HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFM �
d
ISCANNED
BY`YJ 11 u
-BCIS Home ', Log In [ user Registration i Hot7opics i Submit Surcharge I Stats & Facts Publications FBC Staff (BCIS Site Maps Links Search
l Product Approval
t U$wR public User
P�oducC Approval Menu;> Product or Application Search > AgpiicaUon List > Application Detail
FL # FL17443-R1 -PC--�/
Application Type Revision L �l.l r v
Code Versicjn; 2017�
Application Status Approved ST. LUCIE COUNTY BUILDING DIV REVIEWED FOR CO IANC
REVIEW E ON
`
'Comments DgTE BY
Archived r r
PLANS AND P RMIT MUST BE
SITE OR NO INSPECTION KEPT 70B
;Product Manufacturer 3 A TAYLOR ROOFING (S) WILL
CONCEAN,e$�,�R' ,Mi — D11 A 1 ACi;It4Es�sTS
302 Melton Drive E MADE
ARE THE RESPONSIBILITY OF THE FT PIERCE, FL 34982
CONTRACTOR OR RECORD (772) 466-4040
kyiewhite228@aol.com
Authorized Signature Kyle Taylor
kylewhite228@aol.com
Technical Representative
Add ress%Phone%Email
Quality Assurance Representative.
Address/Phone/Email
`iHF-SE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
'category
MAY BE NECESSARY IN ORDER TO
Roofing COMPLY WITH ALL APPLICABLE CODES.
Subcategory
Metal Roofing
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or ArchitectName;who developed the Locke Bowden FILECOPY
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality.Assurance Contract Expiration Date
01/23/2023
Validated ,By
Zachary R. Priest, P.E.
J Validation Checklist - Hardcopy Received
Certificate of Independence
F4.17443 RI COI FL 17443 3 A Taylor 2017 Code Eval Report w1 h Details
RSSS.pdf
Referenced Standard and Ydar (of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product,Approval Method
Date Submitted
Date Validated.
Date Pending FBC;Approval
Date Approved
of
Method 1 Option D
01/24/2018
02/14/2018
IF 02/17/2018
04/10/2018
FL # Model, Number or Name
17443A 5 V.Crimp'
Llmits; of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant:'N/A
DesioWllressure- +N/A/-129:25
Other:--129:25 @. 6" o.c. -69:25 @16"' o.c. margin of safety
2:;1:with,24" max., coverage Install per manufacturers detail.
Notfor use.in HVHZ.
17443:2 VICTORIAN CRIMP SHINGLE
Llmlts`of Use
Approved for use in HVHZ: No
Approved for�use outside'HVHZ Yes
Impact Resistant: N/A
Design Pressure: +N/AJ-105
Other: 105PSF margih of safety 221., Install per
manufacturer's detalls and in compliance with FBC 2017 6th
ed. •Not�for useln HVHZ.
Description
_.__._._.... ....
_ .:_.._. ._._..;
26GA 1/2" rib height over 15/32" APA plywood i
...... _.
Installation Instructions
FL17443 R1 II FL 17443 1 A Taylor 2017 Code Eval Report
with Details RSSS Qdf
Verified By: Locke Bowden, P,E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RI AE FL 17443 3 A Taylor 2017 Code Eval Report I
with Details RSSS p
Created by Independent Third Party: Yes
26GA 1/2" RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER
CDX/APA 15/32" PLYWOOD
_ -...__ ...................... _.... _...----.._.... __ .
Installation Instructions j
FL17443 R1 11 FL 17443 3 A Taylor 2017 Code Eval Report
with Details RSSS.p&f
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RI AE FL 17443 3 A Taylor 2017 Code Eval Report
with Details RSSS.pdf
Created by Independent Third Party: Yes
tSack next
Contad'Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
T66 State of Ffonda f5 an AA/EE0 employer.,.LgQyright 2002.2013 State of Florida.:: Privaty State,•ment :: Accessibliity. statement :: Refund Statement
Under Florida law,.`email addresses are publiciecords, If you d not wentyour e-mail address released in response to a public -records request, donsend electronic
mall •to this entity: Instead, contact the office by phone or by traditional mall. I(you have any questions, please contact 850.487.1395. 'Pursuant to Section
45527S(1), florid. Statutes; effectige 0
cco6 r,1 2012,'Iicensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
-one;,l'he` smalls provideif•may be -used for offidal communication with the licensee. However email addresses are public record, if you tlo not wish to supply a personal
adiiresg,.please prpvlde [he Department with an;email address Which can be made available to the public. To determine if you area licensee under Chapter
please dick ere.
product Approval Accepts:
M sCra 0
Credit Card
Safe
Corn
FBC
Of
302 Milton Drive
Fort pierce, FL 34962
(772) 466-4040
with Florida Building Code 2017 (61' ed.)
