HomeMy WebLinkAboutGENERATORRECEIVED
JUN 2 8 Z018
ST. Lucie County, Permittin
• True Power" Electrical Technology
Two Line LCD Multilingual Digital
Evolution'" Controller (English/Spanish/
French/Portuguese)
a Two Transfer Switch Options Available:
100 Amp Pre -Wired Switch or
200 Amp Smart Switch.
See Page 4 for Details.
a Electronic Governor
ENERAC e.
Residential Standby Generators
SCANNED Air -Cooled Gas Engine
BY
Standby Power Rating
Models 006459-0, 006461-0, 006462-0 (Steel - Bisque)-- 16 10 60 Hz
Model 00672 1 -0 (Aluminum - Grey) - 16 kW 60 Hz
Models 006729-0, 006730-0 (Steel - Bisque")'- 2014V 60 Hz
Models 006551-0. 008552-0 (Aluminum - Gray, - 22 60 Hz
• External Main Circuit Breaker, System Status &
Maintenance Interval LED Indicators
GFCI Duplex Outlet
Sound Attenuated Enclosure
• Flexible Fuel Line Connector
o Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Capability to be installed within 18" (457 mm)
of a building*
GENERAC'
c &s QUIFF
LISTED
Nole: CUL certification only applies to unbundled units and units packaged tivith pre -+rued sv,itehus.
Units packaged with the Smart Svifich are UL certified in the USA only.
*Only if located away from doors, windows and fresh air intakes, and unless other vise directed by local codes.
FEATURES
C INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it
doesn't stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose GENERAC POWER SYSTEMS with the confidence that these
systems will provide superior performance.
0 TRUE POWEP17' ELECTRICAL TECHNOLOGY: Superior harmonics
and sine wave form produce less than 5 o Total Harmonic Distortion for
utility quality power. This alloys confident operation of sensitive electronic
equipment and micro -chip based appliances, such as variable speed HVAC
systems.
0 TEST CR17J1 iIA:
PROTOTYPE TESTED NEMA MGi-22 EVALUATION
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY
O SOLID-STATE. FREQUENCY CGPr1FENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads grhakr&00J
voltage regulation at L1%. PLAN REVIEW
n
N
GENERA
SINGLE SOURCE SERVICE RESPONSE from GdBW extencfy�er
network provides parts and service know-how for 6AIL1i_re unit, from
engine to the smallest electronic component.
iPnefeas
u"ENERAC TRANSFER SWITCHES. Long IIIability are
synonymous with GENERAC POWER SYSTEMS.rrfortttis—
confidence is that the GENERAC product line inc0fi1W4 nwn Lancfar
systems and controls for total system compalibilkaw
DA1�
r .ate- �-.r? L. g
oef -
Fs._r� 4 s
i
GENERAC
1120/22 kW
specifications
I GI �-il i G:Oi
mid
006459-0,006461-0,006462- 006729.0,006730-0,
006551-0,006552-0
e
l
Ra{ d Maximum Continuous Power Capacity (LP)
0, 006721-0 (16 kW)
16.000 Watts`
(20 kW)
20,000 Watts`
(22 kW)
22,000 Watts'
Ra'�d hwrimum Continuous Power Capacity (NG)
16,000 Watts'
18,000 Watts*
19.500 Watts'
Rzred Voltage
240
240
240
Ra ad Maximum Continuous Load Current— 240 Volts (LP/NG)
66.6166.6
83.3/75
91.6/81.3
To I Harmonic Distortion
less than 5%
Less than 5%
Less than 5%
P, in Line Circuit Breaker
65 Amp
90 Amp
IGO Amp
P ase
1
1
1
I> mber of Rotor Poles
2
2
2
fjated AC Frequency
60 Hz
60 Hz
60 Hz
Fp wer Factor
1.0
1.0
1.0
f�IaOery Requirement (not included)
Group 26R.12 Volts and 525 CCA Minimum
Unit Weight (Ib/kg)
513/232.7 (Steel);
4481203.2 (Aluminum)
616/234.1
5261238.6
�Jimensions (L x W x H) in/mm
48 x 25 x 2911218 x 638 x 732
ound output in dB(A) at 23 if (7 m) with generator operating at normal load"
66
66
67
ound output in dB(A) at 23 it (7 m) with generator in Quiet -Test" low -speed
60
60
58
xercise mode—
ercise duration
1
f rf�}rie
5 min
5 min
5 min
Type of Engine
GENERAC OHVI V-TWIN
GENERAC OHVI V-TWIN
GENERAC ON V-TWIN
Number of Cylinders
2
2
2
Displacement
992 cc
999 cc
999 cc
Cylinder Block
Aluminum w/ Cast Iron Sleeve
Valve Arrangement
Overhead Valve
Overhead Valve
Overhead Valve
Ignition System
Solid -stale ml Magneto
Solid -slate wi Magneto
Solid-state wl Magneto
Governor System
Electronic
Electronic
Electronic
Compression Ratio
9.5:1
9.5:1
9.5:1
Starter
12 Vdc
12 Vdc
12 Vdc
Oil Capacity Including Filter
Approx. 1.9 gr/1.8 L
