Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLOWER DOOR TEST FORM
SCANNED I/ go BY St. Lucie County <_ Planning & Development Services Building &Code Regulation Division 2300 Virginia Ave, Rm 201 ....., :_ Fort Pierce, FL 34982 Phone: 772-462-2165 Fax: 772-462-6443 BLOWER DOOR TEST FORM �•�-��-���-��•�<���House�Infiltration�TestCertification,..- �- ��•_-- - - • ��-� � - ,� Prescriptive and Performance Method te• a-��-(9 Permit#: l��`? -c3oo5� ntractor: +t om -es 3 Address: f5S 1 �e 0' r—(a ' C( nstruction: ( �(1lew Construction — Complete ( ) Existing — After Addition House Infiltration Test Results sLC Climate Zone 2 CFM (50) = 1 q q Volume = .0 ACH (50) = CFM (50) x 60 / Volume = 5 41- 1 —1 Passing results must be & ACH t50) or less Test Date: 0azz "19 11e5anical Ventilation required less than 3 ACH ass ( ) Fail BC, Energy he building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per our in Climate Zone 1, 2 and 3 air changes per hoer in Climate Zones 3 through 8. Testing shall be conducted with a lower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in ection 553.993(5) or (7), Florida Statutes or individuals jj%^ensed as set forth in Section 489.105 (3)(f), (g) or (i) or an pproved third party. A written report of the results of the tt st shall be signed by the party conducting the test and rovided to the code official. Testing shall be performed at any �`ime after creation of all penetrations of the building hermal envelope. ,C, Residential here the air infiltration rate of a dwelling unit is less than 3 air changes per hO ur when tested with a blower door at a essure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florl a Building Code, Energy Conservation e dwelling unit shall be provided with whole -house mechanical ventilation in accordal'?ce wiL h Section M1507.3. pany Name: 15 Lightyears INC Address: 776 Bennet Drive Longwood FI 32750 hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation =ouirements in acquLdance wit ion R402.4.1.2 Climate Zone 2. ignature: rinted Name: se/Certification #: 2ev'/r1At6-7 FILE COPY ,:.,.:. ._.:...... ,...:_..:: Ianning.&.Development,Services:.:,. _.....:.. �ilding &.,.Code Regulation Division „ 2300 Virginia Ave, Rm 201 ,• Fort Pierce, FL 34982 : .. ,. 772462-2165 Fax 772462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method AS c �02 —� __.....Pit.#:. 11 0_1 0005 CI!ontractor. `C Y.� �11-C. Address: �� <kcLnd L c,�� Ionstruction: ost Construction Test o Rough -in Test I„ eo Test Conditions: Date: 2-ZZ-1 `) Floor Area (ft2): ) cis — Time: Z "go Primary Location of Supply Ductwork - Indoor Temperature (F): -),9 Primary Location of Return Ductwork Outdoor Temperature (F): 15 Leakage: ❑ Default ❑ Prop. Leak Free 66posed On = © - osJ Pressure: (Pa) line Duct Pressure (optional) (Pa) 52 Press. (Pa) Flow Ring Fan Press Flow (cfm) Results.-XfPass ❑ Fail Installed Pa Total Leakage (cfm): �f Total Leakage per 100 sgft: 2. sh CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft. vu wauv 15 l k4-'�ec'r-5 Name: ,i Address: 77 r certify that the above D ct Se Leakage results demonstrate compliance with 51h Edition FBC Energy Conservation requirements in accordance with R403�2..� • re: Name:��c''"1 �J S « License/Certificate #: �r Al AR-2 FILE COPY ficate of Achievement THIS ACKNOWLEDGES THAT Aaron Overholt HAS MET THE STANDARD REQUIRED BY RESNET, AS A CERTIFIED RATING FIELD INSPECTOR 2GNAB7 Certification Date: 08/07/2018 Certification Expires: 08/07/2021 Tim Smith, RESNET Quality Assurance Designee RESNET QA Provider # (1998-199)