Loading...
HomeMy WebLinkAboutPRODUCT APPROVALSCANNED 8V St. Lucie county BCIS'Home 1 Log In i User Registration Hot Topics I Submit Surcharge Stats & Facts bpr a (R Product Approval pprr,,rr � USER: Public User rc�rar�� Pmduct Approval Menu > Product or Aoolication Search > Application List -FY Search Criteria ABPJL"out Ab0i1T DBPB, tl"'R 601woux . C0tlrACT DB;?it, Refine Search Code Version 2017 FL# 16027 Application Type ALL Product Manufacturer ALL, Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for.use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL €L# Type Manufacturer Validated By S a us FL16027-112 Revision Tri-Built Materials Group, LLC Category: Roofing Subcategory: Modified Bitumen Roof System John W. Knezevich, PE (954) 772-6224 Approved History -„ppmvee py uorK. , ppmvai oy uorn snap pe rewewea ana raoneu oy the PUL ana/or the c.omm651on p necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850.487-1824 The State of Florida Is an AA/EEO employer. Cogyrieht 2007-2013 State. of Florida.::. Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail addressreleasedin response to a public -records request, do not send electronic mail.to this entity. Instead, contact the office by phone or by traditional mail. If you, have any questions, please. contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2022, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a -personal address, please provide. the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dick here Product Approval Accepts: ® ®® iOtfd Credit Card Safe RECEIVED JUN' '2'8 2018 Permitting pepartment St. Lucie County FILE COPY F*110 \,e TRINITY I ERD EVALUATION REPORT, TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800) 516-1485 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203) 262-9245 Evaluation Report A42970.10.12-112 FL16027-RZ Date of Issuance:10/23/2012 Revision 2: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated. for compliance with the 6t" Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that:relate to the product change. ,Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced. Quality Assurance documentation changes. Tririityl ERD requires a complete review of this Evaluation Report relative to updated Code.requirements with each Code Cycle. . ADVERTISEMENT: The, Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection atthe job site at the request of the Building Official. This Evaluation Report consists of pages:) through 4, plus a 26-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/25/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC: d/b/a Trinity.) ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products°it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.. LL S. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen; P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used forpermitting or design guidance unless retained specifically for that purpose. (TT�INITYJERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: TRI-BUILT Modified Bitumen Roof Systems, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section PropertV Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R! 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD:(TST6049) Physical Properties, 033960.12.10. 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) Physical Properties. P45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 300,1334 02/15/2000 FM Approvals (TST1867) FM 4470 300085.7 01/12/2000. FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 Exterior Research and Design, LLC. Evaluation Report A42970.10.12-R2 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL16027-112 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 2 of 4 EntitV FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) PRI (TST5878) PRI (TST5878) PRI(TST5878) PRI (TST5878) Miami -Dade (CER1592) Miami -Dade (CER1592) UL LLC (QUA9625). UL LLC (QUA9625) UL LLC (QUA9625) 4. PRODUCT DESCRIPTION: Examination FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical Properties Physical Properties Physical Properties Physical Properties HVHZ Compliance Proposal'for Review Quality Control Quality Control