HomeMy WebLinkAboutBUILDING PLANSPROJECT LOG j ISSUED FOR START 03-3030-18 ISSUED FOR PERMIT 05-08-18 a GENERAL NOTES 1. THIS PLANS WERE PREPARED USING THE 2017 FLORIDA BUILDING CODE 6TH EDITION 2. TYPE OF CONSTRUCTION: CLASS V, UNPROTECTED, GROUP R3 OCCUPANCY PER FLORIDA BUILDING CODE. 3. CONSTRUCTION SHALL FOLLOW THE FLORIDA BUILDING CODE AS ADAPTED BY THE COUNTY AND ALL APPUCABLE AMENDMENTS, 4. THESE PLANS, AS DRAWN AND NOTED, COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY. 5. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER STRIPPED. WINDOW UNITS SHALL DISPLAY LABELS SHOWING COMPUANGE WITH THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY SECTION. 6. REGISTERED BAITING SYSTEM FOR TERMITE TREATMENT TO BE INSTALLED AND MONITERED THIRD PARTY PRIOR TO FINAL BUILDING APPROVAL PER F.B.C. 2017 ABV ABOVE AFF ABOVE FINISHED FLOOR AHU AIR HANDLER UNIT B.F. BI FOLD B.P. BI PAS BLK. BLOCK BLW. BELOW BRG. BEARING BTM. BOTTOM CLG. CEILING CMU CONCRETE MASONRY UNITS COL COLUMN CONIC. CONCRETE CSMT. CASEMENT DBL. DOUBLE DIA. DIAMETER DISP. DISPOSAL DP DESIGN PRESSURE DR. DOOR DW DISH WASHER E.E. EACH END ELEC. ELECTRICAL ELEV. ELEVATION E.S. EACH SIDE E MASONRY NOTES PLAN NOTES FRAMING NOTES ELECTRICAL NOTES 1. CONCRETE UNITS TO BE ASTM C 90-90. ASTM GRADES NI OR NIT. PROVIDE PRECAST UNTELS AS NECESSARY. (fm = 1500 PSI) 1. PROVIDE 1x2 P.T. FlRESTOP HORIZONTAL 0 CEILING & WALL INTERSECTIONS OR 8'-0" O/C 1. THE TRUSS LAYOUT SHOWN ON THIS SHEET IS SCHEMATIC IN NATURE HOWEVER, THE 1. CONTRACTOR SHALL VERIFY WITH ELECTRIC PROVIDER THE LOCATION OF SERVICE AND VERT. MAX. AND ALL OTHER LOCATIONS PER F.B.C. SECTION 718 SUPPORTING SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THAT THE SHALL LOCATED METER & PANELS AS REQUIRED. THESE PLANS WERE PREPARED 2. MORTAR TYPE M PER ASTM C 270-92. FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. 2. ALL GLAZING WITHIN 24° AND PARALLEL TO A DOOR SHALL BE TEMPERED. 2. ALL WIRE SHALL BE THHN COPPER. UNLESS NOD OTHERWISE. USING THE 2017 FLORIDA BUILDING CODE 6th EDITION 3. CELLS, UNTELS AND BOND BEAMS WHERE SPECIFIED SHALL BE FILLED W/ 3000 PSI PEA ALL WINDOWS OR GLASSENCLOSURES AT OR WITHIN 36" OF TUBS AND SHOWERS NTHSILLS 2. THIS FRAMING SCHEME (DIRECTION OF TRUSSES, MAJORG.T. BEARING POINTS, ETC.) CAN GRAVEL CONCRETE. +. LESS THAN 60" ABOVE FLOOR SHALL BE TEMPERED. ALL GLASS IN SIDELIGHTS, SUDING GLASS BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM THE PRIME PROFESSIONAL R 3. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE DOORS AND FRENCH DOORS SHALL BE TEMPERED. RECORD WHO MUST RENEW PROPOSED CHANGES AND AUTHORIZE STRUCTURAL REVISIONS COPPER OF EQUAL AAPACITY. 4. REINFORCING: ACCORDINGLY. 3. EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS. 4. ALL BRANCH CIRCUITS IN. RACEWAY OR NON METALUC SHEATHED CABLE. VERTICAL: EGRESS WINDOWS SHALL HAVE A MINIMAL NET OPENING OF 2e HIGH, 20" WiDE, AND MIN. NET 3. FINAL SIGNED AND SEALED ENGINEERED TRUSS DESIGN MUST BE SUBMITTED TO THIS AREA OF 5.7 S.F. FOR 2nd FLOOR WINDOWS AND 5.0 S.F. FOR 1st FLOOR WINDOWS. THE OFFICE FOR REVIEW. TRUSS DESIGNERS MUST PROVIDE ALL TRUSS CONNECTIONS AS PART R 5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. A. ASTM A615-94 PER REINFORCING SECTION (GRADE 60). BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR. THE DESIGN. 8. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER B. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, IT SHALL NOT BE 4. IN AREAS OTHER THAN HVHZ FIXED GLASS THICKNESS SHALL COMPLY WITH SECTION 2411 4. TRUSS MANUFACTURER. SHALL SUBMIT THREE (3) COPIES OF SHOP DRAWINGS AND - SPECIFICATIONS. SLOPED MORE THAN ONE HORIZONTAL IN SIX VERTICAL ALIGNMENT, EVEN THOUGH IT IS IN AN F.B.C. AS THE MINIMUM THICKNESS ALLOWED. ENGINEERING CALCULATIONS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER, OFOF ADJACENT CELL TO THE VERTICAL WALL REINFORCING. THEIR ROOF TRUSS DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR ARCHITECTS REVIEW 7. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS. C. VERTICAL REINFORCING STEEL SHALL HAVE A MINIMUM CLEARANCE R ONE-HALF INCH FROM 5. PROVIDE A MINIMUM OF 4" CLEAR ALL AROUND AIR HANDLER UNITS. PRIOR TO FABRICATION. REVIEW OF TRUSS SHOP DRAWINGS IS A COURTESY BY THE ARCHITECT AND IN NO WAY RELIEVES THE TRUSS MANUFACTURER OF HIS RESPONSIBILITY TO 8. PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIP. AND AT THE MASONRY. PROVIDE A LAYOUT THAT FULLY INTEGRATES WITH THE ARCHITECTS SUPERSTRUCTURE IF PUMPS NOT VISIBLE FROM CIRCUIT BREAKER P 6. ALL DWELLING ROOMS MUST HAVE HVAC RETURNS. RETURNS MAY BE DUCTED, JUMPERS R THERE IS ANY CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRUSS COMPANY SHALL AN L AND AS PER MANUFACTURER. RECOMMENDATIONS. EXT. EXTERIOR M.C. MEDICINE CABINET SMS SHEET METAL SCREWS D. VERTICAL REINFORCING SHALL BE S LOCATED ON THE PLAN AND AS INDICATED IN THE TRANSFER GRILLES. NOTIFY THE ARCHITECT IN WRITING OF THE SPECIFIC AREAS OF CONCERN. F.B.C. FLORIDA BUILDING CODE M.R.H. MEAN ROOF HEIGHT ST. STIRRUPS COLUMN SCHEDULE. 9. PROVIDE GFl BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS F.R. FIRE RATED M.T. METAL THRESHOLD STL STEEL 7. A/C UNITS MAY HAVE CONC. PAD OR OTHER APPROVED MATERIAL EXTENDING ABV, 5. TRUSSES TO BE DESIGNED TO CARRY LOADS OF ATTIC AHU AND MISC. EQUIPMENT. SHOWN ON PLANS, FR FRENCH DOOR MAX. MAXIMUM SW SWITCH E. VERTICAL REINFORCING EACH SIDE R ANY OPENING, IF REQUIRED, SHALL BE CONTINUOUS ADJOINING GRADE OR SHALL BE SUSPENDED A MIN. OF 6" ABV. ADJOINING GRADE.. COORDINATE LOCATIONS WITH BUILDER PRIOR TO FABRICATION AND INDICATE ON TRUSS FIN. FINISHED MFR. MANUFACTURER TEMP. TEMPERED TO THE TIE BEAM. PRECAST UNTELS SHALL HAVE OPENINGS TO ALLOW REINFORCING BARS TO DRAWINGS. 10. ELECTRICAL FIXTURES, TRIM AND APPUANCES SHALL BE ILL APPROVED AND AS FL FLOOR MICRO. MICROWAVE T.B. THROUGH BOLT CONTINUE UNINTERRUPTED, SELECTED BY BUILDER. G.T. GIRDER TRUSS MIN. MINIMUM T.O. THROUGH OUT HORIZONTAL BEAM SCHEDULE NOTES 6. ALL INTERIOR LOAD BEARING PARTITIONS TO BE CONSTRUCTED WITH CLIPS, TOP AND GA. GAUGE M.O. MASONRY OPENING T.O.B.B. TOP OF MASONRY BOND BEAM BOTTOM EACH STUD, AS PER CODE. 11. PROVIDE PRE -WIRED TELEPHONE OUTLETS AS SHOWN ON PLAN. GFI GFl GALVANIZED ROUND FAULT INTERRUPT MONO. MTL METAL IC METAL T.O.PL T.O.TIPT.B. TOP OF WOOD PLATE TOP R TIE BEAM A. HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SCHEDULED IN THE BEAM SCHEDULE. 