HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLES4
11 j� � •-
scai�I �o paE J 1 7 ••'Sr+-z ,xspv.. � ..�
I � i jy, r � r. r ..-u:'d+•6
f�- 176
C-y ,y1 �f' '�,� j•�, -. y�j}g 6 - 1,r.BY�'o p�r�
�+.aV,V 'I.BOWIBU µ•. {a :A� c.;a� .rFw•``,
n
1..`�..Is4..� » f '`.. .."..J,,{. f....-'-.r.kc.r,.::::f.'� Lour.:.„sue_.. v...'L it F
BCIS dome I Log In i User Registration ; Hot Topics I Submit Surebarge ( Slats & Facts j Publications 1 'Contact us i SCIS Site Map Links ! Search
�t{lflfil
Product Approval
Ind USER; Public User
` Prnnnrt Annrrn al hteMI > Prang? or Fpntkiuon SYIDCh > pnnlicotrnn I ist > Application Detail RECEIVED
2 h, `r' FL # FL7006-R10
j Application Type Revision J U L 9 9 2018
i
Code Version 2017
Application Status Approved
i ST. Lucie County PermiGziflg
I 'Approved by DBPR. Ap couals.-by-DSP-R=shaTf-{re re ratified by
the POC and/or the Commission If necessary.
FILE COPY
Comments
I� Archived .i
Product Manufacturer IKO Industries, Ltd
Address/Phone/Email 40 Hansen Road South
Brampton, NON -US L6W 3H4
(708)496-2800 Ext200
rmetz001@tanpabay. rr.com
Authorized Signature
Robert Metz
rmetzOOI@tampabay.rr.com
CONCEALED FAST ENERS OB AI i AC! I1PIcrU —IS
Technical Representative
Bob Metz ARE THE RESPONSIBILITY OF THE
Address/Phone/Email
REMCO of Pinellas GOi tRACTOR OR RECORD
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
rmetzOOI@tampabay.rr.com
Quality Assurance Representative
Don Shaw
Address/Phone/Email
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579.6706
don.shaw@lko.com
THESE PLANS AND ALL PROPOSED WORK
Category
Roofing ARE SUBJECT TO ANY CORRECTIONS
Subcategory
Asphalt Shingles REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
Compliance Method
Certification Mark or Listing COMPLY WITH ALL APPLICABLE CODES.
Certification Agency
FM Approvals - CER
Validated By
Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard Year
ASTM D3161 modified to 110 mph 2016
ASTM D3462 2010
ASTM D7158 Class H 2O11
ASTM Ei08 2011
Equivalence of Product Standards
' G,
Certified By
00
IL
/ ��u ,rfLPIC'?ls
ST. LUCIE COUNTY BUILDING DI' ON —
REVIEWED FOR COMPLIANCE
REVIEW
DATE
PLANS A D PERMIT MUST BE K ON JOB
SITE OR NO INSPECTIONS) V? L BE MADE
I�
y IV�
l
Product Approval Method Method i Option A
Date Submitted 10/08/2017
Date Validated 10/30/2017
Date Pending FBC. Approval
Date Approved 11/01/2017
FL # Model, Number or Name Description
7006.1 Cambridge, Cambridge HD, Biltmore Laminated architectural fiberglass asphalt shingle
and Biltmore HD manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.;
Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Deslgn Pressure: N/A
Other:
Certification Agency Certiflcate
FL7006 R10 C CAC Letter - ASTM Q3161 letter - (9-26-
20171 from FM.ndf
FL7006 RIO C CAC letter - ASTM D3462 letter - (9-26-
20171.pdf
FI 7006 RIO C CAC Lett - ASTM E108 letter - (9-26-
20171.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
F1 7006 R10 II IKO-187-02-01 Letter - installation
instructions for FBC FL7006ndf
Verified. By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
7006.2
Hip and Ridge 12 Cap
This Is a 12' x 12' fiberglass asphalt shingle used to cover the
hip and/or ridge of an asphalt shingle roof system
manufactured at iKO's Kankakee, IL, Toronto, Ont. and
Brampton, Ontario plants.
