HomeMy WebLinkAboutVOID- ENERGY EFFICIENCY CODE/1yyf
IvoFORM R405-2017 ��( t
FLORIDA EI fbFk&,ODING CONSTRUCTIO
Fl ioi rids Department of Business and Professional Regu atlon - esidential Performance Method
Projecf,IName: Lot 001 F1452 B RHG - E
Builder Name: Ryan Homes
Street: 5214 Oakland Lake Cir
Permit Office: St. Lucie
City, St te, Zip: Ft. Pierce, FL,
Permit Number:
Owner:I
Jurisdiction: 661000
I
Design (Location: FL, Fort Pierce
)
County:: St. Lucie (Florida Climate Zone 2JI
1. New construction or existing New (From Plans)
9. Wall Types (1516.7 sqft.)
Insulation Area
III
2. Single,llfamily or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1265.30 ftz
b. Frame - Wood, Adjacent
R=11.0 251.33 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftz
10. Ceiling Types (1452.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
b. N/A
R=30.0 1452.00 ftz
R= ftz
6. Conditioned floor area above grade (ftz) 1452
Condi ! oned floor area below grade (ftz) 0
rl
c. N/A
11. Ducts
R= ft z
R ftz
7. Windgws(132.0 sli Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 290.4
a. U-Factor: Dbl, U=0.54 98.67 ftz
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.63 33.33 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.32
a. Central Unit
23.2 SEER:14.00
c. U-F� ctor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
23.2 HSPF:8.20
SI-IIGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.313
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor (Types (1452.0 sgft.) Insulation Area
EF: 0.900
a. Sla -On-Grade Edge Insulation R=0.0 1452.00 ftz
b. Conservation features
b. N/AR= ftz
None
c. N/q� R= ftz
15. Credits
Pstat
I!
Glass/floor
Total Proposed Modified Loads: 49.56
Area: 0.091
PASS
�7�7
Total Baseline Loads: 51.12
i
1 hereby)
certify that the plans and specifications covered by
Review of the plans and
STgpA
this cal "ulation
are in compli nce with the Florida Energy
specifications covered by this
O�'L
Code.
calculation indicates compliance
•�••'•�;,
��
RED BY:
with the Florida Energy Code.
rnn`';; : _ O
PREP
Before construction is completed
"(
DATE:'i
this building will be inspected for
compliance with Section 553.908
* "'
I hereb'�
certify that this building, as designed, is in compliance
Florida Statutes.
5�
COD
with th
Florida Ene y Code. - n
w
OWNER/AGENT
�
BUILDING OFFICIAL:
G
DATE
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certif,ed factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Com�iliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house.
6/13/21018 11:27 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
I
Pr)PKA R nr%-9ni 7
i
PROJECT
Title:
Building
Owner
# of U
BuilderjName:
Permit
Jurisdiction:
Family
New/Existing:
Comm
I
Type:
' ame:
jts:
Office:
ill ype:
Ilnt:
III'I
Lot 001 F1452 B RHG - E Bedrooms: 3
User Conditioned Area: 1452
Total Stories: 1
1 Worst Case: No
Ryan Homes Rotate Angle: 180
St. Lucie Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
001
Oakland Lake
5214 Oakland Lake Cir
St. Lucie
Ft. Pierce ,
FL,
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1452 12632.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
I
Main
1452 12632.4 Yes 4
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab
i
-On -Grade Edge Insulatio
Main 146 ft 0
1452 ft2
----
0.29 0 0.71
ROOF
V i
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Composition shingles 1573 ft2 0 ft2 Dark
0.5
N 0.5
No 0 22.6
ATTIC
V
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
I'
1
Full attic
Vented 300 1452
ft2
N N
I'
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1452
ft2 0.1
Wood
I
6/13/2018 11:27 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
c:nQne Qhnr_on!7
a
s
WALLS
Adjacent
Cavity Width Height Sheathing Framing Solar
Below
Omt
Space R-V;;I.lp Ft In Et
To Wall Type
In A ren B-Vahle
Ernnfinn Ah-,nr
Grade%]
1
N=>S
Exterior Concrete Block - Int Insul Main
4.1 47 6 8
8 411.7 ftz 0
0 0.6
0
2
� E=>W
Exterior Concrete Block - Int Insul Main
4.1 40 0 8
8 346.7 ft2 0
0 0.6
0
3
S=>N
Exterior Concrete Block - Int Insul Main
4.1 37 6 8
8 325.0 ftz 0
0 0.6
0
_
4
W=>E
Exterior Concrete Block - Int Insul Main
4.1 21 0 8
8 182.0 ftz 0
0 0.6
0
5 ii
-=>SE
Garage Frame - Wood Main
11 29 0 8
8 251.3 ftz 0
0.25 0.6
0
DOORS
#
Ornt Door Type Space
Storms
U-Value Width
Height
Area
Ft In
Ft In
it
1
W=>E Insulated Main
None
.39 3
6 8
20 ftz
2
I
-=>SE Wood Main
None
.39 2
8
16 ftz
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 180 degrees).
