HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVIT0
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Building Permit # Owners Name N Q_'Ey%c duo► 4vav� S— Applicant:
L
T Revised 07/22/2014
VY I have reviewed the above components or cladding and I have approved their use in this ucture. These products provide adequate resistance to the
wind loads and forces specified by current code provisions. fY1�Y 2018
Name: JAMES JOSEPH CANTWELL Signature: , seal
Design Prof. ARCHITECT Cert.No. AR001,2 Date: 05/08/18
Product
Opening Design
Product Rated
Manufacturer
Model Number
Product Approval
Glass
Method of Attachment
Pressures
Design Pressure
Number
Type
Windows
+32.37/-42.62
+50/-60 DP
Ply Gem
Series 4712 Flange
FL 14039.1
Non -Impact
# 10 Wood Screw with sufficient length to achieve l-1l4'embedment. Required anchors: Head(3), Jamb(3)
Mullions
N/A
+/-75 DP
Ply Gem
Series 4700 Flange
FL 15264.2
N/A
Use''/.' Tapcon with sufficient length to achieve a 1Y..- minimum embedment with 2 Ye minimum edge distance.
Fixed Glass
+29.65/38.87
+/-55 DP
Ply Gem
Series 4701 Flange
FL 14434.1
Non -Impact
910 Wood Screw with sufficient length to achieve l-114'embedment. Required anchors: Head(3). Jamb(3)
Block Glass
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Skylights
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Sliding Glass Doors
+28.74/-42.62
+/-50 DP
Ply Gem
Series 4780
FL 14634.2
Non -Impact
3/16'Tapmn with sufficient length to achlove 1.1/4-embedment. Required anchors: Head/Shc(6). Jamb(5) Each window.
Swing Type Doors
+30.64/-30.64
+67.0/-67.0
ThermaTru
3-o-.s-a-smooth Slar Fiberglass
FL5891.5
N/A
r1`w'/.
Tapcon',Min Embedment 1-1/4', Min Clearance toedge T, Mtn Clearsnmoa tdjarent ancrwr ;OR ELCO Tepmn 1/4', Min
French Doors
N/A
N/A
N/A
N/A
N/A
N/A I
N/A
Garage Doors
+25.91/-31.39
+36/-42
Clopay
16X7 Model73W6
FL16546.4
N/A
Jambloblockonvenimljembl/4'X11/4'minembeddedTapmn.Me,spacingof71Wand1'00steel—she, required.
Hurricane Protection
N/A
+40/-40
Eastern Metal Suplpy
24ga Steel Panels
FL 11964.2
N/A
1/4" Tapcon Anchors, SG Tapcons or 1/4" X 3/4". All points Solid -set Anchors.
Roof Ventilation
N/A
-, Roofing Material
N/A
N/A
Tamko
N/A
FL18355.1
N/A
snails per shingle. Standardtype roofing nail, nail shanks should he 12 gauge was and minimum heed of 318•.
C>