Limits of Use
Certification Agency Certificate
FL7006 R10 C GAG ASTM D 3462 - Shinale let_te
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Surveillance Audit Location - (6-28-20171.pdf
f1-7006 RIO C CAC Letter - ASTM D3161_letter - (9-26-
20171from FM.Ddf
FL7006 R10 C CAC Letter - ASTM D3462 letter - (9-26-
Other:
2017).ndf
FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26-
20171.11dF
Quality Assurance Contract Expiration Date
22/31/2020
Installation Instructions
FL7006 R10 11 Hip and Ridge Cap Shingle installation
i'nstnictions.pdf
FL7006 RIO 11 iKO-187-02-01 Letter - installation
instructions for FBC FL7006.ndf
Verified By: Duc T Nguyen PE 6SO34
Created by Independent Third Parry, No
Evaluation Reports
Created by Independent Third Parry:
7006.3
Leading Edge Plus Asphalt Shingle
Starter Strip
One piece fiberglass asphalt shingle used as a starter strip at
the bottom of a roof system manufactured in Brampton and
Hawkesbury, Ontario plants
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Certification Agency Certificate
FL7006 RIO C CAC Letter - ASTM D3161 letter - ( 26_
20171 from FM.pdF
FL7006 RIO- C CAC Letter - ASTM D3462 letter - (9-26-
Impact Resistant: N/A
20171.11df -_
(9-26-
Design Pressure: N/A
Dther:
FL700b R10 C CAC Letter ASTM F108 letter -
20171.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 Rio ff iKO-187-02-01 Letter - installation
Instructions for FBC FL7006 ndf
FL7006 RIO 11 Roofing -Products -Leading Fdne-Plus-
Application-FN(11.pdf
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Parry: No
Evaluation Reports
Created by Independent Third Party:
7006.4 Marathon Plus AR, Superglass Plus 3 tab fiberglass asphalt shingle manufactured at iKUS
AR Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.;
Sylacauga, AL and Kanakakee,IL plants
.y
i
`e
Limits of Use
Approved for use in HVH2: Yes
Approved for use outside HVH2: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Certification Agency Certificate
F1.7006 R10 C CAC Letter- ASTM D316J te(ter fci-: fi-
2i)I71 frgm FM.12x1
FL7006 RIOT CAC Letter- SA TM D3 2_I_etter- (9 26-
M W.,zft
FL7006 R10 C CAC Letter - ASTM El08 letter - (e-76-
2017). L
Quality Assurance Contract Expiration Date
12/20/2020
Installation Instructions
FL7006 111.0 II IKO-187-O-Qi_Letter - Installation
Instructions for F—QC FL7006.0fjf
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
Back Hext
Canto 1 :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: $50-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibdlty Statement :: Refund Stnlement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mad. If you have any questions, please contact 850.487.1395. TPursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The entails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee tinder Chapter 455, F.S., please cllck here .
Product Approval Accepts:
-ga;C mg
Credit Card
Safe
installation Instructions for
As' halt Shingles
Palle 4 of 5
IKO Hip and Ridge 12 Application Instructions
(ASTM D3161, Ciass F — IKO Hip and Ridge 12)
THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
ATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CT, THESE INSTRUCTIONS WILL GOVERN.
but hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are
Oesigned for a 51/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has
been factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5
5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm).
Apply hip pieces starting at the lower end of,the hip, working up toward the ridge. On hip roofs, apply ridge
pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end
opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional
effect, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2
pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see
diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be
covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for
easier bending.
NOTE: SHINGLES MUST BE APPLIED PROPERLY. THEY ARE DESIGNED FOR USE AS HIP AND RIDGE
SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO
RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO
PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER
VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW
ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR
TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS.
