, 6.1/2" O.C. MAX DECKING ON RIDGE BLOCK ASSEMBLIES FASTENED WITH (6) 7/16" X 1 1/2" X 16 GA. STAPLES INTO EACH 15' O.C. RAFTER AND 3 1 /2" O.C. MAX. INTO 2 X 4 RAIL (TYPICAL BOTH SIDES) -lV NDSOI NOTES; I. SEE AD-HR-0007 FOR INSTALLAIION OF UNDERLAYMENT AND SWNGLES. SEE AD-HR-0002 FOR ASSEMBLY DETAILS. ALL VANDZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L CRC - 167.01 - 167.02 PEER APPROVAL DNA APPROVAL - APPROVEO BY Revised 04 un 09,2006 John 0. liOtad E, P.C. FEDENAI M�MIFACiU IDN INC. CONSTRUCTION •NO LFET1' SfAlID1RD5 Enginwring, Inc OU FIRO JACOBSEN HOMES NnaonesAro �AT•^•� TNEsc aures MCelc O.A. 06-06-06 OieONsau M. PRDPR;TARY. AM rd1F700111AL ORAWN6 AIIE: YATOEALS Or JICtD= WNl�AL1URNC . P.O. Box 368 Esc 9" YAnRU ARE FWt= 10 DE PEAK INSTALLATION DETAILS SArETY PHONE (727) 7266--1-113B 695 m� r� TTAM S100 FUN Of i DRA1iWc NU16ER AD-HR-0006 16 SHINGLE/UNDERLAYMENT INSTALLATION TOP COURSE(S) OF SHINGLES TO SITE INSTALLED SHINGLES (USING THE OVERLAP PEAK AS SHOWN_. 6 FASTENER METHOD) AND CAP INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS. SHINGLE INSTALLATION INSTALL FIRST LAMER OF 151 FELT TO ROOF WITH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/OR EXISTING FELT AS SHOWN. SEE OTHER DETAILS FOR SITE INSTALLED ROOF PEAK UNDERLAYMENT INSTALLATION I NOTES: INSTALL TOP LAYER OF 151 FELT TO ROOF NTH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/OR EXISTING FELT AS SHOWN. IBY . AUG 0 I INC. NOTICE: DRArRI BY: DATE: REv. LETTER: JACOBSEN HOMES Twg SP+:011INS NO DRARNa ARE M.T. 7-28-04 O MAL Pfltpl TAR►. A1D WiYdEENAAL DRAWK TITLE: _ ,. VAIERALS OP JACOBSirI mmwhCNg1RG SHPIGLE/UN DERLAYMENT INSTALLATIONP.O. BOX 368 NG 101 IUTEIRALS ARE PROYM TO iK SAFETY HARBOR, FLORIDA 34695 REOMI FOR SEM PIAFW NO RUST K DRANRIG MNLBER HIPHONE (727) 726-I138 IvT CdfWVK AIO MET RIOT oTRDIS. AD-HR-OW7 1 ADDENDUM TYP. SHIP -LOOSE PLUMBING SUPPORT �- FASTEN TO FLOOR FRAMING NEM EIER W/ STAPLE OR NAL BANDING STRAP ". PED' AROUND PIPE AND FASTENED TO FLOOR FRAMING ADE OF NOT LESS THAN 1/4' PER FOOT MUST BE MAINTAINED TOWARD THE I OUTLET. WHERE VS CRADE CAN NOT BE ACHIEVED, NOT LESS THAN 1/8- OOT MAY BE USED WHEN A FULL SIZE CLEANOUT IS INSTALLED AT THE UPPER END. ..,J VIEW OF DRAIN PIPING 1. PIPE CLEANER AND GLUE SHALL ALSO BE SUPPLIED BY THE MANUFACTURER FOR PLUMBING CONNECTIONS. 2. 48" O.C. MAX. SUPPORT SPACING. JACOBSEN HOMES DcsESKCM SSf�"aMAO=Am. DrUtwer. R.R. DACE 7-17-97 revLErILx: MrAAL PRMIA". Alm 00faEUU'l MAIM PILE SM MAXIMS d A DMIYWY'ACVA*4 P.D. R, xa W- sm Y„ l ffixg A,a „,� r, it PLUM,.O ING SUPPORT SAFETY HARBOR, FLORIDA 3�695 K~ FM SWX ntaM AV W= K DRAPING NUY30b PHONE (eu) 726-1`138 an cmnODM Mo soar lm CUM AO—PL-0001 18 OPEN PORCH RAILING(SI IT IS THE RESPONSIBILITY OF THE SET-UP CONTRACTOR OR GENERAL CONTRACTOR ON SITE TO INSURE THAT THE RAILING(S) INSTALLED OR TO BE INSTALLED MEET ALL CODES IN EFFECT AT TIME OF HOME INSTALLATION. NOTES: PPROVED BY I� INC. RAL MANUFACTURED HOME ST RUCiIOW AND SAFETY STANMU JACOBSEN HOMES "0T1C n+ESE svEcncATR>Ns AND cs u� DRAW M.T.3-30-05 a>E REV.1ETTER ORGINAL. PROPREURY, AND CONFIOENRAL DRAVMG IRL mq P.O. BOX 368 MATERIALS (IF JACOBSEN MANUFACTUM NC SUCH MATEAwS ARE FRONDEO TO INE OPEN PORCH RAILING S SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 REOPM FOR STM RMOSFS AND NMI BE IVT CWOENIK AND SEW FROM O*M ORAI9MG NUMBER: AD—PO-0001 19 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST rt< ROOF), SOLAR TUBES AND PLUMBING 41 VENTS SEE AD—PR-7007 do 7009. MAX. ROOF SLOPE FOR ROOF DECKING DETAILS SEE AD—PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE FOR ROOFING DETAILS SEE AD—PR-7002 j` SEE AD—PR-7008 SHIP THIS SEC. LOOSE 't (SITE INSTALLED) � — — —— — — — — — C FOR OVERHANGS SEE AD—PR-7OD3. FACTORY INSTALLED RAFTERS (CENTER SECTION) REMOVE ALL FACTORY INSTALLED \— FOR ROOF VENTING BOTH FACTORY --IPOLYVINYL BEFORE INSTALLING THE AND ON SITE SEE AD—PR-7005 & 7006 ON SITE PITCHED ROOF RAFTERS CENTER SECTION OF TRIPLE WIDE TYPI jL TRIPLE WIDE HOME REF. PG. IW-07-0011 WITI- -ATE INSTALLED PITCHED FOR FASTENING C ATER SECTION RAFTERS NOTES: DAPIA APPROVAL' APPROVED BY Revised Oct 25,2007 INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS NOTICE DRAWN BY: DATE REV. LETTER: JACOBSEN HOMES ,HIM ��I,TIM „M DRAWNM AMO.A. 10-24-07 min ORI64UL, PROPRIETARY, AND CONFIDENR& MATERIALS OF JACOBSEN YANUFACTURM oRAW1NG nRE: ON SITE PITCHED ROOF DETAILS P.O. BOX 368 INQ SM MATMALS ARE PRDMDEED TO THE SAFETY HARBOR, FLORIDA M95 REfpENT FOR SPM RNMES AM MIST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CWWENTIAL AND SECRET FR01I OTHM AD-PR-7001 20 ROOF- TO ROOF ATTACHMENT SECURE SITE INSTALLED ROOF DECKING r SITE INSTALLED 7/16' MIN. ROOF WITH 7/16' X 1 1/2' X 16 GA. STAPLES DECKING SECURED WTH 7/16' X 1 1/Y (12) EACH SIDE OF MARRIAGE LINE TO X 16 Ga STAPLES, 2' O.C. MAX. TO EACH 16' O.C. RAFTER. EACH 15' CLC. RAFTER. SEE DETAIL 'A' SEE NOTE 11 11' MIN. SITE INSTALLED DECKING OVERLAP FACTORY INSTALLED ROOF DECKING SITE INSTALLED RAFTER TO ALIGN WITH [J. RAFTER BELOW. FACTORY INSTA :ED a/ SEE NOTE /2 EBE E RIDGE 14�S lk I 18' MIN. NOTEDECKING WA CROSS-SECTION FACTORY INSTALLED RAFTER (CENTER SECTION) w1NDzoNe•� ALL EXPOSURES (110 MPH) REF. PG. RC-07-0044 20 PSF ROOF 10 PSF D.L. NDS01 REF. CALCL C-FS3 - 88.01 NOTES, ENCI*XR AWWWAU DAM AMOYAU I. SECURE EACH 16' O.C. RAFTER TO RAIL BELOW WMTH 2-/10 X 4 1/2' SCREWS AT EACH RAFTER END. SITE APPROVED BY INSTALLED PITCHED RAFTER TO ALIGN WTH FACTORY INSTALLED RAFTER. (EA. SCREW TO HAVE 1 1/4' PENETRATION WIN.) Z ATTACH A LIE RAFTER RAILS (OR RIDGE BEAMS) WITH Jun 09,2006 N 14 j10 X 4 1 2 SCREWS 9 QC MAX. SPACING. ,fs Q,� C. I SEE AD-FA-0020 FOR GAP TREATMENT BETYIEEN SECTIONS. John C. 8 enm' PP.k. An" omwaclu I-NN K2 Engirmering, Inc. ma CO"smucnm•MD s"mr sT"o"oS JACOBSEN HOMES NO=& s � CRAW 81. o.a DA7E: 06-02-06 Idv 1ET1Eit P.O. Bolt 366 SAFETY HARBOR. FLORIDA 31695 wcmnmr wlomus av A=M KANWACn�s�e W6 R,„ UIDI„u AK P� 10 If A H DRA DTIf ROOF TO ROOF ATTACHMENT DRAW$ M I IA 'AD—PR-7002 PHONE (727) 726-1138 na m Re YU= PLIP00 110 VW K tm ew wrc Me KMI wa pm 21 RAFTER TOP END ZONE RAFTER/OVERHANG ASSEMBLY ALT. CONSTR. RAFTERS 2 X 6 OUTLOOKER 19, O.C. MAX. BETWEEN OUTLOOKERS ~+ aC "... 2 X 6 OVERHANG FASCIA THIS TRUSS NST&LED ON SITE BOTTOM CHORD 160- DOUBLED END ZONE RAFTERS TYP. 160 O.C. l9.0 Al,(,� 0 y18• D 2 X 4 NAILING BLOCK (INSTALLED ON SITE) MIN. (3) .131' X 3' NAILS FROM NAILING BLOCK INTO RIM PLATE OF ADJACENT SECTION OF UNIT, AND . MIN. (3) .131' X 3' NAILS FASTENING FASCIA INTO END OF NAILING BLOCK 2 X 6 OUTLOOKER 19' O.C. MAX. BETWEEN OUTLOOKERS ALL OUTLOOKERS SHOWN ARE 2 x 6 SPF /3 FLAT SEE CHART FOR FASTENING OUTLOOKER TO TOP CHORD -MULTIPLE TRUSSES FASTENED TOGETHER W/MIN..131- X 3' NAILS OR MIN. 7/16' X 2 1/2 X 15 GA. STAPLES 16' O.C. MAAMUM INTO TOP k BOTTOM CHORDS ONLY. '*" 2 X 6 OVERHANG FASCIA 2 X 6 FASCIA FASTENED TO OUILOOKER � END ZONE ASSEMBLY NOTE: W/Ii9N. (5) 7/16' X 2 1/2' X 15 GA. STAPLES OR MIN. (3) .131' X- 3' NAILS (SHIPPED ASSEMBLED FOR SITE INSTALLATION) DMU (TYPICAL AT ALL CENTER BRACES) IN THE ENDZONE PER FASIEIER CHART. SINGLE TRUSS ONLY REQ'D OUTSIDE OF 3 FL AM SS MAY BE PLACED ON EIM SIDE NDS01 NOTES: 1. ALL TRUSSES LOCATED WITHIN 36' OF THE END OF THE SECTION TO BE DOUBLED. 2. SEE OTHER DETAILS FOR TYPICAL ROOF FRAMING. 3. EACH TRUSS IN END ZONE AREAS ARE REQUIRED TO BE FASTENED PER AD-PR-7002. TYP. OUTLOOKER FASTENING. FASTENERS: QUAM.. PENEIBMIM J31 PD NNL 5 1 1/Z� 15 GA. • STAPLE 8 1' fe SCREM 2 1- (INCL TR') OU1 OCUR FASTEMRS MAY BE IMAM VNNMONE 111 FROM TOP OW DOWN F KIMIN ALL EXPOSURES 6 yANTAIM, (110 MPH) 20 PSF ROOF 10 PSF D.L. REF. L& ' C-RC-197.01-197.02 DIG M R APPROVAL DARA APPROVAL APPROVED BY 00o Feb 05,2008 z'f(�14 rNC. FEDEME John C. Doe�n, P•�• CONS LIIAONANDURED STANDARDS O)NSTRUGTION AND SAFETY STANDARDS K2 EngineGTlrlg; Inc. JACOBSEN HOMES NOTIC@ TNESE s4EaIts uw m O mos ARE DRAWW BY: O.A. DALE 1-29-08• M. LETIM ORMAL, PROPR6MRY. AID WFW ML UAIERM OF DAM )FACRM DRAWW VM' A P.O. BOX 36B W- 80 MATOWS ARE PWWW TO TEE END ZONE RAFTER/OVERHANG ASSEMBLY SAFETY 138 695 SUC DRAWDG NUABERPH�726-1 � mMMOW�am AD-PR-7003 22 ON SITE PITCHED ROOF DECKING INSTALLATION TYP. ROOF FRAMING 16" ON CENTER MN. — I TRIPLE WIDE CENTER SECTION PEAK SITE INSTALLED DECKING ON PITCHED NO BLOCKING REQUIRED TRUSS SECTION & REMAINDER OF AT BLOC CONTINUOUS PANEL BOTH OUTSIDE SECIONS (2 FULL ROWS OF SHEATING) SEAMS BETWEEN TRUSSES SEE OTHER DETAILS TO SECURE TRIPLE WIDE MARRIAGE LINE SITE INSTALLED PITCHED TRUSSES MIN. WIDTH PER SHEATHING REQUIREMENT I LMANUF. INSTALLED DECKING TO HERE APA RATED ROOF DECKING (OR EQUAL) I 1b VAND20NE 01 ALL EXPOSURES (110 MPH) 20 PSf ROOF 10 PSF D.L NOTES: r,.�L,. 1. 1/B' MAXIMUM GAP AND 1/16" MINIMUM GAP BETWEEN DECKING �:—A PERPENDICULAR AND PARALLEL TO TRUSSES, APPROVED BY 2. ROOF DECKING MATERIAL TO BE 7/16" APA RATED ROOF (24/0 Waz�:� Revised. SPAN RATED) DECKING (EQUAL OR BETTER). John G. Do d-: r ' Oct 29,2007 3. OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THE SAME DECKING PATTERN. K2�flC� «yTl� 1; . tl;c.N r NC. FEDERALEiAEIUFACfURED HOME 4. FASTEN DECKING TO ROOF FRAMING WITH 7/16 X 1 1 /2" X 15 CONSTRUCnON AND SAFETY STANIMIDS GA. STAPLES AT 3" O/C EDGES AND FIELD DRAW BY- DATE RtV. LETTER: JACOBSEN HOMES 11ET� SPEfi1CAAQ NO DRAUM Alf O.A. To-24-0� aWONAL MW ElE1AW NO OQi1DO IX MARL lRE n P.O. BOX 388 MATFNO W ,UECGBM MMWAClIUM wt Sm MV1axa AEEE: EIRVYIDED 101NE ON SITE PITCHED ROOF DECKING INST. sAFEPH(�HARBOR. T FLORIDA23 ss 9 o0I � WEB oRArwc M> AD—PR-7004 23 SITE INSTALLED PITCHED ROOF VENTING TYP. 50 SQ. IN. ROOF VENTS (SEE AD-PR-7006 FOR QUANTITIES) TYP. 100 SO. IN. CUTOUTS FOR - VENTILATION OF ROOF SECTION (SEE AD-PR-7006 FOR QUANTITIES) FLAT CENTER SECTION OF ROOF INSTALLED AT MANUFACTURER TYP. ROOF INSULATION CEILING PANEL CENTER SECTION (FLAT TRUSS) MARRIAGE WALLS MARRIAGE WALLS FLAT CENTER SECTION NOTES: SITE INSTALLED CENTER SECTION OF ROOF DAPIA APPROVAL: APPROVED BY 41 � Revised Oct 25,2007 INC. :RAL MANUFACTURED HOME STRUCTION AND SAFETY STANDARDS NOTICE DRAWN BY. O.A.O.A• 10-24-07 REV. LETTER: JACOBS EN HOMES THEM SPE�,�ATE: AM DRAWINGS ARE FRiOMETARY, AND CONFIDENTIAL AORNMAL. DRAWING TITLE: MATERIALS °F JACOBSEN MANUFACTUM SITE INSTALLED PITCHED ROOF VENTS ❑" P.O. BOX 368 W- SUCH YATERWS AM PROW= TO THE BE SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 REUENT FOR SFEOAC PURPOSES AND HST KEPT COKMENUAL AND SECRET FROM DIM DRAWING NUMBER AD-PR-70O5 24 ROOF VENTING ir. 100 S0. vL CUTOUTS FOR VENTI AM OF ROOF SECTION i ■' (SEE CNARi FOR RE.am its) r_ 100 SO. IN CUTOUT VENT HOLES R N EQUIRED 1N FLAT ROOF SECTIO (16n X SECTION Lma CUTOUT NOTES 0 TD IS -r I 15-C 10 31'-.r 2 31'-3' TO 46 -IW 3 16 -1 10 6 -6 4 6Y-6 TO -0 5 I I . MARRIAGE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED I "I I MARRIAGE WALLS c I LOW VENT LOW VENT a -a I •50 SO IN. VEN75 REQUIRED I `3 FRGH PENT IN SI E INS ?Allyn SRUSS SECTION = r_ .. - I CENTER LINE OF CENTER SECTION (Nn z SECUX U=T1! N01 IMIL' WE %M A b-! 