Ps outlined in the Florida Building Code, Extreme Metal Fabricators, LLC will accept the installation of metal
roofing panels over one layer of asphaltic shingles or modified bituminous roofing, assuming all requirements
of the 2017 Florida Building Code Sixth Edition, all of Chapter 15, specifically Section1511 Existing Roofing,
and/or 2017 Florida Building Code- Residential Sixth Edition, all of Chapter 9, specfcally Section 905.10 and
Rerootina Section 908 have been met.
It is important to ensure the existing substrate is not deteriorated, there is no entrapped moisture, meets all
code requirements, and to install an approved separator underlayment between the existing roofing and the
metal panels, such as those that comply with ASTM D226 Type I or Type II or ASTM D 1970, or ASTM D
4869. The roofing contractor of record must verify the aforementioned requirements. Having confirmed code
requirements, installation in this manner is approved by Extreme Metal Fabricators, LLC as the manufacturer.
Plywood sheathing must be minimum 15/32" CDX plywood or 3/4" wood plank, solid decking, fastened per FBC
requirements. The wood substrate must be inspected.to ensure that it has not deteriorated and is acceptable
as a suitable substrate for additional roofing, and is attached structurally per current codes. Fasteners used for
metal roofing should penetrate minimum'/4" through structural decking or a .minimum of 1" penetration into a
thicker wood substrate, to insure pull-out values remain the same.
Consideration should be given to the unevenness of the underlying shingles, which may telegraph through the
new metal panels. As in all metal roofing, "oil canning" is an inherent condition that can occur in the panels.
Care should be taken during the installation, to observe the metal panels as they are installed, and adjust
installation procedures, if possible, to help to minimize "oil canning". "Oil Canning" is an aesthetic issue not a
structural issue, and not a cause for rejection.
The energy savings that is normally observed after a new metal roof replaces the previously shingled roof,
which has been documented to account for 20% - 29% savings, may be negated due to the underlying.
shingles holding heat energy much longer than a metal panel installed without shingles beneath it.
It is important to comply with all requirements of the Florida Building Code, Fire Rating requirements, and local
code requirements. As always, authorities having jurisdiction, (building department) should be consulted, and
approve your demolition and reroof installation methods, prior to beginning work.
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
COMPLY WITHSALLRAPPLICABLE CODES.
FILE COPY
Extreme Metal Fabricators, LLC
2160 SW Poma Drive Palm City, FL 34990 & (772) 223-4055 (Phone)
KEYSTONE
(772)781-7492 (Fax)
' , APPxQiED
meets the requirements of ASTM D 6222, Type 1, Grade G
Features and Components
APPeX 4.5M is used as a cap or flashing sheet in APP multi -ply
roofing systems.
Ceramic -Coated Roofing Granules: Specifically engineered for
optimal embedment in the APP-blended sheet The ceramic coating
promotes excellent long-term adhesion.
APP (Atactic Polypropylene) Polymer and Asphalt gland:
Provides an extremely durable sheet with excellentweathering
characteristics, flexibility and dimensional stability for ease of
handling and quick installations.
Polyester Reinforcement Mat Provides bidirectional glass -scrim
reinforcement and offers robust tear strength and puncture
resistance, allowing for high wind performance and excellent
hail rating, The sheet also exhibits strong dimensional stability
and enhanced. elongation.
Polyofefin Burn -Off film: Promotes ease of heat welding
Ceramic•coated
` _
Roofmg Granules
ry'
y'4 J C� j � � ;''J•�:
1�,� fir, iM1�
�',y�:e•
sheet
APP
j
FL
Muddiedf°
:...:_ GlassScrim-Reinforced
;' Flashna_
AsphaR
_
- Polyester Mat
Polyolefin
Bum -off Film
Colors: White, Black, Tan, Brown, Grey, Terra Cotta,
Weathered Wood, Chestnut; Burnt Sienna, Red, and Slate.
System Compatibility 7hispmductmaybeused asacamponerrtinMeIbWngs7yW& Please reference prodectapprrcaffanlorspecificinstallationmethadsandinkmiation.
yy�g� R il.'wl t l I t 5 4 fi - Y
' f"N r ` '✓✓ �, i x st'tt l •.,l
e.�. L L..
Corn bble with die selectedMuhi-plysystems above '
- Do not use in Angle Plysystems �
Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Seff Adhered MF = Mechanically fastened FA = FUlly Adhered BA = Ballasted
Energy and the Environment
I
t..
Inidal
3-yearAed
Reln!!IY'4(ASTMC 1519), Mi rq r
026
027
fAST1(A:C li{7t) "'t o t .
0.87
0M
So1Refectepce,Index*{SRII; EI9aD`
2525
Pre c�iis anefRecj�CTed Contie tL ' F ,
Oy
=Pgst consUtnertiecjrcledColitiiiitt, t _k
0%
P�eeya�k�Advantage® Guarantee Information
a Garen
tee;Temt
Dependenton system* I Up to20years
ToMactNTechnicalServicesforspecific system requiremetdsorguaranteetems.
