SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributorsand shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
FILE COPY
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/09/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
QOTRINITYIERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:'
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Entity
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-112453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme® are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Devonshire"" are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration®, TruDefinition® Duration®, Duration® Premium Cool, TruDefinition® Duration® Designer Color
Collection, TruDefinition® Oakridge®, Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip & Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgeT1 Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8
Certificate ofAuthoriration N9503 61
" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 2 of 8
Y
Q0TP,,,,1N1TYjERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with .FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (Vnit = 194 mph). Refer to Section 6 for installation
requirements to meet this wind,rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all -wind zones up to Vasd =150 mph (Veit = 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations.. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 -All products in the roof assembly shall have -quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6_1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 611320-3, per FBC 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatheeGuardo HP shingles require minimum six (6) nails per shingle.
➢ Devonshire"" shingles require minimum six (6) nails per shinglye.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be,in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck
Self -adhered
WeatherLock•
' underlayment
odDrip edge
9 . "
n'
Nails located
2"-3" from eave
Install first Self-sealing adhesive
Starter Strip positioned along cave
shingle with \
6' removed
Starter Strip shingle overhangs eaves and rakes'/i'-s4
Exterior Research and Design, U.C.
Certificate of Authorization #9503
Fetrunderlayment Deck Self -adhered
weatherl ock®
undedaymorn
Drip edge
Drip
edge
Nails located
2"-3' from cave
Insist! firstStarter Strip Plus SerlfseaG adhesive
with 6" removed Porrcd along cave
StarterStrrp Plus overhangs eaves and rakes 1/4-V4"
0' EDITION (2017) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
Evaluation Report 037940.02.12-118
FL10674-R13
Revision 8:10/09/2017
Page 3 of 8
6.2.6 Minimum Nailing —Classic® & Supreme:
6,
Normal Mansard or Ana paw
Wind,Ar"W. High Wind dosvanas,y
A►sai,piin dontoi ninnims Areas vientoi fdaFNs
(A),
Eiipoauie
Espo�ieJ6n
2.7 Minimum Nailing— Berkshire®:
Standard
ng Pattern
r
I
QOTPJNITYIERD,
Normal Mansard or Ar- pm
WindArasp • High Wind das0ans's,►�
Area pins vlentoi normales Areas' vlsntoa'fairbs
f'- r 2•.
5 6/8',Exposure
Erposlil6n
Ssalarrt strip
Ls tire de selladoi
T.
r
r
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
6-Nail Fastening Pattern
Evaluation Report 037940.02.12-R8
F1.10674-1113
Revision 8:10/09/2017
Page 4 of 8
6.2.8 Minimum Nailing- Devonshire'":
1" 7" 1 8" 1 8" 1 8.1- 7' «1"
`• aawn
53l8° exposure Sealant location
Exposicl6n de 5 ^5!8 pulg Ublcaci6n del sellador
Standard 6-Nail Fastening Pattern
VNTINITYJ ERD
Nails
r r c 7 r
sn• �•
Ten V Spots of Asphalt Roof Cement
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
4-Hall Fastening.Pattem
', sluaNallID tKbriiny'ani wtEN
Nap. TA"M
(Om-
a=
Standard Fastening Pattern
"all Fastening Pattern
sure"""," w dzN
Nau.?YW�
1 12^' 12"F] �7 F1 -j
T
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, I.I.C.
Certificate ofAuthorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
6-Nail Fastening Pattern
Evaluation Report 037940.02.12-118
F1.10674-1113
Revision 8:10/09/2017
Page 5 of 8
6.2.1 Minimum Nailing — TrulDefinitione Oakridge", OakridgeO:
4wal(paftsm
4sc* Fa condavos.
Standard Faste
ittern
QI RIMTY I ERD
6-Nall Fastening Pattern
Fastening (or SlopesGreater Than 21:12.
W14"" W3 WWth
M14 Typial
ij 12" ir r
,.,.Spots ofAspUn Rwfing C—t
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing — WeatherGuard® HIP:
Exterior Research and Design, H.C.
Certificate of Authorization #9503
1i;0_2V
Evaluation Report 037940.02.12-R8
CH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 6 of 8
ti
QOTRINITYIERD
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, WeatherGuard® HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgelrl Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire" Hip & Ridge and High Ridge:
I
<— ,Pnvdlmg Wnd
Dsedlan r
Fig. 2
rogVley,;
swewew
_ Nails
�� 7 inP L3ntldaled r` ll
4--
Piece
�.• �:,, .
r
I.
I
0"
gl
I.
I
I
I.
6.3.4 Minimum Nailing — WeatherGuard° HP Hip and Ridge:
Fig. A v. v
PrOWtlNg YP,aW
'E—Dlreelbn- - A� -
p '.
1 1
' 1 I
r I
AA 1 L,
Exposure
Fig. C Hip &,-Ridge;Shifigle Fastening'
ToPVlew
I
Nails. Nails
5. Erzposure
I' 77
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-118
Certificate afAuthorization #9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction SOa hm strip
8" EKlic ure
Co"' Faposod
Futenne with
Roof Cement
de
TRINITY I ER®
Standard-1f■_�
Fastoning
Pattern
$omint
71h�
8" Fxpoaure
I•
12°—►�
6.3.6 Minimum Nailing — Duralkidgelm Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning,
published installation instructions for their minimum requirements.
Top View
We en plan
vim supertax
�INd
to Oixena tondrig Su�cNaiP •- a"'
J
I
V
U IJ
I
IY
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
i
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC'
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA'
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8
Certificate o/Authorization #9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 ,
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8
FILE COPY QOTRINITYIERD
APPENDIX TTACHIVIENTIREQIIIREMENTS,FOR WIND UPUFT.RESISTANCE
Table
Deck
Application
Type
Description
1A
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
Page
1B
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded. Top Insulation, Bonded Roof Cover
5-
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
7
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8-9
lE-1
Wood
New, Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
10-12
13-15
1E-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
16-17
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
2A
Steel or Structural Concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
17
2B
Steel or Structural Concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
18-20
2C
Steel or Structural Concrete
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
21-25
3A
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
26-28
3B
Concrete
New or Reroof (Tear -Off)
A-3
Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover
29-36
3C
Concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
36
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
37
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
38-39
4C
LWIC
New, Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
40
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-44
5B
CWF
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
45
46
5C
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
5D
CWF
New Reroof (Tear -Off)
46
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 47
6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 48-49
6B Gypsum Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50
6C Gypsum Reroof (Tear -Off) C Mech. Attached Insulation, Bonded Roof Cover 51
6D Gypsum Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 52-57
7B Various Recover F Non -Insulated, Bonded Roof Cover 57
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or 3" Round Insulation Plate, Trufast HD with Trufast 3"
Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment.
➢ Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), CMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast #12 or #14 with Hex Plate or 3" Round
Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast #12 or #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration and
engage the top flute of the steel deck.
➢ Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OIVIG 3 in. Galvalume Steel Plate, Dekfast #14 or DekSpike with Hex Plate or 3" Round
Insulation Plate, Trufast HD or CF with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 1-inch embedment. Fasteners installed
with a pilot hole in accordance with the fastener manufacturer's published installation instructions.
Exterior Research and Design, LLC. d/b/a Trinity( ERD - rH - — Evaluation-Report3520:03:04=R20-far-FC2533�ii9=— -
- -- _- Certificate-of-Authorization-#950 -_ -- - - EDITION (2017) FBC NOWHVH EEVALUATION Revision 20: 09/14/2017
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintiastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 1 of 57
VrTRINITYIERD
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya n u rate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board or gypsum -based roof board that meets the QA requirements
of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover),
whereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck
listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper
codified and/or FBC Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
> Hot asphalt (HA): Full coverage at 25-30 Ibs/square
>
Ashland Pliodeck (A-PD):
Continuous 0.75 inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below.
