Loading...
HomeMy WebLinkAbout99090151 ENERGY EFFICIENCY CODEi 41 Y BY 60OA-97 � . Lucie Cou* FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Pro'ect Name: 1890 - Cambridge - John LLoyd Bldrs Builder: John LLoyd Bldrs Ads ress: Lot: , Sub: Holiday Pines, Plat: Permitting Office: Cit , State: Sebastian, FL Permit Number: O �ler: Jurisdiction Number: Clirnate Zone: Central 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms t 5. Is this a worst case? 5. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b Clear - double pane c. Tint/other SC/SHGC - single pane d Tint/other SC/SHGC - double pane 8. Floor types a, Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a: Frame, Wood, Adjacent b. Frame, Wood, Exterior c: Concrete, Int Insul, Exterior d. N/A e. N/A 10. IlCeiling types New Single family _ 1 _ 3 _ No _ 2039 ft2 235.2 ft2 0.0 ft2 0.0 ft2 0.0 ft2 R=0.0, 246.0(p) ft R=11.0, 258.0 ft2 _ R=11.0, 414.0 ft2 R=4.2, 1209.0 ft2 a., Under Attic R=30.0, 1988.0 ft? b. Under Attic R=30.0, 74.0 ft2 _ c. N/A 11. Ducts _ a. Sup: Attic with RBS Ret: Con. AH: GarageSup. R=6.0, 50.0 ft b. /A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heafrecovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.12 Total as -built points: 28420.00 PASS Total base points: 29369.00 he4`eby certify that the plans and specifications covered by t iis calculation are in c a Florida En gy Code. D PR PARED BY: �Ic�io Caeecs D TE: 7113129 I he leby certify that this building, as designed, is in corr liance with the FI ida Energy Code. O NER/AGENT: o�.0 DA iE: Ck -\ c A Cap: 36.0 kBtu/hr SEER:10.00 _ Cap: 36.0 kBtu/hr COP: 1.00 _ Cap: 50.0 gallons EF: 0.96 Review of the plans and ,T s?' specifications covered by this tio� calculation indicates compliance with the Florida Energy Code. Before construction is completed 0 j a this building will be inspected for n compliance with Section 553.908 CODS Florida Statutes. BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) F(3 60OA-97 . SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I J�DDRESS: Lot: , Sub: Holiday Pines, Plat: , Sebastian, FL, PERMIT #: BASE AS -BUILT G ASS TYPES .1 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .1 1 2039.0 42.08 15443.3 Single, Clear N 1.5 5.0 46.4 27.96 0.92 1190.5 Single, Clear N 1.5 5.0 23.2 27.96 0.92 595.3 Single, Clear N 4.5 2.0 6.0 27.96 0.63 105.7 Single, Clear N 1.5 7.5 23.2 27.96 0.96 623.9 Single, Clear N 1.5 3.0 9.1 27.96 0.84 213.1 Single, Clear W 1.5 2.0 6.7 53.47 0.62 220.4 Single, Clear S 1.5 5.5 32.4 44.66 0.85 1225.8 Single, Clear S 1.5 5.5 32.4 44.66 0.85 1225.8 Single, Clear S 1.5 5.5 16.2 44.66 0.85 612.9 Single, Clear E 1.5 2.5 13.5 59.31 0.68 541.9 Single, Clear E 1.5 3.0 9.9 59.31 0.74 432.5 Single, Clear E 1.5 5.5 16.2 59.31 0.90 865.5 As -Built Total: 235.2 7853.4 W LL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Ad lcent 258.0 0.7 180.6 Frame, Wood, Adjacent 11.0 258.0 0.70 180.6 Exterior 1623.0 1.90 3083.7 Frame, Wood, Exterior 11.0 414.0 1.90 786.6 Concrete, Int Insul, Exterior 4.2 1209.0 1.16 1402.4 Ba a Total: 1881.0 3264.3 As -Built Total: 1881.0 12369.6 D OR TYPES Area X BSPM = Points Type Area X SPM = Points Adj cent 18.0 1.60 28.8 Exterior Insulated 20.0 4.80 96.0 ExI nor 105.0 4.80 504.0 Exterior Insulated 17.0 4.80 81.6 Exterior Insulated 17.0 4.80 81.6 Exterior Insulated 17.0 4.80 81.6 Exterior Insulated 17.0 4.80 81.6 Exterior Insulated 17.0 4.80 81.6 Adjacent Insulated 18.0 1.60 28.8 Ba a Total: 123.0 532.8 As -Built Total: 123.0 532.8 C