Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLES4 11 j� � •- scai�I �o paE J 1 7 ••'Sr+-z ,xspv.. � ..� I � i jy, r � r. r ..-u:'d+•6 f�- 176 C-y ,y1 �f' '�,� j•�, -. y�j}g 6 - 1,r.BY�'o p�r� �+.aV,V 'I.BOWIBU µ•. {a :A� c.;a� .rFw•``, n 1..`�..Is4..� » f '`.. .."..J,,{. f....-'-.r.kc.r,.::::f.'� Lour.:.„sue_.. v...'L it F BCIS dome I Log In i User Registration ; Hot Topics I Submit Surebarge ( Slats & Facts j Publications 1 'Contact us i SCIS Site Map Links ! Search �t{lflfil Product Approval Ind USER; Public User ` Prnnnrt Annrrn al hteMI > Prang? or Fpntkiuon SYIDCh > pnnlicotrnn I ist > Application Detail RECEIVED 2 h, `r' FL # FL7006-R10 j Application Type Revision J U L 9 9 2018 i Code Version 2017 Application Status Approved i ST. Lucie County PermiGziflg I 'Approved by DBPR. Ap couals.-by-DSP-R=shaTf-{re re ratified by the POC and/or the Commission If necessary. FILE COPY Comments I� Archived .i Product Manufacturer IKO Industries, Ltd Address/Phone/Email 40 Hansen Road South Brampton, NON -US L6W 3H4 (708)496-2800 Ext200 rmetz001@tanpabay. rr.com Authorized Signature Robert Metz rmetzOOI@tampabay.rr.com CONCEALED FAST ENERS OB AI i AC! I1PIcrU —IS Technical Representative Bob Metz ARE THE RESPONSIBILITY OF THE Address/Phone/Email REMCO of Pinellas GOi tRACTOR OR RECORD 456 Avila Circle NE Saint Petersburg, FL 33703 (727) 776-5261 rmetzOOI@tampabay.rr.com Quality Assurance Representative Don Shaw Address/Phone/Email IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579.6706 don.shaw@lko.com THESE PLANS AND ALL PROPOSED WORK Category Roofing ARE SUBJECT TO ANY CORRECTIONS Subcategory Asphalt Shingles REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO Compliance Method Certification Mark or Listing COMPLY WITH ALL APPLICABLE CODES. Certification Agency FM Approvals - CER Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year ASTM D3161 modified to 110 mph 2016 ASTM D3462 2010 ASTM D7158 Class H 2O11 ASTM Ei08 2011 Equivalence of Product Standards ' G, Certified By 00 IL / ��u ,rfLPIC'?ls ST. LUCIE COUNTY BUILDING DI' ON — REVIEWED FOR COMPLIANCE REVIEW DATE PLANS A D PERMIT MUST BE K ON JOB SITE OR NO INSPECTIONS) V? L BE MADE I� y IV� l Product Approval Method Method i Option A Date Submitted 10/08/2017 Date Validated 10/30/2017 Date Pending FBC. Approval Date Approved 11/01/2017 FL # Model, Number or Name Description 7006.1 Cambridge, Cambridge HD, Biltmore Laminated architectural fiberglass asphalt shingle and Biltmore HD manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.; Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Deslgn Pressure: N/A Other: Certification Agency Certiflcate FL7006 R10 C CAC Letter - ASTM Q3161 letter - (9-26- 20171 from FM.ndf FL7006 RIO C CAC letter - ASTM D3462 letter - (9-26- 20171.pdf FI 7006 RIO C CAC Lett - ASTM E108 letter - (9-26- 20171.pdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions F1 7006 R10 II IKO-187-02-01 Letter - installation instructions for FBC FL7006ndf Verified. By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.2 Hip and Ridge 12 Cap This Is a 12' x 12' fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured at iKO's Kankakee, IL, Toronto, Ont. and Brampton, Ontario plants. Limits of Use Certification Agency Certificate FL7006 R10 C GAG ASTM D 3462 - Shinale let_te Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Surveillance Audit Location - (6-28-20171.pdf f1-7006 RIO C CAC Letter - ASTM D3161_letter - (9-26- 20171from FM.Ddf FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26- Other: 2017).ndf FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26- 20171.11dF Quality Assurance Contract Expiration Date 22/31/2020 Installation Instructions FL7006 R10 11 Hip and Ridge Cap Shingle installation i'nstnictions.pdf FL7006 RIO 11 iKO-187-02-01 Letter - installation instructions for FBC FL7006.ndf Verified By: Duc T Nguyen PE 6SO34 Created by Independent Third Parry, No Evaluation Reports Created by Independent Third Parry: 7006.3 Leading Edge Plus Asphalt Shingle Starter Strip One piece fiberglass asphalt shingle used as a starter strip at the bottom of a roof system manufactured in Brampton and Hawkesbury, Ontario plants Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Certification Agency Certificate FL7006 RIO C CAC Letter - ASTM D3161 letter - ( 26_ 20171 from FM.pdF FL7006 RIO- C CAC Letter - ASTM D3462 letter - (9-26- Impact