>
Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS):
Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c.
>
Millennium One Step Foamable Adhesive (M-OSFA):
Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
>
Millennium PG-1 Pump Grade Adhesive (M-PG1):
Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.
>
OMG OlyBond 500 or OlyBond Green (OB500):
Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot)
>
ICP Adhesives CR-20:
Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c.
>
Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, boards shall be staggered from layer -to -layer.
>
Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanu rate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
> Ashland Pliodeck (A-PD) @ 12-inch o.c. MDP -105.0 psf (Min. 1.0-inch)
> Ashland Pliodeck (A-PD) @ 6-inch o.c. MDP -277.5 psf (Min. 1.0-inch)
> Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS):
?> Millennium One Step Foamable Adhesive (M-OSFA):
> Millennium PG-1 Pump Grade Adhesive (M-PGI):
> OMG OlyBond 500 (OB500):
> OMG OlyBond 500 (OB500):
> OMG OlyBond 500 (OB500):
> OMG OlyBond 500 (OB500):
> ICP Adhesives CR-20:
MDP
-120.0 psf
(Min. 1.0-inch)
MDP
-157.5 psf
(Min. 1.0-inch)
MDP
-157.5 psf
(Min. 1.0-inch)
MDP
-45.0 psf
(Min. 0.5-inch Multi -Max FA3)
MDP
-187.5 psf
(Min. 0.5-inch ISO 95+GL)
MDP
-315.0 psf
(Min. 0.5-inch ENRGY 3)
MDP
-487.5 psf
(Min. 0.5-inch ACFoam II)
MDP
-117.5 psf
(Min. 1.0-inch)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for
Zone 2/3 enhancements.
10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
Exterior Research and Design, U.C. d/b/a Trinity) ERD - -_ - Evaluation-Report3520:03:04-R20forFL2533�iJ
- - _--ertificate-of-Authorization#t950 _ - - 6 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 2 of 57
��TRINI-rYJERD
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Concrete Deck or Recover Applications using System Type D, the insulation is optional.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1
15. Unless otherwise noted, refer to the following references for bonded base, Dlv or cao sheet aoDlications
' - _ '_'
- ' -
• F : CERTAINTEED FIINTW_ STIC��'M_ O ID FIED BR_ _MEN CO_ MPONE TS_LBt;,APPLICATION MET_
Material
Application
Reference
Layer
BP -AA
Base
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
(Base and Ply sheets, Asphalt -Applied)
Hot asphalt at 20-40 Ibs/square
Ply
One or more Flintglas Ply 4; Flintglas Premium Ply 6
BP-AA2
Base
Yosemite Venting Base
Hot asphalt in 24-inch diameter spots in 30-
(Base, Spot -Asphalt -Applied)
inch grid pattern
BP-AA3
Base
Yosemite Venting Base
Hot asphalt in 9-inch diameter spots in grid
(Base, Spot -Asphalt -Applied)
pattern noted herein.
BP-AA4
Base
Yosemite Venting Base
Hot asphalt in 9-inch wide ribbons spaced
(Base, Strip -Asphalt -Applied)
as noted herein.
BP-CA2
Base/Ply
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
Henry #903 Adhesive at 1.5 gal/square
BP CA3
Base/Ply
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-inch o.c.
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-AA
Ply
One or more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap
Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual
(SBS, Asphalt -Applied)
Hot asphalt at 20-40 Ibs/square
Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;
Flintlastic GMS; Flintlastic GMS CoolStar
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CAl
FlintBond Brush or Karnak No. 81 Cold
Note:
Base ply cures overnight prior to application of the ply or cap ply.
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
(SBS, Cold -Applied)
Process Modified Bitumen Adhesive Brush
Cap
Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar,
Grade at 1 gal/square
Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CA2
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Cap
Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual
(SBS, Cold -Applied)
Henry #903 Adhesive at 1.5 gal/square.
Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;
Flintlastic GMS; Flintlastic GMS CoolStar
Exterior Research and Design, LLC. d/b/a Trinity) ERD TM Evaluation-Report-3520:03-04-R-20-forFL2533=R14-
Cfica _ertite of Authod3#9 zation5n1_ o cD1ITlW(2017) F9_C NON-HVHZ EVALUATION Revision 20: 09/14/2017
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 3 of 57
��TRINITYJERD
CE&TAINTEHD F_LINTLASTIC®yMODIF ED BITUMEN COMP,oNENTS.&APPLICATION METHODS (CONTINUED)
Reference Layer Material
Application
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CA3
(SBS, Cold -Applied)
Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-inch o.c.
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Ca p
Flintlastic Ca p 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual
Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;
Flintlastic GMS; Flintlastic GMS CoolStar
Base
Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
SBS-TA
Ply
One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T
(SBS, Torch -Applied)
Torch -Applied
Cap
Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-FR;
Flintlastic GTS-FR CoolStar; FlintClad
APP-TA
(APP, Torch -Applied)
Base
One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus
Torch -Applied
Cap
Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR
CoolStar
SBS-SA-H
Base/Ply
Black Diamond Base Sheet; Flintlastic Ultra Glass SA
(SBS, Self -Adhering, Hybrid Systems)
Self -Adhering
Base
Flintlastic SA PlyBase; Flintlastic SA Mid Ply
SBS-SA
(SBS, Self -Adhering)
1.
Self -Adhering
g
ply
Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Cap
Flintlastic SA Cap; Flintlastic SA Cap CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar
16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity l ERD _ vatuation-Report-352D:0-3-04-R20-for-FL2533=R19
Certificate_ofA_uthorization-Certificate_ _ _ uT"EDITION (2017)-F NON=HVHZ EVALUATION Revision 20: 09/14/2017
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5947 Appendix 1, Page 4 of 57
WN
RINITY ERD
r
TABLE 1`A�,{WOOD' ECKS NEW CONSTRl1CT10 oR REROOF
(•TEAR -OFF)
SYSTEM TYp'A 2 NICHANICALL`YAT3TACHED
y ANCHOR,ED
INSULATION, BONU.EDyRQOF GO\/ER
Sys. Deck Anchor Sheet Base Insulation
Top Insulation
Roof
Cover (Note 14)
MDP
No. (Note 1) Type Fasteners Attach Type Attach
Type
Attach
Base
Ply Cap
(psf)
SELF ;ADHERING'-VvrEMS:' ' � ''
Min. 0.25-inch
Min. 19/32-
Glasbase, All
Weather Empire,
32 ga., 1-5/8-
9-inch o.c. in 4-inch
Min. 1.5-inch-
inch
Plexiglas Base,
inch dia. tin
lap and 12-inch o.c.
ACFoam Il,
Dens Deck
W-1 _
plywood at
Flintlastic Base 2
caps with it ga.
in two (2), equally
FlintBoard ISO,
HA
primed with
HA
SBS-SA
(Optional)
SBS-SA
-45.0'
max. 24-
Poly SMS; Ultra Poly
o
annular ring
spaced, staggered
ENRGY-3, H-Shield
FlintPrime or
SBS-SA
inch spans
SMS; Yosemite
shank nails
center rows
or Multi -Max FA3
FlintPrime SA
Min. 19/32-
Glasbase, All
32 ga., 1-5/8-
8-inch o.c. in 3-inch
Min. 1.5-inch
HA full
Min. 0.25-inch
HA full
inch
Weather Empire,
P
inch dia. tin
la and 8-inch o.c.
P
ACFoam II,
coverage or
g
Dens Deck
coverage or
g
W-2
plywood at
Plexiglas Base, Poly
caps with 11 ga.
in three (3), equally
FlintBoard ISO,
0B500, M-
primed with
OB500, M-
SBS-SA
(Optional)
SBS-SA
max. 24-
SMS or Ultra Poly
annular ring
spaced, staggered
ENRGY-3, H-Shield
OSFA, A-PD,
FlintPrime or
OSFA, A-PD, D-
SBS-SA
-52.5
inch spans
SMS
shank nails
center rows
or Multi -Max FA3
D-IS or CR-20,
FlintPrime SA
IS or CR-20, 6-
4-inch o.c.
inch o.c.