1. ALL COMPOSITE LINTEL (MARK %L) TOP BARS SHALL BE CONTINUOUS UNLESS OTHERWISE NOD 7. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE "TIMBER CONSTRUCTION 12. PROVIDE PRE- 'MOPED T.V. OUTLETS FOR CABLE AS SHOWN ON PLANS. GL. GWB GLASS GYPSUM WALLBOARD 0/C a/c OVER HEAD DOOR ON CENTER U.N. U.N.O. TYPICAL UNLESS NOD OTHERWISE 5. GENERAL: -BB-) MANUAL" AS PUBLISHED BY THE AMERICAN INSTITUTE OF UMBER CONSTRUCTION. 13. DEDICATED CIRCUITS SHALL HAVE NO MORE THEN 8 DUPLEX RECEPTACLES. GYP. BD. GYPSUM WALLBOARD P.L.F. POUNDS PER LINEAR FOOT UL UNDERWRITERS LABORATORIES 2 ALL BOND BEAMS MARK ( )REINFORCING SHALL BE CONTINUOUS THROUGH BOND HGT. HEIGHT P.S.F. POUNDS PER SQUARE FOOT V.I.F. VERIFY IN FIELD A. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530-05/ AS.C.E. BEAMS ONLY. ALL SPLICES TO BE A MINIMUM R 48 BAR DIAMETERS. B. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. 14. IN KITCHENS, DINING ROOMS AND BATHROOMS, RECEPTACLE OUTLETS FOR COUNTER HPS. HOOPS P.S.I. POUNDS PER SQUARE INCH W.A. WEDGE ANCHORS 7-10/T.M.S. 402-05, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER CEMENTITOUS MATERIALS AND THE WOOD AS PER CODE. SPACES SHALL BE GFCI PROTECTED ACCORDING TO NEC 210-8(a). HR HOUR P.T. PRESSURE TREATED W/ WITH COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. 3. BOND BEAM SCHEDULE DEPTHS ARE MINIMUM AND MAY BE INCREASED 8" TO FIT BLOCK HS HV11Z HORIZONTAL SLIDING HIGH VELOCITY HURRICANE ZONE PAR7'N. PKT. PARTITION POCKET WC WD. WATER CLOSET WOOD B. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530.1-05/A.S.C.E. 7-10/T.M.S. 602- WORK' 9. CARPENTER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND BRIDGING USED 15. ALL CLOSET UGHTING SHELL COMPLY WITH NEC SEC. 410.8. INS. INSULATION PLYWD.. PLYWOOD 05, SPECIFICATIONS FOR MASONRY STRUCTURES AND THE COMMENTARY ON SPECIFICATIONS 4. REFER TO CONCRETE NOTES FOR INFORMATION ON CONCRETE AND STEEL SPECIFICATIONS, DURING ERECTION OF TRUSSES TO PREVENT COLLAPSE OR DAMAGE. 16. SMOKE DETECTORS SHALL BE CONNECTED TO KITCHEN OR BATH LIGHTING CIRCUITS INT. INTERIOR R.O. ROUGH OPENING FOR MASONRY STRUCTURES, 10. HEADERS FOR FRAMED OPENINGS GREATER THAN 6'-0" MUST BE ENGINEERED AND AHEAD OF SWITCH AND HAVE SELF CONTAINED BATTERY BACK-UP. DETECTORS SHALL BE I.G. LIN. LONG LINEN S.C. S.G.D. SOLID CORE SLIDING GLASS DOOR 6. VERTICAL CELLS FOR MASONRY TO BE ROUTED SHALL HAVE VERTICAL ALIGNMENT CONCRETE NOTES STAMPED BY THE TRUSS MANUFACTURER. (UNLESS NOTED 01HERWTSE) TANDEM WIRED SO ALL DETECTORS SOUND SIMULTANEOUSLY. LT. LIGHT SF SQUARE FOOT SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED CONT. CELL 17. PREWIRE FOR GARAGE DOOR OPENER SENSOR. L.T. LAUNDRY NB SH SINGLE HUNG 7. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF ROUTED CELLS AT EACH 1. CONCRETE SHALL CONFORM TO ASTM C94 -94 AND SHALL HAVE STRENGTH IN 28 DAYS AS 11. ALL NOTED. HEADERS DOORS (F WOOD FRAMECONSTRUCPON DEPENDING ON 3IESOTHERWISE R ON ALL WALL W THICKNESS). 18. ARC FAULT -INTERRUPTER PROTECTION PER LIFT OVER 4'-0" HIGH CLEANOUTS SHALL BE SEALED AFTER CLEANING AND INSPECTION AND SPECIFIED IN THE FOUNDATION AND MASONRY NOTES (UNLESS NOTED OTHERWISE) ALL NEC 210.12. REQUIRED FOR ALL 120-VOLT, ST LUCIE COUNTY PRODUCT APPROVAL OPENING SCHEDULE: DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS OPEN ID PRODUCT -OVERHEAD MODEL # MANUF. GLASS ATTACH. METHOD TYPE, SIZE, SPACING *FILL BUILDING DESIGN PRODUCT DESIGN DESCRIPTION AND EMBED. ALL MANUF. HOLES PRESSURE PRESSURE A FL-9174.10 Rig 9100 OHD 16070 WAYNE DALTON N/A W/ 1-1/4" WASHER & 2-3/4' MIN. EMBED. D.P= +28.4 PSF +39.2 PSF -43.7 PSF 2-3/4* MIN. EDGE DISTANCE 6' FROM END -34.7 PSF B FL-7630.1 3080 j UTE DR THERMA TRU SGL IMPACT 1/4" TAPCONS W/ 1-1/4' MIN. EMBED CORNERS 0 D.P = +31.9 PSF +50.0 PSF -50.0 PSF 6' & 14" O/C MAX. SPACING, -34.7 PSF C FL 17499.1 SH 36 MI WINDOWS & DRS SGL IMPACT 3/18' TAPOONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX. SPACING & 2- FROM EDGE -34.7 PSF D FL 17499.1 SH 25 MI WINDOWS & DRS SGL IMPACT 3/18" TAPOONS W/ 1-1/4- MIN EMBED D.P.= +31.9 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX. SPACING & 2" FROM EDGE -34.7 PSF E FL 17499.1 SH 15 MI WINDOWS & DRS SGL IMPACT 3/16` TAPODNS W/ 1-1/4' MIN EMBED D.P= +33.4 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX RACING & 2" FROM EDGE -36.3 PSF F FL 17499.1 SH 15 MI WINDOWS & DRS SGL IMPACT 3/16' TAPCDNS W/ 1-1/4" MIN EMBED D.P = +33.4 PSF +55.0 PSF -55.0 PSF 0 10" O/C MAX. SPACING & 2" FROM EDGE -44.8 PSF G FL 17499.1 (2) SH 26 MI WINDOWS & DRS SOL IMPACT 3/16` TAPOONS W/ 1-1/4' MIN EMBED D.P= +29.9 PSF +55.0 PSF -55.0 PSF 0 10° O/C MAX SPACING & Y FROM EDGE -37.7 PSF H FL 22401.3 12080 SGD MI WINDOWS & DRS SGL IMPACT 3/16' TAPCDNS W/ 1-1/4' MIN EMBED D.P= +28.4 PSF +55.0 PSF -55.0 PSF 012' O/C MAX SPACING -31.2 PSF I FL 17499.1 (2) SH 25 Al WINDOWS & DRS SGL IMPACT 3/16' TAPOONS W/ 1-1/4" MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 10- O/C MAX SPACING & 2' FROM EDGE -34.7 PSF J FL 15349.5 6020 TRANSOM MI WINDOWS & DRS SGL IMPACT 3/16' TAPCNS W/ 1-1/4' MIN EMBED D.P= +33.4 PSF +55.0 PSF -55.0 PSF EQUAL SPACING & 3" FROM EDGE -36.3 PSF K FL 17499.1 SH H33 Al WINDOWS & DRS SOL IMPACT 3/16" TAPCNS W/ 1-1/4" MIN EMBED D.P = +33.4 PSF +55.0 PSF -55.0 PSF 0IV O/C MAX. SPACING & 2" FROM EDGE -36.3 PSF L FL 17499.1 SH 35 MI WINDOWS & DRS SGL IMPACT 3/16" TAPOONS W/ 1-1/4' MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 010" O/C MAX SPACING & 2" FROM EDGE -34.7 PSF M FL-9174.10 R12 9100 OHD 6070 WAYNE DALTON N/A W/ iATI -1/4- WASHER & 2-3/e MIN. EMBED. D.P= +29.9 PSF +39.2 PSF -43.7 PSF 2-3/4' MIN. EDGE DISTANCE. 6' FROM END -32.7 PSF N FL 17499.1 SH 26 MI WINDOWS & DRS SGL IMPACT 3/16- TAPCNS W/ 1-1/4- MIN EMBED D.P= +31.9 PSF +55.0 PSF -55.0 PSF 0 10° O/C MAX SPACING & 2" FROM EDGE -34.7 PSF 0 FL 17499.1 SH 26 Al WINDOWS & DRS SGL IMPACT 3/16" TAPCNS W/ 1-1/4' MIN EMBED D.P.