HomeMy WebLinkAboutEVALUATION REPORTF)o RECEIVED EXTERIOR RESEARCH StDESIGN, I.I.C. Certificate of Authorization 49503 T� HERD JUL 06'I..IJ19 353CHRISTIANSTREET,UNIT#13 OXFORD, CT 06478 ST. Lucie County, Permitting (203) 262-9245 EVALUATIO 'REPORT Polyglass US, i, Inc. Evaluation Report P12060.02.09-1123 150 Lyon Dri JIe SCANNED FL5259-R27 Fernley, NV S8408 BY Date of Issuance: 02/24/2009 (570) 384-12till Revision 23: 09/14/2017 SCOPE: This EvaluatioQn Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction "jnaterials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of tlje product under the Florida Building Code and Florida Building Code, Residential Volume. The products described h ein have been evaluated for compliance with the 6 Edition �2017 Flori a Bui in Coe ections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: La eling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Rtality ort by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to ul dated Code requirements with each Code Cycle. ADVERTISEME The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising Ii erature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors 4d shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared Robert J.M. Nieminen, P.E. Florida Regisd,al tion No. 59166, Florida DC4ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/14/2017. This does not serve as an electronically signed document. . CERTIFICATION OF INDEPENDENCE: I' 1. Trinity ER does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributirIIg products it evaluates. 2. Trinity) E D is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Ni'I minen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which th evaluation reports are being issued. 4. Robert Ni aminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. /0) 61�' j LUCIE COUNTY BUI DIVISION IEWED FOR COMPLIAM @ C It FILE COP Y S AND'PEftMIT"MUV811 KEPT ON JOB OR NO INSPECTIONS) WILL BE MADE ROOFING COMPONENT EVALUATION: 1. SCOPEj 2. STAN 3. `J TRINITY ERD Category: Roofing ?gory: Underlayment nce Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the sections of the Sth Edition (2014) Florida Building Code through testing in accordance with the following Standards. nce is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3 � Wind Uplift FM 4474 2011 1504.31 Wind Uplift UL 1897 2012 1507.2 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2 4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.33 Physical Properties FRSA/TRI April 2012 2012 1507.1 .2 Physical Properties ASTM D6164 2011 1507.1 .2 Physical Properties ASTM D6222 2011 1523.6 5.2.1 Physical Properties TAS 103 1995 TAS 11 Accelerated Weathering TAS 110 2000 REFER I LACES: Entity Examination Reference Date FM Ap rovals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TS 5878) Physical Properties PRI01111 04/08/2002 PRI (TS 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TS 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TS 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (T51 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TS 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TS 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TSY PRI (T 5878) 5878) Physical Properties Physical Properties PUSA-061-02-02 PUSA-076-02-01 01/28/2008 02/22/2008 PRI (T 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (T 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (T T 2508) Physical Properties JX20H7A 04/01/2008 MTI (T T 2508) Physical Properties RX14E8A 01/29/2009 ERD (T iT 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (T, T 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (T T 6049) Physical Properties 02200.07.03 07/14/2003 ERD (T T 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (T T 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (T(, 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (T T 6049) Physical Properties P13450.08.09 08/13/2009 ERD (T T 6049) Wind Uplift P30540.11.09-R3 11/30/2009 ERD (T T 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (T,�T 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (T T 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD (T T 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TT 6049) Physical Properties P37300.10.11 10/19/2011 Exterior Re.,IeIarch and Design, U.C. Evaluation Report P12060.02.09-R23 Certificate ofbutharization 49503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 2 of 14 Entity ERD (TS ERD (TS ERD (TS ERD (TS ERD (T ERD (T ERD (T ERD (T ERD (T ERD (T ERD (T ERD (T ERD (TS ERD (TS ERD (TS ERD (TAS ERD (TS ERD (T$ ERD (T� ERD (T� ERD (T ERD (T ERD (T ERD (T ERD (T ERD (TS ERD (T ERD (T ERD (T� [CC -ES 11 UL, r 6049) r6049) r 6049) r 6049) r 6049) r6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r 6049) r6049) r 6049) r6049) r6049) :VL 2396) lade (CER 