1101E rot 31- 101�- T UK 4w-w 10 Gr-r I I I EA SK IS a,--3 21A SK fit i aN701=1D00OW6*US a-r 1 • LOW WENT_ TTP. 50 50. iK ROOF VENTS LOW VENT (SEE CHART FOR REOUREMENTS) V( l MARRIAGE WALLS Ir I SITE INSTALLED CENTER SECTION OF ROOF. I A DAPIA INC.20 IP MANUFACTUREO HOME iCHON AND SAFETY STANDARDS DRAIN BY. - DAM REv LETTER: III JACOBSEN HOMES mm s'EC111CJ►�AO AM DRA.RsN[ R.R. 01-22-04 T� uiL oRATr+c E RW VENTING I, P.O. BOX 368 We WM MAUS S N[ FRDW= 10 TQ SAFETY HARBOR FLORIDA 34695 KWW ►oR SPW ftWM NO KV K DRAWING MAI ER PHONE (727) 726-1138 1wT COIn0 ak NO S»i nm Otoa AD-PR-7DD6 i PITCHED ROOF EXTENDED VENTS SITE INSTALLED VENT CAP OR SOLAR TUBE VENT CAf (OR SOLAR SITE INSTALLED FLEX DUCT SITE INSTALLED VENT (SEE DETAIL 'A') \ /SITSECTIONLLED OF ROOF ER / �— EXTEND FLEX DUCT 3' ABOVE RAFTER SHEATHING FLEX DUCT (FACTORY INSTALLED) FACTORY INSTALLED SHEATHING — FACTORY INSTALLED CENTER EXTEND PIPE 3' ABOVE SHEATHING SECTION OF ROOF PLUMBING VENT (FACTORY INSTALLED) LTYP. CONNECTION TO VENT FAN, SOLAR TUBE, OR EXTEND TO RANGE HOOD MARRIAGE WALLS CEILING PANEL SITE INSTALLED PLUMBING VENT PIPE /(Ex TEND 3- ABOVE ROOF) (SEE DETAIL 'B') MARRIAGE WALLS FACTORY INSTALLED FLAT CENTER SECTION :XHAUST DUCT SPLIT 1ND FASTENED TO ROOF 1ECKING OR BACKER VITH MIN. 4— 8D NAILS N LIEU OF FASTENING IUCT TO VENT CAP. SITE INSTALLED FLEX DUCT ti SHEET METAL SCREW @"`I�'—FLEX DUCT (FACTORY INSTALLED) NOTE: EXHAUST DUCT (FLEX DUCT OR RIGID) SECURED WITH 1 SHEET METAL SCREW MINIMUM AND ALUMINUM TAPE TO SEAL AROUND DUCT AFTER SCREW IS IN PLACE. DETAIL 'A' NOTES: 1. FOR VENTS NOT SHOWN INSTALL PER MANUFACTURERS SPECIFICATIONS. Z SEE OTHER DETAILS FOR ROOF FLASHING INSTALLATION. 3. EXHAUST DUCT MAY BE RUN THROUGH EITHER A SOUARE OR ROUND HOLE CUT N ROOF DECKING. - 4. RANGE AND BATH/AIR DUALITY FLEX DUCTS TO BE SPUCED WITH ALUMINUM TAPE AS SHOWN N THE DETAIL ABOVE. 5. SECURE SITE INSTALLED PLUMBING VENT PIPE INTO COUPLER WITH APPROVED GLUE. PLUMBING VENT ROOF FLASHING (SITE INSTALLED) VENT PIPE (SITE INSTALLED) µSICOUPLER TE INSTALLED) InYVENT PIPE (FACTORY INSTALLED) DETAIL ' B' DAM APPROVAL: APPPOVED BY JUN I INC. FEDERAL ANUFACTURED HOME rnNSTRU TIDN AND SAFETY STANDARDS NOTICE DRAWN BY: R.R. DA>E O1-23-04 REV. LETTER: J AC O B S EN HOMES TMM SFEFr,uuals AM CRAWNZ AK Olaou- PMVKTWI, AM CO1itOD UX DRAWING TIU- _ N P.O. BOX 368 W- RICH AT oir " r+AIWSACTO INE PITCHED ROOF EXTENDED VENTS .tc. sual rnuTeAts Nt[ Pti0Y0EO ro t1E SAFETY HARBOR. FLORIDA 34695 RECPIERT FOR STfOF1C PUWOSLS NO 051 K DRAWING NUMBER: ` PHONE (727) 726-1138 KEPT CO1IrID%q ". SECRET 1ROr OTHM AD—PR-7007 12a SITE INSTALLED SHINGLE AND UNDERLAYMENT HELD INSTALLED 15f FELT MIN. INSTALLED OVER THE FACTORY INSTALLED UNDERLAYMENT 91H A 6' MIN. OVERLAP AND A MIN. 6' WDTH OF ROOF CEMENT.. 151 FELT TO HAVE A 6' YIN. OVERLAP 15f FELT ALSO CEMENTED WTH A 6' WIDTH AROUND AND A MIN. 6' WiDTH OF ROOF CEMENT ALL PENETRATIONS OF THE UNDERLAYMENT AND : THIS ALSO APPLIES TO ENDLAP SEAMS. PERIMETER OF ROOF. I c • ` FIELD INSTALLED ROW SHEATHING b� .� r -1 r 1 r� r, _1 r -1 I �'� 6' WDTH OF ROOF CEMENT WHEN t 1 t L OPTIONAL 15f FELT IS INSTALLED. r- 1 r -1 •'•' - r OPRONAL LAYER OF 151 FELT r `1 J� � I ONE-PIECE SHNM INOERIAYYFNT ROOF SKEK NG (TYP.) THIS Row OF SHINGLES TO BE FIELD INSTALLED AFTER THE UNDERLAYMENT HAS BEEN INSTALLED. THE LAST COURSE OF FACTORY INSTALLED SHINGLES TO LEAVE A MINIMUM OF 6' FROM THE TOP OF THE SHINGLE TO THE EDGE OF THE FACTORY INSTALLED DECICING FOR UNDERLAYMENT OVER LAP OF 6' MINIMUM. FASTENING DWTAIL NOTED'- 1. CEMENTING OF OPTIONAL 150 FELT IS NOT REWIRED IN ANY AREA EXCEPT WHERE NOTED. 2. FASTENING OF OPTIONAL 15 f FELT IS NOT REQUIRED. (FASTENERS APPLIED ARE JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) jOhrI (I�,�j�=+�Sn' 3. SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS KP_ F_ng;l Lc-;: 09, InG` ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED. YNNOZONE O (110 MPH). ALL EXPOSURES OVED BY Revised Oct 29,2007 rpNC. MANIFACTHRED HOME C ION AND SAFETY STANDARDS O.A. NONEMs,: JACOBSEN HOMES oNs A..w� TNEg sP�raTlND dLA.Ncs lO..to-24-07 FlAWA OAttilX. PROPii fMX AN COFIOBLIYIL WAV" W&- A P.O. BOX _W NC am Y OF p om m SITE INSTALLED SHDIGI E AND IIFDkALAYL HT cm SAFETY OOR.FLORIDA �s5 �r at�lc Nlweo PHONE �an AD-PR-7008 TYPICAL FLASHING INSTALLATION ROOFING TAR UNDER NAILING FLANGE AT ALL FASTENERS TYPICAL SHINGLE ROOF oe b/ ROOFING TAR APPLIED OVER TYPICAL FIELD INSTALLED RAFTER FASTENERS AND UNDER ALL SHINGLES OVERLAPPING THE ROOF FLASHING. .105" X 1' MINIMUM ROOFING NAILS OR .1137 X 1' MINIMUM NAILS MAY OPTIONAL SHINGLES MAY BE APPLIED TO BE USED IN LIEU OF STAPLES FOR FASTENING FLASHING TO ROOF. COVER ANY ROOF VENT FLANGE BY SECURING THE SHINGLE TO THE FLANGE AREA MATH ROOF- ING MASTIC (TAR). OPT. SOLAR TUBE INSTALLATION TYPICAL SHINGLE ROOF SOLAR TUBE DOME, MATH NAILER FLANGE, SECURED TO ROOF, ON TOP OF UNDERLAYMENT, AND TOP OF FLANGE UNDER SHINGLES. WITH BOTTOM OF FLANGE.OVER SHINGLES (BOTTOM FLANGE MAY BE COVER WITH SHINGLE TABS SECURED MOTH AN APPROVED CAULK). TUBE SUPPLIED BY SOLAR TUBE MAN. NOTES DAPIA APPROVAL: 1. ROOF FLANGE FASTENED TO SHINGLE ROOF WITH MIN. 1- X 1- X 16 GA. APPROVED BY STAPLES 6" O.C. (SHINGLES APPLIED UNDER LOWER END OF FLANGE). INC. FEDEIIAL MANUFACTURED HOME CON RUC110N AND SAFETY STANDARDS JACOBSEN HOMES NOTTCB: TKS<SKCIFICA1IMISAMM>RAIMAK DRANK BY: M.T. DATE: 02-04-04 REV. LETTER DMANNC TITLE: G GNAL PROPREIART, AID COWM1tA1 Aa, P.O. BOX 368 NABS a jm=sD# uAWACT11mS IK- 901 MAXRIAIS All PROVOM TO 11E TYP. FLASHING INSTALLATION DRAWING NUMBER - AD—PR-7009 SAFETY HARBOR. FLORIDA 34695 PHONE (013) 726-1138 REaMl rot SPL1f1C NIRPM13 MD IUST K ITT arsmt>tW NO SLCK1 n0I O>NIX 28 ADDENDUM GENERAL NOTES / TIE-DOS"NS NOTES: I. FRAME TIE -DOWNS SHALL BE INSTALLED TO PROPERLY SECURE THE HOME. 2. VERTICAL TIE -DOWNS ARE REQUIRED IN ADDITION TO THE FRAME TIE -DOWNS. 3. VERTICAL TIES MAY BE SECURED TO THE SAME GROUND ANCHOR AS THE FRAME TIE-CCYNl S WHEN A DOUBLE HEADED ANCHOR IS USED AND IS CAPABLE OF RESISTING THE COMBINED LOADING: VID4 ANCHORS ARE NOT INSTALLED AT THE ANGLES) SPECIFIED IN THE TABLE(S), A STABILIZER PLATE MUST BE :NSTALLED IN ACCORDANCE WITH THE ANCHOR MANUFACTURER'S INSTRUCTIONS. 4. FRAME TIE -DOWNS AND ANCHORS ARE NOT SUPPLIED BY JACOBSEN HOMES (TO BE SUPPLIED BY OTHERS). 5. VERTICAL TIE STRAPS MAY BE SUPPLIED BY JACOBSEN HOMES OR ANCHOR BRACKET MAY BE INSTALLED BY JACOBSEN HOMES FOR ATTACHMENT OF VERTICAL ME STRAPS, IN EITHER CASE ALL ANCHORS AND END TREATMENTS ARE TO BE SUPPLIED BY OTHERS. 6. ALL GROUND ANCHORS AND FRAME TIES SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. GROUND ANCHORS AND FRAME TIES ARE NOT TO EXTEND BEYOND THE EXTERIOR WALL OF THE UNIT. 7. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER SHALL BE PROTECTED WITH A MIN. OF 0.30 07. OF ZINC COATING PER SQUARE FOOT OF STEEL a DESIGN BASED ON 95 1/2' I -BEAM SPACING AND A MAXIMUM SIDEWALL HEIGHT OF 8'-0' (82' I -BEAM SPACING IS ACCEPTABLE FOR 16 WIDE SECTIONS OF MULTI -WIDE UNITS W/ 90' SIDEWAL.L HEIGHT ONLY). 9. LONGITUDINAL TIES SHALL BE INSTALLED ON THE INSIDE OF EACH.I-BEAM AT THE -CROSS -MEMBER LOCATIONS OR PER ALTERNATE DETAILS IN ACCORDANCE WITH THE SPACING TABLES AND NOTES 4, 6, 7 AND 16. 10. FRAME 11E-DOWNS SHALL BE 'WRAPPED' AROUND THE MAIN [-BEAM (AS SHOWN ON Tf. CROSS-SECTION DETAILS) AND SHALL COME OFF THE TOP FLANGE OF THE I -BEAM WITH AN APPROVED BUCKLE OR LOOP. 11. ANCHORS SHOULD BE CERTIFIED FOR THESE CONDITIONS BY A PROFESSIONAL ENGINEER ARCHITECT OR A NATIONALLY RECOGNIZED TESTING LABORATORY AS TO THOR RESISTANCE BASED ON THE INSTALLED ANGLE OF THE DIAGONAL ME AND/OR VERTICAL LOADING AND ANGLE OF ANCHOR INSTALLATION AND TYPE OF SOIL IN WHMH THE ANCHOR IS TO BE INSTALLED. 12. GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND BE AT LEAST 12' ABOVE THE WATER TABLE 13. GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILIZER PLATES SHOULD BE INSTALLED TO PROVIDE ADDED RESISTANCE TO OVERTURNING OR SLIDING FORCES 14. 'ANCHORING EQUIPMENT SHOULD BE BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WITH TESTING PROCEDURES IN ASTM STANDARD SPECIFICATION D3593-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS. 15. ALL GROUND ANCHORS TO BE RATED FOR LOAD LISTED IN TABLES, TIMES 1.5 SAFETY FACTOR OR AN ULTIMATE LOAD OF 47251 (31501 DESIGN LOAD), WHICHEVER IS GREATER. VALUES IN THE TABLES ARE DESIGN LOAD VALUES. 16. A MAXMUM OF TWO LONGITUDINAL TIE -DOWN STRAPS MAY BE INSTALLED AT A SINGLE CROSS -MEMBER LOCATION. IF MORE THAN TWO LONGITUDINAL TIE -DOWNS ARE REQUIRED (SEE APPROPRIATE SPACING TABLES) ADDITIONAL CROSS - MEMBERS MUST BE USED FOR ATTACHMENT OF STRAP(S) (OR SEE OTHER DETAILS FOR ALTERNATE STRAP ATTACHMENT). 17. LONGITUDINAL TIE -DOWN STRAP(S) MAY BE INSTALLED AT AN ANGLE NOT PERPENDICULAR TO THE CROSS -MEMBER TO WHICH IT IS ATTACHED (SEE NOTE 16) IF REQUIRED TO MISS PIER LOCATIONS OR OTHER OBSTRUCTION(S). 18. ALL FIGURES (DETAILS) SHOWN IN THIS SECTION ARE TYPICALS ONLY. REFER TO THE APPROPRIATE TABLES FOR THE REOIIRED NUMBER, SPACING AND/OR SPECS OF SPECIFIC RE -DOWNS AND ANCHORS REQUIRED. 19. SEE OTHER DETAILS IN THE SET—UP MANUAL AND ADDENDUM FOR 6LOCKBNG REQUIREMENTS. ALL BLOCOG DETAILS CONTAINED WITHIN THIS MANUAL ARE APPLICABLE FOR ALL ZONES AND ALL EXPOSURES %.cQyi ROVED BY .8A,— THESE NOTES AND DETAILS ARE APPLICABLE ? a` No. O : - T 5 1 FOR WIND ZONE 1I AND/OR WIND ZONE III. THEY - t ENE8703571 i ARE ALSO APPLICABLE TO BOTH EXPOSURE 'C' INC, AND EXPOSURE V. SEE APPROPRIATE TABLES � FOR SPECIFIC INFORMATION ON EACH. TATc • �, %,� p�.•• N5 4/4 �.:' k► wosArEnsuND+Iof NOTICE ''���ATT Illlll ► iA�� C.L.Y. DATE. 5-19-95 REVLETTER JACOBSEN HOMES THESE SPEWCATIONS AND DRAMINDS ARE A ORDINAL. PROPRIETARY. AND OWIDENTUL DRAIG 711M IRE P.O. BOX 368 MATERIALS OF JACOBSEN U&WTAC71ANC TD-GENERAL NOTES SAFETY HARBOR, FLORIDA 34695 RESENT FOR VECEIC SS ARE NO YAT BE DRAWING MUSER. PHONE (813) 726-1138 PM COWIDENTLAL AIo SECRET RIOY OTHERS AD-TD-0001 29 ADDENDUM C NORMAL TIE -DOWN SPACING TABLES Ott 1 ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE „' MIN. WIND ZONE II WIND ZONE III YIN• ott. ANCHOR YIN. ANCHOR FLOOR WIDTH EA. END ANGLE D 6 E END OF ANGLE O ON EA. SECTION YIN. B EA SECTION . Y.N. fl 20'-0' 2 36' 2 45' 24'-0' 2 46' 2 60' 25'-4' 2 1 50' 3 38' 26'-8' 2 1 54' 3 41' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE n WIND ZONE III SPACING DEL DEL HEAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0' 12' 8'-0' 31501 40'-50' 6'-8' 3150b 40'-50' 24'-O' 12' B'-0' 3150 j 40'-50' 6'-B' 3150# 40'-50' 254 12' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 26'-8' 12' 8'-0' 31501 40'-50' 6'-8' 3150 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III UK Ott• EA. END ANCHOR N YIN Ott. EA. END OF ANCHOR ANGLE FLOOR O WIDTH FA SCION YIN.. B EA. SECTION MIN. B 20'-0' 2 50' 2 68' 1 24'-0' 2 70' 3 50' 25'-4' 3 45' 3 60' 26'4 3 45' 3 60' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE 14 SPACING DL HEAD ANCHOR ANGLE SPACING ML HEAD ANOIOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 20'-0' 12' 5-4' 31501 40'-45' 4'-0' 31508 40'-50' 24'-0' 12' S'' 31501 40'-50' 4'-0' 31501 40'-50' 25'-4' 12' 5'-4' 31501 40'-50' 4'-0' 3150# 40'-50' 26'-8' 12' 5'-4' 31501 40'-50' %%% ++EIEITT '-0' 3150# 40'-50' NOTES- - ENGINEER` O ii�4 xx DAPIA APPROVAL 1. SEE AD-TD-DO01 FOR ADDITIONAL REOUIREYENTS. GNST ' .