= +31.9 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX. SPACING & 2" FROM EDGE -34.7 PSF PRODUCT MODEL # MANIUF. ATTACHMENT METHOD BUILDING DESIGN PRODUCT DESIGN M& DOOR TYPE, SIZE, SPACING, EMBED., STIFFENERS, ETC PRESSURE PRESSURE MULLIONS FL 15353.3 MAX. 104-Ile HORIZ. (DOWS4)"FAS1DffRSTAPCDNS WP/ER CLIP"TOP BMIN � 37.7 PSF 54.0 PSF -54.0 PSF FL 15353.4 83" ROOFING NDIA NO. 17-0822.13 EAGLE ROOFING (2) iDd RING SHANK NAILS -83.4 psf -172 psf. BEL-AIR CONCRETE TILE PRODUCTS ROOFING UNDERLAYMENT 0. NOA N17-0614-.22 O. 17-AYMENT POLYGLASS USA MEMBRANE: POLYSTICK TU MAX SELF ADHERED 1 OR MORE PLIES NAILS AND TIN CAPS 12" GRID, 6' O.C. AT A MIN. 4" N/A N/A PFFI At STINK SAS INC. HEAD LAP SIDING STUCCO NIA N/A N/A N/A 2 RING SHANK ATTACHED TO UNDERSIDE R TRUSS SOFFIT STUCCO N/A SPACED 0 EVERY HI RIB (e 0/C) W/ 1-3/4' EMBED. N/A N/A PER NAIL BEFORE GROUTING. CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318-11 AND ACI 301-05. ALL 12. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE. NO. 2 OR BETTER AND SHALL PROVIDE SINGLE PHASE 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS DWELLING UNIT$. CONCRETE MASONRY WORK SHALL BE IN ACCORDANCE VWTH ACI 530-11. ALLOWABLE STRESS VALUES OF 1200 PSI IN BENDING FOR A SINGLE MEMBER USES. 90 PSI-. 19. CARBON MONOXIDE DETECTORS REQUIRED WITHIN 10' OF ANY SLEEPING ROOM. FOUNDATION NOTES 2. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE: SLABS ON VAPOR BARRIER - IN HORIZONTAL SHEAR AND SHALL HAVE A MODULES ELASTICITY OF 1600 KSI R BETTER, AS DETERMINED BY AN APPROVED LUMBER GRADING AGENCY. 31e BEAMS AND - 1 1/2" FORMED CONCRETE BELOW GRADE-2- UNFORMED 1. FLOOR SLAB TO BE 4" THICK POURED CONCRETE SLAB WITH FlBERMESH CONCRETE BELOW GRADE 13. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 2x4 0 24" D.C. PLUMBING NOTES ON 0.006 VISOUEEN (OR EQUAL) N CLEAN WELL COMPACTED FILL STUDS, WITH 1/2" GYPSUM DRYWALL EACH SIDE ATTACH DRYWALL WITH 1' LONG 3. REINFORCING STEEL- GRADE 60 (FY=60.000) ASTM A615-94. BUGLE HEAD DRYWALL SCREWS AT 12' O/C MAX. 1. ALL PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 405, F.B.C. 2. ALL REINFORCING STEEL TO BE GRADE 60. 4. DETAIL OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH "THE MANUAL R 14. METAL LATH OVER SHEATHING SHALL BE 3/8" V-GROVE OR DIMPLED. FASTEN TO 2. ALL PLUMBING FIXTURES SHALL MEET THE REQUIREMENTS OF TABLE 604.3, F.B.C. STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION" AS PUBLISHED BY THE SUBSTRATE AT 4" O/C AS FOLLOWS; 3. COLUMN AND WALL CENTERUNES SHALL COINCIDE WITH FOOTING CENTERLINES UNLESS OTHERWISE NOTED. CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERWISE. CONCRETE: 3/4' LONG STUB NAILS W/ 3/8' HEAD. HORIZONTAL AND VERTICAL WOOD 3. DISPOSITION OF RAIN WATER SHALL COMPLY WITH F.B.C. PLUMBING CODE CHAPTER 11. 4. FOOTING DESIGN BASED ON ASSUMED SOIL BEARING CAPACITY R 2500 P.S.F., 5. ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY SUPPORT ALL LOADS DURING CONSTRUCTION. FRAMING MEMBERS W/ NAILS OR STAPLES TO PROVIDE AT LEAST 1-3/4' PENETRATION INTO HORIZONTAL WOOD FRAMING MEMBERS, AND 3 4 'PENETRATION INTO VERTICAL WOOD / " 4. ALL PLUMBING PENETRATIONS MUST BE A MINIMUM 10'-0" FROM ROOF JACKS. FRAMING MEMBERS. ON VERTICAL WOOD FRAMING MEMBERS, COMMON NAILS SHALL BE 5. FILL PLACED WITHIN 5'-0" OF THE CONSTRUCTION PERIMETER SHALL CONSIST OF CLEAN 6. CONCRETE BEAM SIZES MAY INCREASED (8" MAX.) AS REQUIRED FOR ARCHITECTURAL BENT OVER TO ENGAGE AT LEAST THREE STRANDS OF LATH, OR BE BENT OVER A RIB 5. CONDENSATE DRAINS MUST BE:A MINIMUM OF 82' OFF THE BUILDING. WELL GRADED SAND COMPACTED TO ACHIEVE A DETAILS OR FIT BLOCK COURSING, DROP BOTTOM OF TIE BEAM AS REQUIRED AT WINDOW AND WHEN RIB LATH IS INSTALLED. SHEATHING: 14 GAUGE STAPLES 1" LEG, 7/16" CROWN METAL 6. INSTALL CHASE PIPE FOR HVAC. MINIMUM R 95% MODIFIED PROCTOR ASTM D 1557. DOOR BEAMS (28" MAX.) AND ADD 2-#5 BARS BOTTOM IF DROP EXCEEDS 8'. MTL FRAMING: SELF TAPING SCREWS #12 x 1/2' WASHER HEAD STAPLES SHALL NOT BE 6. ALL MONOLITHIC FOOTINGS HAVE BEEN CHECKED TO PREVENT THE USE OF TRANSFER USED FOR SOFFITS OR CEILINGS REIAT NFORCEMENTSHALL BE SUBMITTED, BUT ONLY IF - DOWELS AS7. DOWELS OLUMN AND VERTICALBARSAABOEIENFORCING TO FOOTING WITH SAME SIZE AND NUMBER OF DOWELSANALYSIS 15. PNEUMATIC FASTENERS SYSTEM TO BE HILT] -COIL NAIL PROGRAM. TYPE TO BE CRF 112G MECHANICAL NOTES REQUESTED BUILDING OFFICIAL 1-1/2" LONG AND .120" DIAMETER U.N.O. 7. CONCRETE FOR FOUNDATIONS AND FOOTINGS SHALL BE 2500 PS MIN. B. REINFORCING STEEL SHALL BE LAPPED 48 BAR DIA. MIN. WHERE SPLICED AND SHALL BE WIRED TOGETHER. PROVIDE CORNER BARS SAME SIZE AND NUMBER AS HORIZ. BEAM 16. TRUSS MANUFACTURER SHALL DESIGN TRUSSES TO COMPLY WITH ALL SUPERIMPOSED 1. ALL HEATING, AIR CONDITIONING, REFRIGERATION AND VENTILATION EQUIPMENT SHALL B. DAMAGE PROBABILITIES FROM TERMITE INFESTATION IS VERY HEAVY PER TABLE R301.2(1). REINFORCING AT EACH FACE. LAP 48 BAR DIA. MIN. WIND LOADS PER F.B.C. 2017 6TH EDITION & ASCE 7-10. CONFORM TO THE REQUIREMENTS SET FORTH IN THE "FLORIDA BUILDING CODE MECHANICAL", AND CHAPTER 28 OF THE FLORIDA BUILDING CODE. 9. PLACING DRAWINGS N BAR USTS SHALL CONFORM TO ACI'S "MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION AS BY THE STEEL NOTES GARAGE NOTES CONCRETE REINFRCINGGSTEEL INSTITUTE UNLESS NOTED OTHERWISE,PUBUSHED CONCRETE 10. DAMAGE PROBABILITIES FROM WEATHERING IS NEGUGIBLE PER FBC TABLE R301.2(1). 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATION FOR THE DESIGN, 1. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLD WOOD PROPOSED SINGLE FAMILY RESIDENCE BY: G "ES LO' 0 L`rjul Ln GRENADINE CLUB LOT 56 MEADOWOOD COPYRIGHT 2018 I . 1 _ u ff z ► pier,ii cV El NN ❑ N n to m n 18�" f 36" 52a° 25}" SH 15 SH 25 SH 35 SH H35 FABRICATION AND ERECTION R STRUCTURAL STEEL FOR BUILDINGS" 2005 EDITION. MATERIALS DOORS NOT LESS THAN V* (35 MM) THICK, SOLID OR HONEYCOMB CORE STEEL DOORS NOT SHALL CONFORM TO THE APPLICABLE ASTM SPECIFICATION AS FOLLOWS: SHAPES, PLATES A-3E LESS THAN >V" (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS, BOLTS - A 307-00 TUBULAR - A5OD-O7a GRADE B (42 KSI) 2. DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE 2 WELDED CONSTRUCTION SHALL CONFORM TO THE AMERICAN WELDING SOCIETY "STRUCTURAL.. DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) WELDING CODE". ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE A.W.S. A5.1 E70XX SHEET STEEL R OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE 3. THE. GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LOAD SCHEDULE LESS THAN r (127 MM) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. LOCATION LDS DM PARTN TOTAL GROUND FLOOR 40 50 10 100 SECOND FLOOR 40 15 10 65 ROOF 30 18 0 48 ATTIC 20 10 0 30 111NL ULITIMATE WIND SPEED = 160 m.p.h. BUILDING RISK CATEGORY = II BUILDING DESIGN AS ENCLOSED EXPOSURE = C ROOF DEAD LOAD FOR MIND DESIGN TAKEN AT 10 p.s.f. NOIEL THIS STRUCTURE IS DESIGNED IN ACCORDANCE WITH CHAPTER 16 R THE FLORIDA BUILDING CODE AND ASCE 7-10. DESIGN PRESSURES FOR EXTERIOR DOORS AND WINDOWS ARE NOD N THE ELEVATIONS. WINDOW AND DOOR MANUFACTURERS SHALL MULTIPLY THE GIVEN DESIGN PRESSURES BY THE APPROPRIATE FACTORS TO OBTAIN TEST PRESSURES. THERMA TRU EXTERIOR DOORS 2x P.T. MR Elm M.O. 20 1/8" M.O. 38" M.O. 54 1/e M.O. 27 1/2' M.O. 35 1/4' W M.O. 37 1/4" W M.O. 41 1/4. W M.O. 55 1/2' W M.O. 78 1/2' W X 98 1/2' H ix, 2x, OR 5/4 BOARD 1x, 2x, OR 5/4 BC P.T. WOOD BUCK P.T. WOOD E 38" 70" 38" SH 35 / \ aoryh �1s M TYP. BAY WINDOW X 98 11A H X 98 1/2 H \ X 98 1/2 H X 98 3/4 H EDGE OF SLAB EDGE OF SLAB EDGE OF SLAB \j1 EDGE OF SLAB - Fill h u • �\j 1 I EDGE OF SLAB 2680 EXT DR 2880 EXT DR 3080 EXT DR 3080 EXT DR W/ 14" SIDELITE PR 3080 DR (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) DOOR INSTALLATION NOTE: DOOR BUCKS USED MAY BE 26, 5/4, BOARD OR ix6. CONCRETE SCREWS USED TO SECURE THE DOOR FRAMES TO THE OPENINGS MAY BE ANGLED SUGHTLY WITHOUT APPRECIABLE LOSS IN RESISTANCE. ALL FASTENERS SHALL BE R THE SIZE, LENGTH AND SPACING S REQUIRED IN THE PRODUCT APPROVAL INSTALLATION PROCEDURES. DRAWING INDEX C-1 COVER SHEET A-1 FOUNDATION PLAN A-2 FLOOR PLAN A-3 ELEVATIONS A-4 SECTIONS A-5 STRUCTURAL PLAN A-$ TRUSS PLAN E-1 ELECTRICAL PLAN 1111-1 MECHANICAL PLAN SYMBOLS LEGEND 1 TAIL DETAIL/ u .SCALE 4 Duc INTERIOR SCALE 2 ELEVATION 3 DETAIL DWG. SCALE C# COLUMN LABEL F,# FOOTING LABEL SECTION DWG. SCALE POT SHELF HEIGHT AS NOTED 16 SECTION DROP(!!//!!//1/1/1l//1!E Gwc. SCALE HEGHTEASNOTED -I- FFf0OI�� I:- Z LUl_ ARCHED SEE PLANR ELEV. INTEPoOR ELEV. SCALE MASONRY CONSTRUCTION TYPICAL B# BEAM LABEL ■• GROUT FILLED CELL SEE FOUNDATION PLAN 2# REVISION NON -BEARING FRAME CONSTRUCTION N NORTH ARROW BEARING FRAME CONSTRUCTION Lij 0 v xa J uJLjJ° M = zw J L W D >K U J r z �P v n rn 0 Z o Q N Z v Oa o ❑ O O c c CL n - C1 N O o .fl U c Ln N 2 do ra ou E o a m a�i o c n (u E E o 12 o" C)O E N '6 a U 4] o o v F E fJ O) C CV� Cu O = w oa E O ooCIO Qj sZ a i cn .- i z 0 u Q noo C6 0 'n I✓ 0 r- 0 u im U W C Q 0 _U a�= 2 CVCN 0 `� 2 11 1 t M 11 _ C LTYm4 J W C JD J A a ❑ O ❑ � Lu w r 1�L 5- Ln =1 - BREAK UNE ELEV BEAM HEIGHT CHANGE r r� COVER SHEET SCALE 1�1 �8" l'-D* GRAPHIC SCALE 0'-0" FlN. FL SLAB FLOOR ELEVATION l C=� 17 MW - 56 w 0 0 CL 0 U W LL PROJECT LOG ISSUED FOR START 03-30-18 ISSUED FOR PERMIT 05-08-18 FOOTING SCHEDULE DETAIL MARK SIZE WxD REINFORCING DESCRIPTON NO. W/2 15 CONT. EXTERIOR MONOLITHIC F-1 20" x 18" BTM. ONE STORY 1 W/2 /5 CONT. EXTERIOR MONOLITHIC F-2 20" x 18" BTM. 0 RECESS 38 ISOLATED F-3 3-0" x 3'-D" x 12" W/4 15 BTM. E.W. PAD 7 W/2 15 CONT. F-4 20" x 16" BTU. INTERIOR MONOLITHIC 27 EXTENDED F-5 36' x 20" x 18" W/4 /5 BTM. E.W. EXTERIOR MONOLITHIC 19 THICKENED EDGE TE-1 10' x DROP x CONT. W/115 CONE. AT DROP 34 INT. BEARING WALL SEE FRAMING PLAN TRANSVERSE RESAR ONLY AS READ. SEE FOOTING SCHED. WELDED WIRE MESH CONT. REBAR EQ, L EQ. L SEE F0077NG SCHED. SCH DOLE OMIT CENTER BAR EN ONLY (2) REQ, 27 INT. CONT. MONOLITHIC CONC, POURED FILLED — CELL W/ STL, PER PLAN DOWELL & EPDXY (1) #s REBAR INT❑ SLAB @ FILLED CELL LOCATION W/ 4' MIN, EMBED, INTO SLAB FlBERMESH OR WELDED WIRE MESH (SEE 1 SCHEDULE) MATCHING DOWELS FOR COLUMNS 48 BAR DIA. MIN. W/STD. HOOKS -PAD REBAR SEE FOOTING SCHED. EDGE BARS ALWAYS REMAIN. SPACE OTHERS EQUALLY, 1 y 1=1 =1C G'c � SEE OTHER E0. EQ. DETAILS FOR SEE SCROULE FOOTING BEYOND 2 EXT. MONOLITHIC AT PAD MISSED COLUMN STL. DETAIL TYP, HOLLOW MASONRY BLOCK RUNNING BOND PER PLAN CONC. SLAB & MONOLITHIC FOUNDATION PER PLAN COLUMN SCHEDULE MARK SIZE TYPE DESCRIPTION C-1 8x8 BLOCK CONC. BLK W/1 FULLY GROUTED CELL W/1-15 VERT. EA. CELL 0 8'-0" 0 C MAX. OR AS LOCATED ON PLANS C-2 8x16 BLOCK CONC. BLOCK W 2 FULLY GROUTED CELLS W 1- 5 VERT EA. CELL C-3 8x12 BLOCK CONC. BLOCK W 1 FULLY GROUTED CELLW 2- 5 VERT. C-4 12x12 BLOCK CONC. BLOCK W/1 FULLY GROUTED CELL W/4-15 VERT. 81 MATCHING DOWELS FOR "' CONC. OR MASONRY � COLUMNS 48 BAR DIA. COLUMN MIN. W/STD. HOOKS FlBERMESH ��" .. MATCHING DOWELS ' �� 48 BAR DIA. MIN. FF GRADE W/STD. HOOKS FOOTING REBAR 1, li SEE FOOTING SCHED. 1i:7 it FlBERMESH V. is i A ..z PAD REBAR ED. EQ. SEE FOOTING SCHEDULE SCHED. EDGE BARS ALWAYS SEE SCHER REMAIN. SPACE OTHERS EQUALLY SCHED, TYP. O EXTERIOR CONT. O ISOLATED 38 MONOLITHIC FOOTING PAD EXT. CONT. MONOLITHIC I —o u 1-15 CONT. 3" MIN. COVER 10, 34 THICKENED EDGE #1 w 0 0 g J J Z O W a ° Z 0 Qa 0 o c cu v ' a c co E .