Wall
Overhang
v
# Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth Separation
Int Shade
Screening
1 N=>S 1 Metal Low-E Double Yes
i
0.54 0.31 N
16.4 ftz 1 ft 0 in 2 ft 0 in
Drapes/blinds
None
2 E=>W 2 Metal Low-E Double Yes
0.54 0.31 N
49.3 ftz 1 ft 0 in 2 ft 0 in
Drapes/blinds
None
3 E=>W 2 Metal Low-E Double Yes
0.63 0.32 N
33.3 ftz 1 ft 0 in 2 ft 0 in
None
None
I
4 S=>N 3 Metal Low-E Double Yes
0.54 0.31 N
16.4 ftz 1 ft 0 in 2 ft 0 in
Drapes/blinds
None
5 W=>E 4 Metal Law-E Double Yes
0.54 0.31 N
16.4 ftz 1 ft 0 in 2 ft 0 in
Drapes/blinds
None
l�
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
393 ftz 393 ftz
51 ft
8.7 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Whblehouse
Proposed ACH(50) .000387
1473.8 80.91 152.16 .2825
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
HSPF:8.2
23.2 kBtu/hr
1
sys#1
I
COOLING SYSTEM
j�
#
System Type Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
j
1
Central Unit/ Split
SEER: 14 23.2 kBtu/hr 696 cfm
0.75 1 1
sys#1
6/13/2018 11:27 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
Pr)PRA PAnr%-9nl7
HOT WATER SYSTEM
II # System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.9 50 gal 60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
77
FSEC
Collector
Storage
i
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/
----
---- Supply----
Return----
Air
CFM 25
CFM25
HVAC #
\/
# Location R-Value Area
i
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
f 1 Attic
6 290.4 ft
Main
72.6 ft2 Proposed Qn
Main
--- cfm
43.6 cfm 0.03
0.50
1 1
TEMPERATURES
Progra',mable
Thermostat: Y
Ceiling Fans:
Cooling)
Jan Feb
Jan Feb
Mar
Mar
Apr [
Appr l
May Jun Jul
May 4 Jun Jul
Aug
Aug[
rX� Sep
] Sepp
E
Oct
Oct
Nov
Nov
Dec
Dec
Venting
Ventin
Jan Feb
Mar
Apr l
May l 11 Jun Jul
Aug
[[[ ] Se
lxJ
Oct
Nov
Dec
Thermostat
Schedule: HERS 2006 Reference
Hours
Schedule
Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling '
IND) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling,;
EH) AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (W
D) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (W
EH) AM
66
66
66
66 66 68
68
68
68
68
68
68
1 PM
68
68
68
68 68 68
68
68
68
68
66
66
6/13/2018 11:27 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
Florida Building Code, Energy Conservation, 6th Edition (2017)
3tory Reauirements for Residential Performance, Prescriptive and ERI Methods
ADDR SS: 5214 Oakland Lake Cir Permit Number: I
Ft. Pierce, FL,
TORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
1.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
lay card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
:tion 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
)resold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
tiled in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
2.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
2.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
ie code official, an approved third party shall inspect all components and verify compliance.
.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
s per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
tnce with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
als as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) o
oved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
ce. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
18 11:27 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5
ATORY REQUIREMENTS - (Continued)
R40.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
oper} combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
en sed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Ifl Exceptions:
Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.41.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.11 Controls.
1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
13.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
13.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105OF (41 °C)
or below 55OF (1 WC) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
8 11:27 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5
TORY REQUIREMENTS - (Continued)
Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
award and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
storage tank.
Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100 °F to 140 °F (38 °C to 60 °C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
13.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
IIRange hoods
Any
2.8 cfm/watt
Any
4 In -line fan
Any
2/8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
III Bathroom, utility room
90
2.8 cfm/watt
Any
I�
or SI: 1 cfm = 28.3 L/min.
I
6/ 3/2018 11:27 AM
f
When tested in accordance with HVI Standard 916
EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5
4AI !1 ATORY REQUIREMENTS - (Continued)
R403. 1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
th.J� the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
eq 11 ipment shall not be less than the calculated latent load.
The pill lished value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expan ed performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temure for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
ies for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
13.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
A variable capacity system sized for optimum performance during base load periods is utilized.
8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
and C404 of the IECC—Commercial Provisions in lieu of Section R403.
3.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50OF (109C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40OF (4.8`C).
10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
18 11:27 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
Portable spas (Mandatorg0he energy consumption of electric -powered portable spas shall be controlled by the
ants of APSP-14.
SECTION R404
POWER AND LIGHTING SYSTEMS
R404Aj Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high-ej icacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
18 11:27 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5
FORM
405-2017
" ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*
= 97
The lower the EnergyPerformance Index, the more efficient the home.
5214 Oakland Lake Cir, Ft. Pierce, FL,
1. New'I
onstruction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Singh""
family or multiple family
Single family a. Concrete Block - Int Insul, Exterior R=4.1 •
1265.30 ft2
b. Frame - Wood, Adjacent
R=11.0
251.33 ft2
3. Number
of units, if multiple family
1 c. N/A
R=
ft2
4. Numb"I
r of Bedrooms
3 d. N/A
R=
ft2
11
10. Ceiling Types
Insulation
Area
5. Is thi
a worst case?
No a. Under Attic (Vented)
R=30.0
1452.00 ft2
6. Con d
Toned floor area (ftz)
1452 b. N/A
R=
ft2
7. Windows-
Description
Area c. N/A
R=
ft z
a. UIII
actor: Dbl, U=0.54
11. Ducts
98.67 ft2 a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 290.4
S
GC. SHGC=0.31
b. U
actor: Dbl, U=0.63
33.33 ft2
S'
,�
. SHGC=0.32
12. Cooling systems
kBtu/hr
Efficiency
c. U-factor:
iI
N/A
ft2 a. Central Unit
23.2 SEER:14.00
S,
C:
d. U,
actor: N/A
I
ft2
13. Heating systems
kBtu/hr
Efficiency
S
p
Area
GC:
Weighted Average Overhang Depth:
1.000 ft. a. Electric Heat Pump
23.2
HSPF:8.20
Area,
Average SHGC:
0.313
IVeighted
8. Floor
lrypes Insulation Area 14. Hot water systems
Cap:
50 gallons
a. Slab
-On -Grade Edge Insulation R=0.0 1452.00 ft2 a. Electric
EF: 0.9
b. N/A
R=
ft2
c. N//}�
R=
b. Conservation features
ft2
None
15. Credits
Pstat
I certify t�tat this home has"complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this ho�a before final inspection. Otherwise, a new EPL Display Card will be completed
based o � installed Code compliant features.