Min. 19/32-
32 ga., 1-5/8-
8-inch o.c. in 3-inch
Min. 1.5-inch
Min. 0.25-inch
inch
Yosemite Venting
inch dia. tin
lap and 8-inch o.c.
ACFoam II,
Dens Deck
W-3
plywood at
Base Sheet
caps with 11 ga.
in three (3), equally
FlintBoard ISO,
HA
primed with
HA
SBS-SA
(Optional)
SBS-SA
-52.5
max. 24-
annular ring
spaced, staggered
ENRGY-3, H-Shield
FlintPrime or
SBS-SA
inch spans
shank nails
center rows
or Multi -Max FA3
FlintPrime SA
Min. 19/32-
Glasbase, All
32 ga., 1-5/8-
8-inch o.c. in 3-inch
(Optional) Min.
HA full
Min. 0.25-inch
SECUROCK
HA full
inch
Weather Empire,
inch dia. tin
lap and 8-inch o.c.
1.5-inch ACFoam
coverage or
Gypsum -Fiber
coverage or
W-4
plywood at
Plexiglas Base, Poly
caps with 11 ga.
in three (3), equally
II, FlintBoard ISO,
OB500, M-
Roof Board
OB500, M-
SBS-SA
(Optional)
SBS-SA
max. 24-
SMS or Ultra Poly
annular ring
spaced, staggered
ENRGY-3, H-Shield
OSFA, A-PD,
Primed with
OSFA, A-PD, D-
SBS-SA
-60.0
inch spans
SMSD-IS
shank nails
center rows
or Multi -Max FA3
or CR-20,
FlintPrime or
IS or CR-20, 6-
4-inch o.c.
FlintPrime SA
inch o.c.
Min. 0.25-inch
Min. 19/32-
32 ga., 1-5/8-
8-inch o.c. in 3-inch
(Optional) Min.
SECUROCK
inch
Yosemite Venting
inch dia. tin
lap and 8-inch o.c.
1.5-inch ACFoam
Gypsum -Fiber
W-5
plywood at
Base Sheet
caps with 11 ga.
in three (3), equally
II, FlintBoard ISO, HA
Roof Board
HA
SBS-SA
(Optional)
SBS-SA
-60.0
max. 24-
annular ring
spaced, staggered
ENRGY-3, H-Shield
primed with
SBS-SA
inch spans
shank nails
center rows
or Multi -Max FA3
FlintPrime or
FlintPrime SA
HYBRIDSYSTEMS
r,'
�.,4.
M1.5 ih cn
m
Min. 19/32-
All
Weather Ell lpire
32 ga.,1-5/8-_._
9-inch o.c. in 4-inch
inch
,
Plexiglas Base,
inch dia, tin
lap and 12-inch o.c.
ACFoam II,
(Optional)
SBS-AA,
W-6
plywood at
Flintlastic Base 20
caps with 11 ga.
in two (2), equally
FlintBoard I50, HA
None
N/A
SBS-SA-H
BP -AA, SBS-
SBS-TA
-45.0'
max. 24-
Poly SMS; Ultra Poly
annular ring
spaced, staggered
ENRGY-3, H-Shield
AA, SBS-TA
or APP-
inch spans
SMS; Yosemite
shank nails
center rows
or Multi -Max FA3
or APP-TA
TA
Exterior Research and Design, LLC. d/b/a Trinity[ERD Evaluation -Report 3520:03-.04-R20-forFL-2533=R19�
_ CeTtificate of-Authorization-#9503 _ — - - -_ - = 6gEDI 11UN Z017) FBC NON-HVHz EVALUATION Revision 20: 09/14/2017
• Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-SB47 Appendix 1, Page 5 of 57
",,ITwNIi-YlERD
TABLE 3A WOOD DECKS ANEW CONSTRUCTIO oR REROOF (TEAR -OFF)
Y? SYSTEM TYPE A 2 MECHANICALLY ATTACHED ANCHOR SHEET, 66NDEDINSULATION, BONDEDROOF CO�UER
xBase
Sys.
Deck
Anchor Sheet
Insulation
Top Insulation
Roof
Cover (Note 14)
MDPi
No.
(Note 1)
Type
Fasteners
Attach
Type
Attach
Type
Attach
Base
Ply Cap
(psf)
Min. 19/32-
32 ga., 1-5/8-
8-inch o.c. in 3-inch
Min. 1.5-inch
inch
Glasbase; Flintglas
inch dia. tin
lap and 8-inch o.c.
ACFoam II,
(Optional) SBS-AA,
W-7
plywood at
Premium Ply 6;
caps with 11 ga.
in three (3), equally
FlintBoard ISO,
HA
None
N/A
SBS-SA-H
BP -AA, SBS- SBS-TA
-60.0
max. 24-
Yosemite
annular ring
spaced, staggered
ENRGY-3, H-Shield
AA, SBS-TA or APP-
inch
shank nails
center rows
or Multi -Max FA3
orAPP-TA TA
CONVENTION4
isTEMs:
>.
�„
s,
Min. 19/32-
Glasbase, All
Weather Empire
32 ga 1 5/8-
9-inch o.c. in 4-inch
Min. 1.5-inch
Min. 0.25-inch
inch
,
Plexiglas Base,
inch dia. tin
lap and 12-inch o.c.
ACFoam II,
Dens Deck
BP -AA,
(Optional)
SBS-AA,
W-8
plywood at
Flintlastic Base 20;
caps with 11 ga.
in two (2), equally
FlintBoard ISO,
HA
primed with
HA
SBS-AA,
BP -AA, SBS-
SBS-TA
-45.0*
max. 24-
Poly SMS, Ultra Poly
annular ring
spaced, staggered
ENRGY-3, H-Shield
FlintPrime (ASTM
SBS-TA or
AA, SBS-TA
or APP-
inch spans
SMS; Yosemite
shank nails
center rows
or Multi -Max FA3
D41) primer
APP-TA
or APP-TA
TA
Min. 19/32-
Glasbase, All
32 ga., 1-5/8-
8-inch o.c. in 3-inch
Min. 1.5-inch
HA full
Min. 0.25-inch
HA full
inch
Weather Empire,
inch dia. tin
lap and 8-inch o.c.
ACFoam II,
coverage or
Dens Deck
coverage or
BP -AA,
(Optional)
SBS-AA,
W-9
plywood at
Plexiglas Base, Poly
caps with it ga.
in three (3), equally
FlintBoard I50,
OB500, M-
primed with
OB500, M-
SBS-AA,
BP -AA, SBS-
SBS-TA
max. 24-
SMS or Ultra Poly
annular ring
spaced, staggered
ENRGY-3, H-Shield
OSFA, A-PD,
FlintPrime (ASTM
OSFA, A-PD, D-
SBS-TA or
AA, SBS-TA
or APP-
-52.5
inch spans
SMS
shank nails
center rows
or Multi -Max FA3
D-IS or CR-20,
D41) primer
IS or CR-20, 6-
APP-TA
or APP-TA
TA
4-inch o.c.
inch o.c.
Min. 19/32-
32 ga., 1-5/8-
8-inch o.c. in 3-inch
Min. 1.5-inch
Min. 0.25-inch
inch
Yosemite Venting
inch dia. tin
lap and 8-inch o.c.
