Loading...
HomeMy WebLinkAboutENGINEERING SUBMITTALSSCANNED ENGINEERING SUBMITTALS BY St. Lucie County June 6, 2018 WIND LOAD CERTIFICATION: CODE FBC 2017 6TH ADDITION/ FRC 2017/ ASCE WIND SPEED: 170 mph, 3 SEC. GUST EXPOSURE: "D" IMPORTANCE FACTOR: 1.0 INTERNAL PRESSURE COEFF.: 0.00 JOB: BAKER RESIDENCE 367 NETTLES BLVD. JENSEN BEACH, FL RECEIVED JUN 2 6 1818 Permitting Department St. Lucie County 10 ST. LUCIE COUNTY BUILDING DIV'ISIO REVIEWED FOR COMP NC REVIEWED BY DATE to 11c, PLANS AND PER IT MUST BE KEPT ON/JOB OR NO INSPECTION W114 BE MADE MIN. SET13ACvREQ. FRONT // e � N THESE PLANS AND ALL PROPOSED 11JORf1 ARE SUBJECT TO ANY C'OiRECTIONS REQUIRED liy FRU INSKO'i ORS TNAT UIY ®E NECESSARY IN ORDER TO , COMFU V11TH ALL APPLICAOI E CODES, COMM FASTENERS OR A77ACHMEM PAUL WELCH INC. ARE THE RESPONSIBILITY OF THE Mechanical Electrical Civil Engineering CONTRACTOR OF RECORD 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email — pwelchincr&aol com FILE Gv_ MPY Paul Welch, P.E. Fla Reg. No. 29945 i Do Z y PAUL WELCH INC. MECH-ELECT-CIVIL ENG. 1984 BILTMORE ST. #114 PORT SAINT LUCIE, FL 34984 PAUL WELCH R.E. FLA REG NO.29945 JUN 0 6 2018 tj4LNO)N z INDIAN RIVER LAGOON z #1500 PWC LIFT t` LADDER AFFIXED W (4)Y' x 5' SS LAC, BOLTS ,.._.._.._.._.._._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.:...... ...... _.._ \ PROPERTYLINE 34.64' SHORELINE To`\ NETTLES ISLAND INC, A CONDO - SECTION II PARCEL 367N .1ENSEN BEACH MANGROVE CANOPY • L U��Ju.iv`n ZJ_p_LL�Q •Z > L T =-N UVLIJ-f J12- Jz LUri�l1J "+ j FLU ;LuI� <=M<Z5 lLuco�a u. a: r0,. a Dock Section Thru All Bolts 518" S.S. w Washers & Nuts t' X 4' THRUFLOI .king. Fasten w #' 3 (304) Screws, 2 Stringer xB,SYP,.40CC orACQ treated `ringers, lap splice x 8 , SYP, .40 CC •ACQ treated ben 8" Dia. CCA treated piles Pilings jetted to a minimum depth of Wand as necessary to provide adequate bearing and stability BAKER .1ENSEN BEACH Dock Plan View ~— 4' - 10' Center Stringer(s) toe Nailed w SS Ring Shank Nails, Outside Stringers Face Nailed Jerner&Associates, Inc. Marine & Environmental Consulting 2537SE Alfonso Ave, Port St. Lucie,FL34952 PIE(772)2832950 JERNER@BELLSOUTH.NET N cfl co co —cQ 2' O. C. Max. U w � -j ui v Z.J�'- LL�� Each Way �— LLI=N �U��UO tvv0 Jw� LU WJZ�OC nQ LLJ CO �To o_ Decking Secured with #10 head S.S. Screws 2 Per Stringer Date. 412118 SHEET 4 W 19—im RECEIVED JU4,16 2013 Permitting'Depal tment St. Lucie COU ItY 21-3/4" 112' THROUGH BOLTS 3 9/160 OO DOCKR ANCHORS T PLACES NOT SUPPLIED 12 — &w 82-3/4' -UM NON SKID STEPS 1&X2'wXI/8' EXTRUDED CHAN. 12'TYP. 5 PLACES 61' SCHEDULE 40 ALUMINUM TUBING 19—iff International Dock Products Inc. STEP STRAIGHT LADDER 954-964-5315 Fax:9-54-964-2715, P AUL WELCH INC. MECH-ELECT-CIVIL ENG. 1984 BILTMORE ST. #114 PORT SAINT L UCIE, FL 34984 PAUL WELCH R.E. FLA REG NO.29945 JUN 0 6 2018