Quality Control Reference 3023458 3030668 3032172 PUSA-062-02-01 PUSA-061-02-02 PUSA-064-02-02 PUSA-062-02-02 Various NOAs 10-0823 MI -Agreement 'M L Correlation, R27202 Service Confirmation, R14571 \I TRINITY I ERD Date 07/18/2006 09/12/2007 06/12/2009 12/04/2007 01/28/2008 02/27/2008 12/04/2008 Various 10/12/2010 02/27/2012 08/20/2012 Exp.10/06/2018 This Evaluation Report covers TRI-BUILT Modified Bitumen Roof Systems installed in accordance with TRI-BUILT Materials Group, LLC published installation instructions and the Limitations / Conditions of Use herein. The following membranes make up the subject systems. Table 1: R'oll-GoodslorTR1=BUILT Modlfled ,Bitumen .Roof Systems Type Product Specification Reference Grade Type SBS Membranes TdBuilt SA SBS Base ASTM D6163, Table 2 S I TriBuilt SBS Granular ASTM D6164 G I TriBuilt SA SBS Cap ASTM D6164 G I APP Membranes TriBuilt APP Smooth ASTM D6222 S I TriBuilt APP Granular ASTM D6222 I G I TriBuilt SA APP Cap ASTM D6222 I G I S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this EvaluationReport, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This EvaluationReportis not for use in FBC HVHZ jurisdictions. 5.3 Refer to a. current Approved Roofing Materials. Directory for fire ratings.of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance With FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. Exterior Research and Design, I.I.C. Evaluation Report A42970.30.12-R2 Certificate ofAuthorizotlon H9503 6'EDITION (2017) FBC NON-HVHZ EVALUATION FL16027-R2 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 3 of 4 v TRINITY JERD 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTNI E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and 'installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.9(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 6. INSTALLATION: 6.1 TRI-BUILT Modified Bitumen Roof Systems shall be installed in accordance with. TRI-BUILT Materials Group, LLC published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL LLC —QUA9625,• (314) 578-3406, k.chancellor@us.ul.com - THE 26-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42970.10.12-R2 Certificate ojAuthorizotion #9503 6'" EDITION (2017) FBC NON-HVH2 EVALUATION F1.16027-112 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2.,09/25/2017 Page 4 of 4 TRIN"I ERD I APPENDIB 2:YATTACHNIENTREQUIREMENTS.FOR WIND UPLIFT RESISTANCE ' Table Deck Application Type, Description Page IA-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation,: Bonded Roof Cover 4 SA-2 Wood New, Reroof (Tear -OM or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 11) Wood New, Reroof (Tear=Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 1E-1 Wood New or Reroof (Tear -:Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 1E-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 ;1F' _ —Wood._, ^ ___ _ _ _ . __,_ —New: or Reroof.(Tear=Off) -. -_ - ,_- f Non -insulated; Bonded Roof;Cover 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 10 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 SB CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded'Roof Cover 23 68 Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24 6C Gypsum 'New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 7B Various Recover F Non -Insulated, Bonded Base Sheet Bonded Roof Cover 26 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: D Wood: Minimum 0.75-inch penetration. t Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505,1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover. Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization R9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26 TRINITY I ERD Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete may be substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby, the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and. structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. D HA (HA): Full coverage at 25-30 Ibs/square. D Dow INSTA STIK Ctuik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons,l2-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA); Continuous 0.25 to 0.5-Inch wide. ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart orSpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive &.Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,l2-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are Installed In ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. in no case shall these values be used to 'Increase' the MOP listings in the tables; rather if MOP listing below meets or exceeds that listed for a particular system In the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed In the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) D OMG OlyBond 500 (OB500): - MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) D OMG OlyBond 500 (OB500); MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoarn II) D ICP Adhesive & Sealants CR-20. MDP =117.5 psf (Min.1.0-inch thick) S. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data.Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be In accordance with ANSI%SPRI FX-1 orTesting Application Standard TAS 105. 12. For existing, substrates in a bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond. performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications. using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC'is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization H9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 2 of 26 `J 1 R1NITi I ERD 15. Unless otherwise noted, refer to the following references for bonded base; ply or cap sheet applications. TA6LEl TRI BUILTRooF:CovEas Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type II (Base and Ply sheets, Asphalt -Applied) HA at 20-40 Ibs/square Ply FBC Approved ASTM D2178, Type IV or VI SBS-AA (SBS,: Asphalt -Applied) Cap Ply TriBuilt SBS Granular HA at 20-40 Ibs/square SBS-TA (SBS, Torch -Applied) Cap Ply TriBuiltSBS Granular Torch -Applied SBS-SA Base Ply TriBuilt SA SBS.Base (SBS, Self -Adhering) Self -Adhering Cap Ply TriBulltSA SBS Cap APP-TA Base Ply or Ply TriBuiltAPP Smooth (APP, Torch -Applied) Torch -Applied Cap Ply TriBuilt APP Smooth, TriBuilt APP Granular APP-SA (APP, Self -Adhering) Cap Ply TriBullt SA APP Cap Self -Adhering 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP listings below vs. those In Table 3A applies: VAPOR BARRIER QPTION5; 5 TRUCTURALCNC ORETE:DECI('ADHERE0,INSU(ATIONPERTABLE3A' Option N Primer Vapor Barrier Insulation Adhesive MDP (psq Type Attach VB-1. ASTM D41 TriBuilt SA SBS Self -Adhering Inta-Stik or CR-20,12-inch o.c. -60.0 VB-2. ASTM D41 TriBuiltSA SBS Cap Self -Adhering Insta-Stik, 12-inch o.c. -75.0 VB-3., ASTM D41 TriBuilt SA SBS Cap Self -Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157:5 VS-4. ASTM D41 TriBuilt SA SBS Cap Self -Adhering CR-20,12-inch O.C. -270.0 VB-S. ASTM D41 TriBuilt SA SBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20, 12-inch o.c. 290 0 17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 181 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-112 Certificate of Authorization 49503 6i° EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2:'09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26 tl TRINITY 1 ERD . .. TABLE 14-1: 'WOOU DECKS —NEW CONSTRUCTIQN oe RERO' QF (TEAR OFF) > SYSTEM:, PEA=2 MECHANICALLY ATTACHED ANCHORS EET, BONDED INSULATION, $ONDED.ROQF COVER System Deck Anchor Sheet Base Insulation Top Insulation Rooftover (Note 15) loop No. (Note 1) Type Fasteners Attach Type Attach Type Attach I Base Ply Ply Cap Ply (Psf) Min.0.25-inch Dens Polyglass G2 Base, 8-Inch o.c. in 4- Deck, Dens Deck Prime, Min. 19/32- CertainTeed.Glasbase, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC SECUROCK Gypsum - inch plywood Firestone MB Base, JM Inch diameter inch o.c. in Approved, Fiber Roof Board, Min. (Optional) SBS-AA, W-1 at max. 24- Perma-Ply Tamko tin caps with 11 three, equally ASTM C7289, HA 0.75-inch FescoBoard HA BP -AA BP AA SBS-TA, -60.0 inch spans Glass Base or ga. annular ring spaced, type II polyiso- (homogeneous) or min. APP=TA GAFGLAS #75 shank nails staggered cyanurate 0.5-inch Structodek center rows High Density Fiberboard Roof Insulation Polyglass G2 Base, 8-inch o.c, in 4- Min.19 32- Certain7eed