ACFoam II,
Dens Deck
BP -AA,
(Optional)
SBS-AA,
W-30
plywood at
Base Sheet
caps with it ga.
in three (3), equally
FlintBoard I50,
HA
primed with
HA
SBS-AA,
SBS BP -AA, -
SBS -TA
-52.5
max. 24-
annular ring
spaced, staggered
ENRGY-3, H-Shield
FlintPrime (ASTM
SBS-TA or
AA, SBS-TA
or APP-
inch spans
shank nails
center rows
or Multi -Max FA3
D41) primer
APP-TA
or APP-TA
TA
Min. 19/32-
Glasbase, All
32 ga., 1-5/8-
8-inch o.c. in 3-inch
(Optional) Min.
HA full
HA full
inch
Weather Empire,
inch dia. tin
lap and 8-inch o.c.
1.5-inch ACFoam
coverage or
Min. 0.25-inch
coverage or
BP -AA,
(Optional)
SBS-AA,
W-11
plywood at
Flexiglas Base, Poly
caps with 11 ga.
in three (3), equally
II, FlintBoard ISO,
OB500, M-
SECUROCK
OB500, M-
SBS-AA,
BP -AA, SBS-
SBS-TA
max. 24-
SMS or Ultra Poly
annular ring
spaced, staggered
ENRGY-3, H-Shield
OSFA, A-PD,
Gypsum -Fiber
OSFA, A-PD, D-
SBS-TA or
AA, SBS-TA
or APP-
60.0
inch spans
SMS
shank nails
center rows
or Multi -Max FA3
D-IS or CR-20,
Roof Board
IS or CR-20, 6-
APP-TA
or APP-TA
TA
4-inch o.c.
inch o.c.
Min: 19/32-
32 ga., 1-5/8-
8-inch o.c. in 3-inch
(Optional) Min.
inch
Yosemite Venting
inch dia. tin
lap and 8-inch o.c.
1.5-inch ACFoam
Min. 0.25-inch
BP -AA,
(Optional)
SBS-AA,
W-12
plywood at
Base Sheet
caps with 11 ga,
in three (3), equally
II, FlintBoard I50,
HA
SECUROCK
HA
SBS-AA,
-
SBS-
-
TA SBS
max. 24-
annular ring
spaced, staggered
ENRGY-3, H-Shield
Gypsum -Fiber
SBS-TA or
AA, SBS-TA
or APP-
-60.0
inch spans
shank nails I
center rows
or Multi -Max FA3
Roof Board
APP-TA
or APP-TA
TA
Exterior Research and Design, LLC. d/b/a Trinity I ERD TM Evaluation Report 3520.03.04-R20 for FL2533-R39
Certificate of Authorization #950 _ _ _ _ _ _ _ � _EDITION-.(2 MFBC—N0N-HV+IZ EVAIi)ATION— - _ -_ _ -_ _ _ _ _- —_ _
- - -evasion- 14 2017 - -- -
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 6 of 57
V TRINITY (ERD
TABLE=16 WOOD DECKS NV CONSTOF 6N, REROOF (TEAR-UFf) oMR COVER
,
SYSTEMTYPE B; MECHAN(CALLYIATTACHE BASE=INSULATION, BONDED TOP INSULATJO,N, BONDED�ROOF
CODER
System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14)
No.
(Note 1)
Type Fasteners Attach
Type
Attach
Base
Ply Cap
MDP (psf)
HYBRID$YSTEMS ; * s
Min. 15/32-inch
Min. 1.5-inch ACFoam
FlintFast #12 or
exterior grade
II, FlintBoard ISO, H-
#14 with
1 per 1.33
Min. 1.5-inch ACFoam II,
HA, D-IS, M-
W-13
plywood at max. 24-
Shield or FlintBoard
FlintFast 3"
ftz
FlintBoard ISO, H-Shield or
OSFA, M-PG1
SBS-SA-H
(Optional) APP-TA
APP-TA
67.5
inch spans
ISO".
Insulation Plates
FlintBoard ISO".
or OB500
Co9VENTIONAL;SYSTEMS
Min. 23/32-inch
Min. 0.5-inch Structodek
exterior grade
Min. 1.5-inch ACFoam
High Density Fiberboard
(Optional) BP -AA,
W-14
plywood at max. 24-
II, FlintBoard ISO,
Note 2
1 per 2 ftz
Roof Insulation, min. 0.75-
HA
BP -AA or
SBS-AA, SBS-TA or
SBS-AA, SBS-
-45.0*
inch spans
ENRGY 3, H-Shield
inch FescoBoard
SBS-AA
APP-TA
TA or APP-TA
(homogeneous)
Min. 23/32-inch
Min. 1.5-inch ACFoam
Min. 0.25-inch SECUROCK
W-15
exterior grade
II, FlintBoard
Note 2
z
1 per 2 ft
Gypsum -Fiber Roof Board,
HA
BP -AAA SBS-
(Optional) BP -AA,
SBS-AA, SBS-
plywood at max. 24-
ENRGY 3, H-Shield iel
Dens Deck or Dens Deck
AA, SBS-TA
SBS-AA, SBS-TA or
TA or APP-TA
-45.0*
inch spans
Prime
or APP-TA
APP-TA
Min. 15/32-inch
Min. 1.5-inch ACFoam
FlintFast #12 or
Optional additional layer(s)
W-16
exterior grade
II, FlintBoard ISO, H-
#14 with
1 per 1.33
of base insulation followed
HA, D-IS, M-
plywood at max. 24-
Shield or FlintBoard
FlintFast 3"
ftz
by Min. 0.25-inch SECUROCK
OSFA, M-PG3
APP-TA
(Optional) APP-TA
APP-TA
-90.0
inch spans
ISO".
Insulation Plates
Gypsum -Fiber Roof board
or OB500
Exterior Research and Design, I.I.C. d/b/a Trinity ERD Evaluation Report 3520.03.04-R20 for F1.2533-1139
CeLtic_ate of_Authorization #9503 _ _ 6'"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017
Prepared by: Robert Nieminen, PE-59166 Certain7eed Flintlasfic® flAodified Bitumen Roof Systems; (610) 651-5847 - —Appendix 1, Page 7 of 57 -
�rTRINITYIERD
t
1C tIN00D1DEQKSNEW CONSTRUCTION, REROOF (TEAR -OFF) oR RECOVER
- - SYSTEM i'YPE�C: ;MECHANICALLY.ATTACHED�INSULA�ThON, BONDED ROOF GOUER
System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP
No (Note 1) Type Fasteners Attach Base Ply Cap (psf)
SELF=A DHERINGSYSTEMS:'e.