1592) s USA s USA s USA (QUA9625) 4. PRODOcr DESCRIPTION: Examination Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physical Properties Physical Properties IBC Compliance HVHZ Compliance Manufacturing Affidavit PA Affidavit Materials Affidavit Quality Control Reference P40390.08.12-1 P40390.08.12-2 C41420.09.12-3 P39680.03.13 P45370.04.13 P1738.02.07-R2 11757.04.01-1-R1 P41630.08.13 P11751.05.03-R1 P11781.11.03-R1 P45270.05.14 6020.07.14-1 6020.09.14-2 6020.09.14-3 6020.09.14-4 6020.09.14-5 6020.09.14-6 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC7550.03.15 P40390.04.15 PLYG-SC8080.05.15-1 PLYG-SC8905.05.16-1 PLYG-SC8080.07.16 PLYG-SC12025.10.16 PLYG-SC13040.12.16 PLYG-SC11900.03.17 PLYG-SC12115.08.17 ESR-1697 NCIA 14-0717.08 Products Current Mule -Hide Cross Ltg Polystick SA Compound Service Confirmation 41 • • I Mechanically fastened-Underlayme.nts: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. \l TRINIIYIERD Date 08/06/2012 08/07/2012 09/11/2012 03/04/2013 04/26/2013 04/29/2013 04/30/2013 08/06/2013 11/26/2013 11/26/2013 05/12/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 10/03/2014 10/07/2014 10/17/2014 03/24/2015 04/03/2015 05/20/2015 05/17/2016 07/16/2016 10/12/2016 12/27/2016 03/10/2017 08/08/2017 11/01/2014 01/22/2015 02/18/2009 03/01/2008 08/18/2011 Exp.10/05/2018 I4.2 �l "Self-AdheringUnderlayments: 4.2.1 . Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets TAS 103. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Pol stick TU Plus s a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. Exterior Re b arch and Design, I.I.C. Evaluation Report P12060.02.09-1123 Certificate of uthorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 3 of 14 4.2.4 4.2.5 4.2.6 4.2.7 4.2.8 4.2.9 TRINITY I ERD Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and TAS 103. Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. Polystick Dual Pro'' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. Polystick Tile Pro'"' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4 3 Mechanically'Fastened and/or Bonded Underlayments: 4.3.1 4.3.2 4.3.3 5. Limn 5.1 5.2 5.3 5.4 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. This Evaluation Report is not for use in the HVHZ. Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. Exterior Res arch and Design, I.I.C. Evaluation Report P12060.02.09-R23 Certificate of utharizotion #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 4 of 14 5.5 Allowable Roof Covers: \I TRINITY I ERD Underla ment Asphalt Shingles Nail -On Tile Foam -On Tile Metal wood Shakes & Shingles Slate Elastob Se Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Elastob 5e P Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes " Yes Yes Polyglas I G2 Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No Polyglas APP Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No PolysticdMTS Yes Yes No Yes Yes Yes Polystic„ IR-Xe Yes No No No Yes Yes Polystic TU P Yes Yes Yes (See 5.5.1) No Yes Yes Polyst)c�-TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystic TU Max No Yes Yes (See 5.5.1) Yes No No Polystic Dual Pro Yes No No Yes Yes Yes Polystic Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystic MU-X Yes. --No No Yes Yes Yes Elastofl 56 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastofl S6 G FR Yes Yes No No Yes Yes Elastofl G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes —Polyfle),p FR Yes Yes No No Yes Yes Polyfle AP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule-H or SA -A de SA-APP Cap Sheet 1,P Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. II TABLE'1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Underlayments Approval DAP F am Touch `n Seal StormBond Roof Tile Ad esive FL14506 Polystick TU Plus, Polystick TU Max Dow TileBondTM FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Ad esives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Ad esives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polyg[Os PolyLok Roof Tile Adhesive FL17855 Polystick TU Plus or Polystick TU Max 1 Refer to 7,Iyle Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Res�arch and Design, I.I.C. Evaluation Report P12060.02.09-1123 CertI of uthorization #9503 67X EDITION (2017) FBC NON-HVHZ EVALUATION FL5251 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 5 of 14 5.6 5.6.1 5.6.2 5.6.3 (_)o V I RINITY I ERD Allowable Substrates: Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM 641 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. Exterior Re�'I'arch and Design, I.I.C. Evaluation Report P12060.02.09-R23 Certificate of��U '(thorization #9503 a EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017 Page 6 of 14 F)o TRINITY I ERA 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure = -97.