� F ' =APPROVED Q . o'. No BY 2. SEE AD-TD-0011 FOR YAXIIAUY PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE. _ ENE8 5 OF OiA�•:\�v�; INC •��Oj(�•• f[�ERY IUNIfKIUIFD N]E JACOBSEN HOMES ■ NOTJCE: TMESE SPEOMAn0NS AND DRAMNGS ARE MONA, PROPRIETARY, AND CWDENTAL )DUR413.. C.L.Y. DATE: 5-30-95 REV. LETTER: A DRANING TITLE: MATERIALS OF JACOBSEN MANUFACTURING NORM. SPACING TABLES P.O. 80X 368 SAFETY rtiG SUCH MATERIALS ARE FRONDED TO THE 00SEOV W HM DRAN7NGNUMBER AD-TD-00 00 PHONER(813)F726fCIjI.M IJUTOD6FLDENn 30 ADDENDUM���s — ALTERNATE TIE D0'1N SPACING TABLES ZONE R & III/Ea). C LONGITUDINAL TIE —DOWN SPACING TABLE W, FLOOR VWH WND ZONE a WW ZONE N WL ary. u sm NiF �i► semi ANm ANCIE asfl e NOL Nm N1F u a cuai ANm ANGIf WL e 1" 23'-4' 2 54' 3 40" �O 24'-0' 2 54 3 40' 25'-4' 2 60' 3 44' 26'-6' 3 36' 3 46' 31-S' 3 4T 4 41' (SEE NOTE j4 FOR ANCHOR ANGLES) VERTICAL TIE —DOWN / FRAME TIE—DOIVN SPACING TABLE YIN. FLOOR WID1H MAX. EAVE OVERHANG INND ZONE II WIND ZONE NI s wo 3L NEAR lam ANNyIQt ME SPACM � ANN M NQE IS 4' 244 25-4' 26'-8' 30'-8' 12' 12' 12' 12' if 64 5-4' 514 54 54 31501 3154 31 3150 31501 W-45' 40'-45' 40'-45' W-45 4(r=4T 54 5'-4' 5'-4' 64 54 31501 31501 31501. 3154 31501 35-40' 35'-40' 1 35'--40' 1 3T-4O' 1 35-40' (SEE NOTE P FOR ANCHOR ANGLES) - r -� • �� .� O . uTl; r_ 'o I, IV .• s�NA„E0%e NOTES: 1. SEE AD-M-W FOR ADDnmw RWJFSEJiis Z SEE AD--TD-ml.1 Fat MAWS PER FIMTS REQUAiED FOR 1HE IAADS TMWAIW ABOVE 36 TE-IXM DESIGN ON 70 PAGE APPLICABLE M DME IDES ONLY. 4. 1t D MOHOR ANGLE S+M IN THE Off AM CIBNNOT BE ACN M WTA M AN APPROM STAKMR PLAIE. CALL. ) - 215.01 - 215.20 APPROVED BY ,7ua 16,2009 INC: FEDERAL NWIUFACiURED MO■E MNSTRUMON AND SM7V STANDARDS JACOBSEN HOMES � AK M.T.— � VA S orF OBAtNNC'LTERNATE SPACING TABLES "— P.a BOX 368 W. S= IMMadS AK pwoI'm m 1HE sAFePHONE (813) �013846B5 �r � MW AM DDe�� D+Ar�tc N�R�t AD-TD-0010.1 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION ,,Wr ANr T1F-nO N SPAOMM FIGURE 1.0 SEE FIGURE 20 FOR ALTERNATE TIE-DO1111 MMOD TYPICAL CROSS SECTION SHOWING TIEDOWNS SEE NOTE 5 FOR VAMNI HOGHT FIGURE 1.1 SEE FIGURE 5.0 FOR ALTERNATE M-DOIN If1:1; A NOTES:- �` � . C�Cp''' f AW&BY 1. SEE AD-1D-0010 FOR SPACING TABLES ��� ] : • tv \S E O •. 2 SEE AD-M-0010 FOR WANK OF LONGITWAL ME -DON STRAPS REQUIRED. ' Q No ,f +1 Y 1 2w 3. SEE OTHER DETAILS FOR BLOOM (PIER) OUMTITY AND OTHER REDUROAENTS EnIE8703571 INC, 4. SEE AD-TD-0001 FOR ADDITIONAL REWREYENTS - FA I V 5. ZONE 2/EPOSURE V'- 60' MAXANM HEIGHT �'� �J Tr. i KA� rnnARo�ReTYRRAro�f ZONE 2/EXP0511RE V. 44' YAMU HEIGHT � . � REF�� ZONE 3/DPOSURE V.- 40' MAX3NM HEIGHT ����•', O A�P����`� ZONE 3/EXPOSURE V: 36' MAXIMUM HEIGHT �sS�� • . •• • �� `���� NOW& OlNYA11 REV. LETTER: JACOBSEN HOMES TRH SPEcw-Amms AND )RAwm ARE C.L.Y. DATE:- 3-27-95 ORIGINAL PROPRIETARY. AND OONnDEHIIAL DRAWING TITLE. MATEARALS OF JACOI)SFA MRWACIU C FIGURES 1.0 AND 1.1 P.O. BOX 368 NG SUCH MATERIALS ARE PROVM TO THE SAFETY HARBOR. FLORIDA 34655 RECPINT FOR SFWF PURPOSES NO AW HE DRAWING NUMBER: PHONE (813) 726-1138 RAPT CONMEN UAL AID 3=1 FROM OnM AD—TD-0011 32 ADDENDUM RECOMMENDED TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS FIGURE 1.0 �oaaalatoo" G D4 wo • �' F•° • ,i m • 1 ,6 a a9 -4 0 0 •. A,�,: T TYPICAL CROSS SECTION o s ...... SHOWING'TEDOWNS M. Rooasrslaa� na777 o°oioS,AIVAq',�°°°o mom M E (m MOiE PS)' mom ma (sm NOR: P) FIGURE 1.1 (DMGN BW ON es t/r 1—M WO AND se' HQi MINA L S) NOTES: i. SEE AD-ID-001O1 FOR SPAM TABLES 2. SEE AD-iD-0010.1 FOR QUANRY OF UIMR DUL TE-000BI STRAPS RFALARED. 3 SEE OTHER DETAILS FOR BIMIS (PIER) QUANTITY AND OTHER REQUIREMF M 4. SEE AD-7D-0001 FOR AMMONAL. REQUIREIIEHTB. 5. ZONE 2/t I(P=X 'C': 6f IMMUM HNIT ZONE 3/WDAIRE V: 56' MAXIM HNIT 6. *EN ANCHOR ANGLE SHOW ON AD-ID-0010.1 CANNOT BE WIIEVED, INSTALL AN APPROVED STARRER PLATE JACOBSEN HOMES N0S1105i SPOCiU911UUUi M Alm DRAMUi06 ARE gamut. FROFRETARY, NO WffM MTK DRAT6N0 n P.O. BOX 368 MAZE W OF MM F&'RM QIC SUCH VAIUA S ARE FROi = M TIE SAFETY HARBOR. FLORIDA 34695 Im IM FOi sFi OAC KAIi = ND MUST E DRAWING Ni PHONE (613) 726-1136 07 CpIReMK AM SECIT FROM OO< K m NOTE 5 RA IMMI HNIT APPROVED BY ONOO Jtim 16,2009 INC. FEDERAL YWIUFALIINFD HOME CONSTRUCRON AND SAFETY STANDARDS GTD- 215.01 - 215.20 M.T. I DATE 06-04-09 1E FIGURES 1.0 AND 1.1 AD—TD-0011.1 33 ADDENDUM NORMAL TIE —DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III FLOOR MIN. Ott. ANCHOR MIN. OEY. ANCHOR �C WIDTH EA. END OF ANGLE EA. END OF ANGLE O EA SECTION MIN. 6 EA SECTION MIN. 0 12'-0' 2 43' 2 55' 13'-4- 2 50' 2 68' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPAONG DBL. HEAD LOAD ANCHOR ANCHOR ANGLE SPACING HEAD LOAD ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0* 6' 8'4 31501 4D'-50' 6'-8' 3150# 40'-50' 13'-4' 6' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III . MIN. OTY. ANCHOR UK OTY. ANCHOR FLOOR WIDTH EA. END N EA. END O -lox� EA SECTION MIN. a EA SECTION u11t e IN. 1 12'-0' 2 64' 3 47' 12'-0' 3 37' 1 4 33' 13'-4' 3 42'1 3 55' 38' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL HEAD ANCHOR ANGLE SPACING DEL HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG Low LOAD 12'—C 6' 54 31501 40'-45' 4'-0' 31500 40'-50' 13'-4' 6' 54 31501 40'-50' 4'-0' 3150# 40'-50' NOTES END O �•'/����'' N DAPIA APPROVAL• 1. SEE AD-1D-0001 FOR ADDI110NAL REOUIREIIENTS ��``�``�O?�r;�ST�9 �O APPROVED BYE :.Q N0.JLN 2. SEE AD—TD-0013 FOR WJ39UM PIER HOWS REWMED FOR THE LOADS TABuu10 ABOVE. ENE8703571 = 1 5 'a NIP 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT RDEWALL NOT FRONT OR REAR. ' *= I N C, 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS WITH 95 1/2' SPACING 96' MAMMUM SIDEWALL HEIGHT AND 6- MAmw SIDE �: STATI F : O : ��+�.� FLOMlAAXJICn00H?E coalp6mal NO SN[TT sviom I —BEAM OVERHANG (6' OVE m4c; MAX EACH SIDE OF ONq %�`�'•.�/O)QN. '•'\� ``�� JACOBSEN HOMES NOTICE: "I/lI! II DT[sE sKonc THINS AHD DRAMN69 ►RE' 1L11�¢ C.L.Y. DATE: 5-30-95 REV. LETTER: DRAWING 71TLE: NORM. SPACING TABLES P.O. BOX 368 0MONAL. PROPRIETARY. AND OORFIDENTML MATERIALS OF JACOBSEN MANUfACMNG PROVIDED 70 THE / ` a, „ SAFETY HARBOR, fLORIOA 34695 PHONE (813) 726-1138 P SO01 MATER.ALS IRE REmW fOR SPEUX PIFiM AND MAT BE IVT C"[011A no gov ► u OTHERS /F DRAW.NG NUMBER: AD—TD-0012 34 TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS ADDENDUM TIE -DOWN SYSTEM FIGURE 1.2 SBB MURB 20 MR ALT 12 M-DOUR 1fB'fBOD FIGURE 1.3 SO MUM 7.0 FOR 9=13 =-WE U[1lOD 1. SEE AD-TD-OD12 FOR SPACING TABLES AND NOTES 2. SEE AD-TD-0012 FOR QUANITY OF LONGITUDIAL TIE -DOWN STRAPS REWIRED. 3. SEE OTHER DETAILS FOR BLOWNG (PIER) WANTITY AND OTHER REOURDADITS 4. SEE AD-TD-ODOI FOR ADDITIONAL REWIiENENTS 5. ZONE 2/ XPOSURE V. 30' MUM NIGHT ZONE 2/ExPOSIJRE '0': 48• MAXIMUM HEIGHT ZONE 3/EXPOSURE 'C: 28" MAXNAUM HEIGHT ZONE 3/Ef�OSURE b': 60' MAXWJM HEIGHT SEE NOTE 5 FOR MUM HE1Q1T ,r1 C• �OF q��c�2 No. o� 7. 9Nlzfi7n7r,71 ' • s-rA U of APPROVED BY;6L, JAN I # INC O�m�wwowinfwalDi JACOBSEN HOMES NONCE; %AUN LDR�� DATE REV. LETTER 711=THESE SWUATIM AND DRm�i k&MN„ " C.L.Y. - 5-19-95 CRUM PROPRIETARY, AND CaICmuft DRAWNG TITLE: P.O. Box 368 MATERM OF MM UANUFAMIM FIGURES 1.2 AND 1.3 = SUCH VAMIM ARE PROYKD TO THE SAFETY HARBOR. FLORIDA 34695 W O FOR S4= RIt = AND 9W IE DRAWING NUMBER PHONE (813) 726-1138 INFE wNrTotllnu AND sDa+Er TRa oIIT¢I AD—TD-0013 35 ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION cNnwNr. Tlr-now SPACINGS Nµ rcn..r,r... -_ .-..- .- __._ _.__ — - _- - - - FIGURE 2.0 SEE FIGURES 1.1 AND 1.3 FOR TYP. CROSS -SECTIONS) NOTES: 1. SEE AD—TD—OD10 FOR SPACING TABLES 2. SEE AD—TD—OD10 FOR QUANITY OF LONCITUDIAL TIE—DOYN STRAPS REOUIRED. 3. SEE OTHER DETAILS FOR BLOCYJNG (PIER) QUANTITY AND OTHER REQUIREMENTS 4. SEE AD—TD-0001 FOR ADDITIONAL REQUIREMENTS JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 .F tvo. o• EN-B703571 �'�tiDiA�••'V� ; AL NOi7CE U.— BT: THESE SPEQnCAnDNS AND DRAVANfS ARE ORIGINAL, PROPRIETARY. AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACP"G INC. SUCH uATEIMS ARE PRONDIED TO THE RECIPIENT rOR SPECr1C P.000 AND WST BE PUT CONFDENTVL AND SECRET FROM OTHERS DAPIA APPROVAL: APPROVED BYE INC (OGIRlCTA71 wo sum STAIaRB DATE: REV. LETTE C.L.Y. 5-19-95 FIGURE 2.0 A R AD-TD-0014 36 ADDENDUM ALTERNATE TIE -DOWN SYSTEMN ALTERNATE LONGITUDINAL TIE -DOWN INSTALLATION METHODS SIDE N;W OF PAIN FRAME TIE -DOWN STRAP I SEE OTHER DEETAILS ►OR TIE -DOWN STRAP SPECInCATIONS. APPROVED ANCHOR WELDED TO MAIN I -BEAM (SEE OILIER DETAILS SEE W-M-0200 FOR FOR NELOW) TO BE NSTALIEO RADIUS CUP DETALS AT 8L'c FACTORY. (REWIRED INS LOCATIONS (WIN . 31501 WGRAING (DSM) LOAD AND 47251 OLTYIATE LOAD.) ° GROUND ANCHCR ° SEE OTHER DETAILS FOR Siff, ANGLE AND OIiLER INSTALLATION NOTES. FIG URE 2.1 SOLJD HEADER (CR055YELIBER) 3' X 3/4' (= 1/2) •MUST BE LOCATED FRONT VIEW CUT INTO HEADER FOR STRAP ATTAChWEN WITHIN S' OF MAIN (FACTORY CUT) CHASES !-BEAM. rmt SEE AD-7D-0200 FOR I SEE AD-M-C203 FOR RADIUS CUP DETAIL I RADIUS CUP DETAILS (REQUIRED IRIS LOCATION} (REAL RED THIS LOCAION). 1 5'WX• TIE -DOWN STRAP SEE OTHER DETAILS SIDE VJ:VT FOR TE-DOWN STRAP SPECIFICATIONS. GROUND ANCHOR' ° SEE OTHER DETAILS FOR SIZE, y ° ANC.E AND DT..-IER INSTALLATION RG _S. ' /*,,,, FIGURE 2.2 NOTES = tER APFROVAi:;VJ- OAFA A.°PR EOVAL: ENE., • 1. SEE AD-1D-0010 FOR SPACING TABLES 2. SEE AD-M-0010 FOR OUANITY OF LONQ7UOIAL TIE-DOVIN STRAFS REW ED. -O = C t• .i_{.- f 3. SEE OTHER DETAILS FOR BLOCKING (PIER) OUANTITY AND OG£R REOIIREMENTS. 4. SEE AD-TD-0001 FOR ADDIDONAL REDUIREMENTS. /i/ ff 4 At ,rp,rni,n► ``` r - A,\CHOR BRA(XET AND W--DOWN DEICES ARE CERTIFIED BY OW-45 K07TCe GRAWN BY. C.L.Y. DA,c. 6-13-95 REV. LETTER: JACOBSEN HOMES TrEj SPEGACA:'ONS AND CRAWhGS AM OMGNAL. F11CPWART, AND cadmoam, CRAWWG llU Em P.D. aax 36s !f- ACE TMt MATERIALSDF JACMZN MANIfACIU 11G FIGURES 2.1 & 2.2 Sum MAlums mm TO IN: SAFETY HARBOR, FLORIDA 34625 It U10T root rEcnc P"m AAO mfiT E DRAWING. NW8M JPHCGVE (8I3) 726-1130 Avl whnxNiAL AM sanT MOW Oil= AD—TD-0015 : 47 1 LONGITUDINAL STRAP ATTACHMENT TIPICA AM CLAMP, MANUFACURED BY ENGINEERING, PART F 59011 t— ACIURER'S INSTRUC110N5 FOR COMPLETE INSTALLATION DETAILS) TYPICAL LONGITUDINAL ANCHOR STRAP (FIELD INSTALLED) NOTES: DAPIA APPROVAL 1. SEE OTHER DETAILS FOR STRAP PROTECTION AT ALL SHARP CORNERS A P ROVED EY 2. ALL -STRAPS TO BE TYPE 1, FINISH B, GRADE 1 STEEL STRAPPING, 1 1/4" WIDE AND Q035 INCHES IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL 15.20 ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D 3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLIT STEEL, AND SEALS. ! N C. FEDE AL MANUFACTURED HOME CONS rRIIC710N AND SAFETY STANDARDS ji JACOBSEN HOMES NOTICE DRAWN BY: DATE: REV. lET1ER: THESE SPEOFICATIONS AND oRAYANGS ARE M.T. 6-12-01 GRIGINAL, PROPRITARY, AND CMDENRAL DRAWING TITLE: MAIERXS OF JACOBSEN MANUFACTURING P.O. BOX 368' me suety MAIERiALS ARE FRONDED to ME LONGITUDINAL STRAP ATTACHMENT SAFETY HARBOR. FLORIDA 34695 RECIRDIT FOi 9WIC PURPDM AND MUST BE DRAWING NUMBER: AD-TD-0016. PHONE (727) 726-1138 K I CONFR DMAL AND SW TROY OTHOIS. ,an ADDENDUM OFFSET UNIT TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D `3 0� LONGITUDINAL TIE -DOWN. SPACING TABLE MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III WN. CITY. ANCHOR RL CITY. EA. END OF muEll END OF EA. SEctI011 uUKa Ell gcnal ANCHOR ANGLE lulls e 10'-0" 2 44' 2 56' 12'-0" 2 57- 3 4T 13'-4' 3 38' 1 3 50, VERTICAL TIE-DOVN / FRAME TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH MAX EAVE OVERHANG WIND ZONE II WIND ZONE III SPACINGoei� ANCHOR ANaE SPACING DEL. HEAD DEL ANCHOR ANGLE 10'-0" 12' 4'-0' 31501 40'-50' 4'-0' 31501 40'-50' 12'-0" 12' 4'-0" 3DO01 40'-50' 4'-0. 