Min. 15/32-inch (Optional) One or more Flintfast 3 in. Insulation
Plates with FlintFast #12 1 per 3.2 ft2 SBS-SA (Optional) SBS- *
W-17 plywood at max. 24- layers, any combination, Min. um -Finch Roof Board SBS-SA 30.0
Gypsum -Fiber Roof Board p
inch spans loose laid or #14 SA
Min. 19/32-inch
(Optional) One or more
Apply FlintPrime or
W-18
exterior grade plywood
layers, any combination,
Min. 0.25-inch Dens Deck
Note 2
1 per 1.33 ftZ
p
FlintPrime SA to
(Optional) SBS-
SBS-SA
45.0
at max. 24-inch spans
loose laid
board & plates,
SA
followed by SBS-SA
Min. 19/32-inch
(Optional) One or more
Min. inch S
Flintfast 3 in. Insulation
W-19
exterior grade plywood
layers, any combination,
m- Roof BoarOCK
Gypsum -Fiber Roof Board
Plates with FlintFast #12
1 per 2.7 ft2
P
SBS-SA
(Optional) SBS-
SBS-SA
45.0 *
at max. 24-inch spans
loose laid
or #14
SA
Min. 19/32-inch
(Optional) One or more
Min.1.5-inch ACFoam II,
Flintfast 3 in. Insulation
Apply FlintPrime or
W-20
plywood at max. 24-
layers, any combination,
ENRGY 3, H-Shield, Multi -Max
Plates with FlintFast #12
1 per 2 ft2
FlintPrime SA to
(Optional) SBS-
SBS-SA
45.0 *
inch spans
loose laid
FA3 or FlintBoard ISO
or #14
board & plates,
SA
followed byres -SA
Flintfast #14 HD with
Min. 15/32-inch
(Optional) One or more
FlintFast 3" Insulation
Apply FlintPrime to
W-21
plywood at max. 24-
layers, any combination,
Min. 1.5-inch FlintBoard ISO
Plates or Trufast HD
1 per 1.6 ft2
board & plates,
(Optional) SBS-
SBS-SA
-52.5
inch spans
loose laid
with Trufast 3" Metal
followed by SBS-SA
SA
Insulation Plates
Min. 19/32-inch (Optional) One or more Min. 1.5-inch ACFoam II,
Apply FlintPrime or
W-22 plywood at max. 24- layers, any combination, ENRGY 3, H-Shield, Multi -Max
Note 2
1 per 1.45 ft2
p
FlintPrime SA to
(Optional) SBS-
SBS-SA 60.0
inch spans loose laid FA3 or FlintBoard ISO
board & plates,
SA
followed by5BS-SA
HYert <'
Flintfast 3 in. Insulation
Min. 15/32-inch
(Optional) One or more
Min. 0.25-inch Dens Deck;
(Optional) BP-
W-23
plywood at max. 24-
p y
layers, an combination,
y Y
Dens Deck Prime
Plates with FlintFast #12
2
1 per 2 ft
SBS-SA-H
AA, SBS-AA, SBS-
SBS-
SBS-AA, SBS-TA
-30.0*
inch spans
loose laid
or #14
TA or APP-TA
or APP-TA
FlintFast #14 HD with
Min. 15/32-inch
(Optional) One or more
FlintFast 3" Insulation
W-24
plywood at max. 24-
layers, any combination,
Min. 1.5-inch FlintBoard ISO
Plates or Trufast HD
1 per 1.6 ft2
SBS-SA-H
(Optional) SBS-
SBS-TA or APP-
-52.5
inch spans
P
loose laid
with Trufast 3" Metal
TA or APP-TA
TA
Insulation Plates
Min. 15/32-inch
(Optional) One or more
Min. 1.5-inch ACFoam II,
W-25
plywood at max. 24-
layers, any combination,
FlintBoard ISO, ENRGY 3 or
Note 2
1 per 1.33 ft2
SBS-SA-H
(Optional) BP -AA
SBS-AA
-52.5
inch spans
loose laid
Multi -Max FA3
or SBS-AA
Min. 19/32-inch
(Optional) One or more
Min. 1.5-inch ACFoam II,
(Optional) BP-
W-26
plywood at max. 24-
layers, any combination,
FlintBoard ISO, H-Shield,
Note 2
1 per 1.45 ft2
SBS-SA-H
AA, SBS-AA, SBS-
SBS-AA, SBS-TA
-60.0
inch spans
loose laid
FlintBoard ISO"
TA or APP-TA
or APP-TA
Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report 3520.03.04-R20 for FL2533-R19
Certificate-ofAuthorizatioa49503 FT" FnITION (2017)-ESC_NON=HVH2 EVALUATION Revision 20 09J-14/2017
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 8 of 57
��TRINITYJERD
TABL KS E 1`C WOOD DEC'=NEVII/CONSTRUCTION,REROOF iTEAR-OFFj on RECOVER
SYSTEM TYPE(GMECHfCA�LL-YATTAGHED;INSULATION,
BONDED�RO,OF COVER _ ... _ ..,_, ,.
System Deck Top Insulation Layer Roof Cover (Note 14)
Base Insulation Layer MDP
No. (Note 1)
Type Fasteners Attach Base Ply Cap (psf)
Min. 15/32-inch
(Optional) Min. 1.5-inch, One
Min. 1.5-inch ACFoam II,
Flintfast 3 in. Insulation
(Optional) SBS-
W-27
plywood at max. 24-
or more layers, any
FlintBoard ISO, H-Shield,
Plates with FlintFast #12
1 per 1.33 ftz
SBS-SA-H
AA, SBS-TA or
SBS-AA, SBS-TA
-75.0
inch spans
combination, loose laid
FlintBoard ISO„
or #14
APP-TA
or APP-TA
Min. 19/32-inch
(Optional) One or more
Min. 1.5-inch ACFoam Il,
W-28
exterior grade plywood
layers, any combination,
FlintBoard ISO, ENRGY 3 or
Note 2
1 per 1.33 ft2
SBS-SA-H
(Optional) SBS-
SBS-TA or APP-
at max. 24-inch spans
loose laid
Multi -Max FA3
TA or APP-TA
TA
82 5
- CokviNTIONACSYSTEMS
_ ,='_
• `
` r ! xr
t z
(Optional) BP-
Min. 23 32-inch
/
(Optional) One or more
Min. 0.5-inch Structodek High
W-29
exterior grade plywood
layers, any combination,
Density Fiberboard Roof
Insulation, min. 0.75-inch
Note 2
1 per 2 it'
BP -AA or SBS-AA
AA, SBS-AA, SBS-
SBS-AA, SBS-TA
45.0*
at max. 24-inch spans
loose laid
FescoBoard (homogeneous)
TA or APP-TA
or APP-TA
Min. 15/32-inch
(Optional) One or more
Min. 0.25-inch SECUROCK
Gypsum -Fiber Roof Board,
FlintFast #12 or #14 HD
BP -AA, SBS-AA,
(Optional) BP -
W-30
plywood at max. 24-
p
layers, an combination,
y y
Dens Deck or Dens Deck
with FlintFast 3"
2
1 per 2 ft
SBS-TA or APP-
AA, SBS-AA, SBS-
SBS-AA, SBS-TA
-45,0*
inch spans
loose laid
Prime
Insulation Plates
TA
TA or APP-TA
or APP-TA
Min. 15/32-inch
(Optional for Recover) Min.
FlintFast #12 or #14 HD
W-31
plywood at max. 24-
1.5-inch, One or more layers,
Min. 0.25-inch SECUROCK
with i3"
z
1 per 1.45 ft
APP-TA
(Optional) APP-
APP-TA
inch
inch spans
any combination, loose laid
Roof Board
InsulatLioonn Plates
TA
-60.0
Min. 19/32-inch
(Optional for Concrete or
Recover) Min. 2-inch ACFoam
Min. 0.5-inch SECUROCK
FlintFast #12 or #14 HD
BP -AA, SBS-AA,
(Optional) BP-
W-32
exterior grade plywood
II, FlintBoard, H-Shield or
Gypsum -Fiber Roof Board
with
z
1 per 1.78 ft
SBS-TA or APP-
AA, SBS-AA, SBS-
SBS-AA, SBS-TA
-60.0
at max. 24-inch spans
ENRGY 3, loose laid.
Insulation Plates
Lion Plaasttes
e
TA
TA or APP-TA
or APP-TA
Min. 15/32-inch
(Optional for Recover) Min.
FlintFast #12 or #14 HD
W-33
plywood at max. 24-
1.5-inch, One or more layers,
y
Min. 0.25-inch SECUROCK
with FlintFast 3"
x
1 per 1.33 ft
APP-TA
(Optional) APP-
APP-
APP-TA
inch spans
any combination, loose laid
Gypsum -Fiber Roof Board
Insulation Plates
TA
67.5
Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report 3520.03.04-R20 for F1.2533-1119
_— — _ Certificate-of-Autharization,#95Q3 _ 6P EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017
— _
Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 — — Appendix 1, Page 9 ot 57
TRINITY I ERD
;, TABLE D DE •,
D`
= CKS— NEW�`CONSTRUCTION, REROOF (TEAR -OFF) RECOVER
oR
" 3 SYSTEM TYPED INSULATED,
IVIECHANICALLYATTACH_ED,BASE SHEET BONDED ROOF CODER
system Deck Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP
No.