Approx.1.9 gV1.8 L
Approx.1.9 ql/1.8 L
Operating rpm
3,600
3,600
3,600
Fuel Consumption
Natural Gas 111/hr (mllhr)
112 Load 193 (5.47) 205 (5.8)
184 (5,21)
Full Load 31218.83) 308 (8.72)
281 (7.96)
Liquid Propane 1131hr (gabitr) [Vhr]
1/2 Load 72.4 (1.99) [7.53] 75.6 (2.08) [7.87]
83 (2.16) 18.16]
Full Load 130 (3.57) [13.531 140 (3.85) [14.57]
127 (3.68) 113.99)
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7'vrdter column (7-13 mm mercury) for natural gas,
10-12' water column (19-22 mm
mercury) for LP gas. For Btu content. multiply R3lnr x 2500 (LP) or 0/hr x 1000 (NG). For Megalcule cordem, multiply m-Air x 93.15 (LP) or m-/hr x 37.26 ING)
i„Oiai:cis
2-Line Plain Text Multilingual LCD Display
Mode Buttons: Auto
Manual
Off
Ready to Ruri/Maintenance Messages
Engine Run Hours Indication
Programmable start delay between 2-1500 seconds
Utility Voltage Lossr'Return to Utility Adjustable (Brownctn Setting)
Future Set Capable Exerciser/Exercise Set Error Warning
RuruAtauTJMa'snterlance Logs
Engine Start Sequence
Starter Lock -out
Smarr Battery Charger
Charger Faulb'hiissing AO :earning
Low Bauery/Battery Problem Protection and Battery Condition Indication
Automatic Voltage Regulation with Over and Under Voltage Protection
Under-Frrquency/Overload/,fepper Overcurrent Prolection
Safety Fused/Fuse Problem Protection
Automatic Low Oil Pressure/High Oil Temperature Shutdown
G:ercrankrOverspeed (@ 72 Hz)/rpm Sense Loss Shuidomi
High Engine Temperature Shutdown
Irdemal FaulVlncorract ;Wiring Protection
Common External Fault Capability
Field Upgradabie Fiim;:are
Simple user interface for ease of operation.
Automatic Start on Utility failure. 7 day exereser.
Start with starter control, unit stays on, If utilitytails, transfer to load takes place.
Slops unll. Power is removed. Control and charger still operate.
Standard
Standard
Standard (programmable by dealer only)
From 140-171 V/190-216 V
Standard
50 Events Each
Cyclic craoking:16 sac on, 7 rest (90 sac maximum duration).
Starter cannot re-engage until 5 sec after engine has stopped.
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
",-mend le tsale t2kin from mt:Irltintof Ire genew.w. So nd levels L'ken from other sides o; the genia'ar may tiehi,h. dep-nA1g on Raflng defift.ton's-Staadbf. Applicable for s ppliing ern-1g-ncy poet to; the dwraMn
of the wirily poe al o aga. tin otarlaad ra(All ratings In arcmdancev.il h e55514, ISe3046 and DC162711. ' NWft tm v.-iM,6 and cuuent are aibJ ct In and fimi,Md by such laGcas as Net 6hLtnagaioul! "W,
aabienl tenperahue-altierde. <englne pool and condition, etc iL? Anrjm pc'rcr declass abot:13.5 pereenttar each 1,000 feet (304.9 me?lst above level: and also r611 dDr= abmrt 1 percanlfor eadi 5 C (10 F) above 16'C 160 F).
16%20/22 kW
GEICIERAC
features and benefits
Zn ine
• enerac (OHVI) design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings
helps the engine run cooler, reducing oil consumption resulting in longer engine life.
• I uiet Test "'
Greatly reduces sound output and fuel consumption during bi-weekly exercise, compared to other brands.
•� Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• lectronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
ull pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life.
Now featuring up to a 2 year/200 hour oil change interval.
rLow oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
High temperature shutdown
Prevents damage due to overheating.
q'I2ncratoP
r Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation
Maximizes motor starting capability.
-Automatic voltage regulation
Regulates the output voltage to =1 % prevents damaging voltage spikes.
• UL 2200 listed
For your safety.
" raoesfer S�vitct�
1 • Fully automatic
Transfers your vital electrical loads to the energized source of power.
•Pre -wired. color -coded conduits
Ensures the easiest, trouble -free installation.
(Pre -wired switches only)
•DPM Technology
Digital Power Management Technology allows for the smart control of two air conditioners without any additional
(Smart Switch only)
items.
• Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
t_vclLiIi-.n Ccntrols
-Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
• Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
-Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
• Utility voltage sensing
Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage.
-Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
• Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up
Ensures engine is ready to assume the load. setpoint approximately 5 seconds.
• Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
-Programmable exerciser
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5
minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and
potentially lower fuel costs to the owner.
• Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
-Electronic governor
Maintains constant 60 Hz frequency.
Unit
-SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up
to 150 mph. Hinged key locking root panel for security. Lift -out front for easy access to all routine maintenance
items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
-Small, compact. attractive Makes for an easy, eye appealing installation, as close as 18" away from a building:
lilstaliaiicn;si�rn
• 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities.
1 EV20/22 W
f i'' red Feattiras
a!'a�, 8b1a on Seel i6 W1 models only
ectric • ally operated, mechanically -held contacts for fast, positive
• Rated for all classes of load,100% equipment rated. bath inductive and
• pole, 250 VAC contactors.
• 0 millisecond transfer time. .
•; ual coil design.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
NEMA 1 (indoor rated) enclosure is standard on the.pre-wired switch.
q Pre -wired 30 foot (9.1 meter) whip to connect to the provided 5 foot pre -
wired whip and external connection box.
Pre -wired 2 foot (0.61 meter) whip, color coded to connect into the
existing electrical panel.
ensions
switch options
Model
006461-0 (16 kW)
No. of Poles
2
Current Rating (Amps)
100
Voltage Rating (VAC)
120/240, 10
Utility Voltage Monitor (Fixed)'
-Pier-up
80%
-Dropout
60%
Return to Utility'
approx 15 sec.
Exercise weekly for 12 minutes'
Standard
UL Listed
Standard
Total of Pre -!wed Circuits
16
No. 15A120V
5
No. 20 A 120 V
5
No. 20 A 240 V
1
No. 30 A 240 V
-
No. 40 A 240 V
1
No. 50 A 240 V
1
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current Cti 250 Volts
10,000
'Function of Evolution Controller
;
Mechanical Dimensions
Height
Width
Oepth
H1
H2
Wl
W2
in
23.5
26A
8.3
12.6
6.3
mm
597
671.7
211
320.7
159.6
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
210-#14
2/0-#14
2/0-#14
Stiiiart 8r11i$Ci1 Fe8(Lf7eS
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages two air conditioner loads with no additional
hardware.
• Up to four more large (120/240 VAC) loads can be managed when
used in conjunction with Power Management Modules (PMM").
• Electrically operated, mechanically -held contacts for fast, clean
connections.
• Rated for all classes of load, 100 % equipment rated, both inductive
and resistive.
• 2 pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• NEMA/UL 3R aluminum outdoor enclosure.
• Main contacts are silver plated or silver alloy to resist welding and
sticking.
-•Note: PMM starter kit is required prior to using the modules.
Dimensions 200 Amps 120/240, to
Open Transition Service Rated
Height Width Depth
H1 H2 F1+1 W2
in 27.24 i 30.0 1 11.4 13.5 7.09
mm 692.0 1 762.4 1 289.0 343.0 1 160.0
w1
W2
Model
005462-0 (16 kW)/006729-0 (20 kW)/006551-0 (22 kW)
No. of Poles
2
Current Rating (Amps)
200
Voltage Rating (VAC)
120/240, '10
Utility Voltage Monitor (Fixed)'
-Picts-up
80%
-Dropout
60%
Return to Utility'
approx. 13 sec.
Exercise weekly for 12 minutes'
Standard
UL Listed
Standard
Enclosure Type
NEMA/UL 3R
Withstand Rating (Amps)
22,000
Lug Range
250 MCM - #6
'Function of Evolution Controller
GENERAG
16120/22 kW
available accessories
Model #
Product Description
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have
00jj463-1
Mobile Link- access to an Internet connection from a PC or with any smart device. You will even be notified when a
change in the generator's status occurs via e-mail or text message.
005819 0
26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R
wet cell battery for use with all air-cooled standby product (excluding PowerPactO).
If the temperature regularly falls below 32 IF (0 °C), a cold weather kit is required to maintain optimal
0 6212-0
Cold Weather Kit battery and ail temperatures. Kit consists of a battery warmer and oil fitter heater with built-in
thermostats.
f] 5621-0
Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical
load you may not need. Not compatible with 50 amp pre -wired switches.
"IKit
05839 0 -Bisque
Fascia Base Wrap Kit* The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers
05666-0 - Gray
(Standard on 22 kW) a sleek, contoured appearance as well as offering protection from rodents and insects by covering the
lifting holes located in the base.
05703-0 -Bisque
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect
05704-0 - Gray
Paint Kit* from future corrosion. The paint kft includes the necessary paint to properly maintain or touch-up a
generator enclosure.