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y4" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -135 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #5 Maximum Design Pressure = -315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex.SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #6 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #7 Maximum Design Pressure = -30.0 psf*: Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: it ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #8 Maximum Design Pressure = -37.5 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. Exterior Re arch and Design, I.I.C. Evaluation Report P12060.02.09-R23 Certificate afAuthorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1127 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 7 of 14 TRINITY ERD #9 Maximum Design Pressure = -37.5 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #10 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt. #11 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #12 Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #13 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four 4 equally spaced staggered center rows. P () q Y P gg Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #15 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #16 Maximum Design Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three 3 equally spaced staggered center rows. g P () q Y P gg Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Exterior Research and Design, I.I.C. Certifcate of uthorizotion #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments; (570) 384-1230 Evaluation Report P12060.02.09-R23 FL5259-R27 Revision 23: 09/14/2017 Page 8 of 14 #17 #18 #19 #20 #21 #22 #23 �I TRINITY I ERD Maximum Design Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: CMG #12 Standard Roofgrip with CMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Maximum Design Pressure = -67.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. Maximum Design Pressure = -75 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Maximum Design Pressure = -90 Dst Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with CMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. Exterior Re earch and Design, I.I.C. Evaluation Report P12060.02.09-R23 Certificate of 1 uthorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017 Page 9 of 14 TRINITY ERD #24 Maximum Design Pressure = -97.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #25 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #26 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #27 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 5.6.4.3 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MLI-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. Exterior RedIearch and Design, U.C. Evaluation Report P12060.02.09-R23 Certificate ojAuthorizotion #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 10 of 14 6. 5.9 V I KINITYIERD Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. I TABLE,2: TILE SLIPPAGE LIMITATIONS FOR'DIRECr-DECK.TILE INSTALLATIONS Underl iyment Tile Profile Staging Method Maximum Slope Elastofl G TU Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastofl S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystic MTS Flat or Lugged Prohibited without battens N/A PolysticR Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystic TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystic TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystic c TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyfle G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyfle JSA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6 3 " Elastobase .E ,lastobase P or Mule -Hide Nail Base ' • 6.3.1 6.3.2 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (0412) Installation Manual. Exterior Res arch and Design, I.I.C. Evaluation Report P12060.02.09-R23 CertiFcate ofLhorizotion #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 11 of 14 \I TRINITY (ERD 6.4 Polystick MTS, IR-Xe, TU P, TU Plus, TU Max; Dual Pro, Tile Pro or MU-X or Polyflex SAP, Polyflex SAP FR, Mule -Hide }, SA-APP Cap•Sheet or Mule -Hide SA-APP Cap Sheet (FR); 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. 6.4.3 6.4.4 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. Tile Applications (not allowed for Polystick Dual Pro, IR-Xe or Polystick MU X): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. Two (2) Ply Underlayment Systems: Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Exterior R&Tarch and Design, U.C. Evaluation Report P12060.02.09-R23 Certificate or uthorization u9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 12 of 14 J 6:S . , ElastofleX:G TU, Elastoflex S6 G or Elastoflex S6 G FIR: ; F"Ilcll �,l I RINITY I ERD 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt . applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FIR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6 6 I(. , Polyflex G or Polyflex GFR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-22) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3). ✓ Polyflex G FIR is for use as an alternate to the Heat Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). 