Builder Signature: Date: 6 ZgjS. Address' f New Home: 5214 �J'cjLao Ct,( _ City/FL Zip: T:4 'qEylto
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
tech support@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
cer4fied Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Cormmission's support staff.
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8 11:27 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
2017j - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
i
Pr
ject Name: Lot 001 F1452 B RHG - E Builder Name: Ryan Homes
Sfr
et: 5214 Oakland Lake Cir Permit Office: St. Lucie
Ci
I`If, State, Zip: Ft. Pierce , FL, Permit Number:
OV
ner: Jurisdiction: 661000
D
II ign Location: FL, Fort Pierce
CO
PONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
Gene
"al
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
11
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requir
ments
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiliri
/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
I
Knee walls shall be sealed.
minimum.
I
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Wind
ws, skylights
The space between window/door jambs and framing, and
and d;
ors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floor,
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(inclu
` mg
insulation.
maintain permanent contact with the underside of
abovE
garage
subfloor decking, or floor framing cavity insulation
and c
I
intilevered
shall be permitted to be in contact with the top side
floors,
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Craw
j�
space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shaffll
Duct shafts, utility penetrations, and flue shafts opening to
,penetrations
II
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrol
cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Gara'
`e separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed
lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
fshall
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plum
ing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind p6pong and wiring,
ShoAr/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on a+rior
wall
tubs shall separate them from the showers and tubs.
be insulated.
Elect
°cal/phone box o
The air barrier shall be installed behind electrical or communication
exteri
` r walls
boxes or air -sealed boxes shall be installed.
HVA
J register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Conoialed
When required to be sealed, concealed fire sprinklers shall only be
spridl`ers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fore so V nkler nover dates and walls or yeplinns,
a. In aip dition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/13/2 , 16 11:27 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I
i
h
Job: Lot 001 F1452 B RHG
11 rightsoft® Project Summary Date: 04/12/2018
Entire House By: RI/LF
One Stop Cooling and Heating
7225 Sa stove Coot, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.com Licerse: CAC032444
For: Ryan Homes
Notes:
Weather: Fort Pierce, FL, US
Winter Design Conditions
t db 42 °F
lb 68 `F
TD 26 OF
Heating Summary
Structure
15406
Btuh
Ducts
1426
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
16832
Btuh
Infiltration
Method
Simplified
Construction quality
Average
FireDlaces
0
Heating
Cooling
Area fn
1453
Volume (ft3)
12639
12639
Air changes/hour
0.45
0.23
Equiv. AVF (cfm)
95
48
Heating Equipment Summary
Make Goodman Mfg.
Trade GOODMAN; JANITROL; AMANA DISTI...
Model GSZ140241 K
AHRI ref 7995055
Efficiency
8.2 HSPF
Heating input
Heating output
23200 Btuh @ 47OF
Temperature rise
0 OF
Actual airflow
0 ctrn
Air flow factor
0 cfm/Btuh
Static pressure
0.50 in H2O
Space thermostat
apacity balance point = 35 cF
Backup:
Input = 9 kW, Output = 29982 Btuh,100 AFUE
Summer Design Conditions
Outside db
90
cF
Inside db
72
`F
Design TD
18
cF
Daily range
M
Relative humidity
50
%
Moisture difference
68
grAb
Sensible Cooling Equipment Load Sizing
Structure
14816
Btuh
Ducts
2813
Bluh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data n
Rate/swin multipplier 0.95
Equipmenisensibleload 16747 Btuh
Latent Cooling Equipment Load Sizing
Structure
3035 Btuh
Ducts
699 Btuh
Central vent (0 cfm)
0 Btuh
(none)
Equipment latent load
3734 Btuh
Equipment Total Load (Sen+Lat)
20481 Btuh
Req. total capacity at 0.75 SHR
1.9 ton
Cooling Equipment Summary
Make Goodman Mfgg.
Trade GOODMAN; JANITROL; AMANA DISTI...
Cond GSZ140241 K
Coil ARUF25614A
AHRI ref 7995055
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
11.5 EER,14 SEER
17400
Btuh
5800
Btuh
2377Btuh
3
cffrn
0.044
cfm/Btuh
0.50
in H2O
0.83
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wr10ht:Soft- 2018-Jur1311:18:13
• *• w, ^� Riga-Sute®Uriversal201818.0.11 RSU23249 Page 1
imatortDesldopUEMPlot 001 F1452 B RHG - E.rrp Calc = WS Horse faces: E
rightsoft° Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sgdsmve Court, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopGoolirg.com License: CAG032444
Jab: Lot 001 F1452 B RHG
Date: 04/12/2018
By: RI/LF
1
2
3
4
5
oom name
1 wall
goom height
Room dimensions
'doom area
Entire House
146.0 It
8.7 ft d
1452.8 fF
DIN
205 ft
8.7 ft heaV000l
11.0 x 95 It
104.5 fF
`
ly
Construction
number
U-value
(Btuh/ftz'F)
Or
HTM
(Blu
Area (if2)
or perimeter (ft)
Load
(Btuh)
Area (W)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/5
Heat
Cool
Gross
N/PS
Heat
Cool
6
11
I�
C
F
1
�—
.