Glasbase, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC Min. 0.25-Inch Dens (Optional) ( p ) SBS-SA, W 2 Inch plywood Firestone MB Base, JM Inch diameter tin caps with 11 inch o.c. in three, equally Approved, ASTM C1289, HA Deck, Dens Deck Prime, HA SBS-SA One or more SBS- APP-SA, 60.0 at max. 24- Perma-Ply 28, Tamko ga. annular ring spaced, type II polyiso- SECIJROCK Gypsum- SA or SBS-TA or inch spans P Glass Base or shank nails staggered cyanurate Fiber Roof Board APP TA APP-TA GAFGLAS #75 center rows 6-inch o.c. in 4- Min.19/32- 32 ga., 1-5/8- inch lap and 6- Min. 2-Inch D-IS, OB500, wood inch I Polyglass Elastobase inch diameter inch o.c. in ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens D-IS, SBS-AA, W-3 plywood or Polyglass tin caps with 12 four, equally H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, BP -AA (Optional) SBS-TA, -60.0• max. max. Elastobase PolyShield ga. annular ring spaced, CG, fastener or SECU ROCK Gypsum- CR-20 or BP -AA APP-TA In In spannss shank nails ,staggered Multi -Max FA3. rows, 7-inch Fiber Roof Board M-OSFA center rows or ENRGY-3 cc Min. 19 32- / 32 ga., 1-5/8- 6-inch o.c. in 4- inch lap and 6- Min. 2-Inch D-IS, OB500, (Optional) ( P ) inch plywood P Polyglass Elastobase Inch diameter inch o.c. in ACFoam il, III, H- CR-20 or M- atop (Optional) Additional D-IS, One or SBS-SA, APP-SA, W-4 at max. 24- or Polyglass Elastobase Poly tin caps with 12 ga. annular ring four, equally spaced, ShieldH-ShiC Shield CG, fasteOSFAner fastener layers of base insulation CR500, CR-20 or SBS-SA more SBS- SBS-TA or -60.0' Inch spans shank nails staggered Multi -Max FA3 rows, 7-inch M-OSFA SA or SA or APP TA center rows or ENRGY-3 oc Exterior Research and Design, I.I.C. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-112 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 4 of 26 V I RINITY I ERD TABLE SA-2:. WOOD DECKS'=.NEW CONSTRUCTION,;REROOF.(TegR OFe) oR RECOVER SYSTEMTYPEA 2:'MECHANICAL4YATTACHED.ANCHOR;SHEET,,BONDEDINSULATION BONDED -ROOF COVER'. System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (psi) 12-inch o.c. in 4- Min. 0.25-inch Dens Deck, MIn.19/32- Pol glass Y OMG Flat inch lap and 12- (Optional) FBC Dens Deck Prime, SECUROCK wood l Inch plywood Elastobase or Bottom Plates inch o., , In two c Approved, Gypsum -Fiber Roof Board, (Optional) SBS-AA, SBS- W-5 at max. 24- Polyglass (square)withequally spaced, ASTM C1289, HA Min. 0.75-Inch FescoBoard HA BP -AA BP -AA TA, APP-TA -60.0 inch spans Elastobase Roofgrip #12 staggered center type 11 polyiso- (homogeneous) or min. 0.5- Poly cyanurate inch Structodek High Density rows Fiberboard Roof Insulation Min.19/32- Polyglass OMG Flat 12-inch o.c. in 4- inch lap and 12- (Optional)'FBC (Optional) inch plywood Elastobase or Bottom Plates inch o.c. in two, Approved, Min. 0.25-inch Dens Deck, One or SBS-SA, APP- W-6 at max. 24- Polyglass (square) with equally spaced, ASTM C1289, HA Dens Deck Prime, SECUROCK HA SBS-SA more SBS- SA, SBS-TA 60.0 Inch spans Elastobase Roofgrip #12 staggered center type II polyiso- Gypsum -Fiber Roof Board SA or APP- or APP-TA Poly cyanurate TA rows ,• ; TABLE;IB WOODDECKS-NEWCONSTRUCTION,.REROOF,(TFAR OFF)oRRECOVER ., SYSTEM TYPE B:' MECHANICALLYATTACHED BASE INSULATION,BONDED TOP.I NSULATION, BONDED ROOF COVER 1.Top System Deck (Note 1) Base Insulation Layer Insulation Layer Roof Cover (Note 15) MDP Type Fasteners Attach Type Attach Base Ply Ply Cap Ply No. (psi MIn.19/32-inch Min.1.5-inch Dekfast Hex with Min. 75-inch FescoBoard 0. (Optional if (Optional if using W-7 plywood at max. 24-inch p Y ENRGY 3, H-Shield Dekfast #12 or 1 per 2 ft (homogeneous) or min. 0.5-inch. HA using AA Ply) AA Base) One or SBS-AA; SBS-TA, -60.0 spans or Polytherm MP-3 with 7ruFastDP 1.33 Structodek High Density. Fiberboard BP more BP=AA or APP-TA Roof Insulation APP TA Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for F1.36027-112 Certificate of Authorization #9503 e" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 5 of 26 r�'Q JI KINITYIERD TABLE iC WOOD DECKS;=NEW C'0NSTR1UCTION,:REROOF (TeAa-OeF) oa RECOVER '- SYSTEM TYPE CE,MECHANICALLY'ATTACHED INSULATION, BCINDED'ROOF COVER • 2 System Deck (Note 