Loading...
HomeMy WebLinkAboutBUILDING PLAN PAGE 16-30TOP PLATE IlhL O.C. MAX. SECURE 2X4 W/ 2-1/4' TAPCONS OR DRIVE PIN (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Yd W/JJpp��@@ EA. END NOT TO EX�EE'� 2X4 SOLID ING SECUI� t AtFING WITH MIN. Zd PER BLK. EA. END *NOTE: NAIL 51 4r=AT4NG TO ALL 2X AS PER ;�XT. 6I41=ATI41NG NAILING, 8d 4" O.G. MAX tv rEDGES 4 (O"-8" O.C. MAX IN TNI= FIELD "mKmmPllr, R - - 11 BT. EXTERIOR ARCHWAY WITH WINDOW 1 SCALE: 1/2"=I'-0' /-F CLOSED VALLEY FLASHING DETAIL `J N.T.S. )32' O.G. 4 BOttc SECUW 70 WOOD W/1-12d a 6 O.C. 9TAGGERE SECURE 2X4 W/ 2-W6' TAPCONS OR DRIVE PIN (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4' W/IN 8' EA. END NOT TO EXCEED 18' O.G. MAI 2X4 SOLID BL SECURE TO 6HEA WITH MIN. 2-12d PER 2 EXTERIOR ARCHWAY SCALES 1/2'=1'-0' i - - ''��%� �—F2.5 EA. RAFTER 2x4 RAFTER 0 24' O.G. (TYP) �'� FRAMED OVERHANG N.T.B. 2X4 TOP PLAT] CLG. 2X4 SECURED TO GABLE ENG W/(2)1 O.C. UPRIGHT r P I/Z' C BOARD 1/2' CLG. BOARDy TRUSS - 4� 1/2' CLG. AID CONT. TAL WOOD 1/2' D ALL TRACKS, OP 4 00 UDS 616' BOTTOM C., U.OX 1/2' DRYWALL 1/2' DRYWAL 2X4 CONT. 2X4 WOOD 2X4 CONT. STRESS STUDS s*l STRESS BLOCKING O.G., U.ON. 0LOCKING 2X4 WOOD CHANNEL SHA MID -WALL MID -WALL SECURE ET. PLATE STUDS •24" STUDS 24' O.G. W t0 SLAB W/ 10d LAYER OF V2' SECURE Et. I/2'k9' A OL. TYPE GYPSUM PLATE TO S F I/2' DRYWALL 32' OC. MASONRY NAIL ® WALLBOA W/ 10d M� EMEE 32' OC. MAX ATT�AC NAIL • 32 O X4 PT. SIDE a 12 MAX SEipATI PLATE GONG. SLAB F DETAILS GONG. SLAB LONG. SLA 4 0" o d O.. ONC. SLAB ATION roR r ILs 5P 32' C. MAX 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR TYP.INT. WALL INT. BEARING WAL INT. BEARING W TYP.INT. WALL METAL STUDS (NO UPLIFT) (W/ UPLIFT) (NON—BRG.) NON—BRG. 8 SCALE: 1/2'-1'-0' SCALE: In'=I'-0' SCALE:I/2' -0° 8C SCALE: 1/2'-1'-0' SP4.32' M5TA-36 32' MAX SP4932' O C. AX tiJ TRU55 TO WOOD FRAMING SIMPSON "ITS-12 ® PRE-ENG. TRU55 DO TOP LATE 2 T O STRESS DEL. 2X TOP PLATE i I ID WALL T/IS' 0.5.5. a x e 8 16' O.G. MAX, OR 1/I6' ZIP SHEATHING N SYSTEM (INSTALLED PER MANUF. SPECS-) 4 SU15FLOOR GLUED 2X BLOCKING a REWED AS PER TOP OF A R SCHEDULE 1/2' CDX I FLOOR STUDS TO 2X STUDS IS' O.C. MAX. a FLOOR STUDS m 51MP50N M5TA-36 s 32' 2X BTM. PLATE O.G. MAX 3/4' FLOOR DECKING PRE- ENGINEERED FLOOR GIRDER PRE-ENG FLOOR TRUSS DOUBLE TOP PLATE PRE- ENGINEERED FLOOR TRUSS 2x CONtINOUS STRESS LOCKING MID WALL (D CONTINUOUS SHEATHING TO BEGIN AT TOP OF BLIC ----2 STUDS * 16' O.G. MAX, W/ 1/4' GAP FROM SLK t0 OLD. UA . --1/2WL. W. O HORIZONTAL 2X SPF. STRUCTURAL BLOCKING AT PERIMETEPROVIDE�l R OF OLD. t0 PROVIDE CONT. NAIL PAttE —SECU BT. PLATE r0 SLAB W 'x V ANCHOR 3U REMAINING AREA TO ME SHEATHED FROM DEL. TOP BOLT W/ WASHER SET IN PLATE TO HORIZONTAL FLOCKING. 81MP80N H STRENGTH EPDXY T' E ED. MIN. SHEATHING •TOP OF WOOD FRAMED WALL 70 EE STAGGERED MIN. OF IS' FROM SHEET BELOW 32Mp ON AX O INSTALL ALL SHEETS W/FACE GRAIN PARALLEL TO STUDS 2-STORY L,B. EXT. WALL SHEATHING SCALE: 1/2'-I'-0' 4 SCALE: I/2' = I' -0' SIZE PER DOOR/ WINDOW OPENING TYP. EXTERIOR WINDOW 4 ,� DOOR OPENING WD FRp SCALE: I/2'=1'-0' — 0�7■��L:I���Io 19 SECURE 2x4 ON� FLAT TO BLK W/ CUT NAILS. SIDES: 2X6 GARAGE DOOR BUCK W/ C5J 0 K'XS' A -BOLTS 4" EMBEDMENT MIN. O W/ 2"X2'X6 WASHER AND NUT SPACED EVENLY FROM FLOOR TO GARAGE DOOR HDR. IN JOINTS PRIOR TO FILLING, I-2X6 PT BLOCK a CENTER OF DOOR HEADER W/(I)A'XS" J-BOLTS 0 4" EMBEDMENT W/ VXVXYe' WASHER AND NUT. � INOTE9: ALL ANCHORS SHALL BE IN ACCORDANCE TO MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE SUCH INSTRUCTIONS ARE MORE STRINGENT GARAGE DOOR BUCK ATTACHMENT cJ SCALE: 1/2'•1'-0' " CDX PLYWOOD Of=ENING d 4 ° ° 4 ° PRECAST LINTEL 4 O a d ° d 4 ° ° 4 ° TO SECURE� ED MIN I/Z L tHAN 4 4 I I ', WIND T E a SE TO L K. 4 LOCKS 4 4 a IT BLOCK W/ (2) "x3" ON OR DRIVE PIN ( N ANK SIX 145) _ ( M5ED. I #") a IN 8' OF EACH D AND 1 C. MAX SPACI �- CMU W L 1 4 °4 ° 4 4 °4 d' d 4 °4 4 ° 4 4 ° d ° 4 Q 44 d ti ARCH WINDOW FRAME Cl SCALE- 3/4" = I' -,a" PRE-ENG TRUSSES W/ TUSS CONNECTOR VERIFY W17 FRAMING PLAN DOUBLE TOP PLATE GI LE STUDS* ° OC. A 5 PSON L_ -I2 ®EA. JACK �TUD, I30T IDES OF OPENING 2x St S +o I6' O.G. MAX W/ SH THING. SHEATHING TO BE KEHIN J' OF WINDOW/ DOOR NING AND SECURE f'ER NAILING SCHEDULE KING