Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODECS.CLAN�� ED OPy�FILE FOR R405-2017 St. BY Cunt FL i RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION F orida Department of Business and Professional Regulation - Residential Performance Method Proje Name: MW-56 Builder Name: Street. 2664 CONIFER DR Permit Office: City, tate, Zip: FORT PIERCE, FL, 34951 Permit Number: Owne : Jurisdiction: Desig I Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. Newii onstruction or existing New (From Plans) 9. Wall Types (1830.1 sgft.) Insulation Area 2. Sing l family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft2 b. Frame - Wood, Adjacent R=11.0 197.56 ft2 3. Nu er of units, if multiple family 1 c. N/A R= ft2 i 4. Nu er of Bedrooms 2 d. N/A R= ft2 10.lCeiling Types (1832.0 sgft.) Insulation Area 5. Is thi a worst case? No a. Under Attic (Vented) R=30.0 1832.00 ft2 6. Con itioned floor area above grade (ft2) 1832 b. N/A R= ft2 Co itioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Win ows(263.7 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 592 a. Factor: Dbl, U=0.62 263.67 ft2 GC: SHGC=0.26 b. -Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency HGC: a. Central Unit 36.0 SEER:16.00 c. -Factor: N/A ft2 HGC: 13. Heating systems kBtu/hr Efficiency d. -Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 HGC: pp Are' Weighted Average Overhang Depth: 0.000 ft. Are Weighted Average SHGC: 0.260 14. Hot water systems 8. Flo' r Types (1832.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. ab-On-Grade Edge Insulation R=0.0 1832.00 ft2 b. /A b. Conservation features EF: 0.940 , R= ft2 None C. A R= ft2 15. Credits Pstat Glas Total Proposed Modified Loads: 58.01 /Floor Area: 0.144 PASS Total Baseline Loads: 61.26 I I her by certify that the plans and s ecific tions cov red by Review of the plans and ST.q�t� this Iculation are in compliance wit the Flor a E rgy specifications covered by this 01.0iB Cod 7�- calculation indicates compliance the Florida Energy Code. i4 ,�� ,, - ... . i";:°;;•� with n,,,, „ .O PR AIRED BY: Before construction is completed DA 04/27/18 this building will be inspected for compliance with Section 653.908 I her, by certify that ilding, as designed, is in compliance Florida Statutes. with a Florida ergy Cod G'Op WE OW ER/AGENT: BUILDING OFFICIAL: DA DATE: mpliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as tified factory -sealed in accordance with R403.3.2.1. npliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an lope leakage test report with envelope leakage no greater than 5.00 ACH50 (111402.4.1.2). ' 8 12:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 Ill D nR_01147 PROJECT i Title: � Buildi I Type: Owner Name: # of U its: Builde � Name: Permi � Office: Jurisd tion: Famil Type: New/ isting: Com ant: MW 56 User 1 Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1832 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address ! 2664 CONIFER DR St. Lucie FORT PIERCE, FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 , 70 75 299 62 Low BLOCKS Nu ber Name Area Volume 1 Block1 1832 17037.6 SPACES Nil bar Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1832 17037.6 Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0 1832 ft2 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Ell Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Flat tile/slate 2049 ft2 0 ft2 Medium 0.45 N 0.9 No 0 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 i Full attic Vented 150 1832 ft2 N N I, CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type, 4 1 Under Attic (Vented) Main 30 Batt 1832 ft2 0.1 Wood 72018 12:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 i A rnone o 1nr,-*'.)1)17 - • • .I�'-- -- WALLS Adjacent Cavity Width Height Sheathing Framing Solar Beiow Wall Type Space R-Value-Ft-In Et In area R-gkm Fraction-Absnr Grad " 1 N Exterior Concrete Block - Ext Insul Main 4 43 7 9 4 406.8 ft2 0 0 0.3 1 0 2 E Exterior Concrete Block - Ext Insul Main 4 58 0 9 4 541.3 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insul