13A flocs �- -^,
4A5aom'.-4�_.__._.0540
13A-4ocs
4A5-2om
11 DO
13A flocs -
4P5-2om_.__ _
13A4acs
4A5-2om
4A5 2omd
_
168-30ad
0.143
0.143
0.540
0.390
"A
_ __0540
0.143
0.540
0.091
-�0:091
0390
0.032
n
.n_:._
a
a
a
_..
s
_s_�
w
w
w
-
_rt
.
372
._ i404
3.72
14.04
1014
3J2
_y _1404
3.72
14.04
1638
237
__ 1014
0.83
--
2626
1436,'._
2.62
34.14
1150
2.62
1436
426
34.14
42.09
133
_.:11.50
1.70
0.00
_-_--_16
183
16
20
413
_ i6
16
49
34
_
252
__16
_1453
_
310
_ _:- .0'--_-
146
0
20
397
_ - i6
265
0
236
--- --- 16
1453
1152
_ -- 229
544
229
204
14-M
_ . w .229
229
688
549
�9'
. 1209
479»_04_
- — 811
- -- 235
383
558
231
10 S
' .: Zi5
695
1674
1410
314
2464
"' 0
__: .. �0
0
0
0
83
_0
.-_ 0
0
34
- " U
105
105
0
_:__._�0
0
0
83
_T __._0
62
0
0
0
105
_ '__ 27
0
0
0
0
0
;
— - 0
D
_'__0 .
0
0
0
--2i6
�._._0
231
0
549
87
163
0
1410
177
.� —629
=__ 0
I
6
AED emu sion
10061
491
Envelope loss/gain
12697
11237
1803
2457
12
) Infiltration
Room %enlilation
2709
0
958
0
380
0
135
0
13
'
�PI
mal gains: Ooc/pards @ 230
Applianoes/other
4
920
1700
0
0
0
Oubtotal
(lines 6to 13)
1 15406
14816
2183
2592
14
15
h11 ssexlemalload
transfer
edisbibution
§ubtotal
uct loads
91/.
190/0
0
0
0
15406
1426
0
0
0
14816
2813
9'/
190/0
0
0
0
2183
202
0
0
0
2592
492
i
otal room load
r required (cfm)
16832
0
17629
773
2386
01
3084
135
Calculations approved byACCAto meet all
F�r- wrigFrttsoR� 201 8-ArA 3 11:18:13
Right-Suite®Uriversal 201818.0.11 RSU23249 Page 1
imator\Desldop\TEMP\Lot 001 F1452 B RHG - Exup Calc = MJ8 House faces: E
+�irightsoft Right-J® Worksheet
Entire House
One Stop Cooling and Heating
I
7225 Sapdscove Court, Winder Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopGooling.com Licerse: CA0032444
Job: Lot 001 F1452 B RHG
Date: 04/12/2018
By: RI/LF
1
2
3
4
5
,
Doom
Doom
Room
oom name
wall
height
dimensions
area
GREAT
14.0 ft
8.7 ft heaV000l
1.0 x 298.0 ft
293.0 1
MBED
30.0 ft
8.7 it heatlmol
1.0 x 227.0 ft
227.0 ftz
0
Construction
number
U-value
(Btuh/t2�q
Or
HTM
(Btu
Area (T)
or perimeter (ft)
Load
(BWh)
Area (T)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
11
II
- Ir
R I
F
-. f
l
13A-4o�s
_4A52om_
13A-4oas
4A5-2om
11 D0
13A4ors
4AS-2om .
13A 4ocs
4A5-2om
4A5-2omd
1 0__
122Apm _ ..
--- -
0:143
.0.540
0.143
0.540
0390
0143
0540
0.143
0540
0.630
. _ 0�90 3
- _80
1:0,
ri
--n-
a
a
a
s
s_
w
w
w
_n....
= y
-
3J2
-- .14.04
3.72
14.04
10.14
372
_ 1404.
3.72
14.04
1638
_ 10.14.
- --
3068
262
-1.436
2.62
34.14
11.50
2.62rf
_ 1436
2.62
34.14
42.09
-_ 1150
- -0-
._ 00
_ -' 131
16
-' -14'
-.0
0
0
- 0
0
.-_-0
114
0
0
---_ •- _ �
__-._0
227
` 424'
---229,
0
0
_ 0
- -0
.-----0
- ---
;m
_�235.
0
0
0
0
299
558
0
385
---.__0
-- -`,0
' 0
0
0
0
0
U
0
0
0
� 0
0'�
._ 0
122
33
_ 0
,�-0
_ -�
_�_298
0
0
0
0
0
0
0
0
- 0
- - 0
__ 0
233
1116
0
-----0
0
0
0
0
0
--0
131
16
0
- -- Q
--0
227
227
0
0
s 0'
0
89
0
0
- 0
331
459
0
--- Q
0
424
229
_ ... 0
.---0
----189
- ---
298
248
_
505
i4'
430.-
0`-
-
90._L_920-
-'
6
} AED exausion
485
137
I
"lope loss(gain
1468
2340
24171
1912
12
Infiltration
I Room venfitation
260
0
92
0
557
0
197
0
13
,11111 re OaupantsCd) 230
Appliances/other
0
0
0
2
460
0
u ubtotal (lines 6 to 13)
1727
2432
2974
2569
14
15
IlLessextemalload
lL sstransfer
opdistribution
Subtotal
Putt loads
90/6
19%
0
0
200
1927
178
0
0
323
2755
523
91/6
190/0
0
0
0
2974
275
0
0
0
2569
488
lllotal room load
Air required (cfm)
2105
01
3278
144.