STUDS (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) JACK$ (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) JACK STUD ASSEMBLY TO FE SECURED ONE PLY a A TIME. SE 12d NAILS, TWO WITHIN 6° EACH E4 NO MORE TH 12' O.G. STAGGERED 9P4 H5 s TOP AND BOTT LATES +� EA. FULL LENGTH S D, BOTH SIDES OF OPENI SHEAruING r aP To BOTTOM OF NG'D TRUSS BELOW- SI­I3ATPIWx MUST NOT E14MAK 1'- " MIN. FROM 2ND FILM LINE. -ENG TRUSSES OR FRAMED RAFTERS 2x RIDGE ONE SIT RGER THAN RAFTS IZE MIN. (3) 12d NAILS MIN. (4) 10d GUN NAILS 2x4 COLLAR TIE AT EVERY OTHER RAFTER W/ MIN. (3) 12d NAILS OR MIN. (4) 10d GUN NAILS 2x RAFTERS Ix8 NAILER SECURE TO TRUSSES BELOW W/ (2) 12d NAILS OR (3) 10d GUN NAILS a EA. TRUSS RAFTER TO TRUSS MTS-12 CREATE VOID FOR STRAP PENETRATION ROOF DECKING OVER PRE-ENG TRUSSES �i����►C43I34t-� HEADER SIZE PER SPAN CHART. o� TYP. INTERIOR DOOR OPENING WD 5 REBAR VERT. IN SOLID GROUTED CELL 5/8' THICK 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONRY %A� CONV. FRAMED ROOF SCALE: PRE-ENG TRUSSES W/TRUSS CONNECTOR VERIFY W/ FRAMING PLAN DOUBLE TOP PLATE CRIPPLE STUDS • 16' O.C. MAX SIMPSON LSTA-12 +o A JACK "04 BOTH SI OF NG. 2 • 16' O.C. MAX W/ IN SHEATHING TO BE FFIN }' OF WINDOW/ DOOR OPENING AND SECURE PER NAILING SCHEDULE KING STUDS (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) JACKS (SEE FEADER SPAN CHART FOR DETAILS AND SPECIFICATION) QACK STUD ASSEMBLY TO BE RED ONE PLY s A TIME_ USE NAILS, TWO WITHIN 6' FROM E END 4 NO MOB THAN 12' O _ TAGGERED 1/2'x'5' A.B. MIN. i' EMEEDMENMT 8" F CH END 4 32' O.G. MAX SP4 OR H5 a TOP AND BOTTOM PLATES • EA FULL LENGTH STUD, BOTH SIDES OF OPENING. LINE OF SLAB COMER BEAD SEALANT 4 BACKER ROD 8' Cm SEE StRUCTURAL FOR REINFORCEMENT -2x6 P.t. WD ATTACHED TO FILL CELL AS PER PRODUCT SPPROVAL REG. FROM MIAMtI-DA05 COUNTY 11EATHER STRIP MOULDING ALL AROUND (BY DOOR MANUF ) GALV. STEEL . TRACK BRACKETS FASTENED TO WOOD JAMB W/ 3/16'x1 1/4' LAO GALv. STEEL vERtICAL TRACK OVERI.4EAD DOOR SCREWS BY MAUF. , I MIN. BY OTHERS FASTENED TO SLIDE TRACK BRACKETS ROOM W/ 1/4'-20XI/2' GARAGE DOOR JAMBS CARRIAGE BOLTS 13 �J SCALE: AND LOCK NUTS. PRE -ENCsk MTS-12 2X4 DSL. TOP PLATE OLD. SNEAT OR X4 STUDS 16' CDX PLYWOOD. T D PER FASTENER CHE illb" OSR- SET 2 A%, OR 1/16, zI SHE HI SYSTEMRTEXT. FINISH MANUF. S2x4PER\TR ST SCUREEETUJEEN S BAYS W/PRE-E 3) 12d' EACH END SSRED 2x DOUB TOP PLATE UPS IS, O.G. Mt -12 ® EVER STUD 2x4 BT. PLATE DORMER KNEE WALL DETAIL 16 SCALE:3/4'=1'-0' ATTACHMENT 15 SCALE:1/2"=I'-0' " IIi5 UPLIFT SIMPSOM PTOM20 111/10 10d TO TRUSS AND (4) 1/4' x 2 1/4' TAPCONS TO CANT POURED LINTEL M IcJ00 UPLIFT (2) SIMPSOM HTSM20 INSTALLED ON OPPOSITE FACES OF BLOCK WALL W/10 10d TO TRUSS AND (4) 1/4' x 2 1/4' TAPCONS TO CONT -POURED LINTEL PRE-ENG TRUSS CONTINUOUS BOND BEAM TRUSS ANCHOR 1 � RETROFIT N.tS. CONTROL DATE: 07/01/15 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 J Ir W `. a 0. A F A F� SLTHDIV. CREEKSIDE LOT 120 PROJECT# 04321.000L: MODE 4EAB "1672—ARIA" GARAGIC iVnNG: LEFT PAGE: misc. DETAILS t60 MPH EXP. C ARCHITECT STATE OF FLORIDA AY 2 5 18 ROLA?�D A ACRA AR NO 93723 PRIIZT DATE: 05/25/18 ®CALF: 1/4 SHEET D4 File Copy a(�, "'"i" r R�Io,,L,J�,,,• - Planning & Development Services Department • Building & Regulations Division Product Review Affidavit Building Permit # Owners Name Applicant Product Opening Design Product Rated Manufacturer Model # Product Approval Glass Type Method of Attachment Pressure Design Pressure Number 1/4" concrete screw 6" edge distance @head, 4" edge distance @jamb, 4" each side of transom centerline to Swing door ( +36 ) J ( 47 ) (+67 ) J ( 67 ) Therma-Tru Smooth Star FL20461.17 N/A bucking. Fastener spacing @ 15" o/c max. @head and jamb. Min. embedment of all anchors to be 1 1/4" Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 11 3/4" o/c at jamb, 16" @ head. 1 1/4" embedment. Type II: 3/16" or 1/4" ITW concrete to peon anchor. 6" max. from corners, 7 1/4" o/c at jamb, 10 1/4" SH Window (+38) / (-48) (+50) / (-50) Ply Gem Ply Gem 1500 FL16103.1-R9 Non Impact @ head. 1 1/4" embedment. Two additional tapcons midspan and one at lower frame required vertically each side. Install per manufacturers recommended requirements. Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 14" o/c at jamb, 10" @ head. 11/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. SH Window (Integral (+38) / (-48) (+50) J (-55) Ply Gem Ply Gem 1500 FL16100.1-R6 Non Impact from corners, 8 1/2" o/catjarnb, 6" @ head. 1 1/4" Mulled) embedment. Eight additional tapcons top and bottom required horitontally, one midspan vertically each side. Install per manufacturers recommended requirements. 1/4" concrete tapcon anchor. 2 1/2" minimum edge Builders Series distance. 6" max o/c from corners and 20 3/4" max o/c Sliding Glass Door +33 ( ) / {-41) (+50) / (-50) Ply Gem 4780 FL14634.2-R3 Non Impact elsewhere top, vertically and bottom. 2 1/2" min embedment. 1/4" concrete tapcon anchor. 6" max o/c for comers. Tapcon required 3" each side of center of opening top and Opaque single door (+36) / (-47) (+47) / (-47) Therma-Tru Smooth Star FL14985.1-R2 N/A bottom. Top and bottom centerline of each door slab get with transom tapcon. Rest of vertical o/c spacing is 14" max. 1 1/4" embedment. 3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C Double Garage Door (+29) / {-35} (+46) / (42) Clopay 16.20 73 W6 FL16546.6-R9 N/A Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" dia. heads, long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per Roof IKO Cambridge FL7006.1-1110 shingle placed 6-1/8"above the butt edge, approx. I" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. Miami -Dade approved corrosion resistant tin -caps and 12 Underlayment Interv✓rap RhinoRoof U20 FL15216.1-R3 gauge 1'/<<" annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll Soffit +31.6, -38.8 (+157) / (-46.1) PlyGem Variform Soffits FL24161.1 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels Hurricane Storm embedment @ 1 3/4" in concrete /masonry, 2 1/2" min. Less than 6' span (+47) / (-53) panel MFG. 24 GAGE FL16293-R2 edge distance 12" o/c max. spacing. Can be headed screw oral) thread but with wing nuts. 1J4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels 6' Hurricane Storm embedment @ 1 3/4" in concrete /masonry, 2 1/2" min. span or more (+45) / (-50) panel MFG. 24 GAGE FL16293-R2 edge distance 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts. Zip System Install per manufacturers recommended requirements. Huber Wall Sheathing 17147-112 Sheathing 1 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.a bdesigngroup.com AA #: 0003325 �11' chi w 0 F 0. U w A F q EF ti evsa=v ee zoT: CREEKSIDE LOT 120 P1iOJECTyJ: 04321.000 MODaI.r 4EAB "1672-ARIA" LEFT PAGE: PRODUCT APPROVALS 160 MPH EXP. CMY ARCHITECT - STATE OF FLORIDA i' i j ROLAVQ A HACRA AR NO 93723 rasaam a aATZ: 05/25/18 ®CAI. 1/4"=1'-0" NO cony NOTE: NOTE: NOTE. IF ZIP SHEATHING SYSTEM 15 APPROVED BUILDING WRAP IF ZIP 51-4EATHING SYSTEM 15 \ INSTALLED, PLEASE SEE SHALL BE LAPPED A MINIMUM OF INSTALLED, PLEASE SEE 4'x4" SELF -ADHERING MEMBRANE MANUFACTURERS 6" a VERTICAL LAPS (ROLL MANUFACTURERS FLASHING (COMPATIBLE I.U/ HOUSE 4 ENDS) 4 6' a HORIZONTAL LAPS. WRAP MATERIAL) OVER INSTALLATION PROCEDURES ALL SEAMS NEED TO BE TAPED LATH VERTICAL LAP TO BE I' INSTALLATION PROCEDURES APPROVED HOUSE I WITH FORTIBER SHEATHING TAPE .� FLASHING TO EXTEND ONTO PIPE �. / I" OR LESS PIPE ` 6'x6' SELF -ADHERING MEMBRANE PREFORMED CONTROL JOINT — THICK, 3 COAT CEMENT PENETRATION FLASHING (COMPATIBLE W/ HOUSE WRAP MATERIAL) OVER 4'x4' FLANGE OF CONTROL JOINTS T PLASTER / \ \H � / SELF-ADHERING OVER APPROVED BE WIRED TIED TO LATH 13 WRB LAYER 02, FORTIFIBER / WRAP. O.C. MAX (VERT.). NOTE: DO BUILDING PAPER I" MIN. LAP ® METAL LATH NOT FASTEN CONTROL JOINT TO / \ HOUSE�` FLASHING TO EXTEND ONTO PIPE WALL EVEN IF STUD EXISTS BEYOND EXCEPT STAPLES W/ APPROVED METAL LATH %' LEG MAY BE USED TO TEMP. FASTENED 01' (VERT.) O.G. MAX X X X l SECURE CONTROL JOINT AT SUPPORTS X X X DURING INSTALLATION CUT AND OVERLAP ONE SIDE OF \ FASTENERS TO BE SPACED SST CCOYWRAP GUT AND OVERLAP �lE SIDE OF METAL LATH SELF -ADHERING MEMBRANE • -T' O.G. MAX VERTICALLY SELF -ADHERING MEMBRANE WOOD SHEATHING I `S� `S� FLASHING OR i/16' ZIP SHEATHING i / / WRB LAYER "I, �' THICK, 3 COAT CEMENT SYSTEM A NSTALLED PER �j STUCCO WRAP PLASTER WRB LAYER "I, STUCCO WRAP MAPAUF 5H'ECS.) METAL LATH n 1 b" MIN PAPER LAP BELOW ONLY WRB LAYER ^'2, FORTIFIBER WRB LAYER 112, FORTIFIBER BUILDING PAPER WR5 LAYER #2, FORTIFIBER BUILDING PAPER BUILDING PAPER / METAL LATH 77/ / \ ` / / I STUCCO LAYER "I, 6"xb' SELF -ADHERING MEMBRANE ASTUCCO WRAP FLASHING OVER 4'x4' SELF -ADHERING MEMBRANE J° TO §' I INSTALL FASTENERS (CLIPS, FLASHING OVER APPROVED LATH SHALL NOT SAP MIN. WOOD SHEATHING STRAPS, STAPLES) AS HOLLSE WRAP. �' TO a^ 6' Toe REQUIRED TO SECURE BE CONTINUOUS OR 7/16' TIP SHEATHING THROUGH CONTROL MIN, MIN" SYSTEM (INSTALLED PER FLASHING TO EXTEND ONTO PIPE JOINTS BUT SHALL M F. SPECS) PIPE/ WIRE TO FRAMING 4'x4' SELF -ADHERING MEMBRANE BE STOPPED S AND " rpq, w, a R „ s a FLASHING OVER APPROVED HOUSE WRAP. TIED AT EACH SIDE. PROVIDE 2X4 BLOCKING MIN LATH ACHING TO EXTEND ONTO PIPE PER ASTM CI063 PLACED FLAT MAX 6' TO 8' LAA LAP R i.lID.l.4 FROM CONTROL JOINT WHEN CONTROL JOINT FALLS ON APER LAP NOTE: \ / STRUCTURAL STUD � SCALE: 11/2'=I'-®' ii' GONT. BEAD OF SEALANT 1, FASTENERS FOR LATH TO BE NAILS OR INSTALL APPROVED HOUSEWRAP AIR STAPLES IN COMPLIANCE W/ ASTM C1063 INFILTRATION BARRIER OVER 2. WIRE TIES TO BE (NO. 10) 0f0475' WIRE / _ 3. BLOCKING SHOWN MAY BE IN ADDITIOy \ IELA TOM R(C �YP WALL SECTION) / TO WALL STUDS REQUIRED PER PLANC.V/ VERTICAL LATH & PAPER DETAIL WOOD STUDB a 14 SECTION ION PER SECTION R703.7 i 4+ Exterior lathing and plastering NOTE- SHEATHING Exterior use of portland cement plaster SIDE LAPS OF METAL OR 7A6' ZIP SHEATHING SYSTEM ,I shall comply with the application PLASTER BASES SHALL (INSTALLED PER MANUF. SPECS) t w requirements of ASTM C 926r12A. BE SECURED TO BUILDING NOTE: J 6" MIN. IF ZIP SHEATHING SYSTEM 15 Installation of exterior lathingand framing shall comply with ASTM C 1063-12A. „ FRAMING MEMBERS. PAPER LAP INSTALLED, PLEASE SEE M TYPE CONTROL JOINT THEY SHALL BE TIED 1 BETWEEN SUPPORTS' MANUFACTURERS WITH m�4T5-IN. (I.21-MM) STUCCO M° LAP a LATH WIRE AT INTERVALS NOT 3" LAP ° PAPER INSTALLATION PROCEDURES MORE THAN 9' (22S-MM). E AS O PER ASTM Cl063 I. FOLD I1 Pr. A i f) L FOLD INWARD 0 M A .I. �� F I F F N T IRA T I O Tel IDTAIL C IR� i� l a ct�Aee . Pr. B NOTE. ®FOLD ® 4 K�CKC7U'�' pOR�PAIROFTEARS HORIZONTAL LATH N,..�. DETAIL M Y B LAYERS, TEARS Mar BE PATCHED & PAPER DETAIL W/HOUSE WRAP TAPE PER MAIM SPEC. OR FOLD PEEL 4 STICK 1 46• +� , ® 1/lro" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS) OR O1. FOLD INWARD 1 ( L FOLD INWARD 1 Pr. A WOOD SHEATHING OR CMU Pr. A J z. 0Aee • Pr. s WR5 LATER #I, 7. CII a FT.5 %CREASE 1 Pr. C i ''.::: STUCCO WRAP (FRAME ONLY) 3. CREASE • PT. C 4. FOLD Pr. C OVER Pr. B TILL Pr. G TOUCHES BOTTOM PLAW-E ® I"" THICK, 3 COAT CEMENT ® PLASTER (FRAME), 1/2" 2 COAT CEMENT PLASTER (GMU) LEGEND lift`METAL LATH (FRAME ONLY) F LAP WRB 4 TAPE OVER ® ® RooF/WALL scREED DfiR>�INE'L,N (LUi� . LO R. P ANC , Rr LA'T' IR #1, STUCCO UJIRAP) NOTE: SEAL FOLD, 22CUT , IF ZIP SHEATHING SYSTEM IS �" INSTALLED, PLEASE SEE d' THICK 3 COAT CEMENT z 5"X$" "L" TYPE CONTINUOUS LUIR5 L XrE R *12 C FOF�.T IF BE R — — — — — — PLASTER !PRAM(), la' 7 COAT CxAL V. METAL FLASHING I I P� ) MANUFACTURERS cNrPLAerER(cMu) (NAIL TO ROOF DECK, NOT INSTALLATION PROCEDURES UIRB LAYER 02, FORTIFOER a) E BUILDING PAPER(FRAME ONLY) WALL SHEATHING) WR8 LAYER w, � GAP SHINGLE - DO NOT NAIL, 1"IETAL LATI4 x x x x STUCCO WRAP (FRAME ONLY) INSTALL WITH ROOF CEMENT LAP LAYERS OF BUILDING+ WRAP OVER NAILMG FLANGE, STOP ASOVE BµINGL 4 ��.� STUCCO � 4-- - a E�EIR Ct'U ROCFAUALL GGRIM2 �� �`� ROOF CEMENT r� III _ NING �, ROOF PER ELEVATIONS WOOD SITIINC Su5WALLFLAS `U o f OR rtIlroll ZIP 5HEATHING SYSTEM KIM-IL) OUT 1tea/ IINStALLED PER MANU1=. SPECS) NOTE: IF ZIP SHEATHING SYSTEM IS NOTE: INSTALLED, PLEASE SEE MANUFACTURERS 1*-1ETAL LATE: LAT�4 TO 8E i=EIR SECTION FELT UNDERLAYMENT INSTALLATION PROCEDURES \ \ / {t WATER rSEAL (�FTID OR /y RDr>°NOT �O NOTE,_ f INSTALL T 811 ROO4 FAT 8orrom RDOF . WAILLI jRjERBOTION6 DRIPEDGE, DVt"RL EMEND II BELOW 19LY FASCIA WRAP &-IEATHMCs, MECHANICALLLATI4 DOES NOT 1 I'EET SPEC IPICAT IONS) FASTEN 4' O.G. MAX "L" F L A K I N G 5 N.T.S. 1 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 W y W U W 0 0. a U W 4 F SVHDM as LOT: CREEKSIDE LOT 120 PROJECT# 04321.000 MODEL: 4EAB "1672—ARIA" GARAGE OWING: LEFT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARC HrrECT STATE OF FLORIDA 5 05/25/18 SCALE: 1/4"=1'-0" SHEET WA1 File Copy NOTE: IF ZIP SH THING SYSTEM IS INSTALLED, LEASE SEE I~1ANUFACTU RS INSTALLATION ROCEDUIRES BACKER ROD BACKER ROD WRB LAYER 01, STUCCO WRAP f1 ]DRYER VENT e° cMU INSTALL 6" SELF-ADH MEMBRANE FLASHING TOP, SIDE(S) AND BO FLANGES OF NON -MO FRAME OF THE EXHjL VENT,944e IS BE SET IN BED r T T TOP AND SEALANT IS TO BE AS TO DEFLECT AY FROM JOINTS. ALL AROUND PLY SEALANT ALL ND INTERSECTIONS EALANT AT PERIMETER OF ABLE FRAME AND STUCCO IDES, Y4" CAULKING 9 JOINT ALL AROUND PER SECTION R703.7 Exterior lathing and plastering Exterior use of portiand cement plaster shall comply with the application requirements of ASTM C 926-12A. In Ilation of exterior lathing and framing shall molV with ASTM C 1063-12A. HOODED VE T g' THICK, 3 COA PLASTER METAL LATH WRB LAYER 02, FOF BUILDING PAPER WOOD SHEATHING WRAME /�INOTAAN PER MANUF. 8 CS-) OR EATHING ER0, WRAP ER , FORTIFIBER P R ATH51NG BEADD BAND Ye' TO V MIID-WALL WEEP SCE =D roll WIDE STRIP SELF ADHESIVE FLASHING, CLEAN MASONRY 6EFORE APPLYING Z FLASHING OVER JGRATCH COAT H IZONTAL WEEP SC ED W/STONE VENEER (FRAME TO BLOCK DRAINAGE PLANE (UJRB LAYER #1, STUCCO UJRAP) LJRB LAYER #2 (FORTF BER - - - - - BUILDING 1=APER) illIETAL LATH x- X—x—x STUCCO C " LJOOD 5I4E,ATI41NG OR 1/16" ZIP SHEATHING SYSTEM ( INSTALLED PER MANUF. SPECS.) SELF-ADHESIVE FL,4514ING - — - NOTE: 1* IETAL LAT�4: LATH TO BE PER SECTION Rrt03.1.1 / ASTM C-S4rt -09, MIN. 2.5 L85. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET 5PECIFIC�ATION5) ELEC. METEi VERIFY LO STUCCO FINISH (a" SELF ADHESIVE OVER TOP 4 SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT s TOP 4 SIDES 6B DRYER VENT (BLOCK BUILDING PAPER OVER "QUICK FLASH" PIPE THROUGH WALL I C6" SELF ADHESIVE — FLASHING (INSTALL PER MANUF. SPECS.) BUILDING PAPER — UNDER 'QUICK FLASH" HO IZONT (FRAM WOODCONSTRUCTI 7/16' ZIP SHEATHING SY EM T/16" ZIP SHEATHING SYSTEM (INSTALLED PER MAN . SPEGSJ OR (INSTALLED PER MANUF. SPECS.) OR WOOD SHEATHI Cx WOOD SHEATHING WRB L�R # , ` WRB LAYER MI, STUCCO WRAP STUGG�UJyC P yy WRB LAYER 02, FORTIFIBER BUILDING PAPER � ER "2, FORTIFIBER '' METAL LATH {�Ull,! G PAPER WOOD CONSTRUCTION�FINISII ' NNI TEXTURED ®WOOD �1 ,I FASTEN TO WOOD STRUCTURAL MEMBER • r° O.C. MAX ° THICK, 3 COAT CEMENT s° cMU LASTER �' TO J4' AID -WALL f WEEP SCREEP 'T " TO Tall MID -WALL. _ AIL W P SCREEID ro' WIDE STRIP SELF ADHESIVE FLASHING, CLEAN MASONRY BEFORE APPLYING roll SEL DHESIVETExruRED FLASHINCz FINISH MASONRY WOOD FRA D WALL rrB HORIZONTAL O WEEP SCREED (FRAME TO BLOCK) EEP SCR D NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES / NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES A VENT PENETRATION SCALE: N.T.S. STUCCO SCRATCH COAT 4 1 COAT OF PAINT W/BACK- ROLL PRIOR TO ELEC. METER INSTALLATION -ELEC. METER FIELD VERIFY LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEND FOAM nv rr At nti irru .)R SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC. WIRE PENETRATES :O SCRATCH GOAT LARGER THAN THE ELEC. METER CAN OR METER CAN COMBO OR METER CAN AND DISCONNECT O ELECTRICAL CONDUIT PENETRATION CUT OPENING IN APPROVED HOUSEWRAP FOR BOX INSTALLATION WRB LAYER "I, STUCCO WRAP WOOD &HEATHY APPROVED HOUSEWRAP BELOW CUT SUCH THA' NO MEMBRANE ENTERS BOX, APPLY TO FA( EDGE APPLY E-Z BEAI OVER 60 MIN GRAPE °D° FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS 5TE '*I - 5TE3 .0.0.0.0 .0.0.0 0 .0 0• 0• ♦O .0 0. O. .0 •0 0. 0. eo 0. .o e o. ;,1. o .o.o.o a NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WRB LAYER 01, STUCCO WRAP CUT "X" INTO SELF -ADHERING X MEMBRANE FLASHING f APPLY SELF -ADHERING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRB LAYER •I 5TF #2 WRB LAYER 01, STUCCO WRAP APPLY 60 MIN SELF-AD�4ERING .10 MEMBRANEFLASHING GRADE: "D' FELT OVER SELF -ADHERING FLASHING OVER APROVED HOUSEWRAP WRB LAYER 02, FORTIFIBER BUILDING PAPER STE F '*4 ELASTOMERIC COATING OVER STUCCO/ C.V. FINISH (SEE TYPICAL WALL SECTION) METAL LATH SfiEP *� STEP #6 OELECTRICAL RECEPTACLE 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 J w U W F Ell 4 F a sysarv. a� LOT: CREEKSIDE LOT 120 PR,OJ'ECT# 04321.000 MODIETa 4EAB 1672- ARIA" GA6BAGE ewMG.: LEFT PAG IC: WALL