HomeMy WebLinkAboutNOAti
SCANNED
BY
Lurie COMV THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS MIArvII-DADS COUNTY
IIAMI REQUIRED BY FIELD INSPECTORS THAT PRODUCT CONTROL SECTION
ea _ MAY ppBENECESSARY pINplORDER TO208
DEPA TMENT OF REGULATORY Al �°UliOv11C RES UkCEs( RLE CO�F_S. 11805 SW 26 Street, Room 474
i i R Miami, Florida 33175-2474
BOAR AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NO' ''ICE OF ACCEPTANCE (NOA) wwnv.miamidade.%!ov/economv
Entelra Roof Tile, LLC RECEIVED
1289 ENE 9" Ave
Okeechobee, FL. 34972 J U L 0 6 2018
SCOPE: ST. Lucie County, PorMItting
This IIOA is being issued under the applicablerules and regulations governing the use of construction materials. The
docu entation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used,in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This,POA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in
Mia ' Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
mat -ial tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
man, facturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
sucl � product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is detennined by
Mia ni-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
buil' ine code.
Thig product is approved as described herein, and has been designed to comply with the Florida Building Code including
the I igh Velocity Hurricane ,Zone of the Florida Building Code.
FILE CUFM
D SCRIPTION: Bermuda Concrete Flat Roof Tile 1
1G: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
"Miami -Dade County Product Control Approved", unless otherwise noted herein.
NEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
applicable building code negatively affecting the performance of this product.
RMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
-rials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
s, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
NOA shall be cause for termination and removal of NOA.
DVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
piration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
its entirety.
SPECTION: A copy of this entire NOA shall be provided to the user by the ufactu is d=is utors and sl}all
available for inspection at the job site at the request of the Building Official. 12- �8 d 1 t _ * r
is NOA renews NOA No. 14-1120.06 and consists of pages 1 tluou h 6. ST. LUCIE COUNTY BUILDING VISIO
P g g REVIEWED FOR COMPLIANCE
e submitted documentation was reviewed by Gaspar J Rodriguez. REVIEW,F� BY I ff) ���%%V/%j
;EALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD `.
,M -DADE COUNTY .
MEVNI M"
DATE "
PLANS D E MIT MUST BE KEP ON 308
SITE OR NO INSPECTIONS) WI BE MADE
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page l of 6
`
4
ROOFING ASSEMBLY APPROVAL.
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile,; LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as
determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared
as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
Entegra Flat Tile
Length = 16"
TAS' 112
Flat profile, interlocking, high pressure extruded
Width = 10"
Type'3a
concrete roof tile equipped with two nail holes.
Class III
For mechanical, mortar or adhesive set
applications.
Trim Pieces
1= varies
TAS 112
Accessory trim, concrete roof pieces for use at
w = varies .
hips, takes, ridges and valley terminations.
varying thickness
Manufactured for each tile profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Redland Technologies
7161-03
Static Uplift Testing
Dec. 19911
Appendix III
PA 102 & PA 102(A)
I ��
The Center for Applied Engineering,
94-084
Static Uplift Testing
May 104.
Inc.
PA 101 (Mortar Set)
i
The Center for Applied Engineering,
94-060A
Static Uplift Testing
March, 1994
Inc.
. PA 101 (Adhesive Set)
The Center for Applied Engineering,
25-7094-2
Static Uplift Testing PA 102
Oct. 199
��.
Inc.
(4" Headlap, Nails, Direct Deck, New
Construction)
The Center for Applied Engineering,
25-7094-8
Static Uplift Testing PA 102
Oct. 1994
Inc.
(4". Headlap, Nails, Battens)
The Center for Applied Engineering,
25-7094-5
Static Uplift Testing PA 102
Oct. 1994,1
(4" Headlap, Nails, Direct Deck,
Recover/Reroof)
The Center for Applied Engineering,
25-7183-6
Static Uplift Testing PA 102
Feb. 1991 i
„r
Inc."
(2 Quik-Drive Screws, Direct Deck)
"
MIAMI•DADE COUNTY
�Fg...• •
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/f ,,
Page 2 of I61
IIIli I
2.2 EVIDENCE SUBMITTED
1I Test Agency
The C II ter for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc. I
The C nter for Applied Engineering,
Inc.
Redla%d Technologies
�I
Redland Technologies
Redla� d Technologies
Redl d Technologies
C
I'
The enter for Applied Engineering,
Inc.