Resistant: N/A 20171.11df -_ (9-26- Design Pressure: N/A Dther: FL700b R10 C CAC Letter ASTM F108 letter - 20171.pdf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 Rio ff iKO-187-02-01 Letter - installation Instructions for FBC FL7006 ndf FL7006 RIO 11 Roofing -Products -Leading Fdne-Plus- Application-FN(11.pdf Verified By: Duc T Nguyen PE 65034 Created by Independent Third Parry: No Evaluation Reports Created by Independent Third Party: 7006.4 Marathon Plus AR, Superglass Plus 3 tab fiberglass asphalt shingle manufactured at iKUS AR Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.; Sylacauga, AL and Kanakakee,IL plants .y i `e Limits of Use Approved for use in HVH2: Yes Approved for use outside HVH2: Yes Impact Resistant: N/A Design Pressure: N/A Other: Certification Agency Certificate F1.7006 R10 C CAC Letter- ASTM D316J te(ter fci-: fi- 2i)I71 frgm FM.12x1 FL7006 RIOT CAC Letter- SA TM D3 2_I_etter- (9 26- M W.,zft FL7006 R10 C CAC Letter - ASTM El08 letter - (e-76- 2017). L Quality Assurance Contract Expiration Date 12/20/2020 Installation Instructions FL7006 111.0 II IKO-187-O-Qi_Letter - Installation Instructions for F—QC FL7006.0fjf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: Back Hext Canto 1 :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: $50-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibdlty Statement :: Refund Stnlement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mad. If you have any questions, please contact 850.487.1395. TPursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The entails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee tinder Chapter 455, F.S., please cllck here . Product Approval Accepts: -ga;C mg Credit Card Safe installation Instructions for As' halt Shingles Palle 4 of 5 IKO Hip and Ridge 12 Application Instructions (ASTM D3161, Ciass F — IKO Hip and Ridge 12) THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED ATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CT, THESE INSTRUCTIONS WILL GOVERN. but hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are Oesigned for a 51/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has been factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of,the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional effect, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE: SHINGLES MUST BE APPLIED PROPERLY. THEY ARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. + . (19 MM) T A PER CUB 0mrn) J(13 6 am, (162m ) PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 a -mail: materialstesling@pricmtcom WebSite: http:Nwww.pricmtcom ation Instructions for ilt Shingles 3of5 IKO Laminated Shingles Application Instructions -- - - (ASTM D3161, Class F — Cambridge, Cambridge HD, and CRC Biltmore AR) THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED NTION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CT, THESE INSTRUCTIONS WILL GOVERN. DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4 per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1" and 13" in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2 of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". 6 31 NAIL LINE NAILING - STEEP SLOPES APPLICATION Use six nails as shown. El ��-J CEMENT PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OFTHE SHINGLE PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: B13-621.5777 Fax: 813-621-5840 e-mail: materialstesting@pricmtcom WebSite: http:/Avww.pricmtcom ation Instructions for Ilt Shingles 2of5 IKO Shingle Application Instructions — 3-Tab Shingles (ASTM D3161, Class F — IKO Marathon 25 AR and CRC Superglass M25AR) OTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED PPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION ONFLICT, THESE INSTRUCTIONS WILL GOVERN. F DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4 per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated)'roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2 above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES 1 - - -� - -- SEAUNG STRIP - - • • i • • 6118" 2" I I 6-1/8' NAILS NAILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP PRI Construclion Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: B13-621-5777 Fax: 813-621-5840 e-mail: matedaistesting@pdcmt.com WebSite: http://www.pricmtcom CONSTRUCTION MATERIALS, TECHNOLOGIES 27, 2017 KO Industries, Ltd 120 Hay Rd. Nilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions — 3-Tab Shingles (EN-3Tab Appins_8AGXEFS-2012-11 reformatted 2013-02-rev07/13-Florida) 2) IKO Laminated Shingles Application Instructions (EN -Laminated Appins_8TTEFS-2012-04_reformatted 2013-02-rev07/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions (EN-HipandRidge 12_3HRTri-2013-08_reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions (EN-3LEP-Tri-2012-06_reformatted 2013-03) 5) ASTM D3.161 Test Report (FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. 