+
. (19
MM)
T A PER CUB
0mrn)
J(13
6 am,
(162m )
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 a -mail: materialstesling@pricmtcom WebSite: http:Nwww.pricmtcom
ation Instructions for
ilt Shingles
3of5
IKO Laminated Shingles Application Instructions -- - -
(ASTM D3161, Class F — Cambridge, Cambridge HD, and CRC Biltmore AR)
THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
NTION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CT, THESE INSTRUCTIONS WILL GOVERN.
DECK: Solidly sheathed and fastened deck conforming to 2017 FBC.
UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping
each preceding course by 19" or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4 per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long
enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-3/8"
below the top edge, approx. 1" and 13" in from each end. Drive nails straight so that nail head is flush with,
but not cutting into shingle surface.
NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2 of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8".
6 31
NAIL LINE
NAILING - STEEP SLOPES APPLICATION
Use six nails as shown.
El ��-J
CEMENT
PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OFTHE SHINGLE
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: B13-621.5777 Fax: 813-621-5840 e-mail: materialstesting@pricmtcom WebSite: http:/Avww.pricmtcom
ation Instructions for
Ilt Shingles
2of5
IKO Shingle Application Instructions — 3-Tab Shingles
(ASTM D3161, Class F — IKO Marathon 25 AR and CRC Superglass M25AR)
OTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
PPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
ONFLICT, THESE INSTRUCTIONS WILL GOVERN.
F DECK: Solidly sheathed and fastened deck conforming to 2017 FBC.
UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping
each preceding course by 19" or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4 per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING: Use galvanized (zinc coated)'roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long
enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt
edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is
flush with, but not cutting into shingle surface.
NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt
plastic cement placed under the shingle 2 above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8".
STEEP SLOPES
1
- - -� - -- SEAUNG STRIP - - • • i • •
6118" 2" I I 6-1/8'
NAILS NAILS
DO NOT NAIL INTO OR ABOVE THE SEALING STRIP
PRI Construclion Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: B13-621-5777 Fax: 813-621-5840 e-mail: matedaistesting@pdcmt.com WebSite: http://www.pricmtcom
CONSTRUCTION MATERIALS,
TECHNOLOGIES
27, 2017
KO Industries, Ltd
120 Hay Rd.
Nilmington, DE 19809
Re: FBC FL7006
Sir(s),
PRI Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2017 Florida Building Code.
This review was completed based on the receipt of following evidence from IKO Industries, Ltd:
1) IKO Shingle Application Instructions — 3-Tab Shingles
(EN-3Tab Appins_8AGXEFS-2012-11 reformatted 2013-02-rev07/13-Florida)
2) IKO Laminated Shingles Application Instructions
(EN -Laminated Appins_8TTEFS-2012-04_reformatted 2013-02-rev07/13-Florida)
3) IKO Hip and Ridge 12 Application Instructions
(EN-HipandRidge 12_3HRTri-2013-08_reformatted 2013-08)
4) IKO Leading Edge Plus Shingle Application Instructions
(EN-3LEP-Tri-2012-06_reformatted 2013-03)
5) ASTM D3.161 Test Report (FM Approvals Project No. 3040947)
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and applicable code. In the event the instructions conflict, these instructions shall govern.
Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued.
0
Signed: Signed:
Brad Grcybo ski Duc T. u en
Managing Director Florida Re ere Professional Engine r
P.E. Number: 65034
Date: October 27, 2017 Date: October 27, 2017
Attachments: A) IKO Shingle Application Instructions - 3-Tab
B) IKO Laminated Shingles Application Instructions
C) IKO Hip and Ridge 12 Application Instructions
D) IKO Leading Edge Plus Application Instructions
IKO-187-02-01
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materialstesting@pricmtcom WebSite: http://Www.pdcmt.com
"Installation Instructions for
Asphalt Shingles
Page 5 of 5
IKO Leading Edge Plus Application Instructions
(ASTM D3161, Class F — IKO Leading Edge Plus)
OTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
PPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
ONFLICT, THESE INSTRUCTIONS WILL GOVERN.
1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required.