(Note 1)
.
Type
..
Attach
Base
Fasteners
Attach
ply
Cap
(psf)
SELF-ADHERING'5YSTEMS.:",
:.
_
Min. 19/32-inch
Min. 1.5-inch, One
8-inch o.c. at min. 3-inch lap and 8-
W-34
plywood at max 24-
or more layers,
Prelim.
Attach
Flintlastic SA NailBase
Note 2
inch o.c. in two (2), equally spaced,
staggered center rows; Stress plates
gg p
(Optional)
SBS-SA
*
inch spans
any combination
shall be primed with FlintPrime
SBS-SA
-82.5
(ASTM D41) primer or FlintPrime SA
Flintfast 3 in. Insulation Plates
Min. 15/32-inch
Min. 1.5-inch, One
with FlintFast #12 or #14•
6-inch o.c, at min. 2-inch lap and 6-
W-35
plywood at max 24-
or more layers,
Prelim.
Attach
Flintlastic SA NailBase
Trufast 3" Metal Insulation
inch o.c. in three (3), equally spaced,
q y p
staggered center rows; Stress
rows;
(Optional)
SBS-SA
inch spans
any combination
Plates with DP or HD; OMG 3
plates
shall be primed with FlintPrime
SBS-SA
97.5*
in. Round Metal Plates with
OMG #14 HD
(ASTM D41) primer or FlintPrime SA.
Flintfast 3 in. Insulation Plates
Min. 15/32-inch
Min. 1.5-inch, One
with FlintFast #12 or #14;
6-inch o.c. at min. 2-inch lap and 6-
W-36
plywood max 24-
or more layers,
Prelim.
Flintlastic SA NailBase
Trufast 3" Metal Insulation
inch o.c. in four 4 , equally spaced,
() q y p
(Optional)
inch spans
s
any combination
Attach
Plates with DP or HD; OMG 3
staggered center rows; Stress plates
p
SBS-SA
SBS-SA
-127.5 *
in. Round Metal Plates with
shall be primed with FlintPrime
OMG #14 HD
(ASTM D41) primer or FlintPrime SA.
Flintfast 3 in. Insulation Plates
Min. 15/32-inch
Min. 1.5-inch, One
Prelim.
Glasbase; Plexiglas;
with FlintFast #12 or #14;
6-inch o.c. at 4-inch lap and 6-inch
o.c. in three 3 equally spaced,
() q y p
. W-37
plywood at max 24-
or more layers,
gttach
Flintlastic Base 20; Poly SMS
Trufast 3" Metal Insulation
Plates with DP or HD; OMG 3
,
staggered center rows; Stress plates
SBS-SA-H
SBS-AA, SBS-
_97•5
inch spans
any combination
Base; Ultra Poly SMS Base
y
in. Round Metal Plates with
shall be primed with FlintPrime
TA or APP-TA
OMG #14 HD
(ASTM D41) primer or FlintPrime SA.
Min. 19/32-inch
Min. 1.5-inch, One
Prelim.
Glasbase; Flexiglas;
7-inch o.c. at 3-inch lap and 7-inch
W-38
plywood at max 24-
or more layers,
Attach
Flintlastic Base 20; Poly SMS
Note 2
o.c. in three (3), equally spaced,
SBS-SA-H
SBS-AA, SBS-
305.Q
inch spans
any combination
Base; Ultra Poly SMS Base
staggered center rows
TA or APP-TA
Flintfast 3 in. Insulation Plates
Min. 15/32-inch
Min. 1.5-inch, One
Prelim.
Glasbase; Flexiglas;
with FlintFast #12 or #14;
6-inch o.c. at 4-inch lap and 6-inch o.c.
in four 4, equally
() q y spaced,
W-39
plywood at max 24-
or more layers,
Attach
Flintlastic Base ; oy SMS
20Poly
Trufast 3" Metal Insulation
Plates with DP or HD; OMG 3
staggered center rows; Stress plates
SBS-SA-H
SBS-AA, SBS-
-127.5
inch spans
any combination
Base; Ultra Poly SMS Base
in. Round Metal Plates with
shall be primed with FlintPrime
TA or APP-TA
OMG #14 HD
(ASTM D41) primer or FlintPrime SA.
CONVENTIONRLSYSTEMS " K a .n
.r ixa.
Exterior Research and Design, LLC. d/b/a Trinity I ERD rx Evaluation Report 3520.03.04-R20 for FL2533-R19
Certificate of Authorization #9503 6 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20; 09/14/2017
Prepared by: Robert Nierninen, — — — CMainTeed-Flintlastic®-Modified•Bitumen-Roof Systems,(610)-651-58ppendix-1,P-age-W-of57
�iNInlERD
"'
TABLE
SYSTEM TYPE,DINSULATED
D WOOD' DECKS NEW
,MECHANICAL+LYATfACHED
CONSTRIIC ITIT ON, REROOF (TEAR
BASE SHE
-OFF) oR RE@OVER
T, BONDED ROOF CQUER
System
Deck
Insulation Layer(s)
Base or Anchor Sheet
Roof Cover
(Note 14)
MDP
No.
(Note 1)
Type
Attach
Base
Fasteners
Attach
Ply
Cap
(psf)
Min. 23/32-inch
exterior grade
Min. 1.5-inch, One
Prelim.
Glasbase; All
Weather/Empire Base;
12-inch o.c. at 4-inch lap and 36-inch
BP -AA, SBS-
W-40
plywood at max. 24-
or more layers,
Attach
Plexiglas Base; Flintlastic
Note 2
o.c. in t(2), equally
two y space,
AA, SBS-TA or
SBS-r A, SBS-
-30.0*
inch spans
any combination
Base 20; Yosemite
staggered center rows
APP-TA
TA or APP-TA
Min. 23/32-inch
exterior grade
Min. 1.5-inch, One
Prelim.
Glasbase; All
Weather/Empire Base;
4-inch lap and inch
SBS-
W-41
plywood at max. 24-
more layers,
Attach
Plexiglas Base; Flintlastic
Note 2
o.c. in two (2j, equally spaced,
o.c. in tnch o ( ), ,
AA,BP-SB
AA, 565-TA or
SBS-AA, SBS-
45.0*
inch spans
P
a
any combination
Base 20; Yosemite
staggered center rows
APP-TA
TA or APP-TA
Min. 23/32-inch
exterior grade
Min. 1.5-inch, One
Prelim.
Poly SMS Base; Ultra Poly
4-inch lap and inch
SBS-
W-42
plywood at max. 24-
or more layers,
Attach
SMS Base
Note 2
o.c. in two (2), equally spaced,
o.c. in tnch o ( ), ,
AA,BP-SB
AA, SBS-TA or
SBS-AA, SBS-
-45.0*
inch spans
any combination
staggered center rows
APP-TA
TA or APP-TA
Glasbase; Flexiglas;
Flintfast 3 in. Insulation Plates
Min. 15/32-inch
Min. 1.5-inch, One
Prelim.
Flintlastic Base 20; All
with FlintFast #12 or #14;
6-inch o.c. at 4-inch lap and 6-inch
(Optional) BP -
W-43
plywood at max 24-
or more layers,
Attach
Weather / Empire Base;
Trufast 3" Metal Insulation
o.c. in three (3), equally spaced,
AA, SBS-AA,
SBS-AA, SBS
inch spans
any combination
PolySMS Base; Ultra PolyPlates
with DP or HD; OMG 3
staggered center rows.
SBS-TA or
TA or APP-TA
97 5
SMS Base; Yosemite
in. Round Metal Plates with
APP-TA
OMG #14 HD
W-44
Min. 15/32-inch
plywood at max 24-
Min. 1.5-inch, One
or more layers,
Prelim.