0 Signed: Signed: Brad Grcybo ski Duc T. u en Managing Director Florida Re ere Professional Engine r P.E. Number: 65034 Date: October 27, 2017 Date: October 27, 2017 Attachments: A) IKO Shingle Application Instructions - 3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-187-02-01 PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materialstesting@pricmtcom WebSite: http://Www.pdcmt.com "Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions (ASTM D3161, Class F — IKO Leading Edge Plus) OTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED PPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION ONFLICT, THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required. 2. Each 39 3/8" x 1.31/4" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8" x 6 5/8" (1000 mm x 168 mm) and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge and 1" (25 mm) in from each end. 4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang the rake edge by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners located 3" to 4" (75 mm to 100 mm) from the rake edge and 1" (25 mm) in from each end. 5. Repeat Steps 3 — 4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4" (20 mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm) from the eave edge and approximately 1" and 13" (25 mm and 330 mm) in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingles to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and help keep them from lifting in high winds. M1 PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: mate6alstesfing@pdcmt.com WebSite: http://www.pricmLcom I 7/6/2018 Florida Building Cod- n-line � �arrw.M 'law OF CANNED , ProfessionalRegulation 1BY - �`f �i�te. Co ,.. rarer BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search rn! I Product Approval USER: Public User ProductAporovai Menu > Product or ADolication Search > ADDlication uleg > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL16048-R6 Revision 2017 Approved (NI RECEIVED E JUL 0 9 2018 ST. Lucie County, Permitting Tri=Built Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800)516-1485 david.ruiz@tribuiltmg.com' David Ruiz david.ruiz@tribuiltmg.com David Ruiz 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david.ruiz@tribuiltmaterialsgroup.com FILE COPY Roofing Underlayments Evaluation Report from a Florida Registered Architect_or a Licensed Florida Professional Engineer O Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By John W. Knezevich, PE OO Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) 'Equivalence of Product Standards Certified By FL16048 R6 COI 2017 01 COI Nieminen.adf Standard ASTM D1970 ASTM G155 FM 4474 FRSA/TRI April 2012 (04-12) UL 1897 Year 2015 2005 2011 2012 2012 Sections from the Code idirig.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWrwipmtAnR8jvgFiYHTk4FLCxcgVtRhfvMw%3de/a3d 1 /2 7/6/2018 Florida Building Coc'- ^-line Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 10/01/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 16048.1 TRI-BUILT Roof Underlayments Self -adhering, modified bitumen roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL16048 R6 II 2017 09 FINAL ER TRI- Approved for use outside HVHZ:_Yes BUILT. UNDERLAYMENTS FL16048-R6.pddf. Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure, +N/A/-150 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to use of Evaluation Reports foam -on tile systems overtop the self -adhering underlayment FL16048 R6 AE 2017 09 FINAL ER TRI- for one particular application. See ER Section 5.6.4 for details. BUILT UNDERLAYMENTS FL16048-R6.pdf 2.) Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copy Li ht 2007-2013 State of Florida.:: Privacy Statement :: Accessiblllty Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by.phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for ofFlcial communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® eClrect. -kar Credit -Card Safe _app_dtl.aspx?param=wG EVXQwtDgtFPmdYiNDWrwipmtAnR8jv9FiYHTk4FLCxcgVtRhfvMw%3d%3d 2/2 y TRINITY I ERD :VALUATION REPORT RI -BUILT Materials Group, LLC 0 Box 70 erford, NJ 07070 1516-1485 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization ##9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report A42960.10.12-116 FL16048-R6 Date of Issuance:10/25/2012 Revision 6: 09/25/2017 "this Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of liconstruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the. product under the Florida Building Code and Florida Building Code, Residential Volume. The it products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: xxx Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/25/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinityIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing product's for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. is Q0TP..1N1TYJERb_ ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with the following. Standards. Compliance is subject to the Installation Requirements and Limitations Conditions of Use set forth herein. 2. STANDARDS: Section 1504.3.1 1504.3.1 1504.6 1507.2.4 / 1507.1.1, 1507.2.9.2 1507.3.3 3. REFERENCES: Entity ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) UL, L-C. (QUA9625) UL, L-C. (QUA9625) 4. PRODUCT DESCRIPTION: 5 Property Wind Resistance Wind Uplift Accelerated Weathering Physical Properties Physical Properties Examination Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Accelerated Weathering Wind Resistance Quality Control Quality Control Standard FM 4474 U L 1897 ASTM G155 ASTM D1970 FRSA/TRI April 2012 (04-12) Reference S40540.02.13-1 S40540.11.13 S40540.03.14 S44870.04.14-2 S44870.04.14-3 S44870.04.14-1 S44870.04.14-4 S43530.02.14-1-R1 S43530.05.14 S40540.10.14 SC7645.02.15 SC8520.04.15 SC14045.05.17-R1 Multiple -Listing R16814 Service Confirmation Year 2011 2012 2005 2015 2012 Date 02/19/2013 11/19/2013 03/26/2014 04/02/2014 04/02/2014 04/10/2014 04/10/2014 05/14/2014 05/28/2014 10/31/2014 02/13/2015 05/27/2015 06/07/2017 12/10/2015 Exp.07/18/2020 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced,'sand-surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 2 of 6 I I! TRINITY I ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Nail -On Tile Foam -On Tile Metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Approval Underlayments ICP Adhesives Polyset® AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TileBondT1 FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D orTAS 114, AppendixJ. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 3 of 6 5.6.3 5.6.4 VNTINITYIERO Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment; Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226, Type I or II felt. For installations under mechanically attached prepared roof coverings; base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deep underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on, allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastoeol 600c Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #3 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners .shall be driven flush with the surface. All sharpi splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER I, Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand'! roller and/or weighted roller to ensure there are no voids, and ensure there are no, voids/bridging at side and end -laps. #4 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Underlayment: Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Tri-Built S/A HT TU Underlayment, self -adhered. I Evaluation Report A42960.10.12-R6 6T" EDITION (2017) FBC NON-HVHZ EVALUATION 'FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 4 of 6 TRINITY I ERD 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Maximum Underlayment Tile Profile Staging Method Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Tri-Built S/A HT TU Underlayment Lugged I Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 5 of 6 TRINITY I ERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof, cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3. Tile Applications (Tri-Built S/A HT TU Underlayment only): Reference'is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI=BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS I�. 