2. Each 39 3/8" x 1.31/4" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for
separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to
separate.
3. Take one of the separated shingles 39 3/8" x 6 5/8" (1000 mm x 168 mm) and remove approximately
20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the
factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves
by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4" (75
mm to 100 mm) from the eave edge and 1" (25 mm) in from each end.
4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge
with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang
the rake edge by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners
located 3" to 4" (75 mm to 100 mm) from the rake edge and 1" (25 mm) in from each end.
5. Repeat Steps 3 — 4 for the right lower corner of the roof deck.
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least
3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4" (20
mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm) from
the eave edge and approximately 1" and 13" (25 mm and 330 mm) in from each end.
6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install
the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles
should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingles to
the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle.
7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first
course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way,
the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and
help keep them from lifting in high winds.
M1
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: mate6alstesfing@pdcmt.com WebSite: http://www.pricmLcom
I
7/6/2018
Florida Building Cod- n-line
� �arrw.M
'law OF CANNED ,
ProfessionalRegulation 1BY -
�`f �i�te. Co
,.. rarer
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search
rn! I Product Approval
USER: Public User
ProductAporovai Menu > Product or ADolication Search > ADDlication uleg > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL16048-R6
Revision
2017
Approved
(NI
RECEIVED
E
JUL 0 9 2018
ST. Lucie County, Permitting
Tri=Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800)516-1485
david.ruiz@tribuiltmg.com'
David Ruiz
david.ruiz@tribuiltmg.com
David Ruiz
250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
FILE COPY
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect_or a Licensed Florida
Professional Engineer
O Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich, PE
OO Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
'Equivalence of Product Standards
Certified By
FL16048 R6 COI 2017 01 COI Nieminen.adf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 (04-12)
UL 1897
Year
2015
2005
2011
2012
2012
Sections from the Code
idirig.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWrwipmtAnR8jvgFiYHTk4FLCxcgVtRhfvMw%3de/a3d
1 /2
7/6/2018 Florida Building Coc'- ^-line
Product Approval Method Method 1 Option D
Date Submitted
09/25/2017
Date Validated
10/01/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ:_Yes
BUILT. UNDERLAYMENTS FL16048-R6.pddf.
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure, +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use of
Evaluation Reports
foam -on tile systems overtop the self -adhering underlayment
FL16048 R6 AE 2017 09 FINAL ER TRI-
for one particular application. See ER Section 5.6.4 for details.
BUILT UNDERLAYMENTS FL16048-R6.pdf
2.) Refer to ER Section 5 for other Limits of Use.
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copy Li ht 2007-2013 State of Florida.:: Privacy Statement :: Accessiblllty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by.phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for ofFlcial communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® ® eClrect. -kar
Credit -Card
Safe
_app_dtl.aspx?param=wG EVXQwtDgtFPmdYiNDWrwipmtAnR8jv9FiYHTk4FLCxcgVtRhfvMw%3d%3d
2/2
y
TRINITY I ERD
:VALUATION REPORT
RI -BUILT Materials Group, LLC
0 Box 70
erford, NJ 07070
1516-1485
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization ##9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report A42960.10.12-116
FL16048-R6
Date of Issuance:10/25/2012
Revision 6: 09/25/2017
"this Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
liconstruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the. product under the Florida Building Code and Florida Building Code, Residential Volume. The
it products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
xxx
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/25/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. TrinityIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing product's for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
is
Q0TP..1N1TYJERb_
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code through testing
in accordance with the following. Standards. Compliance is subject to the Installation Requirements and Limitations
Conditions of Use set forth herein.