3249
0
3057
134
=Motut soft-
" ' Right-SniteOUriversal201818.0.11 RSU23249
imator\Desldop\TEMP\Lot 001 F1452 B RHG - E.np Calc = W8 House faces: E
2018-ArO 311:18:13
Page 2
rightsoft- Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sa%dscove Court, Winder Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.wm Lioerse: CAC032444
Job: Lot 001 F1452 B RHG
Date: 04/12/2018
By: RI/LF
1
2
3
4
5
, oom name
sed wall
¢doom height
doom dimensions
f� oom area
Krr
9.0 ft
8.7 ft heat/eool
1.0 x 126.1 ft
126.1 1P
PAN
4.0 ft
8.7 ft heaVmol
1.0 x 16.9 ft
16.9 ftz
y
Construction
number
U-value
(Btuwq
Or
HTM
(BtuW
Area (fP)
or perimeter (ft)
Load
(Bluh)
Area (ftz)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
-
_ I�
_II
F}
�_ -_
_
13A4ocs -
-_4A.5-2dm:_.�r.�
13A-4ocs
4A5-2om
11 DO
4Ar2om. ,
13A-4ocs
4A5-2om
4A5-2omd
_
0:143'
-'TOS40
0.143
0.540
0390
_0540
0.143
0.540
0.630
n-
-n-
a
a
a
-ss
w
w
w
-
_-_ ._
3.72
'a_ 14.04
3.72
14.04
10.14
- 14114
3.72
14.04
1638
.____.�__
262
'_,_.143-6.
2.62
34.14
11.50
1436
2.62
34.14
42.09
__ ._._ __
0.
_ -' _0
0
0
0
0
- T--0
0
0
-
0
.�_.__-_0
0
0
0
__ _ _ _0
0
0
0
__ . - -_
0..
._- -_ -0
0
0
0
_._
0
0
0
_ -- _
0
__ _ '__ 0
0
0
0
_
0
0
0
-
0
_ . A
0
0
0
_ - ' 0
0
0
0
0
0
0
0
" 35
0
0
0
0'
_.
0
0
0
0
129
0
0
0
- 0
- -
0
0
0
0
91.
0
0
0
.- _O
C
F`
-=-
16&30ad _ -
m-= - , =
0390
0.032
F 1;i80
_n__
��
10.14.-_1150-__0
_.. 0,83
__30.68
1_70
,_ :_0.00
126
__ 126._v.
.---_._0
126
_._ 9
_ Y 105
�_ ._276
0-
214
, _,0
_-.- ---0.
17
__. - 17
_ _ 0
17
�_ 4
14
-.___---123
y 29
- --
-
-
-
-
- -
-
-
--
6
AED excursion
-65
6
Iopelossrgain
672
354
266
114
12
) Infiltration
167
59
74
26
Room ventilation
0
0
0
0
13
rdemalgains: Occupants@ 230
0
0
0
0
Appliancesrother
1200
0
ubtotal (lines 6to 13)
1839
1613
1340
140
f�
ssexternalload
0
0
0
0
I,esstransler
0
0
0
0
0edistribution
3
6
0
0
14ubtolal
842
1619
340
140
15
Udloads
91/6
19%
78
307
91/6
190/0
321
27
Ifl
Total room load
�r required (dm)
1
920
0
1926
84
372
0
167
7
wrightsoitm
Right-SuiteOUriversa1201818.0.11 RSU23249
imator\Desktop\TEMP\Lot001 F1452 B RHG - Exup Calc= W8 House faoes: E
201 B-Jurr1311:18:13
Page 3
Vi rightsoft- Right-J® Worksheet
Entire House
One Stop Cooling and Heating
i
7225 Sarldscove Coin, Wihter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoolirg.com License: CAC032444
Jab: Lot 001 F1452 B RHG
Date: 04/12/2018
By: RI/LF
1
2
3
4
5
Doom
Doom
doom
oom name
well
height
dimemdons
area
NNVIC
0 ft
8.7 ft heaYbool
8.0 x 7.0 ft
56.0 #2
NBTH
12.0 ft
8.7 ft heat/cool
1.0 x 107.5 ft
107.5 fF
y
Construction
number
U-value
(BtuWc9
or
HTM
(Btuh/f6)
Area (ill)
or perimeter (ft)
Load
(Bluh)
Area OF)
or perimeter (ft)
Load
(Btuh)
Heat
I Cool
Gross
NIPS
Heat
Cool
Gross
N/PS
Heat
Cool
6
11
�
-,III
III
h
�.I�.
II
C
m flocs
4A5-26m,, -
13A-4ocs
4A5-2om
11 D0
134-0ocs
AA5-2om _
13A-4ocs
4A5-20m
4A5-2omd
72COSw
11D0-._
168.30ad
.
-
0143
0540
0.143
0540
0290
:0143
0.540.
0.143
0540
0.630
0.091
.0390
0.032
-- - -
'n
. n'
a
a
a
s,
- s
w
w
w
_ ri_.
