HomeMy WebLinkAboutPRODUCT APPROVAL8
Florida Building Code Online
SCANNED
Professional Regulation
BY
BCIS Home Log In {User Registration { HotTopia SubmttNSur�c711 rg 8 �a FDa { Publications i FBC staff BCIS Site Map { unks I Search {
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application Us[ > Application Detail
FL # F1_10674-1113
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Owens Corning
One Owens Coming Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscoming.com
Greg Keeler
greg.keeler@owenscoming.com
Mel Sancrant
1 Owens Coming PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
FILE COPY
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert J.M. Nieminen
PE-59166
UL LLC
05/16/2020
John W. Knezevich, PE
4' Validation Checklist-.Hardcopy Received
FL10674 R13 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard
ASTM D3161
ASTM D3462
ASTM D7158
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2016
2010
2011
1/2
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
10/10/2017
Date Validated
10/11/2017
Date Pending F8C Approval
10/15/2017
Date Approved
12/12/2017
Summary of Products
r ,
FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge shingles
Shingles and Starters
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.pdf
Verified By: Robert 1. M. Nieminen PE - 59166
Design Pressure: N/A
Other: Refer to ER, Section S.
Created by Independent Third Party: Yes
Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.odf
Created by Independent Third Party: Yes
Bacr Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund. Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850AS7.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S.,
please click bgre .
Product Approval Accepts: -�
I�l ®ccr—
Credit Card
Safe
2/2
v I RINIIY I ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 037940.02.12-118
FL10674-R13
Date of issuance: 02/06/2012
Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20.3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has'been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2,6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/09/2017_ This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Q
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the a Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Entity
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-112453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Devonshire"' are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition* Duration, Duration* Premium Cool, TruDefinition' Duration® Designer Color
Collection, TruDefinition* Oakridge , Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip & Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge"" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-Rg
CerWcoteofAuthor&AVon#9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
f
TRINITY J ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vaw = 150 mph (V„ n = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Va,d =150 mph (Vah =194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D71SS applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 6143203, per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using.
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuardo HP shingles require minimum six (6) nails per shingle.
➢ Devonsh)re'"shingles require minimum six (6) nails per shingle,
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Felt undedayment
j Deck
Sell -adhered
WeatherLock°
c. undedayment
Drip
Drip edge
D
Nails located
2 =3" from eave
Install first
Self-sealing adhesive
Starter Stri
positioned along eave
shingle wh \
6" removed Starter Strip shingle
overhangs eaves and rakes 15 41"
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-RB
CerNflcate ojAuthoriration #9503 GP EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2027
Page 3 of 8
91r, Minimum Nailing — rlassir®& Sunreme:
Normal Mansard or Area porn
Wind Areas High Wind desvonos y
Area pare vientos normafes Areas vientos fuertes
tr tr
6•Exposure '
ExposioiSn
6.2.7 Minimum Nailing— Berkshire®:
Seatam strip
La tira de s0ador
8 Yt" 9 Yt" I 9 Yt
t•
1
Standard Fastening Pattem
QOTRINITYIERD
Normal Mansard or Area porn
Wind Area' High Wind doamnes y
Area porn vientos normates Areas Wantos fuartas
tzt ut
6 6i8" Exposure
Exposicrdn
Seaiont strip
La tlra de seDador
8 th" awl
� T•
r
r
6-Nail Fastening Pattern
Sealant strip
La tkra do SOWN
1" 8 YiN 8Yt' 8 Yf 8 Yf
t"
r- -
r
Asphaa roofing cement
Cemlo de retbo do astafto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION FI.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8: 20/09/2017
Page 4 of 8
- QOTRINITYIERD
6.2.8 Minimum Nailing — Devonshir6l:
1_ 711 81 8" 8" 7" I 1°
ri
a.,ms
exposure Sealant location
Expodtibn de 5518 pull; U61tadb del seliador
Standard 6-Nail Fastening Pattern
,r
Nails
sx• �:•
Ten V Spots of Asphalt Roof Cement
Mansard or Steep Slope Fastening Pattern
•
6.2.9 Minimum Nailing — Duration®, TruDefinition• Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
4-Nail Fastening Pattern
ftMNWWfXA xiromwwmm
N7tl.lyplal
•�..� smna� •. a mw+w • o.F. wevo •
6.1/A•
6318^
.o.a"
Standard Fastening Pattern
"all Fastening Pattern
SuieNYl9fa�eJnp maaMCih
%Na47ypY�1
1" 1r / 1r 1"
p.,�s.am • �m.o i1 •o�c�as..e+no •
6.1N"
6dld•
w.o•
F1 F] EU-
Exterior Research and Design, I.I.C.
Certijicote ofAuthoritotion #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION
Owens Coming Asphalt Roof Shingles
6-Nail Fastening Pattern
Evaluation Report 037940.02.12-118
FL10674-R13
Revision 8:10/09/2017
Page 5 of 8
(TTRINITYIERD
6.2.1 Minimum Nailing —TruDeBnition'Oakridge®, Oakridge®:
4 Nail Pattern
Esquema con 4 davos
1' 1'
—nI 14— rr --*I
5 51r Exposure Nails 5 5ff Exposure
Fxposid6nde6618prdg. Clams Fxpodefendo5618pdgg
Standard Fastening Pattern
6 Nail I'Mern
Esquema con 6 claws
1' T
5 Sign Exposu
5 5/8" Exposure Nails re
Clavos
Erposidda de Mo ping Exposidda de 6618 potg.
6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
Sun nne:J rnswNng •na Moth
rr. 47YP�e1
t• tr it/I t2' Y
611E- SSIp'
�r
Pour 1- spoor orAspbO nwnn0 Cannot
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing — WeatherGuard® HP:
t
Slnjille Side Viers
IVbb lend
ern i
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certificate ofAuthorimtlon 0503 6TH EDITION (2017) FBC NON-HVH2 EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
r
QOTRINITYIERD
I
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard* HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgeTM Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Fig. t q
t— PlnpElfid
DMecUedEon A
A
Na9s-*
A 1 I
I r
•4 A i
q I I
I I i i
I 1
i i r r
e-
x►Exposure
r\
Fig. 2
TopMew
SldeVew
Nils
1-. Z' Top Lanboled r T
Z
weee
t- r '
i
i
0
I
JI
81
I
�I
1
1
1
h- it
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Fig. A q q
P=39MB U M
E— �ltcdbn A
A
A
♦ 'n i
q I 1
A I I
I I
Fig. C Hip & Ridge Shingle Fastening
TopVW
tLtlb nalb
r
zz^
I• etpocum
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-118
Cer*cate ojAuthothadon #9503 6TH EDITION (2017) FBC NON-HVH2 EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction sm ntstrip
6' Exposure
Fasten 7'h'
Cover Exposed
Fastonors with
< Roof Cement
I
��TRINITYI ERD
Standard -11._�
Fastening
Pattern
12° Sealant
Expos e
i
6.3.6 Minimum Nailing — DuraRidl;6' Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
on
U riaion Word
divot
Diraodon dal ritnto pm*mitanta
Nail n
I I I 1
I l
ROM
F
Top View
vu' m plan
I'I
II- VFttasuperlorNO
co
t
i ° • Orsm Getting SmcNa3' • Ct o
16
s I�?
�
olloE
V
0y
I0$
12' 1
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / 11905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly -evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASsuRANcE ENTITY:
LIL LLC— QVA9625 ; (631) 546-Z458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-118
Certtjtcate afAuthorkadon #9503 6n' EDITION (2017) FBC NON-HVH2 EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 20/09/2017
Page 8 of 8