1) Base Insulation Top Insulation layer Roof Cover (Note 15) MDP Type Fasteners Attach Base Ply Ply Cap Ply No. Layer Y (pso Min.19/32-inch (Optional) Min.0.5-inch Strudodek High Density Dekfast Galvalume (Optional if (Optional if using AA W-8 plywood at max. One or more layers, Fiberboard Roof Insulation or min. 0.25- Steel Hex with 1 per 1.33 z using AA Ply) Base) One or more BP -AA SBS-AA, SBS-TA, APP- -82.5 24-inch spans any combination, inch Dens.Deck, Dens Deck Prime or Dekfast #12 DP ft BP -AA or APP-TA TA loose laid SECUROCK Gypsum -Fiber Roof Board (Optional) Dekfast Galvalume W-9 Min.19/32=inch plywood at max. One or more layers, Min.1.5-inch ENRGY 3, H-Shield or Steel Hex with Dekfast #12 DP or 1 per 1.33 SBS-SA (Optional) One or more SBS-SA, APP-SASBS- , -82.5 24-inch spans any combination, Polytherm TruFast MP-3 with ft a S.BS-SA or APP-TA TA or APP-TA loose laid TruFast DP TABLE ID WOODDECKS—NEW CONSTRUCTION, REROOF (TEAR OFe) oa RECOVER :. SYSTEM TYPE 6: PRELIMINARILY ATTACHED INSULATION, ATTACHED'BASE-SHEET,.'60NDtD ROOF CC4 System. Deck (Note 1) Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP Type Attach Base Fasteners Attach Base Ply Cap Ply No. (Psf) Polyglass Elastobase, Polyglass OMG Flat Bottom Plates Min.19/32-inch One or more layers, Prelim. Elastobase Poly, Polyglass G2 Base, (square) with Roofgrip, 12-inch mc. in 4-inch lap and 12- (Optional) One SBS-AA, W-10 plywood at max. any combination Attached CertainTeed Glasbase, Firestone MB #14, Dekfast Hex with inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -52.5 24-inch spans Base, JM Perma-Ply 28, Tamko Glass Dekfast #14 or TruFast staggered center rows or APP-TA APP-TA Base or GAFGLAS #75 MP-3 with TruFast HD Min. 19 32-inch / One or more layers, Prelim. Polyglass Elastobase or Polygiass Dekfast Hex with Dekfast 12-inch o.c. in 4-Inch lap and 12- One.or more SBS-SA, APP-SA, W-11 plywood at max. P Y any combination Attached Elastobase Polywith poly top surface #14 or. TruFast MP-3 with inch o.c. in two, equally spaced, SBS-SA SBS-TA or -52.5" 24-inch spans TruFast HD staggered center rows APP-TA W-12 Min. 19/32-inch at max. One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA, plywood P YN 24-Inch any combination Attached Elastobase Poly (square) with Roofgrip #12 inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -60.0 s spans P staggered center rows or APP-TA APP TA W-13plywood'at Min.19/32-Inch max. One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. In 4-inch lap and 12- One or, more SBS-SA, APP-SA, 24-inch spans any combination Attached Elastobase Poly poly top surface (square) with Roofgrip #12 inch o.c in two, equally spaced, SBS-SA SBS-TA or 60.0• staggered center rows APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-112 Revision 2: 09/25/2017 Appendix 1, Page 6 of 26 Q ,-"r 10 TRINITY I ERD RABLE IE-1s WOOD DECKS— NEW CONSTRUCTION Oa REROOF.,(TEAR OFF): C SYSTEMTYPE Ed;:NON INSULATME ED; HANICALLYATTACWEDBASESHEET; BONDED ROOF COVER' ' System Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP No. Base Fasteners Attach. Base Ply Cap Ply (Psf) Min. ISM -inch W 14 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c, at 2-inch lap and 18-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA 'i5.0 * Inch spans equally spaced, staggered center rows APP TA or APP TA Min. 15/32-inch W-15 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-Inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA 52:5 inch spans equally spaced, staggered center rows APP-TA or APP TA Min.19/32-inch Polyglass Elastobase, Polyglass Elastobase (Optional) One or W-16 P I ood at max. Poly, Polyglass G2 Base, CertalnTeed 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. In 4-inch lap and 8-Inch o.c. in three, more BP -AA or SBS-AA, SBS- 60.0 24 inch spans Glasbase, Firestone MB Base, JM Perma- with 11 ga. annular ring shank nails equally spaced, staggered. center rows TA, APP-TA Ply 28, Tamko Glass Base or GAFGLAS #75 APP-TA W-17 Min.19/32-inch plywood P at max. Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 87inch o.c. in three, (Optional) One or SBS-SA, APP- 24-inch Elastobase Poly with poly top surface with 11 ga. annular ring shank nails equally spaced, staggered. center rows more SBS-SA or SA, SBS-TA or -60.0 spans APP-TA APP-TA Min. 15/32-inch W-18 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-Inch lap and.6-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA -90.0 Inch spans equally spaced, staggered center rows APP-TA or APP TA W-19 Min.19/32-inch plywood at max. y Polyglass Elastobase or Polyglass 32 ga.,1-5/8-inch diameter tin caps 4-Inch o.c. in 4-inch lap and 4-Inch o.c. irtfour, (Optional) One or SBS-SA, APP- P 24-inch Elastobase Poly with poly surface with 11 ga. annular ring shank Halls. equally spaced, staggered center rows more SBS SA or SA, SBS-TA or 97.5 spans P APP-TA APP-TA Mina 15Inch V1l-20 at max plywoodd at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three, (Optional) BP -AA or SBS-AA, SBS-TA -SO5.0 Inch spans equally spaced, staggered center rows APP-TA or APP-TA W-21 Min.19/32-inch at max. Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional),One or SBS-AA, SBS- plywood 24-inch Elastobase Poly with 11 ga. annular ring shank nails equally spaced, staggered center rows more BP -AA or TA, APP-TA -112.5 spans APp TA Min.19/32-inch 32 ga., 1-5/8-inch diameter tin caps SBS-SA, APP- W-22 I ood at max. P yw Polyglass Elastobase or Polyglass with 11 ga. annular ring shank nails. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or SA, SBS: TA or -112.5 24-inch spans Elastobase Poly with poly top surface Note; Tin caps are to be primed with equally spaced, staggered center rows more APP TA ppp TA ASTM D41 primer. Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-112 for FL16027-R2 Certificate of Authorization #9503 6n' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-2485 Appendix 1, Page 7 of 26 TRINITY I ERD :. . TABLE 2E 2 WOOD DECKS NEW.CONSTRUCTION; REROOF (TEAR.OFFpOR RECOVER >• ; . - : `- YSTEMTYPE E.. NON INSULATED,:MECHANICALLYATTACHED'RASE SHEET,:BONDED ROOF COVER System Deck (Note 1} Base Sheet Roof Cover (Note 15) MDP Base Fasteners Attach Base Ply Cap Ply No. (PsD MIn.19/32-inch Polyglass Elastobase; Polyglass Elastobase Poly, PolyglassG2 Base, CectainTeed OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or SBS AA, SBS- W 1 plywood at max. Glasbase, Firestone MB Base, JM Perma- Roofgrip #14, Dekfast Hex with Dekfast #14 o.c, in two, equally spaced, staggered more BP -AA or TA, APP-TA -52.5 24-inch spans Ply 28, Tamko Glass Base or GAFGLAS #75 or TruFast MP-3 with TruFast HD center rows APP-TA W-2 Min. 19/32-inch plywood at max. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 orTruFast MP- 12-inch o.c. In 4-inch lap and 12-inch in qually spaced, staggered One or more SBS- SBS-SA, APP- SA, SBS TA or -52,5* 24-inch spans Elastobase Polwith oltosurface y pyp 3 with TruFast HD center rows center rows SA .APP-TA Min.19/32-Inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-Inch o.c. in 4-Inch lap and 12-Inch (Optional) One or SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o.c, in two, equally spaced, staggered more BP -AA or TA,APP TA -60.0 24-inch spans center rows APP-TA W-4 Min. 19/32-inch plywood at max. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c, in flinch lap and 12-inch o.c. in two,.equally spaced, staggered One or more SBS- SBS-SA, APP- SA, SBS-TA or 60.0 24-inch spans Elastobase Poly poly surface Roofgrip #12 center.rows SA APP-TA TABLE 1F :WOOD DECKS —.NEW CONSTRUCTION OR RERCIOF (TEna OFF), ; i •• „ ,:.. , _ .. TED, BONDED`ROOF COVER. SYSTEM TYPE F. NON 1NSULA ;. System Deck Primer Roof Cover (Note 15) MDP Joint Treatment Base Ply Ply Cap Ply No. (Psf) W 54: Min..15/32-inch piywocd'+i at` 24.Inch,spa.ns. `(Optional).ASTM.D41,� None_;, 'SBS-SA o(OpUon'al);SBS SAWr ; "AP ; SBS-SA,.APP- SA;.SBS-TA— max. _ > PTA._. or APPTA_i W 6 Min. 15/32-Inch plywood (Optional) ASTM D41 Plywood Joints are covered with 4-inch wide strips of TriBuil,t SA TriBuilt SA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA 9T5 at.max. 24-inch spans SBS Base, rolled Into place to create continuous. bond. APP-TA or APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization 49503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26