31501 40'-50' 13'-4" 12' 6-3- 31501 40'-50' 4'-0" =I 40*-50! i n r v LONGITUDINAL TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III uRL OTL EA. END EA. sEcnMN moo ANGLE UK 951 OTY. EA. END EA. SECTION AHm ANGLE uDl e 10'-0' 2 64' 3 46' 12'-0* 3 50' 3 68' 13'-4" 3 58' 4 48. VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE WIND ZONE III MIN. MAX. WIND WlL II FLOOR SAVE SPACING DB" HEM ANCHOR ANCLL SPACING DBL HEAD low ANOHDR ANGLE WIDTH OVERHANG LOAD 10'-O" 12" 4'-0' 31501 40'-50' 2'-8" 31501 40•-50' 12'-0" 12" 4'-0' 31001 40'-50- 2'-8- 31501 - 40'-50' 13'-4" 12' 4'-0* 3065,5 40'-50 2'-8" MOM 40'-50' NOTES: ENO'NW jCyAb O A ifAcfLD BY 1. OFFSET SECTION WITH THE MARRIAGE LINE WALL EXTENDING BEYOND THE ENDWALL OF,Q�STD ,• REVISED THE ADJACENT SECTION MUST BE TIED DOWN AT THE MARRIAGE LINE 1N ACCORDANCE Q - $gyp 0 9 i W T H THE TABLES ABOVE THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE T . h' .. •; J , BE TIED DOVDH IN ACCORDANCE NTH THE NORMAL SPACING TABLES (AD-TD-0010). ; � � 3 I N C 2. SEE AD-TD-ObOI FOR ADDITIONAL REQUIREMENTS. -0 `, •� " ` • �0,�;••, �q6r: ' �`� FEDI RAL MANUFACTURED HOME. ��9 3. SEE AD-M-0021 FOR MAIOMUM PIER HEIGHT REOUIRED FOR THE LOADS TABULATED COi Jj� �s '• .. ISTRUCTION AND SAFETY STAND ' ABOVE ``�� NOTICE DALE REV. LETTER: JACOBSEN HOMES THESE SPEonC•TIONS AND ORAL ARE R.R. s-27—ss ORICNAL PROMETARY. AND WN10b111AL DRAMNG TALE: B MkIERuuS OF JACom MANUFACTURING OFFSET SPACING TABLES P.O. BOX 368 W_ 10 NATERULS ARE PROMOED TO THE SAFETY HARBOR. FLORIDA 34695 RMraI FOR SPEOM H RVU AND TART of BRAKING NUMOER PHONE (813) 726-1138 1 VOT COWWfK NO XaV TROU OTHERS AD—TD-0020 39 ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN SPACINGS FIGURE 3.0 SEE FIGURE 4.0 FOR ALTERNATE TIE-DOAN 10HOD TYP. CROSS SECTION(S) SHOWING TIEDOWNS SEE NOTE 5 FOR ANGLE ANGLE FIGURE 3.1 SEE FIGURE &D FOR ALTERNATE TIE -DOWN XMD [TARES ON AD-ID-M ELM APPLY TD TIM STANDARD 1&1LT1-NDE SECBONS OF THE UNIT -SEE NOTE 1. AD-ID-ODM) TYP. FLOOR SYSiDI— ANCHOR MaE ANm ANOIE FIGURE 3.2 1lAsq$, ALTERNATE TD3-Do1PN I4EffloD ENq 0 ° VFO �ii� DAPIA APPROVAL NOTES: .� O 1. SEE AD-m-0020 FOR SPACING TABLES SECTION ONLY). OFFSET Q,G� Na'Q o�'L y'' APPROVED BY (: �• � F •••. 2. SEE AD-TD-0020 FOR OUANITY OF LONGITUDX TIE-DOVIN STRAPS REWIRED. ENE8703rJ71 •: (OFFSET SECTION ONLY) ` 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REQUIREMENTS. _ _7N rfl i` 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. N�, 5. ZONE 2/EXPOSURE 'C': 4e MAXIMUM HEIGHT %9��'•. //tt�': ��1� ��� � HOW ZONE ' v ZONE 2/EXPOSURE V: 24* MAXIMUM HMT (327 0 24' WIDE MIN.) ZONE 3/EXPOSURE OSURE V: 32' 32* MAXIMUM HEIGHT HEIGHT (44' 024' MADE MIN.) �sr�QNAI•�� DRAYN BY: DATE REV. LETTER: JACOBSEN HOMES THESE SPECIFlCATIONN077CE s AND DRAVANGS ARE C.L.Y. 5-11-95 P.O. BOX 368 ORIGNAL. PROPRIETARY• AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: FIG. 3.0 3.1 & 3.2 ' ❑„ DIC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR. FLORIDA 34695 FECFENF FOR SPECflC RWOSES Alm WST BE DRAWING NUMBER: PHONE (813) 726-1138 IOPT CDNFWDAL AM SECRET FROM OTOM AD-TD-0021 An ADDENDUM ALTERNATE OFFSET UNIT TIE-DOtitiN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE —GOWN SPACINGS FIGURE 4.0 SEE FIGURES 3.1 AND 3.2 FOR TYP. CROSS-SECTION NOTES: Er •' ov �., oAP1A AvvaovAL 1. SEE AD-M-0020 FOR SPAC141, TABLES (DFFSET SEC71ON ONLY). )�•��,G% hoF9Fo F.y'' APPROVED BY 2. SEE AD-M-0020 FOR OUANITY OF LOiMWAL TIE -DOWN STRAPS REWRED. (OFFSET sECT1DN ONLY) = L NE8703571 — 5 .L 3. SEE 010 DETAILS FOR BLDOC'tiv (PIER) QUANTITY AND OTHER REOUIRUNTS 4. SEE AD-TD-0001 FOR ADDITIO:Al REOUIREuENTS • __ TAT INC s12.• � � ' 9Q( .. g���. �� nttwtwtJAflvm,Or Wn,R+PD�woYR11fW['Yq JACO BS EN HOMES msE sPconuna S MD oRAVOM ARE ' "'� B C.l.Y. pA1E' 5-11-95 REV. Linut: „ P.O. 90X 368 aaoNAL PROPfEETARY, AI4l OOt/LO Wlm YAIDCAIS OF 1ACOBg7t ,�NAlrACTURWO PRQV= TO TN[ SLKH YA ML TtASA1S ARE DRATANG 11M FlG. 4.Q SAFELY HA?2:�. FLORIDA 34695 PHONE {.13) 726-1138 KCMIT rot 71CM PJW='we KW r PVT ONMRIL APO SEOET TIM OrMM DRAWXG NUYGER: A0—M-0022 ADDENDUM l��g � C��gs SPACING TABLES Ott� ALTERNATE UNIT TIE -DOWN 5. 1t C & D ZONE II & III/EXP. LONGITUDINAL TIE -DOWN SPACING TABLE MIN. VAND ZONE II WIND ZONE III uu+. QTY.ANCHOR HOR uUKDn. ANCGLE FLOOR END OF AN. EA. END or AN. WIDTH EA. SECTION EA. YIN. A EA SECTION YIN. B 4O� 20'-0' 2 46' 2 45' 24'-0' 2 46' 2 60' 1 25'-4' 2 50' 2 67' 26'-8' 2 55' 3 30' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE LAIN. MAX WIND ZONE II WIND ZONE III SPACING DBHEAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCIIOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD 20'-0' 12' 4'-0' 36701 20' 4'-0' 3900# 20' 24'-0' 12' 4'-0' 1 37001 20' 4'-0' 3950# 20' 25-4' 12' 6'-8' Owl 15' 4'-0' 39500 22' 26'-8' 12' 6'-8' 39501 28' 4'-0' 3950# 22' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III r FLOOR �N qn. EA END Cf ANCHOR ANGLE UK Dn. EA. END OF ANCHOR ANIXE R1DTH EA CTION SE YIN 6 EA sEC110N YIN e 2 50' N/A N/A 1 24'-0' 2 70' N/A N/A 254 3 42' N/A N/A 26'-8' N/A N/A N/A N/A VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN MAX WIND ZONE II WIND ZONE III SPACINGDEL HEAD ANGLE SPACING D oHD� AND iOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD 20'-0' 12' 4'-0' 40001 20' N/A N/A _N/A 24'-0' 12' 4'-0' 40001 24' N/A N/A N/A 25'-4' 12' 4'-0' 4000# 26' N/A N/A N/A 26'-8' 12' 4'-0' 40DOI I 2T , ,,,,, N/A N/A N/A NOTES:`<` ENQNF�E41•'AQP{i�ALDO �/,� ....., DAPIA APPROVAL• REWIREYENTS '� 9c�0 .? •� 1. SEE AD-TD-DWI FOR ADDITIONAL n0 _. 2. SEE AD-TD-0031 FOR MAMIUM PIER HEIGHT REWIRED FOR THE LOADS TABULATED E;\E8703571 _ ABOVE: J. = 3. 20 W1DES -82' MAXUW 1-BEAM SPACING ONLY. 4. 4' MAMULI INSET TO ANCHOR HEADS (SEE AD-TD-0031). �'�� `• ,��4� 'Jlhl Nm ,9BAMN' : C.L.Y. DATE 6-13-95 REV. LETTER: JACOBSEN HOMES THESE sPcancATRx+s AND DRAnalcs AM AND OMONAL PROPKTARY. AND CDOWTIAL DRAWING M' ALT. SPACING TABLES P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 MATERIALS OF JACOWN MWACAW'G DIG SUCH NATERu1S ARE PROMDD TO 1NC R[OPER SPEa11C NT FOR PIFPOSTS ADD MUST BE p(tAMANG NUMBER AD-TD-0030 PHONE.(813) 726-1138 mT cmrmrnK AND SEaiET mu onm 42 000� P���°� ALTERNATE_ TDEE a DOWN SYSTEM(S) TYPICAL CROSS SECTION SHOWING TIEDOWNS SEE NOtE 4 FOR YAIAIUY HEIGHT 4. MAX. JLV FIGURE 5.0 SEE FIGURE L1 FOR RECOMMENDED TE-DOLY METHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS IIM USING THIS TE--DONN. CONFIGURATION A OU CRFST PRODUCTS YODEL 57SH (TYPE 21 AUGER ANCHOR 111111 DESIGN LOAD (TOEt M IDID) RATING OF 4,000 POUNDS AND AN U13IMATE LOAD RATIO; OF 6.000 POUNDS MUST BE USED. AN EQUIVZART ANCHOR Fa'EEm THE ABOVE SPE-MCATTORS HARE BY ANOTHER MANUFACTURER MAY BE USED IN IEU OF THIN SME CREST PRODUCTS ANCHOR NOTES. THE ALTERNATE RE —DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN 1. SEE AD—TD-0001 FOR ADDITIONAL REQUIREMENTS. ALL WIND ZONES AND IN801H EXPOSURE 'C' AND EXPOSURE ID'. HOWEVER. BY 'OUTBOARD' INSTALLING, THE FRAME TIE —DOWN STRAPS AT THE I —BEAM THE MAX 2. SEE OTHER DETAILS FOR BLOCIGNG (PIER) OUANIITY AND OTHER REOUIREYENTS HEIGHT OFF THE GROL M IS GREATLY REDUf.ED. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 5.0 SEE ALTERNATE TE—DOWN SPACING TABLES (AO-7D-0030). RECOMMEHOEID WHOOS FOR INSTALLING aTnuu�i,.. FRAME TE—DOWNS. 4. ZONE 2/EXPOSURE 'C': 37C MAXV.UM HEIGHT ENGINEER PROYALyT.• '' DAPIA APPROVAL' ZONE 2/EXPOSURE V. 27- MAWljM HEIGHTZONE ZONE S XPOSURE 'D.-THIS PHEIGHTOU LJCA71ON )d.•'�G1ST�Fy.�!1`4�' IS NOT APPLICABLE. = Not G g J' ENE-M)lF,71 JACOBSEN HOMES TNEsE sPEC6CATCNS ANDD DRAKNGSTARE .�" Vffl 81 C.L.Y. DATE 6-13-95 ` " LETTER: P.O. BOX 368 CO MONAL. PROPKIART, AND W1DE1 R% MATERIALS DF .IACOM MAN NACMUG DRAWING TIRE' FIG. 5.0 \I SAFETY HARBOR. FLORIDA 34695 Mt W0i MAIEIW ARE PROv10ED.T0 TPC RECPDIF FOR VECFX PJMW AND KW BE DRAWWG NUMBER PHONE (813) 726-1138 KPT COWMRAE AND MOO FROM ODM AD-TT)-0031 •43 bN°A 0%3r.0f ADDENDUM s ,LDS ►� �� Fes, �f"0°w� FORS ALT. OFFSET UNIT TIE -DOWN SPACING TABLES 6 ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III NOT. Ott. ANCHOR WIN. Ott.GN ANCHOR FLOOR 'MDlH EA ENO ANGLE EA END OF ANGLE O� O EA SECTIONN MIN. A EA. SECTI MIN. B 20'-0' N/A N/A N/A N/A 24'-0 2 42' 1 2 53' 25'-4' 2 45' 2 58' 26'-8' 2 48' 3 370 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING � HEAD Low ANCHOR ANGLE SPACING DEL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 26-0' 12' N/A N/A N/A N/A N/A N/A 24'-O' 12' 1 4'-0' 40001 20'-30' 4'-0' 4000# 2T-30' 25-4' 12' 4'-0' 40001 20'-30' 4'-0' 4000# 20'-30' 26'4 12' 4'-0' 40001 20'-30' •4'-0' 40000 25-30' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III UK OTT. Lk END ANCHOR ANGLE WIN. OTT. EA END ANCHOR ANGLE FLOOR O WIDTH EA gcnDN MIN. a EA SECTION MIN.. e N/A N/A N/A N/A 24'-0' 2 60' 3 45' v�20'-0' �1 254 2 1 66' 3 48' 26'-8' 3 1 41' 3 52' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DOL HEAD ANCHOR ANGLE SPACING � HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG Low 20'-0' 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' 3'-8' 40001 20'-30' 2'-8' 4000# 20'-30' 15'-4' 12' 4'-0' 40001 25'-30' S-2' 40001 1.5 -30' 26'-8' 12' 4'-0' 40001 25'-30' 3'-2' 40001 25'-30' NOTES: ENGINEER`l��(YVITLEIIIIIIAAAA'' DAPIA APPROVAL: MARRIAGE OF .�� �' •���0�� PPROVED BY 1. OFFSET SECTION MTN THE LINE WALL ETLTENDHNG BEYOND THE ENDWALL SECTION BE TIED DOWN THE MARRIAGE IN ACCORDANCE :�� �� '�S i ''• % '/, RFO THE ADJACENT MUST AT LINE WITH THE TABLES ABOVE THE SIDEW'ALE SIDE AND THE ADJACENT SECTION(S) ARE TO ? ,: •��G No. ? JUN 1 4 BE TIED DOWN IN ACCORDANCE MTN THE ALT. SPACING TABLES (AD-TD-0030). E I •� — INC, 2 SEE AD-TD-OlXI1 FOR ADDITIONAL RE0U60ENTS FOR MAXIMUM PIER HEIGHT REQIARED FOR THE ULA S TABTED ST�r �'. Zr,i Q.'•. L, FIcch- . 3. SEE AD-TD-OD33 LOW ABOVE �� ��`•' a1 �� JACOBSEN HOMES /� I, THESESPEana►na1�SAA1�D.O Zcls'Z. I pa TTL"aa C.L.Y. DATE: 5-30-95 REV. LETTER DRAWING TITLE: ALT. SPACING TABLES ORIGINAL, PROPKTARY. AND OONIMTIAL MATERIALS OF JACOBSEN MMUFACAIRING P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 INC. SR71 MATERIALS ARE PROMOm TO THE REOPOn Fat SpEoFx PUIP(ffi MID WST BE DRAWING NUMBER: AD-TD-0032 PHONE (813) 726-1138 IVT O MMnk LLD SEW FRD I OHM 44 II �E IGA�IS"0E� , ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYP. CROSS SECTIONS) SHOWING TIEDOWNS mu mu FIGURE 6.0 SEE TT M 3.1 MR RECOMMENDED 7IE-DOTN METHOD SEE NDIE 5 FOR MAIOIAAI HE w (TAM am wm-am Ma ABLY U DIES£ SVIN w LAND -ICE lcKNs CF THE UI47 -51E NOTE 1, AD-ID-0017.] TIP. FLOOR SYSILV7 ANoN>a mm TIP. MDICR ANGLE FIGURE 6.1 SEE FIGURE 12 FOR RECOMMENDED TE-DOU METHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS TZ-DONUT CONFIGURATION A SnU CREST PRODUCTS YODEL 57SH (TYPE 2)). AUGER ANCHOR TO A DESIGN LOAD (TOLLING LOAD) RATDNG OF 4,000 POUNDS AND AN ULTDIATE IDAD RATING OF 6,ODO POUNDS MUST BE USED. AN EQIHVI.ANT ANCHOR MEETING TILE ABOVE SPECIFICATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN LIEU OF THE ME CREST PRODUCTS ANCHOR. NOTES: 1. SEE HID-TD-0001 FOR ADDITIONAL REQUIREMENTS 2. SEE OTHER DETAILS FOR DLWONG (PIER) QUANTITY AND 07HER REQUIREMENTS. 3. FOR FIGURE 6.0 SEE OFFSET UNIT TIE -DOWN SPACING TABLES (AD-1D-0020). 