Main 4 19 6 9 4 182.0 ft2 0 0 0.3 0 4 W Exterior Concrete Block - Ext Insul Main 4 53 10 9 4 502.4 ft2 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 2 9 4 197.6 ft2 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft2 0 ft 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft2 0 ft 0 in 0 ft 0 in None None 3 In 1 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft2 0 ft 0 in 0 ft 0 in None None 4 e 2 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft2 0 ft 0 in 0 ft 0 in None None 5 e 2 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft2 0 ft 0 in 0 ft 0 in None None 6 s 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 0 ft 0 in 0 ft 0 in None None 7 w 4 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 0 ft 0 in 0 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 0 ft 0 in 0 ft 0 in None None 9 W 4 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 583 ft2 583 ft2 64 ft 9.3 ft 1 II INFILTRATION # Scope Method SLA CFM 50 ELA EgLA - ACH ACH 50 1 holehouse Proposed ACH(50) .000295 1419.8 77.95 146.59 .2157 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block 'Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 18 12:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 Cnonn D nr,_')n47 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 36 kBtulhr 1080 cfm 0.7 1 sys#1 II HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — - Supply -- --- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat, Cool 1 Attic 6 592 ft2 Attic 414 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Prog tmable Thermostat: Y Ceiling Fans: Cooli Heati 9 HJan Jan Feb HFeb Mar � Mar [ ] A r [ [ ] Apr [ Ma rl Jun [X Jul May Jun [ Jul [X] Au [ ] Auf Se Sep Oct Oct Nov Nov Dec Dec Venti Jan Feb X Mar [X] A r [ Ma Jun [ Jul [ ] Aug [ Se [X] Oct Nov Dec Therm stat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coolin (WD) AM 78 78 78 78 78 78 78 78 80 80 80 -80 PM 80 80 78 78 78 78 78 78 78 78 78 .78 Coolin • (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 '78 Heati (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heati (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 18 12:47 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM 405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 95 The lower the EnergyPerformance Index, the more efficient the home. 2664 CONIFER DR, FORT PIERCE, FL, 34951 1. New nstruction or existing New (From Plans) 9. Wall Types Insulation Area 2. Singl ' family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft2 b. Frame - Wood, Adjacent R=11.0 197.56 ft 3. Num er of units, if multiple family 1 c. N/A R= ft2 4. Num ' er of Bedrooms 2 d. N/A R= ft2 5. Is thi a worst case? No 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1832.00 ft2 6. Con itioned floor area (ft2) 1832 b. N/A R= ft2 7. Win ows•` Description Area c. N/A R= ft 2 a. U11 Factor: Dbl, U=0.62 Ducts 263.67 ft2 a. a. Sup: Attic, Ret: Attic, AH: Main R ft 2 6 592 S GC: SHGC=0.26 b. Factor: N/A ft2 S GC: 12. Cooling systems kBtu/hr Efficiency C. Factor: N/A ft2 a. Central Unit 36.0 SEER:16.00 GC: d. 0 Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency GC: a. Electric Strip Heat 27.0 COP:1.00 Are' Weighted Average Overhang Depth: 0.000 ft. Are Weighted Average SHGC: 0.260 8. Flo r Types Insulation Area 14. Hot water systems Cap: 50 gallons I a. ab-On-Grade Edge Insulation R=0.0 1832.00 ft2 a. Electric EF:0.94 b. i R= ft2 C. A R= 1 ft2 b. Conservation features None 15. Credits Pstat in Buil Add (that this home has complied wi the Florida Energy Efficiency Code for Building uction through the above energ saving features which will be installed (or exceeded) home before final inspection. O erwise, a new EPL Display Card will be completed on installed Code compliant fe ures. Signature: Date: -i2i 1 ;s of New Home: City/FL Zip: cool ,--'> y-7s 1 Jote: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient ortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at chsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of .rtified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building :)mmission's support staff. required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/27/2018 12:47 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 -- rightsoft® Load Short Form Entire House For: MW-56 2664 CONIFER DR, FORT PIERCE, FL 34951 Htg Clg Outside db (°F) 43 91 Inside db (° F) 70 72 Design TD (OF) 27 19 Daily range. - L Inside humidity,(%) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT ake ade odel HRI ref fficiency eating input eating output emperature rise ctual air flow it flow factor tatic pressure pace thermostat 100 EFF 7.3 kW 24817 Btuh 99 °F 1167 cfm 0.047 cfm/Btuh 0 in H2O Method Construction quality Fireplaces i I Job: Date: Apr 24, 2018 J By: II Infiltration Simplified Average 0 I COOLING EQUIPMENT Make Carrier Trade 16 SEER PURON AC Cond CA16NA036****A Coil FV4CNB006 AHRI ref 4584643 Efficiency 13.7 EER, 16.5 SEER Sensible cooling 24500 Btuh Latent cooling 10500 Btuh Total cooling 35000 Btuh Actual air flow 1167 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.66 ROOM NAME III Area (ftz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) ASTER SUITE 312 5079 3609 239 179 HER WIC 60 941 425 44 21 MASTER BATH 169 1815 2142 85 106 BED 2 205 2427 3224 114 160 UTILITY 72 599 907 28 45 BATH 2 79 78 215 4 11 FOYER 100 792 599 37 30 DINING 130 3727 3259 175 161 KITCHEN 151 1770 2217 83 110 DEN 179 3847 3120 181 155 nE3CAT ORS 07n 13-7nn nenn 41 A^'A Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + WrightSOfi• RlghtSuite® Universal 2012 12.1.05 RSU02818 Z\ C:\Users\Jason\Documents\Wdghtsoft HVAC\MW-56.rup Calc = MJ8 Front Door faces: S 2018-Apr-24 65:43:08 Pagel 1 EntIe House 1831 24800 23546 1167 1167 Other equip loads 0 0 Eq Ip. @ 0.95 RSM 22487 Lat, nt cooling 12153 T Al [ I nAOI%n I nACAA I 44L07 I 44.27 i Date; Summary Pro ect -j=�- � rightsoft�' J • � Date: Apr 24, 2018 i Entire House By: I For: Notes: MW-56 2664 CONIFER DR, FORT PIERCE, FL 34951 Weather: Winter Design, Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 21595 Btuh Ducts 3205 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 24800 Btuh Infiltration Vero Beach Municipal AP, FL, US Summer Design Conditions Outside db 91 OF Inside db 72 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Sensible Cooling Equipment Load Sizing' Structure 20108 Btuh Ducts 3438 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2) 1831 1831 Volume (ft.) 18087 18087 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 115 60 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 19 OF 1167 cfm 0.047 cfm/Btuh 0 in H2O Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 22487 Btuh Latent Cooling Equipment Load Sizing Structure 10617 Btuh Ducts 1536 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 12153 Btuh Equipment total load 34640 Btuh Req. total capacity at 0.70 SHR 2.7 ton Cooling Equipment Summary Make Carrier Trade 16 SEER PURON AC Cond CA16NA036****A Coil FV4CN13006 AHRI ref 4584643 Efficiency 13.7 EER, 16.5 SEER Sensible cooling 24500 Btuh Latent cooling 10500 Btuh Total cooling 35000 Btuh Actual air flow 1167 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.66 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Apr-24105:43:08 + wrightsoft' Right -Suite® Universal 2012 12.1.05 RSU02818 page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\MW-56.rup Calc = MJ8 Front Door faces: S COV. PATIO t0x10x8 161 CFM 10xto x8 190 CFM 1113H 10 x 1ox8 i6•x16• 179 CFM ® RAG. W/ 12'O FLEX t2l 6x MASTER SUITE cFM I 10 x 10 x 8 IV VN 155CFM KITCHEN 7110CFM rool DEN R.A.G. RAG. B'A F EX FLEX 0 PORCH lro s•A FOYER AHU-t 6x6x5 3-TON 30 CFM GREAT ROOM 9'AR"60.,x5 45 CFM a•A ® UTILITY I 2 4 R ®� 4.0DRYER TWO BAY GARAGE 6x6 1 EXHAUST 11 CFM so cFM FLEX L O O 12"k 12• �an 8Y vo a y� W/8aa 6-o FLEX BEDROOM 2 L•A Bx8x6 4 50 CFM 86 CFM 6 EXHAUST 20 C 50 CFM GOLF CART Exfts-t0x10x8 160 CFM O Y/ cu-t 3-T0N NOTE: ALL RETURNS SHALL HAVE DIRECT DUCTING TO RETURN A02 PLENUM BOX DO NOT SCALE PLANS OOL T [O M LL LL _L c1C 11J LLI � O OW O V NLL