6.6.2 Polyflex G or Polyflex G FIR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6_7 Tile Stasini;: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail - boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1123 Certificate of t thanzation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017 Page 13 of 14 TRINITY I ERD 7. BUILDI I G PERMIT REQUIREMENTS: As req fired by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUIIIIACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants ;iave qualified products under their respective physical properties specifications. 9. Plant Specification ` ' ;, 'Products"..' Fernle , NV, Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick MU-X Hazlet'; n, PA M-D 13-0004 Elastoflex G TU Hazlet) n, PA & Winter Haven, FL ASTM D1970 Polystick IR-Xe ASTM D1970 & TAS 103 Polystick TU Plus ASTM D1970 & TAS 103 Polystick TU Max Tuscaloosa, AL ASTM D4601, Type II Polyglass G2 Base Winte � Haven, FL ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base TAS 103 Polystick MTS ASTM D1970 & TAS 103 Polystick TU P FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970 & TAS 103 Polystick Tile Pro ASTM D6164 Elastoflex S6, Elastoflex S6 G FR ASTM D6222 Polyflex G, Polyflex G FR U L, N ASSURANCE ENTITY: —QUA9625; (314) 578-3406; k.chancellor@us.ul.com Exterior Research and Design, I.I.C. Certificate of4juthorization #9503 - END OF EVALUATION REPORT - Evaluation Report P12060.02.09-R23 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 14 of 14 JUL 0 6 2010 MIAMI•DADE LST.ucie county,.'.._r..1 f_ �! MIAMI-DADE COUNTY ----===— PRODUCT CONTROL SECTION DEPAR NT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTI E OF ACCEPTANCE (NOA) www.�amiaaae.gov/economy Metal ales Manufacturing Corporation 545 Sotith 3rd Street, Suite 200 Louisville, KY. 40202 SCOP This N A is being issued under the applicable rules and regulations governing the use of construction materials. The docurn tation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in ami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This N �A shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miattu Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or mateal tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufa turer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such roduct or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is detetmi ed by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This pnduct is approved as described herein, and has been designed to comply with the Florida Building Code includir g the High Velocity Hurricane Zone of the Florida Building Code. : 5V Crimp Metal Roofing System JG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENE,VAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. '11RMi ATION of this NOA will occur after the expiration date or if there has been a revision or change in the materia s, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, a' vertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. TISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the i date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall b Iavailable for inspection at the job site at the request of the Building Official. This rei I lews and revises NOA#13-0627.02 and consists of pages 1 through 9. The su mitted documentation was reviewed by Freddy Semino IN NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 1 of 9 5V-C Roof Trim 1 Akzo Valsl Unde PRI ( iG SYSTEM APPROVAL: _ Roofing ;Eory: Metal, Panels (Non -Structural) Steel )e• Wood n Design Pressure-196.75 psf. NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product oduct Dimensions Specifications Description Metal 1= varies TAS 110 Corrosion resistant, galvanized, preformed, w = 24" coated, prefinished, metal panels. h = V2" Min. Thickness 0.0179" (26ga.) Min. Yield Strength: 60ksi ;es 1= varies TAS 110 Standard flashing and trim pieces. w = varies Manufactured for each panel width. Min. Thickness 0.0179" (26ga.) 