-
372
I'_ 14A4.'--
3.72
14.04
10.14
3.72
14.04
3.72
14.04
1638
237
10.14
0.83
-
2&2
_1436
2.62
34.14
1150
262'
1436
2.62
34.14
42D9
1.33
_ 1150
1.70
0
_ -� _ 0
0
0
0
- 0
- - -_ -0
0
0
0
--70
_ _ r0
56
56
- -
_ 0
0
0
0
O
---0
0
0
0
' , 76
--_0'-
56
.0
, ` 0
". _ _104
_ 104
—0
-! r 988
0
0
0
0
0
0
0
� .154
—._0
89
X_368,
273
0
0
0
- 0
0
0
__ 0
87
0
182
0
0
0
Y_ 0
0
0
0
0
_�- . 0
0
0
0
0
0
0
_ U
0
0
0
0
0
0
m� U
. _ ---0
0
0
0
__.= _- 65
_ ' 0
108
-
0
0
0
-- 166
0
- -7 .792
0
A 65
0
47
95
108
__ -0
—
-0
µ 108
12
—_
--
-
-
---
_M-
-
' -
--
6
��
AED .,do,,-
7
-24
Mope loss(gain
211
180
1000
518
12
Infiltration
Room ventilation
0
0
0
0
223
0
79
0
13
Ili
itfrtemalgains:
Ooaipartls@ 230
Applianoes/other
0
0
0
0
0
0
ubtotal (lines 6 to 13)
211
180
1223
597
14
15
subtotal
Puct
"e)temalload
'transfer
edistribution
loads
9%1
19%
0
0
62
273
25
0
0
373
553
105
9%
19%
0
0
0
1223
113
0
0
0
597
113
i
/
otal room load
�ir required (cfm)
298
0
658
29
1336
0
710
31
ons approved byACCAto meet all requirements of Manual J 8th Ed.
w 10ftt:6.C.Ve ^ 2018-Ju-1311:18:13
"'""' Right-Suite®Uriversal201818.0.11 RSU23249 Page
imator\Desldop\TEMP\Lot 001 F1452 8 RHG - E.np Calc = W8 House faces: E
fl- rightsoft" Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sat6ocve Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.com Ucerse: CAC032444
11
Job: Lot 001 F1452 B RHG
Date: 04/12/2018
By: RI/LF
1
2
3
4
5
doom name
F�osed wall
boom height
oom dimensions
gloom area
O ft
8.7 It heat/000l
5.5 x 4.0 ft
22.0 fF
BTH2
O ft
8.7 ft heat/000l
5.5 x 85 It
46B iF
JJu
Ty
Construction
number
U-value
(BtuW'F)
Or
HTM
(BluW
Area (ftz)
or perimeter (ft)
Load
(Btuh)
Area (fF)
or perimeter (ft)
Load
(Btiih)
Heat
I Cool
Gross
N/P)S
Heat
Cool
Gross
N1R5
Heat
Cool
6
11
` ��
WVlil
III
�t
Ik
C]i�-
1
G
II
13A 4as
4A5.2om
13A-4as
4A5-2om
11 DO _ -
13A-4as"
_4A5 2om..—_
13A-4ars
4A5 tom
4A5-2omd
12C-Osw _
_11DO--___
1613-30ad ---- -
-a! 0.143
_0540
0.143
0.540
0390
�_.0.14
-3
---0540
0.143
0,540
0.630
0.091
—_ 0390
0.032
----
1_180
- rid
.-n_
a
a
a
s -
' s_
w
w
w
-rt_
—
.—
— 3.72
14.04.
3.72
14.04
10.14
-3.-72
14.04,
3.72
14.04
16.38
- ' 237
_--10.14
0.83
- — ---
30.68
262
—1436
2.62
34.14
11.50
. -
2.62
_ _ 1.436
2.62
34.14
42A9
- 1.33
,_- 1150
1.70
-- - -
._ _0.00
' _ _. 0
. -0
--- 0
--__ 0
0
0
-- --_- 0
0
0
,- -
—0
0
0
0
-- -
D
.- -- ._ U
0
0
0
_ _ _ _ . _ 0
- 0
__ - _- _ 0
0
0
0
0
- - 0
0
0
0
0-
37
- - -
-- - U
0
.-- _ _0
0
0
0
-
0
0
0
0
0
0
- 0
47
- -
------ 47
- -
0
_-- _ _ _ _0
0
0
0
. 0
'.. 0
0
0
0
0
___. -0
47
-- --- 0
- - -
. _ -0
- _ - 0
0
0
0
0
_
- _ 0
0
0
0
0
_-_ _- 0
39
- - --
_ 0
. -0
0
0
0
0
0
0
0
0
0
_-0
79
- -
--- - -
0
0
0
.` _ 0
- v - 0
0
0
0
_ _. _ O
-_ '-0
.- 22
��:=�
0
0
0
_-�
0-0---0
22
--
0
18
- -
---0
- —
---_.__
----
6
C�
AED .,-do,,-
-1
-3
ui
"lopeloss/gain
18
36
39
76
12
a) Infiltration
fi) Room ventilation
0
0
0
0
0
0
0
0
13
emal gains: Ooauwls @ 230
Appliancesiother
0
0
0
0
0
0
LII
Subtotal(lines 6to13)
18
36
39
76
14
151
Lesswdemal bad
Lesstransfer
Redistribution
Subtotal
Rudloads
9%
19%
0
0
-18
0
0
0
0
-36
0
0
90/0
190/0
0
0
511
550
51
0
0
398
474
90
11
Total room load
�r required ((fin)
0
0
0
0
601
0
564
25
J 8th Ed.