ASSEMBLY DETAILS 160 MPH EV. C ARCHITECT: STATE OF FLORIDA fD;AM 05/25/18M 1/4"=1'-0" Si3��T 1 U1 File Copy WOOD SHEATHING WOOD CONSTRUCTION Y4" HAT CHANNE W/a/e" TYPE "X' WOOD SHEATHING WRB LAYER "I, STUCCO WRAP ' THICK, 3 COAT CEMENT PLASTER WRB LAYER *I, STUCCO WRAP AMIGO AM66-WFWC-780 CUSTOM CASING BEAD (SHOWN PO CLARIFICATION OF SEPARAT ACCESSORIES ONLY) ASING BEAD 10 A DTL. CD CANT SCALE: WRB LAYER "I, STUCCO WRAP WRB LAYER '"2, FORTIF R BUILDING PAPER " THICK, 3 COAT MENT PLASTER 6' SAP. a TOP WEEP SCREED t0 Ys HIND WEEP SCREED PAN cY1 Y2u 6' SELF -ADHERING FLASHING WRAPPED 0 TOP OF WEEP SCREED TO SHEATHING BELOW _ WRB LAYER "I, STUCCO WRAP — WRB LAYER 1*2, FORTIFIE BUILDING PAPER 6' SELF -ADHERING FLASHING WRAPPED o CORNER OP CANTILEVER IF ZIP sHEATHINd INSTALLED, PLE,4 MANUFACTURERS INSTALLATION PF EXT. FRAMED WALL PRE-ENCs'D S: WEATHER REVSTI BARRIER WEATHER RESISTIVE BARRIER "2 >' THICK, 3 coat CEMEN• PLASTER METAL LATH WOOD SHEATHING 4" POSITIVE DRAIN WEEP SCREED t (SHOWN FOP SEPARATE A, IES , I "'k,� a� VIES FIN OFNLY) EXTERIOR GRADE DRY WALL J" THICK, 3 COAT CEMIE PLASTER VINYL CORNER BEAD 10 CANTI]LEVER DR STEM 15 EDGE SEE II �j URES L E G N -1)"' I"IETAL LATE: LATE TO 5E FER SrEGTf R103.1,1 / AST1"I G - B4-I - 09, 1„I IN. 2.r:;) S. 1=ER SQ_ *rARD (UTIL ITT OR NOM AL L + DOES NOT 1 IE T S 17-EC;1F TIONS) NOTE` OD CONSTRUCTION IF ZIP SING SY E IS EASE INSTALLED, P MANUFACTU RS WEATHER RESISTIVE INSTALLATIONC PROED RES BARRIER "I 3/4 RESILI t WEATHER RESISTIVE HAT CHANNEL BARRIER 02 VINYL CAS EA ;.; THICK, 3 COAT CEMENT Iff PLASTER 5/8' TYKE WALL METAL LATH i" -I GOAT CEMENT VINYL CASING BEAD 11D DRIP EDGE INSTALLATION NOTE: IF ZIP SHEATHING SS IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES 5/8" TYPE 'X" DRYWALL WITEXTURED k PAINTED FINISH i" THICK, 3 COAT CEMENT PLASTER (SHOWN FOR CLARIFICATION,,.OP SEPARATE ACCESSORIES Y) WOOD CONSTRUCITON WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER "2 J" THICK, 3 COAT CEMENT PLASTER METAL LATH W?R- 210 a4A cs X VINYL CORNER BEAD VINYL CORP. 4' POSITIVE DRAIN - WEEP SCREED VINYL CASING BEAD NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) 11EDRIP EDGE INSTALL T� ION DRAINAGE PLANE (Wf;R LATER #1, STUGGO UJRAP) LJRB LANIIII #2 (r-ORT11=1BER PUILDING PAPER) i" IETAL LATH STUGGO UJOCD SHEATHING OR rt/Iro" ZIP SHEATHING SYSTEM ( INSTALLED PER MANUF. SPECS.) SELF-ADHESIVE FLASHING x x x x FINISH LAYER (2 LAYER 3' X 3' 26 GA. GA EEL k STICK) METAL DRIP ED SET IN FULL B OP 6' EL k SEALANT, �4' STI a DRIP SPACE FRO DRIP EDG O FACE t0 t X DECK ' Ya FOR BACKER 11 I ii"XI %,, Pt. SIMULATED RO k SEALANT WOOD (TREX) LER, /—INYLCASING .A CONTINUOUS WATER PROOFING I WEATHER RESISTIVE LAYER (2 LAYER P L k\, BARRIER 01 STICK) WRAPPED FIR- WEATHER RESISTIVE BALCONY DECK TO / BARRIER 02 CANTILEVER APAW 6 PEEL k STICK a 1, DRIP EDGE TO DECK DECK MEMBRANE, SUB FLOOR ; EXTEND OVER DRIP ®® EDGE 3" X 3' 26 GA. GALV. METAL DRIP EDGE --------------------------------------------- Itm ---- = - - SET IN FULL BED OF I"XI 3/4" P.T. OR I A SEALANT, J2" MIN, WOOD ITREX) FI E SPACE FROM DRIP CONTINUOUS FACE TO TREX 1V4" GAF, FO f � INY CASIN B AD ROD k SEAL W TER PROOFING Ist FINISH LAYER 2 AYER TI LA R l2 LAYER PEEL k PEEL 4 STICK) STIG WRAPPED FROM 3/4 RESILIEN BALC Y DECK TO HAT CHANN CANtIL R VINYL CASIN A THICK, COAT CEMENT PLASTER METAL LATH 5/W TYPE DRYWALL WOOD SHEAT W/TEXTURE k PAINTED WEATHER RESIS VE FINISH BARRIER M WEATHER RESISTI THIC 3 COAT CEMENT BARRIER 02 PLAS R 4, POSITIVE DRAIN VINY CORNER BEAD WEEP SCREED VoYL CASING 5EAD NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) BALCONY DRIP 11A EDGE INSTALLATION � CORNER 2 1 /2 11 2x 1=RAMING MEMBER $° TRICK, 3 COAT CE>1 T PLASTER 1=A SI--4EATI-41NCz AX. B LAYER 01, STUCCO WRAP OOD SHEATHING MET LATH WRB LATE FORTIP15ER BUILDING PAP BEAD (�P FR E CORNER BEAD 0=A5TENER 4 SPACING a I" O.C.) CMU V THICK, 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 1 Ap)CORNER BEAD k 51JOCK JL 11 JLl / COLUMN SHEATHING WEATHER RESISTIVE BARRIER "1 WEATHER RESISTIVE BARRIER "2 PEEL k STICK r I Vx3° °L' FLASHING f FULLY EMBEDDED IN ROOF CEMENT 1 ,�' X 3" 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OP Y4" GAP FOR BACKER SEALANt,1�" M ROD k SEALANT SPACE FRO RI