9. QUALITY ASSURANCE ENTITY: UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.16048-116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 6 of 6 7/6/2018 Florida Building Code Online4T OF - CANN50 j 13Y & Professional Regulation St. Lucie CountY BE - _ BCIS Home •I Log In I User Registration- I Hot Topics Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links Search I La ::p./Product Approval WUSER: Public User Product Approval Menu > Product or Application Search > eRplication List > Application Detail - 1 RECEIVED FL # FL16027-R2 F. Application Type Revision J U I 0 9 1 9 Code Version 2017 L rJ Application Status Approved ST. Lucie County, Permitting Comments Archived O Product Manufacturer Tri-Built Materials Group, LLC Address/Phone/Email PO Box 70 Rutherford, NJ 07070 (800) 516-1485 ' david.ruiz@tribuiltmg.com Authorized Signature David Ruiz david.ruiz@tribuiltmg.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North FILE�� P� East Rutherford, NJ 07073 (201) 842-2449 david.ruiz@tribuiltmaterialsgroup.com Quality Assurance Representative C Richard Schurman Address/Phone/Email 9050 Louisiana Street Merrillville, IN 46410 rich.schurman@alliedbuilding.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer U Evaluation Report : Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE O Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL16027 R2 COI 2017 01 COI Niemineh.pdf Standard ASTM D6163 ASTM D6164 ASTM D6222 FM 4470' FM 4474 Year 2008 2011 2011 2012 2011 Equivalence of Product Standards Certified By .org/pr/pr_app_dtl.aspx? pa ra m=wG EVXQwtDgtFPmdYi N D Wrxtft9YUwv%2fLXRbpak6f2jJ G iyowhtbu4Q%3d%3d 1/2 7/6/2018 Sections from the Code Florida Building Code Online — Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/25/2017 09/30/2017 10/08/2017 12/12/2017 FL # Model, Number or Name Description 16027.1 TRI-BUILT Modified Bitumen Roof SBS and APP modified bitumen roof systems - Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1602Y R2 .II 2017 09 FINAL Al ER TRI- Approved for use outside HVHZ: Yes BUILT MODBIT FL16027-R2.pddf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The Design Pressure noted in this application refers Evaluation Reports to one system. Refer to ER Appendix for all systems and max. FL16027 . R2 AE 2017. 09 FINAL ER TRI- design pressures. 2.) Refer to ER Section 5 for Limits of.Use. BUILT MODBIT FL16027-R2.pdf Created by Independent Third Party: Yes Back Next _ Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessiblllty Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses.are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: . ®. ® e0heck .Ctedit-Card: Safe https {floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDVVrxtf9YUwv%2fLXRbpak6f2jJGiyowhtbu4Q%3d%3d 2/2 0 i EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 TR�N�TY I 353 Christian Street ERD Oxford, CT 06478 (203) 262-9245 VALUATION REPORT RI -BUILT Materials Group, LLC Evaluation Report A42970.10.12-R2 O Box 70 FL16027-R2 utherford, NJ 07070 Date of Issuance:10/23/2012 300) 516-1485 Revision 2: 09/25/2017 I his Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of 1construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, :P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted I' herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product !; changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. it ADVERTISEMENT -.The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. �1 This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/25/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity i ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINIT ' i ERD APPENDIX 1 ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE _ ;' - ie( i Table Deck Application Type Description III Page 3A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover j 4 IA-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded. Roof Cover 6 1E-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 lE-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 8 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 10 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 56 CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 SC CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 23 613 Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24 6D Gypsum. New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 7B Various Recover' F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 26 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: Y Wood: Minimum 0.75-inch penetration. 