-F"- wrightsoftm 2018-Jurt•1311:18:13
Rigft-SuiteDUriversa1201818.0.11 RSU23249 Page
imatorTesldop\TEMPIot 001 F1452 B RHG - E.rup Calc = W8 House faces: E
v'irightsoft' Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sajidscove Court, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopGoolirg.com License: CAC032444
Job: Lot 001 F1452 B RHG
DatB: 04/12/2018
By: RULF
1
2
3
4
5
boom
6Wsed
doom
name
wall
oom height
tom dimensions
area
LDRY
0 ft
8.7 ft heat/cool
3.5 x 7.0 ft
24.5 f8
BED3
14.0 ft
8.7 ft heaUmol
11.0 x 14.0 ft
154.0 fF
u
y
�
Construction
number
U-value
(Btuh*T-)
Or
HTM
(BtuhH<z)
Area (ftz)
or perimeter (ft)
Load
(Btuh)
Area (fR)
or perimeter (ft)
Load
(Bluh)
Heat
Cool
Cross
N/P5
Heal
Cool
Goss
N/P/5
Heat
Cool
6
11
-�
V)!i
III
11-G4A5-2omd
F�
_'-0390
CI
-M
I
--(�
4A5 2om_... -- -_
13AAos
4A5-2om
11 DO
13A 4ots -
_4Ar2om:.__ ....:
13A-4os
4A5-2om
166-30ad
_ ---
- _ 0540
0.143
0540
0.390
0.143
0540:'
0.143
0.540
0.630
0_032
1.180
- -
ri
- n
a
a
a
s
s..
w
w
w
__n _
-. _
3.72
14D4,
3.72
14.04
10.14
-332
14.04
3.72
14.04
16.38
-237
_ 10:14
0.83
: 30.68
--
-
2.62
1436
2.62
34.14
1150
' _ 252
.. 1436
2.62
34.14
42.09
1-M
_1150
1.70
_. _ .. 0.00
. _ - 0
- .:__ 0
0
0
0
.0
. _ . --,0
0
0
0
.30
.... _-0
25
, - _ _29
- -- --
� - 0
. __ _ �0
0
0
0_
- 0R_
.-_ _. _0
0
0
0
NO
-- _-0
25
.- T 0
;-_0
0
0
0
__ - U
0
0
0
- - 72
------ __O
20
--.---0
.- 0
0
0
0_
�,.-- 0
0
0
0
---0
0
--0
0
d-0
0
0
0
- 229
0
0
0
- _- ,0
0.
0,
0
0
0
--_ 235
0
0
0
- p
--___0
0
0
0
f- 16
0
0
0
_ 0
0
0
0
0
r • i6
0
0
0
-. - O
0
l-pG
T'
_
, - 40
_._..-0
42
- 0
_j 154
_ �- 154
f 154
1_4�
_128
261
-_
.. _- 0
_ _
U
-
--
----
it-----
-�-- -
_---
--
--
- -
------_--
6
c)
AED.,.!on
-23
-12
�o
�rwlope loss(gain
92
59
1179
760
12
a)
0,)
Infiltration
Room ventilation
0
0
0
0
260
0
92
0
13
'l
Ir
mad gains: Occupants @ 230
Appliano=srother
0
0
500
1
230
0
Oubtotal
(lines 6to13)
92
559
1439
1082
14
15
Lessextemalload
Ilesstransfer
Redistribution
Subtotal
puctloads
91/6
19%
0
0
-92
0
0
0
0
559
0
0
9%1
19%1
0
0
146
1585
147
0
0
114
1195
227
m
IT room load
tUr required (dm)
0
0
0
0
1732
01
1422
62
CalCul
ArF- wriglFftsoTrt'°
Rigtt-Suite® Universal 2018 18.0.11 RSU23249
imator\Desldop\TEMP\Lot 001 F1452 B RHG - E.nQ Calc = W8 House faces: E
2018-Jun-1311:18:13
Page 6
I
- if" rightsofV Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 S�%dsmve Court, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirij.com License: CAC032444
Jab: Lot 001 F1452 B RHG
Date: 04/12/2018
By: RI/LF
1
2
3
4
5
1,00m name
bposed wall
Poom height
oom dimensions
'doom area
BED2
37.0 ft
8.7 It heaU000l
15.5 x 11.0 ft
170.5 fF
FOY
55 it
8.7 ft heat/cool
1.0 x 99.0 It
99.0 fF
ci
T
Construction
number
U-value
(BtuW-9
Or
HTM
(Btuhlft�
Area II
or perimeter (ft)
Load
(Btuh)
Area (its
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
N/PS
Heat
Cool
6
11
V�J
I'
�� II
�-
CII
I
I
13A-4ds -
_4A5 tom- - - -_ -
13A flocs
4A5-2om
11DO
-
13A-0ors
4il5r2om. -------- _
13A-4ocs -
4A5-2om
4A5-2omd
12C-0sw-
_11D0
16B-30ad _-- ~
-- _ ----
- - 0. 443
_ _ __0540
0.143
0.540
0.390
0:143
__ _-0540
0.143
0540
0.630
0.091.
_ 0390
- 0.032
-----
� n
__n_
a
a
a
_`'i
s _
w
w
w
_n_
372
_ -1404
3.72
14.04
1014
- 372
14.04•'-_
3.72
14.04
16.38
2.37
__ 10.14'�ii50
0.83
- --
. 2.62
t426
91
91
0
_-- -146
340
--0
441
229
- 0
356
,- _--0
0
0
0
_ ----
239
^.--0
310
558
0
. 250
0.
0
0
0
0
'---.0
289
- -
- -- 0
-
0
- - _-0
48
0
20
0
__- __ _0
0
0
0
87
_-_.__76
99
- 99
- -
0
- _0
28
0
20
0
_. _ 0
0
0
71
_ 16
_ _ 99
-
- _ .-----6
---
0
0,
103
0
204
0
- 0.
0
0
___ .. _162
82
---_-169.