Flintlastic APP Base T
OMG 3 in. Round Metal Plates
6-inch o.c. at 4-inch lap and 6-inch
inch spans
any combination
Attach
with OMG #14 HD
o.c. in three (3), equally'spaced,
APP-TA
APP-TA
_97,5
staggered center rows.
Min. 15/32-inch
One or more
layers, any
Prelim.
Glasbase; Flexiglas;
Flintlastic Base 20; All
Flintfast 3 in. Insulation Plates
8-inch o.c. at 4-inch lap and 8-inch
(Optional) BP-
W-45
plywood at max 24-
thickness or
Attach
Weather / Empire Base;
with FlintFast #14; Trufast 3"
Metal Insulation Plates
o.c. at three (3) equally spaced,
AA SBS-AA,
SBS-AA, SBS-
-97.5
inch spans
combination
Poly SMS Base; Ultra Poly
with
Trufast HD
staggered center rows
SBS-TA or
TA or APP TA
SMS Base; Yosemite
APP-TA
Min. 19/32-inch
Min. 1.5-inch, One
Prelim.
Glasbase; Flexiglas,
Flintlastic Base 20• Poly SMS
7-inch o.c. at 3-inch lap and 7-inch
BP -AA, SBS-
W-46
plywood at max 24-
or more layers,
Attach
Base; Ultra Poly SMS Base;
Note 2
o.c. in three (3), equally spaced,
AA, SBS-TA or
SBS-AA, SBS-
105.0
inch spans
any combination
Yosemite
staggered center rows
APP-TA
TA or APP-TA
Min. 19/32-inch
Min. 1.5-inch, One
Prelim.
OMG 3 in. Round Metal Plates
7-inch o.c. at 3-inch lap and 7-inch
W-47
plywood at max 24-
or more layers,
Attach
Flintlastic APP Base T
with OMG #14 HD or Dekfast
o.c. in three (3), equally spaced,
APP-TA
APP-TA
-105.0
inch spans
any combination
Hex Plate with Dekfast #14
staggered center rows
Flintfast 3 in. Insulation Plates
Min. 15/32-inch
Min. 1.5-inch, One
Prelim.
Glasbase; Flexiglas;
Flintlastic Base 20; Poly SMS '
with FlintFast #12 or #14;
Trufast 3" Metal Insulation
6-inch oat 4-inch l
.c. ncap and 6-inch
(Optional) BP -
W-48
plywood max 24-
inch spanss
or more layers,
any combination
Attach
Base; Ultra Poly SMS Base;
Plates with DP HD; OMG 3
or
O.C. in four (4), equally spaced,
AA, SBS-AA,
SBS-TA or
SBS-AA, SBS-
TA or APP-TA
-127.5
Yosemite
in. Round Metal Plates with
staggered center rows.
APP-TA
OMG #14 HD
Exterior Kesearcn and Design, LLC. d/b/a Trinity I ERD
Evaluation Re ort 3520 03 04 R20 f F
Certificate of Authorization #9503 TM P or L2533-R39
6 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017
Prepared by: Ro ert iemmen, — - CertairtTved-Flintlastic01-Modified-Bitumen-Roof-Systems;-(610)-651-584T Appendix 1, Pa 11 of 57
��TRINITYJERD
TABLE 1D WOOD�DECKS:y,NEWCONSTRUCTION fTE�" aR OF ) oREC VER
�R„EROO
r SYSTEM TYPED INSULATED, MECHANIGALIY�ATI ACHED
v Bl15ExSHEET, BdNDEO ROOF,CO�VER ,
,. :.
System
Deck
Insulation Layer(s)
Base or Anchor Sheet
Roof Cover (Note 14)
MDP
No.
(Note 1)
Type
Attach
Base
Fasteners
Attach
ply
Cap
(psf)
W-49
Min. 15/32-inch
plywood at max 24-
Min. 1.5-inch, One
or more layers,
prelim.
Flintlastic APP Base T
OMG 3 in. Round Metal Plates
6-inch o.c. at 4-inch lap and 6-inch
inch spans
any combination
Attach
with OMG #14 HD
O.C. in four (4), equally spaced,
APP-TA
APP-TA
127.5
staggered center rows.
COLO'APPLIEO
SYSTEMS:.,
Glasbase; Flexiglas Base;
Flintlastic Base 20; All
Min. 15/32-inch
Min. 1-inch, One
Loose-
Weather Em ire Base
/ p
Flintfast 3 in. Insulation Plates
8-inch o.c. at 4-inch la and 8-inch
p
W-50
plywood max 24-
or more layers,
laid
Yosemite Venting Base;
with FlintFast #12 or #14;
o.c. in three (3), equally spaced,
(optional)
SBS-CA1
inch spans
s
any combination
Flintlastic Pol SMS Base;
y
Trufast 3" Metal Insulation
staggered center rows
SBS-CAl
-52.5
Flintlastic Ultra Poly SMS
Plates with DP or HD
Base
Exterior Research and Design, U.C. d/b/a Trinity) ERD TM Evaluation Report 3520.03.04-R20 for FL2533-R19
Certificate of Authorization #9503 6 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017
Prepared by: Robert Nieminen; PE= - - _ _ - - rtainTeed-Flintlastic®-Modified-Bitumen-Roof-Systems;{6-10}651-5847 opp_encl l,_Page12 of 57
QOTRINITYIERI)
TABLEfl'E rl WOODS DECK KS ' EW C�� N TRUCTION oR REROOF (TEAR -OFF) '
ac,t
SYSTEIVITYPE,E NON INSULATER,MECHANICALLiYAT+TACHEDBASEXSHEE�T,,BONDEDROOFCOVER
System Deck Base Sheet Roof Cover (Note 14) MDP
No. (Note 1) Base Fasteners Attach Ply Cap (psf)
SELF -ADHERING SYSTEMS.
9-inch o.c. at min. 3-inch lap and 12-inch o.c. in
Min. 15/32-inch plywood at two (2), equally spaced, staggered center rows; (Optional) SBS-
W-51 Flintlastic SA NailBase Simplex MAXX Cap
max 24-inch spans SBS-SA 45.0*
P Stress plates shall be primed with FlintPrime SA
(ASTM D41) primer.
W 52
Min. 15/32-inch plywood at
Flintlastic SA NailBase
Min. 1-inch long, 12 ga. Simplex
6-inch o.c. at min. 2-inch lap and 6-inch o.c. in
(Optional) SBS-
max 24-inch spans
p
Metal Cap Nails
four (4), equally spaced, staggered center rows
SA
SBS-SA
52.5
Min. 19/32-inch plywood at
32 ga., 1-5/8-inch dia. tin caps
8-inch o.c. at min. 2-inch lap and 8-inch o.c. in
W-53
max. 24-inch spans
Flintlastic SA NailBase
with 11 ga. annular ring shank
three (3), equally spaced, staggered center
(Optional) SBS-
SBS-SA
-52.5
nails
rows
SA
Min. 19/32-inch plywood at
32 ga., 1-5/8-inch dia. tin caps
8-inch o.c. at min. 2-inch lap and 8-inch o.c. in
W-54
max. 24-inch spans
Flintlastic SA NailBase
with 11 ga. annular ring shank
three (3), equally spaced, staggered center
(Optional) SBS-
SBS-SA
-60.0
nails
rows
SA
8-inch o.c. at min. 3-inch lap and 8-inch o.c. in
W-55
Min. 15/32-inch plywood at
Flintlastic SA NailBase
Simplex MAXX Ca
P P
three (3), equally spaced, staggered center () q Y P gg
(Optional) SBS-
max 24-inch spans
rows; Stress plates shall be primed with
SA
SBS-SA
67.5
FlintPrime (ASTM D41) primer.