Fiarida Product Approvaf kule # 61G20-3
ant Quality Assurance Pragram3 PRI COMSTW&ION MATERIALS TECHNOLOGY
;ri" thru fastened K",rib at each panel edge and 1 fastener in the center of the panel, 24" net coverage, 26GA ASTM
2 -q; 5K A85,.018, SOksi'min. over min.15/3k thick CDX plywood deck. Corrosion Resistant fastener #9-15 HWH with
ing washers, metakto.wood.conneetions with fastener length to penetrate 5/16" thru substrate. Fasten along the crown
W rib in;the-center, of -panel; and along the lap. First fastener to be within 3" of panel edges. Min. 8Dx2" annular ring shank
spaced'ii" O:C.:rerooiing, with'iess:than 19/32" plywood (min.15/32"), this attachment is to be used in addition to
ting;.attat rnent. Deck slope 2412 or greater and shall be com liant with FBC 2017 6T" ed. Underlayment: See FBC 2017 6TM
Sec. IS077ableA 7.1.1.
"
Design Pressure:
Spacing:
-69.25 PSF
16" O.C.
-129.25 PSF
6" Q.C.
rM A792; G-50,AZ55, .018, 50ksi'Victorian Crimp Shingle over 15/32" CDX/APA Plywood attached to roof trusses.
i Resistant:Fastener#10 x 1".Zinc plated, MTW Pancake Head, installed at 2 per panel into lock seam. Panels applied
exposure; adjacent shingles`inserted into lock, seam of'previous shingle. Deck slope 2,12 or greater and shall be
1 witf. FBC 2617 6T",ed, Undedaymerre'See FBC 2017 6T" ed., See.1507 Table 1507.1.1
*'"Design Pressure:
-105 PSF
A SAFETY MARGIN OF2:1
Reference Data:
Hur `cane Testaaboratory'(TST-1527.)' #0224-0501-06 TAS 125 (UL 580-941)
PRI' onstruction Materials•Technologies (TST-5878) #FAE-023-02-01 UL 580-06/UL 1897-04z
1. U I58Q-94:teststandards are' equivalent,to UL 580-06 test standards.
1897-04 test standards are
test standards.
Underlaymentto be compliance with currenVFlorida Building Code (FBC)2017 0 ed.. see Chart 1507.1.1
Minimum slope .to be compliant with Florida !Building Code 2017 6th ed., and per with Manufacturer's installation reference.
Productsare cornpliant,with State of'Florida.product approval per Rule 61G20-3. Compliance Method: 1-D
Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered
engineers.
Fire classification •is notpart.of'thisacceptance.: Shear diaphragm values are outside this report.
Supportframing;in;tortipliance w/FBC 2017 6'h ed.; Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
This repgrt does not -imply warranty, installation, recommended product use outside of this report.
of Independence:
Bowden,-P.E: does not have, not vrill acquire a financial interest in any company manufacturi%Tf, 11$51puting products
this evaluation. 5�Dnrrhrrr
Bowden, P E; is.notowned; operated, or controlled by any company, manufacturer, or ��� I� IA roslt et uR er this
9
seal No• r r
to
-o �• `'� PEE p : �Z
'., •. FLORA . •
.,����,6.SS,0NP, ```�,
5 vtrjmp
'Fastener--#9-i5 corrosion resistant, w(sealing washers
24" d6veraoe
Fastener:#9 x 15 corrosion resistant with sealing washers
in 'Compliance with 2017 Florida Building Code, Section 1507
Pentheter fastenih9 :'6"o.c.
' " ""' " " ' " Main Field fas�tenlnglZbx,.
Ptlillhel VVidfh:,26?'
Panel Coverage: 24'!max'Imu ' mi
26GAArchitectural Metal RW'Pahel
VICTORIAN CRIMP SH
IR
MINIMUM 2 FASTENERS
AT LOCK SEAM
I CUT 1/2 SHINGLE
ZEATE STAGGERED
ERN
)RIAN-'CRIMP,
SLES'
9"EXPOSURE
Fastener: #10 x I"
Zinc Plated MTW
Pancake Head