006484-0 -16 kW
�006485-0
Scheduled Maintenance Kit Generac's scheduled maintenance kris provide all the hardware necessary to perform complete
= 20 & 22 kw
routine maintenance on a Generac automatic standby generator.
Completely wireless and battery powered, Generates wireless remote monitor provides you with
006664-0
Wireless Remote Monitor instant status information without ever leaving the house. Not compatible with CorePower or EcoGen
systems.
The PMM Starter Kit consists of a 24 VAC, field installed transformer that enables the use of the 24
006199-0
PMM Starter Kit VAC Power Management Modules (PMMs)and one PMM. The standard controller (without starter kit)
I
can control two HVAC loads with no additional hardware. Not compatible with pre -wired switches.
Power Management Module (50 Power Management Modules are used in conjunction with the Smart Switch to increase its power
006186-0
Amps) management capabilities. It gives the Smart Switch additional power management flexibility not found
in any other transfer switch. Not compatible with pre -wired switches. Note: PMM Starter Kit required.
* Note: Bisque kits are used
in conjunction with steel enclosures. Gray kits are used in conjunction with aluminum enclosures.
r
dimensions & UPCs
Dimensions ai o n ce appmenctte. Refer to installation mamei for a Oct dimai�.crs. DO NOT USEPiESE DIrdENSIONS FOB INSTALLATION PURPOSES.
lv smr
LEFT SIDE VIEW
f47.9 in]
i
i
rF
1226 mm
FRONT VIEW
Model
UPC
006459-0
696471064599
0064610
696471064612
006721-0
696471067217
006729-0
1 696471067293
006730-0
696471067309
006551-0
696471065510
006552-0
696471065527
006462-0
696471064629
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
9.2014 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change r:ithoul notice. Bulletin OK8458-D Printed in U.S.A. GMW14
X -r 0)73�
Automatic'
isfer Switches
•e�x�umusa�,o��
onJ fe21.'n yarn _
Description
GENERAL'
Service rated
Automatic Smart Transfer Switch
with 8 Circuit Load Center
200 Amps, Single Phase
Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'"" or Nexus",
Controller. The 200 amp open transition switch is a single phase service entrance rated configuration.
Standard Features
Service Rated (RTSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA 3R and UL 3R enclosure, with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. The
integrated 8 circuit load center accepts 1" standard, GFCI, AFCI, or tandem circuit breakers from Siemens, Murray, Eaton, and
Square D for the most flexible and cost effective install. Utilizing tandem breakers, the load center can be equipped to support up to
16 individual circuits. All switches are covered by a 5 year limited warranty.
Load Management Technology
Through the use of Digital Power Management technology (DPM), these switches have the capability to manage up to 4 individual
HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with external Smart Management Modules
(SMM), up to 8 more loads can be managed as well, providing the most installation efficient power management options available.
SO
soon
'zoos
!q0 Amps, Single Phase
GENERAC°
Automatic Smart Transfer Switches
All,timing and sensing functions originate in the generator controller
Utility voltage drop -out ....................... <65%
Timer to generator start....................................................................................................5 second factory set, adjustable between 2-1500 seconds by a qualified dealer'
Enginewarm up delay........................................................................................1.......................................................................................................................5 seconds
Standbyvoltage sensor.................................................................................................................................................................................................. 60% for 5 seconds
Utilityvoltage pickup.........................................................................................................................................................................................................................>80%
Re -transfer time delay...............................................................................................................................................................................................................15 seconds
Enginecool -down rimer ............................................................................................................................................................................................................60 seconds
Exerciser.................................................................................................................................................................. 5 minutes weekly, adjustable to bi-weekly or monthly
The transfer switch can be operated manually without power applied.
'When used in conjunction with units utilizing Evolution`" controls
1 —_
�,ilodel
RTSW2O0A3F
F�mps
200
Voltage
12O/24O,1H
(Aad Transition Type
utomatic)
Open Transition
Service Rated
*losure Type
UL Type 3R
bl- Rating
UL
Withstand Rating
(Amps)
10,000
22,000'
Lug Range
#1 - 300 MCM AI/CU 75 C
Integrated Load Center
18
used with 1"Siemens or Murray Breakers
Dimensions,
Model
RTSW20OA3F
Height
CmJmm)
H7
48.0/1419.2
H2
42.9 / 1090
Width
(InJmm)
w1
22.5 / 571.5
W2
16.7 / 424
Depth (inJmm)
10.3 / 261.6
Weight (IbsJldlos)
85 / 38.6
GENERAC' Generac Power Systems, Inc. • S45 W2929O HWY. 59, Waukesha, WI 53189 • generac.com
02016 Generac Power Systems, Inc. All rights reserved. M specifications am subject to change wthout notice. Bulletin 100000079BS 1212116