2. STANDARDS:
Section
1504.3.1
1504.3.1
1504.6
1507.2.4 / 1507.1.1, 1507.2.9.2
1507.3.3
3. REFERENCES:
Entity
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
UL, L-C. (QUA9625)
UL, L-C. (QUA9625)
4. PRODUCT DESCRIPTION:
5
Property
Wind Resistance
Wind Uplift
Accelerated Weathering
Physical Properties
Physical Properties
Examination
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Accelerated Weathering
Wind Resistance
Quality Control
Quality Control
Standard
FM 4474
U L 1897
ASTM G155
ASTM D1970
FRSA/TRI April 2012 (04-12)
Reference
S40540.02.13-1
S40540.11.13
S40540.03.14
S44870.04.14-2
S44870.04.14-3
S44870.04.14-1
S44870.04.14-4
S43530.02.14-1-R1
S43530.05.14
S40540.10.14
SC7645.02.15
SC8520.04.15
SC14045.05.17-R1
Multiple -Listing R16814
Service Confirmation
Year
2011
2012
2005
2015
2012
Date
02/19/2013
11/19/2013
03/26/2014
04/02/2014
04/02/2014
04/10/2014
04/10/2014
05/14/2014
05/28/2014
10/31/2014
02/13/2015
05/27/2015
06/07/2017
12/10/2015
Exp.07/18/2020
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced,'sand-surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 2 of 6
I
I! TRINITY I ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
&Shingles
Tri-Built Sand-R SA Shingle
Yes
No
No
No
Yes
Yes
Underlayment
Tri-Built S/A HT TU
Yes
Yes
Yes
Yes
Yes
Yes
Underlayment
See 5.5.1
Tri-Built Smooth HT S/A
Yes
No
No
Yes
Yes
Yes
Underlayment
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS)
Adhesive
Florida Product Approval
Underlayments
ICP Adhesives Polyset® AH-160
FL6332
Tri-Built S/A HT TU Underlayment
Dow TileBondT1
FL22525
Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D orTAS 114, AppendixJ.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 3 of 6
5.6.3
5.6.4
VNTINITYIERO
Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment; Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings; base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deep
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the
applications. Maximum Design Pressure is the result of testing for wind load resistance based on,
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure = -45.0 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
(Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
Soprema Elastoeol 600c
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure = -150.0 psf:
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners .shall be driven flush with the surface. All sharpi
splinters and wood projections shall be removed/sanded.
Primer:
(Optional) RESISTO EXTERIOR PRIMER I,
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand'!
roller and/or weighted roller to ensure there are no voids, and ensure there are no,
voids/bridging at side and end -laps.
#4 Maximum Design Pressure = -60.0 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Underlayment:
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Tri-Built S/A HT TU Underlayment, self -adhered.
I
Evaluation Report A42960.10.12-R6
6T" EDITION (2017) FBC NON-HVHZ EVALUATION 'FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 4 of 6
TRINITY I ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Maximum
Underlayment
Tile Profile
Staging Method
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
Tri-Built S/A HT TU
Underlayment
Lugged
I
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 5 of 6
TRINITY I ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof,
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3. Tile Applications (Tri-Built S/A HT TU Underlayment only):
Reference'is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI=BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
I�.
9. QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.16048-116
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 6 of 6
7/6/2018
Florida Building Code Online4T OF -
CANN50 j
13Y
& Professional Regulation St. Lucie CountY BE
- _
BCIS Home •I Log In I User Registration- I Hot Topics Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links Search I
La ::p./Product Approval
WUSER: Public User
Product Approval Menu > Product or Application Search > eRplication List > Application Detail - 1
RECEIVED
FL # FL16027-R2 F.