LING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Uni er Attic 2039.0 0.60 1223.4 Under Attic 30.0 1988.0 0.60 11192.8 Under Attic 30.0 74.0 0.60 44.4 Ba a Total: 2039.0 1223.4 As -Built Total: 2062.0 1237.2 Eller gyGauge@ DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details • � I (ADDRESS: Lot: , Sub: Holiday Pines, Plat: , Sebastian, FL, PERMIT #: BASE AS -BUILT FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Sla 246.0(p) -31.8 -7822.8 Slab -On -Grade Edge Insulation 0.0 246.0(p) -31.90 -7847.4 Rai'5ed 0.0 0.00 0.0 Ba a Total: -7822.8 As -Built Total: -7847.4 IN ILTRATION Area X BSPM = Points Area X SPM = Points 2039.0 14.31 29178.1 2039.0 14.31 29178.1 S �mmer Base Points: 41819.1 Summer As -Built Points: 32952.5 T ,Ital Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 32952.5 1.000 1.030 0.341 1.000 11573.9 �1819.1 0.3577 14958.7 32952.5 1.00 1.030 0.341 1.000 11573.9 Tm DCA Form 60OA-97 EnergyGauge®IFIaRES'97 FLRCNA-200 FORM 600A-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details • I JPDDRESS: Lot: , Sub: Holiday Pines, Plat: , Sebastian, FL, PERMIT #: BASE AS -BUILT Gl. SS TYPES 1 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .1 2039.0 4.79 1757.9 Single, Clear N 1.5 5.0 46.4 12.32 1.00 569.5 Single, Clear N 1.5 5.0 23.2 12.32 1.00 284.7 Single, Clear N 4.5 2.0 6.0 12.32 0.98 72.8 Single, Clear N 1.5 7.5 23.2 12.32 1.00 285.1 Single, Clear N 1.5 3.0 9.1 12.32 0.99 111.4 Single, Clear W 1.5 2.0 6.7 10.74 1.07 77.0 Single, Clear S 1.5 5.5 32.4 7.73 1.06 266.5 Single, Clear S 1.5 5.5 32.4 7.73 1.06 266.5 Single, Clear S 1.5 5.5 16.2 7.73 1.06 133.3 Single, Clear E 1.5 2.5 13.5 9.96 1.08 145.5 Single, Clear E 1.5 3.0 9.9 9.96 1.06 104.7 Single, Clear E 1.5 5.5 16.2 9.96 1.02 164.8 As -Built Total: 235.2 , 2481.8 Wj LL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Ad 'cent 258.0 1.8 464.4 Frame, Wood, Adjacent 11.0 258.0 1.80 464.4 Exi nor 1623.0 2.00 3246.0 Frame, Wood, Exterior 11.0 414.0 2.00 828.0 Concrete, Int Insul, Exterior 4.2 1209.0 3.26 3941.3 Ba a Total: 1881.0 3710.4 As -Built Total: 1881.0 15233.7 D OR TYPES Area X BWPM = Points Type Area X WPM = Points Adj acent 18.0 4.00 72.0 Exterior Insulated 20.0 5.10 102.0 Exterior 105.0 5.10 535.5 Exterior Insulated 17.0 5.10 86.7 Exterior Insulated 17.0 5.10 86.7 Exterior Insulated 17.0 5.10 86.7 Exterior Insulated 17.0 5.10 86.7 Exterior Insulated 17.0 5.10 86.7 Adjacent Insulated 18.0 4.00 72.0 Ba a Total: 123.0 607.5 As -Built Total: 123.0 607.5 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Uni er Attic 2039.0 0.60 1223.4 Under Attic 30.0 1988.0 0.60 ' 1192.8 Under Attic 30.0 74.0 0.60 44.4 Ba a Total: 2039.0 1223.4 As -Built Total: 2062.0 1237.2 E ergyGauge® DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 60OA-97 WINTER CALCULATIONS `jj Residential Whole Building Performance Method A - Details • ; �4DDRESS: Lot: , Sub: Holiday Pines, Plat: ,Sebastian, FL, PERMIT #: BASE AS -BUILT FLOOR OR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slat: Raid Base Total: 246.0(p) -1.9 0.0 0.00 -467.4 0.0 -467.4 Slab -On -Grade Edge Insulation As -Built Total: 0.0 246.0(p) 2.50 615.0 615.