1 Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. 'i Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturers published installation instructions. 3. r Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the OA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-112 for FL16027-R2 Certificate of Authorization #9503 bra EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516.1485 Appendix 1, Page 1 of 26 ��TRINITYJERD 15. Unlessl otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE I: TRI-BUILT ROOF COVERS I'1 Reference Layer Material Application BP`'AA (Ba��e and Ply sheets, Asphalt -Applied) Base Ply FBC Approved ASTM D4601, Type II HA at 20-40 Ibs/square Ply FBC Approved ASTM D2178, Type IV or VI S "IAA (SBS, Asphalt -Applied) Cap Ply TriBuilt SBS Granular HA at 20.40 Ibs/square SBSLTA LLd� (Silts, Torch -Applied) Cap Ply TriBuilt SBS Granular _ Torch -Applied SB ,I, 4p, Self -Adhering) Base Ply TriBuilt SA SBS Base Self -Adhering Cap Ply TriBuilt SA SBS Cap ApIp-TA (ARP, Torch -Applied) Base Ply or Ply TriBuilt APP Smooth Torch -Applied Cap Ply TriBuiltAPP ,Smooth, TriBuilt APP Granular API SA (, P, Self -Adhering) Cap Ply TriBuilt SA APP Cap Self -Adhering 16. ao I'p— barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A p' V4POR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A W 0 tionIt II Primer Vapor Barrier Insulation Adhesive _ MD Type Attach 1I,VB-1. ASTMD41 T' Base Self -Adhering I nta-Stik or CR-20, 12-inch o.c. -60.0 �I IVB-2. ASTM D41 S Cap Self -Adhering Insta-Stik, 12-inch o.c. - IIJVB-3. ASTM D41 rl S Cap Self -Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5 III,IVB-4. ASTM D41 ThBuilt SA SBS Cap Self -Adhering CR-20, 12-inch o.c. -270.0 VB-S. ASTM D41 TriBuilt SA SBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0 17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. IIII 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL36027-112 to of Authorization k9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 i by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516.1485 Appendix 1, Page 3 of 26 I I TRINITY I ERD TABLE 1E-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER . ` SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER i System I Base Sheet Roof Cover (Note 15) j MDP No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply (Psf) Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-Inch lap and 12-inch (Optional) One or W-1 plywood at max. poly, Polyglass G2 Base, CertalnTeed Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. in two, equally spaced, staggered more BP -AA or SBS-AA, SBS- -52.5 24-inch spans Glasbaolyse, Firestone MB Base, JM Parma- or TruFast MP-3 with TruFast HD center rows APP-TA TA, APP•TA Ply 28, Tamko Glass Base or GAFGLAS #75 Min. 19/32-Inch Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 or TruFast MP- 12-inch o.c. in 4-Inch lap and 12-Inch One or more 585- SBS-SA, APP- W-2 plywood at max. Elastobase Poly top 3 TruFast HD o.c. In two, equally spaced, staggered SA SA, SBS-TA or -52.5' 24-inch spans with poly surface with center rows APP-TA Min. 19/32-Inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. In 4-inch lap and 12-Inch (Optional) One or SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o.c. In two, equally spaced, staggered more BP -AA or TA, APP-TA -60.0 24-inch spans center rows APP-TA .Min. 19/32-Inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-Inch One or more SBS- SBS-SA, APP- W-4 plywood at max. Roofgrip #12 o.c. in two, equally spaced, staggered SA SA, SBS-TA or -60.0' 24-Inch spans Elastobase Poly with poly top surface - center rows APP-TA TABLE 1F: WOOD DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER q System Roof Cover (Note 15) MOP N Deck Prim Joint Treatment Base Ply Ply Cap Ply (Psf) -S Min. 15/32-in plywood (Optlona STM D41 None SBS-SA Optional) (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA at max. 24-in h spans APP-TA or APP-TA W-6 (Optional) ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TriBuilt SA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA ,-97.5 at max. 24-inch spans SBS Base, rolled Into place to create continuous bond. APP-TA or APP-TA Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516.1485 Appendix 1, Page 8of 26