HomeMy WebLinkAboutLOWER ROOF & FLOORAPPROVED TRUSS ANCHOR BY BUILDER
2X4 MINIMUM TOP AND BOTTOM CHORDS
PLUMB CUT OVERHANG
4-1/16" HEEL HEIGHT
OPM a�
A8
CaNISIVO
LOWER I ROOF AND FLOOR
SCALE: 3/16 = 1'-0" —
ELEVATION "A"
J2
'Z/J
s
I
u
r
a a a qq A
0"0!2 ¢ a eery a a ¢ a a a a a
0
0
M
J2
J4
J6
J8
J8
J8
is
J8
J8
JB
J8
J8
J6
J2
r
s'
r
z
z
9
J2
J4
J6
J8
J8
JS
J8
J8
J8
is r
J8
JS
J8
J81
1.
-
,
MV2
<
a
MV4
rHVEIHJ4
u
A
A
HV1
O
81G
132G
,
n
J2 J2
19'-4" 20 —8
UPPER ROOF
SCALE: 3/16 = 1'-0"
ELEVATION "A"
51
1" CLEARANCE
FOR SHEATHING
8"
BRIG.
I n;
FLOOR TRUSS END DETAIL N.T.S. I TYPICAL TRUSS END DETAIL
FILE COPY
IEWED p REVIEWED AS NOTED
REVISE d RESUBMIT Cl REJECTED/ RESUBMIT
O NOT REVIEWED ❑ FOR YOUR INFORMATION
Submittals are reviewed for conformance with design intent
and general compliance with the Contract Documents only.
Notations 00 Not Authorize Changes to Contract Sum.
Reviews Comments and/of corrections does not relieve the
Conllacfm from Compliance with the Contract Documents The
Contractor a ".pOrsTble lot confirming and correlating all
guantmesdunens,ons, tolerances, clearances. fabrication
processes tcchn'ques and sequences of construction.
compatibn,ty „t materials and materials coordination of their
work with other trades and subcontrac4follmoliance
cc
Honk. m a soft and satisfactory manner awith the Contract Documents.
g141i RA. B. DESIG
N OTE
Trusses shown on this layout are a component part of the buildir
and show truss location. Proper erection, temporary and
permanent bracing design are the responsibility of the building
designer or his engineer . Lateral bracing shown on the individu
truss drawings must be placed during the erection procedur
I I(1R N10 , znrr)
ALL WALLS SHOWN ON
ARE TO BE .. BEARING
_■
: 1 3/4
TRUSS BEARING HEIGHT SCHEDULE
HANGERS TO BE USED
(Simpson) or (Usp)
QA HUS26 ® HUS26
© HGUS26-2 0 THDH26-2
EQ HGUS26-3 EQ THDH26-3
HHUS4,6 6THD46 -
© CONNECTION BY BUILDER
NOTE:
YOUR SIGNATURE WILL ACKNOWLEDGE:
1) AUTHORIZATION FOR FABRICATION.
2) VERIFICATION OF ALL DIMENSIONS, CONDITIONS,
AND TRUSSES. TRUSSES WILL BE MADE IN
STRICT ACCORDANCE WITH THIS PLACEMENT PLAN.
3) RECEIPT AND USE OF "BCSI—Bi Summary Sheet
COMMENTARY and RECOMMENDATIONS for HANDLING,
INSTALLING & BRACING METAL PLATE CONNECTED
WOOD TRUSSES" (TPI).
4) NO BACK CHARGES OR CRANE CHARGES OF ANY
KIND WILL BE ACCEPTED UNLESS SPECIFICALLY
AUTHORIZED IN WRITING BY TRUSS PLANT MNGMT.
SIGNED
TITLE
DATE
All spacing is 24" O.C., except as noted.
All walls shown are bearing, except as noted.
All valleys calculated with sheathing under.
Number of girder plies to be determined by engineering.
DO NOT CUT OR ALTER TRUSSES w/o AUTHORIZATION FROM THIS OFFICE.
Labeling trusses is a service, not a requirement. Engineered
drawings supercede labeling of trusses. It is the responsibility
of the builder to utilize engineered drawings when erecting trusses.
WARNING
ERECTION BRACING IS NOT THE RESPONSIBn1TY OF TRUSS DESIGNER, PLATE MANUFACTURER,
NOR TRUSS FABRICATOR. PERSONS ERECTING TRUSSES ARE CAUTIONED TO SEEK
PROFESSIONAL ADVICE REGARDING ERECTION BRACING WINCH IS ALWAYS REQUIRED TO
PREVENT TOPPLING AND DOMINOING DURING ERECTION; AND PERMANENT BRACING WHICH
MAY BE REWIRED IN SPECIFIC APPLICATIONS SEE 'BCSI—BI Summary Sheet COMMENTARY
snit RECOMMENDATIONS for HANDLING. INSTAWNG a: BRACING METAL PLATE CONNECTED
WOOD TRUSSES' (Tin). TRUSSES ARE TO BE ERECTED AND FASTENED IN A STRAIGHT AND
PLUMB POSITION WHERE NO SHEATHING IS APPLIED DIRECTLY TO THE TOP CHORDS; THEY
SHALL BE BRACED AS SPECIFIED ON THE TRUSS DESIGN.
TRUSSES SHALL BE HANDLED VA711 REASONAIE E CARE DURING ERECTION TO PREVENT
DAMAGE.
TRUSS COMPANY SUPPLIES ONLY TRUSS TO TRUSS CONNECTIONS.
E"1TRUSS COMPANY WILL SUPPLY ALL TRUSS TO TRUSS HARDWARE
O CONNECTIONS FOR REACTIONS UNDER 5000 POUNDS. FOR ALL
7 REACTIONS GREATER THAN 5000 POUNDS, OR SKEWED, NO
F-4 HANGER IS SUPPLIED.
CONTRACTOR SHOULD CHECK ALL REACTIONS FOR PROPER CONNECTIONS.
MWPRS(low-rise)/Wnd ASCE 7-10
Exposure Category : C Bldg Category : 2 Wind Design Velocity : M MPH
Imp. Factor: 1.00 Wind Load Duration Factor : 1.60 Mean Roof Height : 2T-O'
Brian M "y SW Eng 176D51 25% N. Kings frowsy Fat Pierce, FL 34951 (772) 464-4160
'0 N TRUSS (772) 44644-4^160
CONII'ANIF.S, it \ 6"..
2590 N. Kings Highway Fart Pierce, FL 34951
s RYAN HOMES
ormw—
Plan 2195 — Elev. A
Yle MIL WAIN R
3/16"=1'-0" 06/14/18171-;G I 2195—qr
As