Atlanta Testing & Engineering, Inc.
I
Profl ssional Service Industries, Inc.
II
Celotex Corporation Testing Service
Celgtex Corporation Testing Service
Walker Engineering, Inc.
Wai�Cer Engineering, Inc.
Walker Engineering, Inc.
W4ker Engineering, Inc.
W�lker Engineering, Inc.
W 'lker Engineering, Inc.
Welker Engineering, Inc.
Nutting Engineers
American Test Lab of South Florida
Test identifier
25-7183-5
25-7214-1
25-7214-5
7161-03
Appendix H
Letter Dated Aug. 1,
1994
P0631-01
P0402
Project No. 307025
Test #MDC-77
R1.894
R2.894
R3.894
39540011-1
520109-1
520111-4
520191-1
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Calculations
13343.1
RT1210.02-15
Test Name/Report
Date
Static Uplift Testing
Feb. 1995
PA 102
(2 Quik-Drive Screws, Battens)
Static Uplift Testing
March, 1995
PA 102
(1 Quik-Drive Screw, Direct Deck)
Static Uplift Testing
March, 1995
PA 102
(l Quik-Drive Screw, Battens)
Wind Tunnel Testing
Dec. 1991
PA 108 (Nail -On)
Wind Tunnel Testing
Aug. 1994
PA 108 (Nail -On)
Wind Tunnel Testing
July 1994
PA 108 (Mortar Set)
Withdrawal Resistance Testing of screw
Sept. 1993
vs. smooth shank nails
Wind Driven Rain
Oct. 1994
PA 100
Physical Properties
Aug. 1994
PA 112
Physical Properties
Feb 2004
PA 112
Static Uplift Testing
Dec. 1998
PA 101
Static Uplift Testing
March 1999
PA 101
Aerodynamic Multiplier
March 2004
25-7094
Feb 1996
25-7496
April 1996
25-7584
December
25-7804b-8
1996
25-7804-4 & 5
25-7848-6
25-7183
March 1995
Restoring Moment, Ms
March 2004
Two Patty Adhesive Set System
April 1999
TAS 112
05/06/08
TAS 112
12/17/15
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 3 of 6
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control
Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by.the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
i
4. INSTALLATION
4.1 Entegra `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations. "
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight W (lbf)
Length -I (ft)
Width-w (ft)I
Entegra Flat Tile
9.7
1.33
.833
Table 2: Aerodynamic Multipliers - 7. (ft3) l ,
Tile
Profile
2L (ft3)
Batten Application
2L (ft3)
Direct Deck Applicatioi
Entegra Flat Tile
0.189
0.205
1 :'
Table 3: Restoring Moments due to Gravity - Mg (ft-ibf)
Tile
Profile
3":12"
4":12"
5":12"
6":12"
Greater than
7":12" ICI
Entegra Flat Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.53
6.97
6.43
6.86
1 6.29
6.71
6.14
6.54
5.97
6.35
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/i6
Page 4 of 6
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
I'l for Nail -On Systems
Tide
Profile
III
Fastener Type
Direct Deck
(min 15132" plywood)
Direct Deck
(min. 19/32" plywood)
Battens
Entega Flat
2-10d Ring Shank Nails
30.9
38.1
17.2
Tile
1-10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
2-10d Smooth or Screw
Shank Nails
14.0
18.8
7.4
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or Screw
Shank Nail Field Clip)
24.3
24.3.
24.2
1-10d Smooth or Screw
Shank Nail Eave Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
2-10d Ring Shank Nails' 50.3 65.5 48.3
1 16 stallation with a 4" the headlap and fasterners are located a min. of 2Y2" from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Ent ` gra Flat Til
I Adhesive
31.33
2 ee manufactures component approval for installation requirements.
3 flexible Products Company TileBond Average weight per patty 13.9 grams.
M- 2-Component Foam Roof Tile Adhesive AH-160. Average weight per patty 8 grams.
