Loading...
HomeMy WebLinkAboutSURVEY(4�0i'UALED ARE THE RFSPONRIAII [TV n; TWg THFAF DI AMQ AM) Al I n0MMf-,CM 1XIAMV ST. LITUE UOL�TY LRUI %AWST BE KEPT ON JOB WILL BE ILAD-1- E. U) ljo U) Z UJ o R z� <w 0z": U) U 2 N 1402 i?a 47, tort 'pf 49., j PALMERI & jerner &Associates, Inc. SHEET I AMarine & Environmental Consulting Date: 615118 53 NETTLES BLVD. 2537SEAlfonsoAve Port St. Lucie, FL 34952 Ph.(772)283-2950 1EASEN B-A54 CH JERNER@BELLSOUTH.NET y IN&W MER LAGOON NO PORTION OF DOCK STRUCTURE OR ELECTRIC TO BE AFFIXED TO SEAWALL UMMMUN ... C\1 &d� ...... ...... 12'6" ...... ...... ...... ................................ APPROX. RIPARIAN LINE PALMERI 53 NET TL ES BL VD, Hl�-AU- --- jt Z M Co Ln Ao 0 :70 00 i D5, in : CJI 0 0 P.E. # 7245-1- 1402 Ha 'A, 6a,r- i11 ; Fort Ple 6,T�1349 V"= 10/ jerner &Associates, Inc. Marine & Environmental Consulting Date: 615118 2537 SE Alfonso Ave. Port St. Lucie, FL34952 PIL(772)283,2950 JERNER@BELLSOUTH.NET SHEET Dock Section Thru Pilings jetted to a minimum depth of 6' and as necessary to provide adequate bearing and stability PALMERI 53 NETTLES BL VD, - _ -------.1�NSEl--V BEAC'f_-- Bolts 5/8" S.S. w Washers & Nuts X 4' THRUFLOW king. Fasten w #10 3" (304) Screws, 2 per Stringer x 8 , SYP, .40 CCA or ACQ treated ringers, lap spliced x8;SYP,.40CCA ACQ treated bents 8" Dia. CCA treated piles Design Windload Information Code: FBC 2017 6TH ADD/ FRC 2017/ ASCE 7-10 Wind Speed: 170 MPH, 3 Second Gust Exposure D" Importance Factor. • 1.0 Internal Pressure Coeff,: 0.00 Height: <10 Ft. Mean Dock Plan Vie Dande' ai eYh W61 P.E751 , ,6 pa oad 4'— 10' For€P. "rrk� !fie, FL`34�47 ..... Jerner & Associates, Inc. Marine & Environmental Consulting 2537SEAlfonso Ave Port St. Lucie,FL34952 Ph.(772)283-2950 12' O.C. Max. Each Way Grated Decking Secured with #10 Pan head S.S. Screws 2 Per Stringer - CENTER STRINGERS TIED DOWN WITH 2"X 4" X 12" 0.40 TREATED PINE W 2PC 3" SS SCREWS @ EA MEMBER Date: 615118 SHEET 3 tr e + � — 01.45rl,— COA 74�0 LA00 R S7010 Ri.d l"f1R;f (i,¢ SE A1A Dock Products, Inc 5745 Plunkett St. Hollywood, FL 33023 Lift Ladder Law's Electrical Service Inc. 5158 NW Primm St Pt St Lucie FI.34983 11 Pcl fAn( A /i 1 /' /') ENGINEERING REVIEW. BOAT LIFT TOP CARRIER BEAMS AND MOUNTING BRACKETS COMPLY WITH WIND LOAD REQUIREMENTS OF THE 6TH EDITION (2017) FLORIDA BUILDING CODE, PER ASCE 7, AND PER DESIGN LOAD REQUIREMENTS OF THE 2015 EDITION ALUMINUM ASSOCIATI^Al'C ALUMINUM DESIGN MANI BEAMS AND MOUNTING BRAC INSTALLED PER HI-77DE INSTRUC770N_' EXCEED ULTIMATE DESIGN WIND SPE 180 MPH (EXPOSURE CATEGORY C BOA7S ARE TO BE REMOVED FROM I LIFTS PRIOR TO A MAJOR WIND EVI PILINGS' PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB —SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH 2017 FBC. ALL PILINGS TO BE 1 0" MINIMUM DIAMETER. 2.5 C.C.A PRESSURE TREATED WOOD, PRE -STRESSED CONCRETE OR COMPARABLE EQUIVALENT. ELECTRICAL REVIEW. 1 HP ELECTRIC MOTOR 12.8 AMPS ® 115V EACH 6.4 AMPS ® 230V EACH QUANTITY- 2 TOTAL WATTS. • 2944 16,000 LB. CODA GEAR BOAT LIFT (2017 FBC) R. HYDE SCALE. NTS DA7E• 1/2/18 REV! 1 '017 d18 8 "fl/ NOTE TO EXAMINER: THIS CERTIFIED ENGINEERED DRAWING HAS BEEN PREPARED SPECIFICALLY FOR USE ONLY BY °000000po°°o°p0oo 0 a°°oo F, � e �9 oOOOo p % GE O r _ NO.4M p o 0 D JUN O 1 01 0 STATE OP 'w o 0 too °OOOo $ °pO 'onAoouo °oo0 ROGER BABER P.E. NO. 43855 CR PROFESSIONAL ENGINEERING C.A. NO. 26967 1014 NW PINELAKE DR. STUART, FL 34994 ING MOUNTING TABS FMU14 (2) 3/8" DIA. SS LAG TS FOR WOOD PILING OR CONCRETE ANCHORS FOR iCRETE PILINGS PER PILING )UIRED.MINIMUM (2) 3/8" SS CARRIAGE BOLT FOR n i i"ACHING MOUNTING TAB TO LIFT REQUIRED PER PILING. MOUNTING TAB CONSTRUCTED FROM 1/4" X 2" ALUMINUM 6 0 6 1- T 6 FLAT BAR. BOAMIF7S AND MARINE PRODUCTS 4050 SEL W 77 ROAD FORT PIERCE, FL 34981 1-800-544-0735 www.hi—tide.com