4. FOR FIGURE 6.1 SEE NORMAL TIE -DOWN SPACING TABLES (AD-7D-0010). (ALSO SEE AD-TD-0020 AND AD-m-0021) 5. ZONE 2/EXPOSIIRE 'C': 32' MAXDNUY HEIGHT ZONE 2/EXPOSURE 'D% 24' MAXIMUM HEIGHT ZONE 3/EXPOSURE 'C: 24' MAXIMUM HEOT ZONE 3/EVOSURE 'D': 28' MAXIMUM HEIGHT THE ALTERNATE 1E-DOWN METHODS SHOWN ABOW ARE ACCEPTABLE FOR USE N ALL MrND ZONES AND N BODN EXPOAIFf 'C' AND EVOSURE 'D. HOwi4M BY INSTALLING THE FRAME ME -DOWN STRAPS AT THE 'OUTBOARD' I -BEAM THE VAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR 1NSTALLNG FRAME TIE -DOWNS. . No-R�o�y 6NE87035 Sys✓ ROVED BY NIPINC :ya.Iwti:P M-SNIT: i.MO1R� JACOBSEN HOMES DIESE SPECIIICA1rOISS An MANNcs'i Iloa�wH `"� c.�.Y. DATE'5-30-95 REV. MOAT. PR/PrIEUutr, ANO'AWWAlft ORAWING 11E: ,. P.O. BOX 368 MATERIALS OF JACOM MMUFACDIRING nc SIOI MAIUUANS ARE PROM IN To THE FIG. 6.0 dC 6.1 SAFETY HARBOR FLORIDA 34695 . Kmw ►OR SPECEIC Pmm AID wo THE DRAWING NUMBER PHONE (813) 726-1138 IVT CDIFT]OITUL ND Mao rmm onm AD—M-0033 LVA ADDENDUM ALTERNATE TIE—DOWNI SPACING TABLES ZONE lI & III/EXP. C & D LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WAND ZONE II WIND ZONE III '"a. Dtt mom uw. OTY. ANW V t (� FLOOR E END ANGLE EA. END OF ANGLE 4 0� WIDTH EA SECTION YIN. B EA. SECTION lK uNL B -0' 2 43' 2 13'-4' IS 2 50' 2 68' 68' 1 VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE WN MAX. WIND ZONE II WIND ZONE III SPACING D�� A4LHaT ANDS SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG 6' 4'-0' 31501 20' . 4'-0' 39001 22' 6- 5'-4' 38501 25' 5'-4' 39601 30' THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND - ANCHORS LONGITUDINAL TIE —DOWN SPACING TABLE n MIN. WIND ZONE II WIND ZONE III FLOOR YIN. D Y.O EA END of Mon ANGLE ANGLE k OTT. EA END OF ANCHOR ANGLE W10TH Ex s>:cTION wl a E.A. sECTaN uu+. e O� 11 •� 12'-0' 2 64' 3 47' 3 37' 4 33' 3 42' 3 55' 13'-4' 4 30' 4 38' 'VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACWG DEL HEAD ANCHOR ANGLE SPACING HEAD LOAD ANDIOR ANNG CLE FLOOR EAVE WIDTH OVERHANG LOAD 12'-0' 6' 4'-0" 39501 25' 2'-8' 39301 1 20' 13'-4' 6- 4'-0' 39601 25' 1 2'-8' 40001 30' THIS ALTERNATE APPLICATION REQUIRES11I14,,000 POUND ANCHORS NOTES. T1T01h1isIPREUJ.: c OG Q" i,,''' DAPIA APPROVAL 1. SEE AD-TD-0001 FOR ADDITIONAL REOUGtET1ENIS `1J�.,........ `,Q; •�G�STE FOC.2 No. APPROVED BY n1E LOADS �: = 2. SEE AO-TD-0036 FOR MAXIM PIER HEIGHTS REOWTED FOR TABULATED ABOVE ENE8703571 _ 87 _ jo i 5 3. MAX EAVE OVERHANG REFERS 10 OVERHANG AT SIDEWALL NOT FRONT OR REAR. •; INC, 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS 1NTH 95 1/2' ND 6' MAMA SIDE .��••' //vD1 N•,•. ��``�: i n�`ucnarAAos+PETt (OVERHANG MAX EACH SIDE OF�UNIi ����''�t'�S/..'.....• (66'T014RHAN lil Nonce •Fe. pills :. c.L.Y. DA1E 5=3U-95 REV. LETTER JACOBSEN HOMES msE sPEa1uA11oHs AND DRAMNGS AAE OR101RAL PR.OPRk7ARY. AND COtdiD0111AL YANIIFACTUaNC ^ DRAWING TITLE: ALT. SPACING TABLES P.O. BOX 368 r1l SAFETY HARBOR, FLORIDA W95 MATETbALS OF JAC:! NG SUW MATERUES ARC PRO40 TO W AE�NT FOR SPECM PJMS NO MW BE DRAWING NUMBER AD-TO-0040 PHONE (813) 726-1138 IvT mwmrTUL AND 3CAET no ormin 46 ����o�s �000# ADDENDUM ALTERNATE TIE —DOWN SYSTEM TYPICAL CROSS SECTION SHOWING TIEDOWNS ANAit MOLE FIGURE 7.0 SEE FIGURE L3 FOR RECOMMENDED TIE-DOIN METHOD IMPORTANT NOTICE: SEE NOTE 4 FOR MAW N H XHT THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS TW USING TO TIE -DOWN CONFIGURATION A MU CREST PRODUCTS MODEL 573H (TYPE 2� 1UCER ANCHOR WITH A DMGN LOAD (10106 LOUD) RATING of 4,000 POUNDS AND AN ULTIMATE LOAD RAffiN OF 6.000 POUNDS MUST BE USED. AN EQUIM ANr ANCHOR ML3TDNG TIM ABOVE SPECIICATIONS MADE BY - ANOIM W"ACTURER MAT BE USED IN LZU OF THE STYLE CREST PRODUCTS ANCHOR NOTES: 1. SEE AD-M-0001 FOR ADDITIONAL REQUIREMENTS 2. SEE OTHER DETAILS FOR BLOMNC (PIER) OUANTITY AND OTHER REOU UMIS. 3. FOR FIGURE 7.0 SEE ALTERNATE DE -DOWN SPACING TABLES (AD-TD-OD35). 4. ZONE 2/EXPOSURE 'C': 38' YAIOMUN HEIGHT ZONE 2/EXPOSURE V: UOM 28' NAUM NIGHT ZONE 3/EXPOSURE V.- 28' MATOLRUY HEIGHT ZONE 3/EVOSIRE V. 28' NA)aWUM NIGHT 5. SEE AD-TD-0035 FOR ADDITIONAL NOTES JACOBSEN HOMES „ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 THE ALTERNATE DE -DOWN NETHODS SHOvm ABOVE ARE ACCEPTABLE FOR USE N ALL MIND ZONES AND IN 807H LXPOSURE V AND EItPOSURE '0', HOWEVER, BY INSTALLING THE FRAME ME -DOWN 57RAPS AT THE 'OUTBOARD' F-Km THE MAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR IfSTALLNC FRAME TIE -DOWNS. NOTICE' -•gihf T1ESE SPEOMT04 AND DRAW= ARE CRIDWAL, PROPRETARY, AND COIEFDOnK MATERINS OF,IACOBSEN MANLFACTURMO W- SUCH MAMALS ARE PROMRD To THE ISA.TPDIT Fat SPM RIM'OSES NO WM N 01 CCN MRAL AND SEOET 1Aaf OTTERS C.L.Y, APPROVED BY IAo�5 ING coo .. u.,iuwmlwnAo� 5-30-95 FIG. 7.0 A AD-TD-0041 47 ADDENDUM MISC. TIE -DOWN PROTECTION OF STRAP IS PROVIDED AT UPPER CORNERS BY FIRST WRAP OF STRAP. FRAME TIE -DOWN STRAP SHALL SEE DETAIL 'B' COME OFF THE 'TOP' OF THE I -BEAM SEE DETAIL 'C' DETAIL 'A' IUCKLE WITH 31501 Y MINIMUM (DESIGN LOAD) DETAIL I PULL DOWN TIGHT TO GROUND ANCHOR INSTALL RADIUS CUP (SEE AD-TD-0200) OR SIMILAR DEVICE TO PROTECT STRAP .AT ALL SHARP CORNERS. Am=* DETAIL T C' THIS TYPE OF PROTECTION MAY BE USED FOR ;q,3q ,,AT LONGITUDINAL TIE CONNECTIONS ALSO. ttLV,Mbd nrncyv�o.: - •TF :'Q N NOTES: o. o'••. = APPROVED PY 1. SHOWN ABOVE IS ONLY ONE METHOD OF STRAP ATTACHMENT = 910334 AT BEAM -OTHER METHODS THAT ARE CERTIFIED TO MEETT-qA THE REQUIRED DESIGN LOAD OF 3150# MAY BE USED.2. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS" '° = STATE OF WHERE THE ANCHORING SYSTEM REQUIRES THE USEOF EXTERNAL STRAPS OR CABLES (SEE RADIUS CUP). '�i�` .I' � NN �r�z • ME D AND OTHERS NOV 2 4 1998 NOTICE` DRAWN BY: DATE Kv• LEVER: JACOBSEN HOMES THESE SPEOFICATIONs AM DRAWS ARE M.T. 11-18-98 ORONAL PROPRIETARY. AND O7NFMnAL DRAMNG TITLE. P.O. BOX 368 B MATMmS or JACOV" MANUFACTURING MISC. TIE -DOWN NC SUCH MATM&S ARE PROVDED TO THE SAFETYARBOR,;FLORIDAG3334695 REMOT ORS OM K" AND T BE DRAWING NUMBER: AD—TD-OOSO Li 48 ADDENDUM �s NORMTIE-DOWN AL SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III vU+. QTY. EA. END OF U SECTION ANCHOR ARGLE YIN. oTY. Ell DO OF ANCHOR ANGLE FLOOR WIDTII O a MIX B Ell SECTION WL 0 30'-8' 3 40 3 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX ----I WIND ZONE U WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING D9 0r "'30 ANGLE SPACING D WA ANCHOR ANQE LOAD 30'-8' 6' 6'-9' 31 41-46 5-5' 31501 44-49 LONGITUDINAL TIE -DOWN SPACING TABLE MIN. V11ND ZONE U WIND ZONE HI FLOOR uul on ANCHOR MUL QTY. ANCHOR WIDTH Ell END OF ANGLE Ell Eta of ANtiE OEA. SECTION MIN. B Ell SECTION UK 9 4 42 4 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE U WIND ZONE IU FLOOR WIDTH EAVE OVERHANG SPACING D, HEA LOAD ANCHOR ANGLE SPACING 08i� AN= ANQE 30'-8' 6' 4'-6' 31501 46-50 4'-0' 31501 49-52 WINWONE III (110 MPH) 20 PSF ROOF 10 PSF D.L.REF. CALCS. G 4/4_ p14. GI ' q¢. (a7 �alunlwn,�A� CITES: Fly 'i��i DAPU 11PPROVA(,�,, MAn 0 1, SEE FULL ADDENDUM FOR ADDITIONAL REQUIREMENTS(y�•-G�STFR e No. 0 % APPROVED BY 2. SEE AD-1D-0071 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE _ 910334 =ON -„*• C- TAT E OF' �� = • ` ^ I� 14 INC. ��;•• : HI V . �• •:, 0 �.` rta�uw„r�,uKowE odanuaau�osunrsmo��a JACOBSEN HOMES Nor1c LH:a1uTloNs AM 11RAMgCS ARE AWN BY. M.T. DATE: 2-8-99 RV. tEtniC ■ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 ORICIN MAWRI1• OF JA[TART• AND CaFI0EN11AL � R OF �YM u ai DRAWiNC TITLE: NORM. SPACING TABLES PHONE (727) 726-1138 KCRINT MR =M FWPM AM UK, �L IQP1 CWWDaM NO Won IRw onM DRAWING NUMBER AD-TD-0070 49 ADDENDUM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS TIE -DOWN SYSTEM FIGURE 10.0 SU ECUM 2.0 MR AL9EIOIATI, 75-DOW MOD TYPICAL. CROSS SECTION I I III SHOWING TIEDOWNS TV. ROCR snU-7 TV. aDss'mam SEE NOTE 5 FOR MAXNUM HEIGHT YLI .fir .fir N ANOHOR ABLE ANCHOR ANGLE SET ANM FEAR WINEIZONE III (,gym FIGURE 10.1 (110 MPH) or SEE FIORE &0 FOR ACIERNATE Urr-DOWN YETBOD 20 PSF ROOF 10 PSF D.L REF. CALLS.wfJ, �/� Gl•— 9/- !Ho NOTES: �5 1 E •'' �,�! '�.� v c DAMAPPRovAI:. 1. SEE AD-TD-0070 FOR SPAM TABLES, .` _; :'eNo. �o'•• APPROVED BY ISEE AD-111-0070 FOR QUALITY OF LONQNDIAL X-DOWN STRAPS REWIRED. 910334 * _ r 3. SEE OTHER DETAILS FOR BLOMNG (PER) QUANTITY AND OTHER REOUREMENTS. * • o®� - OF ' 4. SEE FULL ADDENDUM FOR ADDITIONAL REOUFBEMENTS 5. ZONE 2AXPOSURE V. 56- MAM N HEIGHT =.-0STATE �Q•'•.,/ �P. ���'cCHINC. �; .� . NDIA.. .. ZOHIE 2/E)POSURE b•: 40' YA>QYUY HEIGHT ii ��i .` ZONE 3/E)POb1XRE V: W MA)DMUM HEIGHT s,. `�� mjsT 0im05gmsrM°"�S ZONE 3/bPOSURE V.- 40' MAXIMUM HEIGHT ����� a� c }: AuA JACOBSEN HOMES NOnm TNESESKOMMsAND�► ARE DRA M.T. DATE 3-1-99 REV. LETTER: P.O. 80X 368 MMAL. PROPKTARY. AND COWULN Fm 1A11°°"LS OF J%COB" 1MWC DRAWING TITLE FIGURES 10.0 AND 10.1 SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 - qG RKH MAIM" Alai PROW= TO 1 E REO W FUR SPECFIC PIRIPM AND MUST BE ITT Oust Wft AND ZM FROM Mn DRAWING NUMBER: AD-TD-0071 50 ADDENDUM. is � �1GUR 3 NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D 1� LONGITUDINAL TIE -DOWN SPACING TABLE r' � MIN. WIND ZONE q WIND ZONE 61 FLOOR at on ANpIOR on 0� WD1H EA END OF ANGLE Ell END DF ANGLE EA SECTION MR B EA. SECTION WL B 15'-4' . 3 45 3 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. FLOOR MAX EAVE WIND ZONE II WIND ZONE III ' WIDTH OVERHANG SPACING DBL LAD RIM AKE SPACING OBL HEAD FOR ANGLE 15-4' 6' EACH SIDE 6'-10' 31501 40-46 5'_6' LOAD 31501 42-47 LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III FLOOR uIK aTY ANpIOR unL ott Mon WIDTH EA. END OF ANGLE EA DO OF ANGLE S.� Ea sEcnoN unL a Ell sEcnoH LeH, e 15'-4' 3 30 4 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX N1ND ZONE T FLOOR EAVE HIND ZONE lu WIDTH OVERHANG SPACING DB OAD MOO ANCIE SPAONG DBL HEAD AKHM WE 6' EACH SIDE 4'-6' 3150p 42_50 Low 4'-0' 3150� 44-50 14INUCINE III (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALLS �, Av>7 -� n. Gr - 92 , �G NOTES: .G ENGvW OV r �ii� DAPIA APPROVAL•MM 1. SEE FULL ADDENDUM FOR ADDITIONAL REWIREMENTS. .`��` Q� 2. SEE AD-TD-0073 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS ' Q� N�' APPROVED BY TABULATED ABOVE 910334 I. MAX SAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR. � ��® •' * - 4. ABOVE TABLES APPLY TO 184' FLOOR WIDTHS WITH 95 1/2' �'•,• STATE OF lNf4lNC- OVERHANGI-BEAN SPACING, 96' NIJOMUM SOEWALL HEIGHT AND 6' MA70MU11 SIDE'�•P.''�� (6' OVERHANG MAX EACH SIDE OF UNIT). �����` itattatewuAcruAETI�dE ' �f•' pJ16iRYCIIP1M0iAIETftINo41101 i NOTI llll amw BY: DATE: REV. LETTER: JACOBSEN HOMES THESE SPEanCATIONS AND DRAMM ARE M.T. 2-8-99 ORIMNAL, PROPRIETARY, AND COWIOENOAI DRAWWG TITLE - SAFETY BOX 368 WERIALS OF KCOgyNUF tN MAACTURING SAFETY HARBOR, FLORIDA 34695 PC Sua °AMaALS AK PROV&D To Ala THE . NORM. SPACING TABLES PHONE (727) 726-1138 �PT CDiNTLjLL iD+tn D sEatv S� w� DRAWING NUMBER: AD—TO-0072 51 ADDENDUM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING -TIEDOWNS TIE -DOWN SYSTEM FIGURE 10.2 SEE FIGURE ZO FOR ALTERNATE TE-DOWN METHOD s SEE NOTE 5 FOR MABMUM HMT N FIGURE 10.3 NANWONE III OF HOME (TIP.) (110 MPH) SEE FIGURE 7.0 FOR ALTERNATE TEE -DOWN EiMD 20 PSF ROOF 10 PSF D.L REF. CAW& NOTES;.. ".r�' � - -: 1. SEE AD-TD-0072 FOR SPAM TABLES AND NOTES No. � �� •��'�STEgF .`! -,�� APPROVED BY . Q o �• Z SEE AD-TD-0072 FOR QUAMTY OF LONGITUDIAL TE-OONTI STRAPS REWIRED. 