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 2039.0 -0.28 -570.9 2039.0 -0.28 -570.9 Wi ter Base Points: 6260.8 Winter As -Built Points: 9418.7 Toal Winter X Points System = Heating Multiplier Points Total X Cap X Component Ratio Duct X System X Multiplier Multiplier Credit Multiplier = Heating Points 260.8 1.0730 6717.9 9418.7 1.000 9418.7 1.00 1.040 1.000 1.040 1.000 1.000 1.000 9795.5 9795.5 Tm DCA Form 60OA-97 EnergyGauge@/FIaRES'97 FLRCNA-200 FORM 600A-97 WATER HEATING & CODE COMPLIANCE STATUS • Residential Whole Building Performance Method A - Details • • I (ADDRESS: Lot: , Sub: Holiday Pines, Plat: , Sebastian, FL, PERMIT #: BASE AS -BUILT W44ER HEATING I N tuber of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bidrooms 11 Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 50.0 0.96 3 1.00 2350.33 1.00 7051.0 As -Built Total: 7051.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling . + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total oints Points Points Points Points Points Points Points 14958.7 6717.9 7692.0 29368.E 11573.9 9795.5 7051.0 28420.4 PASS '�y04'S8E STAT�o�� X X X DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 FO M 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details • , DDRESS: Lot: , Sub: Holiday Pines, Plat: , Sebastian, FL, PERMIT #: 6 1-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST PONENTS SECTION for Windows & Doors 606.1.ABC.1.1 for & Adjacent Walls 606.1.ABC.1.2.1 606.1.ABC.1.2.2 606.1.ABC.1.2.3 Rooessed Lighting Fixtures 1606.1.ABC.1.2.4 Mi Iti-story Houses 606.1.ABC.1.2.5 Ac itional Infiltration reqts 606.1.ABC.1.3 REQUIREMENTS FOR EACH PRACTICE CHECK Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Air barrier on perimeter of floor cavity between floors. Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OT14FR PRESCRIPTIVE MF_A.R1JRFS /mnc4 ha mat nr avd-aarlarl by all racielaneac 1 COMPONENTS SECTION REQUIREMENTS CHECK W ter Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Siimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Sil ower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Ai Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. H1 AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. In ulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. TPA DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 1. 2. 3. 4. 5. 6. 7. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 82.1 The higher the score, the more efficient the home. , Lot: , Sub: Holiday Pines, Plat: , Sebastian, FL, New construction or existing New Single family or multi -family Single family _ Number of units, if multi -family 1 Number of Bedrooms 3 Is this a worst case? No _ Conditioned floor area (ft2) 2039 ft2 Glass area & type Clear - single pane 235.2 ft2 _ Clear - double pane 0.0 ft2 Tint/other SC/SHGC - single pane 0.0 ft2 _ Tint/other SC/SHGC - double pane 0.0 ft2 Floor types Slab -On -Grade Edge Insulation R=0.0, 246.0(p) ft _ N/A _ N/A Wall types Frame, Wood, Adjacent R=11.0, 258.0 ft2 _ Frame, Wood, Exterior R=11.0, 414.0 ft2 _ Concrete, Int Insul, Exterior R=4.2, 1209.0 ft2 _ N/A _ N/A Ceiling types Under Attic R=30.0, 1988.0 ft2 _ Under Attic R=30.0, 74.0 ft2 N/A Ducts Sup: Attic with RBS Ret: Con. AH: GarageSup. R=6.0, 50.0 ft N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) I c rtify that this home has complied with the Florida Energy Efficiency Code For Building C struction through the above energy saving features which will be installed (or exceeded) in 1his home before final inspection. Otherwise, a new EPL Display Card will be completed b ed on installed (Nde compliant features. B�lder Signature: c ���� Date: of New Home: SRO c� �c�oQv+�sz �y �� City/FL Zip: Cap: 36.0 kBtu/hr SEER:10.00 _ Cap: 36.0 kBtu/hr COP: 1.00 Cap: 50.0 gallons _ EF: 0.96 TE: The home's estimated energy performance score is only available through the FLARES computer