`n o fn � 3 d x a (13 c x W 43 0 o +-. -q o 0 E C o acv C: U c O O p C d O E E O m p aO �.. C O N N N C d N O v E N rn iul c p= vvi O O d O ro ruo (� 2f a s 0 "O cu W �--�con a V 2f :D o u W W M� V J 0 Lu 1/4" = 1'-0" U.N.O. FOUNDATION PLAN A-1 MW = 56 (2) #10 S.M.S. TOP & BOTTOM ® EACH STUD FINISHED CEILING - SEE TYP. WALL SECTION 2x6 BLOCKING 0 CABINET LOCATIONS. FASTEN EA. END TO STUDS W/ (2) #10 S.M.S. EA. END 25 GAUGE CHANNEL SHAPED STUDS- (2X4 STUDS ® 16" 0/C) (2x6 STUDS 24" 0/C) W/1 FULL LENGTH LAYER OF 1/2" TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ I" LONG BUGLE HEAD SCREWS TO EACH SIDE ® 12" 0/C CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM CONC. FLOOR SLAB HILTI PINS .145" DIA x i" LG. ® 16- 0/C W/ i" WASHERS TYPICAL INTERIOR PARTITION ALONG CABINETRY BACKING SCALE 3/4" = 1'0" (2) 110 S.M.S. TOP & BOTTOM ® EACH STUD FINISHED CEILING - SEE TYP. WALL SECTION CONT. 25 GAUGE METAL TRACKS TOP & BOTTOM W/ (1) #10 SMS 0 24" 25 GAUGE CHANNEL SHAPED STUDS 24" O/C W/1 FULL LENGTH LAYER OF 1/2" TYPE GYPSUM WALLBOARD APPLIED VERTICALLY & ATTACHED W/ 1" LONG BUGLE HEAD SCREWS TO EACH SIDE 0 12" O/C CONC. FLOOR SLAB HILTI PINS .145" DIA x I " LG. ® 16" 0/C W/ 1" WASHERS ff) INTERIOR PARTITION 3/4" = V-D' R-30 BLOWN —IN FIBER GLASS INSULATION AT ALL A/C AREAS ALL INSULATION SHALL COMPLY WITH FBC R302.10 FLAME SPREAD COMPLIANCE 25. SMOKE DEVELOPED INDEX 50. ALL CEILING AND WALL FINISHES SUCH AS PAINT SHALL COMPLY WITH FBC R302.9.2 AND BE LESS THAN THE VALUE OF 200. CALCULATIONS TOTAL U/A 1832 S. F. COVERED ENTRY 121 S.F. COVERED PATIO 238 S.F. GARAGE 583 S.F. TOTAL AREA 2774 S.F. TOTAL AIR VOLUME CUBIC FT. = 17037.6 GARAGE COUNG (4) 2x4 METAL STUD GARAGE FLOOR ELECT. PANEL / CHASE 6'-6" 0 I g a AC 12" AC CONC. PAD DETAIL N.T.S. OSH 15 1HB °n SH DRYER VENT -4 u� DRYER VENT LOCATION FRONT VIEW 15 O IMPACT / LOW E GLAZING AT WINDOWS AND SLIDING GLASS DOORS 9'-4" T.O.B.B. LO.B.8. SH 25 O W" THK TEMP MELESS GL W/ CLIPS 1/2" WALL CAPS MTL FRAMING KNEEWALL W/ DRYWALL FINISH THIS SIDE PT 2X SILL PLATE TOP OF KNEEWALL W/ PT 2X TOP PLATE & 1/2" PLYWD & 1/2" NON ASBESTOS FIBER CEMENT BACKER BOARD KNEEWALL W/ NON ASBESTOS FIBER CEMENT BACKER BOARD ON SHOWER/TUB SIDE ROMAN SHWR L_L_LL_L LLLLLL LLLLLL TYP. KNEE WALL SECTION 1 /2" - 1 0" FINISHED CEILING 2x WD BLOCKINI EACH SIDE OF I FOR MOUNTING 2x MTL. STUD' TYP. FINISHED FLOOR TYP. MEDICINE CABINET lihil ARCHED OPENING ELETE STANDARD BACKSPLASH DBL OVEN — 0Q 0 � CROWN MOLDING UPPER CAB r4�� 2X4 BEARING WALL - SPRING 0 7'-4" T 08'-0" A.F.F. — — — — P N SEE STRUCTURAL LN N DINING 10'-8" CLG. r 10'-8" CLG. DBL SINK W/ DSP. REF r z O DW _ o ° DEN 9'-4" CLG. N N o ¢ ® n I F COUNTER — — — — 36" AFF-1" 5'-4" 5'-1" 8" C 6 4" ¢ N m ® o N o I PORCH I (2) 2880 PKT DR ® ® = PAVERS ® 9'-4" CLG. N 7'-0° 4'-8" I I o ®w m m CO PATIO FOYER . 0 3081 LITE D O _ - 10'-8" CLG. 0 5'-0 1 2 3'-5 1 10,-8" CLG. a I a $ ® A4 " 2'-0" N GREAT ROOM M i PAVERS A ® 10'-0" ;0 10 -8 CLG. 2 BROOM CLOS. 16070 OHD o \ 6�O ®®® 11 9'-4" C G.8 UTILITYIN6 NLY 2880 g a 9'-4" CLG. 40 FLAT ARCH I N 2'-0" 5'-8" 20 MIN. SOLID CORE I 8'-4" TO 9'-0" 10" �R/A DOOR W RABBITTED SHELF 042" AFF , JAMB OVERSIZEDWEATHER STRIPPING ftttu® ® 40" X 5" M 2880 LO_q'�D LIN., OPT. I TWO BAY GARAGE ® IIIIIIIIIIIIIIIIIHM 680 5 SH. 2'a4" M,3'-2" 2'-4" 3'- N m N 2 • I I (� 2v L--------------�-----J I 0LG. R_& S _ 108' X 5o _ — a • ti J I LINE OF OVERHEAD DOOR ® 0 O °p ® O SPN Fri 6080 BP d x o y IN�31 O6060 x BP B'-2"GARAGE g_15'-0" JE L J SMOOTH COAT. ¢ tO a MASMASONRY . m 5'-10" 8'-0" — LINE OF OVERHEAD DOOR STUCCO FINISH AT EXTERIOR I "� N WALLS. OMASTER SUITE BA BEDROOM 2GARAGESEPARAT10N9'-4 STOP ®NTERIORSDRYWALLTUCCO oa CLG. -4" CLG.w�_nN REQUIREMENTS PER 3 2.6 26'-8°9'-4" R-11 BATT INSULATIO FOR DEMISING I WALL PER ECALCS O ® — — SILL ® 42" o I GOLF CART tPS-4' 00 o W C` ° X 54" FRAME i TE F.G. W 8'-6" 3'-0" '-2 4" 3'-10` I ^ S 08 WH R&S 6020 FG CHANGE IN O (TEMP) CLG. HGT. HEAD ® 8'-0" C RNER SHELVES 0 _ 48" & 60` A.F.F. SH H33 K OBS URE O �a o� F 35 O6070 OHD VSATE DRAIN BE MIN. 12" FROM BLDG PRO] ECT LOG ISSUED FOR START 03-30-18 ISSUED FOR PERMIT 05-08-18 W M 0 m o W # w J H m W z Z a Z o z J Q ° s J K o a ti m m z 0 O° _ 0 0 0 o g QcliE 2- c ro (L) o C E -n -c:s n > = V W = p i =lu EE c a a� Eo�o 0 p V C u N E i Q = Lr) G p o w E O N QC o z 0 Q 0 u O Lo c 0 U im r- 0 V Lu C CD V OJ r = N O CV �6 V � W � U z IGi Q O W � W J Q OJ W (~ 1/4" = V-0" U.N.O. FLOOR PLAN A-2 W-56 PROJECT LOG ISSUED FOR START 03-30-18 ISSUED FOR PERMIT 05-08-18 12 CONC ROOF TILE, TYP. 6 � I I DECORATIVE STUCCO LOUVER I I I I — - 10'-8" T.O.B.B. I - `v I N 9--4" T.O.B.B. LIL W LE � a o LIJ v o 58" THICK MEDIUM TEXTURE _ _l o 8888 I DECORATIVE CEMENTITOUS FINISH w Lu a "' x ON BLOCK WALLS, TYP. w w LL LL N D. +31.9 PSF O D.P.= = +31.9 PSF D.P.= + .9 PSF C ~ Q m m N -34.7 PSF -34.7 PSF - 4.7 PSF 0'-0" FIN. FL. SLAB z J o ----------------------- -- - - - ----- ----------- ¢ 2 0 OD.P.= +31.9 PSF z B -34.7 PSF 0 a FRONT ELEVATION - CLASSIC W/ CONIC TILE ROOF 4. @E.NSo Imo w I I c x lafjl L a o ao -121 1a I I E ' j5 E oC2 —_ 10'-8" T.O.B.B. E 2 o-0 a v 7-v 6 J- a� — - 9'-4" T.O.B.B. o � o c� -- cn rn ; N c =0 vS 0O a oCU ■ U vj O= ❑ Z 0 V '6 p Q m Ll I o 1 I D.P.= + D.P31.PSF I O= +29.9 PSF O -34.77 PSF — ( -37.7 PSF - — - - 0'-0" FIN. FL SLAB 0 ODP- ±31.2 PSF MEDIUM TEXTURE REAR ELEVATION L DECORATIVE CEMENTITOUS FINISH — 0 v CC C ON BLOCK WALLS, TYP. CL ® 0 ^ t UU 0 C _ :e w � a Q G1 r v .- _0J 04 00 r. a=4.0" L a=4.0" a=4.0" G a=4.0" I, I I I I I I I I I I I I I I I I I I hry I I I I I I I I 10'-8" T.D.B.B. — - 9'-4" T.O.B.B_ I I LL- I I I W v Z oI D.P.= +31.9 PSF D.P.= +33.4 PSF D. +33.4 PSF W O-34.7 PSF 36.3 PSF -44.8 PSF U0 O ® I 0'-0" FIN. FL SLAB -- - ------------------------------------- ----- t---------- -- -- -------- JO Lli c~n 28.4 PSF O D.P.= +34.7 PSF MEDIUM TEXTURE RIGHT ELEVATION - CLASSIC 1/4" = 1'-0" U.N.O. DECORATIVE CEMENTITOUS FINISH ON BLOCK WALLS, TYP. ELEVATIONS A-3 �j MW - 56 I b> o I • � O PROJECT LOG ISSUED FOR START 03-30-18 ISSUED FOR PERMIT 05-08-18 6WkOWxN". W 141g0yOIO�IO m,"c" Coco I &(` IO h ;v F 105A i7 454 co'kwcst ) t.-•r-cSssenno y' M'.,r Fo ua 3.. u0 FK'4<%'4%'F Mid Well (M Style) Control Joint Designed to relieve stress and assist in controlling cracks in exterior wall finish. Intersections of Ts available. 1578 SOUL 7I8"x1l2" 3-112" solid flange. 