910334ON r 3. SEE OTHER DETAILS FOR BLOCKING (PIER) WANTITY AND OTHER REQUIREMENTS. 4. SEE FULL ADDENDUM FOR ADDITIONAL REQURDMENTS .p STATE CF :'� PA 5. ZONE 2/D RE 'G': 56' MAKOMUM HEIGHT �f Q' ' �JCv � � INC. C. ZONE 2/EXI'MK V- 56' MAXIMUM HEIGHT : pif`�; �. D I A�. ��`� Z/ OP�I�ICFy1NOMli1►IiaYM01 ZONE 3/0POSIIRE 'C': 56' MAXIMUM HEIGHT ZONE 3/EPOSIN V.- 56' MAXIMUM HEIGHT S ' � � " 4. A104 NOTICE Y M.T. DATE 3_1_99 REV. LETTER: JACOBSEN HOMES msE SK�Tos AwDRAW14 AM ORIGINAL PROF FJUARY. M 00NI'mc 1TIAL DRAWING TITLE: P.O. BOX 368 N OCE MAWMALS OF dACO�N MANUFACI INC FIGURES 10.2 AND .10.3 W_ 9" MATEAULS ARE PROM= TO THE SAFETY HARBOR. FLORIDA 34695 MCPST FUR SPECK RMPM AND MUST BE DRAWING NUMBER - PHONE (727) 726-1138 *R WNRNOTIIAL ANo SEMS RM UMM AD-TD-0073 ADDENDUM 5 OFFSET. UNIT TIE —DOWN SPACING TABLES ZONE H & III/EXP. C & D I'I LONGITUDINAL TIE —DOWN SPACING TABLE MIN. VINO ZONE it WIND ZONE M P FLOOR W+. of. ANCllpt IK OR ANCHMI WIDTH EA 00 OF ANGLE EA END i ME II I I �O EA sECT1011 WL 0 EA ICU MIL 0 12'-0' 3 4T 3 614 IS-4' 2 54' 3 41' 15'-4' 2 54' 3 41' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE I WIND ZONE III WIDTTH OVERHANG Lm ANQiDR ANGLE SPA01G LM ANCHOR ANLiE 12'-0' 12' 5-0' 31501 40' 4'_p• 31501 '39• 12' S-0' 31501 41' 4'-0' .30001 40• 15-4' 12' 5'1 31501 43' 3OW1 42' it LONGITUDINAL TIE —DOWN SPACING TABLE lil MIN. WEND ZONE I WINO ZONE NI FLOOR Nn arr. AHM wt W. ANCHOR WDTH FA END OF EA iOF EA sEEAON L W. a S Ell ON � sEC'DD L AL 9 12'-0' 4 45' 4 60' v� fl 13'-e 3 45' 3 60' 3 45' 3 60' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WINO ZONE I WINO ZONE e FLOM MOTH01 RHANG SPACING DIL WA lwm Aw SPACINGIn � man ANGLE 12'4 12' 4'-0' 31501 40. S-T 3000i 38• 13'-e 12' 4'-0' Lp U51 41' T-0' 3000/ 39' j 15-4' 12 4'-0' 3 43' 3'-0' 30001 41' NOTES9 cAcUS, g • 1 L ENaW AP" •0,,, REF. cALcs G► -- U- 1 77 - P� OFFSET SEC11oN w1H THE MARRIAGE LINE WALL ExTENDNG BEYOND THE ENDwM1 of �'�� G;•DQ�gl• , 17, THE ADJACENT SECTNIH UM BE TO DOWN AT THE VNIAGE LINE IN. AMMANCE �c•r��►�1F��,• .•' �t�.y�i�. I iVV tD BY WIN THE TABLES G ABOI& THE SIDEWAIL SIDE AND TIE ADJACENT SECTION(S) ARE TO : ' l�•; BE TIED DONN IN A OCORDANCE TN1H '1HE NOR1W. SPACING TABLES (SEE AD-TD-OOTO JU� FOR 0' If-t 13'-4' WOES, AND AD-TD-0070 FOR 15"1 1110% 2 SEE AD-TD-D001 FOR ADDITIONAL REaUIR 31ENTS I TD-0081 FOR IIA)OMIHI PER HEIGHT REOURED FOR THE LOADS IABULAIED s•. �OR,�P •�.�Q`i., INC. ABM•• •• • MANUf LIMI NOME JACOBSEN HOMES »" �,► �''� ����+``'I�LT. 6-8-04 'x'L ` QWK"I• FINFIMMY. AM MAIM HILL PA. BOX 368 IA�Ats OF \/ M SM IIAlE M ARE m SET SPACING TABLES SAFETY HARBOR, FLORIDA 34695 NWW FIR SI = AIMMO AD � PHONE (727) 728-1138 IT0AL T C061118 AND Sk7ylE1 - —p()80 ,,53 ' °• ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SI10YV1NG TIE -DOWN SPACINGS FIGURE 11.0 so FISQRR 4.0 MR eL1>IMI R W-MV 1I=D TYP. CROSS SECTION(S) SHOWING 1IEDOWNS SEE NOW 5 Fat MUNIIII Wit [TARES al AO-1D G080 DUE APPLY 10 DER Sr mRm MlD-USE SE>rm OF DE WT -SFF NDD:1, AD-M-00K) nP. FLOOR SYM--7 v 1--- ANQId1 Al m —I It or I— AN a MaE AMdFF. AM �6*. eq",f6,. FIGURE 11.1 c-sv- J(,6i - 14, a m HIM &8 FOR ALt8R2iAfR m-mv s® TIP. �!juc4 FIGURE 11.2 64 [OR uMOus st40111r ODD NO U71TIR}Y� Q. *-p DAPIA APPROVAL 1. SEE AD-m- = FOR SPAaNG TABLES (OFFSET SECTO aHll� ^~" kit . ... F 1 C • •;�''��� P P R OV E D BY 2. SEE AD-M- = FOR OUAMTY OF LONa11D1AL lE-DOWN STRAPS REW10. (OFFSET SECTION MY) 0.00454 j U N I 1 20 3. SEE OM DUALS FOR BLOOONG (PER) oUAN11TY AND OTHER REOUNt OTS. ' 4. SEE AD-TD-0001 FOR ADDIUONAL REOMBA NTS. •� OF� i w INC. C. 5 IONE 2/EXPOSLIRE't:: 48' MAXWY HOW' p �: .•' ERAL NUFACTUREOHOME ZONE 2/0POWRE V: 40' MAXIMUM HOW-36' FOR 12'-0' WIDE UMTS ��� (� : o {l10 p y RUCTIONAND SAFEfY STANDARDS ZONE 3/EXPO6URE 'C': 4I!' MAXNUM HEIGHT �'•`...... • ��• ZONE 3/E70'OfitARE V: 40' MAXIMUM HEIGHT '►._ �Fn C!1 T `' ..�� NOTICE ''t :R :'Wm M.T. DAM6-8-04 REV. lE1lFR: JACOBSEN HOMES nM S'ECF71:J1IM AND ORAVM ARE CROW., PROPI UMV, AND CQFMIM WAWA nnE: n P.O. eox 3es MAC OF JMOM MNAEACMM FIG. 11.0, 11.1 & 11.2 tH_ 9101 MAD9DNS ARE PRWXO W DE SAFETY HARBOR, FLORIDA 34695 RUM FOR SPEfi1C RWO0 AND ME K DRAIM NUMBER: PHONE (727) 726-1138 IDPT ODita IAL AND XXI FR01 OHM AD-TD-0081 54 ADDENDUM ALTERNATE OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE —DOWN SPACINGS FIGURE 12.0 SEE FIGURES 11.1 AND 11.2 FOR M& iZO: tnwnt 1. SEE AD-TD-WW FOR SPACING TABLES (OFFSET SECTION ONL4 4 •�.,.% 2. SEE AD-TD-ODBD FOR OLIANITY OF LONOITUDIAL. TIE -DOWN STRAPS REOUGIED. if910334 (OFFSET SECTION ONLY) * ®es I SEE OTHER DETAILS FOR BLOCKING (PIER) OUAR71TY AND OTHER REOLIMMENTS. STATE 4. SEE AD-TO-Wol FOR ADDITIONAL REOUIRENENTS. r '9� •'.• P JACOBSEN HOMES TWX SKOIICATIONSL" WAVA CS ATE ORMPL PROPRTFTARY. AND oo1sWIAAL P.O. BOX 368 WERIALS OF ACOO M MANWAC1lNWO SAFETY HARBOR, FLORIDA 34695 W_ SUCM RAIDRALS ARE PMKO TO 1NE . It PHONE (727) 726-1138 �a1aYWIVA AM CK s�AND OTHERL SEE CACGS', �G, SECTION .TION AND SAFE Y ST:,'IUrhaS R.R. ---- 5-9-01 FIG.' 12.0 AD—TD-0082 l 55 ADDENDUM GVg�s SPA ING TABLES ��'�'� 1� 108" HIGH SIDEWALL TIE —DOWN 10 ZONE II & HI/EXP. C & LONGIT INAL TIE —DOWN SPACING TABLE c (+� MIN. WIND ZONE N WIND ZONE N WL on Mon wK on ANOM V FLOOR W1D1H EIRD ff ANGLE Ell sm OF ANGLE sEcaoli � e Ell SFcnou H1L e 3 42' 3 53' �1 30'—Ir 3 52' 4 45' VERTICAL TIE —DOWN / FRAME TIE —DOWN I SPACING TABLE MIN. MAX WIND ZONE I WIND ZONE W SPAM BEL NE ANCHOR ANGLE SPAM WL W AN01GLR ANGLE EAVE WIDTH OVERHANG LOW 26'-Ir 6' 6'-8' 31501 40 -50' 5-4' 31501. 40 -50' 30-8' 6' 6'-8' 31501 40 -50' 5'-4' 3150t 40'-5O' LONGITUbINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE N WWD ZONE MI OT1: END ff GLID ANR ANGLE N8 olY EA. W ff AN01GLt ANGLE FLOOR YMOTH �Q O� SECDON 1!L O EA SECIIGLI UK 9 26'-Ir : 4 41' 4 57 4 51' 4 70' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MR MAX. WIND ZONE A WND ZONE M SP'I NEW �LOADD ANOIGLR ANGLE SPmw VEL ANO0 ANGLE FLOOR EANE WIOTH OVERHANG LOAD 26'-81 6' 5'-4' 31501 40'-50' 44 31501 40'-45' 5-4' 3150E 40'-50' 4'-0' 31501 40=45' YNNKONE N1 (110 MPH) 20 PSF ROOF 10 PSF D.L REF cxcs NOTES: EN i DAPIA APPROVAL: APPROVED BY 1. SEE ROLL ADDEK= FOR ADDWAL REOIAREMEN1T NE,,. 0045484 4 2. SEE AD-M-M FOR MAWN PIER HEIGHTS FFQURED FOR THE LOADS DU. TAM ABODE. .t �� F� •., ;OR1-rN �•' �. FEDERAL. MANUFACTURED HQUE ...•'� r�''1sTEREDENG\��: CONSTRUGnONAND SAFEPisrAN0ARU5 JACOBSEN HOMES NOW& HIM SPEMCA,1SAMWAUMARE DRAIN Im. M.T. DATE_- 07-20-04 REv LETTER: DRANNG DINE' 108' HIGH SIDEWALL SPAaNG TABLES u m m. PROPI umM me aww0 A- "AIUMS OF OZOM UNWAM M P.O. BOX 368 IG mm YAEAAIJ AM FMrAXD 101E DRANNG NINIBER: AD—TD-0083 . SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 XWW fal 9 M NffW MID mg E IOPT tofioe na NO 9W FUN OHM I 66 ADDENDUM TIE -DOWN SYSTEM TYPICAL .SIDE ELEVATION SHOWING TIE —DOWN SPACINGS FIGURE 10.0 TYPICAL CROSS SECION I I SHOWING iIEDOWNSTip • cool man AI1aE TV. moo AM9E SHE NOW S F0t VAXIM NM xo� FIGURE 10.1 (10 � " 20 PSF ROOF 10 PSF D.L REF. m I S. (- - 2 3 1 SEE AO +7 O .••• (IF • DAM APPROVAL• -ID -M I N SPAM TABLES • �; c��' APPROVED -BY 2 SEE AD -TB -OW FM W MTY OF LONGI IX X-000 STRAPS KOLIAED. 1 SEE OTHER OETAIS FOR LLODW9 (PER) OUANTRTT NO OM MOUfi0iE11TS 4!1 SEE FULL AODElp N FOR ADMIONAL REOURE4E?MINrp�•� ZOW 210WO&K V: 36" MUMLIM HEIC HT ZONE 2/EXH'051HRE b•: 2T MAX6Klt1 FpHGHT o "� � Q INC. zw 3/E IRE V. 36' NAXf S HEIGHT ZONE 3/bPOS11RH: V- 32• NA>QM HEIGHT ,��+, _ ,�♦ �• `OF1 •'' •� C/��'••...;..!• ♦♦ •., aT �� FEDERAL MANUFACTUREOHOME CONSIRLIC71ONAND SAFE1YSTANDABUS 6 ALL SPECIFICATIONS ARE BASED ON 2O' ROOF ANGLE dAx. &I 1�2004 r JACOBSEN HOMES T►=SR==N GRATi1i W �' �' M.L DATE: 07-20-04 KY. LEM ETIWI P.O. BOX 368 s """ FMM MA" � `�'FIGURES 10.0 ANO 10.1 SAFETY HARBOR. FLOF40A 34695 IK �R � � N6W0 EST K DRAMtIG !UI ER PHONE (727) 726-1138 ITT OncloEr K W SM Boy OKK AD_jD_OM w ADDENDUM �oR 108" HIGH SIDEWALL TIE -DOWN SPACING TABLES 1� ZONE II & III/EXP.. C & D LONGITUDINAL TIE -DOWN SPACING TABLE (+' ON. WIND ZONE 1 WIND ZONE II \! FLOOR ' WL Orr. Area ox Ott A11m ri101H _ FA ENO OF M Eel W OF Anal: EA SE= ILL D EA SEcnw WL B 2S-4' 2 58' 3 43' 24'-0' 62' 3 457 -- VERTICAL TIE -DOWN FRAME ­ TIE -DOWN SPACING- TABLE . N& MAX _ WND ZK 1 WIND ZONE N SPAOX ML WA LDAD mm ma SPAOIG Del " . LOAD ARM ARQE FLOOR YADTH SAYE OVERHANG 2T-4' 69. C-8' 31501 49' 54 3150 45' 24'—O' 6' 6'4' . 3150 49' 5=4' 3150 45' LONGITUDINAL TIE -DOWN SPACING TABLE t MIN. WAND ZONE I ZDNE II UK OTE mm UK Ott mm FLOOR �Q WIDTHEEA EBD OP DO tK ME �t A SECAON MR Q . ECII01 EADL S YYL IX i 23'-4• 3 48• 4 43' ��\v\ 24'-0• 3 57 4 45' I VERTICAL TIE DOWN / FRAME TIE —DOWN SPACING TABLE WIL MAX WIND ZONE 1 00 ZONE 19 SPA= �- H AO mm mm SPAONG IEAD AMM MOLE BOOR EAVE YADTH OVERHANG LDAD LOAD 23'-4' 6' 6-4' 31 - 4T 4'-0' 31 43' 24'-0* 6• 54 31501 47' 4'4' 31501 4Y lOr MAX. 9DEWALL HE]CHT WINOZONE 11/14 (110 MPH) 20 PSF ROOF 10 PSF D.L R. CALM NOTES: DAr�1A AeeRoviu FULL FOR ADDIAONAL REWRDJUM IL G`j` 9 ,•✓ J APPROVED BY 1. SEE AMMUM A : ON 2. SEE AD-m-mm F0± YANN PIER NElf 0 REOLM FOR THE LO ti � {mot Dec• 13,2006 TABUlJ1TE9 ABOVE. s . d ` INC. i d �� fi •/� V '�`/`�. FEMMM NW COSSiR11CI10N AMD SOFFIT STANDMDS O 14%0 .• ' JACOBSEN HOMES NOTiCIET a671 TmMMAUS� ARE Br: R.R. OAIE: 11-28-06 REY.lET1EFl 11M 108' HIGH SIDEWALL SPAaNG TABLES r.m Box 368 CM=AL FFCWI TML AID CUNFWu DRAMNG MAMAS OF AIC0M MANWACOMM W_ IM RAWIAS AK PM40 to 1K BUIIBER: AO-M-0085 SAFETY HARBOR, FLORIDA 34695 PI+oNE (�27) 72s-n36 PBiW IM SRLTIC XWOM AIO UAST K DRAYNG �oT Cw"wfti at saa P= go= 58 TYPICAL SUE ELEVATION SHOTiONC DE —DM SPACIM . TYPICAL CROSS SECTION SHOWING TTEDONNS ADDENDUM TIE -DOWN SYSTEM TV. ROAR FIGURE 10.0' TV. OM-FDMR ®� ISFE NOFE S FE R tAAAAI N[Z?IT ANDIM NW W AFFW8 NANO -- K'V= MIN ANDU 9lA T V3KAL WWDZOHE Up . . FIGURE 10.1 (201 F7 F� 10 PSP O.L IF CALM NOTES:�Q<1rdA+ 1. SEE AO-10- Ot5 FOR SPAM TABLES �• �=f1r� j •. df DApA ArPIiOYAI: APPROVED BY Z SEE AD-M-038S FOR GUARm OF LOWTuaAL K-ODAW STRAPS NEOUIRU. : G f ` N00 ON. 0 !. SEE OMOETAIIS FOR BLOOM (PER)) GUMnTY AND OTHER REW RLTIE M 4. WE M AQUMU FOR ADWIOR& REOIANEM01M : Dec 23,2006 p r S ZOK 2/0PDSURE •Y 44• HAMM NXK ZDK 2/0POR K T. 2r MATTINAI HEIGHT = N C. _ .. . / lD.6: ZONE 3/E1�OSi1RE 'C: "' HAMMA1 HEIGHT • ZONE 3/E7I►OAtRE bt 3r MAX" HEIGHT 1 : •'n � � ., F, A .' (� ; Fmm m~ACnWD IIr COM51nICf1ON AND SUM STAll"m 6. Ali SECPUTOG ARE BASED ON20' ROOF ANQE MAX NO10E" MAX 90EWALL HEIGHT. o. �+ip :�Giti•�.• � y4. % 41 JACOBSEN HOMES NOTTC>: obit OE!V0X=VWM INAMIM AK Ito . E R.R. GATE 11-28-06 AE>L IETER ORANM law ' FIGURES 10.0 AND 10.1 01KNAL ASgrt+s VJM AN wflOOmq Wlulms °i1CO11AM1iAC"c \� P.D. BOX 368 w_ &a MAIWARS ARE MOM TO TN[ DRANK NUWM- AO—M-0086 SAFETY HARBOR. FLORIDA 34693 PHONE (727) 726-113E K"r Km WIVE mrom BC mu K K►1 CWMDtt no 2w n0Y WK 59 ADDENDUM (108 PIDEWALiG) KOR ZO�EiE1I mD BLEB 1%EXP diGN & & LONGITUDINAL TIE -DOWN SPACING TABLE (� viN.