FACE TO VINYL CASING BEAD WATER PROOFING 1st LAYER (2 LAYER PEEL ALL"IN k STICK) APAWFM PUTy o PEEL k ICK SUB PLO R yR SIMI FILLER EALANT ROD.T HAT CHANNEL WEATHER RESISTIVE BARRIER "1 WEATHER RESISTIVE BARRIER "2 EXTERIOR COLUMN -COLUMN SHEATHING: \6" SAP. -11{:"x3' 'L' FLASHING "FULLY EMBEDDED IN ROOF CEMENT I X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, ,lf MIN. SPACE FROM DRIP 'FACE TO TREX VINYL CASING BEAD WATER PROOFING lot LAYER (2 LAYER PEEL k STICK) WRAPPED FROM BALCONY DECK TO ANTILEVER i" ICK, 3 COAT CEMENT PL TER 5/8' TYPE 'X' DRYWALL \ METAL ATH W/iEXTUREP k PAINTED WOOD S AtHING FINISH 8" THICK, 3 COAT CEMENT 4 POSIT( IN PLASTER II SG NO GAP IN FIELD VINYL COMER BEAD (SHOWN FOR CLARIFIR ION OP VINYL CASING BEAD SEPARATE ACCESSS ONLY BALCONY DRIP 11C EDGE INSTALLATION @ COLUMN ( W/" L" FLASHING) SCALE: NTS WOOD SHEATHING NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE WRB LAYER "I, MANUFACTURERS STUCCO WRAP ' > INSTALLATION PROCEDURES WOOD 5I-4EATI-•41NCz WRB LAYER 02, ORTIFIBER : ,' BUILDING PAPE . T x ; WRB LAYER 01, METAL LATH > STUCCO WRA THICK, 3 COAT CEME WRB LAY *2, FORTIFIBER PLASTER 5 ILDIN PAPER "SELF-ADHERINCx r„ - I META ATH4 FLASHING / `'� (EXPLoD $B T ICK, 3 COAT CEMENT �VsW FO _ ASTER DRIP CAP ) �` ;q WINpOUJ FLANGE WRB'LAIYER "I, STUCG WRAP WRB LAY a'2, TIF15ER • � 5UILDIN METAL LA 1 = " THIC COAT CEMENT PLAST ro"S LF-ADHERING F SHING !III 'I — DRIP WINDOW FLANGE 155 CA ING BEAD @ WINDOW ( FRAME, NO BAND) 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 J F W W v W 4 0 a F A ti SUBDrv. de LOT: CREEKSIDE LOT 120 PROJECT# 04321.000 NNN MODEL: 4EAB 1672— ARIA" GARAGE 81PMG: LEFT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP, C ,40 ARCHITECT: STATE OF FLORIDA MAY DATE., 05/25/18 SCALE: 1 /4" = V — 0" SHEET File Copy WOODL SHEATHING WRB LAYN #I, STUCCO WR WRB LAYER #2, IFIBI= BUILDING PAPER METAL LATH " THICK, 3 COAT CEMENT PLASTER 6 "SELF -ADHERING — FLASHING VINYL ANGLED / CASING BEAD DRIP CAP WINDOW FLANGE NOTE: IF ZIP 5HEATHING 5Y5TEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD SHEATH WRB LATER STUCCO W P WRB L ER 02, 1=0RT11=1BER BUIL G PAPER AL LATH ✓" THICK, 3 COAT CEMENT PLASTER LAY #1, -~ S C v AY ANG >` ING EAD Y RB LAYER #2, FORTIF EIR BUILDING PAPER METAL LATH " THICK, 3 COAT CEMENT PLASTER 6°SELF-ADI-�ERINC•s ,,:; .! FLASHING DRIP CAP WINDOW FLANGE CASING BEAD C WINDOW 5C (]FRAME, W/BAND) SHEATHING METAL LAT WRB LAYER #i, STUCCO WRAP WRB LAYER #2, F-ORTIP15E BUILDING PAPER $" THICK, 3 COAT CEMENT PLASTER VINYL ANGLED CASING BEAD VINYL CASING BEAD NOTE: IF ZIP 5HEATHINGi SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD SI4EAT Y4" rzAP TYF e451NG BEAD TO TRIM IX TRIM MBER tv STUCCO SIDING TRAN ION ID ING r loe (/ WRB LAYER #I, STUCCO WRAP O " THICK, 3 COAT C NT PLASTER METAL LATH L ER #2, FORTIFIBER I ING PAPI=R 'WOOD SHEATHING WRB LAYER #I, STUCCO WRAP 6" -5ELrss4DHEREING FLASHING PEEL E STICK SIDING TO S TUC O CASING BEAD (CROSS SECTION) WOOD CONSTRUCTION BEYOND WOOD SHEATHING — WEATHER RESISTIVE BARRIER M WBQTHER RESISTIVE - BA IER "2 {,6X�1' LAP SIDING l6' SELF -AD ING - FLASHING STARTER STRIP DO NOT CAULK OR — SEAL OPENING GALV'D METAL "z' FLASHING I Y1 X 6' SIMULATED - WOOD TRIM MEM5ER SIDING TO STUCCO C BLOCK TO FRAME TRANSITION Nok%s' NO p6MULATED TRM MEMsr=R L GAP W/CAULKING APPROVED SEALANT ------------ SEALANT WINDOW 2X FRAMING '+ MEMBER SEALANT INDOW FRAME INDOW FLANGE NOTE: f IETAL LATH: LATH TO BE PER SECTION 2X FRAMING ASTM C-54-7-09, MIN. 2.5 L55. MEMBER PER 5Q. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) BUILDING WRAP -_-- CONSTRUCTIONS `- - ------------------- WOOD SH THING WEATHER STIVE-,- BARRIER m WEATHER RESISTf IIIIII } p bEA, RRIEYR� 02 WfR5 L `AI�Ef 'L1 Fi0I\TIFI5 IR U//6Fir= ALAPSfDING 5U I L D I1 G i=A PE Fes' " S P--ADG HERIN--� �IE I AL L A l i4 STARTER STRIP DO NOT GAU�K OR I REAL OPENING ��� �TER GALV'D METAL z' PLASHING I Y' x 6' SIMULATED U1�10p TRIM MENER CASING BEAD @) RAISED BAND (FRAME) SCALE: 1 1/2"=1'-O" / HER RESISTIVE BRIER Of TO LAP OP 7' FALASHIINGTOP 0- / 1 0 WEATHER RESISTIVE BARRIER "1 Z WEATHER RESISTIVE / BARRIER 02 / GALV'D METAL 'T' FLASHING / DO NOT CAULK OR OilSEAL OPENING /' WEATHER RESISTIVE BARRIER 01 TO LAP 6' MIN. ABOVE