Application Type Revision J U I 0 9 1 9
Code Version 2017 L rJ
Application Status Approved ST. Lucie County, Permitting
Comments
Archived O
Product Manufacturer Tri-Built Materials Group, LLC
Address/Phone/Email PO Box 70
Rutherford, NJ 07070
(800) 516-1485 '
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North FILE�� P�
East Rutherford, NJ 07073
(201) 842-2449
david.ruiz@tribuiltmaterialsgroup.com
Quality Assurance Representative C Richard Schurman
Address/Phone/Email 9050 Louisiana Street
Merrillville, IN 46410
rich.schurman@alliedbuilding.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
U Evaluation Report : Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W. Knezevich, PE
O Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL16027 R2 COI 2017 01 COI Niemineh.pdf
Standard
ASTM D6163
ASTM D6164
ASTM D6222
FM 4470'
FM 4474
Year
2008
2011
2011
2012
2011
Equivalence of Product Standards
Certified By
.org/pr/pr_app_dtl.aspx? pa ra m=wG EVXQwtDgtFPmdYi N D Wrxtft9YUwv%2fLXRbpak6f2jJ G iyowhtbu4Q%3d%3d
1/2
7/6/2018
Sections from the Code
Florida Building Code Online —
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/25/2017
09/30/2017
10/08/2017
12/12/2017
FL #
Model, Number or Name
Description
16027.1
TRI-BUILT Modified Bitumen Roof
SBS and APP modified bitumen roof systems
-
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1602Y R2 .II 2017 09 FINAL Al ER TRI-
Approved for use outside HVHZ: Yes
BUILT MODBIT FL16027-R2.pddf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The Design Pressure noted in this application refers
Evaluation Reports
to one system. Refer to ER Appendix for all systems and max.
FL16027 . R2 AE 2017. 09 FINAL ER TRI-
design pressures. 2.) Refer to ER Section 5 for Limits of.Use.
BUILT MODBIT FL16027-R2.pdf
Created by Independent Third Party: Yes
Back Next _
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessiblllty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses.are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
. ®. ® e0heck
.Ctedit-Card:
Safe
https {floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDVVrxtf9YUwv%2fLXRbpak6f2jJGiyowhtbu4Q%3d%3d 2/2
0
i EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
TR�N�TY I 353 Christian Street
ERD Oxford, CT 06478
(203) 262-9245
VALUATION REPORT
RI -BUILT Materials Group, LLC Evaluation Report A42970.10.12-R2
O Box 70 FL16027-R2
utherford, NJ 07070 Date of Issuance:10/23/2012
300) 516-1485 Revision 2: 09/25/2017
I his Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
1construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
:P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
I' herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
!; changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
it ADVERTISEMENT -.The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
�1 This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/25/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity i ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity l ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINIT ' i ERD
APPENDIX 1 ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
_ ;' -
ie( i
Table
Deck
Application
Type
Description
III Page
3A-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
j 4
IA-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded. Roof Cover
6
1E-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
7
lE-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
8
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
9
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
10
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
11-14
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
14
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
15-16
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
16
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
17-19
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
20
56
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
21
SC
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
22
SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22
6A
Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover
23
613
Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
24
6C
Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover
24
6D
Gypsum. New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
24
7A
Various Recover A-1 Bonded Insulation, Bonded Roof Cover
25-26
7B
Various Recover' F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
26
The following notes apply to the systems outlined herein:
1.
The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2.
Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
Y Wood: Minimum 0.75-inch penetration.
1 Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
'i Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturers published installation instructions.
3.
r
Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the OA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-112 for FL16027-R2
Certificate of Authorization #9503 bra EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516.1485 Appendix 1, Page 1 of 26
��TRINITYJERD
15. Unlessl otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE I: TRI-BUILT ROOF COVERS
I'1 Reference
Layer
Material
Application
BP`'AA
(Ba��e and Ply sheets, Asphalt -Applied)
Base Ply
FBC Approved ASTM D4601, Type II
HA at 20-40 Ibs/square
Ply
FBC Approved ASTM D2178, Type IV or VI
S "IAA
(SBS, Asphalt -Applied)
Cap Ply
TriBuilt SBS Granular
HA at 20.40 Ibs/square
SBSLTA
LLd�
(Silts, Torch -Applied)
Cap Ply
TriBuilt SBS Granular _
Torch -Applied
SB
,I,
4p, Self -Adhering)
Base Ply
TriBuilt SA SBS Base
Self -Adhering
Cap Ply
TriBuilt SA SBS Cap
ApIp-TA
(ARP, Torch -Applied)
Base Ply or Ply
TriBuilt APP Smooth
Torch -Applied
Cap Ply
TriBuiltAPP ,Smooth, TriBuilt APP Granular
API SA
(, P, Self -Adhering)
Cap Ply
TriBuilt SA APP Cap
Self -Adhering
16. ao I'p—
barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
p'
V4POR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A
W
0 tionIt
II
Primer
Vapor Barrier
Insulation Adhesive _
MD
Type
Attach
1I,VB-1.