• Own B BIND ZONE u OTT: s Oh. a SEitiGl( FLOOR V�V wk B 12`-0` 2 53' 3 40, 3 37' 3 46' 15-4` 3 45' 4 40' VERTICAL TIE -DOWN / FRAME TIE -DOWN PPACINO TABLE �iN• VAx fAD ZONE tl 00 ZONE NI NMI Am,SPADIyc u AM,{? ' ODTTHH OVERHANG 12'-Ol 6' EACH SIDE 5�-4' 72` 35' TO MY S-4' 38' 45' IS-4' V EACH SIDE 1 5'-4' 80` W TO 40' 54 42' 45 154 6` EACH SIDE 1 T-4' 80` 40' 54 46" 45 LOWI►PUDINAL TIE- DOWN SPACING TABLE INNow ZONE if W ZONE IN Ek ft OF gal EA op DF • FLOOR „ Ek SECTIdI �(• 9 Ek SECAON e 3 44' 4 40' 13'-4 3 52' 1 4 45' 1514 4 44' 4 56' VERTICAL TIE -DOWN / FRAME TIE -DOWN OPACINO TABLE IVAX D ZONE 1 0 ZONE 11 SPADING Vix plTER A►(a hm' 91A* VAX m Alow A190 FLOOR MOTH SAVE OVERHANG 12'-0r 6 EACH SIDE 4'-0f 72` 37' 4'-0' 340 40' TO 45' 13'-4' 6 EACH SIDE 4'-0m 72` 140' 1 4'-0` 38, 40' TO 45' 15-40 6' EACH SIDE 4'-If 80 40' 4'-If 1 42' 1 40' 10 45' • NOTE: WHEN ANCHOR ANGLE FROG( VERTICAL CANNOT BE REF. CALLS, ACHIEVED. ADD APPROVED STABILIZER PLATE. {SEE NOTE 15 FOR HOMES SET IN FLORIDA) NOTE. 1. SU fULL FOR AWTIONAL REOlAREMT& EN R .,�CL1 r, �+fe.�C _ +:jr•:/ f� s • . ��, ✓ON DAM APPROVAL; APPROVED BY 2. TABLE BASED 04 AXom jy0RK11+IG LOAD OF %1501 ADD DA)ONAL TIE TO OPPOSTE BEAU e ^ . ' , 'f • • M'^a\rIj/25,2008 INYV. A MAIL EAVE OyERHANC REFERS TO OVERHANG AT S0E*AII NOT FRONT OR REAR � � y��( ."' ' > �,1��.. FEDEwu raxUFACNRED HOME CDNSfR0CD0N MD5AFETYSLDiDMDS 4, AB TABLES APPLY Tom' me AND 184' FLOOR tOTHS TH 96 1/Y' SPAOK IOW WAQL] SDE*ALL HEIGNT ANO Ir SIDE ;Y- /rr� s «J '• - OVERHANG (6' OVERHANG VAx EACH 9DE OF Will �o rS���`11'•.� f rHwUP �ht�• s STA%aR PLATES ARC REOUIRED ON 9DE*ALL ANGM AND LONOT04AL A10M SET IN FLORIDA. SEE DIjV ROLE IK EFFECTIVE VARDL 2% 1999. �I HS'' i ••' �` fi r,, iT�10) JACOWEN HOME,O tiORdd� um �LF�� At_'CUB �f�!AL• tHk AI{uFACL1l�1G OA c o.I�.T. DATE; 1z-it-o7 REV. LETIM DRA SIG 711M IJA1FAAt5uLi aAmesEp NORV. SPACING TABLES P.O.MWEI Box 368 SAFETY E(f95� PHONE (7 72138 91Po Aluad ARE PROM bAAq OR G AD-TO-0087 6U . ADDENDUM SHEARWALL TIE-DOWN/PIER REQUIREMENTS car. SA Lo m _ , , fff." WO FU SHEARNW (ALL siuhlwrrS} 11%OoMwrS Itt]p�itD aaa va 1R KaaWm -` iM NOTE r ut NOTE IZ� �� . 3EE MOTES 2 MID 3. Z__] ► at iMQb m READ TITS Lo[AT10H IRS LO ATIOH FIGURE 8, 0 . FIGURE 8.1 THE DETAIL A13OW IS SHOWN WITH A TWO PIER SHEARWALL CONFIGURATION, HOWEYER, THIS DETAIL APPLIES TO All SHEARWALL CONFIGURATIONS, ALL ZONES. •AND ALL --IF VALUES. crr. S/M uum m.oR M t OI so" 1 ~ W-C 14XWMW W-V AM X-WW TtWw NAT ti LWAIM UI um Of m AK" Dow AM Olm Famm AT 10 onam AraQts W w mim ITM m UCWit LOAD BUmso taffl LaAot= W-R}-M (fD-OW RAL NOMI nR WM Qf Ot M llaT1111rat) WWU A MAT Got DO Cr TMC sTAMWL nMs (rot UC AMW DtTArL7� IM MgMM AT LOCH 00 CO JdSTS REQ UILSS or W-ova1 "W hCcu�gKri) W01 SF[M1WL IS LOCATED ABotit A 3AD ffJbETI ttltt K afT QMes-MWA no K-WW 3i An Ot AM ARE R(aXU (XL WANU mW10;A WK1 All UMS Am Ail. KraW 4 I T110 PH sffEaNlll us 1 'B A 1 1 Om I Lp OR gE HOTC 1 S£E NOTE 1 A SEE RM i AND I A IRS L%ATmK TIOS I,thil- u-i ' 910334 1 i STATF— (W ROVED BY iEB 10 2W ANC. MANUFACTURED HOME CTION AND SAFETY STANDARDS JA013SEN HOMES wocwcowma '`}� •`•'.R. oz 1-00 auoxg. faro �1Rr, A+tt .. P.a. eox Elsa ramaac at �ooe�ot r�a� 5/WIU TIE/PIER REQ. WETT NARGO& FLORIOA 31595 t1C 6LfCii YATO�Af! AttL v 1ua�an raw ttpr� rwaRs w .r u rC f�iTAwMG rwl3tx: . PHa+E ( 720-1138 f dr aoRpUt+t Mo ATrr�cr rRau ena�c - A0—ib-100 61 ADDENDUM DOUBLE SHEARWALL CONFIGURATION SINGLE -SECTION TIE -DOWNS / CE ING MAY BE FLAT OR SLOPED NOTES: z/7X I. CT40UND moms TO BE RAim FOR AH u1111ATE LOAD OF 47251 [3150 DESIGN LOAD] (SEE AD-TD-O..-D1 17D-f FWM Homs) FOR NOTES ON CNOUN) Mr.40R KSTALIAl10N.) 2 KSTAlL A PER AT EACH ENO OF THE %onALL JOISTS (PER THE ABOVE DETAILS). 3. WEN SI,FARYM& IS LOCATED ABOVE A SCUD IEADER (iU.L KOFF CROSS-YEU9FP.) NO TIE-M,-4 STRAPS. OR PIERS ARE RE=M (ALL SHEARWALL CCNFICJRATIONS, ALL ZONES AND ALL EXF'MM). 4. TE-DO1W4 STRAP REQUIRED AT EACH END OF JDTSTS, ALL DB: PW CONFIOJRATIONS. S. CEILNG SHOW`T FLAT -OPT,CATHEDRAL OR SLOPED CEUHG MAY BE USFD. i G. FULL WIDTH SHEARWALL`S ARE SHOFRT IN 7HE DE7AL•ABOVL HOWEVER. ANY LENGTH OR CCNFTGURATION SHEARWALL MAY BE USED. END VIEW 350 PLF MAXU)M SHEARWALL DES.V,N VALUE (PER WALL) 1 1/4' X .035' Tf--^OVM STRAP CONT14UCJS ARCJ.ND JOISTS. .. � tP�f1OVAL • ,7 �y •� . •. ,��� czr DE VIEW X .OW 11E—DONN STRAP UOUS ARI MD JOISTS. DAPIA APPROVAL• [APPROVED BY .� lN*ff i; N LETrER- JACOBSEN HOMES THEM SPEOFIC n°NIAw DRAWNCS #RE DRAAH BY: R R DATE• 2-6-96 REV.' 0RK7EAL, P010PRRiA4Y, A. -AD MCM!NTIAL DRAVANG TITLE: j P.O. BOX 365 MATER.ALS OF JACOBS9N MANUFACTURIC DBL. S W CONFIG. -BE-DOWN SAFETY HARBOR. FLORIDA 34695 REOMMI FOUR S'E M F1 �s IND U 1 FE DRAV«NG NUUBER: PHONE (813) 726-1138 KEPT CONFTOEOX ND S?:UiET TIM DR1ER5. AD-TO-0110 J 62 DOUBLE SHEARWALL CONFIGURATION TRIPLE & MULTI SECTIONS CEILING MAY BE FLAT OR'. SIDE VIEW SIDE VIEW (MARRIAGE WALL APPLICATION) (SIDEWALL APPLICATION) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4' X .035' TIE -DOWN STRAP CON71NUWS AROUND JOISTS. TO 35' I. ORWNDF ANCHORS 10 BE RATED FER AN ULTWATE LOAD OF 4725/ [3150 DESIGN LOAD] (SEE AD-YD-0001 [TD-GENERAL NOTES] FOR NOTES ON GROUND ANCHOR INSTALLATION.) 2. INSTALL A PER AT EACH END OF THE SHEARWALL JOISTS (PER THE ABOW DETAILS). 3. WHEN 9iARWAIL IS LOCATED ADOVE A SOLID HEADER (FULL HEIGHT CROSS -MEMBER) NO L TIE-DOM STRAPS OR PIERS ARE REWIRED (ALL SHEARWALL CONFTWRAMONS, ALL ZONES AID ALL EXPOSURES1 4. TIE—DOAN STRAP REOUIRED AT EACH END OF JOISTS. ALL DBL S/W CONFIGURATIONS 5. CEILING SHOWN CATHEDRAL OR SLOPED, FLAT CEILING MAY BE USED. 6. FULL WIDTH SHEARWAILS ARE SHOWN IN THE DETAIL ABOVE, HOWEVER, ANY LENGTH OR CONFIGURATION SHEARWALL WAY BE USED. 7. THIS DETA.1 MAY APPLY TO TRIPLE AND/OR DOUBLE WIDE SECTIONS. 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4' X .035' TIE —DOWN STRAP CONTINUOUS AROUND JOISTS. John C.-Doedenjl. 15133 C. R. 22 Goshen, IN 46526 I4 IS A TRIPLE WIDE RAFTER, 1 APPLICABLE TO STANDARD 31.E WIDE TRUSSES. JD VIEW X .OW TIE —DOWN STRAP JOUS AROUND JOISTS. NOTE: ALSO APPLICABLE TO 'SUP SSE' MARRIAGE WALLS WHEN AT LEAST 2 STANDARD VERTICAL TIES ARE INSTALLED, (1 EACH SIDE ADJACENT TO SHEARWALL LOCATION) APPROVED BY 1 W61RA.11PIAiOW �f A►06 m JACOBSEN HOMES BOX 368 THESESPEOMAIMSA ORAw= RE ORONAL. PROPRIETARY, AND CO1dIDEN11AL MATERIALS OF JACOBSEN MAIUFACTURINc� SUCH OUAWNBY: RR DAIEc 4-09-96 IREV LEER nP.O. DRAWING S/W CONFIG. TIE—/Lj` SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 ARE PROvIoM H �T K REOMT FOR SPE�au AND IVT MWIDD DRAWING NUMBER: IDAL AID SECRET IROu popes AD—TD-0)1) 63 PORCH ANCHORING DOUBLE HEADED 3,11• NOTES: 1. SE SET-UP MANUAL AND ADDENDUM FOR APPLICABLE BLOCKING X .035" TIE -DOWN STRAP JOUS AROUND STRAP 'BLOCKS. MNDZONE III EXPOSURE C (110 MPH) 20 PSF ROOF thr 10 PSF O.L "iCALCS.'. c ;vA 409 10 1 09; W-1; 7 J: DAPIA APPROVAL: PPROVEDBY 114INC. EDERAL MANUFACTURED HOME NSTRUCTIDIN AND SAFETY STANDARDS Mr J;i .4 M. NOTICE: DRAYM BY: OATS: REV. LETTER: JACOBSEN HOMES lKSE SpECFr_A=* AND DRAWNGS ARE M. T. 12-13-03 MCINAL, PROWTANY. AND CWMnk DRAVANG 71U: mATmALS oF PDMSDI mMwAC7'mc PORCH ANCHORING P.O. BOX 368 PC SUM MATMALS ARE PRMM 10 7K SAFETY HARBOR. FLORIDA 34695 WW FM SPEOFE RWM NO 116T BE DRAWING WIJBER: PHONE (727) 726-1138 KM CWMMK AM SFIFT MW OUM AD-TD-0112 64_ ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION FLOOR DIAGONAL FRAME TIE I —I I ANCHORING EQUIPMENT CAPABLE OF RESISTING -I I I — THE WORKING LOAD REOUIRED ON THE —I TIE -DOWN SPACING TABLES (SET_ OTHER DETAILS FOR TABLES) SEE OTHER DETAILS FOR ANCHOR ANGLE. NOTES: APPROVED VERTICAL TIE -DI (FACTORY INSTALLED) ' CRIMP SEAL (3150/ WORKING LOAD) )WN ANCHOR BRACKET ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91. vv STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. RADIUS CLIP ac 3 9 VERTICAL ME -DOWN c TYPE I. FINISH B. W GRADE 1 STEEL STRAPPING 1 1/4' WIDE k 0.035' IN THICKNESS, CERTIFIED BY to A REGISTERED PROFESSIONAL ix 1. ALL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPI BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RADIUS CUP MUST BE INSTALLED ON ALL TIE -DOWN ANCHOR BRACKETS. (INSTALLER TO FAWCATE RADIUS CLIP BY PLACING A STRAIGHT 3' LENGTH OF 1 1/4' X 0.035' TIE -DOWN STRAP MATERIAL IN ANCHOR SLOT AND BENDING TO FORM THE affIGURATION SHOWN.) RADIUS CUP MUST BE INSTALLED TO PROTECT THE PE -DOWN STRAP FROM THE BRACKET EDGES. INSTALL THE 71E-DOWN STRAP THROUGH THE SLOT IN THE BRACKET 'QLMLLr THE RADIUS CUP. ``��11111111I1111�Y�Y�' %�'�NC. %STF pF�F �'AkIROWANo. ENE0703571_ TA z"",, /OIAL E�., ANCHOR BR jtiIII,1AG TIE -DOWN DEVICES ARE CERTFED BY OTHERS NOTICE TKSE SPEO►ICAT04 AND DRAMNGS ARE Of0MN PROMETMY, AND CC ffMTPL YATERALS OF JAMM MAP"ACAM MC m YAWmS ARE PRONDED TO THE 107 Cdf Rk AND SECRET IRW OMM DRAWN BY: DAPIA PROVED BY JW 1 5 ON YtDEAr IMgfACi{ImNii 14INC WaALRimiallMt1YAA1om C.L.Y. 1 5-31-95 oRAwwc 'Rot-ALT. TIE -DOWN APPL. AD-TD-0200 im 65 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION APPROVED VERTICAL TIE=DOWN ANCHOR STRAP (FACTORY INSTALLED) FLOOR IF FACTORY INSTALLED STRAP IS NOT LONG ENOUCH•- IT YAY BE LENGTHENED BY USING A CRMP SEAL W17H A WORKING LOAD OF 3150 POUNDS !10 0 IF NEEDED, USE VERTICAL �f TIE -DOWN TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING ry 1 1/4- WIDE k 0.035- l� f IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS DIACONAL FRAME TIE CONFORMING WITH ASTM STANDARD O SPECIFICATION D3953-91• O STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. II III I 1III 1(- ANCHORING EOUIPMENT —III III —III -I I CAPABLE OF RESISTINGTHE WORKING LOAD _ REQUIRED ON THE —III -I I TIE -DOWN SPACING _ TABLES (SEE OTHER I I I -I I (- DETAILS FOR TABLES) SEE OTHER DETAILS III —III —III -I FOR ANCHOR ANCLE. ON TES: 1. ANY ADDITIONAL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). JACOBSEN HOMES THESE SPEaII natTs AND D AM ® CRIONAL. PROPRIETARY. AND WITIDENTIAL P.O. BOX 36B MATERIALS OF JACOBSEN YUTACTLIRDIC ❑�� Imo. SUat MATERIALS ARE PRONDED TO IHE SAFETY HARBOR. FLORIDA 34695 REaao+T rat SPEa1C PURP m Al® Inns K N❑ PHONE (013) 726-1138 IVT CDOWTIAL NO SECRET MOM OTHERS DAPIA APPROVED BY REVISED 1012319E ON INC. r aTFU TM AND( O YSI r>rxsmlcTnN AND sAcnr FrwoU+os DATE. REV. LEM R.R. 1 70-05-96 ALT. TIE -DOWN APPL. AD-TD-0210 J 66 ADDENDUM COLUMN TIE- DOWN APPLICATION ANCHORING EOUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. 0 ANGLE SHOWN. FLOOR =�TTT=IT I�rl � ANIi.E I I III -I 1I- II-,Ili ANCHORS INSTALLED 24" APART COLUMN STRAPS SEPERATE GROUND NOTES: 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES. MARRIAGE LINE OF MULn-WIDE ATTACHED ANCHORS VERTICAL TIE -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4' WIDE k 0.035' IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-9T. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL, AND SEALS. 35' ANGLE TO TWO (3150# EA.) ENE8703571 %�aIA�F Lps�o�JAt E AFr .-:, �,7 , ED 8Y f AN 1 5 ,-Nlr[ teu[ rw,r•cnmbw INC, D]4iR;ICIO1AwiME1Ti aim JACOBSEN HOMES THESE SPI[anCATM AND DUTIPM ARE TCaETS1:N VA"ACIMMC IMAWNOrC.L.Y. """ 5-31-95MWAL A DRAWING TITLE:- COL. T1E-DOWN APPL.Nc P.O. BOX 368 ,I 901 MATTIEPTS ARE PRONGEDTO THE SAFETY HARBOR. FLORIDA 34695 SAFETY REDPEENT rCA WE= R13 M ADO RM K DRAWING NUMBER: PHONE (813) 726-1138 IVT CGI WTA NO SEOILT "= OMM AO- TU-0251 66 ADDENDUM COLUMN TIE -DOWN APPLICATION It a � ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / WN. COLUMN STRAPS SINGLE GROUND NOTES: I. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. JACOBSEN HOMES P.O. Box 368 SAFETY HARBOR. FLORIDA 34695 LLLJU PHONE (813) 726-1138 MARRIAGE LINE OF MUUI-NDE Fll1KKfl VER71CAL 71E-DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING. 1 1/4' WIDE & 0.035' IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTIR STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. y ATTACHED TO A ANCHOR (3150#) .."willifill _ 5O Q'` No. RFo ci .