Loading...
HomeMy WebLinkAboutNOAl SCANNED IAMd•C1►D g' 8-IL II^.LUi Ctt3l�"Ylfi�� MIAMI-DADS COUNTY PRODUCT CONTROL SECTION :PARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 )ARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 OTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy I Roofing, LLC Irvine Center Drive, Suite 100 e, CA 92618 COPE: his NOA is being issued under the applicable rules and regulations governing the use of construction materials. The )cumentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be ;ed in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). his NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. m This NOA renews NOA No. 13-0723.05 and consists of pages 1 through 8. 10 a� SO The submitted documentation was reviewed by Alex Tigera. FILECOPY •DADE COUNTY NOA No.: 16-0711.05 MIAMI' Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 1 of 8 ASSEMBLY APPROVAL Roofing Roofing Tiles Concrete Wood SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. PRODUCT DESCRIPTION nufactured by Test Product Applicant Dimensions Specifications Description ny 900-Slate Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-5/32" batten, mortar set or adhesive set applications. ny 900 Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Shake Width = '13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush ny 900-Shake Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete roof Width: varies pieces for use at hips, ridges and rakes. varying thickness NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 2 of 8 1 MANUFACTURING LOCATION Lake Wales, FL EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied 94-084 Static Uplift Testing May 1994 neering, Inc. TAS 101 (Mortar Set) Center for Applied 94-060A Static Uplift Testing March, 1994 neering, Inc. TAS 101 (Adhesive Set) Center for Applied 25-7183-6 Static Uplift Testing TAS 102 Feb. 1995 neering, Inc. (2 Quik-Drive Screws, Direct Deck) Center for Applied 25-7183-5 Static Uplift Testing TAS 102 Feb. 1995 neering, Inc. (2 Quik-Drive Screws, Battens) Center for Applied 25-7214-1 Static Uplift Testing TAS 102 March, 1995 .neering, Inc. (1 Quik-Drive Screw, Direct Deck) Center for Applied 25-7214-5 Static Uplift Testing TAS 102 March, 1995 .neering, Inc. (1 Quik-Drive Screw, Battens) Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 neering. Inc. Test #MDC-77 TAS 100 edland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II &III TAS 108 (Nail -On) edland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) edland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) edland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails tlanta Testing & R1.894/R2.894/R3.894 Physical Properties Aug. 1994 ngineering, Inc. TAS 112 elotex Corporation 520109-1 Static Uplift Testing Dec. 1998 esting Service 520111-4 TAS 101 elotex Corporation 520191-1 Static Uplift Testing March 1999 estina Service TAS 101 alker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 alker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 alker Engineering, Inc. Evaluation Calculations 25-7584/25-7804b-8/25-7804-4 & 5 December 1996 25-7848-6 alker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 alker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 alker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 alker Engineering, Inc. Evaluation Calculations Restoring Moments Due to Gravity 09/01/16 nerican Test Lab of RT0617.04-16 TAS 112 06/29/16 ,uth Florida NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 3 of 8 LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofmg Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length-1 (ft) Width-w (ft) Slate, xony 900 Shake & Split Shake 10.9 1.417 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile A, (ft3) 2, (ft3) Profile Batten Application Direct Deck Application axony 900 0.291 0.315 late, Shake & Split Shake Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Saxony 900 late, Shake & Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck lit Shake 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 4 of 8 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile 11 Profile I' Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens S xony 900 2=10d Ring Shank Nails 30.9 38.1 17.2 Si ate, Shake & Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Sf ake 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance xony 900 Slate, Shake & Split Shake Adhesive' 31.3z & 3 1 Ii See foam adhesive manufacturer's component approval for installation requirements. 211 3 The Dow Chemical Company TileBond'T' one -component foam minimum weight per paddy 13.9 grams. ICP Adhesives Polyset@ AH-160 two -component foam, minimum weight per paddy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance S xony 900 Slate, Shake & Split Shake ICP Adhesives Polyset® AH-160 Two -component foam 118.94 40.45 311 Large paddy placement of 45 grams of Polyset® AH-160. 4' Medium paddy placement of 24 grams of Polyset® AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems f Tile Profile Tile Application Minimum Attachment Resistance axony 900 Slate, Shake & Split Shake Mortar Seth 43.96 Tile-Tite Roof Tile Mortar • NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 5 of 8 "'% . LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT) LOCATED UNDERNEATH TILE BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. HOLES V PROFILE DRAWINGS UNDERLOCK I SAXONY 900 - SLATE 5/32" (Slate) COVERLOCK NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 6 of 8 PROFILE DRAWINGS NAIL 10LES w l'�� ote: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush SAXONY 900 - SPLIT SHAKE 1-9/32" (Shake) NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 7 of 8 NAIL HOLES rR PROFILE DRAWINGS SAXONY 900- SHAKE END OF THIS ACCEPTANCE 1-9/32" (Shake) NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 8 of 8