'ACTURING LOCATION: ksonville, FL. 14CE SUBMITTED: Test Agencv Test Identifier Test Name/Report Date iters Laboratory struction Materials Corporation Testing e Test Laboratory, Inc. ;h Engineering and Inc. R9697 MSMC-003-02-01 MTS 520103 0103-0712-09 T240-09 ASTM G 23 ASTM B 117 ASTM G 23 ASTM B 117 UL 790 TAS-100 ASTM E 8 TAS 125 TAS 125 October 2016 June 2006 Jan. 1999 Sept2009 Sept 2009 NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 2 of 9 ASSEMBLIES: System : 5V-Crimp Metal Roof Panel Deck T e: Wood, Non -insulated Deck D cription: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. Maxim m Uplift See Table A below. Deck A achment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") the above attachment method must be in addition to existing attachment. Underl yment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side - lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 '/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Ba' rier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. ValleysValley construction shall be in compliance with Roofing Application Standard RAS 133 and with Metal Sales Manufacturing Corporation's current published installation instructions. Metal Panels and Install the "5V-Crimp Panels" and accessories in compliance with Metal Sales Manufacturing Accessories: Corporation's current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Panel fasteners shall be #9-15 x 1 '/2" self drilling, self tapping, hex head screws with sealing washer of sufficient length to penetrate through the sheathing a minimum of 3/16 inch. Fasteners shall be installed at a maximum spacing as listed in Table A below parallel to the slope. Fasteners shall be installed at a maximum of 12" o.c. at panel edge. See detail herein. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corners Maxim' m Design Pressures -74.8 psf. -196.75 psf. Maximum Fastener Spacing 16" o.c. 8" o.c. 1. Extras olation shall not be allowed NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 3 of 9 1 System 9: SV Crimp Metal Roof Panel Deck T I, e: Wood, Non -insulated Deck Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. Maximi4m Uplift See Table B below. Deck A chment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32"` the above attachment method must be in addition to existing attachment. Underl yment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side - lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Ba' rier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Metal Sales Manufacturing Corporation's current published installation instructions. Metal anels and Install the "5V-Crimp Panels" and accessories in compliance with Metal Sales Manufacturing Access fries: Corporation's current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Panel fasteners shall be #9-15 x 1%" self drilling, self tapping, hex head screws with sealing washer of sufficient length to penetrate through the sheathing a minimum of 3/16 inch. Fasteners shall be installed at a maximum spacing as listed in Table B below parallel to the slope. Fasteners shall be installed at a maximum of 6" o.c. at panel edge. See detail herein. TABLE B MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maxii0m Design Pressures -84.5 psf, -131.3 pst Maxiffi, m Fastener S acin 24" o.c. 18" o.c. 1. Extra olation shall not be allowed NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 4 of 9 LIMITATIONS TIONS 1. Fi a classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ra I" ngs of this product. 2. T I e maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, a corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced p ssure zones (i.e. perimeters, extended corners and corners). 3. P I el shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in the R ofmg Application Standard RAS 133. 4. A 1 panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: Xiami-Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen ,w. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. 5. 111, products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and le 61 G20-3 of the Florida Administrative Code. NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 5 of 9 PROFILE DRAWINGS DETAIL A 5V-CRIMP METAL ROOF PANEL 24" Coverage #9-15 x 1 1/2" Woodgrip Screw #9-15 x 1 1/2" Woodgrip Screw 5V-Crimp Panel ` Moisture Barrier Plywood Decking (By others) (By others) ASTENING PATTERN FOR 5V-CRIMP AT INTERIOR OF PANEL 24" Coverage #9-15 x 1 1/2" Woodgrip Screw ,--5V-Crimp Panel \-Moisture Barrier Plywood Decking (By others) (By others) FASTENING PATTERN FOR 5V-CRIMP AT EAVE NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 6 of 9 5V-CRIMP METAL ROOF PANEL SeeTable A Herein for Maximum Fastening Spacing 5V Panel NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 7 of 9 I DETAIL B 24" Coverage #9-15 x 1 1/2" Woodgrip Screw #9-15 x 1 1/2" Woodgrip /-5V-Crimp Panel \_Moisture Barrier Plywood Decking (By others) (By others) FASTENING PATTERN FOR 5V-CRIMP AT INTERIOR OF PANEL 24" Coverage #9-15 x 1 1/2" Woodgrip Screw , 5V-Crimp Panel \_Moisture Barrier Plywood Decking (By others) (By others) FASTENING PATTERN FOR 5V-CRIMP AT EAVE NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 8 of 9 SeeTable B Herein for Maximum Fastening Spacing END OF THIS ACCEPTANCE 5V Panel NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 9 of 9