HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVITr
r
Planning & Development Services Department
» Building & Regulations Division n 0
Product Review Affidavit (D z
n �
Q M
Building Permit # Owners Name N`IQT,AC .dbc�[t" S. Applicant: •c
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+32.37/-42.62
+50/-60 DP
Ply Gem
Series 4712 Flange
FL 14039.1
Non -Impact
# 10 Wood Screw with sufficient length to achieve 1-1/4' embedment. Requiredanchors: Head (3), Jamb (3)
ullions
N/A
+/-75 DP
Ply Gem
Series 4700 Flange
FL 15264.2
N/A
Use'.'Tapcon with sufficient length to achieve a 1Y..' minimum embedment with 2'/,' minimum edge distance.
ed Glass
+29.65/38.87
+/-55 DP
Ply Gem
Series 4701 Flange
FL 14434.1
Non -Impact
# 10 Wood Screw with sufficient length to achieve l-lW embedment. Required anchors: Head (3), Jamb (3)
ck Glass
Io
N/A
N/A
N/A
N/A
N/A
N/A
N/A
lights
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Sliding Glass Doors
+28.74/-42.62
+/-50 DP
Ply Gem
Series 4780
FL 14634.2
Non -Impact
3/18-Tapson with sufficient length to aahlave 1-1/4•embedment. Requiredanchors: Head/Sni(6), Jamb(5) Each window.
%king Type Doors
+30.64/-30.64
+67.0/-67.0
ThermaTru
3'0k8'D' Smooth Star Rberglass
FL5891.5
N/A
ITW TapoonW. MN Embedment l-W. Min Clearance to edge T. No Clearance to adi—tanchar4% OR ELCO Tepcon IW, Min
9kanch Doors
N/A
N/A
N/A
N/A
N/A
N/A
N/A
G age Doors
+25.91/-31.39
+361-42
Clopay
16X7 Model 73W6
FL16546.4
N/A
Jamb to block on vedicaljamb 1/4'X11/4- min embedded Tepcon. Max spacing of 71/2'end l' OD steelwasher required.
u icane Protection
N/A
+40/-40
Eastern Metal Suplpy
24ga Steel Panels
FL 11964.2
N/A
1/4" Tapcon Anchors, SG Tapcons or 1/4" X 3/4". All points Solid -set Anchors.
f Ventilation
N/A
Roofing Material
N/A
N/A
Tamko
N/A
FL18355.1
N/A
8 nails per shingle. Standard type roofing nab, nail shanks should be 12 gauge wire and minimum heed of 3I0'.
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their use in this :` ucture. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
MAY 7,201.8
Name: JAMES JOSEPH CANTWELL Signature: seal
Design Prof: ARCHITECT Cert. No. AROO 12070 Date. 05/08/18