Loading...
HomeMy WebLinkAboutENGINEERING` �ONTI2ACTOR: TRI-COUNTY ALUNE NUD ` -"T. WIND SPEED AND EXPOSUnT 7AVE DESIGN CRITERIA: BEEN DETERMINED USING -. ADVANCED TECHNOLOGY COUNCIL'S WzJ3STTE Applicable Codes. Regulations, and Standards AND GOOGLE EARTH. 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADMI Specifications for Aluminum Structures, Part 1-A ofthe Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load 2 PSF 3. Wind Load- 1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Basic Wind Speed, Figure 1609.3(3), State of Florida Debris Region & Basic Wind Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Sp Vura =150 MPH. VASE) =116 MPH 3.3. Exposure Category, Section 1609A.3: Exposure B 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1- Patio Cover: Non -Habitable, Unconditioned Roof Type 1..Roof Type: MONOSLOPE 2. Roof Material: 3" x 12" x 0.019" Four Seasons Building Products Steel Rhino Panel, Florida Product Approval Number FL 18464-R1. Foundation Design Existing concrete. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 TS Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: c i. Portland Cement Type 1,- ASTM C 150 1 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 'iii. Air entraining +/-1% - ASTM C 260 iv.Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM Al85 c. Concrete slump at discharge chute not less than 3" or more than 5". Water. added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. IL All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Use of these plans acknowledges and accepts a limit of liability not to exceed design _ —and-engineering-f - -- - -- - - - - - - - - - - - - - - - - - - SCANNED BY St. Lucie Goi:tritty 9'-01 9'-0. 12'-0" 3X3X0.125 ui rai 0LLJ a a o LL Z La W W Q m W m W W Z 0 Z 0z Qz Z =� OU W 1- LL oC LL DRAWN BY GD DATE DRAWN 02/17/18 REVISION SHEET NO: Nl A-1 ALUNIINUM MEMBERS DIMENSIONS �� `• � � ��11i flllJl HOLLOW SECTIONS 2x2:2"x2"x0.046" 2x3: 2"x3"x0.050" 2x4: 2"x4"x0.050" #14x3K'SMSW/ 2x5: 2"x5"x0.050" NEOPRENE FACED �'� dam' O OPEN BACK SECTIONS WASHER @ 4" O.C. � o N z co r Q 1x2: 1"x2"x0.040" Q-. V o 1 x3: 1"x3"x0.045" SNAP SECTIONS 2x2Snap: 2"x2"x0.0451, 0�- - 2 x 3 Snap: 2" x 3" x 0.050" � 2 x 4 Snap: 2" x 4" x 0.045 I 3" x 3"POST • ��/ P� `�i i 3" x 12" RHINO / b1 qIQryAL�SEAL L PAN PANEL • SELF MATING (SMB) C 2x4SMB 2"x4"x0.044"x0.100" ' ! 'I • 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 3/8" DIA THRU BOLTS ❑ Q 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" (2) 3/8" DIA CONCRETE I ! (4) TOTAL • 2' x 8 SCREWANCHORS �• SMB 2 x 7 SMB: 2" x 7" x 0.057" x 0.120" 2 x 8 SMB: 2" x 8" x 0.072" x 0.124" (3" CONC. EMBED) E INTERN 1/8" E ER EXTRUDED • 0 ui W 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" I I 3" x 3" x 1/e" EXTRUDED 2" x 5^ SMB V a a 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" I POST BASE W/ (2) 3/8" • W z DIA THRU BOLTS 3" x 3" x 0.090" " LL POST LL Z W m z MINIMUM FASTENER EDGE DISTANCE: 1/2" O v C f! z MINIMUM FASTENER SPACING. 