-
0
_ 0
73
0
231
0
0
0
0
. 184
168
_ 0
IIG
D
-
2.62
34.14
- 11.50
262
1426
2.62
34.14
42.09
133
1.70
--
_--.-0
135
16
-_ 0
96
- -0---0
0
0
0
0
_ . �0,--_0."
171
-
_
119
0
0
`- 96
0
0
0
0
171
-._ --
-
37
0
0
- 142
`- 1135
6
c) AED excursion
65
-31
, -Iope loss/gain
26Q
1711
888
720
12
S) Infiltration
b) Room ventilation
686
0
243
0
102
0
36
0
13
�I
malgain. Occupartlsca� 230
I Applianoesbther
1
230
0
0
0
0
�ubtotal(lines 6to13)
3329
2184
990
756
14
15
llessextemalload
Less transfer
Redistribution
Subtotal
Duct l0
1 9%1
199/6
0
0
180
3509
325
0
0
137
2322
441
9%
19%
0
0
-990
0
0
0
0
-756
0
0
ui
Total
flir
room load
required (10
3834
2762
121
0
0
0
0
Calculations approved byACCA to meet all requirements of
-F�&- 2018-Jur1311:18:13
Right-Sute®Universal 201818.0.11 RSU23249 Page
imatorlDesIdop\TEMPLot 001 F1452 B RHG - E.np Calc = W8 Horse faces: E
-�- wrightsofte static Pressure and Friction Rate
Entire House
One Stop Cooling and Heating
7225 Saidsoove Coat, Wirier Park, FL 32792 Ptnre: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStDpCoolirg.com Licerse: CAC032444
For: Ryan Homes
Jab: Lot 001 F1452 B RHG
Date: 04/12/2018
By: RI/LF
Heating
Cooling
(in H2O)
(in H2O)
ial static pressure
0.50
0.50
sure losses
Coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
able static pressure
0.34
0.34
Total
supply
Return
(ft)
(ft)
lured length of run -out
12
0
lured length of trunk
12
0
,alent length of fittings
110
0
length
134
0
effective length
134
FrictionRate
Heating
Cooling
(in/1001t)
(in/100ft)
ly Ducts
0.253 > 0.18
0.253 > 0.18
n Ducts
0.253 > 0.18
0.253 > 0.18
4X=35,11 A=20,11 G=5,11 G=5,11 G=5,1 A=35,11 Gam: Total EL=110
Total ELF
-' - wrightsoft® 2018-An.1 3 11:18:14
oM..=.• �. �,.•w,„..,mmw., Riga-Sute®Uriversal201818.0.11 RSU23249 Page 1
imator\Desktcp\TEMP\Lot 001 F1452 B RHG - E.np Calc = W8 Horse faces: E
+� �inrrightsoft® Duct System Summary
�I Entire House
One Stop Cooling and Heating
7225 S�Mscove Cout, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoolirg.com Licerse: CAC032444
For:
Exte ' al static pressure
Press°relosses
Available static pressure
Supple / return available pressure
Lowe%fric'on rate
Actulair flow
Tota.. .ve length (TEL)
Ryan Homes
Heating
0.50 in H2O
0.16 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.253 in/100ft
0 cfm
134 ft
Job: Lot 001 F1452 B RHG
Date: 04/12/2018
By. RI/LF
Cooling
0.50 in H2O
0.16 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.253 in/100ft
773 cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mal
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BED
P,
c 2762
0
121
0.269
8.0
Ox 0
VIFx
21.5
105.0
S2
BED31
c 1422
0
62
0.310
6.0
Ox0
VIFx
14.7
95.0
st2
BTM?
c 564
0
25
0.298
4.0
Ox 0
MR
14.1
100.0
st2
DIN
c 3084
0
135
0.274
7.0
Ox 0
MR
29.1
95.0
sti
GRE1.
c 1639
0
72
0.299
6.0
Ox0
MR
18.7
95.0
sti
GREFI-A
IT
c 1639
0
72
0.306
6.0
Ox0
MR
16.3
95.0
st1
KR
c 1926
0
84
0.271
6.0
Ox0
MR
25.5
100.0
sti
nBE
r
c 3057
0
134
0.276
7.0
Ox0
VIFx
23.3
100.0
sti
c 710
0
31
0.271
5.0
Ox 0
VI Fx
25.7
100.0
sti
Imuvll
c 658
0
29
0.253
4.0
Ox0
MR
24.3
110.0
sti
PAN
�,
i
c 167
0
7
0.272
4.0
Ox 0
VI Fx
25.0
100.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Na
(cm)
(cm)
(im)n
(in)
(in)
Material
Trunk
sti
PeakAVF
0
557
0.253
710
12.0
0 x 0
VnIFIX
st2
PeakAVF
0
216
0.269
488
9.0
0 x 0
VinlFlx
Grille
Htg
Clg
TEL
Design
Woc
Diam
H x W
Stud/Joist
Duct
Name,
Size (in)
(Ctm)
(Cim)
(ft)
FR
(ipm)
(in)
(in)
Opening (in)
Mal
Trunk
rbi
0x0
0
773
0
0
0
0
Ox 0
MR
Job #: Lot 001 F1452 B RHG - E
Performed by RI/LF for:
Ryan Homes
Level 1
One Stop Cooling and Heating
7225 Sandscove Court
Winter Park, FL 32792
Phone: (407) 629 - 6920 Fax (407) 629 - 9307
www.OneStopCooriirg.com
Scale:1 : 79
Page 1
FAghtSuite® Universal2018
18.0.11 RSU23249
2018-Apr-13 10:16:27