III
Table 6: Attachment Resistance Expressed as a Moment - Mt (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
En egra Flat
3M- 2-Component Foam Roof Tile Adhesive AH-160
118.94
Til
3W 2-Component Foam Roof Tile Adhesive AH-160
40.45
4 Large paddy
placement of 45 grams of 3M"' 2-Component Foam Roof Tile Adhesive AH-160
5 1 Medium paddy placement of 24 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160
NOA No.16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 5 of 6
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
ENTEGRA FLAT TILE LABEL (LOCATED ON UNDERSIDE OF TILE
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to' obtain a building permit.
i,
PROFILE DRAWING
ENTEGRA "FLAT" CONCRETE ROOF TILE
16'
10'
FIELD TILE
i — 16' _I
THICK BUTT TILE
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
NOA No. 16-0112 07
Expiration Date: 06107�2�
Approval Date: 02/25%6
Page 6 of'6
I
-RECEIVED
1]ip►1?E J i 1 L 06 2 0 A
TMENT OF REGULATORY AND ECONdiii6` -- U )
AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE I
Roofing LLC.
rvine Center Drive, Suite 1.00
CA 92618
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
wivw.miamidade.gov/economy
Thistntation
A is being issued under the applicable rules and regulations governing the use of construction materials. The
di ' submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
use �j in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In iami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
pro uct or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if 41 is determined by Miami=Dade County Product Control Section that this product or material fails to meet the
req'
Thirements of the applicable building code.
iproduct is approved as described herein, and has been designed to comply with the Florida Building Code
i ke uding the High Velocity Hurricane Zone of the Florida Building Code.
D SCRIPTION: BORAL TileSeal FILE COFY
L BELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
st ,cement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
EWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
applicable building code negatively affecting the performance of this product.
ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
aerials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
this NOA shall be cause for termination and removal of NOA.
WERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
shall be done in its entirety.
'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
be available for inspection at the job site at the request of the Building Official.
renewes NOA#13-1113.05 and consists of pages 1 through 4.
submitted documentation was reviewed by .Freddy Semirto
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category_ Roofing
Sub -Category: Underlayment
Material: SBS
PRODUCTS DESCRIPTION:
Product
BORAL TileSeal
Dimensions
36" x 36' rolls
36" x 72' rolls
MANUFACTURING LOCATION:
1. Brentwood, NH
EVIDENCE SUBMITTED:
Test Product
Specification Description
TAS 103 SBS self -adhering asphalt sheet material with a
ASTM D 1970 white glass're-enforced polyester surfacing fabric;
for use as an underlayment in sloped roof
assemblies.
Test Agency Test Identifier
Underwriters Laboratories, Inc. R14610
IRT-Arcon, hic. = 02-012
PRI Asphalt Technologies, Inc. NEI-006-02-01
PRI Asphalt Technologies, Inc. NEI-008-02-01
PRI Construction Materials NEI-045-02-01
Technologies, LLC. NEI-053-02-01
NEI-076-02-01
NEI-034-02-02
Test Name/Report
Follow up Service
TAS 103
TAS 103
TAS 114 (H)
ASTM D 4798 & ASTM G 155
ASTM D 4798 & ASTM G 155
TAS 103 / ASTM D4798
ASTM D 1970
Dater
03/28/02
II
02/28/02
04/01 /b2
i
07/30/02
0510110E
02/14/ 11
01/29/1L
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/1'.7
Page 2 of ;4
-1
ASSEMBLIES:
Deck Twe 1: Wood, non -insulated
Deck Description: 15/32" or greater plywood or wood plank
E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Base heet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" head lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
One or more plies of BORAL', TileSeal Underlayment with a minimum 3" head lap and minimum
6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to
obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps
without black selvage area shall be sealed under lap using an SBS modified mastic.
Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to
deck with approved annular ring shank nails and tin caps at a maximum 6" o.c. at the side laps.
No nails or tin caps shall be exposed.
Approved for Approved Adhesive Set Roof Tile Systems, Mechanically Fastened Roof Tile,
Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies.
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 3 of 4
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
Building Code.
3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
applied over a roofing Base/Anchor sheet underlayment.
5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly
to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
8. Tiles shall be stored on battens on roof pitches greater than 6:12".
9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing
BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL
TileSeal'underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami -Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
12. Roll .or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
Ii
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product C7��
ltrol
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed
in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment
shall be applied over the underlayment, and sealed using an SBS modified mastic. '
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code' �nd
Rule 61G20-3 of the Florida Administrative Code. 1.1
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,leity
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Appro ,ed"
or the Miami -Dade County Product Control Seal as shown below ��,I
MIAMI•D OUNTY �I
III
END OF THIS ACCEPTANCE ',,I►
I�
NOA No.: 17-0530I�0
MIAMFDADECOUNTY Expiration Date: 07/31) 8
Approval Date: 07/27/17
Page 4 of� 4