program. is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStarTmdesignation), home may qualms for energy efficiency mortgage (EEAI) incentives ifyou obtain a Florida Energy Gauge Rating. act the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for oration and a list of certifted Raters. For information about Florida's Energy Efficiency Code For Building Construction, tct the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) BUILDING INPUT SUMMARY REPORT Title: 1890 - Cambridge - John LLoyd Elkhmily Type: Single Address Type: Lot Information F- Owner: (blank) New/Existing: New Lot #: (blank) # of Units: 1 Bedrooms: 3 Subdivision: Holiday Pines LLI Name: John LLoyd Bldrs Conditioned Area: 2039 Platbook: (blank) OBuilder 0 Climate: Central Total Stories: 1 Street: N/A 12 Permit Office: (blank) Worst Case: No County: (blank) Jurisdiction #: (blank) Rotate Angle: (blank) City, St, Zip: Sebastian, FL, CO)11 # Floor Type R-Val Area/Perimeter Units N # Door Type Orientation Area 1 Slab -On -Grade Edge Insulation 0.0 246.0(p) ft 1 1 Insulated Exterior 20.0 ft2 W W O 2 Insulated Adjacent 18.0 ft2 O Insulated Exterior 17.0 ft2 ,J 03 4 Insulated Exterior 17.0 ft2 LL 3 Other(s) - 51.0 ft2 U# Ceiling Type R-Val Area Base Area Units # System Type Efficiency 1 Under Attic 30.0 1988.0 ft2 1983.0 ft2 1 1 Central Unit SEER: 10.00 Z Z 2 Under Attic 30.0 74.0 ft2 56.0 ft2 1 J _J. W OO V # Wall Type Location R-Val Area Units Credit Multipliers: ARB 1 Frame - Wood Adjacent 11.0 258.0 ft2 1 # System Type Efficiency J 2 Frame - Wood Exterior 11.0 414.0 ft2 1 0 1 Electric Strip COP: 1.00 3 Concrete Block - Int Insul Exterior 4.2 1209.0 ft2 1 Z 7 Q LLI = Credit Multipliers: None # Panes Tint Ornt Area OH Length OH Hght Units # Supply Return Air Handler Supply 1 Single Clear 9 N 23.2 ft2 1.5 ft 5.0 ft 2 (/i Location Location Location R-Val 2 Single Clear N 23.2 ft2 1.5 ft 5.0 ft 1 H 1 Uncond. Cond. Garage 6.0 3 Single Clear N 6.0 ft2 4.5 ft 2.0 ft 1 L) 4 Single Clear N 23.2 ft2 1.5 ft 7.5 ft 1 5 Single Clear N 9.1 ft2 1.5 ft 3.0 ft 1 Q Units Capacity 36.0 kBtu/hr Capacity 36.0 kBtu/hr 50.0 ft 6 Single Clear W 6.7 ft2 1.5 ft 2.0 ft 1 7 Single 8 Single Clear Clear S S 16.2 ft2 16.2 ft2 1.5 ft 1.5 ft 5.5 ft 5.5 ft 2 2 # System Type EF Cap. Conservation Type Con. EF 9 Single Clear S 16.2 ft2 1.5 ft 5.5 ft 1 LLJ 1 Electric Resistance 0.96 50.0 None 0.00 10 Single Clear E 13.5 ft2 1.5 ft 2.5 ft 1 11 Single Clear E 9.9 ft2 1.5 ft 3.0 ft 1 Q 12 Single Clear E 16.2 ft2 1.5 ft 5.5 ft 1 # Use Default? Annual Operating Cost Electric Rate 02 1 Yes N/A N/A LL LLI W Rater Name: (blank) Class #: 3 Pool Size: 0 V Rater Certification #: (blank) Duct Leakage Type: N/A Pump Size: 0.00 hp V) Area Under Fluorescent: 0.0 Visible Duct Disconnects: N/A Dryer Type: Electric , Area Under Incandescent: 0.0 Leak Free Duct System Proposed: No Stove Type: Electric HRV/ERV System Present?: Avg Cell Hgt: EnergyGauge® (Version: FLRCNA-200) Summary Energy Code Results Residential Whole Building Performance Method A Project Title: Class 3 Rating 1890 - Cambridge - John LLoyd Bldrs Registration No. 0 n, FL Climate: Central 7/13/99 Building Loads Base As -Built Summer: 41819 points Summer: 32953 points Winter: 6261 points Winter: 9419 points Hot Water: 6769 points Hot Water: 6769 points Total: 54849 points Total: 49140 points Energy Use Base As -Built Cooling: 14959 points Cooling: 11574 points Heating: 6718 points Heating: 9795 points Hot Water: 7692 points Hot Water: 7051 points Total: 29369 points Total: 28420 points PASS e-Ratio: 0.97 