� F�NE87�3�}- g %,'!OVAL Eye NOnCE TNESY SPE011G1TION5 AIO WAMI115 Alm 0a0N8L. PROPIIETAI114 no OOWIOOITNL MAmpa AF 11COBSTw ""MUM W. SM VAMNS ARE PROMM TO IC RE04111 FO1 SRCM FUWM AO MAT BE AB'10iFWR4 AN1 SLOV IR01 MM BY: APPROVAL - PR BY) JM 1 541 1995 INC C.L.Y. I ------ 5-25-95 COL TIE -DOWN APPL. It AD-TD-0252 r%Q ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EOLIIPMENT, CAPABLE OF RESISTING THE WORKING LOAD OF 4000 / MIN. COLUMN STRAPS SINGLE GROUND NOTES: 1. ALL ANCHORING EOUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. MARRIAGE LINE OF MULTI -WIDE FLOOR VERTICAL ME -DOWN TYPE 1. FINISH B, GRADE 1 STEEL STRAPPING 1 1/4- WADE & 0.035- IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTIR STANDARD SPECIFICATION D3953-91, STANDARD SPEGFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. ATTACHED TO A ANCHOR (4000#) . _ still,ull,.. ���• G%ST E�* * -. No. FD r BYE, I .o 1 5 10 IV 11'1 INC. W R1RICiOI MO SARI: T9iOIIR H09TCEk 4 lWAWM+BV. DALE Mv. LLI IU : ESE JACOBSEN HOMES 1HSKC�TM AM DUWM AKC.L.Y.5-25-95 CWaHAL PRWMAff. AHO CMRMTUL DRAWNG ME' MATDTIAS CF JM=S I MAMIFACTdUC COL. TIE -DOWN APPL. P.O. BOX 368 W_ SM MATERIALS ARE PRONGED TO THE SAFETY E13261695 DRAMtNG MIMBER PHONE 726--138 Cdtuq N0ogmnoo� AD—TD-0253 7n ADDENDUM TYPICAL SINGLE WIDE TIE -DOWN PLACEMENT SEE NOTE 2 A B C 24' LARGE OPENING 24' SEE NOTE 1 dIMYMV �N�IIMY ILL -WILL\ ., Ilw ., M BRACKETS (SEE TIE -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXIMUM SPACING ALLOWED). ALSO SEE NOTE I STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INST90 A MAXIMUM OF 2'-0' (241 FROM EACH END OF THE UNIT. `�1\111IIIIIIIrrrr// C• Doe '% NOTES: ENE8703571 DAPIA APPROVAL: 1. LARGE OPENING = ANY OPENING HIDER THAN MAX TIE -DOWN SPACING ALLOHED._ �.� - ROVED BY 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL T&DOBN SPAa , - 14•Ir- SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ) DOES NOT EXCEED THE TIE SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME 5 1 MAXIMUM -DOWN ,�'••//� >�'��� ��'ii��t%+'• TIE-DOAN SPACING TABLES (SEE OTHER DETAILS). • Nv\`�` INC 3. INSTALL FRAME TIES AT ALL VERTICAL TIE-DOIN LOCATIONS. ��i� rlI'll AL ��``� __ . _•-�wlniolc 4. SEE AD-TD-DOO1 FOR ADDITIONAL REOU>REMENTS. ANCHCtt BRACKET AND TIE-DOPM DEVICES ARE CERTIFIED BY OTHERS JACOBSEN HOMES NOTICE THESE sKN�TKM NO DRAB CRIaNAI. PROPRIUMT. AHD CCNUNT l DRAWN BY. DATE C.L.Y. 5-31-95 REV. LEM- %` DRAIANG TITLE: T/D MATERIALS CF OZ08SEN MNaN ANUiACT"G TYP. SINGLE WIDE /-1 P.O. Box 368 nc swit= LS AM maw 10 TIRE DRAMWG NUMBER AD-TD-0300 SAFEP ONE (0 R3) FLORIDA 384695 �my CGNFD�0I�me =w no � 72 ADDENDUM TYPICAL MULTI- WIDE TIE -DOWN PLACEMENT SEE NOTE 2. A B C 24' LARGE OPENING SEE NONE 1 COLUMN SUPPORT TIE-DOVM STRAPS. REQUIRED AT COLUMN LOCATIONS ON EACH SIDE OF OPENINGS GREATER MAN 48' IN WlOTK MULII-WIDE FLOOR SNOWN SEPERAIED FOR CLARITY 24' 24' v V 24' ' LSTANDARD VERTICAL TIE -DOWN SIM OR ANCHOR BRACKETS (SEE TIE -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAKIM SPACING ALLOWED). ALSO SEE NOTE 1 STANDARD VERTICAL TIE -DOWN STRAPS OR ANDNOR BRACKETS TO BE INSTALLED A MAXIMUM OF 2'-0' (241 FOR TRIPLE WIDE AND LARGER UNIT DESIGNS, INSTAL 01111111110E 7 � EACH END OF THE UNIT. ALL TIE -DOWN STRAPS AS SHOWN IN THIS DETAIL .���N C• DpF'''i,,�� NOTES: v ••.? '� DAPIA APPROVAL - I. N0. O 1. URGE OPENING =ANY MNG WIDER MAN MAX TIE -DOWN SPACING ALLOWED. ' • NE8703571 OVED BY 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TIE -DOWN SPAR , SO LONG AS, THE AVERAGE SPACING ( (A+B+C) / 3 ) DOES NOT EXCEED THE 4L�.,r•� ' MAXIMUM RE -DOWN SPACING REOUIRED ON TIE APPROPRIATE VERTICAL/FRAME T6 OF 1 TIE -DOWN SPACING TABLES (SEE OW DETAILS). -�` • fti .. 5 10 '4' ��• n� 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DOWN LOCATIONS. �o • .. A •���`�` I I V 4. SEE AD-ID-0001 FOR ADDITIONAL ION REQUIREMENTS. ANi4(T eg ItA11J TIE -DOWN NOfN"T191OY°� DEVICES ARE CfR11F1ED BY 07HERS NOTICE DRAWN BY. DATE REV. LETTER: JACOBSEN HOMES KSE sKonu1uts nDNs AND DrNARE C.L.Y. 5-1-95 MOINAL PRO MUMT, AND CMUNT1AL DRAWING DTTE: A P.O. BOX 368 MAMAL.i OF JACOBSEN MANVACIIAM DR MULTI —WIDE T/D „ SAFETY HARBOR, FLORIDA 3/695 1I�T FQt � FJFM AND MAi K DRAWING NUUBER PHONE (813) 726-1138 im cmm noL AND sou n= ormm AD—TD-0310 73 ZONE I TIE -DOWNS MARRIAGE WALL I OPENING TIE —DOWN I (REQUIRED AT OPENINGS ONLY. OPTIONAL AT SEE DETAIL - 'A' OTHER LOCATIONS.) FRAME TIE -DOWN' SEE DETAIL - V _ SINGLE WIDE TIE -DOWN NOTE` C SECTION MARRIAGE WALL - SIMILAR TO I OPENING TIE -DOWN SINGLE WIDE (REQUIRED AT OPENINI FRAME TIE -DOWN ONLY. OPTIONAL AT OTHER LOCATIONS.) PULL DOYN TIGHT TO --/ GROUND ANCHOR DETAIL 'A' DOUBLE WIDE TIE -DOWN I NOTE: A k B SECTIONS SIMILAR TO DOUBLE IWIDE TIE -DOWN TRIPLE WIDE TIE -DOWN SEE DETAIL — 'A' SEE DETAIL — V TIE -DOWN STRAP SINGLE HEADED GROUND. ANCHOR (WHEN MARRIAGE WALL TIES AND FRAME TES ARE LOCATED AND SECURED TO THE SAME GROUND' ANCHOR, A DOUBLE HEADED GROUND ANCHOR MUST BE USED) BUCKLE PATH 20251 ALL GROUND ANCHORS MUST BE LISTED TO CARRY THE LOADING FY MINIMUM IMPOSED BY THE TIE -DOWN STRAPPING (3150 LBS. MAXMUM FOR EACH TIE -DOWN STRAP CONNECTED). DETAIL 'B' TYPICAL TE-DOWN STRAP (1 1/4' X .035' MINIMUM ZINK COATED STEEL STRAP, OR EQUAL WITH 315o4 CAPACITY MINIMUM) >c 1,5a 471,S « ULTjftv4 Lr Loco a4gacrfy 19 Lnw�r� �wi NOTES: �. .�...... 1. SEE DETAIL 'B' PAGE Q AOR MARRIAGE WALL q�y OPENINGS GREATER THAN 49 INCHES. & UP TT� o I'T�-6" I B T Piyt, 0"11354S4 2. SEE TIE -DOWN SPACING CHART ON PAGE 2 EDR ANCHOR AND TIE -DOWN PLACEMENT. 3. SEE DETAIL 'A' PAGE FOR TYPICAL I -BEAM STATE OF PIER CONSTRUCTION. '•.. t0n0 P APPROVED BY p�C 2 INC �-n�cnwo a�vcY'�ssHoyas NOTICP_ BY: RR TDAIE. 10-31-95 REV. LETTER: JACOBSEN HOMES »SSE sPEonca m AND DRwNNIZ AFIE OMONAL. PROPRIETARY. AND CONf10 UIL DRAMING TITLE LATERIALS OF JACOMEN MANUFACTURING ZONE I TIE -DOWNS P.O. BOX 368 W. 9XH WMERIALS ARE PROVIDED To THE SAFETY PHONE (813) 7206- 1384695 W7 C rMMNO SEOV O ODIUM f DRAWWG NUMBER AD—Zl —0001 74 ZONE I TIE -DOWN PLACEMENT TYPICAL I -BEAM 1TE-DOWN MAIN FRAME I -BEAM - -NOTE j1� - MAIN FRAME I -BEAM IEND AACINGI SPACING CENTER I SPACING CENTER I SPACING CENTER I SPACING CENTER I SPACING _ END I SPACICI DOUBLE WIDE TIE -DOWN PLACEMENT END CENTER CENTER CENTER CENTER CENTER END arnunu xnu,w xn.w,.v TYPICAL I -BEAM TIE -DOWN MAIN FRAME I -BEAM SEE NOTE 011 NOTE j11 MAIN FRAME I -BEAM MAIN FRAME I -BEAM SPAR cENT END CCMGI SPACICENNG I SPACING L&.ACWGI TRIPLE WIDE TIE -DOWN PLACEMENT NOTES: ENaNEER♦� DOc T. SEE DETAIL 'B' PACE 4 FOR BLOCKING AND ANCHORING OF +♦♦♦��G����FIQ;9r�Cy MARRIAGE WALL OPENINGS WADER THAN 49 INCHES. N0.01745484 {° 'STATE OF JF i ce co Ell DAPIA APPROVED BY II V iFCEMI Y4�f4C'MED M3Q coaTRucicN Ago svrn awawab NOTICE rwymon- RR 10-31-95 — — -- HEADJ AC O B S E N HOMES TNESE SPEonca NS AND DRAWINGS ARE ORIGINAL, PROPRIETARY. AND COEDWTIAL DRAWWG TITLE: UATERIMS OF JACWSIT MANUFACTURING TIE —DOWN PLACEMENT P.O. BOX 368 WC. SUGI YAMULS ARE FRONDED TO THE SAFETY HONER(813) FLORIDA26384695 BUT CtT�FMOB SPEOf1C PUiPO TK NO SEW n= ONTM DRAWWG NUMBER- —Z1-0020 I 76 ZONE 1 INSTALLATIONS 1. FOR HOMES LOCATED IN ZONE I, FOLLOW THE MANUFACTURER'S ZONE 2 INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF LONGITUDINAL ANCHORS. 2. FOR HOMES LOCATED IN ZONE I ONLY, FOLLOW THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF SHINGLES AND/OR LAP SIDING. FOR ALL OTHER WIND ZONES REFER TO DETAILS IN THE SET—UP MANUAL AND/OR THIS ADDENDUM. AP ROVED BY lz Cd. FEB 0 1 M INC JACOBSEN HOME NOTICR V^^ym •• insc s wnUnOKS AND ORA"= ui6 M.T. 2-1-00 ORCHA1. ►RMK701. µD COF M1AL DRAWING TITLE: A P.O. BOX 36H °"MAsCr4%C UVARE UAMNACMIMC ZONE 1 INST. SAFETY HARBOR. FLORIDA 34695 fat 99 M APWIM mist u DRAWING NUMBER: PHONE (727) 726-1138 KPI MICO ud wo stoic* neat DDos - AD- Z1-0100 77 ADDENDUM FOR INTERSECTING UNITS MAW UNIT DORMER TRIPLE WIDE OR QUAD WIDE I SECTIONS) bl 3 L _FI MAXIMUM PIER HEIGHT FOR VARIOUS ZONES (REFIER ALSO TO SIDEWALL TIE-DOVNS MAXIMUM HEIGHT} zff-z low EXPOSURE V 90' 56' EXPOSURE '0' 39' 46' LONGITUDINAL TIES ONLY REQUIRED 0 EA. HALF OUTSIDE BEAM IRIS END, EXCEPT FOR 20NE 3 EXP. V THEN 2 REQUIRED EA HALF (IE CNE EA. BEAM, ETC-) VERTICAL AND DIAGONAL TIES INSTALLED ALONG THE SDEWALLS SAME AS THE MAN UNIT. VERTICAL TIES AT CENTER LINE REQUIRED ONLY AT COLUMN SUPPORTS PER DOUBLE MOE CONNECTION REOUIREMENTS. 24' MAXIMUM SPACING TO FIRST SIDWALL TIE FROM EACH END OF THE UNIT (SAME AS TYP. DOUBLE WIDE TIE -DOWN REOUIREYENTS). 2 L040TUDINAL TIES REQUIRED AT EACH HALF THIS END ONLY. CONNECT THE TRIPLE WIDE OR QUAD. WIDE SECTTON(S) TO THE DORMER AND MAIN UNIT PER DOUBLE WIDE MARRIAGE LINE DETAILS AS OUTLINED IN THE SET-UP MANUAL (EXCEPTION: NAILING ONLY IS REQUIRED AT FLOOR CONNECTION. NO STRAPS ARE REQUIRED TO BE INSTALLED ACROSS THE FLOOR CONNECTION AT THIS AREA.) `````U1111111111►//�//J�i NOTES:EN RDV �i DAPIA APPROVAL`����>O•..��\SA%ER�.F,1,'-,; 1. FOR WAD SECTIONS• EACH DOUBLE SECTION' OF THE UNIT SHALL BE DESIGNED Q' NO O y APPROVED BY A INDEPENDENT OF THE 01HER STRUCTURE (IL SHEARWALLS, TIE-DDWNS, RIDGE- EN 0357 � �` "" BEAMS, COLUMN SUPPORTS, ETC... ARE CALCULATED FOR EACH MULTI -SECTION.) AN 1 5 M5 INC,S A "'- .e�''• �^��'� r.�:•' � � claw wm/.c7wtD wE %�,A.• V� �.�' nm�e,no�nowmsuictiso s!onraLll %,%% ' JACOBSEN HOMES NOTICE-- DRAWN BY: DAIS REv LEA: THESE SPEQI1CA710115 AND DRAMNts ARE C.L.Y. 5-16-95 OMONAL PROPRIETARY; AND CONIiCOI'm DRAWING TITLE: P.O. BOX 368 MATEMALS OF JACOBSEN MAUFACTURING ADDENDUM —INT. UNITS PROK0 TO SAFETY HARBOR, FLORIDA 34695 EaIm IN SCFX R�KSES kO W5T� RroP BE PHONE (813) 726-1138 01 COIOI7E Ak NO SECRET TROY OTHM DRAWING NUMBER QUADADDI 78 ALT. ROOF ASSEMBLY FOR MULTI- WIDES CENTERLINE CONNECTION FOR QUAD UNITS IS THE SANE AS FOR THE RAIN UNIT (REFER TO SET-UP DE1AH14 NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE MIND DEFLECTORS REMOVED FROM ROOF IN ORIAAL CONDITION (EXCEPT FOR STAPLE HOLES). STEEL STRIP MAY BE CONTNUOUS OR PIECED. 2. SHNGLES N THE DORMER AREA OF THE MAIN UNIT MAY BE SWPPED LOOSE AND INSTALLED ON SITE AFTER THE UNITS HAVE BEEN ATTACHED TO PREVENT ANY TRANSIT DAMAGE AND TO ENSURE THE SNINGLES UNE-UP FROM ONE SECTION TO THE NEXT. 30 GA. GALV STEEL STRIP INSTALLED OVER RATING LINE JOINT (SEE PLAN NEW BELOW) ROOF PERDNETER RAL OR ROM BEAR CROSS-SECTION 30 GA. GALV. STEEL STRIP 8' X LENGTH OF ROOF SSECTIONS RAY BE OVERLAPPED 2 1@L.) W/STAPLES AS SHONR. INSTIL. ROOF CAP PER SET- UP RAN. OVER GALV. STRIP. (SEE NOTE 1) 30 CA. CALV. STEEL STRIP SECURED MATH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING 2 - O.C. RAIL SPACING (TYP.) G1STf9 ��F Q No. ENE8703571 Fs ��i9q� 3/8' X 5' LAG SCREWS 11 '(ZONES 2 k 3) STAGGERED �D 8Y E'er" aw 1 5 m 1111l INC as AV LAI ai vom NOTICE: -11111 IDfi1NFHT: DATE: REV. LETTER: a JACOBSEN HOMES THESE SKOnCAIM AND DRAVINM Ark C.L.Y. 5-16-95 oraDNAI,PROPRIETARY.ANDCDHFMTIAL DRAWING TITLE:P.O. BOX 368 MATEAINS OF dACOM W MNACrANC ALT. RUOF ASSEMBLY Nc 20 MAMU S ARE PRNM TO THESAFETY HARBORFLORIDA 34695 RECPOIT Fa SP[Cfl<PJFMS NO VM K DRAWING NUMBER: PHONE (813) 726-1138 Tarr ODFMDAL NO Nov ►ROM orsm QUADADD2 79