Loading...
HomeMy WebLinkAboutFBC ENERGY CONSERVATIONs Planning & Development Services - Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772462-2165 Fax 772462-6443 SCANNED SY Date: FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method St. Lucie County (� (_ Permit#: _ Contractor: �'-'� T RECEIVED APR 16 2019 ST. Lucie County, Permitting o -7 7-1 Lot#: II La's > Address: � ! -7 cobbr. R PIS Construction: Y Post Construction Test ❑ Rough -in Test Test Conditions: Date: l ( I (Q Floor Area (ft2): J I Time: i5 Primary Location of Supply Ductwork lE- Indoor Temperature (F): Primary Location of Return Ductwork Outdoor Temperature (F): Total Leakage Test (Outside) , I Duct Leakage: ❑ Default, 5 (Pa) Proposed On = 0 o Prop. Leak Free `t Test Pressure: o[ Baseline Duct Pressure (optional) (Pa) kc-�cck 0—n Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Pass ❑ Fail Installed Pa p / Total Leakage (cfm): 0 1 2 Total Leakage per 100 sgft: / G6v" CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft. Testing Company r. Company Name: Address: & ��'jM W M eK o ctkr y �v �� � �� I hereby certify that the above Duct Se ling Leakage results demonstrate compliance with 5"h Edition FBC Energy Conservation requirements in accordance with Section R&.2.2. ,� 17 Signature: _ _ �i /CPrint Na e: �gn ��'e ` N icense/Certficate #: MY �o `� 2_ Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Date: Contractor: Job Addrev APR 16 2019 ST. Lucie County, Permitting Construction: (\A) New Construction — Complete ( ) Existing — After Addition House Infiltration Test_Results SLC Climate Zone 2 CFM (50) = 1 5 q Test Date: -1 l Volume = �t ACH (50) = CFM (50) x 60 / Volume = "l Mechanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less If, Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testina Company y� Company Name: C r� 1 Address: (e D(-7 M �i Cwnw,0SIZ'�4 CV, SL-L n, I hereby certify that the above House filtration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Sec�� R402.4.1.2 Climate Zone 2. Signature: `�((,, Printed N License/Certification #: 2Pj- S_d& 2-