Codes and Approvals
., 'bsry�o
COUS r o.a. comp
a►eovEo ►.muawow��pwomd
UL Class A ratings may be obtained in numerous constructions,
both new and re -roof at slopes up to 1' per foot 183 mm/m).
Refer to the Safe Use Instructions and product label prior to using this product
The Safe Use Instructions are available by calling 1800) 922-BM or on the Web at
www.im.com/ronfing.
Product Application
HeatWeld
Referto JM APP modified bitumen specifications and detail drawings
for application and slope information.
Packaging and Dimensions
Rall dth k
39 W 0 m)
RotttengthN ` ' ,_
32' 10'(10.01 in)I)clt'Cdvera
e`
95.8 ff (8.9 m?)
Rc1llNel
112lb (50.8 kg)
p�rPaAet
(tolLa25
3Pall�ts 'er�tricl�'* .
16
mQumes a g sme iap.
**Assumes a 48' flatbed truck.
RS4M 3-16(Replaces9-14)
Meets the requirements of ASTM D 6222, Type I, Grade G
Tested Physical Properties
ASTM
Standard for ASTM D Yi/
Physical op
��
Tear Resistance ® 7W F
D 4073 / 5147
z 701bf
1141bf 85 lbf
1 Peak Load at0°F(-18°C)
D5147
z601bffin-width
1331bffin-width
107lbffin-width
Peak Load at73.4°F (23°C)
Unconditioned
D 5147
z 50 Ibff n-width
83 Ibf(n-width
63 lbffin-width
90-Day Heat Conditioned
D 5147 / 5869
z 50 Ibffin-width
102lbf1in-width
67 Ibffin-width
Low Temp.Fle)abilo
Unconditioned
D5147
Pass @3z°Frume of the
Pass
®180° F Mandrel (Pass -Fail)
90-Day Heat Conditioned
D 5147/ 5869
specimens show cracidng•
Pass
LowTemperature Unrolling (Pass -Fail) Unroll in 4 6s;
"unrolled°
D 5636
Pass®41° F'none afthe
Pass
-'
Visual Inspection in position
specimensshowcracldng'
t
o
Compound Stability - 2 hr 15 min ® 230 F (Pass -Fail)
D 5147
Pass'nofailures showing signs of
flawing, dripping, or drop formation
Pass
Granule Loss
D 4977/5147
2 g (0.07 oz)
1.8 g (0.06 oz)
Thickness
D 5147
z 160 mils
160 mils
m
or
Bottom Coating Thickness
D 5147
2 30 mils
53 mils
Water Absorption- water by distillation
D5147/95
02%
0.6%
,.<
Moisture Content distillation
Y
D5147/95
51 %
02%
`-
Ultimate Elongation at 73.4°F (-18°C)
D 6222
t 30 %
53%
62%
X'r Y
Elongation at Peak Load ® 0° F
D 5147
z 10 %
12%
10%
x
Unconditioned
05147
z 23 %
51 %
59%
Elongation at Peak Load ®74.4° F 90-Day Heat Conditioned
D 5147/ 5869
z 23 %
41 %
32%
Dimensional Stability - 24 hr @ 176° F
D 5147 / 1204
s 1 %
0.20%
0.10%
Net Mass per UnitArea
D146
A511J/100ftl
97lb/100ftz
*MD =Machine Direction
**XMD = Cross -Machine Direction
Note: All data represents tested values.
Refer to the Safe Use Instructions and product label prior to using this product
The Safe Use Instructions are available by calling (800) 922-5922 or on the Web at
wvvw.im.com/roofing.
RS-43g2 3-161Replaces S-14)
U
iJ
SECTION1507
REQUIREMENTS FOR ROOF
COVERINGS
1507.1 Scope.
Roof coverings shall be applied in accordance with the applicable provisions of this section and
the manufacturer's installation instructions.
1507.1.1 Un+derlayment.
Unless otherwise noted, underlayment for asphalt shingles, metal roof panels, metal roof
shingles, mineral surfaced roll roofing, slate shingles, wood shingles, and wood shakes shall
conform to the applicable standards listed in this chapter. Underlayment materials required to
comply with ASTM D226, D1970, D4869 and D6757 shall bear a label indicating compliance to
the standard designation and, if applicable, type classification indicated in Table 1507.1.1.
Underlayment shall be applied and attached in accordance with Table 1507.1.1.
Exception: A reinforced synthetic underlayment that is approved as an alternative to
underlayment complying with ASTM D226 Type II and having a minimum tear strength per
ASTM D1970 or ASTM D4533 of 20 pounds (9.1 kg) shall be permitted. This underlayment
shall be installed and attached in accordance with the underlayment attachment methods of Table
1507.1.1 for the applicable roof covering and slope, except metal cap nails shall be required
where the ultimate design wind speed, V,lt, equals or exceeds 150 mph.