EnergyGauge@(Version: FLRCNA-200) 0 7-12-99 /N RSR20851 _ RIGHT-J SHORT FORM }le name: JLCAMB- 1. RSR #: COTTON-CAMBRIDGE Htg Clg Qb or: JOHN LLOYD BUILDERS, INC. Outside db 42 90 Inside db 70 75 • Design TD 28 15 Daily Range - M Inside Humid. - 50 • y: ARNOLD AIR CONDITIONING, INC. Grains Water - 62 847 FELLSMERE HWY. Method Simplified SEBASTIAN FL 32958 Const. glty Average 5 8 9-10 6 3 Fireplaces 1 HEATING EQUIPMENT COOLING EQUIPMENT ake GOODMAN Make GOODMAN rade JANITROL Trade JANITROL 48-15 CK49-1 fficiency 100.0 AFUE Efficiency 10.0 EER eating Input 51000 Btuh Sensible Cooling 31500 Btuh eating Output 51000 Btuh Latent Cooling 13500 Btuh eating Temp Rise ' 22 Deg F Total Cooling 45000 Btuh dual Heating an 2140 CFM Actual Cooling Fart 2140 CFM • tg Air Flow Factor 0.060 CFM/Btuh Clg Air Flow Factor 0.053 CFM/Btuh pace Thermostat WH I TEROGERS Load Sensible Heat Ratio 86 ROOM NAME AREA HTG CLG HTG CLG SQ.FT. BTUH BTUH CFM CFM OYER 20 1617 1284 97 69 • BATH 266 4536 4148 272 222 . BEDROOM 280 5759 6409 346 343 IVING ROOM 266 3930 6392 236 342 OOK 54 1547 1999 93 107 ITCHEN 196 187 1496 11 80 AMILY ROOM 364 8962 9635 53.8 515 ATH 65 1215 644 73 34 EDROOM 2 144 1730 860 104 46 UNDRY 96 743 1599 45 85 EDROOM 3 144 3357 2943 202 157 INING ROOM i 144 2038 2609 122 140 ntire House d 2039 35622 40019 2140 2140 entilation Air 0 0 quip.@ 0.95 RSM 38018 atent Cooling 6375. TOTALS 2039 35622 44393 2140 2140 MANUAL J: 7th Ed. Right -Suite: V4.1.27 ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT • 2300 VIRGINIA AVENUE, ROOM 201 FT. PIERCE, FL. -34982-5652 407-462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all appl tions for building permit Involving the construction of new residence (single or multi -family), residential addition. any accessory stru , ure requiring a building permit, and any nonresidential structure. This Certification shall not apply to Interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assik ance, please contact the Building Inspection Office at 462-1553 or 462-2172. r NAME _ z o ADDRESSJ \ loom:::.:.:,<. Ci QCIv 6 PR NUMBER PERMIT NUMBER OCCP. TYPE CST. TYPE 15tRTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HA E BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CU RENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL EL MENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FO i CES SPECIFIED BY CURRENT CODE PROVISIONS. 1. 2. 3. ti. 6. 7. a. 9. 10. 12. 13.1 BUILDING CODE EDITION USED (YEAR) SBCCI ASCE 7-:6ig5 _k� OTHER(SPECIFY) BUILDING DESIGN IS (cFECK oW ENCLOSED I/ PARTIALLY ENCLOSED OPEN BUILDING BUILDING HEIGHT: ��_ FT 4. WIND SPEED USED IN BUILDING DESIGN: ��_ MPH WIND EXPOSURE CLASSIFICATION (REFER To EXPOSURE TABLES IN BIDDING CODE MENrIMED IN LINE •I): AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: • �L�_'_'7` PSF PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE _ �"17. O PSF IMPORTANCE/USE FACTOR (OBTAIN FROM k"NG CODE): --T— ' LOADS: FLOOR O PSF ROOFIDEAD: PSF ROOF/LNE: � (C� PSF WERE SHEAR WALLS CONSIDERED FOR STRUCTURE HECK OW YES '� NO H N , wtj? (attach explanation) IS A CONTINUOUS LOAD PATH PROVIDED ((>ECK oNE) evianation) ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK oM explanation) MINIMUM SOIL BEARING PRESSURE PSF WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT l TIFICATION IS TRUE AND CORRECT I,- TO THE BEST OF MY d CATION N ON FIRM: ENGINEERING AND TESTING, SEBAS-rlAfqFL 32 978-1377 Ind'an River 511:: , ' revard 768-8488 YES _� NO it NO, why? (attach YES 'f NO If NO, why? (attach ir*