1-314" perforated Flange Mid Well Control Joints— Designed to relieve stress and assist in controlling cracks in exterior wall finish. Intersections of Ts available. US Patent Nmnber 7,767,450 Caulk all intersections, buttjoints., ends and corners at time of installation. ATTIC VENT CALCULATION: (SQ IN) ROOF AREA CALCULATED 0 2774 (SQ.FT.) x 144 = 399,456 SQ IN. / 150 = 2,663 SQ. IN. REQUIRED NET VENT AREA / 15 SQ IN. PER LINEAR FT. (238 LF) VENT = 3,570 SQ. IN. TOTAL NOTE: CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF VENTS FLAT CONCRETE TILE 901 FELT SELF-ADHESIVE UNDERLAYMENT OVER 301 FELT TIN TAGGED TO EXT. GRADE PLYWD. SHEATHING (SEE DIAPHRAGM SCHEDULE FOR TYPE & NAILING PATTERN) PRE-ENG. WOOD ROOF TRUSSES @24' 0/C TYPICAL W/APPROVED GALV. TRUSS ANCHORS EA. END SEE PLAN ELEV. GALV. MTL. DRIP — ON 1X2 P.T. 2x6 PAINTED TEXTURED SPRUCE FASCIA CEMENTITIOUS FINISH ON METAL LATH ATTACHED TO LEDGER & 2x4 BLOCKING W/ 3" CONTINUOUS VENTS ALL SIDES (TRUSS CO. TO PROVIDE FLAT SOFFIT) CEMEMNTITIOUS FINISH OVER 8" CONC. BLOCK R 4.2 BETWEEN STUDS 0'-0" FIN. FL. SLAB tn, 11, 12 6 16 4.0 I l 1 I I I I I I INSULATION PER ENERGY CALC. J RAT RUNS PER " TRUSS MANF. 8" DRYWALL OR 1/2" 'TOUGHROCK" 5rR EQUAL) APPLIED TO UNDERSIDE OF TRUSSES FIRE STOP CONT. 8" 16" MASONRY BOND BEAM W/ 1J5 CONT. TOP & BOT. - FILL W/ CONC. CONT. METAL POUR STOP 1/2" DRYWALL 1X2 P.T. FURRING ® 24" 0/C EXTERIOR BLOCK WALL TO BE WOOD BASE MONO. CONC. FOOTING SEE FOUNDATION PLAN FOR NOTES & DETAILS a � � • �. III —III � • ' • %' .' .III —III —III_ TYPICAL WALL SECTION SCALE 3/4" = 1 Product Submittal Sheet vinylcorp com 6000 N`N 79th Place P 305. 477.9454 Clarkwestern Dlalhdr Building Systems LLC Miem., Florida 33158 F 305A71.4108 Soffit Vents (One Piece) Continuous one-piece Soffit Vent with reinforcing rib to key into stucco &arnp; plaster. W CS58-300V I 518" I 3" wide vent (one piece) 5" overall Moth. perforated flanges 15 3" Soffit Vents —continuous one-piece Soffit Vent with reinforcing rib to key into stucco &ari'P: plaster. Vent Clips are provided to connect Soffit Ventaod to assist In alhgninsit Vent area. 15 square inches per lineal R Caulk allinlersectiens, buttjoints, ends and comers attune of installation. TYPICAL INSTALLATION „ WINDOW ASSEMBLY MARBLE SILL TENERS AS REQUIRED WINDOW MANUFACTURER SEAM AT D.P.= +33.4 PSF O-36.3 PSF J 6'-0" El D.P.= +33.4 PSF 36.3 PSF O rCONTRACTOR TO APPLY TO ALL SIDES OF MASONRY OPENING INCLUDING HEADER AND JAMBS PER FBC 2017 703.4 LIQUID APPLIED FLEXIBLE CONCRETE FLASHING WATER PROOF PRODUCT TO MEET AAMA 714 APPLY PRODUCT DIRECTLY TO CLEAN CONCRETE SUBSTRATE PER MANUF. SPEC +'ad. WINDUW 1NSIALLAII MORTAR OR GRGUT .4 a ° d ... a .� a a• °. 4. SET SILL IN FULL DRYWALL °'A,. -ae' °� °.m "'. <, MORTAR BED AND HEAD JOINT STUCCO OR .p< DECORATIVE .Q a CEMENTITIOUS .tl / COATING 3/4- FURRING TO a MASONRY WALL 4 . B' C.M.U. PRECAST SILL DETAIL CONCRETE WATER PROOFING APPLICATION STUCCO ATTACHED TO METAL LATH ATTACHED TO UNDERSIDE OF TRUSSES RAT RUNS PER TRUSS MANF. (MAX. 8' O.C) IN IN IN IN IN WFUN -I �■I I- COV. PORCH SLOPE All -- -- - — - — 12 6 PSF PSF- — - MEDIUM TEXTURE DECORATIVE CEMENTITOUS FINISH ON BLOCK WALLS, TYP. Lam!! D.P.= +29.9 PSF O -32.7 PSF LEFT ELEVATION - CLASSIC PROVIDE MEDIUM TEXTURE CEMENTITOUS FINISH PRIOR TO METER INSTALLATION - - — 0'_0" FIN. FL SLAB CONIC. OR MASONRY ALUMINUM FRAME 1x4 P.T. BUCK SET IN STUCCO FINISH FASTEN TO BUCK W/ 3/16"x2 1/2" TAPCON SEALANT AND NAILED W/1-1/2" CASE HARDENE PERIMETER CAULKING 2x6 P.T. BUCK SET IN SEALANT FASTEN SCREWS ® 12" 0/C PERIMETER SEALANT COIL NAILS AT 12" 0/C. MAX. CONC. OR MASONRY 1x4 P.T. BUCK SET IN W/ 1/4" DIA. x 3-1/4" SEALANT AND NAILED STUCCO FINISH CONC. OR MASONRY TAPCONS 3" FROM E.E. W/1-1/2" CASE HARDENE J ''.?)°Oo a Q . 'o. AND 12" 0/C MAX. CONC. OR MASONRY Oo COIL NAILS AT 12" 0/C. o q fx4 P.T. BUCK SET IN b:: ' o .`'Oo�.: ' ° is a MAX. DOOR TRIM SEALANT AND NAILED W/1-1/2" CASE HARDENEE DOOR FRAME COIL NAILS AT 12' 0/C. DRYWALL BOARD DRYWALL BOARD FASTEN TO BUCK W/ MAX, CAULKING CAULKING (2) 16 GALV. x 2" '� DRYWALL BOARD ALUMINUM FRAME SCREWS ® 2'-0' O/C FASTEN TO BUCK W/ DOOR FRAME DOOR TRIM CAULKING 3/16" 1/2" TAPCON FASTEN TO BUCK W/ PERIMETER SEALANT SCREWS 012" 0/C (2) 16 GALV. x 2" STUCCO FINISH PERIMETER SEALANT SCREWS ® 2'-O" 0/C STUCCO FINISH HEAD/JAMB DETAIL (DOOR) JAMB DETAIL (WINDOW) HEAD DETAIL (WINDOW) JAMB/HEAD DETAIL (S.G.D.) CONC. COLUMN DOOR THRESHOLD SET WEATHER STRIPPING IN BED OF CAULK & FASTENED TO SILL W/ BY DOOR MANF. GARAGE DOOR ALUMINUM FRAME SECURE FRAME TO SILL J8 x 1 1/2' SCREWS ® 18" O/C PERIMETER CAULKING GALV STL VERT. TRACK BY MANF FASTENED TO TRACK BRACKETS W/ WITH SILICONE CAULKING DOOR FRAME FASTEN TO SILL W/ FLOOR COVERING 1/4"-20x1/2" CARRIAGE x 2" SCREWS BOLTS & LOCK NUTS OOo6 ' o. o' ®2'-0" 0/C a o� °. GALV. STL. TRACK Oa o BRACKETS FASTENED T FLOOR COVERING 0 CONIC. FLOOR SLAB TO WOOD JAMB W/ 6"x1-1/4" 3/1LAG SCREWS 2x8 P.T. ATTACHED TO ` PRECAST OR POURED SILL .07�' ° OQo °o,p O PERIMETER CAULKING MANi METHOD OF COLUMN W/ 5/8" WEDGE PERIMETER CAULKING STUCCO FINISH AR�gHa �N S s BMrrTED ANCHORS ® 2'-0" 0/C VERT. (6- MAX. FROM ENDS) AND GROUT BED w COMPLETE INSTRUCTIONS 2 FROM INSIDE EDGE OF 2X CONCRETE SLAB SILL DETAIL (DOOR) JAMB DETAIL (GARAGE DOOR) SILL DETAIL (WINDOW) SILL DETAIL (S.G.D.) R-30 INSULATION AT AIR CONDITIONED CEILING LOCATIONS PRE ENGINEERED WD. TRUSSES F— @ 24" O/C TYPICAL —> FOYER I I GREAT ROOM 12 6 COVERD PATIO SLOPE — - - —i---- 4 STUCCO ATTACHED TO METAL LATH ATTACHED TO UNDERSIDE OF TRUSSES RAT RUNS PER TRUSS MANF. (MAX. 8' O.C) SECTION A -A -CLASSIC 14_ A 1- FL. SLAB gai ^W do I L on v J J W ti jz � so ° ce na - I w Z Z + 3 co,~ W N _u tno z J o Q tn tn ed o od a m Q N 0 Oa = r'rs 0 0 c � I-- o ra Q au Q— a '� OL O O U '0 a . ca E o lu .N o _ z 81 .,271 v '� C] '6 '� aJ i c=a l s a+'i a ra vi `Z E Q c -p � rn � a (1 a�i E E o O 0 O d L rn W o COD = o ° F- E -0— = =O Z rri C O O a E E _vi o -. + a 2 U _ CJ- o n '� Q V Wv� U_ � LL ZD 0 U W 0 W U a W 1/4" = 1'-0" U.N.O. ELEVATIONS SECTIONS W 56 ENG. AND APPROVED WOOD TRUSS S SEE TYP. WALL SECTION FOR ACTUAL HEEL AND OVERHANG CONDIDONS t CONNECTOR NOTE R. MFR. SPECIFICATIONS _ SEE PLA�ONRY BOND BEAM R STOP LL A5 CONNECTION DETAIL NOTE: MAY BE ATTACHED TO VERICAL TRUSS MEMBER FOR DESIRED INSTALLATION DUE TO TRUSS PROFILE DISCREPANCIES 6 PRE-ENGINEERED WOOD ROOF TRUSS 0 24" 0/C SIMPSON MGT W/ 22-10d NAILS INTO TRUSS CONC. TIE BEAM OR MASONRY BOND BEAM (1) JANC�H�OR INTO BEAM W/ 5" MIN. EMBED. SET IN EPDXY MAX. UPLIFT = 3965# A5 CONNECTION DETAIL PRE-ENG: WOOD TRUSSES SEE TYP. WALL SECTION FOR ACTUAL HEEL AND O.H. CONDITIONS USP HDPT2 OR HDPTD FASTEN TO WALL W/NAILS PER SCHEDULE AS READ. FRAME BEARING WALL ELEV. r. STRAP DBL. TOP PLATE TO STUDS W/ "USP" SPTH 4, 6, OR 8 U-STRAP O R TOP PLATE AND DOWN EACH SIDE W/ (6) 10d NAILS (TYPICAL) W/ WOOD STUDS ® 16' O/C (PER PLAN SOLID BLOCKING ® 4'-0" O/C VERT. MAX. STRAP BOTTOM PLATE TO STUDS W/ "USP' SPTH 4, 6, OR 8 U-STRAP R BOTTOM PLATE AND UP EACH SIDE W/ (6) 10d NAILS (TYPICAL) 5/8" WEDGE ANCHORS 0 24' O/C AND 6" MAX. FROM OPENINGS 6 W/3"x3"xl/4" STEEL WASHERS EMBED 4" MIN. FLOOR SLAB SECTION 4 CONNECTION DETAIL ALLOWABLE UPLIFT A5 Loaos FASTENER TOTAL FASTENERS SIZE 2 4 6 8 10 12 8d 220 440 660 880 1f00 1320 lOd 265 535 800 1065 1333 1500 LOTT'S LINTEL BEAM SCHEDULE 1B/FT LINTEL LENGTH ALLOWED LOAD APPLIED LOAD ALLOWED UPLIFT APPLIED UPLIFT LINTEL SPECIFICATION 1 17'-4" 2106 355 788 247 8F34-1B/1T 2 4'-0" 7729 857 4771 286 BRF14-18/1T 3 5'-4" 5609 157 3057 48 8F16-1B/1T 4 7'-6" 2882 130 1548 97 8F16-1B/1T 5 7'-6" 2882 120 1548 90 81`16-1B/1T 6 7'-6" 2882 355 1548 247 8F16-i8/i1I 7 4'-0" 8859 1270 5572 435 8F76-18/1T 8 3'-6" 10000 1253 9578 436 8F32-16/1T 9 3'-6" 10000 0 9578 0 8F32-i8/11I 10 7'-6" 7857 0 3323 0 8f32-18/iT 11 13'-4" 3250 0 1178 0 Bf32-18/11I 12 10'-6" 1533 423 914 275 BF16-16 1T 13 9'-4" 2000 210 1027 82 8F16-i8/11I 14 14'-8" 1079 217 477 75 8F16-1B 1T 15 7'-6" 2882 271 1548 95 8F16-1B/1T i6 7'-6" 2882 946 1548 330 8F16-1B/1T 17 3'-6" 10000 1841 7428 650 8F16-1B/1T 18 5'-4" 5809 840 3057 291 8F16-1B/1T 19 7'-6" 2882 355 1548 247 8F16-18/1T 20 4'-0" 6859 250 5572 100 8Fi6-18/1T 21 4'-0" 6859 250 5572 100 BF16-18/1T F =FILLED WITH GROUT / U =UNFILLED QUANTITY OF #5 REBAR AT BOTTOM OF UNTEL CAVITY 8F16-1 B/1 T LNOMINAL HEIGHT QUANTITY OF #5 NOMINAL WIDTH REBAR AT TOP Y- TYP. 0 WALLS BUB BFi6-08/lT -�k— 7-5/8" ACTUAL " NOMINAL HEIGHT 8Fi6-iB/iT 8F24-00/1T #5 REBAR AT TOP MIN. (i) REQ'D CLEEAARR C.M.U. GROUT #5 REBAR REINFORCING PROVIDED IN LINTEL (VARIES) BF30-1B/iT (3) 16D TYP. 2 lOd TiP. . TRUSS REINFORCE VERTICAL MEMBERS OF GABLE END TRUSS W/2x4 T-BRACE AT EA. VERT. NAIL w/i6d NAILS ®8" 0/C (w) CONNECTION DETAIL 1/2" DRYWALL OVER TYPICAL FURRING EXTRA LAYER OF 1/2" DRYWALL SURRONDING FRAME ARCH TYPICAL FURRING � APPLIED TO SHEATHING 19/32 PLYWOOD ARCH SECTION IIIII II It (:A!5:) fYINNFfTI(1N IIFTAII ROOF SHEATHING NAIL PER SCHEDULE CONT. FASCIA BOARD (SEE WALL SECTION) NAIL TO LADDER W/ i6d ®8' 0/C 2x4 (ADDER FOR O.H. ®12" 0/C �16V" MAX CONT. 2x4 LADDER PLATE ANCHORED TO GE TRUSS W/ 16d NAILS 08° 0/C MAX. �— 20 DIAGONAL BRACE RESTRAINT ®4'-0" 0/C WALL SHEATHING NAIL PER SCHEDULE GABLE END FASTEN TO SLEEPER W/ i6d NAILS ® 4" 0/C TYPICAL CONT. 20 SLEEPER FASTEN TO BEAM W/ HILT( XDNI 2-5/8" LG. ®6" 0/C LISP TA24R EMBEDDED STRAP W/ (4) 16d NAILS ® EA. TRUSS VERT. WEB (24' 0/C) CONT. CONC. OR MASONRY TIE BEAM SEE TIE BEAM SCHEDULE 2x4 LATERAL BRACING ®4'-0" 0/C CONT. 2x6 P.T. BUCK FASTENED TO LINTELS W/ 1/4"x3" LG. TAPCONS ®12' 0/C MAX. AND TO BLOCK OR CONC. �-W/ HILT( DNI-62-P8 ®8" 0/C MAX. 2X6 P.T. CROSS BLOCK REQUIRED ONLY IF ' FREE EDGE DIMENSION EXCEEDS 240 SEE DIMENSION. NAIL TO BUCK AT EACH END W/ (4) 16d NAILS. EDGE OF MASONRY OPENING 19/32 EXTERIOR SHEATHING W/PAPERBACKED HI RIB METAL LATH 2X4 PT BLOCKS ALONG ARCH NAIL TO PLYWD. EACH END VIEW W/(3) 10d x 1-1/2" colL NAILS PROJECT LOG ISSUED FOR START 03-30-18 ISSUED FOR PERMIT 05-08-18Lj ui a M ui a W ? z LL a � W � z o Z J � v � U % o a �o Z 0 acn c ego 0 c C O ca d� T � U ai W O- O c au vi o rp c 0 O a� w E o (�i E E o 2 o 0 a)� 0-O U � V (^� 6ti Vey U CCI 0 O w � o ss r � � o ryry N 21 Im s 3 A5 20 � V � U � � o � ^,w 0 w LJ Ln a w O 1/4" = 1'-0" U.N.O. STRUCTURAL PLAN �y AW 56 PROJECT LOG NOTE: THIS TYPICAL DETAIL TO BE USED WHERE CONDITIONS ISSUED FOR START 03-30-18 a: EDGE STRIP DEFINED AS THE LESSER OF 10% 2 ISSUED FOR PERMIT 05-08-18 OF LEAST HORIZONTAL DI OF BUILDING MAY OCCUR BASED ON TRUSS DESIGN AND FIELD CONDITIONS OR 40% OF HEIGHT H BUT ANiOT LESS THAN 4% OF qTRAP LEAST HORIZONTAL DIMENSION OF BUILDING AND AT LEAST 3 FT.------- it 2 ` \ \Oi/ it 1212 `�`\ rr I I rr I TYP. RIDGE CAP & 111 I I ROOF MEMBRANE _L---° - 1\ I ` \l 2x RIDGE BOARD I--------� �`� I (2) SIMPSON H10 CLIPS O I 2 ON 1 SIDE OF TRUSS r--------- I I STAGG. & ATTACHED TO �------------------ - I / 2x6 CATS 0 24" O/C BETWEEN TRUSS RUN 1) ALLOWABLE LOADS ARE BASED ON USP CATALOG 2015-16. 2) BLDR MAY USE LONGER STRAPS OF SAME TYPE SPECIFIED, 3) USE GALVANIZED NAILS OR WOOD 1 ,/ / IAll. I SCREWS AS SPECIFIED BY MANUFACTURER. 4) TAPCONS SHOO BE LOCATED AT THE FARTHEST POINT FROM THE TOP OF THE BEAM, I IPRE ENGINEERED ROOF RING -SHANK NAILS TO HAVE THE FOLLOWING DIMENSIONS: --------- BUSSES SEE FRAMING PLAN 1. 0.113 INCH NOMINAL SHANK DIAMETER NOTE: SEE DIAPHRAGM 2 2 i�' , O\` \\ i 3 ROOF NAILING IS IDENTICAL FOR ZONES 1 8C Z 2. RING DIAMETER OF 0.012 J. 16 TO 20 RINGS PER INCH R SHANK DIAMETER SCHEDULE FOR ROOF Y 2 ` 4. 0.260 INCH FULL ROUND HEAD DIAMETER ZONE NAILING -1 ---� --- i-I 5. 2 INCH NAIL LENGTH REQUIREMENTS. FIELD FRAMED RIDGE DETAIL ROOF ZONE DIAGRAM M O � O O W V N 1 r N O J J H rn W y n a ? z w w LL w w K U 39# MAX. UPLIFT.i z J U J V J v m rn TC-1 7 llyr g �G Z c M L) M JQ G,\ M M Oco Lo tx a M N tl' JQ�iG \ �y✓, U U U U �� (i i 39 MAX. U LIFT TC-1 M } CJ1 o 0 6 —° > �CJ1 gP � J1 o fl. ,Z— a o 0 0 X¢ H O •in �CJ3 J3 EJ2 a +� °�' w 26 �' -CJ1 r7 E .`f o co •w >< > EJ °� _ .� ro zi -CJ5 I G. a O R u KRE U RED ® -CJ3 -EJ7CL 10' - L 0 G. 9' CLG c� ,Z o �EJ4 E= aoi o C5 c a a) E E o 6 0 K xo S E v O -p o c� -EJ7 "o U �EJ4 E a) a) U) a) o- = is s a) > a) CD c) E OD CE v, a ox > / = -EJ7 ODD P E -EJ4 E a = EJ7 56 # X.