ASTMD41
T' Base
Self -Adhering
I nta-Stik or CR-20, 12-inch o.c.
-60.0
�I IVB-2.
ASTM D41
S Cap
Self -Adhering
Insta-Stik, 12-inch o.c.
-
IIJVB-3.
ASTM D41
rl S Cap
Self -Adhering
Millennium One Step Foamable Adhesive, 12-inch o.c.
-157.5
III,IVB-4.
ASTM D41
ThBuilt SA SBS Cap
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-S.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch o.c.
-290.0
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
IIII
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL36027-112
to of Authorization k9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
i by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516.1485 Appendix 1, Page 3 of 26
I
I
TRINITY I ERD
TABLE 1E-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER . `
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER i
System
I Base Sheet
Roof Cover (Note 15) j
MDP
No.
Deck (Note 1)
Base
Fasteners
Attach
Base Ply
Cap Ply
(Psf)
Min. 19/32-inch
Polyglass Elastobase, Polyglass Elastobase
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-Inch lap and 12-inch
(Optional) One or
W-1
plywood at max.
poly, Polyglass G2 Base, CertalnTeed
Roofgrip #14, Dekfast Hex with Dekfast #14
o.c. in two, equally spaced, staggered
more BP -AA or
SBS-AA, SBS-
-52.5
24-inch spans
Glasbaolyse, Firestone MB Base, JM Parma-
or TruFast MP-3 with TruFast HD
center rows
APP-TA
TA, APP•TA
Ply 28, Tamko Glass Base or GAFGLAS #75
Min. 19/32-Inch
Polyglass Elastobase or Polyglass
Dekfast Hex with Dekfast #14 or TruFast MP-
12-inch o.c. in 4-Inch lap and 12-Inch
One or more 585-
SBS-SA, APP-
W-2
plywood at max.
Elastobase Poly top
3 TruFast HD
o.c. In two, equally spaced, staggered
SA
SA, SBS-TA or
-52.5'
24-inch spans
with poly surface
with
center rows
APP-TA
Min. 19/32-Inch
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
12-inch o.c. In 4-inch lap and 12-Inch
(Optional) One or
SBS-AA, SBS-
W-3
plywood at max.
Elastobase Poly
Roofgrip #12
o.c. In two, equally spaced, staggered
more BP -AA or
TA, APP-TA
-60.0
24-inch spans
center rows
APP-TA
.Min. 19/32-Inch
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-Inch
One or more SBS-
SBS-SA, APP-
W-4
plywood at max.
Roofgrip #12
o.c. in two, equally spaced, staggered
SA
SA, SBS-TA or
-60.0'
24-Inch spans
Elastobase Poly with poly top surface
-
center rows
APP-TA
TABLE 1F: WOOD DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER q
System
Roof Cover (Note 15)
MOP
N
Deck
Prim
Joint Treatment
Base Ply
Ply
Cap Ply
(Psf)
-S
Min. 15/32-in plywood
(Optlona STM D41
None
SBS-SA
Optional)
(Optional) SBS-SA or
SBS-SA, APP-SA, SBS-TA
at max. 24-in h spans
APP-TA
or APP-TA
W-6
(Optional) ASTM D41
Plywood joints are covered with 4-inch wide strips of TriBuilt SA
TriBuilt SA SBS Base
(Optional) SBS-SA or
SBS-SA, APP-SA, SBS-TA
,-97.5
at max. 24-inch spans
SBS Base, rolled Into place to create continuous bond.
APP-TA
or APP-TA
Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516.1485 Appendix 1, Page 8of 26