3/4" 1 11 . x 21/8" x 1 1/2" x 8" x 0.062"ALUM a m Lu m a a: !' ,•e RECENING CHANNEL W/ (7) W G, g CONCRETE SCREW ANCHOR: $ a_ #14 x 3l4" SMS EACH SIDE OF W (A z p z z SIMPSON TTTEN HD OR EQUIVALENT' BEAM & (4) 318" DIA THRU BOLTS Z Q N N �z Qz SHEET METAL SCREWS (SMS): ;" .a ; 6' " a., Y INTO POST U� O u Z u ITW / BUILDEX OR EQUIVALENT �. :.o W I-- i 0 u' a CC z G a a S HINO PAN ROOF TO POST CONNECTION i B 3" x 3" POST TO CONCRETE CONNECTION DETAIL n SCALE: NTS Z U c A-2 SCALE: NTS A-2 J G a N •i L= CL $Q k N ��5 S c: a W W�CP W 3 W "'mm Z = Z�: UPu J Z^^ Cj7'^3^^ a E J Z OR s f' N W s 3 a - a #14 x 3/4" SMS W/ Z NEOPRENE FACED FLASHING WASHER @ 4" O.C. #14 x 3/4" SMS W/ a NEOPRENE FACED FLASHING #14 x 3/4" SMS W/ LL WASHER @ 4" O.C. NEOPRENE FACED PANIPANE WO C 3" RHINO PANEL WASHER @ 4" O.C. 3 3" RHINO PANEL c I I N w LL c/9 0 'c W U a U a LL • EXISTING • • Q Z U C • _ £ BUILDING • EXISTINGF I Ij I � • `s - J � J 2"x8"SMB •_ • ! II 2"x6"SMB V M C CROSSBEAM • 2" x 6" SMB • BUILDING • END BEAM W m C,4 z END BEAM 1 I! • { Z Z5 F- O z c, • i • I I a: ID(LL _ E 1 2"x5"SMB -- - — _ _ _ __ _ -__ _ _ -- --- 3"x3"x0.090" 1 1/2"x21/8"x11/2"x6"x0.062"ALUM DRAWN BY POST 1 I RECEIVING CHANNEL W/ (5) GD I — - --ALUM RECEIVING CHANNEL i #14 x 3/4" SMS EACH SIDE OF 21/8�d_1/2"x-0 06 '— — — - — W/ (5) #12 x 3/4"SMS EACH I I I 2" x S' SMB ( BEAM 8 (3) 3/8"DIA THRU BOLTS DATE DRAWN /CWM RECEIVING CHANNEL _ _ ! SIDE OF BEAM & (3) 3/8" DIA. I INTO POST 02/17/18 W/ (O BE12 AM 3/4" SMS EACH 2" x 5" SMB THRU BOLTS INTO THE POST 3" x 3" x 0.126' SIDE OF BEAM & (4) 3/8" DW. � THRU BOLTS INTO THE POST POST REVISION 3" x 3" x 0.126' 1 - POST S-, HINO PANEL TO CORNER POST IM 4TH WALL DETAIL S-3 RHINO PANEL TO CORNER POST CONNECTION 0 SCALE: NTS 3 A-2 S-2 HINO PANEL TO CORNER POST 4TH WALL DETAIL scALE: NTs A-2 SCALE: NTS A-2 SHEET NO: A-2 1 1 /2" x 21/8" x 1 1/2" x 0.062" BEAM DEPTH CHANNEL W/ (4) #14 x 3/4" SMS INTO BEAM EACH SIDE & (4) #14 x 3/4" SMS INTO CROSS / END BEAM 1 1/2" x 21/8" x 1 1/2" x 0.062" BEAM DEPTH CHANNEL W/ (4) #14 x 3/4" SMS INTO BEAM EACH SIDE & (4) #14 x 3/4" SMS INTO CROSS / END BEAM • • 2"x5"SMB • 2" x 8" SMB CROSS BEAM OR 2" x 6" SMB END BEAM S-4 INT BEAM TO CROSS./ END BEAM ATTACHMENT A-3 SCALE: NTS `���11{ill►�� 0 to Q • Z= I �,�Qy •• .... �a <1 ,��PROFESSIALSEAL\�\ F L 3" RHINO PAN ROOF PANEL SELF -MATING BEAM • • • 2" x 3" KNEE BRACE -- 1 112" x 21/8"x 1 1W x 0.062" x 2" LONG ALUM RECEIVING CHANNEL W/ (3) #12 x 3/4" SMS EA. FACE & (3) #12 x 3/4" INTO POST S-5 KNEE BRACE CONNECTION DETAIL A-3 SCALE: NTS 4] ❑ L CC CC w Li �- U °' a C LJ I ce �Z � C3 a LL LL- D: N Z W °� ? Oin L Q W W W Z 661 J m LL a 2 W z p z z Z N Jy mZ aZ - Ou Zu 'a Z 20 O� u W F- OC ri a C C Z uu M c Z .a c U 0 a J 7 an n u � ,n � Q � o as k Vi � lumgod S 'o a Lu q W3 "AA z W j C u U Z U F IbaNN F Z Q :3Z� � 9 NW,�u"LL u - N 0 W � CC U O 0 zw— Q ozU � Jg� mOHN Z CD Z 0 z � M Gam. co a. LL DATE DRAWN 02/17/18 REVISION L - n _ SHEET NO: A-3