� - -EJ4 z fl a O EJ7 C- M K x_ o C:) 9' -4" CL> >< G U U� -EJ4 x K X' -EJ7 0 EJ4 EJ7�x >< �EJ4 _ E 11 >< > in L� q� U �CJ5�x q1 Zu.) g ® MV6 �L 9' - 'CLG. -CJ3 E coV24KK MV4 ® O A/C O m O -CJ1 > xMV 0 -EJ7 9' - " CL O a Ne LZ \IKI A/C �-, L u ca CD 9r of -EJ7B a E tCt> g44-EJ7AY�t JQv -EJ7A n N P. 9' -4" CLG. N N 9' CLG. DRY R VE T -EJ7A V O D SP CE --CJ5B a a -CJ3A OD %P E OD SPA E OD SPA E GABLE END OVERHANG OD S ACE 9' CLG O D SP CE " -CJ1 Y� I M In iD �"' � _ (� _ � (D � N N N N M cy) cl) M M M M M co Lu .r M M O O O O O O O O � N N N co O O O O O O O O O O O O O O [�] J U U U O Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q N CO m m m m Ib CO m m m m m m m I""'I 2 I Q Q Q 0 �7 LL_ F` b JQ� w w /^ z F�1 . U o U v 39# MAX. UPLIF 725# MAX. UPUFT E.E. 720# MAX. UPLIFT E.E. 474# MAX. UPLIFT E.E. ,W_, TC-1 i TC-1 o TC-1 N TC-1 yy U lil_ iwo) NUOf— H co H F-- F H �/ I J W OJ � L~ 1/4" = V-0" U.N.O. 9'-4" PLATE HT. HARDWARE: TRUSS =HUS26 HANGERS (QTY. 2) PLAN A-6 10' -8" PLATE HT. Indicates Left End Of Truss On Layout & Engineering Sheets Nlw = 56 TRUSS CONNECTOR SCHEDULE FASTENERS PER ALLOWABLE UPLIFT PARALLEL LOAD (F2) PERPEND. LOAD (F1) MARK USP CONNECTOR TRUSS TIE -BEAM OR WALL SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP TC-i TA12 (5) 10d x 1-1/2' - 990 9980 335 670 245 490 TC-2 TA14 (7) fOd x 1-1/2" - 1205 2410 335 670 245 � 490 TC-3 HTWMi6 8 fOd x 1-f 2' 4 1 4" x 1-3 4' WAB. 1225 - 1225 - 1225 - TC-4 HTA16 9) 10d x 1-1 2" - 1870 2430 710 13f0 270 1215 TC-5 HTWZO 20 fOd x i-1 2 24 10d x 1-1 2" 1530 - - - - - DIAPHRAGM SCHEDULE (FASTENING REQUIREMENTS PER R803.2.3.1) DIAPHRAGM NAILING DIAPHRAGM ZONE 1 ZONE 2 ZONE 3 PANEL FRAMING BOUNDARIES EDGE INTER. EDGE INTER. EDGE INTER. LOCATION PANEL GRADE THICKNESS SPACING REMARKS ROOF APA RATED SHEATHING 8d RING- 8d RING- 8d RING- 8d RING- 8d RING- 8d RING- 8d RING - EXPOSURE 1, OR EQUAL 24" 0/C SHANK SHANK SHANK SHANK SHANK SHANK SHANK BLOCKED AS SPAN RATING 40 20 19 32° MAX. 6" 0 C 6" 0 C 6" 0 C 6" p C 6" 0 C 4" 0 C 4" 0 C SHOWN ON PLAN EXT. WALL APA RATED SHEATHING EXPOSURE 1, OR EQUAL SPAN RATING 40 20 19/32 16" 0/C MAX. 8d RING- SHANK 4" 0 C 8d RING- SHANK 4" 0 C 8d RING- SHANK 6" 0 C NAIL CORNER STUDS AT 4" 0/C MAX. TYPICAL BLOCK FREE EDGES APA RATED SHEATHING 8d RING- 8d RING- 8d RING- INT. WALL EXPOSURE 1, OR EQUAL SPAN RATING 32 16 15/32 i6" 0/C MAX. SHANK 6' 0 C SHANK 6" 0 C SHANK 12" 0 C BLOCK FREE EDGES PROJECT LOG ISSUED FOR START 03-30-18 ISSUED FOR PERMIT 05-08-18 ELEC. PANEL "UNIT A" 200 AMP CIRC, DESCRIPTION POLE BRKR WIRE VA, 100% 1 AHU HEAT STRIP 2 60 6 0 9.6 1 A/C COMPRESSOR 2 40 8 0 0 1 COOKTOP 2 50 6 10.0 0 1 DBL (OVEN 2 50 6 10.0 0 1 DRYER 2 30 1 10 5.0 0 1 WATER HEATER 2 25 10 4.5 0 1 WASHER 1 20 12 1.5 0 1 MICROWAVE 20 12 1.5 0 I DISHWASHER 20 12 1.2 0 1 REFRIGERATOR 20 12 1.2 0 3 SMALL APPLIANCE r 20 12 4.5 01 BATH GFI 20 12r1.5 0 8 GEN. LIGHTING 15 14 0 1 4 /.7 1 9.6 1 1st 10,000 at 100% = 10.00 REMAINDER AT 40% = 15.08 A/C LOAD AT 65% = 6.24 TOTAL = 31.32 x 1000/240 = 130.5 AMPS `�OV. PATIO WP GFI \ SD MASTER SUitL .1 / \ i i / \ I USB STATION 0 COUNTER a (1) SETS OF (3) J410 AWG. THWN IN 2" CONDUIT 200 AMP SERVICE p METER DISC. COMBO PANEL 200 A 5/8" GDX 10' CU SUPPLEMENTAL GROUND ROD AND TO ONE REINFORCEING BAR IN THE FOUNDATION 20'-0" LONG MIN. ELECTRICAL RISER DIAGRAM i - - KITCHEN`; NING -----� DISP. AIR SWITCH b -n — — ;I F _ GFz u u (3) PENDANTS —.._.._.._.._.._.._.._...,..... GREA ROOM - - - I FLOOR OUTLET W/ BRASS COVER CALCULATION NOTES: A. HEAT STRIP LOAD GOVERNS OVER CONDENSER UNIT LOAD. B. GENERAL LIGHTING CALCULATED 0 1,832 (SQ.FT.) x 3 (WATTS/SQ.FT.) = 5,496 / 8 (GEN.LTG.CIR.) = 687 (WATTS/EA.) C. A/C CONTRACTOR SHALL SIZE A/C UNITS. A/C UNITS SHOWN ARE FOR ELEC. CALC'S. ONLY. NOTE: PROVIDE ARC —FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL RECEPTACLE AND LIGHTING OUTLETS INCLUDING SMOKE DETECTORS PER 2017 NEC 210-12 (B). NOTE: GARAGE PUSH BUTTON LOCATED 0 60" ABV GARAGE FLOOR 72" MAX. NOTE: ALL EDGE OF SWITCH PLATES TO BE NO LESS THAN 4" FROM OPENINGS NOTE: ALL VANITY WALL LIGHTS TO BE 100" A.F.F. U.N.O. POWDER ROOM TO BE 86" A.F.F. IF APPLICABLE Plans are Prepared for the Builder and not any Planned or Future user / Home owner of the Subject Property and any Modifications, Deletions and other Changes Authorized by GHO Homes Corporation or other GHO entity are Permissible to included, but not be limited to Electrical Design Modification, Fixture or Outlet or Circuit changed, Combinations or Changes. All Final Work shall be at a minimum Equal to Code minimums and any changes are only Permissible if Suggested and complete by a licensed Electrician so long as Applicable Codes are Met and Load Sufficient to Meet GHO's minimum Level of Service and Operation. NOTE: ACCEPTABLE SMOKE & CARBON DETECTORS TO BE INSTALLED ARE BRK SMOKE-9120B C/O—SC9120B KIDDE SMOKE-21007581 C/O 21006377—N II i II i / \ SD PORCH DOORBELL`\ FOYER I I -' ---- - i i FIB ;It ls \ TH 2 LI' I' �xL I I FLUOR. UTILITY I ......................... _..�.._ r--�r�-� I� �I'L�JI •i I \'... I I BATH ' L _ _J ,. / ---- ® TWO BAY GARAGE j MASTER / I I I i ,KDR00k1 C , I ELECT. & CHASE 0 FRAME -OUT SEE DTL SHEET A-2 IRRIGATION PUMP & TIMER 11JW w d0 W o N W " w LL J _J W zLL ^ LL e w m LL W z z Z Q K U 0 a h Z 0 0 LL 0 0 0 Lf,"7 4 m 0 U i Cr En C � PHOTO CELL TIMalm; LU COSENSOR IN U)CSOFFITag U o J d! = N To via I + �� 4 C'� V W I� —J LL A a Z O UU w 0 W rh 0 U Z:) `./ ' _J O W U 1/4" = 1'-0" U.N.O. ELECTRICAL PLAN E W=56 PROJECT LOG ISSUED FOR START 03-30-18 ISSUED FOR PERMIT 05-08-18 2" KITCHEN AVV KIT CO OW 2" 2" AVV 2. LAV LAV CO 3° 2" 2" VTR Wp J 2" SHWR MASTER BATH \ \ \ 3" 2, \ TUB \ \ 3, LAV \ CO 2" W a LT o 3" CO o W v Wp u�i # _j M 3" BATH 2 pp A 3" w ?WM 3" a Z W z U 3" LAUNDRY J PLUMBING RISER DIAGRAM z 0 O a HB - ---—--------------------- - n — 155CFM ��u 1-�cu ® ------ O O ----- ------ 1 a x +0 x a a m a� o 0 1�x1®xC o KITCHEN 110CFM ® �® = DINING U Q 1§ S L 70 E o 1®X10xa DEN 561 CFM � 42,.xga„ o aj o Q ai E E Q 0o 0 2 U 0 ® W/ 8110 8110 a 5 � � � a ® 8„0 FLEX ® o �' o ", o ® ® PORCH ® o oLn � _N(D N OJ COV. PATIO 12"0 ' 5"0 FOYER 8110 AHU-(, 6 x 6 x 5 3-TON 32 CFM GREAT ROOM 0 ® ® Z 10x 1Gx8 .: O 190 CFM v 0Ini 10"0 9„0 ® ® ®® 1 F- E B x 5 x 5 45 CFM cis �0 R UTILITY E ® 8„� � d„/ c O ® ® ® B H 2 4,. R.A.® m 22 x22 I 4 0 DRYER TWO BAY GARAGE � u ® o 0 6 x 6 x 4 W/ 1 o EXHAUST U U ® 1, CFM FLEX a j c _ --- > W H C J ®----------------- --------- O O x , z u� ® u o xo - 4, 2"x, 2„ I NLo N 3 = C�i 1,0x 10 x 8 R *$ xt 6 8„o 4„0 I R.A.G. a Lu (73CFM ❑A W/A 0 FLEX 8 o BEDROOM 2 ® Q 04 FLEX 4"0 9X8x5 50 CFM 83 CFM 8 4 EXHAUST®�F I MI GOLF CART ® ZC r� � 6x�ax MASTER SUITE 2(CFM WIC T IEx 50 �F�� 1®xt®x6 cs Li160 �FM Z u-. 11 V 8H 3-TON NOTE: u W U ALL RETURNS SHALL HAVE DIRECT DUCTING E' TO RETURN AIR PLENUM BOX. f D® NOT SCALE PLANS n A a z u- U o 0 w 0 w 1.0 Ln Q J W ( 1/4" = P-0" U.N.O. MECHANICAL PLAN M-1 MW = 56