UNDERLAYMENT TABLE
Roof Covering
Roof Slope 2:12 and Underlayment
Section
Less Than 4:12 Attachments
Un layment
ASTM'b226 e I or
Asphalt
4869 e
Type 1
shingles 1507.2
II, III or IV ASTM
D6757
Concrete and
Clay Tile
1507.3
ASTM D1970
Roof Slope 4:12 and Underlayment
Greater Attachments
Underlayment
ASTM D226 Type II
ASTM D4869 Type 2
IV ASTM D6757
ASTM D1970 3
See Section 1507.3.3
U
ASTM D226 Type I or
Metal roof II ASTM D4869 Type
panels 1507.4 H, III or IV ASTM
D6757
ASTM D1970
ASTM D226 Type I or
Metal roof II ASTM D4869 Type
shingles roofing II, III or IV ASTM
1507.5 D6757
ASTM D1970
ASTM D226 Type I or
Mineral-
II ASTM D4869 Type
surfaced roll
II, 111 or IV ASTM
roofing 1507.6
D6757
ASTM D1970
ASTM D226 Type I or
II ASTM D4869 Type
Slate shingles
II, III or IV ASTM
1507.7
D6757
ASTM D1970
Wood shingles ASTM D226 Type I or
1507.8 II ASTM D4869 Type
II, III or IV
Wood shakes
1507.9
ASTM D226 Type I or
Photovoltaic II ASTM D4869 Type
Shingles II, III or IV ASTM
1507.17 D6757
ASTM D1970
aUnderlayment Attachment
ASTM D226 Type II
1 ASTM D4869 Type
IV ASTM D6757
2
3 ASTM D1970 .3
ASTM D226 Type II
1 ASTM D4869 Type
IV ASTM D6757
2
3 ASTM D1970 3
ASTM D226 Type II
1 ASTM D4869 Type
IV ASTM D6757
2
3
ASTM D1970 3
ASTM D226 Type II
1
ASTM D4869 Type 2
IV ASTM D6757
3
ASTM D1970 3
ASTM D226 Type II
1
ASTM D4869 Type 2
IV
Limited to roof
ASTM D226 Type II
slopes 4:12 and
ASTM D4869 Type 2
Greater
IV
ASTM D226 Type II
1 ASTM D4869 Type .2
IV ASTM D6757
3 ASTM D1970 3
1. 1.Roof slopes from two units vertical in 12 units horizontal (I7-percentslope), and less
than four units vertical in 12 units horizontal (33-percent slope). Apply a 19-inch (483
mm) strip of underlayment felt parallel to and starting at the eaves, fastened sufficiently
to hold in place. Starting at the eave, apply 36-inchwide (914 mm) sheets of
underlayment, overlapping successive sheets 19 inches (483 mm), end laps shall be 6
inches and shall be offset by 6 feet. The underlayment shall be attached to a nailable deck
with corrosion -resistant fasteners with one row centered in the field of the sheet with a
maximum fastener spacing of 12 inches (305 mm) o.c., and one row at the end and side
laps fastened 6 inches (152 mm) o.c. Underlayment shall be attached using metal or
plastic cap nails with a nominal cap diameter of not less than 1 inch. Metal caps shall
have a thickness of not less than 32-gage sheet metal. Power -driven metal caps shall have
a minimum thickness of 0.010 inch. Minimum thickness of the outside edge of plastic
caps shall be 0.035 inch. The cap nail shank shall be not less than 0.083 inch for ring
shank cap nails and 0.091 inch for smooth shank cap nails. Cap nail shank shall have a
length sufficient to penetrate through the roof sheathing or not less than 3/4 inch into the
roof sheathing.
2. 2.Roof slopes of four units vertical in 12 units horizontal (33-percent slope) or greater.
Underlayment shall be applied shingle fashion, parallel to and starting from the eave and
lapped 4 inches (51 mm), end laps shall be 6 inches and shall be offset by 6 feet. The
underlayment shall be attached to a nailable deck with two staggered rows in the field of
the sheet with a maximum fastener spacing of 12 inches (305 mm) o.c., and one row at
the end and side laps fastened 6 inches (152 mm) o.c. Underlayment shall be attached
using metal or plastic cap nails with a nominal cap diameter of not less than 1 inch. Metal
caps shall have a thickness of not less than 32-gage sheet metal. Power -driven metal caps
shall have a minimum thickness of 0.010 inch. Minimum thickness of the outside edge of
plastic caps shall be 0.035 inch. The cap nail shank shall be not less than 0.083 inch for
ring shank cap nails and 0.091 inch for smooth shank cap nails. Cap nail shank shall have
a length sufficient to penetrate through the roof sheathing or not less than 3/4 inch into the
roof sheathing.
3. 3.Roof slopes from two units vertical in 12 units horizontal (17-percent slope), and
greater. The entire roof deck shall be covered with an approved self -adhering polymer
modified bitumen underlayment complying with ASTM D 1970 installed in accordance
with both the underlayment manufacturer's and roof covering manufacturer's installation
instructions for the deck material, roof ventilation configuration and climate exposure for
the roof covering to be installed.
Exception: A minimum 4-inch-wide (102 mm) strip of self -adhering polymer -modified
bitumen membrane complying with ASTM D 1970, installed in accordance with the
manufacturer's instructions for the deck material, shall be applied over all joints in the
roof decking. An approved underlayment in accordance with Table 1507.1.1 for the
applicable roof covering shall be applied over the entire roof over the 4-inch-wide (102
mm) membrane strips.