W-56
Min. 19/32-inch plywood at
Flintlastic SA NailBase
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
min. 2-inch lap and 6-inch o.c. in
(Optional) SBS-
max 24-inch spans
P
nails
four ( ), e u
four (4), equally spaced, staggered center rows
SA
SBS-SA
-75.0
Cap nails: 1-inch diameter,
Min. 15/32-inch plywood at 0.032-inch thick metal cap with
W 57 Flintlastic SA NailBase
7-inch o.c. at min. 4-inch laps and 7-inch o.c. in
(Optional)SBS-
max 24-inch spans
P 0.120" shank diameter, annular
five (5), equally spaced, staggered center rows
SA
565-SA
75.0
ring shank nails
Min. 19/32-inch plywood at 32 ga., 1-5/8-inch dia. tin caps
W-58 P Flintlastic SA NailBase with 11 ga. annular ring shank
4-inch o.c. at min. 2-inch lap and 4-inch o.c. in
(Optional) SBS-
max 24-inch spans
nails
four (4), equally spaced, staggered center rows
SA
SBS-SA
105.0
'FIYBRID$YStEMS �:.
. -•
as
Glasbase; Plexiglas; Flintlastic
Min. 19/32-inch exterior grade Base All Weather Empire 32 ga., 1-5/8-inch dia. tin caps
W-59 g / P
with 11 ga. annular ring shank
9-inch o.c. at 4 inch lap and 12-inch o c In two
SBS-AA, SBS-TA
at max. 24-inch s ans Base; Poly SMS Base; Ultra Poly
plywood P Y y nails
(2), equally spaced, staggered center rows
SBS-SA-H
or APP-TA
45.0*
SMS Base
Glasbase; Flexiglas; Flintlastic
W-60
Min. 15/32-inch plywood at
Base 20; All Weather / Empire
Min. 1-inch long, 12 ga. Simplex
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
SBS-AA, SBS-TA
max 24-inch spans
P
Base; Poly SMS Base; Ultra Poly
Y Y
Metal Ca Nails
P
(4), equally spaced, staggered center rows
SBS-SA-H
or APP-TA
-52.5
SMS Base
Exterior Research and Design, LLC. d/b/a Trinity) ERD
Evaluation Report 3520.03 04-1120 for FL2533-R39
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017
Prepared by-, Ro ert Lem nen, E_-5916 - - -- - - -- - - - C-ertainTeed Flintlastic® Modified-Bitumen_RoofSystems;(610) 55Li84Z Appendix 1 Page 13 of 57
��TRINITYJERD
1E 1: WOOD DECKS —NEW CONSTRUCTION 'IRE (TEAR-UFFj
SYSTEM TYPE E: NON -INSULATED_ „MEC ANICAUS A�T_FP HE— BaASE SHEET, BONDED ROOF COVER
System Deck Base Sheet
Roof Cover (Note 14)
MDP
No. (Note 1) Base Fasteners Attach
Ply
Cap
(Psf)
W-61
Min. 19/32-inch plywood at
Glasbase; Flexiglas; Flintlastic
Base 20; PolySMS Base; Ultra
32 ga., 1-5/8-inch dia. tin caps
with 11 a. annular ring shank
g g
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
SBS-AA, SBS-TA
max 24-inch spans
P
Poly SMS Base
nails
3 , equally s aced, sta eyed center rows
() P staggered
SBS-SA-H
or APP-TA
-52.5
W-62
Min. 19 32-inch I
/ plywood at
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
SBS-AA, SBS-TA
max 24-inch s ans
P
Poly SMS Base
nails
(3), equally spaced, staggered center rows
SBS-SA-H
or APP-TA
-60.0
W-63
Min.19/32-inch at
plywood
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
6-inch o.c. at 4-inch lap and 6-inch o.c. in four
SBS-AA, SBS-TA
max 24-inch spans
P
Poly SMS Base
nails
(4), equally spaced, staggered center rows
SBS-SA-H
or APP-TA
-82.5
W-64
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
4-inch o.c. at 3-inch lap and 4-inch o.c. in four
SBS-AA, SBS-TA
ns
max 24-inch nch spans
Poly SMS Base
nails
(4), equally spaced, staggered center rows
SBS-SA-H
or APP-TA
-105.0
:CONVENTIONAL
SYSTEMS:,
Glasbase; Flexiglas; Flintlastic
W-65
Min. 19/32-inch exterior grade
Base 20; All Weather /Empire
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
9-inch o.c. at 4-inch lap and 12-inch o.c. in two
BP -AA, SBS-AA,
SBS-AA, SBS-TA
at max. 24-inch spans
plywood P
Base; Poly SMS Base; Ultra Poly
Y Y
nails
(2), equally spaced, staggered center rows
SBS-TA or APP-
or APP-TA
45.0*
SMS Base; Yosemite
TA
W-66
Min. 15/32-inch exterior grade
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather / Empire
Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 18-inch o.c. in two
(Optional) BP-
SBS-AA, SBS-TA
plywood at max. 24-inch spans
Base; Poly SMS Base; Yosemite
(2), equally spaced, staggered center rows
AA. SBS-AA, SBS-
orAPP-TAS
-45.0*
TA or APP-TA
W-67
Min. 15/32-inch exterior grade
plywood at max. 24-inch spans
Flintlastic APP Base T
Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 18-inch o.c. in two
(Optional) APP-
APP-TA
45.0 *
P
(2), equally spaced, staggered center rows
TA
Glasbase; Flexiglas; Flintlastic
W 68
Min. 15/32-inch plywood at
Base 20; All Weather/ Empire
Min. 1-inch long, 12 ga. Simplex
6-inch o.c. at 3-inch lap and 6-inch o.c. in four
(Optional) BP-
SBS-AA, SBS-TA
max 24-inch spans
Base; Poly SMS Base; Ultra Poly
Metal Cap Nails
(4), equally spaced, staggered center rows
AA, SBS-AA, SBS-
or APP-TA
-52.5
SMS Base; Yosemite
TA or APP-TA
W-69
Min. 19/32-inch plywood at
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base; Ultra
32 ga., 1-5/8-inch dia. tin caps
with 11 ga. annular ring shank
8-inch o.c, at 4-inch lap and 8-inch o.c. in three
BP -AA, SBS-AA,
SBS-AA, SBS-TA
max 24-inch spans
Poly SMS Base; Yosemite
(3) , equally spaced, staggered center rows
SBS-TA orAPP-
or APP-TA
52.5
nails
TA
W-70
Min. 15/32-inch exterior grade
Glasbase; Flexiglas; Flintlastic
Base 20; All Weather /Empire
Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 12-inch o.c. in two
(Optional)
SBS-AA, SBS-TA
plywood at max. 24-inch spans
Base; Poly SMS Base; Yosemite
(2). equally spaced, staggered center rows
AA, SBS-AA, SBS-
, S
or APP-TA
-52.5
TA or APP-TA
W 71
Min. 15/32-inch exterior grade
I wood at max. 24-inch s
Flintlastic APP Base T
Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 12-inch o.c. in two
(Optional) APP-
APP-TA
52.5
P Y P ans
(2), equallyspaced, staggered center rows
TA
W 72
Min. 19/32-inch plywood at
Glasbase; Flexiglas; Flintlastic
Base 20; PolySMS Base; Ultra
32 ga., 1-5/8-inch dia. tin caps
with 11 a. annular ring shank
g
8-inch o.c. at 4-inch lap and 8-inch o.c. in three
BP -AA, SBS-AA,
SBS-AA, SBS-TA
max 24-inch spans
P
Poly SMS Base; Yosemite
g
nails
3 , equally s aced, sta ered center rows
() P staggered
SBS-TA or APP-
or APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity( ERD
Certificate of Authorization #9503
. Prepared by: Robert
Evaluation Report 3520.03.04-1120 for FL2533-1139
O EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017
hFlintlastic®-Modified-Bitumen-Roof-Systems;-(610)-653,5847 Appendix 1, Page 14 of 57