TOP 1 7' FLASHING ` I Ya' X 6' SIMULATED (IMMW FLEXIBLE PVC / WOOD TRIM MEMBER BACKER ROD) \ 'SELF -ADHERING 6' SELP-ADHERING I I i j ING FLASHING Ns' THICK, 3 COAT \1 ' SEAL AP W/CAULKING CEMENT PLASTER OR AP VED SEALANT WEATHER RESISTIVE WEATHER SISTIVE BARRIER "1 BARRIER M WEATHER RESIrg-Z BEADVI BARRIER 02 (1111V FLEXIBLE BACKER ROD) SIDING TO STUCCO 5 ATPERRE8ISTIVE 0 FRAME TO FRAME BARRIER 02 TRANSITION L7C' U IN 15 " THICK, 3 COAT CEMENT PLASTER METAL LATH m d o WRB LAY #2, FORtIFIBER •-------.................................................. BUILDIN PAPER E-Z BEAD VINYL CASING (W/3/a" FLEXIBLE PVC 54ll ROD) WRB LAYER01, yUCCO WRAP, WRAPPED 7�4rmsl�Vr= ND FRAMING MEMBER 6" L A FLASHING EATH ING T ELO W EXPLODED O R CLARITY ; .' ------------------------------------------------ g" THICK, 3 COAT CEMENT BEAD PLASTER DOUJ METAL LATH +++ WRB LAYER 02, PORTIPIBER UILDING PAPER Lu\wD SHEATHING WRB LAYER 01, STUCCO WRAP 6" WIDE PEEL E STIC OVER FLANGE E-Z BEAD VINYL CASING CWA/8" FLEXIBLE PVC BACk *APPLY FULL BED OF SEALANT BE FLANGE' E BUILDING WRAP LEGEND DRAINAGE PLANE (WRB LAYER 01, STUCCO WRAP) WRB LAYER #2 (PORTIPIBER — — — — BUILDING PAPER) METAL LATH X—X—X—x STUCCO WOOD SHEATHING OR 7116' ZIP SHF-ATHING SYSTEM (INSTALLED PER MANUP. SPECS.) 5ELI=—ADHE5IVE PLASHING — — — ROD) II .1 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 w y U w 0 F a U w A F A ti avaarv. ae LOT: CREEKSIDE LOT 120 PROJECT# 04321.000 MODELt 4EAB 1672- ARIA" GARACaxE SIVING: LEFT PACE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA L A. AWUCHACRA NO 93723 DAFT, 05/25/18 mcALm 1/4"=1'-0" V G A4 j File Copy OUT HOUSEM AT 40' ANGLE MODIFIED "I' GUT IN HOUSEWRAP LINE OF WINDOW - OPENING APPROVED HOUSEWRAP OVER SHEATHING OVER U,D STUD UALL STEP 1 INSTALL b' SELF -ADHERING FLASHING OVER NAILING FLANGE AT JAMBS EMEND FLASHING MIN 1' BELOW SILL FLEXIBLE FLASHING DO NOT SEAL BOTTOM FIN STEP 6 NOTE: IF Z f 5�4ATE f N 5�ST r%ol le f NSTAL L , f::)OcL�5 APPLY MEMBRANE FLASHING OVER JOINT 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngrou p.00m AA #: 000332504 F W W U W h a r7 a F A C: stmi)m ee LOT: CREEKSIDE LOT 120 PROJECT# 04321.000 MODErr 4EAB "1672— ARIA" GARAGE s'1 MG: LEFT PAGE: WALL ASSEMBLY DETAILS: WINDOW FLASHING 160 MPH EXP. C ARCHITECT STATE OF FLORIDA n _/ / DRINT AATW. 05/25/18 8CAL's: 1/4"=1'-0" sIKERT File Cody I I I I 1 1 2x(o SUB-BANp W/I "x4" NOTC 4 s END, WRAPPED IN PEEL 4 STICK DRIP EDGE t/5" TEXTURED FINISH 6 WOOD 1/2" TEXTURED FINIS! 4 a CMU METAL FA I� I\ 1` I` 1 ` I � 2X6 SUB E I ` METAL FASCIA \ WRAP Ya" FROM ` STUCCO, I" FROI" I \\ WOOD WALL \ EXTERIOR WALL 1 (FRArlE OR CMU) \ NOTE: NOTCI-4 FOR 2X(o SUB BAND ONLY �\ I �—r \ —ROOF KICK OUT REMOVED �\ FOR CLARITY —ROOF DECK (BEYOND) DRIP EDGE, 1" OFF WALL =rz1- `SNOT INTO STUCCO) 1-1/8" TEXTURED FIN1S4 4 / WOOD, 1/2" TEXTURED FIN15H tv C1"iU 2xro SUB -BAND W/I"x4" NOTCH a \ END, WRAPPED IN PEEL 4 STICK METAL FASCIA WRAP 1" OFF WOOD WALL. SUB BAND 2" OFF WOOD WALL 7/8' TEXTURED FINISH a LUOOD, 1/2" tr=XTUR1=D FINISH m CMU METAL LATH LUOOD 5H:=ATHINr% OR CMU LUR5 LAYER 01, STUCCO LURAP IFRAME ONLY) WRB LAYER 02, FORTIFIBERR BUILDING PAPER (FRAME ONL r) ROOFING CEMENT DRIP EC)GE METAL KICK OUT NOTE - IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES PRE-ENG'D TRUSS TO BE CUT 6 WALL LINE TO AVOID CONTACT W/TEXTURED FIN15N 2 "x4"x4' -m" SCABBED TO TRUSS W/126 NAILS (o"-8" O.G. MAX. 2x SUB -BAND W/I2"x4" NOTCH 6 END METAL FASCIA WRAP DRIP EDGE EXTERIOR WALL (FRAME OR CMU) SUB BAND DETAIL ® WALL SUB BAND DETAIL Cap WALL W/KIC K— O UT FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN./4` ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/I2"x4" NOTCH 6 END, WRAPPED IN PEEL 4 STICK *ROOF CEMENT ROOF EDGE OMITTED FOR CLARITY FRAME OR CMU WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COI" IPONENT8) METAL FLA54NG, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x 5U5-5AND W/UZ"x4" NOTC44 a END, WRAPPED IN PEEL E STICK *ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F W W 0 a U w A x h ounniv. as LOT: CREEKSIDE LOT 120 PROJECT* 04321.000 MODEZA 4EAB "16"72—ARIA" GARAGE I;91�ING: LEFT PAGE: WALL ASSEMBLY DETAILS: SUB —BAND Q60 MPH EXP. C DATE: 05/25/18 1 IBCALIM 1/4"=V-011 BIMET "Ail4