Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department SCANNED Building & Code Regulations Division BY 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-155,�0 Lucie County Certification for Design Load Compliance Project Name: Project Address: G 7 0-7 1�%'! 7- All f- 0& - Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and . certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft 5. Mean Roof Height ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Desiggn� Pressures Used: (PSF, based on 10sgft @ �/5'MRH, clearly label on all plan openings tZD, L ¢ zp.2. d-20, 2- +3S'. vF�5'- ? Zone 1: c 3 Z Zone 2: -!Ml Zone 3: 4'Z 7-Zone 4: -3 , Zone 5:-`� � Garage: t3�i 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NSA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: �Q1,7 (� ��•'+Y Y 6 � � ��� 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces spec' 'ed: po0, 7- P A)OffLc e TO Print Name Cert # & Co. Cert Auth. v A) Si � u,e,Date=a ' Se �. /�� 3� S� �>Ji�� SdIC• Company Name & Address 64:ftr Revised 07/25/ 014